Specifying an SMP Gateway
Contents
1. Specifying an SMP Gateway 2006 07 10 Pa cybectec www cybectec com Quebec City 730 Commerciale Street Suite 200 Saint J ean Chrysostome Quebec Canada G6Z 2C5 Telephone 418 834 0009 Fax 514 227 5256 Montreal 1290 St Denis Street Suite 400 Montreal Quebec Canada H2X 3J7 Telephone 514 845 6195 Fax 514 227 5256 2006 07 10 Contents ContentS sssseeeeeeeea naaa a nenen kee a ana aa Kanan naaa Kana KEEK a a KEK anna aa Kanan nana i Specifying an SMP Gateway cssscsssccssssensseecsnsseneeseeeeseenseeneseneassenesseneseeneesenenes 1 Selecting the SMP Gateway Model x ssseeeeeaaaa anna anna anna anna nana nana naa naaa 1 Specifying SMP 4 Options cccssccsssecssseecseseennseeneeeeeeneeeneasenaeeeeneeeneaeeeeeeseneesensaes 5 Specifying SMP 16 CP and SMP 16 SG Options csssscssssecsesseenseeesneseneseeneeensaes 7 Specifying Redundant SMP csssccsssscsessensseceesseneeeeeeeesennseeneeseeneseenseennaeseneeeenss 10 Specifying SMP Software Options ccsssccssscssssecseeeesnseeonssenensseneseeneaseonsseneesenss 11 Documentation ssssssssssssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnannnnnnnnnnnnn annann nna 14 Training Si TTT TT 15 SMP Warranty and Maintenannce ceseeeecseseeeeeeneseeeeennaeeeseneaseeseeaeeessanaeeenanoas 16 SPECIFYING AN SMP GATEWAY i 2006 07 10 Specifying an SMP Gateway To assist you in using the accompanying price list we
2. gt Continue to Specifying SMP Software Options page 11 10 SPECIFYING AN SMP GATEWAY 2006 07 10 Specifying SMP Software Options All SMP models are provided with a CD containing SMP software PC based tools and complete documentation Before using the SMP you must select the device protocols control center protocols and software options that you intend to use Using this information Cybectec will provide you with an activation key that will allow you to create the specific software configuration for each SMP The SMP 16 CP and SMP 16 SG share a common licensing model that is based on the master and slave protocols to use The SMP 4 licensing model is different and is based on the number of connections as explained further on Specifying Master and Slave Protocols Master protocols are used to communicate with devices Slave protocols are used to communicate with control centers When specifying an SMP Gateway you must purchase a license for each master and slave protocol that will be used Both types of protocols are different and must be purchased separately Standard protocols can generally be used to communicate with devices from different manufacturers For instance the MODBUS protocol is quite common in the automation industry and can be used to communicate with a large variety of devices from different manufacturers Proprietary protocols are often limited to a specific device model For instance all SEL
3. you should specify an SMP 4 Mini Gateway The SMP 4 data concentrator can connect up to 8 devices to a single control center The purchase price includes a master and a slave protocol license If all devices use the same protocol no additional protocol licenses are required If different protocols are used you must purchase a master protocol license for each additional protocol P SSMP 5101 SMP 4 master protocol license Provides the SMP 4 data concentrator and SMP 4 mini gateway with the capability to use an additional master protocol The SMP 4 Mini Gateway can connect up to 16 devices to 4 different control centers The purchase price includes a master and a slave protocol license If all devices use the same protocol no additional protocol licenses are required If different protocols are used you must purchase a master protocol license for each additional protocol In the same manner if different protocols are used for the control centers you must purchase a slave protocol license for each additional protocol P SSMP 5102 SMP 4 slave protocol license Provides the SMP 4 Mini Gateway with the capability to use an additional slave protocol Note While an SMP 4 protocol license provides the capability to use any of the available protocols Cybectec requests that your orders specify the protocols that will be used This information will help us complete your customer profile and provide the best service possible Specify Software
4. 264 VAC 105 370 VDC power supply standard P PUPG 0303 18 36 VDC power supply P PUPG 0302 36 75 VDC power supply Add Optical Ethernet Interfaces if Required The SMP 16 optical Ethernet interfaces are internally mounted on a small piggyback board that includes a PCMCIA PC CARD adaptor P POPT 1601 Dual optical interface for SMP 16 Dual 100 Mbps optical interface for 1300 nm multimode fiber with ST full duplex connectors Includes adaptor for one PCMCIA card For SMP 16 CP and SMP 16 SG Add the Internal GPS Clock if Required Both the SMP 16 CP and SMP 16 SG models support an optional internal GPS clock With this option the SMP can synchronize its internal clock and distribute an IRIG clock to all connected devices This option is not field installable and must be specified at time of purchase P POPT 1602 GPS clock for SMP 16 Factory installed GPS clock with 0 083 second accuracy Requires cable antenna amplifier and surge protection to be purchased separately Operation of the clock requires the addition of an antenna mounting bracket and surge suppressor The GPS clock has been tested to provide the best quality of reception with the recommended antenna using RG 8 cable Substitution is not recommended SPECIFYING AN SMP GATEWAY 7 2006 07 10 POPT 1616 POPT 1619 POPT 1613 GPS active antenna kit for the SMP 16 GPS Clock Active outdoor bullet III antenna with TNC connector includes 82 ft 25 m of RG 8
5. Options The following software options are available for all models of the SMP unless otherwise indicated To simplify configuration and commissioning you should always specify the Web Server and Passthru options SPECIFYING AN SMP GATEWAY P SSMP 0101 P SSMP 0301 P SSMP 0201 P SSMP 0501 P SSMP 0603 P SSMP 0701 SPECIFYING AN SMP GATEWAY 2006 07 10 Embedded SMP Web server Provides access to SMP real time and maintenance data using a standard web browser Passthru support Used to establish a transparent connection between programs running on a PC and any device connected to the SMP Soft PLC engine Provides the SMP with the capability to run automation scripts developed with the CoDeSys IEC 61131 3 workbench Not available for SMP 4 model SNMP agent Allows an SNMP manager to poll the SMP for statistics link up alarms link down alarms SMP reset alarms Supports SMP reset and statistic reset Automation function package Comprehensive set of logic and group operations for the SMP Gateway Modem support Adds the capability to establish a dialup connection to remote devices and control centers Required to use an external modem or the SMP 4 SMP 16 CP or SMP 16 SG internal modem 13 2006 07 10 Documentation All SMP Gateways are provided with all the required software and documentation on CD Printed documentation can be ordered separately or in combination with the console port cable in the SM
6. a slave to process polling requests One day Must be combined with Using the SMP Gateway training The following course is recommended before using the built in automation functions or the Soft PLC options P TTRN 0102 SPECIFYING AN SMP GATEWAY SMP automation functions training Implementing substation automation applications using the gateway s built in automation functions and the Soft PLC Basic SMP training is prerequisite 15 2006 07 10 SMP Warranty and Maintenance SMP 4 SMP 16 CP and SMP 16 SG Cybectec will promptly replace or repair any device that fails during a period of 5 years after delivery SMP Software and Tools During a period of 18 months after delivery or 12 months after installation whichever occurs first Cybectec will correct any software problem that prevents the system from meeting stated customer requirements Technical Support The basic warranty includes free technical support from our engineering staff for up to 5 incidents during a period of 18 months after delivery or 12 months after installation Questions and problems can be submitted by the designated customer contact by email fax or phone during our normal business hours 8 AM to 5 PM EST Warranty Extension Maintenance Plan and Engineering Support The basic SMP warranty and support can be extended using one of the following options P TWAR 0101 SMP warranty extension plan The SMP warranty extension plan ensures that your SMP
7. have put together the following guidelines that will help you select the appropriate options when specifying an SMP Selecting the SMP Gateway model Selecting the hardware options Selecting the software options Selecting the protocols Selecting training warranty and support options Selecting the SMP Gateway Model With few exceptions all models of the SMP Gateway share the same software capabilities The differences between the models are mostly hardware and applications developed on one model can generally be ported to another with minimal configuration effort The SMP 4 is the low cost solution for small substations and distribution automation projects It supports all of the software capabilities of the SMP Gateway except redundancy and the Soft PLC It provides a single Ethernet port 3 RS 232 serial ports and 1 universal RS 232 422 485 serial port An optional internal modem can replace one of the RS 232 ports The SMP 16 CP sets the standard for substation gateways It offers 16 universal serial ports 2 metallic or optical Ethernet ports IRI G B redistribution and optional GPS clock The SMP 16 SG adds expansion capabilities to the SMP 16 It supports up to two expansion modules The serial port module adds 16 universal serial ports to the SMP Gateway providing a capability of up to 48 serial ports The Ethernet Switch module provides metallic and Ethernet connectivity for the substation without requiring the use of an ext
8. the Configuration The SMP 4 is available in 3 different configurations according to the number of devices and control centers to be connected Select the required configuration P PSMP 0403 SMP 4 protocol translator configuration One to one Connects 1 device to one 1 control center Includes 1 Master and 1 Slave protocol licenses P PSMP 0402 SMP 4 data concentrator configuration Many to one Connects a maximum of 8 devices to 1 control center Includes 1 Master and 1 Slave protocol licenses P PSMP 0404 SMP 4 mini gateway configuration Many to many Connects a maximum of 16 devices to a maximum of 4 control centers Includes 1 master and 1 slave protocol licenses An SMP 4 configuration can be upgraded at a later time by purchasing one of the following upgrades P SSMP 5001 SMP 4 protocol translator to data concentrator Adds the capability to support up to 8 devices P SSMP 5002 SMP 4 protocol translator to mini gateway Adds the capability to support up to 16 devices and 4 control centers P SSMP 5003 SMP 4 data concentrator to mini gateway Adds the capability to support up to 16 devices and 4 control centers Specify the Power Supply P PUPG 0403 85 264 VAC 110 370VDC power supply for SMP 4 standard P PUPG 0405 9 18 VDC power supply for SMP 4 P PUPG 0402 18 72 VDC power supply for SMP 4 SPECIFYING AN SMP GATEWAY 5 2006 07 10 Specify the Hardware Options The only hardware option available for the S
9. to 32 or 48 serial universal ports P POPT 1603 Serial ports module for SMP 16 SG Adds 16 universal RS232 422 485 serial ports to the SMP 16 SG Distributes demodulated IRIG B to each port The SMP 16 SG Ethernet switch modules provide substation grade Ethernet connectivity in metallic fiber optic or mixed configurations One of the built in ports of the SMP SPECIFYING AN SMP GATEWAY 2006 07 10 16 SG must be connected to the switch module using the provided cable as if it were an external switch The P POPT 1601 dual optical interface option is required to connect the SMP 16 SG to the P POPT 1610 fiber optic switch module P POPT 1605 Ethernet switch module with 16 10 100Base T ports Adds 16 10 100Base T ports to the SMP 16 SG RJ 45 connectors Includes P CABC 1601 11 8 in 30 cm RJ 45 cable P POPT 1610 16 port fiber optic Ethernet switch module Adds 16 100Base FX ports to the SMP 16 SG LC connectors Includes P CABC 1602 30 cm ST to LC fiber optic cable P POPT 1611 16 port fiber optic plus metallic Ethernet switch module Adds 8 100Base FX ports with LC connectors and 8 10 100Base T ports with RJ 45 connectors to the SMP 16 SG Includes P CABC 1601 11 8 in 30 cm RJ 45 cable Cabling In order to configure the networks settings of the SMP 16 and load the firmware you will need to connect it to a PC using a standard DB 9M to DB 9F cable P CABC 0107 DB 9M to DB 9F console port cable Used to connect all SMP m
10. MP 4 is an internal modem which replaces one of the 3 RS 232 serial ports With the modem option installed the SMP 4 provides 1 RS 232 422 485 and 2 RS 232 serial ports This option is not field installable and must be specified at time of purchase P PUPG 0404 Internal 33 6 Kbps V 34 Modem Replaces one RS 232 serial port Adds the capability to establish a dialup connection to remote devices and control centers Requires P SSMP 0701 modem support software Cabling In order to configure the networks settings of the SMP 4 and load the firmware you will need to connect it to a PC using a standard DB 9M to DB 9F cable P CABC 0107 DB 9M to DB 9F console port cable Used to connect all SMP models to a PC Required for initial system configuration and loading of SMP firmware gt Skip to Specifying SMP Software Options page 11 6 SPECIFYING AN SMP GATEWAY 2006 07 10 Specifying SMP 16 CP and SMP 16 SG Options Specify the SMP 16 CP Configuration The basic SMP 16 CP configuration can connect up to 16 devices to a maximum of 2 control centers using any combination of RS 232 RS 422 RS 485 or TCP IP connections The SMP 16 CP additional connectivity option raises this capability to 128 devices and 64 control centers P SSMP 5201 SMP 16 CP additional connectivity option Adds to SMP 16 CP the capability to connect to a maximum of 128 devices and a maximum of 64 control centers Specify the Power Supply P PUPG 0301 85
11. P Starter Kit P DPRN 0102 Printed SMP documentation SMP Gateway user manual covers all SMP models P DPRN 0103 SMP starter kit Includes P DPRN 0102 printed SMP documentation and P CABC 0107 DB 9M to DB 9F console port cable 14 SPECIFYING AN SMP GATEWAY Training 2006 07 10 The SMP Gateway is a complex product You should always plan for basic training in order to help you make the most out of your SMP Gateway While the SMP is provided with first quality documentation the following basic course should be considered a prerequisite to getting started P TTRN 0101 Using the SMP Gateway training Basic SMP Gateway training Covers principles of operation applications setting up the gateway configuring master and slave protocols Two days The following courses can be combined with the basic SMP Gateway training to provide additional protocol knowledge and experience P TTRN 0106 P TTRN 0107 Using the DNP3 protocol training Expands on the protocol knowledge presented in the basic SMP training Covers advanced functions and data types event classes configuring a master to poll a device configuring a slave to process polling requests One day Must be combined with Using the SMP Gateway training Using the IEC 60870 5 101 103 104 protocol training Expands on the protocol knowledge presented in the basic SMP training Covers advanced functions and data types configuring a master to poll a device configuring
12. abilities 4 USB ports 1 VGA output 1 x PCCARD for custom requirements 1 or 2 expansion modules Serial port expansion module 16 RS 232 422 485 16 port Ethernet switch 10 100Base T and or 100Base FX SPECIFYING AN SMP GATEWAY 2006 07 10 SMP 4 SMP 16 CP SMP 16 SG Features Real time clock with Yes battery backup Built in watchdog timer Yes power supply monitoring Built in self diagnostics Yes Passthru connections Yes Built in web server Yes Dialup connections Yes Automation functions Yes Windows based Yes configuration and maintenance tools Redundancy support for No Yes mission critical applications Soft PLC No Yes Supported Protocols DNP3 IEC 60870 5 101 103 104 MODBUS SEL GE ABB L amp G COOPER and most electrical industry proprietary protocols IEC 61850 UCA 2 0 and ICCP Limits Maximum device connections master connections 1 8 or 162 16 or 1283 128 Maximum control center connections slave connections lor 4 2 or 64 64 Maximum data points 5 000 10 000 1 Maximum number of individual devices managed by the SMP connected directly by a multi drop link or by network connection 2 1 with protocol converter configuration 8 with data concentrator configuration and 16 with mini gateway configuration 3 16 with basic configuration 128 wit
13. and its accessories will promptly be replaced with a pre configured unit in the event of a hardware failure P TMNT 0101 SMP maintenance plan The SMP maintenance plan provides continuous access to the latest version of the gateway software and of the PC based configuration and maintenance tools The plan also ensures unlimited access to our technical support staff to assist in you using the tools to configure your SMP P TENG 0101 SMP engineering support plan The SMP engineering support plan provides you with access to our technical support staff to assist you with your automation project 16 SPECIFYING AN SMP GATEWAY
14. cable with TNC connectors at both ends Mounting bracket P POPT 1619 and surge suppressor P POPT 1613 required Mounting bracket for GPS antenna Variable angle mounting bracket include 0 75 in 1 9 cm diameter 14 thread per 1 in 2 54 cm support pole Surge suppressor kit for SMP 16 GPS clock Includes surge suppressor and 6 5 ft 2 m cable with TNC connectors at both ends The GPS antenna is provided with 82 ft 25 m of RG 8 cable Cable lengths in excess of 25 m require an inline amplifier Custom cable lengths can be ordered as well as the connectors and tool necessary to assemble the cable POPT 1615 POPT 1617 POPT 1618 POPT 1620 Inline amplifier kit for SMP 16 GPS Clock Includes 20 dB in line amplifier and 19 7 in 50 cm cable with TNC connectors at both ends Required if antenna cable length exceeds 82 ft 25 m RG 8 GPS antenna cable custom length RG 8 cable without connectors Requires P POPT 1618 crimping tool Price per meter minimum length of 39 in 1 m Crimping tool for TNC connectors Includes 4 TNC connectors TNC connector for RG 8 cable Price per connector 2 connectors per cable required P POPT 1618 crimping tool required for assembly Specify SMP 16 SG Expansion Modules The SMP 16 SG supports two expansion modules which can be used to add serial ports or the Ethernet switch module One or two P POPT 1603 serial ports modules can be added to extend the SMP 16 SG capability
15. device protocols are slightly different and you will need to purchase different protocol licenses for different models such as SEL 321 SEL 351 and SEL 421 The first SEL protocol is sold at the indicated price additional SEL protocols are discounted 50 SEL protocol licenses are now available in bundles of 5 10 or 20 different protocols The selected protocols must be specified at the time of the order P RPKG 1001 SEL master protocol 5 pack Support five different SEL master protocols Protocols must be selected at time of purchase P RPKG 1002 SEL master protocol 10 pack Support ten different SEL master protocols Protocols must be selected at time of purchase P RPKG 1003 SEL master protocol 20 pack Support twenty different SEL master protocols Protocols must be selected at time of purchase Note The ICCP protocol is not available for the SMP 4 model SPECIFYING AN SMP GATEWAY 11 2006 07 10 12 Note Configuration of UCA 2 0 IEC 61850 and ICCP protocols is complex and Cybectec engineering support is recommended The SMP 4 Licensing Model The SMP 4 licensing model is based on the number of devices control centers and protocols used The SMP 4 protocol translator can connect a single device to a single control center The purchase price includes a master and a slave protocol license If more devices are required you should specify an SMP 4 Data Concentrator If additional control centers connections are required
16. ernal switch The SMP 4 20 and SMP 8 40 remain available and Cybectec will continue to support these models for existing customers The following table summarizes the features of each model SPECIFYING AN SMP GATEWAY 1 2006 07 10 SMP 4 SMP 16 CP and SMP 16 SG Specifications VDC 85 264 VAC 110 370 VDC SMP 4 SMP 16 CP SMP 16 SG Physical Height 1 77 45 mm 5 22 132 6 mm 3U Width 4 27 108 5 mm 19 482 6 mm Length 6 3 160 mm 11 02 280 mm Power Supply Range 9 18 VDC 18 72 18 36 VDC 36 75 VDC 85 264 VAC 105 370 VDC Maximum energy consumption 5 W 25 W 25 W Connectivity Ethernet 1 10 100Base T 2 10 100Base T optional 100Base FX Serial Ports 1 RS 232 422 485 3 RS 232 1 RS 232 Console 16 RS 232 422 485 1 RS 232 Console Optional Serial Ports No No Up to 2 Serial port expansion modules with 16 RS 232 422 485 Internal Modem Optional built in 33 6 Kbps V 34 modem replaces 1 RS 232 serial port Standard built in 33 6 Kbps V 34 modem 1 0 1 normally closed alarm contact indicates normal system operation 1 software controlled normally open relay contact Time Synchronization Standard modulated or demodulated IRIG B input Demodulated IRIG B distributed to all connected devices Automatically sets SMP internal clock Optional internal GPS clock receiver with 0 083 second accuracy Expansion Cap
17. h additional connectivity option 4 A data point cannot be made available to more that 16 control centers at a time 5 1 with protocol converter and data concentrator configuration 4 with mini gateway configuration 6 2 with basic configuration 64 with additional connectivity option 7 The maximum number of data points is the total count of I O points retrieved from the connected devices plus the logical data points that can be provided by the SMP itself to indicate its status and the status of the devices SPECIFYING AN SMP GATEWAY 3 2006 07 10 SMP 4 SMP 16 CP SMP 16 SG Environmental Ambient operating 40 C to 65 C 40 C to 65 C temperature Storage temperature 40 C to 85 C Standards Comliance JEC 61850 3 EMI With few exceptions Yes Immunity Type Tests EEE 1613 EMI Immunity With few exceptions Yes Specifications IEEE C37 90 and IEC With few exceptions Yes 60255 Protective Relay Standards TIA 968 A and CS 03 for Yes Yes Telephone Terminal Equipment CE Marking for Low Yes Yes Voltage Electrical Equipment Warranty 5 years limited gt If you have selected an SMP 4 continue on page 5 for the hardware options gt If you have selected an SMP 16 skip to Specifying SMP 16 CP and SMP 16 SG Options page 7 8 Complete compliance information available on request 4 SPECIFYING AN SMP GATEWAY 2006 07 10 Specifying SMP 4 Options Specify
18. odels to a PC Required for initial system configuration and loading of SMP firmware gt Fora single SMP skip to Specifying SMP Software Options page 11 gt For a redundant configuration continue to Specifying Redundant SMP page 10 SPECIFYING AN SMP GATEWAY 9 2006 07 10 Specifying Redundant SMP Common Considerations The following guidelines apply when specifying a redundant configuration of SMP 16 The SMP 4 model cannot be used in a redundant configuration Both the active SMP and standby SMP must be of the same model with the same hardware options and the same number of additional ports f the GPS clock is installed both SMP Gateways should have their own antenna Two communications links are required between the active and passive SMP Serial or Ethernet links can be used Since only one SMP is active at a time you need only purchase software options and protocol licenses for one SMP You must specify the redundancy software option P SSMP 0401 Redundancy support Provides the capability to group two SMP in a redundant configuration The standby SMP automatically takes over if the main SMP fails Not available for SMP 4 model Connecting Devices to Redundant SMP 16 CP and SMP 16 SG Use the following splitter cable to connect devices to the serial ports of both SMPs P CABC 0112 Single DB 9F to dual DB 9M cable Used to connect a device to two redundant SMP 16 1 cable required for each device