1000 Series Gigabit Media Converter & Industrial
Contents
1. IN TRON THE INDUSTRIAL NETWORK COMPANY 1000 Series Gigabit Media Converter amp Industrial Gigabit Ethernet Switch User Manual amp Installation Guide Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net IN TRON THE INDUSTRIAL NETWORK COMPANY Industrial Gigabit Ethernet Switch Installation Guide 1002MC SX 1000BaseSX multimode fiber media converter 1002MC LX YY 1000BaseLX singlemode fiber media converter 1003GX2 SX 1000BaseSX multimode fiber switch 1003GX2 LX YY 1000BaseLX singlemode fiber switch 1003GX2 B Custom mix and match 1003GX2 switch 1005TX 5 port gigabit Ethernet switch Where YY is 10 for 10km max fiber segment length 40 for 40km max fiber segment length 80 for 80km max fiber segment length 1003GX2 B SFP Mini GBIC Fiber Transceivers NTSFP SX LC Style Connector up to 550m NTSFP LX 10 LC Style Connector up to 10km NTSFP LX 40 LC Style Connector up to 40km NTSFP LX 80 LC Style Connector up to 80km Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net Copyright N Tron Corporation 2008 3101 International Drive Building 6 Mobile AL USA 36606 All rights reserved Reproduction adaptation or translation without prior written permission from N Tron Corporation 1s prohibited except as allowed under copyright laws Ethernet is a registered trademark of Xerox Corporation All other produc
2. THE POSSIBILITY OF SUCH DAMAGES AND LIMITS ITS LIABILITY TO REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON S OPTION THIS DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED IF ANY REMEDY PROVIDED HEREIN SHALL FAIL OF ITS ESSENTIAL PURPOSE DISCLAIMER Some countries states or provinces do not allow the exclusion or limitation of implied warranties or the limitation of incidental or consequential damages for certain products supplied to consumers or the limitation of liability for personal injury so the above limitations and exclusions may be limited in their application to you When the implied warranties are not allowed to be excluded in their entirety they will be limited to the duration of the applicable written warranty This warranty gives you specific legal rights which may vary depending on local law GOVERNING LAW This Limited Warranty shall be governed by the laws of the State of Delaware U S A Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net
3. ED EITHER IN FACT OR BY OPERATION OF LAW STATUTORY OR OTHERWISE INCLUDING WARRANTIES TERMS OR CONDITIONS OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE SATISFACTORY QUALITY CORRESPONDENCE WITH DESCRIPTION AND NON INFRINGEMENT ALL OF WHICH ARE EXPRESSLY DISCLAIMED N TRON NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE OR USE OF ITS PRODUCTS N TRON SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT OR MALFUNCTION IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER S OR ANY THIRD PERSON S MISUSE NEGLECT IMPROPER INSTALLATION OR TESTING UNAUTHORIZED ATTEMPTS TO OPEN REPAIR OR MODIFY THE PRODUCT OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE OR BY ACCIDENT FIRE LIGHTNING POWER CUTS OR OUTAGES OTHER HAZARDS OR ACTS OF GOD LIMITATION OF LIABILITY TO THE FULL EXTENT ALLOWED BY LAW N TRON ALSO EXCLUDES FOR ITSELF AND ITS SUPPLIERS ANY LIABILITY WHETHER BASED IN CONTRACT OR TORT INCLUDING NEGLIGENCE FOR INCIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUNITIVE DAMAGES OF ANY KIND OR FOR LOSS OF REVENUE OR PROFITS LOSS OF BUSINESS LOSS OF INFORMATION OR DATA OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE USE PERFORMANCE FAILURE OR INTERRUPTION OF ITS PRODUCTS EVEN IF N TRON OR ITS AUTHORIZED RESELLER HAS BEEN ADVISED OF
4. Fiber Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 4 10 16 cm Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net Gigabit Fiber Transceiver SFP Characteristics i 550m with 50 125 um am on RX Sensitivity Max SS 20dBm 22dBm 24dBm Wavelength 1310nm 13100 15500 Assumed Fiber Loss 3 5 to 3 75 dB km 0 45 dB km 0 35 dB km 0 25 dB km SX Fiber Optic Cable LX Fiber Optic Cable Regulatory Approvals Safety For use in Class I Division 2 Groups A B C and D Hazardous Locations UL 508 Industrial Control Equipment ANSI ISA 12 12 01 2007 for use in Class I and II Division 2 and Class III Divisions 1 and 2 Hazardous Classified Locations Groups A B C D T4A cUL C22 2 No 14 M05 cUL C22 2 No 213 M1987 for use in Class I Division 2 Hazardous Locations EMI EN61000 6 4 EN55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances Warranty 3 years from the date of purchase FE CE Qr Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net 1005TX KEY SPECIFICATIONS Physical Height Width Depth Weight DIN Rail Electrical Input Voltage Input Current Inrush Current Input Ripple Input Wire Size Environmental Opera
5. O KNOWN GOOD GROUNDING POINT Note Before applying power to the grounded switch you must use a volt meter to verify there is no voltage difference between the power supply s negative output terminal and the switch chassis grounding point If the use of shielded cables is required it is generally recommended to only connect the shield at one end to prevent ground loops and interfere with low level signals i e thermocouples RTD etc Cat5e cables manufactured to EIA 568A or 568B specifications are required for use with N Tron Switches SHIELDED PATCH CABLE STP METALLIC NONMETALLIC T 4 LES Es S l i a r r el mam e P a os Note Strain relief boots not shown for clarity purposes In the event all CatSe patch cable distances are small i e All Ethernet devices are located the same local cabinet and or referenced to the same earth ground it is permissible to use fully shielded cables terminated to chassis ground at both ends in systems void of low level analog signals Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CONNECTING THE UNIT For 10Base T ports plug a Category 3 or greater twisted pair cable into the RJ45 connector For 100 1000Base T ports plug a Category Se or greater twisted pair cable into the RJ45 connector Connect the other end to the far end station Verify that the LNK LEDs are ON once the connection has been completed T
6. cal SFP installed Weight DIN Rail Electrical Input Voltage Input Current Inrush Current Input Ripple Input Wire Size Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude Network Media 10BaseT 100BaseT 1000BaseT 1000BaseSX Multimode 1000BaseLX Singlemode Connectors 10 100 1000BaseTX 1000Base X SFP 4 0 10 16 cm 1 0 2 54 cm 3 61 9 165 cm 0 70 Ibs 0 32 kg 35 mm 10 30 VDC Regulated 200mA max 24VDC Steady State 13 Amp 0 8 ms max 24VDC Less than 100 mV 12 24 AWG 40 C to 85 C 40 C to 85 C 10 to 90 Non Condensing 0 to 10 000 ft gt Cat 3 gt Cat 5 gt Cat Se 50 62 5 125um 7 10 125um One 1 RJ45 TX Copper Port One 1 SFP LC Duplex Gigabit Fiber Port Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 4 10 16 cm Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net Gigabit Fiber Transceiver SFP Characteristics i 550m with 50 125 um am on RX Sensitivity Max SS 20dBm 22dBm 24dBm Wavelength 1310nm 13100 15500 Assumed Fiber Loss 3 5 to 3 75 dB km 0 45 dB km 0 35 dB km 0 25 dB km SX Fiber Optic Cable LX Fiber Optic Cable Regulatory Approvals Safety For use in Class I Division 2 Groups A B C and D Hazardous Locations UL 508 Industrial Control Equipment ANSI ISA 12 12 01 2007 for use in Class I and IJ D
7. e No link activity on cable Link is 10 100Mbs SPD1000 Link is 1000Mbps Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net APPLYING POWER Top View CHASSIS GROUND V Negative GND Return V Positive 10 30VDC Vi Negative GND Return V Positive 10 30VDC DETAIL Unscrew amp Remove the DC Voltage Input Plug from the top header Install the DC Power Cables into the Plug observing polarity on unit Plug the Voltage Input Plug back into the top header Tightening torque for the terminal block power plug is 0 5 Nm 0 368 Pound Foot All LEDs will flash ON Momentarily Verify the Power LED stays ON GREEN Note Either V or V2 can be connected to power for minimal operation For redundant power operation V and V2 plugs must be connected to separate DC Voltage sources Use wire sizes of 12 24 gauge The power cord should be limited to less than 10 meters in order to ensure optimum performance Recommended 24V DC Power Supplies similar to 100 240VAC N Tron NTPS 24 1 3 DC 24V 1 3A Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net N TRON SWITCH GROUNDING TECHNIQUES FOR 1000 SERIES The grounding philosophy of any control system is an integral part of the design N Tron switches are designed to be grounded but the user has been given the flexibility to float the switch when required The best no
8. inutes before touching ALERTE D connectez le cable d alimentation et laisser refroidir 5 minutes avant de la toucher 1000 Series Industrial Gigabit Ethernet Switches The 1000 Series Unmanaged Industrial Gigabit Ethernet Switches support high speed layer 2 switching between ports This series of switches are housed in a ruggedized aluminum enclosure and provide Category 5 compliant 10 100 1000Base T connections for high performance network design and hub repeater upgrades All fiber products utilize the IEEE compliant LC duplex connectors for fiber optic communications in a convenient SFP modular design All 10 100 1000Base T ports utilize the RJ45 shielded connectors The 1002MC MCE is a two port unmanaged media converter that converts 10 100 1000Base T copper to 1000BaseSX LX full duplex fiber The 1003GX2 GXE2 is a three port unmanaged switch that offers one 10 100 1000Base T copper port and two 1000BaseT SX LX full duplex copper fiber ports The 1005TX is a five port unmanaged switch that offers five 10 100 1000Base T copper ports Key Features Compact Space Saving Package Full IEEE 802 3 Compliance Unmanaged Operation Jumbo Frame Support Extended Environmental Specifications 40 C to 85 C Operating and Storage Temperature Supports Full Half Duplex Operation Up to 10 0 Gb s Maximum Throughput MDIX Auto Sensing Cable Auto Sensing Speed and Flow Control Full Wire Speed Communication Store and forward Technology Redundant Po
9. ise immunity and emissions 1 e CE are obtained when the N Tron switch chassis 1s connected to earth ground via a drain wire Some N Tron switches have metal din rail brackets that can ground the switch if the din rail is grounded In some cases N Tron switches with metal brackets can be supplied with optional plastic brackets if isolation is required Users may run a drain wire amp lug from the screw provided on the back face of the enclosure In the event the provided grounding screw has been lost care should be taken to limit the penetration of the outer skin by less than 1 4 Failure to do so may cause irreversible damage to the internal components of the switch Note Ensure the power supply is grounded properly before applying power to the grounded switch This may be verified by using a voltmeter to determine that there is no voltage difference between the power supply s negative output terminal and the chassis grounding point of the switch DRAIN WIRE WITH LUG CONNECTING SWITCH CHASSIS TO KNOWN GOOD GROUNDING POINT METALLIC DIN RAIL CLIP As an alternative grounding method both V legs of the power input connector are connected to chassis internally on the PCB Connecting a drain wire to earth ground from one of the V terminal plugs as DRAIN WIRE WITH shown here will ground the switch and the chassis The power leads LUG CONNECTING from the power source should be limited to 3 meters or less in length SWITCH CHASSIS T
10. ius To install the unit to 35mm industrial DIN rail place the top edge of the included mounting bracket on the back of the unit against the DIN rail at a 15 angle as shown Rotate the bottom of To remove the unit from the 35mm industrial DIN rail pull forward on the unit until it disengages from the bottom of the DIN rail Rotate the bottom of the unit towards you and up the unit to the back away from you until it at an approximate 15 upward angle to snaps into place completely remove the unit 1000 PM Most N Tron products are designed to be mounted on industry standard 35mm DIN rail However DIN rail mounting may not be suitable for all applications Our Universal Rack Mount Kit P N URMK may be used to mount the 1000 Series enclosures to standard 19 racks and our Panel Mount Assembly P N 1000 PM may be used to mount the 1000 Series enclosures to a panel or any other flat surface URMK Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net FRONT PANEL 10 100 1000Base T LNK ACT spp 1000 1000Base SK AX K O OacT From Top to Bottom Green LED lights when Power is connected LNK ACT Link Activity LED SPD1000 1000 Speed LED LEDs The table below describes the operating modes d Power is Applied OFF Power is OFF oN Link established no Activity on cable LNK ACT BLINKING Link established Activity on cabl
11. ivision 2 and Class III Divisions 1 and 2 Hazardous Classified Locations Groups A B C D T4A cUL C22 2 No 14 M05 cUL C22 2 No 213 M1987 for use in Class I Division 2 Hazardous Locations EMI EN61000 6 4 EN55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances Warranty 3 years from the date of purchase FE CE Qr Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net 1003GX2 KEY SPECIFICATIONS Physical Height Width Depth w typical SFP installed Weight DIN Rail Electrical Input Voltage Input Current Inrush Current Input Ripple Input Wire Size Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude Network Media 10BaseT 100BaseT 1000BaseT 1000BaseSX Multimode 1000BaseLX Singlemode Connectors 10 100 1000BaseTX 1000Base X SFP 4 0 10 16 cm 1 0 2 54 cm 3 61 9 165 cm 0 7 Ibs 0 32 kg 35 mm 10 30 VDC Regulated 200mA max 24VDC Steady State 13 Amp 0 8 ms max 24VDC Less than 100 mV 12 24 AWG 40 C to 85 C 40 C to 85 C 10 to 90 Non Condensing 0 to 10 000 ft gt Cat 3 gt Cat 5 gt Cat Se 50 62 5 125um 7 10 125um One 1 RJ45 TX Copper Port Up to two 2 SFP LC Duplex Gigabit
12. n This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of this device in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense INDUSTRY CANADA This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Operation 1s subject to the following two conditions 1 this device digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Cet appareillage num rique de la classe A r pond toutes les exigences de l interf rence canadienne causant des r glements d quipement L op ration est sujette aux deux conditions suivantes 1 ce dispositif peut ne pas causer l interf rence nocive et 2 ce dispositif doit accepter n importe quelle interf rence re ue y compris l interf rence qui peut causer l op ration peu d sir e Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net 1002MC KEY SPECIFICATIONS Physical Height Width Depth w typi
13. ng activity ALERTE Ne pas travailler sur le mat riel ou les c bles pendant les p riodes d activit de la foudre WARNING Observe proper DC Voltage polarity when installing power input cables Reversing voltage polarity can cause permanent damage to the unit and voids the warranty ALERTE Respecter la polarit correcte de tension DC lors de l installation des c bles d alimentation d entr e Inversion de polarit de tension peut causer des dommages permanents l appareil et annule la garantie WARNING Install only in accordance with Local and National Codes of authorities having jurisdiction ALERTE Installer uniquement conform ment aux codes locaux et nationaux des autorit s ayant comp tence WARNING 1005TX only This equipment is open type device and is meant to be installed in an enclosure suitable for the environment that is only accessible with the use of a tool ALERTE 1005TX uniquement Cet quipement est ouvert de type p riph rique et est destin a tre install dans un bo tier adapt a l environnement qui n est accessible qu avec l utilisation d un outil LASER SAFETY 1002MC and 1003GX2 Models CAUTION CLASS 1 LASER PRODUCT Do not stare into the laser ATTENTION PRODUIT LASER CLASSE 1 Ne pas regarder dans le laser Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net ENVIRONMENTAL SAFETY WARNINGS WARNING Disconnect the power and allow to cool 5 m
14. nts may impair suitability for Class I Division 2 ALERTE Risque d explosion Remplacement d un composant peut emp cher la conformit de Classe I Division 2 WARNING Explosion Hazard Do not connect or disconnect any connections while circuit is live unless area is known to be non hazardous ALERTE Risque d explosion Ne pas brancher ou d brancher les connexions lorsque le circuit est sous tension sauf si la zone est connue pour tre non dangereux WARNING Use 110 C or higher rated copper wire 0 22Nm 2 Ib in tightening torque for field installed conductors ALERTE Utilisez 110 C ou nominale sup rieure fil de cuivre 0 22 Nm 2 lb pouce couple de serrage pour le champ install conducteurs WARNING Do not operate the equipment in the presence of flammable gasses or fumes Operating electrical equipment in such an environment constitutes a definite safety hazard ALERTE Ne pas utiliser le mat riel en pr sence de gaz ou de vapeurs inflammables L utilisation de materiel lectrique dans un tel environnement constitue un danger certain WARNING Ifthe equipment is used in the manner not specified by N Tron Corporation the protection provided by the equipment may be impaired ALERTE Si l quipement est utilis d une mani re non sp cifi e par N Tron Corporation la protection fournie par l quipement peut tre compromise WARNING Do not perform any services on the unit unless qualified to do so Do not subs
15. o connect any other port to another Switch or Repeater use a standard Cat e straight through or crossover cable Warning Creating a port to port connection on the same switch 1 e loop is an illegal operation and will create a broadcast storm which will crash the network Alerte Cr ation d un port de connexion du port sur le m me commutateur c a boucle est une op ration ill gale et va cr er une temp te de diffusion qui va planter le r seau TROUBLESHOOTING 1 Make sure the Power LED is ON 2 Make sure you are supplying sufficient current for the version chosen Note The inrush current will exceed the steady state current by 2X 3 Verify that Link LEDs are ON for both ports 4 Verify cabling used between stations Verify that cabling is Category 3 or greater for 10Mbit Operation Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net FCC STATEMENT This product complies with Part 15 of the FCC A Rules Operation is subject to the following conditions 1 This device may not cause harmful Interference 2 This device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installatio
16. on net N TRON Limited Warranty N TRON Corp warrants to the end user that this hardware product will be free from defects in workmanship and materials under normal use and service for the applicable warranty period from the date of purchase from N TRON or its authorized reseller If a product does not operate as warranted during the applicable warranty period N TRON shall at its option and expense repair the defective product or part deliver to customer an equivalent product or part to replace the defective item or refund to customer the purchase price paid for the defective product All products that are replaced will become the property of N TRON Replacement products may be new or reconditioned Any replaced or repaired product or part has a ninety 90 day warranty or the remainder of the initial warranty period whichever is longer N TRON shall not be responsible for any custom software or firmware configuration information or memory data of customer contained in stored on or integrated with any products returned to N TRON pursuant to any warranty OBTAINING WARRANTY SERVICE Customer must contact N TRON within the applicable warranty period to obtain warranty service authorization Dated proof of purchase from N TRON or its authorized reseller may be required Products returned to N TRON must be pre authorized by N TRON with a Return Material Authorization RMA number marked on the outside of the package and sent prepaid and packaged ap
17. propriately for safe shipment Responsibility for loss or damage does not transfer to N TRON until the returned item is received by N TRON The repaired or replaced item will be shipped to the customer at N TRON s expense not later than thirty 30 days after N TRON receives the product N TRON shall not be responsible for any software firmware information or memory date of customer contained in stored on or integrated with any products returned to N TRON for repair whether under warranty or not ADVANCE REPLACEMENT OPTION Upon registration this product qualifies for advance replacement A replacement product will be shipped within three 3 days after verification by N TRON that the product is considered defective The shipment of advance replacement products is subject to local legal requirements and may not be available in all locations When an advance replacement is provided and customer fails to return the original product to N TRON within fifteen 15 days after shipment of the replacement N TRON will charge customer for the replacement product at list price WARRANTIES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON S OPTION TO THE FULL EXTENT ALLOWED BY LAW THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES TERMS OR CONDITIONS EXPRESS OR IMPLI
18. t names company names logos or other designations mentioned herein are trademarks of their respective owners The information contained in this document is subject to change without notice N Tron Corporation makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantability or fitness for a particular purpose In no event shall N Tron Corporation be liable for any incidental special indirect or consequential damages whatsoever included but not limited to lost profits arising out of errors or omissions in this manual or the information contained herein Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net ELECTRICAL SAFETY WARNINGS ALERTE This equipment is suitable for use in Class I Division 2 Groups A B C and D or non hazardous locations only Cet quipement est adapt pour une utilisation dans la classe I Division 2 Groupes A B C et D ou non dangereux endroits seulement This equipment must be used with a Listed UL Industrial Power Supply Cet quipement doit tre utilis avec une alimentation UL Listed industrielle A Recognized or Listed fuse rated maximum 3A minimum 30VDC must be installed on the line side of the device Un fusible reconnu ou class class 3A maximale 30VDC minimum doit tre install sur le c t de la ligne de l appareil WARNING Explosion Hazard Substitution of compone
19. ting Temperature Storage Temperature Operating Humidity Operating Altitude Network Media 10BaseT 100BaseT 1000BaseT Connectors 10 100 1000BaseT X 4 0 10 16 cm 1 0 2 54 cm 3 61 9 165 cm 0 70 Ibs 0 32 kg 35 mm 10 30 VDC Regulated 230mA max 24VDC Steady State 13 Amp 0 61 ms max 24VDC Less than 100 mV 12 24 AWG 40 C to 85 C 40 C to 85 C 10 to 90 Non Condensing 0 to 10 000 ft gt Cat 3 gt Cat 5 gt Cat 5e Five 5 RJ45 TX Copper Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 2 5 08 cm Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net Regulatory Approvals Safety For use in Class I Division 2 Groups A B C and D Hazardous Locations UL 508 Industrial Control Equipment ANSI ISA 12 12 01 2013 for use in Class I and IJ Division 2 and Class III Divisions 1 and 2 Hazardous Classified Locations Groups A B C D T4 cUL C22 2 No 14 M05 cUL C22 2 No 213 M1987 for use in Class I Division 2 Hazardous Locations EMI EN61000 6 4 EN55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances Warranty 3 years from the date of purchase Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red li
20. titute unauthorized parts or make unauthorized modifications to the unit ALERTE Ne pas effectuer de services sur l appareil s il n est pas qualifi pour le faire Ne pas substituer pi ces non autoris es ou de modifications non autoris es de l appareil Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net WARNING Do not operate the unit with the end plates removed as this could create a shock or fire hazard ALERTE Ne pas faire fonctionner l unit avec les plaques d extr mit retir ce qui pourrait cr er une d charge lectrique ou un incendie WARNING Properly ground the unit before connecting anything else to the unit Units not properly grounded may result in a safety risk and could be hazardous and may void the warranty See the grounding technique section of this user manual for proper ways to ground the unit ALERTE Correctement a la terre de l unit avant tout raccordement l unit Unit s pas correctement mise la terre peut entra ner un risque de s curit et pourraient tre dangereux et peut annuler la garantie Voir la section technique de mise la terre de ce mode d emploi des moyens appropri s la masse de l appareil WARNING Do not operate the equipment in a manner not specified by this manual ALERTE Ne pas faire fonctionner l quipement d une mani re non sp cifi e par ce manuel WARNING Do not work on equipment or cables during periods of lightni
21. wer Inputs 10 30 VDC LED Link Activity Status Indication Hardened Metal Enclosure Industry Standard 35mm DIN Rail Mounted Enclosure Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net PACKAGE CONTENTS Please make sure the package contains the following items l 1000 Series Media Converter or Ethernet Switch 2 Product CD Contact your carrier if any items are damaged UNPACKING Remove all the equipment from the packaging and store the packaging in a safe place File any damage claims with the carrier CLEANING Clean only with a damp cloth INSTALLATION Read the following warning before beginning the installation Lire l avertissement suivant avant de commencer l installation WARNING ALERTE Never install or work on electrical equipment or cabling during periods of lightning activity Never connect or disconnect power when hazardous gasses are present Ne jamais installer ou de travailler sur un quipement lectrique ou de c blage pendant les p riodes d activit de la foudre Ne jamais brancher ou d brancher l alimentation en gaz dangereux sont pr sents Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net DIN Rail Mounting Install the unit in a standard DIN rail Recess the unit to allow at least 2 of horizontal clearance for CATSe cable bend radius or 5 of horizontal clearance for Fiber Optic cable bend rad