1.    User Manual    600 watt Power Inverter          Go Power           2014 Go Power  By Carmanah Technologies  Document  MAN_GP 600_vB    Table of Contents      INTRODUCTION      SPECIFICATIONS      FEATURES      INSTALLATION      OPERATION      OPERATING LIMITS      TROUBLESHOOTING      MAINTENANCE      WARRANTY    gpelectric com    10    10    gpelectric com    Low battery alarm on all the  time  LED indicator is red     Low input voltage  Have qualified service techni  1    cian check and replace  Introduction    The Go Power  Inverter series provides mobile power for people on the go  Run  standard AC appliances wherever you travel  Silent  lightweight and simple to  use  Go Power  Inverters can be used in a wide range of applications including  remote homes  RVs  boats and long haul trucks  It will operate most televisions and  VCR   s  personal computers and small appliances including drills  sanders  grind   ers  mixers  blenders and microwaves  The inverter must have a greater power  rating than the load to which it is providing power     Make sure that inverter is  connected to 12 V battery   Check regulation of charging  system     Poor DC wiring  poor  battery condition     Recharge battery  Use proper  cable and make solid connec     tions  Use new battery  To get the most out of your power inverter  it must be installed and used properly     Please read the instructions in this manual before installing and using    8     Maintenance  Very little maintenance is re
2.  position but with no load  the power idle  current is approximately 1 A  see product specifications for exact current draw         a  Ventilation port    Operating limits    Overtemp    The fault LED will come on when the inverter has shut itself down because the inverter  has become overheated  The power inverter may overheat because it has been  operated at power levels above it   s rating  or because it has been installed in a location   which does not allow it to dissipate heat properly  The power inverter will restart  automatically once it has cooled off     a  Ventilation port   Do not obstruct  allow at least 1 inch for air flow     b  Battery terminals  Connect to 12 V battery or other 12 V power  source  Note that         is positive          is negative  Reverse polarity connection will    blow internal fuse and may damage inverter permanently     Overload  The fault LED will come on when the power inverter has shut itself down because Note  Minimum inverter DC cable  amp  DC inverter fuse sizes  see section 4 3 and 4 4   its output circuit has been short circuited or drastically overloaded  Switch the ON   OFF switch to OFF  correct the fault condition  and then switch the ON OFF switch  back to ON   4  Installation    Some induction motors used in refrigerators  freezers  pumps and other motor oper     ated equipment require very high surge currents to start  The power inverter may not 4 1 Where to install   be able to start some of these motors  even though the
3. eet of the batteries  5    gpelectric com gpelectric com    4 2 Hook up and testing    To hook up the inverter please follow these guidelines     Caution   Do not connect this inverter and another AC source  generator or utility power  to the  AC wiring or AC loads at the same time  Doing so will destroy the inverter and void  the warranty  regardless whether the inverter is switched on or off  If you are using  more than one AC source for the AC wiring or AC loads  it is highly recommended that  you install an automatic transfer switch  GP TS   available from Go Power Electric  Inc     1  Unpack and inspect your Go Power  Inverter  check to see that the power switch  is in the OFF position    2  Attach the DC inverter cables to the DC power input terminals on the rear panel of  the power inverter  The     terminal is positive and     terminal is negative  Con  nect the cables to the terminals by placing the lug connector at the base of the  terminal and tightening the terminal screw or nut  Clamp the wires securely and  ensure connections are tight     Caution  A reverse polarity connection may permanently damage the  inverter  Damage caused by reverse polarity connection is not covered  by our warranty     3  First connect the cable from the negative terminal of the inverter to the negative  terminal of the battery  Make a secure connection     Caution  Loose connections result in excessive voltage drop and may  cause overheated wires and melted insulation  Ensure connectio
4. ir rated current draw is within The power inverter should be installed in a location that meets the following require    the power inverter  ments    If the motor refuses to start  observe the battery voltage indicator while trying to a  Dry   Do not allow water to drip or splash on the inverter    start the motor  If the battery voltage indicator drops below 11 volts while the   inverter is attempting to start the motor  this may be why the motor will not start  b  Cool   Ambient air temperature should be between 0  C and 40  C  the cooler the   Make sure that the battery connections are good and that the battery is fully better     charged  If the connections are good and the battery is charged  but the voltage still   drops below 11 volts  you may need to use a larger battery  c  Ventilated   Allow at least two inches of clearance around the inverter for airflow   Ensure the ventilation openings on the rear and bottom of the unit are not ob   Input voltage structed     The power inverter will operate from input voltage ranging 10 V     15 V  If the voltage  drops below 10 7 V  an audible low battery warning will sound and the fault LED will be  on  The power inverter will shut down if the input voltage drops below 10 V  This  protects your battery from being over discharged     d  Safe   Do not install the inverter in the same compartment as batteries or in any  compartment capable of igniting flammable liquids such as gasoline     e  Inverter should be located within 10 f
5. ist them together with about 2 to 3 twists per foot  This  minimizes radiated interference from the cables     7 2 Troubleshooting guide    Problem and Symptoms  Low AC output voltage  95 105 VAC     No output voltage and LED  indicator is red     No output voltage  LED  indicator is red     No output voltage  no lights     Possible Cause   Using standard voltmeter   Overload    Overload     High input voltage     Internal fuse open     gpelectric com    Solution  Use true RMS averaging  meter     Reduce load     Make sure that inverter is  connected to 12 V battery   Check regulation of charging  system  Reduce load     Make sure that inverter is  connected to 12 V battery   Check regulation of charging  system     5 1    6 2    6 3    Operation 3 1 Rear view  GP 600          l b  Battery terminals  To operate the power inverter  turn it on using the ON OFF switch on the front panel     The power inverter is now ready to deliver AC power to your loads  If you are operat   ing several loads from the power inverter  turn them on separately after the inverter  has been turned ON  This will ensure that the power inverter does not have to deliver  the starting currents for all the loads at once     Controls and indicators    The ON OFF switch turns the control circuit in the power inverter ON and OFF  It  does not disconnect power from the power inverter     When the switch is in the OFF position  the power inverter draws no current from  the battery  When the switch is in the ON
6. ng installation     c  Power   Lights green when GP 600 is on     d  Fault   Lights red when when fault has occured     gpelectric com    The power inverter will also shut down if the input voltage exceeds 15 V  This  protects the inverter against excessive input voltage  Although the power inverter  incorporates protection against over voltage  it may still be damaged if the input voltage    is allowed to exceed 20 V     7  Troubleshooting    7 1 Common problems  a  Buzz in audio systems    Some inexpensive stereo systems will emit a buzzing noise from their loud speakers  when operated from the power inverter  This is because the power supply in the  device does not adequately filter the modified sine wave produced by the power  inverter  The only solution is to use a sound system that incorporates a higher quality    power supply     b  Television interference    Operation of the power inverter can interfere with television reception on some  channels  If this situation occurs  the following steps may help to alleviate the    problem     e Do not operate high power loads with the power inverter while watching    television      lt  Make sure that the antenna feeding your television provides an adequate      snow free     signal and that you are using good quality cable between the  antenna and the television     e Move the television as far away from the power inverter as possible     e Keep the cables between the battery and the power inverter as short as  possible and tw
7. ns are  tight     4  Before proceeding further  carefully check that the cable you have just con  nected is going from the negative terminal of inverter to the negative terminal of  the power source  battery      5  Install the inverter fuse into the positive lead  Fuse should be located within 12     of battery  Ensure all connections are tight and secure   See 4 3     6  Connect the cable from the positive terminal of inverter to the positive terminal of  the battery  Make a secure connection  Check your polarity     Caution  Connecting this inverter to AC distribution wiring or AC loads in  which the neutral and ground are connected  bonded  will damage the unit  and void the warranty     7  Set the power switch to the ON position  Check that the power LED is ON  and if  not  check your battery bank and the connections to the inverter     Warning  You may observe a spark when you make this connection  since current may flow to charge capacitors in the power inverter  Do  not make this connection in the presence of flammable fumes  as   6 explosion or fire may result     gpelectric com    8  Set the power inverter switch to the OFF position  The power LED light may blink  and go dim  The internal alarm may sound momentarily  This is normal  Plug the test  load into the AC receptacle on the front panel of the inverter     9  Set the power inverter switch to the ON position and turn the test load on  the  inverter should supply power to the load  If you plan to measure the ou
8. quired to keep your inverter operating properly  You should    your inverter     clean the exterior of the unit periodically with a dry cloth to prevent accumulation of 9 ifi i  dust and dirt  At the same time  tighten the screws on the DC input terminals  j Spec cations  2 1 GP 600 Inverter 12V  Output 600 W  Output wave form Modified Sine Wave  9  Warranty Output voltage 115 VAC rms  Regulation  5  10   This product is covered by Carmanah Technologies  Go Power   12 month standard DC input voltage 10 15 V  warranty  Low battery alarm  2  10 5 V  Visit gpelectric com for additional information  Low battery shut down   2  10 V h  Before contacting Go Power    s customer service department  please visit gpelectric  TINGI ENG  80 90   l l l Frequency  1  60 Hz  com to read the    frequently asked questions    section of our website to troubleshoot the No load current 0 2 A  problem  If trouble persists  Surge rating 860 W  1  Call your Go Power     Technical Support team  1 866 247 6527  Over thermal protection Yes l  2  Return defective product to place of purchase  Cooling fan Yes   continuous  Overload protection Yes  Dimensions  LxWxH  230 x 85 x 51 mm  9    x 3 4    x 2     Net weight 2 1 kg  4 6 lbs  Inverter Install Kit Included  10  gpelectric com gpelectric com    3  Features  3 1 Front view     GP 600    c  Power d  Fault       a  AC outlet b  ON  OFF switch    a  AC outlet   Outlet sockets available  North America    b  ON  OFF switch   Leave in the OFF position duri
9. tput  voltage of the inverter  a true rms meter must be used for accurate readings     4 3 Cables    Cables are included with the unit  The battery interconnect cables supplied with the GP   600 inverter are not fused  If these cables are used  it is recommended a 70 amp fuse is  placed in line with the positive wire  If user supplied cables are preferred  please use 8  ft or less of  6 Cable with a 70 Amp fuse  Install the inverter fuse into the positive lead   Fuse should be located within 12    of battery  Ensure all connections are tight and secure     4 4 Inverter Fuse Example  e GP 600   110 amp fuse with 10     4 wire    12 V Batteries            Ou   6 V Batteries    Go Powe DUL FF a          GP Inverter       Installation using two 6 volt batteries  7    gpelectric com    
    