Home

RC414 Universal Optical Converter/Repeater User Manual

image

Contents

1. 7 4 1 DIMENSIONS vis AWA AAA AAA SAA AA AA AA Ye eite 7 4 2 lee H 5 Functionality 9 5 1 Typical application i e eben i te tes a 9 6 Installation amp Preparation essent 10 6 1 Installations ertt Reate e bes 10 6 2 DIP switches conferat onus 10 7 Network manage me iesse edel 14 7 1 SHOW rei UE 14 7 2 ee Deet UE 14 7 3 Module reset and loop back 15 B COSA a E 16 RA SECOM Beijing Raisecom Science amp Technology Co Ltd 2 Overview 2 1 Introduction A single RC414 converter is used to connect two devices which are between a long distance or operating with dissimilar optic fiber mode e g single mode and multi mode And RC414 provides 2R reshape and reamplify function for services within the rate range of 42Mbps 2 5GMbps and provides 3R function for standard rate services GB STM 4 STM 1 and FE 2 2 Product features Multi rate flexibly access fiber optic signals at rates of 1 25G or lower Optical modules for different rates different distances and different wavelengths are available for different customer needs and you also can select relative optical connectors to achieve single multi mode conversion Transparently transmitting variable rate services when you use high rate optical connector low rate services also can be transmitted standard rate services of Gb STM 4 ST
2. Off Normal Normal Normal SW1 4 Fault Return Client FR C Fault return of client side Client side TX of will shutdown if there is no RX signal When pair uses RC414 this function is no allowed to enable at the same time by both ends Off Normal Normal Normal Network management configuration has higher privilege This DIP switches configuration is valid when there is no network management And when there is network management network management configuration will be valid SW2 function table CDR configuration DIP switches Switch Status Function Description Privilege SW2 1 Reserved Reserved SW2 2 On Line Loop Line side loop back forced Off Normal Normal configured through management and status is normal Then module can be network the default back higher than network Management and Force to set loop has privilege SW2 3 On Client Loop Client side loop back forced Off Normal Normal configured through management and status is normal Then module can be network the default back higher than network Management and Force to set loop has privilege 11 RA SECOM Beijing Raisecom Science amp Technology Co Ltd SW2 4 On Disable Disable CDR in this condition the Network module has 2R function
3. SC 1310 lt 20 20 0 5 10 3 SS15 SC 1550 E lt 20 20 0 5 Jitter index RC414 jitter value complies with ITU T standard 1 jitter value STM level ITU T Typical value of requirement 414 STM 1 500Hz 1 3MHz 0 30UI 0 050 optical 65KHz 1 3MHz 0 10UI 0 030 HRA SECOM Beijing Raisecom Science amp Technology Co Ltd STM 4 1000Hz 5MHz 0 30UI 0 004 optical 250KHz 5MHz lt 0 100 0 004 1 NOTE this is the average value of many times measure ACTERNA ANT 20 2 jitter transfer and jitter tolerance LZ Je Laren rau f gem Ene E STUER TRANSFER FUNCTION Variable Amplitude TOL JITTER Mark E 782 OO Type A Tolerans Mack DS 7000 FEM Di mr prm nime nn pe n 1001 Di 1000 Typical figure of RC414 jitter transfer Typical figure of RC414 jitter tolerance HRA SECOM Beijing Raisecom Science amp Technology Co Ltd 4 View and indicators 4 1 Dimensions Dimension H W D W L H 91mm 25mm 170mm Weight package is not included 4 2 Front view RC414 Gb S1 S3 x CLIENT LNK K OO LNK Panel mesh print and interfaces as above figure the optical connector type is 1 9 LED indications LED Color Indication PWR Green po
4. management Off CDR Enable Enable CDR configuration has higher privilege SW2 5 On Manual Set rate manually according to Network SW2 6 8 management Off Auto Controlled by CPU When LOS configuration has indicator is off RC414 will set CDR higher privilege rate automatically from STM 16 to FE to accommodate the access data rate until there is no LOL this indicates the module has locked that rate SW2 6 2 6 2 7 2 8 Data rate These three bits are valid when SW2 7 Off Off Off C48 SW2 5 is on SW2 8 Off Off On Gb Off On Off C12 Off On On C3 On Off Off FE Other status Reserved Line side information switches SW3 Switch Status N on F off Description SW3 1 3 2 Rate FF 155M FN 622M NF 1 25G NN 2 5G reserved SW3 3 3 5 Reserved Reserved SW3 6 3 8 Distance NNN M NNF 51 S2 NFF S3 FNN SS13 FNF 5515 FEN SS23 FFF SS35 Client side information switches SW4 Switch Status N on F off Description SW4 1 4 2 Rate FF 155M FN 622M 12 RA SECOM Beijing Raisecom Science amp Technology Co Ltd NF 1 25G NN 2 5G reserved SW4 3 4 5 Reserved Reserved SW4 6 4 8 Distance NNN M NNF S1 NFN S2 NFF S3 FNN 5513 5515 EEN SS23 FFF SS25 Default settings of SW1 and SW2 are OFF fault pass through an
5. 3 5W Humidity 5926 9096 non condensing 3 2 Optical interface specifications Optical interface index is in the following table and these are EOL End Of Value value Over Optical RX CIN Typical Wave load sensitivity P Optical Rate transmission Mbos Type Connector length power point dBm TIME loss P nm dBm BER E 1 m dB Km 0 FE 18 14 M D 131 29 og 2 3 STM 1 26 SHE wa S 15 8 Si DSC 1310 5 34 25 0 5 S2 DSC 1310 500 8 34 10 60 0 5 10 D 1 36 15 120 0 25 S3 SC 550 O DFB BA SECOMH Beijing Raisecom Science amp Technology Co Ltd 120 8 SS13 SC 1310 7 lt 30 25 0 5 120 8 SS15 SC 1550 7 lt 30 25 0 5 ss23 sc 1310 500 8 lt 22 100 50 0 5 SS25 SC 1550 5 0 8 lt 32 100 50 0 5 10 3 M DSC 850 3 47 0 55 3 10 3 S1 DSC 1310 _ lt 25 25 0 5 3 S2 DSC 1550 2 DF lt 22 10060 0 25 B STM 4 9 S3 DSC 1550 2 DF 250 100 0 25 SS 32 APD B 10 SS13 SC 1310 s S lt 22 20 0 5 10 5515 sc 1550 lt 22 20 0 5 10 3 M DSC 850 5 lt 15 00 0 55 3 1 51 DSC 1310 s S lt 23 25 0 5 ap 3 S2 DSC 1550 2 DF lt 20 10060 0 25 B Gb ap 59 S3 DSC 1550 2 DF 250 100 0 25 12 30 APD B 10 3 SS13
6. 4 can provide longer transmission distance through multilevel cascades The cascade devices number of RC414 is not limited in theory And we do the test uses 16 RC414 converters to cascade and we promise cascade 16 or fewer RC414 RA SECOM Beijing Raisecom Science amp Technology Co Ltd 6 Installation amp Preparation 6 1 Installation Slide RC414 into two adjacent installation slots and connect the fiber cable If client side device and line side fiber are connected normally RC414 indicators LNK and LCK will be steady ON status When install the device please be attention 1 The connection sequence of fiber cables is not specified but to satisfy the requirement of rate auto sensing of single module default setting enables rate auto sensing we recommend connect RX of client side fiber first rate auto sensing functioning normally when RX fiber of client side connects correctly 2 Avoid Rx power of optical port is too high Please do not connect optical port output with optical port input without attenuator this may result in abnormal work of optical port or even damage it Optical module of different rate and different transmission distance has different optical saturation power usually optical power less than 8dBm will satisfy all the optical connectors 3 Please set the rate of Ethernet services manually In some peculiar case FE service may be regarded as GE service when use GE connectors and in this condition there may be packe
7. M 1 FE and other non standard rate services are all included Flexible debug function provides fault pass through and fault return function on line side and client side for different customer needs Retime function a single RC414 converter has 3R function Reshape Reamplify and Retime the low output jitter and client output jitter attenuating function can extending transmission distance Loop back function a single RC414 converter can provide bi direction loop back function for system debug and device installation 2 3 Ordering information RC414 XX YY ZZ Optical Rate Optical Optical converter interface interface repeater transmission transmission RC414 distance of distance of line side client side BA SECONMH Beijing Raisecom Science amp Technology Co Ltd C3 155M C12 622M Gb 1 25G M 51 52 M 51 52 53 5513 5515 SS23 SS25 S3 5513 5515 SS23 SS25 note optical connector type of SS23 and SS25 is only available at rate of C3 For example RC414 Gb M S1 is 1000M single mode to multi mode optical converter 414 3 52 52 is converter repeater 155M single mode 3 Parameters 3 1 Device specification to single mode optical Dimension H W D 91mmx25mmx170mm Optical connector SC PC Work temperature 0 0 450 Storage temperature 40 80 Power consumption WI Typical value
8. RAISECOM RC414 Universal Optical Converter Repeater User Manual Beijing Raisecom Science amp Technology Co Ltd 10 2005 BA SECOMH AN Beijing Raisecom Science amp Technology Co Ltd 1 Cautions Please read the following notices carefully before installing and using the device Raisecom does not respond to any loss that caused by violating safety notice RC414 provides optical port and there is visible and invisible laser radiation when open Do not stare into the beam or view directly with optical instruments and if the optical port is not used please insert the plug RC414 is integrated device that has precise elements please avoid violent shakes and impacts and do not disassemble or maintain the device yourself If it is required please do it under the guide of our technical staff following in the steps of anti static Please contact us if there is any need There must be grounding protection for the sake of safety do not disassemble the device yourself we regard it as you waiver your rights of repair guarantee RA SECOM Beijing Raisecom Science amp Technology Co Ltd Catalog T AUNA E A E 1 e A 3 2 1 Wer 3 2 2 Product feat res pee eee er REED PERDERE EELER 3 2 3 Ordering information 3 E H 3 1 Device specificatiOf E 4 3 2 Optical interface specifications 4
9. d fault return disable loop back disable CDR enable and rate auto sensing enable SW3 and SWA stand for optical connector information and cannot be set by users 13 BA SECOMH RC414 can be controlled configured and Beijing Raisecom Science amp Technology Co Ltd 7 Network management management system EMS version is1 15 build 2 or higher 7 1 Show module Use Show module to inquire RC414 status information inquired through Raisecom network Number Status name items can be Value Control and controlled and configured configure features C3 C12 GB Can be inquired 1 Module type 51 52 53 5515 but not 5513 5525 and etc configurable Fault pass th hf li C be inqui 2 ult p roug rom line Enable amp Disable an e inquired side to client side and configurable Fault pass through fr lient C be inqui 3 i ugh from clien Enable amp Disable an i inquired side to line side and configurable 4 Fault return of line side Enable amp Disable 0 ER de and configurable Can be inquired 5 Fault return of client side Enable amp Disable and configurable Optical t of li ide LNK inqui 6 ptical port of line side Up amp Down Can inquired status and configurable 7 Optical port of client side LNK Up amp Down Can i inquired status and configurable 8 Optical port of line side LCK Loss Of LOCK amp be inquired status LOCK and configurabl
10. e 9 Optical port of client side LCK Loss Of LOCK amp be inquired status LOCK and configurable C qnoi 10 CDR work status Enable amp Disable ech e marea and configurable E RE 11 GE GB STM4 STM1 Can pe inquired FE and N A and configurable 7 2 Configure module The configurable items can be configured through Config module in above table and these items include fault debug configuration and CDR configuration Fault debug includes fault pass through from line side to client side fault pass through from client side to line side line side fault return client side fault return and etc CDR configuration includes enable or disable CDR and set the CDR rate as auto sensing or forced rate 14 RA SECOM Beijing Raisecom Science amp Technology Co Ltd 7 3 Module reset and loop back detection Host site module can be reset through Reset module command After reboot the working mode and status will remain the same as that before reboot Use loop config to set loop back of line side or client side for debug and installation 15 RA SECOM Beijing Raisecom Science amp Technology Co Ltd 8 Q amp A Fault Resolve 1 LNK indicator off Check the input power of relative optical port 2 Client LNK on and LCK off 1 check the input signal of client side 2 check the optical RX power of client side 3 if rate auto sensing enables please change it to manual configuration mode
11. t loss even if service connection is valid 6 2 DIP switches configuration RC414 has 4 banks of DIP switches SW1 is 4 bit switches and SW2 SWA are 8 bit switches SW1 is fault pass through and fault return function configuration switch SW2 is CDR configuration switch SW3 is line side optical port information switch and SW4 is client side optical port information switch The entire DIP switches configuration is the module initialization configuration And network management configuration has higher privilege than that of DIP switches except configuring loop back function 10 BA SECOMH Beijing Raisecom Science amp Technology Co Ltd SW1 function table fault pass through and fault return function Switch Status Mesh print Function Description Privilege SW1 1 On Fault pass Line to Client FP_LC Fault pass through from line side to client side Optical TX of client side will shutdown if there is no RX signal of line side Off Normal Normal Normal SW1 2 Fault pass FP_CL Client to Line Faults pass through from client side to line side Optical TX of line side will shutdown if there is no RX signal of client side Off Normal Normal Normal SW1 3 Fault Return Line FR_L Fault return of line side Line side TX of will shutdown if there is no RX signal When pair uses RC414 this function is not allowed to enable at the same time by both ends
12. through switches SW2 5 and set the rate through SW2 6 8 4 if above steps still cannot resolve the problem use SW2 4 to disable CDR 5 contact technical staff of RAISECOM 3 Client LNK and LCK on 1 check whether client side data and line side Line LNK on and LCK off data is at same rate 2 check optical power of optical port 3 if rate auto sensing enables please change it to manual configuration mode through switches SW2 5 and set the rate through SW2 6 8 4 if above steps still cannot resolve the problem use SW2 4 to disable CDR 5 contact technical staff of RAISECOM 4 Rate auto sensing failed but Check optical interface information switches manual configuration normal There is the possibility that optical connector is 1000M but the input data rate is 100M And set the rate manually 5 Disconnect sometimes Check the optical power of all optical ports first there is packet loss and if the power consumption value is normal set the rate manually 6 Network management is not Make sure that EMS version is 1 15 build 4 or available higher and MCU chip U7 is tightly contacted with pad 16 RA SECOM Beijing Raisecom Science amp Technology Co Ltd BROADBAND to RAISECOM 22005 Beijing Raisecom Science amp Technology Co Ltd All trademarks are the property of their respective owners Technical information may be subject to change without prior notification
13. wer ON indicates power supply functioning normally OFF indicate power supply functioning abnormally or invalid LNK Green link ON indicates there is a valid link OFF indicates there is no input signal LNK of client side ON indicates there is input signal of client side OFF indicates there is no input signal of client side LNK of line side ON indicates there is input signal of line side OFF indicates there is no input signal of line side LCK Green lock ON indicates signal is locked OFF indicates signal is loss of lock LCK of client side ON indicates signal of RX channel CLIENT gt LINE is locked OFF indicates signal of RX channel CLIENT gt LINE is loss of lock LCK of line side ON indicates signal of TX channel RA SECOM Beijing Raisecom Science amp Technology Co Ltd LINE gt CLIENT is locked OFF indicates signal of TX channel LINE gt CLIENT is loss of lock RA SECOM Beijing Raisecom Science amp Technology Co Ltd 5 Functionality amp Application 5 1 Typical application i interconnect optical devices to convert fiber type from single mode to multi mode and extend transmission distance Single mode fiber optical Single mode and multi port mode conversion of RC414 port ii RC414 Provides OEO relay function to extend transmission distance Device Device with with optical optical port port RC414 relay application RC41