1. 2 4 1 Number clip The numbers allow a unique identification and selection of the SDconnect This is necessary for wireless operation and is determined during configuration Each number may be assigned only once in the workshop as otherwise fault free operation cannot be ensured Daimler AG Last updated 03 11 valid until revoked Technical Information Workshop equipment GSP Ol Page 12 of 35 HPC R800 D 70546 Stuttgart SDconnect Manual A Mercedes Benz 2 4 2 Display buttons and icons The display is divided into two Icons are displayed permanently in the upper area see illustration below no 0 8 In the lower area details appear when calling up information when setting parameters for the device and during the diagnosis LED A J Abort Return i vuma diaii d 0 2 Connection Information Settings Sf Confirm Power supply Working status c Ready Working Rechargeable battery forming _ Cable completed Rechargeable battery forming incomplete External power supply A Road WLAN Goo Defective Workshop WLAN co Forming 14 hour charging time when charging the battery for the first time 2 4 3 Q Searching for wireless network LED and acoustic signal Display Working status Acoustic signal illumination Switched off off off Switched on Operational Working flashes slowly lights up flashes slowly once briefly
2. WLAN card faulty to check this open SDconnect remove and reinsert WLAN card swap with another approved WLAN card if necessary If the LEDs on the card do not light up the card is probably faulty and you should purchase a new one from a specialist store If the cause is not a fault in the WLAN card e g as shown when swapped over please connect the two systems by cable If a wired communication does work the error is either in the IT network please contact your network administrator or in the Configuration please contact the Star Diagnosis User Help Desk UHD Check whether the WLAN card in your Star Diagnosis system is active in SDnetControl If it is not possible to establish a connection either via the WLAN or by cable SDconnect is faulty have the Star Diagnosis User Help Desk UHD arrange an exchange Check the operating mode of the Star Diagnosis system and the SDconnect Road wireless network Workshop wireless network cable gt must be identical Correct if necessary Open SDnetControl Open MUX tab select SDconnect and send a test signal If error code 750 is shown check configuration data consult IT administrator if necessary Check configuration in SDconnect Toolkit gt Information Also Check the configuration in SDnetControl in the Configuration tab For both compare the available data with the data from the SDnetAssist questionnaire If not effective contact Star Diagnosis User Help Desk UHD
3. General information The advantages of the product are described in the following section Wireless data transfer A new technology for wireless vehicle diagnosis that s SDconnect This multiplexer sends fault detection data over the WLAN to the Star Diagnosis compact w or Star Diagnosis compact In workshop mode the data is transmitted via an access point over the workshop network Alternatively in road mode SDconnect transmits data directly to the Star Diagnosis system inside or outside the workshop This means that the user can move freely and unhindered when diagnosing A wired connection via cable including a strain relief also continues to be available Advanced diagnosis options SDconnect with its new integrated Star Diagnosis CAN tool offers new possibilities for troubleshooting The tool aids the monitoring and recording of data flows in the vehicle This enables the diagnostic technician to examine vehicle functions with even more accuracy and to determine faults more precisely Bus wake up and bus keepawake events can be detected with SDconnect This function is called up in DAS SDscan the separate expert software offers even more complex CAN diagnostic functions The prerequisite for using this software is the relevant technical know how Your national representative or training center will be pleased to advise you Improved speed The speed of data intensive diagnostic processes for example when flashing and coding c
4. Repeat key Key entry format The IP address for the SDconnect should end the same as its name to make identification easier For example 192 168 2930 Daimler AG Last updated 03 11 valid until revoked Technical Information Workshop equipment GSP Ol Page 22 of 35 HPC R800 D 70546 Stuttgart SDconnect Manual Mercedes Benz Step 5 Set WLAN country setting Select your country in the dropdown menu Click Start to save and apply your settings Step 6 adjustment of the roaming characteristics within your workshop environment applies only for field organization with multiple access points Select Software update in the Toolkit Select the WlanRoamingEnableAtHighQuality package if you have an average signal strength lt 40 RSSI in the workshop Select the WlanRoamingEnableAtLowQuality package if you have a good signal strength gt 40 RSSI in the workshop Administration Mercedes Benz WLAN regional setting WLAN eters DHCP IP address Network screen Gateway SSID network name Encryption Network screen SSID network name Encryption Key EM LAN parameters nuro NowLAN WORLD 192 168 10 124 255 255 255 0 werkstatt WEP ZASI 192 168 10 123 255 255 255 0 WEP ASCII l Delivery condition SDconnect Toolkit Administration Testing the operability of SDconnect in the workshop WLAN network Note the output in the SDconnect di
5. Serial number Working state WLAN mode WLAN regional setting Last used Power supply Hardware Status WLAN parameters workshop WLAN parameters road LAAL o re ester informa Toolkit version Tester name IP Multicast UDP Broadcast Hardware version Software versions 23 57222 Accessible No WLAN WORLD 0 days ago Vehicle OK Last updated 03 11 valid until revoked Page 24 of 35 SDconnect Manual Mercedes Benz 5 4 Performing a guided self diagnosis Step 1 Select SDconnect SDnetControl x Version 1 6 0 3 Connections Select MUX Configuration Network tools Select the SDconnect to be diagnosed through SDnetControl Select the desired SDconnect If no SDconnect is first selected Toolkit uses the SDconnect currently selected in SDnetControl Toe no signal A plugged in Part D will be diagnosed 30 meena zl Step 2 Select menu entry Self Diagnosis Click on CAESAR Self Diagnosis in the Self Diagnosis IMS990 Self Diagnosis DMI Self Diagnosis window in StarUtilities SDconnect Toolkit is started CAESAR Self Diagnosis Windows Self Diagnosis Chip Card Reader Self Diagnosis Network Self Diagnosis Battery Self Diagnosis WLAN signal strength CPU usage DAS Trace Log Test adapter 2035890 76300 eee Self diagnosis Daimler AG Last updated 03 11 valid until revoked Technical Information Workshop equipment GSP Ol Page 25
6. Star Diagnosis Info Star Diagnosis variant Operating system Network Star Diagnosis compact w Windows XP LAN Star Diagnosis compact WLAN A Mercedes Benz Objective This document provides instructions for your Star Diagnosis SDconnect multiplexer Overview of contents 1 GEMET al ITOK ATION ees nasscssicuerecissiteeaveccewstoassaksnascnntssesaen baw donsnnneee pnd R AEE EEE EEOAE OAE 4 2 HardWare sooioincnei oudn EEE E AANE NNE 5 2 1 CNA SGT OTOP UO US esnin a a seen eats 5 2 1 1 Connection options on SDCOnNNect esseeseeeeseesssessreessessseessessseeseesseessessssesseessseessoesseeesseesseesseessesseeesees 5 AN2 Options for connecting to Star Diagnosis compact W ssesssessesssessesssessesssssrsseessessresssessressessesssesseesses 5 2 1 3 Options for connecting to Star Diagnosis compact P E E EEE E A A T 6 2 2 Opening the SDconnect access to the battery compartment WLAN card SD memory Card ceceeseeeee 8 2 2 1 Removing the COVED cvesscscsconstsevesncnenesyerisevsbadencoes nnbencnorsesnanevunedeacesenedinneeesenedvneveneneaksnwvensvenercacsdwetiantenteeneaerien 8 2 2 2 SON O STO ara E E E AE A EO 8 2 3 WLAN card batteries and SD memory Card in SDCONMNECE csscsesccsscessecssccssssssseeseeecsseesseecsnecessseseeeessecsaneeses 9 2 3 1 WEAN E T e E E E ti cuesseneecsesecuaeee 9 Zoe Rechargeable DALLONIES csnnsesnscencasgscensvessdennaasanestanososeaaaqegaesssunessdarane
7. is on the left hand side at the network Internet is found in the middle of the left bottom hand side Daimler AG Last updated 03 11 valid until revoked Technical Information Workshop equipment GSP Ol Page 6 of 35 HPC R800 D 70546 Stuttgart SDconnect Manual A Mercedes Benz 2 1 3 2 Wireless connection to Star Diagnosis compact Road WLAN In this connection mode Star Diagnosis compact and SDconnect communicate with each other directly by wireless This is known as an ad hoc connection and no access point is required A connection can be established from Star Diagnosis to the Internet intranet via a LAN connection in this mode Note This type of connection must be configured The procedure is described in sections 3 and 5 Workshop WLAN In this connection mode Star Diagnosis compact and SDconnect communicate with each other by wireless by way of an access point infrastructure In addition Star Diagnosis compact is able to set up a wireless connection to the Internet intranet through the access point Note This connection mode requires that the Star Diagnosis compact and SDconnect are linked into the workshop s IT infrastructure The procedure is described in sections 3 and 5 Daimler AG Last updated 03 11 valid until revoked Technical Information Workshop equipment GSP Ol Page 7 of 35 HPC R800 D 70546 Stuttgart SDconnect Manual A Mercedes Benz 2 2 Opening the SDconnect access to
8. Check WLAN parameters correct as necessary SDconnect Toolkit gt Register configure Switch off the device then open Check whether the WLAN card is properly inserted If not effective contact Star Diagnosis User Help Desk UHD Check whether the LAN cable is connected Disconnect if necessary Check parameters in SDnetControl adjust if required Configuration tab gt Network adapter in SDnetControl wireless network connection must be enabled see section on network adapters in the SDnetControl manual If not effective contact Star Diagnosis User Help Desk UHD Make sure that no metallic covers are interfering with the connections Workshop wireless network Move closer to the access point Road wireless network Reduce the distance between the SDconnect and your Star Diagnosis system Last updated 03 11 valid until revoked Technical Information Workshop equipment GSP Ol Page 29 of 35 HPC R800 D 70546 Stuttgart SDconnect Manual A Mercedes Benz 6 2 Star Diagnosis User Help Desk UHD The Star Diagnosis Hotline Star Diagnosis User Help Desk UHD as the central contact point for your Star Diagnosis systems is always available to answer your queries The Star Diagnosis User Help Desk UHD will assist you with All IT related questions on your Star Diagnosis system Problems with the Star Diagnosis hardware Star Diagnosis system SDconnect Problems with the operating system Windows XP in
9. Step 2 Set SDconnect name The following user interface appears after you click on Register configure Click on Select Name and a new window will open In the new window select a free name that has not yet been assigned to any other SDconnect by clicking on the corresponding number e g 21 yellow Note Previously assigned names are grayed out The SDconnect selected is highlighted in color against the other numbers here 23 yellow Next click on OK Daimler AG Technical Information Workshop equipment GSP Ol HPC R800 D 70546 Stuttgart SDnetControl LT Version 1 6 0 3 Connections Select MUX Configuration Network tools Info Network Server Profile a Cee SDco Mercedes Benz Administration WLAN regional setig J WLAN pereweters wothchop DHE LJ P sjes 132 168 10 128 Netewt ocean 25 1255 25 0 mebotyi WEP ASDI 122 168 10 13 z5 25 75 0 Select Number Select the name for SDconnect fi BE Last updated 03 11 valid until revoked Page 21 of 35 SDconnect Manual Mercedes Benz Step 3 Enter workshop WLAN parameters SDconnect Toolkit Mercedes Benz Bes d Information Rlegister eoniigure Self diagnosis Software update CI General information E a Select name Serial number 57222 WLAN mode No WLAN WLAN regional setting WORLD EIM WLAN parameters workshop 192 168 10 124 Your SDconnect i
10. compact w is used only for connecting to the compact w is used only for the SDconnect connection workshop network Internet Daimler AG Last updated 03 11 valid until revoked Technical Information Workshop equipment GSP Ol Page 5 of 35 HPC R800 D 70546 Stuttgart SDconnect Manual A Mercedes Benz 2 1 2 2 Wireless connection to Star Diagnosis compact w Road WLAN In this connection mode Star Diagnosis compact w and SDconnect communicate with each other directly by wireless This is known as an ad hoc connection and no access point is required A connection can be established from Star Diagnosis to the Internet intranet via a LAN connection in this mode Note This type of connection must be configured The procedure is described in sections 3 and 5 Workshop WLAN In this connection mode Star Diagnosis compact w and SDconnect communicate with each other by wireless by way of an access point infrastructure In addition Star Diagnosis compact w is able to set up a wireless connection to the Internet intranet through the access point Note This connection mode requires that the Star Diagnosis compact w and SDconnect are linked into the workshop s IT infrastructure The procedure is described in sections 3 and 5 2 1 3 1 Wired connection to Star Diagnosis compact The LAN interface for connecting the The SDconnect connector socket on the Star Diagnosis compact with the workshop Star Diagnosis compact
11. device for the first time 2 3 2 2 Installing and removing rechargeable batteries Once the housing cover has been removed the battery compartment can be opened To do this remove the central Torx screw C and move the bracket down as illustrated in the picture Please make sure that the batteries are in working order and have no external damage or dirty contacts Damaged or defective batteries can lead to damage or malfunctions within the unit When inserting the batteries check the polarity and insert them according to the specifications also see the adjacent illustration Warning Incorrectly inserted batteries may lead to damage or faults in the unit Note the tightening torque for screw C is 50 cNm 0 5 Nm A torque wrench must be used to ensure that the screws are tightened to this torque Note The batteries are commercially available components If you need to replace them please obtain your new batteries from a specialist store The following table lists recommended models Minimum requirements for rechargeable batteries and recommended models 6 rechargeable NiMH batteries Sanyo HR 3U 1700 Size AA also mignon or R6 Sanyo HR 3U 2 100 Capacity from 1700 mAh to 2300 mAh GoldPeak GP170AAHC Recognized by UL GoldPeak GP 180AAHC Can be quickly recharged with 1A GoldPeak GP200AAHC Possible continuous discharge current at least 2A GoldPeak GP2 10AAHC Impedance 1 kHz under 30 mR GoldPeak GP23
12. 00 CET CET CET CET CET CET Local time CET 49 0 1805 2233 33 49 1805 2233 32 49 1805 2233 30 49 1805 2233 29 49 1805 2233 31 49 1805 2233 42 49 0 1805 2233 63 Last updated 03 11 valid until revoked Page 30 of 35 SDconnect Manual A Mercedes Benz 7 Warning instructions and operating instructions This section contains important warnings as well as operation instructions for the SDconnect multiplexer it is essential that you adhere to these 7 1 General Please follow the installation instructions in this manual The unit is intended for commercial use and should only be operated by trained personnel according to the instructions 7 2 Storing the SDconnect Keep the unit in a cool and dry location The unit should be kept at temperatures between 20 C to 65 C Do not keep the unit in areas where there are corrosive gases or liquids 7 3 Operation of the SDconnect When you are working with the SDconnect various safety instructions apply as is the case for other work carried out in the workshop Special safety information is not provided for each component as the provided information is to be applied analogously to components that are not mentioned In addition to this document please also observe the information on using SDconnect in the Manual for Star Diagnosis Users and in your system s general terms and conditions General Safety Information Read al
13. equipment GSP Ol Page 16 of 35 HPC R800 D 70546 Stuttgart SDconnect Manual Mercedes Benz Step 3 Ensure power supply Ensure that you have a power supply for your SDconnect a via the charging adapter test adapter and the Star Diagnosis System s PSU or b via connection to a vehicle Step 4 Call up installation wizard Call up the SDnetAssist installation wizard gt Programs gt Service gt SDnetAssist Step 5 Print and fill out network questionnaire Print out the network questionnaire on a printer i ee CK o connected to your Star Diagnosis system or access the network questionnaire in the INFO information system on your Star Diagnosis system or in the aftersales portal http aftersales mercedes benz com Click Next to proceed Schritt 113 Then have the questionnaire filled out by your IT administrator Step 6 Enter configuration data Now enter the network questionnaire data into SDnetAssist Follow the instructions for entering the data in SDnetAssist and fully complete the wizards Step 7 Disconnect cable connection Disconnect SDconnect from the Star Diagnosis system remove the connecting cable Once you have disconnected the wired connection the SDconnect configured is automatically selected and is shown in the SDnetControl deskband If this is not the case you will have to select the SDconnect in SDnetControl once again Connect SDconnect
14. factory settings delete the configuration details in Reset to factory setings section 3 5 Requirement Dconnect is not connected with a Star Diagnosis system 5X and confirm with f Abort an application Requirements Dconnect is not connected with the Star Diagnosis system An application is active Daimler AG Last updated 03 11 valid until revoked Technical Information Workshop equipment GSP Ol Page 14 of 35 HPC R800 D 70546 Stuttgart SDconnect Manual A Mercedes Benz 2 4 4 3 SDconnect operation status Boot process The Device is booting message appears during the boot process Standby The Device not in use message appears after booting Working status The name of the Star Diagnosis system connected followed by gt gt and a free text for the application is displayed when a connection is active OOO S42 gt caesar Sleep mode The current working status here sleep mode can be shown in the display Connection status The SDconnect display and the deskband are connected with each other The operating mode selection here Road Wireless Network must match in both displays Daimler AG Last updated 03 11 valid until revoked Technical Information Workshop equipment GSP Ol Page 15 of 35 HPC R800 D 70546 Stuttgart SDconnect Manual Mercedes Benz 3 Initial startup and configuration The following section describes the functi
15. of 35 HPC R800 D 70546 Stuttgart SDconnect Manual Mercedes Benz Step 3 Note the prompt to run self diagnosis SDconnect Toolkit Administration SDconnect self diagnosis You will now be asked whether you wish to run the self e 5 diagnosis with or without the SDconnect test adapter Do you want to execute the selftest with SDconnect You will now be asked whether you also wish to test the Selftestadapter recommended SDconnect keys display and buzzer Answer these questions yes or no according to your wishes The self diagnosis is run in accordance with your answer Please note If you do not have a self test adapter available in the workshop you can always order one as an accessory via the usual ordering channels Step 4 Printing the self diagnosis promee tere ee Dun Aue Fo ae EEKE TPO ee Gyre a a ES Pn ae ae P aapon The result is displayed in StarUtilities once the self diagnosis IENS aa is completed Sefdiagnostic You can print out the result with the Print function to send it ae to the Star Diagnosis User Help Desk UHD for instance Tout Resutcode 3 Testresult 0 Number of errors 1 Number of wamings 0 SOconnect Toolkit device dagnostic Deviceinformation SeridNumber 102157 ColorNumber 01 DetectFlag OFF CSD 1 21 20090519 BOOTIMAGE 1 6 20070611 UBOOT 1 0 3 CAESAR 0 3 0 PIC 27 20090304 WLANDRY 0 1 20060128 LKM_GPIO 1 0 20090513 et a I
16. until revoked Technical Information Workshop equipment GSP Ol Page 32 of 35 HPC R800 D 70546 Stuttgart SDconnect Manual A Mercedes Benz Cleaning SDconnect Clean your SDconnect at regular intervals Observe the following instructions when doing so Use a cloth slightly dampened with a mild cleaning agent to clean the outside of the unit Do not use solvents Use a standard spirit alcohol based glass cleaner Spray the liquid onto the cloth and not directly onto the unit Paint thinners such as cellulose thinners acetone or similar or scouring pastes detergents and paint cleaners are unsuitable for cleaning the unit These substances will damage your SDconnect housing and the control panel 7 5 Tasks for SDconnect return If you intend to return your SDconnect it must be prepared for return shipment as follows Ensure that The rechargeable batteries are removed from the system and the closing mechanism for the battery compartment has been properly closed again see section 2 2 The wireless card WLAN card and memory card SD card are removed from the system see section 2 The cover flap is properly closed see section 2 The number clips stay in your workshop The charging adapter test adapter and all cables supplied stay in the workshop The configuration settings in SDconnect are deleted see section 3 5 The return label is filled out completely see User manual Daimler AG Last updated 03 11 v
17. your Star Diagnosis system Problems with the application software in the Star Diagnosis system and SDconnect Questions from users How can the function What is to be done if etc The support for vehicle specific questions will be provided as usual by the familiar support functions Information required by the Star Diagnosis User Help Desk UHD when taking on a problem The Star Diagnosis User Help Desk UHD requires the following information from you every time you call Your dealer number Your name Your current telephone and fax number The system number of your Star Diagnosis system including SDconnect An exact a description of the problem as possible The Star Diagnosis User Help Desk UHD will clarify together with you further information on the software installed version no and release no as well as software and hardware error message s Access to the Star Diagnosis User Help Desk UHD The Star Diagnosis User Help Desk UHD is available to you in the languages and times listed below Mon Fr Sat Time zone Star Diagnosis Hotline UHD English English French Italian Spanish Japanese Fax Daimler AG Technical Information Workshop equipment GSP Ol HPC R800 D 70546 Stuttgart 06 00 22 00 07 00 22 00 07 00 22 00 08 00 23 00 23 00 14 00 07 00 22 00 06 00 14 00 00 00 24 00 07 00 14 00 07 00 14 00 09 00 16 00 23 00 10 00 07 00 18 00 00 00 24
18. 0AAHC Daimler AG Last updated 03 11 valid until revoked Technical Information Workshop equipment GSP Ol Page 10 of 35 HPC R800 D 70546 Stuttgart SDconnect Manual A Mercedes Benz 2 3 2 4 Safety information for batteries Always use six batteries identical with respect to capacity brand life charge level Only use the models recommended above or check that the batteries you use meet the criteria above Use rechargeable batteries not disposable batteries or dry batteries Please take care that the batteries are inserted with the correct polarity Incorrectly inserted batteries may lead to damage or faults in the unit Ensure that the batteries are disposed of properly Please also note the instructions in section 2 3 2 5 regarding the Forming and charging process for rechargeable batteries Charge the batteries fully before use Run through the 14 hour forming cycle completely when the unit is used for the first time 2 3 2 5 Forming and charging process for rechargeable batteries Depending on the condition of the batteries a forming cycle or the regular shorter charge cycle is started for charging The forming cycle begins if the batteries are new have been exchanged or completely discharged The SDconnect batteries must then be charged for 14 hours continuously Connect the SDconnect to an external power source to charge the batteries a using the vehicle connection cable b the charging adapter test ad
19. Ol Page 34 of 35 HPC R800 D 70546 Stuttgart SDconnect Manual A Mercedes Benz Nicaragua The Netherlands Northern Cyprus Norway Austria Poland Portugal Romania Sweden Switzerland Slovak Republic Slovenia Spain South Africa Czech Republic Turkey Hungary USA West Bank Cyprus The following certificates are available for the WLAN card D Link AirPlus XtremeG DWL G650 EN 300382 v 1 4 1 2003 4 EN 300382 2 v 1 2 1 2001 12 EN 301489 1 v 1 4 1 2002 8 EN 300382 17 v 1 2 1 2002 8 EN 5502 1998 A1 2000 A2 2003 class B EN 61000 3 2 2000 EN 61000 3 3 1995 A1 2001 EN 60950 3 edition 2000 IC RSS 210 Issue 5 with amendment November 30 2002 IC RSS 210 Issue 5 clause 6 2 2 0 FCC 47 CFR Part 15 subpart C Daimler AG Last updated 03 11 valid until revoked Technical Information Workshop equipment GSP Ol Page 35 of 35 HPC R800 D 70546 Stuttgart SDconnect Manual
20. alid until revoked Technical Information Workshop equipment GSP Ol Page 33 of 35 HPC R800 D 70546 Stuttgart SDconnect Manual A Mercedes Benz 8 Certificates 8 1 SDconnect Certificates The currently valid versions of the necessary documents according to the respective certification systems are available for the following certificates of conformity Electromagnetic compatibility CE conformity USA Federal Communications Commission FCC Statement cUL Certification GOST Certification MIC EMC Certification e Mark Certification VCCI Certification Drop test according to ISO 16730 3 chap 4 3 In urgent situations copies of the current documents can be requested 8 2 WLAN Certificates Existing certificates are listed plus those countries in which the card is certified for wireless operation Please check the area of validity of the certificates listed below at the relevant authorities in your country D Link AirPlus XtremeG DWL G650 Rev C D Link AirPlus XtremeG DWL G650 Rev C Country Comment Algeria Austr Oceania o Australia o Azores i O Belgium o Bulgaria Denmark o Germany 0 Estonia Finland France Gaze Greece Great Britain O dreland o deeland dtaly Japan Yemen Canada Canary Islands o Latvia o O ibys lithuania Luxembourg 0 Madeira Malta New Zealand Oceania O OOO New Zealand O O Daimler AG Last updated 03 11 valid until revoked Technical Information Workshop equipment GSP
21. apter and the power supply unit of your Star Diagnosis system ea eae A fully completed forming cycle is a prerequisite for a failure free operation and faster regular charging cycle The current charging cycle is shown in the SDconnect display 14 hours battery fully charged gair Charging in the forming cycle Charging in the regular cycle _ Note Ensure that the rechargeable batteries in both units Star Diagnosis system and SDconnect are fully charged before using the system Never interrupt the 14 hour forming cycle Every interruption restarts this cycle Daimler AG Technical Information Workshop equipment GSP Ol HPC R800 D 70546 Stuttgart Last updated 03 11 valid until revoked Page 11 of 35 SDconnect Manual Mercedes Benz 2 3 3 SD memory card optional 2 3 3 1 Installing and removing memory cards Once the cover has been removed the SD memory card can be removed from the slot by pulling on it gently There is no click mechanism The card is inserted by pressing it in gently Please note the installation direction the slanted corner must be pointing upwards or towards the WLAN card 2 3 3 2 Safety information for memory cards 2 4 SDconnect control panel The control panel permits direct interaction with the SDconnect such as calling up information or setting parameters for the device In general the SDconnect is controlled using the Star Diagnosis system
22. card optional Maximum capacity 2 GB 2 3 1 WLAN card 2 3 1 1 Removing and installing the WLAN card Once the housing cover has been dismantled the WLAN card can be removed from the slot by pulling on it gently The card is inserted by pressing it in gently Please note the installation direction the LEDs have to be facing in the direction of the display Please make sure that the WLAN card is in working order and has no external damage or dirty contacts A damaged or defective WLAN card can lead to damage or malfunctions within the unit 2 3 1 2 WLAN card specifications Last updated 07 2007 D Link AirPlus XtremeG DWL G650 Rev C Only use the unit with approved WLAN cards The use of other card types can lead to damage or malfunctions within the unit Current information about recommended WLAN cards and approvals can be found in the After Sales portal http aftersales mercedes benz com 2 3 1 3 Safety information for WLAN cards Daimler AG Last updated 03 11 valid until revoked Technical Information Workshop equipment GSP Ol Page 9 of 35 HPC R800 D 70546 Stuttgart SDconnect Manual A Mercedes Benz 2 3 2 Rechargeable batteries 2 3 2 1 Removing the transport protection The batteries have an easily removable transport protection that projects from under the cover and stops the electrical circuit from being completed accidentally during transportation Simply pull out the yellow strip before you use the
23. edeessaeecoseaueencesseaceussaetavoevaa 19 5 SDCOMMECT TOON srren aranne IE EENAA 20 5 1 Calling up the SDconnect Toolkit snessnessesseessesseessesseessesseessesseesseseesseeseessessseessessessressesseessesseeseesseesessreseesseessessseeses 20 Oz Configuration of SDconnect with SDconnect ToolKit ee ssssssessecssscsescessecsssceseecessscesseesseessesessesseseeseeseneneass 20 Testing the operability of SDconnect in the workshop WLAN network ssseseesseessesseessessessessessssessessesssessreseesseeseesseeseeseeses 23 5 3 Display of detailed information with SDconnect ToolKit ee ccscssssccssessscssscessseessseesseecsseessaeseseecesesessecsaeeesees 24 5 4 Performing a guided self diagnosis secrctari ainsana ro e eA EEA NOA ENAR EE EAN EAER NAR EES anata 25 5 9 Updating the software with SDconnect TOGIKIL ws lt vsciencerseeasirnnneventcanaesemiveadesantsecneachnecthsebenseceeseorioamiuasiainemivrad 27 6 Help in the event of an errOr sssssesccoesssssececcsssseeccccssssecececeossssececcsssseseeecssseeeecsssseceecsesssseeecooecssseeeeeossseeeeeeesese 28 6 1 PA EE E E E EEE 28 6 2 Star Diagnosis User Help Desk UHD essessneesesseessesseessesseessesseessessesseeseessesseesseessesssessesseessesseeseesseeseesseseesseessesseesses 30 7 Warning instructions and operating instructions sssseescocsssseccccsocssssececososseeecocoseeceocssssececososseeecocosssseseseeo 31 7 1 EE E E E E E AE EE E A A AE E nade T EE E 31 7 2 So
24. es are usually not necessary If newer software packages are available for the SDconnect selected the unit is updated automatically when a connection with the Star Diagnosis system is set up ee a Daimler AG Last updated 03 11 valid until revoked Technical Information Workshop equipment GSP Ol Page 27 of 35 HPC R800 D 70546 Stuttgart SDconnect Manual A Mercedes Benz 6 Help in the event of an error For errors that prevent you from continuing your work please call the Star Diagnosis User Help Desk UHD on the usual number see chapter 6 2 Before calling the User Help Desk read the Frequently Asked Questions FAQ to keep the processing of queries to a minimum Please consult your local IT support for matters relating to your workshop network 6 1 FAQ List Hardware fault Description solution Display blank is no longer lit Connect the external power supply then check the LEDs light up do not light up If OK with power supply battery is faulty the batteries must be replaced purchase from specialist retailer If not OK with power supply the display is faulty have SDconnect exchanged through the Star Diagnosis User Help Desk UHD Buttons are pressed but no input SDconnect is faulty Exchange required contact Star Diagnosis User Help Desk UHD Battery Check battery management if necessary perform formation cycle If this does e g runtime restricted not work replace the batteries pu
25. ine is running The Star Diagnosis system must be kept at least 13 cm 5 12 inches away from electrical equipment that has a strong magnetic field e g motors magnets television sets refrigerators and large loudspeakers Only authorized persons are permitted to carry out maintenance and repairs Avoid liquid splashes water acids solvents Only use the SDconnect at temperatures of between 0 C and 45 C Operating the system outside of this temperature range can cause damage or malfunctions within the unit SDconnect contains sparking components e g relays and therefore may only be operated at a height of at least 46 cm 18 inches above the ground Daimler AG Last updated 03 11 valid until revoked Technical Information Workshop equipment GSP Ol Page 31 of 35 HPC R800 D 70546 Stuttgart SDconnect Manual A Mercedes Benz Do not expose the SDconnect to direct sunlight Do not drop the SDconnect Only supply SDconnect with power from the vehicle via one of the vehicle connection cables provided for this use or via the charging adapter test adapter and the power supply unit of the Star Diagnosis system concerned The use of other power supply sources that are not intended for this use can cause damage or malfunctions within the unit Only operate the SDconnect keyboard with your fingers and never use sharp or pointed objects Be careful not to damage the plastic cover of the liquid crystal display with sharp or poi
26. l instructions in the literature supplied with the unit before you use the SDconnect The unit must not be set up near an open flame Never use the system components close to an open flame or chemical liquids Only use the system components that were supplied together with the SDconnect or that correspond to the specifications for exchangeable elements Please observe the descriptions in the user guidelines that are supplied with the unit and via the INFO information button on your Star Diagnosis system The unit may only be handled according to the manufacturer instructions as otherwise the safety may be impaired You must not carry out any repairs required Please consult the Star Diagnosis User Help Desk UHD Let all parts cool down before you transport them The system must not be cooled using additional means In order to prevent electrical damage the system may not be used on a damp surface or in the rain Never open your SDconnect The exception is the cover which may be removed to allow replacement of the battery and the WLAN card Please observe the instructions described in section 2 Perform all work in the engine compartment when the engine is not running and the ignition is switched off Danger of injury due to rotating or hot parts When performing necessary checks on running engines route the test lines outside the engine area To prevent poisoning ensure sufficient ventilation when working on a vehicle while the eng
27. nted objects Carry the unit by the strap intended for this use and not by the connection cables The Ethernet cable and vehicle connection cables must never be routed over tables benches or cabinets They must be kept clear of all hot objects and rotating parts To prevent explosion or fire never operate the device near open fuel containers Fluctuations and deviations of the AC voltage outside of the permissible tolerance could lead to function failures and to irreparable damage of electronic components The unit should be switched off in the evening or for longer breaks gt 4 hours to minimize the power consumption Standard spirit alcohol based glass cleaner can be used to clean the screen and other components Rough sharp edged and damp wet cleaning tools are not permitted Only clean the screen with a soft dry cloth Do NOT use solvents for cleaning The unit must be stored and transported in the transport case provided for this purpose Do not disassemble the SDconnect into its parts The SDconnect may only be switched on once it has adjusted to room temperature Condensate in the unit can cause damage Information on wired connections Only use the SDconnect with the cables and adapters provided Check the condition of the cables before connection Use of modified cables or cables that are not intended for the unit can lead to damage or malfunctions within the unit Damaged broken or bent pins in the plugs can lead
28. off off Loss of WLAN reception in infrastructure lights up Loss of external power supply lights up Battery discharged on flashes slowly flashes slowly flashes fast once long once briefly three times briefly Key finder activated flashes fast flashes fast three times long Flight recorder off on off 2 4 4 Information in the display 2 4 4 1 Information button mm f l am O Car battery 14 0 mm f l am O Mame 30 Serial number 100082 Displays the internal workshop name matches number clip saved in the device and the SDconnect serial number Enn J I Os 1 7 20060330 CSE 1 17 200701 30 Displays the SDconnect software version number Daimler AG Technical Information Workshop equipment GSP Ol HPC R800 D 70546 Stuttgart Last updated 03 11 valid until revoked Page 13 of 35 SDconnect Manual A Mercedes Benz TRO Wanhiac OO 0F 50 40 0D E9 1 x Se and confirm with _ mn A ty eae ere Manual WLAN mode change from road wireless network to Change WLAN mode a Change WLAN mode A z workshop wireless network and vice versa Requirements WLAN card installed WLAN mode active No wired connection used 2X oN and confirm with ao Powering the SDconnect down standby Requirements Dconnect is not connected with the Star Diagnosis system No external power supply connected 3 x Sel and confirm with Reboot SDconnect 4 x Ase and confirm with Reset to
29. ons that can be called up directly via the SDconnect keypad 3 1 Cable operation Setting up without configuration process It is possible to use your Star Diagnosis system directly without a connection to an IT network out of the box To do this you must use the Star Diagnosis connection cable to the SDconnect multiplexer green cable Step 1 Start Star Diagnosis system Start your Star Diagnosis system by pressing the ON key on the front panel Step 2 Connect SDconnect Connect the SDconnect to the Star Diagnosis system with the green connection cable and connect the SDconnect to the vehicle e g with the OBD cable The system is now ready to use 3 2 Wireless operation Setting up with the SDnetAssist configuration wizard A fully functioning operation is possible only within a network For this some settings must be applied on the Star Diagnosis system and on the SDconnect In addition if required the Star Diagnosis system and SDconnect must be activated for operation in the network The MAC addresses must be enabled if MAC authentication is being used Please note the instructions in section 3 4 Step 1 Start Star Diagnosis system Start your Star Diagnosis system by pressing the ON key on the front panel Step 2 Connect SDconnect Connect SDconnect to the Star Diagnosis system using the connecting cable green cable Daimler AG Last updated 03 11 valid until revoked Technical Information Workshop
30. ontrol units can be increased by SDconnect depending on the vehicle model series and number of control units Reliable combination The user controls SDconnect via the Star Diagnosis system The central software on the diagnostic system SDnetControl combines all the important functions for operating the SDconnect wireless multiplexer such as information configuration self diagnosis and software updates In addition SDconnect offers a display four control buttons and two LED displays for information on the current operating condition An acoustic signal warns the user if he is leaving the wireless range of the workshop with the mobile unit The unit s self diagnosis capabilities have also been improved This enables the user to better detect possible malfunctions of the multiplexer Simple application The Star Diagnosis SDconnect multiplexer is easy to operate thanks to its compact dimensions of 22 x 16 x 5 cm The wireless connection to the diagnostic device affords maximum mobility SDconnect is easy to use and does not require time consuming familiarization The new configuration wizard SDnetAssist guides the user through setting up the Star Diagnosis system and SDconnect for wireless operation Operation without a wireless connection is also possible The units are preconfigured for non wireless operation and can be operated at any time using the connection cable included in the scope of delivery Complete model series coverage The Sta
31. pdated 03 11 valid until revoked Technical Information Workshop equipment GSP Ol HPC R800 D 70546 Stuttgart Page 18 of 35 SDconnect Manual 4 Operation Daimler AG Technical Information Workshop equipment GSP Ol HPC R800 D 70546 Stuttgart Mercedes Benz 5 SDconnect Toolkit You can configure the SDconnect without the installation wizard using the SDconnect Toolkit application The software also offers the option to display detailed information on SDconnect and to complete a self diagnosis or a manual software update 5 1 Calling up the SDconnect Toolkit Step 1 Call up program SDnetControl Launch the SDconnect Toolkit via SDnetControl en 6 0 3 Connections Select MUX Configuration Network tools LDSDnetControl Network Server Profile Configuration MUX Step 2 Select menu entry SDnetControl x Version 1 6 0 3 z Connections Select MUX Network tools The following program overview appears This menu serves i ee i Info Network Profile as a starting point for the descriptions in the following sections 5 2 Configuration of SDconnect with SDconnect Toolkit Daimler AG Last updated 03 11 valid until revoked Technical Information Workshop equipment GSP Ol Page 20 of 35 HPC R800 D 70546 Stuttgart SDconnect Manual Step 1 Select menu entry Click on the Configuration gt MUX tab in SDnetControl to configure the SDconnect Then click on Register configure
32. r Diagnosis SDconnect Facelift multiplexer recognizable by its matt silver sticker with the SDconnect Facelift inscription on the rear also supports TCP IP protocols and thus ensures communication with the new control units via Ethernet All older model series can also be diagnosed with it in the usual way In addition all European Mitsubishi Canter vehicles Euro 3 4 5 and LIFT can be diagnosed with the old and the new SDconnect The cable required for this can be ordered as an accessory in the usual way Daimler AG Last updated 03 11 valid until revoked Technical Information Workshop equipment GSP Ol Page 4 of 35 HPC R800 D 70546 Stuttgart SDconnect Manual A Mercedes Benz 2 Hardware SDconnect s product characteristics are presented in the following section 2 1 Connection options 2 1 1 Connection options on SDconnect Connection to a Star Diagnosis system Connection to a vehicle test adapter a charging adapter The vehicle cable is connected to SDconnect using The connecting cable charging adapter is a push pull mechanism connected to SDconnect using a folding mechanism a P ee he The red ring on the connector shows whether or not the connector is engaged Engaged Red ring is not visible Detached Red ring is visible 2 1 2 1 Wired connection to Star Diagnosis compact w The rear LAN interface on the Star Diagnosis The LAN interface on the side of the Star Diagnosis
33. rchase from specialist store or Check batteries shows in the If Check Batteries is displayed contact Star Diagnosis User Help Desk UHD SDconnect display SDconnect cannot be switched off This is not an error It is not possible to switch SDconnect off completely display blank SDconnect can only be switched to the standby mode Software fault Description solution Example symptom diagnosis no longer possible following upload of the Star Diagnosis Update DVD Test steps Install current add ons Check whether the current add ons Check the cable fit are present Check system status in Star Utilities or Star Check in SDnetControl Check configuration in SDnetAssist Check configuration in SDnetControl for the Star Diagnosis system in the Configuration gt Network tab gt Compare with the SDnetAssist questionnaire Check configuration in SDconnect Toolkit for the SDconnect gt in SDnetControl Configuration gt MUX gt Information tab Compare with the SDnetAssist questionnaire If not effective contact Star Diagnosis User Help Desk UHD Communication error Description solution No communication with the vehicle Check all the cable connections in use Check whether the SDconnect is ready for operation Check the settings for the wireless connections Configuration and whether Check configuration in SDnetControl Check configuration in SDconnect Toolkit the WLAN card is enabled in your Star Diagnosis
34. rne Ne S DCONNE 6 eri ere cere rene rerrnTe trantne cr EA ee rrre eererre nn er tre 31 73 EGF OM ofthe SING i eerren ANA EE EENE E AEA 31 7 4 Re AIS EAS ONS Ca we cmsies psn tenscroion heatotan EEE E E TAE E E geen ioussstadneceena ss 33 7 9 TISS MON GO IMSL WC UU Tara nE TAN T tena eau saen use ET 33 BGP CACC S TE OE E AE T AE AE O ON 34 8 1 COMMS CL Caricate S aea T S T NT AG 34 8 2 WEAN CONCI E ria A E E sarmansvntoseareuatereints 34 Daimler AG Last updated 03 11 valid until revoked Technical Information Workshop equipment GSP Ol Page 2 of 35 HPC R800 D 70546 Stuttgart SDconnect Manual A Mercedes Benz Change history Date Section 07 O7 02 07 07 ie 03 08 a Ss Version Change description 1 0 Completion 1 1 Certificates and WLAN card Tasks for SDconnect return added 1 3 A 1 5 2 0 2 1 Added the types of wireless connection road wireless network workshop al wireless network 1 03 04 08 Ha Insertion of Star Diagnosis compact content Deletion of section 3 6 Configuration with SDconnect Toolkit 1 0 42 Insertion of section 5 SDconnect Toolkit 2 0 2 Updating of certification of WLAN cards 2 0 Updating to account for SDconnect Facelift lt 2 1 Updating of screenshots of the applications and CI Daimler AG Last updated 03 11 valid until revoked Technical Information Workshop equipment GSP Ol Page 3 of 35 HPC R800 D 70546 Stuttgart SDconnect Manual A Mercedes Benz
35. s linked to the workshop s wireless network Neto screen 28 25 255 0 ateway with WLAN parameters workshop D etnik rane zea WEP ASCII 192 168 10 123 Check the white check box next to WLAN parameters 255 255 255 0 toad24h workshop to open the dropdown menu and to enable the wer aso input boxes You can obtain the data you need to enter from your IT administrator Input fields Step 4 Enter road WLAN parameters SDconnect Toolkit lExample Administration s s f Infomation Flegister eonfiguie ell diagnosis Software update Your SDconnect sets up direct wireless communication with Ee fo mms fete your Star Diagnosis system using the WLAN parameters ana Serial number 57222 WLAN mode No WLAN road For this purpose an ad hoc network road wireless WLAN regina seting WORLD z E EM WLAN parameters workshop network is set up without a corresponding IT infrastructure oa ee access point Nets aeren IE 0 SSID network name werkstatt Encryption WEP ASCII Please enter the following data in the input mask to FESR Wa panei IP address 192 168 10 123 configure your SDconnect for the road wireless network 1 eee Ca SSID network name i Encryption WEP 7 ASCII Key E M LAN parameters nuro Input fields oe Network screen SSID network name Encryption Key Ss SS
36. sis system must have been established Step 3 Read out information There are two different areas G This area contains all configuration parameters for the SDconnect selected such as its name its serial number wireless mode configured etc This is where your find the version number of the SDconnect Toolkit the serial number of the Star Diagnosis system and the versions of the hardware and software You can print out the configuration settings of the SDconnect selected by clicking on Print Daimler AG Technical Information Workshop equipment GSP Ol HPC R800 D 70546 Stuttgart SDnetControl Connections Info Select MUX Network Configuration Server Information Register confiqure self diagnosis Software update Yersion 1 6 0 3 Network tools Profile Administration 05 7 Cable Ac Mercedes Benz Register configure Self diagnosis Software update E General information Name Serial number Working state WLAN mode WLAN regional setting Last used Power supply Hardware Status WLAN parameters workshop WLAN parameters road LAN parameters E Tester information Toolkit version Tester name IP Multicast UDP Broadcast Hardware version Software versions 23 57222 Accessible No WLAN WORLD 0 days ago Vehicle OK Mercedes Benz linfermation Recister configure Self diagnosis Software update E General information ame
37. splay Press 4x The SDconnect is ready for work if you can see the WLAN IP address in the display The SDconnect is not ready for work if you can see a WLAN status or WLAN error message in the display Please contact the Star Diagnosis User Help Desk UHD in this case Daimler AG Technical Information Workshop equipment GSP Ol HPC R800 D 70546 Stuttgart Mercedes Benz Information Register configure Self diagnosis Software update SDconnect Files for software update Update2536 CaesarEngine090 zip WLanRoamingDisable25 zip WlLanRoamingE nable25 zip Progress am 2 WLAN IP 192 169 168 21 Last updated 03 11 valid until revoked Page 23 of 35 SDconnect Manual 5 3 Display of detailed information with SDconnect Toolkit Please note that the external power supply e g charging adapter test adapter must be used in order to display the SDconnect information A wired connection is not required Step 1 Select menu entry Click on Information in the Configuration gt MUX tab in SDnetControl Step 2 Select SDconnect On the left of the window you will see a list of all known SDconnect units devices that have logged into the system at some point Click the desired SDconnect to have its configuration displayed The SDconnect selected is highlighted in blue The SDconnect must be reachable for this to be possible i e a wired or wireless connection to the Star Diagno
38. ssanshwossdotsieasensqagusneeaviesascutsueoisnanveeeaeats 10 2 9 3 SD memory card optional ssesseessessesssessesseessessseseesseeseesseeseessessesseessesseesssessessssssessesssessessresseeseesseseesses 12 2 4 SDconnect control panel ss esoseeseesseeesesesseesseesseesseesseesssesssesssesseesseessoessresessessoeessessseesseesssesseessseeseessoesseeseeessoresseesnes 12 2 4 1 IAIN GOIN oenn ARE A A E E E 12 2 4 2 Display OU IN and ICONS rr E A carne sneetoaierarenteineueiianes 13 2 4 3 EEP i aC O a E E EE A E 13 2 4 4 Miormaton IN HAS display erence e A E 13 3 Anitial Stamtup ANG CONTMEUNAUION sscescscasencvessssncceccscareancavesanaacensoversiacnearesanneussusesareenvacecerecsesacanssannsinects eieneersetenneas 16 3 1 Cable operation Setting up without configuration PFOCESS cccscccsssessecesecssscsseeesssecssecsssecsseessseeesseesseeesseeees 16 OZ Wireless operation Setting up with the SDnetAssist Configuration wizard essessesssessesssessesssessesssessesseese 16 3 9 Wireless operation Setting up using the SDconnect Toolkit Expert tool 0 0 ee eeeceseesseesseeessecssseessseeseeeesees 17 3 4 Reading oUt MAC addresses eeen TE EEEE 18 3 5 Resetting to factory settings deleting the configuration essesseessessesssessessesseessesseessssssessessressessressesseesseesesseeses 18 4 OpErIUON ssasiviscaccavsasansecesoecewenseiicdoadvandsunsvissidesess vavensvsctesdsawescunocscdaveasawedanss cisoadsdaswiasbauisav
39. system SDnetControl Run a self diagnosis through the SDconnect Toolkit Contact the Star Diagnosis User Help Desk UHD Daimler AG Last updated 03 11 valid until revoked Technical Information Workshop equipment GSP Ol Page 28 of 35 HPC R800 D 70546 Stuttgart SDconnect Manual A Mercedes Benz No connection between Star Diagnosis system and SDconnect despite the cable being connected No connection to the control units in the vehicle Error message 503 9755 11005 appears No wireless connection between Star Diagnosis system and SDconnect MUX connection error Error code 1 2 503 9901 Permanent display of the cable icon in the SDconnect display Workshop wireless network road wireless network cannot be selected in SDnetControl WLAN signal strength insufficient Daimler AG Check cable e g swap with another unit cable firmly connected If the connection works with another cable cable is faulty Order new cable on accessories form If the connection does not work with another cable Run SDconnect self diagnosis Then contact the Star Diagnosis User Help Desk UHD and send the self diagnosis to the Star Diagnosis User Help Desk UHD Start the SDconnect Toolkit via SDnetControl Select Software Update Highlight the ClearCeFlashDisk zip update package and then start the update The SDconnect data contents are reset similar to recovery on the Star Diagnosis System This may have many causes e g
40. ta ieee 0 100 iF Daimler AG Last updated 03 11 valid until revoked Technical Information Workshop equipment GSP Ol Page 26 of 35 HPC R800 D 70546 Stuttgart SDconnect Manual A Mercedes Benz 5 5 Updating the software with SDconnect Toolkit Please note that the SDconnect external power supply e g charging adapter test adapter must be used in order to update the software A wired connection is not required Step 1 Select menu entry SpnetControl l S n ersion iI b U Connections Select MUX Configuration Network tools Click on Software update in the Configuration gt MUX window in SDnetControl Info Network Server Profile Step 2 Select SDconnect CC Mercedes Benz On the left of the window you will see a list of all known Sa CE M SDconnect SDconnect units devices that have logged into the system nme E23 at some point mM Files for software update Simply click on the SDconnect you wish to update The SDconnect must be reachable for this to be possible i e a wired or wireless connection to the Star Diagnosis system must have been established Poges Step 3 Select software update package Dco Mercedes Benz Administration All available software update packages are shown here toes epee aire Soames Select the package supplied and then click on Start The new software will now be transferred to the SDconnect lt lt Note Manual updat
41. the battery compartment WLAN card SD memory card The SDconnect can be opened to access the battery compartment WLAN card and the memory card Please note the relevant operating instructions and warning notices 2 2 1 Removing the cover To remove the cover flap you require a size TX 20 Torx screwdriver The cover flap can be opened once the two screws A and B fastening it have been removed Please be aware of the two rubber cushions on the inner side of the cover flap these fix the WLAN card and SD memory card if present in place when the lid is closed and are inserted ex works Do not change their position 2 2 2 Screw dimensions The screws have the following dimensions Locatio Model n Gaer Torx round head top A SN6404 steel p 8 8 galvanized Cover Torx round head bottom SN6404 steel B 8 8 galvanized Battery Torx round head compart SN6404 steel ment C 8 8 galvanized Important If you lose any of the screws use only replacement screws from specialist stores that meet these specifications exactly Daimler AG Last updated 03 11 valid until revoked Technical Information Workshop equipment GSP Ol Page 8 of 35 HPC R800 D 70546 Stuttgart SDconnect Manual Mercedes Benz 2 3 WLAN card batteries and SD memory card in SDconnect Rechargeable Batteries AA mignon 1 2 V NiMH Minimum capacity 1700 mAh WLAN card D Link AirPlus XtremeG DWL G650 SD memory
42. to damage to the vehicle unit and can negatively affect the user s health Only authorized network and power cables may be used Defective cables and broken or damaged system components may not be used Do not use SDconnect with defective cables or after damage e g dropping until they have been inspected serviced by the personnel authorized to do this Never pass cable connections over sharp edges or corners and never let them come in contact with hot or moving vehicle components If extension cables are needed only use suitable cables that are authorized for the power input as unsuitable connections can overheat and cause fires Take care that all cables are routed properly so that there is no danger of tripping and that no possible damage can be caused during general working in the workshops Remove electrical connections from the power supply when they are not in use Never pull on the cable to pull out a plug pull on the plug itself Check that the unit is grounded Connect the power cable to a properly grounded socket Do not lay adapter or connection cables in close proximity to hot parts Danger of damage Do not route adapter or connection cables close to parts carrying a high voltage May cause interference In order to prevent electric shocks no cable can be connected or disconnected during a storm and installation maintenance or reconfiguration work may also not be carried out Daimler AG Last updated 03 11 valid
43. to the vehicle The system is now ready to use 3 3 Wireless operation Setting up using the SDconnect Toolkit expert tool Wireless configuration can also be carried out using the SDconnect Toolkit expert tool Details for this can be found in section 5 Daimler AG Last updated 03 11 valid until revoked Technical Information Workshop equipment GSP Ol HPC R800 D 70546 Stuttgart Page 17 of 35 SDconnect Manual A Mercedes Benz 3 4 Reading out MAC addresses If your IT network uses MAC authentication the SDconnect s MAC address must be enabled by your IT network administrator Step 1 Read out SDconnect MAC address a ma The WLAN card MAC address is shown in the came SDconnect display when the i button is pressed four times if a WLAN card is fitted in the unit Maniac O0 0F 30 40 00 E9 Step 2 Read out Star Diagnosis system MAC address Three MAC addresses 2x LAN 1x WLAN are printed on the back of the Star Diagnosis system 3 5 Resetting to factory settings deleting the configuration Step 1 Call up menu entry 4x Se and confirm with Calling up the Reset to factory settings prompt Step 2 Confirmation i ing Confirm query again by pressing _ Step 3 Reconfirmation Sf Press and simultaneously for 3 seconds Hold and for 3 seconds SDconnect emits an acoustic signal and restarts The process can be canceled at any time by pressing x Daimler AG Last u