1. PROGRAMMING P66E 4E RADIO SUPERVISION ALERTS SIREN OUTPUT PROGRAM MODE LEVEL Setting this option turns the Siren output ON when a SUPERVISED RADIO alert Installer Remote by PC occurs The Siren output will remain ON for the duration of the ALARM TIME FACTORY DEFAULT Set by Option P295 OFF Supervision Siren output disabled PROGRAMMING SEQUENCE NOTES RELATED OPTIONS P66E toggles the option ON and OFF P65E Supervised Radio Zones P66E 4E OFF Supervision Siren output disabled P66E 4E ON Supervision Siren output enabled RADIO SUPERVISION ALERTS AUX1 OUTPUT PROGRAM MODE LEVEL Setting this option turns the AUX1 output ON when a SUPERVISED RADIO alert Installer Remote by PC occurs FACTORY DEFAULT OFF Supervision AUX1 output disabled PROGRAMMING SEQUENCE NOTES P66E 5E toggles the option ON and OFF e AUX1 output is Pin1 on the J3 header on P66E 5E OFF Supervision AUX1 output disabled the main board P66E 5E ON Supervision AUX1 output enabled RELATED OPTIONS P65E P66E 6E RADIO SUPERVISION ALERTS AUX2 OUTPUT PROGRAM MODE LEVEL Setting this option turns the AUX2 output ON when a SUPERVISED RADIO alert Installer Remote by PC occurs FACTORY DEFAULT OFF Supervision AUX2 output disabled PROGRAMMING SEQUENCE NOTES P66E GE toggles the option ON and OFF AUX2 output is Pin2 on the J3 header on P66E 6E OFF Supervision AUX2 output disabled the main board P66E 6E
2. L 51mm J RED N C Vibration BLUE contacts 20mm YELLOW N C Tamper GREEN J loop 350mm cable 4 829 m 0 36mm 2xg3mm holes 1 at 27mm spacing NESS D8 V4 CONTROL PANEL INSTALLER MANUAL PROGRAMMING ZONE ASSIGNMENT Zones OPTION No DESCRIPTION 1 2 3 4 5 6 7 8 Double Trigger zones Instant zones DELAY GROUP Entry Delay 1 zones Only one option allowed per zone Handover zones PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT all OFF No Double Trigger zones NOTES Double Trigger is useful for preventing unwanted alarms from zones in harsh environments such as sheds and garages OE will turn all selections OFF Entry Delay 2 zones Lockout zones Area 1 zones Area 2 zones Monitor zones 24Hr zones Day zones ON Factory default setting DOUBLE TRIGGER ZONES Zones programmed to Double Trigger will recognise an alarm condition if The zone has been triggered twice within a 4 minute period If any 2 zones both programmed for double trigger each trigger once The zone is left unsealed for longer than 15 seconds PROGRAMMING SEQUENCE P39E Zone No E toggles the options ON and OFF P39E Zone No E OFF The zone is not a Double Trigger zone P39E Zone No E ON The zone is a Double Trigger zone MEMORY E will turn all selections ON PROGRAM MODE LEVEL
3. S S ES OPTION No DESCRIPTION 1E 2E 3E 4E 5E 6E 7E 8E Montor amp Day mode ON Factory default setting MONITOR MODE OUTPUT MAPPING This option selects which outputs are triggered by alarms in Monitor Mode PROGRAMMING SEQUENCE P63E 1E 4E toggles the options ON and OFF PROGRAM MODE LEVEL P63E 1E Monitor Mode to Reset output Installer Remote by PC P63E 2E Monitor Mode to Strobe output P63E 3E Monitor Mode to Keypad Sonalert output FACTORY DEFAULT 1E 4E OFF No Monitor Mode outputs P63E 4E Monitor Mode to Siren output S Lj E NOTES RELATED OPTIONS P64E 1E 2second Monitor alarm DAY MODE OUTPUT MAPPING This option selects which outputs are triggered by alarms in Day Mode P63E 5E 8E PROGRAMMING SEQUENCE P63E 5E 8E toggles the options ON and OFF PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 5E 6E ON TE 8E OFF P63E 5E Day Mode to Reset output P63E 6E Day Mode to Strobe output P63E 7E Day Mode to Keypad Sonalert output P63E 8E Day Mode to Siren output NOTES RELATED OPTIONS P64E 2E 2second Day alarm MONITOR Mode and DAY Mode Output Mapping is an extra feature released with the D8 V4 Note that MONITOR and DAY zones do not automatically assume the outputs assigned by Options P54E P59E Those options only apply to zones when the panel is in the ARMED state Options P63E 1E 8E allow different outputs to be tri
4. 1 PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON 50Hz mains frequency NOTES P64E 6E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Double key Keypad Panic enabled NOTES RELATED OPTIONS P62E 4E Shortcut Keypad Panic The Ness LCD keypad has two buttons labelled x P64E 7E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Keypad Fire Alarm NOTES RELATED OPTIONS P68E 6E Fire Siren sound P64E 8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Keypad Medical Alarm NOTES RELATED OPTIONS PROGRAMMING 50Hz MAINS FREQUENCY Selects either 50Hz or 60Hz mains power frequency operation Leave the factory default for use in Australia and New Zealand Users in North America should select 60Hz mains frequency Required for the accurate timing of dialler test reports if programmed It has no effect on local or other dialler operations PROGRAMMING SEQUENCE P64E 5E toggles the option ON and OFF P64E 5E OFF 60Hz mains frequency P64E 5E ON 50Hz mains frequency DOUBLE KEY KEYPAD PANIC This option allows the Keypad Panic alarm to be triggered by pressing both lt gt Panic buttons together NOTE cx User Code always triggers Keypad Panic PROGRAMMING SEQUENCE P64E GE toggles the option ON and OFF P64E 6E OFF No double key Keypad Panic P64E 6E ON Double key Keypad Panic enabled
5. Enter the new User Code Can be 3 to 6 digits long Enter the new User Code again The new code is displayed by the keypad lights followed by 3 beeps To exit Program Mode QUICK START 2 step by step Program light turns OFF KEY STROKES DESCRIPTION COMMENT OOOO Enter User Program Mode Program Light is ON 9 9 9 POOOOOOW Enter Installer Program Mode Program Light is FLASHING 9 9 9 1 Selects the option for User Code 1 ee bug QOOOCU Enter the new User Code Can be 3 to 6 digits long OOOOU Enter the new User Code again 8 Ce CE 4 At P86E turns ON option 4 Audible Monitoring enabled 9 POWE Selects the option for Telephone No 1 CI Upto 15 dits E Enter the telephone number Can be up to 15 digits lon g g QG To exit Program Mode Program light turns OFF See page 58 for further information on the operation of Audible Monitoring QUICK START 3 step by step KEY STROKES COOGEE Enter User Program Mode COMMENT Program Light is ON 0 00 0 0 0 0 Enter Installer Program Mode Program Light is FLASHING The existing code is di by th POO Selects the option for User Code 1 li Enter the new User Code Can be 3 to 6 digits long opoo Enter the new User Code again ot
6. Restoral on Disarm amp seal Restore on Disarm always Test Call Interval 84 168hrs Day Mode to STROBE OP Day Mode to SONALERT ode to SIREN 2sec Monitor Alarm Day 2sec Day Alarm Monitor Zones Entry Delay2 Radio Key Chirp amp Flash 50Hz Mains Frequency Double Key Keypad Panic Keypad Fire Alarm 1E Keypad Medical Alarm Supervised Radio Zones Supervision RESET output OFF 2E Supervision STROBE output OFF Supervision SONALERT OFF 4E Supervision SIREN output OFF 5E Supervision AUX1 output OFF 6E Supervision AUX2 output OFF Supervision SpeedUp x 6 OFF 8E Supervision SpeedUp x10 Supervision Time 3K3 Zone Resistors OFF 24 hours Reset OP Zones All zones Strobe Zones All zones Sonalert Zones All zones Siren Zones All zones Aux 1 Zones none Aux 2 Zones Entry Beeps none Ksw Monitor Disarm Ksw Arm Disarm Tamper siren lockout Duress to Reset OP Auto Exclude Zones Radio Panic Toggles AUX1 Radio Panic Pulses AUX1 Radio Arm unseal warning 24hr Zone Fire Siren 4th Button RadioKey AUX1 Quiet chirps on Arm Disarl ARM1 Pulse Output ARM2 Pulse Output Quiet Monitor Siren 6 Beeps on Arming Radio Key Monitor Arm Telephone No 1 Primary Auto KP display off De
7. DIRECT CONNECT Diagram 12V BATTERY Upload download on site a REMOTE ARMING Allows the remote Arming of the control panel using a standard DTMF telephone or mobile phone from anywhere in the world PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Remote Arming PROGRAMMING SEQUENCE P90E toggles the option ON and OFF PQOE OFF No Remote Arming P90E 3E ON Remote Arming enabled Remote Access must also be enabled RELATED OPTIONS P90E 1E Enable Upload Download See page 59 for details on Remote Operation by telephone NESS D8 V4 CONTROL PANEL INSTALLER MANUAL P9OE 4E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Remote Disarming NOTES PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Remote AUX control NOTES P9OE 6E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Remote Status Reporting NOTES 9 7E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Remote Event Reporting NOTES P9OE 8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Callback NOTES RELATED OPTIONS P90E 1E Enable Upload Download P81E Telephone Number 4 Callback PROGRAMMING REMOTE DISARMING Allows the remote Disarming of the control panel using a standard DTMF telephone or mobile phone from anywhere in the world PROGRAMMING SEQUEN
8. MISCELLANEOUS Only include mains fail in alarm memory when the previous event is not mains fail Fire Siren sound can be selected for 24hr zones Handy for Smoke Detectors Separate Icons added to keypad to distinguish 0 amp 9 on LCD keypad Day mode does not latch zone alarms The warnings are either for 2secs or while the Day zone is unsealed Zone Exclude with User Code Entry only accepts zones 1 8 that are in the AREAS that the User Code can arm In User Program Mode a Siren Test can be started by entering 77777777E 8 sevens and Dialler Test Report can be initiated by entering 66666666 8 sixes An option added which gives quiet siren chirps in Monitor mode instead of the full volume siren sound NESS D8 V4 CONTROL PANEL INSTALLER MANUAL t 4 E HOW TO REMOVE THE LID INSTALLING PCB STANDOFFS amp TAMPER BRACKET PACKING LIST 100 191 Ness D8 LED Control Panel 100 688 Ness D8 LCD Control Panel QTY DESCRIPTION 1 D8 mainboard 1 D8 housing 1 Ness LED keypad 100 192 or Ness LCD keypad 100 667 17VAC plug pack 12V 7Ah battery optional Dialler telephone lead User manual Installer manual 2 2K End Of Line resistors Lead assembly for Battery Lead assembly for Internal Tamper Tamper bracket Zone list label Housing cover screws Circuit board standoff NOMAS E iru Oey i due par E INSTALLATION PROCEDURES The location of the main panel
9. 46 Strobe Flash on 0 46 Forced Opening 47 Delay Closing 47 Manual Exclude 47 Auto Exclude Report see 47 Enable Test Calls eene 48 Mains Report Delay 48 Listen in to dialer sineira pti 48 Swinger Shutdown sese 49 Line Fault Monitor 49 Line Fault to AUX2 ieiet iiaii 49 Fiemote access oon 50 Direct Connect ssssesseeneeeeee 50 Remote access options 50 51 Required Rings tenete 52 FACTORY DEFAULTS Clear Radio Devices 53 Clear Memory nennen 53 Clear Panel 53 Clear User Codes eee 53 RADIO OPTIONS Radio Quick Start nienean a 54 Ness Radio Interface 54 Signal strength meter 54 Radio Devices Operation 55 Radio Supervision Defined 55 Radio
10. Enter new code Enter new code again l MOOD ddd COCOCOCOGD J VLVVG Jd TO DELETE A CODE To delete a User Code enter the MEMORY key in place of the code EXAMPLE To delete User Code 2 P12E MEMORY E ARM ONLY CODES User Codes 2 15 can be set as Arm Only Codes These codes can Arm but cannot Disarm the panel When programming a code enter ARM E in front of the code to enable the Arm Only option EXAMPLE To program User Code 2 to be 1234 and an Arm Only code P12E ARM E 1234E 1234E When the code is viewed the ARMED icon is displayed before the digits of the code CODE TABLE FACTORY DEFAULT ENABLE AS A RADIO CODE Keypad Code only OPTION No DESCRIPTION User Code 1 Master Code User Code 2 2E User Code 3 User Code 4 4E User Code 5 5E User Code 6 6E User Code 7 7E User Code 8 8E User Code 9 1E User Code 10 2E User Code 11 3E User Code 12 4E User Code 13 5E User Code 14 6E User Code 15 7E 000000 Installer Code Installer Code NESS D8 V4 CONTROL PANEL INSTALLER MANUAL PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT 20 seconds NOTES Programmable from 1 99 seconds P27E PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT 60 seconds NOTES Programmable from 10 990 seconds PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT 60 secon
11. HORN SPEAKER NOI110 Terminal block is supplied with Ness siren covers 5 be connected to the SIREN output E in parallel with the Horn Speaker s STROBE LIGHT TIP NOI300 100 171 Internal Horn Speaker has WHITE wires 100 172 Internal Siren has RED amp BLACK wires NESS D8 V4 CONTROL PANEL INSTALLER MANUAL INPUTS MONITORED ZONES The Ness D8 has 10 separate monitored inputs 8 x Fully programmable Zone inputs 2 x 24 hour Tamper input ZONE INPUTS Each zone input must be terminated with a 2K2 2200 ohm resistor as supplied All inputs must be sealed with an EOL resistor even if unused For wiring details of Keypads Keyswitches Panic Buttons and Warning devices see the wiring diagrams in the wiring section of this manual TAMP Tamper Input The TAMP input must also be sealed with a 2K2 end of line resistor This input is always a 24hr input AC INPUT TERMINALS These terminals are for the connection of the Ness plugpack The Ness D8 requires an AC transformer rating of 1 4 Amps 9 17 V AC minimum Ness Part No POW215 BATTERY These terminals are for the connection of a sealed lead acid rechargeable 12Volt battery Charge current is limited to 350mA The charge voltage is factory preset at 13 8 V and does not need changing Note A 12 Volt sealed lead acid rechargeable battery must be connected for correct panel operation Observe correct
12. Installer Remote by PC FACTORY DEFAULT 3E 8E ON Zones 3 8 are Instant NOTES INSTANT ZONES Instant Zones operate only in the Armed state When Armed at the expiry of exit time Instant Zones will activate assigned outputs immediately when triggered P40E Zone No E turns the options ON P40E Zone ON The zone is an Instant Zone To deselect the option select a different zone type in the DELAY GROUP When a zone is selected for this type it is automatically deselected from any other zone type in the DELAY GROUP PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1E ON Zone 1 has Entry Delay1 NOTES The keypad sonalert will beep during Entry Delay as a reminder to disarm the ENTRY DELAY1 ZONES Entry Delay1 zones operate only in the Armed state When Armed at the expiry of exit time these zones will activate the Entry Delay Timer1 P26E when they are triggered If the panel is not disarmed before the expiry of the Entry Delay Timer1 the alarm outputs will be activated P41E Zone No E turns the options ON P41E Zone No E ON The zone is an Entry Delay1 zone To deselect the option select a different zone type in the DELAY GROUP panel Entry beeps can be disabled by program option P60E 1E When a zone is selected for this type it is automatically deselected from any other zone type in the DELAY GROUP NESS D8 V4 CONTROL PANEL INSTALLER MANUAL d PROGRAM MODE LE
13. KEYPAD FIRE ALARM This option enables the Keypad Fire Alarm Pressing 3 and then activates the dialler and reports a Fire Alarm and triggers the siren The Fire Alarm siren sound is different to the normal alarm siren sound PROGRAMMING SEQUENCE P64E 7E toggles the option ON and OFF P64E 7E OFF No Keypad Fire Alarm P64E 7E ON Keypad Fire Alarm enabled KEYPAD MEDICAL ALARM This option enables the Keypad Medical Alarm Pressing 2 and then activates the dialler and reports a Medical Alarm PROGRAMMING SEQUENCE P64E 8E toggles the option ON and OFF P64E 8E OFF No Keypad Medical Alarm P64E 8E ON Keypad Medical Alarm enabled NESS D8 V4 CONTROL PANEL INSTALLER MANUAL ss rl PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT all OFF No Radio Supervision zones NOTES OE will turn all selections OFF MEMORY E will turn all selections ON RELATED OPTIONS P66E 1E 6E Radio Supervision Alerts P67E Radio Supervision Time 1 Programming Radio Devices P66E 1E 6E P67E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 24hrs NOTES A setting of less than 3 hours is not recommended The Supervision timer is reset on exit from Installer Program Mode on Arm or Disarm and on reception of the Supervision signal from the particular Radio PIR The Supervision signal from each Supervised Radio PIR is individually timed RELATED OPTION
14. NESS D8 V4 CONTROL PANEL INSTALLER MANUAL These options allow selective restoring of various factory defaults For example you can default clear all the User Codes without affecting any other programmed options PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT not applicable PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT not applicable P97E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT not applicable NOTES P98E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT User Code 1 123 All other codes blank NOTES This option DOES NOT clear the Installer Code PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 000000 NOTES PROGRAMMING DESCRIPTION DEFAULT NOTE Clear Radio Devices OPTION No not applicable Clear Memory not applicable Restore Factory Defaults not applicable Clear User Codes not applicable Program the Installer Code 000000 CLEAR RADIO DEVICES This option clears all Radio Device Codes Except Radio Keys assigned to Radio Codes Options PO1E PO8E are defaulted eg Radio PIRs assigned to zones 1 8 PROGRAMMING SEQUENCE P95E Clears Radio Device Codes CLEAR MEMORY Enter P96E when in Installer Program mode to clear all events in the Alarm memory display PROGRAMMING SEQUENCE P96E Clears Alarm Memory display CLEAR PANEL OPTIONS This option re
15. 2 Sec si Exit Tim m co m OPTION No DESCRIPTION 1E 2E 3E 4E 5E 6E 7 ossa a Ton Ton ON Factory default setting SYSTEM OPERATION SHORTCUTS Some keypad operations can be programmed to operate with or without a User Code PROGRAMMING SEQUENCE P62E 1E 6E toggles the options ON and OFF P62E 1E Memory Display shortcut P62E 2E Zone Exclude shortcut P62E 3E Monitor Mode shortcut P62E Keypad Panic shortcut P62E 5E Areal Arming shortcut P62E 6E Area2 Arming shortcut OPERATING EXAMPLES Arming without shortcut User Code Arming with shortcut E Keypad Panic without shortcut c gt User Code Keypad Panic with shortcut x SIREN BURST ON AUTO EXCLUDE This option allows the disabling of the 2 second siren burst at end of Exit Time which indicates a zone s has been Auto Excluded PROGRAMMING SEQUENCE P62E 7E toggles the option ON and OFF P62E 7E OFF Siren burst on Auto Exclude disabled P62E 7E ON Siren burst on Auto Exclude enabled EXIT TIME X10 This option multiplies the normal exit time by a factor of 10 PROGRAMMING SEQUENCE P62E 8E toggles the option ON and OFF P62E 8E OFF Exit Time is the time set by P28E P62E 8E ON Exit Time is multiplied by 10 EXAMPLE If P28E 22 seconds then if P62E 8E is ON the exit time is 22 x 10 220 seconds NESS D8 V4 CONTROL PANEL INSTALLER MANUAL PROGRAMMING xz A 5 iS g x
16. Callback for Up download none POOE Follow Me Telephone Number For Audible Dialling none OPTION No DESCRIPTION FACTORY DEFAULT P72bE Account Number 1 0000 P73E Account Number 2 0000 TELEPHONE NUMBERS 1 amp 2 The D8 can dial up to 2 phone numbers when an event is to be transmitted to a remote location Telephone numbers may be up to 15 digits long PROGRAMMING SEQUENCE P70E existing telephone number is displayed ENTER NEW TELEPHONE No E new telephone number is displayed EXAMPLE To program Telephone No 1 to be 03 1234 1234 P70E 0312341234E SPECIAL FUNCTIONS FOR ALL TELEPHONE NUMBERS TO CLEAR A TELEPHONE NUMBER To clear a telephone number enter the MEMORY key in place of the telephone number Example to clear a Telephone Number 1 press P70E MEMORY E SPECIAL CHARACTERS Applies to all telephone Numbers Pauses star or hash VF digits can be included in the dialling sequence by using the keys in the table below SPECIAL CHARACTER KEY ENTRY DISPLAYED ON LCD DISPLAY PAUSE 1 6sec ARM Key 12 Star MONITOR Key 10 Hash EXCLUDE Key 11 ACCOUNT NUMBER 1 amp 2 Account numbers for identifying the panel to the Central Station Area 1 Open Close reports will report on Account No 1 and Area 2 Open Close reports will report on Account No 2 Zone Alarms can be assigned to report on either Account Number as set by Option P79E All miscellaneous events eg Tampers Mains
17. FACTORY DEFAULT OFF ARM2 output toggles occur at the end of Exit Time NOTES This is useful as a Smoke Detector reset output with an optional external relay PROGRAMMING SEQUENCE P69E 2E toggles the option ON and OFF P69E 2E OFF ARM2 output toggles RELATED OPTIONS P60E 8E Delay ARM1 ARM2 outputs P69E 2E ON ARM2 output pulses QUIET MONITOR SIREN This option selects the Quiet Siren sound in Monitor Mode The Quiet Siren sound is a continuous beep beep beep sound rather than PROGRAM MODE LEVEL Installer Remote by PC the normal siren sound FACTORY DEFAULT OFF Normal siren sound in Monitor Mode NOTES PROGRAMMING SEQUENCE This does not affect the RESET output P69E toggles the option ON and OFF P69E 3E OFF Normal siren sound in Monitor Mode P69E 3E ON Quiet Siren sound in Monitor Mode NESS D8 V4 CONTROL PANEL INSTALLER MANUAL P69E 4E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Keypad gives 3 beeps on Arming NOTES The keypad beeps on Arm Disarm when Arming Disarming by keypad keyswitch or by Radio Key PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Radio Keys cannot Arm Monitor Mode NOTES PROGRAMMING 6 BEEPS ON ARMING Normally the keypad s onboard SONALERT gives 3 beeps when the D8 is Armed Turning this option ON will give 6 keypad beeps when Arming PROGRAMMING SEQUENCE P69E 4E toggles the option ON and OF
18. FACTORY DEFAULT all OFF No Day zones NOTES RELATED OPTIONS P63E 5E 8E Day zone output mapping P64E 2E 2 sec Day Mode alarm TYPICAL USES Instant alert when a delivery door is opened Doorway alert for a shop Turn ON option P63E 7E for keypad sonalert when a Day zone alarms PROGRAMMING MONITOR ZONES Monitor zones allow you to Arm selected zones while others are ignored Typically used for perimeter zones such as windows and doors while you are at home Example Upstairs zones are Disarmed while downstairs zones are Armed in Monitor mode PROGRAMMING SEQUENCE P51E Zone No E toggles the options ON and OFF P51E Zone No E OFF The zone is not a Monitor zone P51E Zone No E ON The zone is a Monitor zone 24hr ZONES 24hr Zones operate at all times regardless of the mode of panel operation i e Armed Disarmed or Monitor When alarmed these zones will activate assigned outputs immediately To reset those alarms a valid user code must be entered Selecting a zone as 24hr will override any other zone type setting such as Instant Delayed or Handover PROGRAMMING SEQUENCE P52E Zone No E toggles the options ON and OFF P52E Zone No E OFF The zone is not a 24hr zone P52E Zone No E ON The zone is a 24hr zone DAY ZONES Day Zones operate when the panel is fully disarmed i e when Area 1 Area 2 and Monitor are all off When alarmed these zones will activate the assigned outputs instantly
19. NOTES User Codes can be 3 to 6 digits in length User codes cannot start with 0 All codes must be unique to each other User Codes 2 15 can be programmed to be ARM ONLY codes When programming a code you must enter it twice for verification To clear an existing code re program that code with any number not an existing code beginning with 0 To clear all codes except the Installer Code enter P98E in Installer Program mode See Page 53 Codes are rejected if already used Some codes that are similar to existing codes may also be rejected Open Close reports are identified by user number when the control panel is base station monitored INSTALLER CODE NOTES All of the above notes also apply to the Installer Code The function of the Installer Code is to gain access to Installer Program Mode See Page 13 How To Enter Program Mode programming y 3 Page 57 PROGRAMMING RADIO PROGRAMMING See pages 56 57 USER CODES User codes are the 3 to 6 digit codes used to operate the panel by keypad User Codes 1 15 Used to arm disarm the panel These codes can also be programmed as Arm Only codes User Code 1 is also the Master Code which is used to access Client Program mode PROGRAMMING SEQUENCE P 11 25 E the existing code is displayed ENTER NEW CODE E ENTER NEW CODE AGAIN E the new code is displayed EXAMPLE To program the Master Code
20. assign all zones to Area 1 This is also the factory default OPERATION Arming and Disarming is carried out as normal from a single keypad or separate keypads installed in both areas or by Radio Key Area operation only applies to zones when they are in the armed state This means that Day 24hr and Monitor zones are independent of the area operations Note Area partitioning is in addition to Monitor Mode Any zone may be allocated to any area Areas will operate Zones 1 2 3 4 5 6 7 8 ON ON ON ON ON OPTION No P45E P46E DESCRIPTION Area 1 zones Area 2 zones ON Factory default setting ASSIGNING ZONES TO AREAS Assign or remove zones that will operate when Area 2 is armed PROGRAMMING SEQUENCE P45E Zone No E toggles the options ON and OFF for Area P45E Zone OFF The zone is not in Area1 P45E Zone ON The zone is in Areat P46E Zone toggles the options ON and OFF for Area2 P46E Zone No E OFF The zone is not in Area2 P46E Zone No E ON The zone is in Area2 EXAMPLE To program zones 1 4 for Area 1 and zones 1 5 8 for Area 2 In this example we have assigned zone 1 to both areas so it becomes a Common Zone P45E use the Zone No E sequence to turn ON only zones 1 4 P46E use the Zone No E sequence to turn ON zone 1 and zones 5 8 Example Zone 1 is assigned to both Areas so it is a Common Zone P45E AREA 1 zones SEE P46E AR
21. CONNECTION DIAGRAM 6 Wiring examples eem 7 Keypad 2 petet ite eec eue 10 OPERATION 11 HOW TO PROGRAM Quick start Programming 12 How to enter Program 13 Program mode levels 13 PROGRAMMING OPTIONS USER CODES eere eiie 14 id fb etel edges 15 Vibration Sensitivity eeenees 16 ZONE Assignment ecce 17 19 AREA PARTITIONING eren 20 21 Zone To Output Mapping 22 23 Various Options 24 25 Tamper Keypad Panic Output Mapping 26 System Operation 27 MONITOR MODE OUTPUT MAPPING 28 Day mode output mapping 28 Miscellaneous Options 29 SUPERVISED RADIO ZONES 31 31 Radio Supervision Alerts 32 33 Mis Options 1 rese 34 35 Misc Options 2 nid ens 36 37 DIALLER OPTIONS Telephone Numbers 1 amp 2 38 Account Number 1 a
22. Includes long life lithium battery Also available the 100 663PET radio Pet Aware model which detects humans but is immune to household pets NESS RADIO SMOKE DETECTOR Radio Smoke Detector using lonisation smoke detection technology With on board sounder A single battery powers the smoke detector and the transmitter Includes 9V lithium battery NESS D8 V4 CONTROL PANEL INSTALLER MANUAL PROGRAMMING OPTIONS SUMMARY OPTION PO1E PO8E DESCRIPTION Follow Me Tel No Enable Radio Devices 1 8 DEFAULT PAGE OPTION DESCRIPTION Monitor to RESET OP DEFAULT Monitor to STROBE OP 9 Enable Radio Keys 1 8 Enable Radio Keys 9 15 User Code 1 Master User Codes 2 15 Entry Delay Time 1 Entry Delay Time 2 Exit Delay Time Siren Reset Time Normal Zone Sens all zones P31E 38E Vibration Sens High Low DoubleTrigger Zones none none Instant Zones Zones 3 8 Entry Delay 1 Zones Zone 1 Handover Zones Zone 2 Entry Delay 2 Zones none Lockout Zones AREA 1 Zones All zones All zones AREA 2 Zones AREA1 Codes 1 8 none AREA1 Codes 9 15 AREA2 Codes 1 8 AREA2 Codes 9 15 Monitor Mode Zones none 24hr Zones none Day Zones none Monitor to SONALERT Monitor to SIREN Day Mode to RESET OP PAGE OPTION DESCRIPTION Restoral immediately DEFAULT PAGE Restoral after Siren Time
23. MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Swinger Shutdown enabled NOTES This prevents unnecessary multiple alarms reported to the Central station in cases for example where a door is swinging in the wind P89E 5E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Line Fault Monitor NOTES RELATED OPTIONS P89E 6E Line Fault to AUX2 P89E 6E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Line Fault output NOTES RELATED OPTIONS P89E 5E Line Fault Monitor PROGRAMMING SWINGER SHUTDOWN Limits the number of calls made by a zone alarm when Multiple Zone Alarms are enabled for that zone If enabled multiple reports are limited to three per zone PROGRAMMING SEQUENCE P89E 4E toggles the option ON and OFF P89E 4E OFF No Swinger Shutdown unlimited multiple reports P89E 4E ON Swinger Shutdown enabled maximum 3 reports per zone LINE FAULT MONITOR When this option is enabled the telephone line is regularly tested If the telephone line is not found the Line light will commence flashing PROGRAMMING SEQUENCE P89E 5E toggles the option ON and OFF P89E 5E OFF No Line Fault Monitor P89E 5E ON Line Fault Monitor enabled LINE FAULT TO AUX2 When this option is enabled a telephone line fault condition will turn ON the AUX2 output AUX2 will turn OFF when the telephone line is restored PROGRAMMING SEQUENCE P89E GE t
24. ON Test Calls enabled NOTES RELATED OPTIONS P83E Test Call Interval P84E Time before next Test call MAINS REPORT DELAY This option allows Mains Fail reports to be delayed by one hour if the mains P89E 2E power has been off continuously for that time Normally the Mains Fail report is sent immediately the power fails PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT PROGRAMMING SEQUENCE P89E 2E toggles the option ON and OFF ON Mains Fail report is delayed P89E 2E OFF Mains Fail reports immediately P89E 2E ON Mains Fail report is delayed by 1 hour NOTES LISTEN IN TO DIALLER This is a diagnostic feature for installers Listen In is turned on for a minimum of P89E 3E 4 minutes after exiting Program Mode During Listen In the dialler message and other telephone tones can be heard through the Siren output at low volume while the dialler is sending reports The 4 minute period is restarted whenever any key on the keypad is pressed PROGRAM MODE LEVEL Installer Remote by PC To turn Listen In off go back into Installer Program mode and toggle the option FACTORY DEFAULT OFF No Listen In NOTES For convenient and private Listen In temporarily connect a spare horn speaker to the Siren output OFF PROGRAMMING SEQUENCE P89E 3E toggles the option ON and OFF P89E 3E OFF No Listen In P89E 3E ON Listen In enabled NESS D8 V4 CONTROL PANEL INSTALLER MANUAL P89E 4E PROGRAM
25. PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF 4th button for AUX1 disabled NOTES RELATED OPTIONS P68E amp Radio Key Panic to AUX1 P68E 8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Quiet Chirps disabled NOTES RELATED OPTIONS P64E 4E Arm Disarm Chirps PROGRAMMING RADIO KEY ARMING UNSEALED ZONE WARNING Setting this option ON allows a 2 second SIREN warning if there is an unsealed zone in an Area Armed by a Radio Key PROGRAMMING SEQUENCE P68E 5E toggles the option ON and OFF P68E 5E OFF Radio Key arming siren warning disabled P68E 5E ON Radio Key arming siren warning enabled 24HR ZONE FIRE SIREN SOUND This option changes the siren sound when a 24hr zone is triggered PROGRAMMING SEQUENCE P68E GE toggles the option ON and OFF P68E 6E OFF Fire siren sound disabled P68E 6E ON Fire siren sound enabled 4th BUTTON RADIO KEY FOR AUX1 Ness 4 Button Radio Key only this option changes P68E 3E and 4E to work with the 4th Button of a 4 Button Radio Key instead of the PANIC button PROGRAMMING SEQUENCE P68E 7E toggles the option ON and OFF P68E 7E OFF 4th button Radio Key for AUX1 disabled P68E 7E ON 4th button Radio Key for AUX1 enabled QUIET CHIRPS ON ARM DISARM This quietens the siren chirps that are made whenever keyswitch or radio key Arming or Disarming is used Arm Disarm Chirps must be enabled at P64E 4E PROG
26. Polarity when connecting the battery Ness Part Number BAT210 12V 7Ah battery EARTH For maximum protection against damage caused by lightning strikes connect a good earth to this terminal Alternatively use the Earth lead from the plug pack PROG TAMP Program Link amp Internal Tamper Input The PROG TAMP link appears on the two pin J1 header The PROG TAMP link has two purposes 1 To enter Installer Program Mode on initial power up Power up with the PROG link OFF The PROG link or Box Tamper lead must be ON in operating mode 2 Box Tamper When used with the Internal Tamper Lead supplied PROG TAMP serves as the 24hr tamper input for the panel s internal tamper switch Replace the PROG Link with the Box Tamper Lead Connect the Internal Tamper Lead spade terminals directly to the terminals of the internal tamper switch supplied An end of line resistor is NOT required on this input When PROG TAMP is used for Internal Tamper powering up with the panel s cover open will enter Installer Program Mode NESS D8 V4 CONTROL PANEL INSTALLER MANUAL OUTPUT FUSING The 12V outputs Siren Reset and Strobe outputs are protected by Automatic Reset electronic fuses These outputs will automatically reset once the overload is removed BACKUP BATTERY A properly charged battery MUST be installed to ensure the Siren Strobe and Reset outputs operate correctly SIREN LOAD A maximum output of 2 0A continuous is avail
27. The outputs mapped to the Day Zone will turn on while the zone is unsealed Turn P64E 2E on to limit Day Zone alarms to 2 seconds PROGRAMMING SEQUENCE P53E Zone No E toggles the options ON and OFF P53E Zone No E OFF The zone is not a Day zone P53E Zone No E ON The zone is a Day zone NESS D8 V4 CONTROL PANEL INSTALLER MANUAL PROGRAMMING AREA PARTITIONING DEFINITION Area Partitioning allows the 8 zones to be split into two partitions Areal and Area2 The panel then effectively operates as two separate systems For example Office A and Office B operate as separate areas but the entrance foyer used by both offices is assigned to both areas meaning it will automatically Arm when both Areas have Armed The Common Area then automatically disarms when either Areal or Area2 Disarms sharing only the siren outputs and dialler USER CODE ASSIGNMENT A User Code assigned to an Area can Arm and Disarm only that Area User Codes assigned to both both Areas simultaneously COMMON AREA ZONES Zones assigned to both Areas are armed only when Area and Area2 are both armed This allows the Common Area zone s to be shared by both Areas P45E P46E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT No zones assigned to Area 2 NOTES For options P45E and P46E Zone No E toggles the selection ON and OFF Zones assigned to BOTH areas become Common zones f no Area operation is required
28. User Code 15 Installer Code Keypad Code only Installer Code 000000 NESS D8 V4 CONTROL PANEL INSTALLER MANUAL CENTRAL STATION MONITORING MONITORED PREMISES TELEPHONE LINE MONITORING STATION AUDIBLE MONITORING AT wt FIXED TELEPHONE MONITORED PREMISES TELEPHONE LINE MOBILE TELEPHONE AUDIBLE MONITORING REPORTING FORMAT TABLE DIGIT DIGIT A B ALARM Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Duress Keyswitch Tamper Panic Keypad Panic Radio Panic Medical alarm Fire alarm Exit from installer program mode External Tamper Internal Panel Tamper Keypad Tamper Radio Tamper Mains Fail Panel Battery Fail RADIO Battery Fail 8 G9 G9 G9 IN CO NN OD A IN 1D OB ow OD oy Bo pm RADIO Supervision Fail CENTRAL STATION MONITORING The D8 control panel has an on board digital dialler which can send detailed alarm messages to a Central Monitoring Station The digital messages can include information about the zone s which caused the alarm tamper alarms low battery or mains failure reports and it can also by user number identify the users who Arm and
29. and PANIC buttons in a slim waterproof remote control Ness radio products require a Ness Radio Interface 100 200 to be fitted to the control panel NESS RADIO PENDANT Fully waterproof pendant style transmitter can be used as a portable wireless Panic button Supplied with a neckchain as well as wristwatch straps Ideal for use as a medical alarm for the elderly or infirm Central Station Monitoring is especially recommended when used for medical alarm purposes Includes long life lithium battery NESS RADIO REED SWITCH Ness Radio Reed Switch for wireless door and window protection Includes long life lithium battery NESS RADIO KEYPAD A unique fully portable radio keypad The Ness Radio Keypad provides totally wireless Arming Disarming of the Ness D8 D16 amp D24 control panels Also operates Monitor mode and Panic when used with the Ness D16 D24 panels The Ness radio Keypad is suitable for use as a portable keypad or for adding an extra keypad in areas where it is not possible to install wires NESS RADIO KEY 3 BUTTON Fully waterproof ultra slim 3 button Radio Key for remote control of the control panel With separate buttons for ON Arm OFF Disarm and PANIC functions Includes long life lithium battery NESS RADIO PIR Ness Radio PIR Passive Infrared motion detector for wireless motion detection Can be used in combination with Ness hardwired detectors in areas where it is not possible to install wires
30. applied with a soft object e g by hand does not cause an alarm whereas a rapid series of blows using a metal object such as a screw driver blade will cause an alarm Ness NESSENSOR Vibration sensor Part No VIB100 In addition to zone sensitivity adjustment the overall sensitivity of the Nesssensor can be adjusted by rotating the body of the Nesssensor within its bracket The bracket must always be mounted horizontally and the arrow must point up for any required setting PROGRAMMING VIBRATION SENSITIVITY Each zone has individually adjustable sensitivity for connection of Nessensor Vibration Sensors Zone sensitivity is adjusted by toggling zones ON in options to P38E P30E Normal Sensitivity vibration analyser disabled This is used for normal alarm devices Zone response time 200ms P31 38E are the options for the 8 levels of vibration sensitivities P31E is the most sensitive setting PROGRAMMING SEQUENCE P 30 38 E zones are displayed Zone No E EXAMPLE To program zones 2 and 3 to be Medium Sensitivity P34E 2E 3E the keypad display will show zone lights 2 amp 3 to be ON 123 45 67 8 Factory Default Setting for P30E All zones selected ON Normal Example P34E Zones 2 amp 3 are Medium sensitivity sensitivity VIBRATION SENSITIVITY Zones OPTION No SENSITIVITY 1 2 3 4 5 6 7 8 ON Factory default setting
31. code used is included in the report Keyswitch Arming and Shortcut Arming are identified as User 15 PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No AREA1 Open Close reports NOTES PROGRAMMING SEQUENCE P88E 1E toggles the option ON and OFF P88E 1E OFF No AREA1 Open Close reports P88E 1E ON AREA1 Open Close reports enabled AREA2 OPEN CLOSE REPORTS Enables or disables sending of AREA2 Open Close reports P88E 2E PROGRAMMING SEQUENCE P88E 2E toggles the option ON and OFF PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No AREA2 Open Close P88E 2E OFF No AREA2 Open Close reports P88E 2E ON AREA2 Open Close reports enabled NOTES SIREN CHIRP ON KISS OFF Selects a 2 Second Siren burst on a successful Closing report This is used to P88E 3E give audible indication that the dialler has successfully sent the Arming report PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Siren Chirp on kiss off PBOGHAMMING SEBMENGE P88E 3E toggles the option ON and OFF P88E 3E OFF No Siren Chirp on kiss off P88E 3E ON Siren Chirp on kiss off enabled NOTES RELATED OPTIONS P88E 4E Flash Strobe on kiss off STROBE FLASH ON KISS OFF Selects a 2 Second Strobe on a successful Closing report This is used to give P88E 4E visual indication that the dialler has successfully sent the Arming report PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAUL
32. has not been removed from radio range and is in working order Non SUPERVISION Radio PIRs can also be programmed and used with the D8 SUPERVISION TIMERS A non SUPERVISION enabled Radio PIR will transmit signals to the D8 only when it has detected an event Obviously there is no guaranteed signal period In either case when the allowed time limit is exceeded then a WARNING is first given if programmed by P66E 3E and then after 1 minute the programmed RADIO SUPERVISION ALERTS are generated by the D8 NOTE Manually Excluding a Supervised Zone will also disable Radio Supervision for that zone NESS D8 V4 CONTROL PANEL INSTALLER MANUAL PROGRAMMING 5 8 S amp B8 I gt Pease oe E 2 X X ke O A T c5 BC E S 9 SSS 2 2 2 2 2 2 g gg SQ STS oS OS 43 00306030 EI 5 OPTION No DESCRIPTION 1E 2E 3E 4E 5E 6E 7 P66E Radio Supervision Alerts 0 ON Factory default setting RADIO SUPERVISION ALERTS RESET OUTPUT Setting this option turns the Reset output ON when a SUPERVISED RADIO alert occurs The Reset output will remain ON for the duration of the ALARM TIME Set by Option P29E PROGRAMMING SEQUENCE PROGRAM MODE LEVEL P66E 1E toggles the option ON and OFF Installer Remote by PC FACTORY DEFAULT OFF Supervision Reset output disabled NOTES RELATED OPTIONS P65E Supervised Radio Zones P66E 1E OFF Supervision Reset output disabl
33. panel security remote operations can only be activated after entering a valid user code To operate the D8 by telephone you need a DTMF capable telephone a valid User Code and you must know the Telephone number of the line to which the D8 is connected NOTES f the D8 does not receive commands for periods longer than 10 seconds it will assume that the call is finished and it will hang up If an alarm occurs which requires the D8 to dial out while attempting remote control the D8 will treat the alarm as a priority give a constant tone as a warning and then hang up When all remote control commands are finished press x st to force the D8 to hang up NESS D8 V4 CONTROL PANEL INSTALLER MANUAL SEQUENCE OF OPERATION 1 Phone the D8 telephone number and listen for the required number of rings ring ring ring ring and then hang up 2 Wait 10 seconds and then call the number again within 50 seconds 3 The D8 will answer the second call immediately sound a beep for 2 seconds then after a pause it will sound a lower frequency tone The D8 is now ready to receive telephone commands 4 Press the 9 button on the telephone This tells the D8 that telephone commands will follow The D8 will respond with either 3 beeps if all OK One long beep means try again 5 Now enter a valid User Code that is normally used for Arming or Disarming the D8 followed by the button The D8 will respon
34. zone is an Entry Delay2 zone To deselect the option select a different zone type in the DELAY GROUP RESET LOCKOUT ZONES All 8 zones and tamper input can be programmed to Lockout i e cause the RESET OUTPUT to sound only once whilst the panel is armed The RESET OUTPUT is then locked out for that alarmed zone until entering a valid code has reset the panel PROGRAMMING SEQUENCE P44E Zone toggles the options ON and OFF Zone OFF The zone is not a Lockout zone Zone No E ON The zone is a Lockout zone AREA PARTITIONING See page 20 ASSIGNING USER CODES TO AREAS See page 21 NESS D8 V4 CONTROL PANEL INSTALLER MANUAL d PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT all OFF No Monitor zones NOTES RELATED OPTIONS P63E Monitor Mode output mapping P64E 1E 2 second Monitor Mode alarm P64E 3E Monitor zones have Entry Delay2 PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT all OFF No 24hr zones NOTES The Tamper input is always a 24hr zone For silent 24hr zones simply deselect the zone s from options P54E P57E Reset Strobe Sonalert amp Siren To change a 24hr zone to any other zone type the zone must also be re assigned to an AREA P45E or P46E 24hr zones are independent of Area operation All other zone types must be assigned to at least one Area to become active PROGRAM MODE LEVEL Installer Remote by PC
35. 00 663 and Radio Reed Switches 100 662 send Supervision signals SUPERVISION RELATED OPTIONS P65E Supervised Radio Zones P66E 1E 8E Radio Supervision Alerts P67E Radio Supervision Time P75E 12E Radio Supervision Fail Report RELATED OPTIONS PO9E P10E Programming Radio Keys RADIO DEVICES OPTION TABLE NESS RADIO RADIO DEVICE PROGRAMMING Each of the 8 zones of the D8 can be a radio zone Once programmed zones can accept both Radio Devices and normal zone inputs simultaneously The optional 100 200 Ness Radio Interface is required for Radio Devices to operate A Radio Device is any type of Ness transmitter including Radio PIR Radio Reed Switches Radio Smoke Detector PROGRAMMING RADIO DEVICES Up to 8 Radio Devices can be assigned one per zone PROGRAMMING SEQUENCE NO RESTORALS Suitable for 100 663 Radio PIR 100 665 Radio Pendant 100 203 Radio Smoke Detector Select a zone using PO1E PO8E The ARMED light will be ON if a Radio Device is already programmed to the zone Press OE to delete Q Press 1E The READY light will turn ON to indicate that the zone is ready to accept the Radio Device Trigger the Radio Device A If the Radio Device is accepted the READY light will turn off the ARMED light will turn on and 3 beeps will sound B If the READY light stays on and a warning beep sounds the Radio Device is already assigned to another zone and must be cleared from that zone first EXAMPL
36. 8 to AREA P48E 1E 7E toggles the options ON and OFF Assigns User Codes 9 15 to AREA1 P49E 1E 8E toggles the options ON and OFF Assigns User Codes 1 8 to AREA2 P50E 1E 7E toggles the options ON and OFF Assigns User Codes 9 15 to AREA2 EXAMPLE To assign User Codes 1 8 to AREA1 and User Codes 9 15 to AREA2 P47E turn ON lights 1 8 P48E turn OFF lights 1 7 P49E turn OFF lights 1 8 P50E turn ON lights 1 7 User Codes gt 1 2 34 5 6 7 8 9 10 1112 13 14 15 123 4567 8 EXAMPLE AREA 1 User codes 1 8 are assigned to AREA 1 PROGRAM PROGRAM User Codes 1 8 P48E User Codes 9 15 UserCodes gt 1 2 34 56 7 8 9 10 11 12 13 14 15 AREA 2 EXAMPLE User codes 9 15 are assigned to AREA 2 PROGRAM PROGRAM P49E User Codes 1 8 P50E User Codes 9 15 NESS D8 V4 CONTROL PANEL INSTALLER MANUAL NOTE Zone To Output Mapping applies to zones when the panel is in the Armed or 24hr state For MONITOR and DAY mode Output Mapping see Option P63E 1E 8E page 28 P51 P53E page 19 PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT all ON All zones trigger Reset output NOTES OE will turn all selections OFF MEMORY E will turn all selections ON PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT all ON All zones trigger Strobe output NOTES OE will turn all selections OFF MEMORY E will turn all selections ON PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT
37. ANEZSZ D 8 NESS D8 CONTROL PANEL AND DIALLER INSTALLATION amp PROGRAMMING MANUAL NESS D8 CONTROL PANEL V4 INSTALLATION MANUAL REVISION 1 A 12 00 INC GST VERSIONS COMMENCING NOVEMBER 2001 Australia s largest designer and manufacturer of high quality security products 55 NESS SECURITY PRODUCTS Australian Communications Authority TELECOMMUNICATIONS COMPLIANCE Quality Endorsed Company 1509001 LIC No QEC2074 NSW Head Office only INEZ Ness Security Products Pty Ltd s 2 2 E El E 6 WWW NESS COM AU HEAD OFFICE Ness Security Products Pty Ltd ACN 069 984 372 4 167 Prospect Hwy Seven Hills NSW 2147 Australia Ph 61 2 8825 9222 Fax 61 2 9674 2520 ness ness com au SYDNEY 02 8825 9222 MELBOURNE 03 9878 1022 BRISBANE 07 3343 7744 ADELAIDE Aquavia Controls 08 8277 7255 PERTH 08 0328 2511 NEW ZEALAND NFS NZ 64 9 573 0401 D8 V4 INSTALLER MANUAL Revision 1 November 2001 Document Part Number 890 265 For product 100 191 D8 LED Control Panel V4 100 688 D8 LCD Control Panel V4 2001 Ness Security Products Pty Ltd ACN 069 984 372 D8 V4 installer rev1 pmo221001 Specifications may change without notice CONTENTS Introduction uci rehenes 4 Features etant deren tedetitiitees 4 Specifications n te ee pice 4 Packing list ui sancte 5 Installation 5
38. CE RELATED OPTIONS P82E 1E 4E toggles the option ON and OFF P76E Report zone restorals P82E 1E Send Restoral immediately P82E 2E Send Restoral after siren time P82E 3E Send Restoral on Disarm amp seal P82E 4E Send Restoral on Disarm always NESS D8 V4 CONTROL PANEL INSTALLER MANUAL ss rl PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 84 168hrs 7 days NOTES Enter a value from 1 to 99 RELATED OPTIONS P89E 1E Enable Test Calls P84E Time Before Next Test Call P84E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 6 12hrs NOTES Enter a value from 1 to 99 f Test Calls are to start immediately then the value is set to 0 The Time Before Next Test Call is constantly updated When viewed the current value will be displayed not the initially entered value RELATED OPTIONS P89E 1E Enable Test Calls P83E Test Call interval PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1E ON Auto Dialling Method NOTES Only one option is allowed to be ON PROGRAMMING OPTION No DESCRIPTION DEFAULT NOTE P83E Test Call Interval 84 x2 168hrs 7 days P84E Time Before Next Test Call 6 x2 12hrs TEST CALL INTERVAL Test calls to the Central Station can be sent at intervals between 2 and 198 hours in 2 hour increments Programmable from 2 to 198 Hours Enter a value between 1 and 99 This is automatically multiplied by 2
39. CE PSOE toggles the option ON and OFF P9OE OFF No Remote Disarming P90E 4E ON Remote Disarming enabled REMOTE AUX CONTROL Enables the remote turn ON OFF of the AUX1 amp AUX2 outputs using a standard DTMF telephone or mobile phone from anywhere in the world PROGRAMMING SEQUENCE PSOE toggles the option ON and OFF P90E 5E OFF No Remote AUX control P90E 5E ON Remote AUX control enabled REMOTE STATUS REPORTING Enables Remote Status Reporting PROGRAMMING SEQUENCE PSOE 6E toggles the option ON and OFF P9OE OFF No Remote Status Reporting P90E 6E ON Remote Status Reporting enabled REMOTE EVENT REPORTING Enables Remote Event Reporting PROGRAMMING SEQUENCE P90E 7E toggles the option ON and OFF P9OE 7E OFF No Remote Status Reporting P90E 7E ON Remote Status Reporting enabled CALLBACK MODE Enables two methods of connecting by computer for remote upload download NO CALLBACK Allows remote access by computer as long as the panel s Account Number P72E is known The panel answers on the 2nd incoming call WITH CALLBACK The panel will answer the 2nd call verify the caller hang up and then make the Callback using Telephone Number 4 PROGRAMMING SEQUENCE PSOE 8E toggles the option ON and OFF 9 8E OFF No Callback P90E 8E ON Callback Mode enabled NESS D8 V4 CONTROL PANEL INSTALLER MANUAL PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1 N
40. Device Programming 56 Radio Key Programming 57 REMOTE OPERATION Audible Monitoring Operation 58 Remote Operation by Telephone 59 Ness ACC6eSSOTIOS eidem 60 Wireless Products ui bo eei e ater 61 PROGRAMMING OPTIONS SUMMARY 62 Installation Record 63 FEATURES 8 Fully programmable zones Any combination of hardwire or radio zones Full radio supervision Contact ID Dialler Format Ultra Modern and Impact resistant Housing Ness Audible Dialler Format Follow Me Audible Dialler Option Separate 24 Hour Tamper input Single or Double Trigger Zones Remote LED or LCD Keypads Max 3 Fully programmable via the system Keypad Eliminates the need for expensive programmers or Proms Inbuilt Vibration Sensor Analyser All programming data is perma nently stored in a non volatile EEprom memory Windows based Up Down load Software allows remote program ming and event status True Dynamic Battery Test every time the Panel is armed disarmed and every hour Area Partitionable 2 Areas Any Zone can be programmed to any area as well as common areas Comes complete with an AC plug pack and supports a 12V 7Ah battery to maintain systems security under all power supply conditions Monitor Mode Home Mode Out
41. Disarm the system Central Station Monitoring is highly recommended and is the most effective method of monitoring your D8 alarm system Installers are welcome to contact Ness for further information about monitoring AUDIBLE MONITORING While Central Station Monitoring is recommended the D8 can also send audible alarm reports to any DTMF capable telephone The types of alarms sent are listed in the Reporting Format Table The basic audible message takes the form of N pause A pause B pause N The first digit of the Account Number P72E can be the digits 1 9 If P72E starts with N is not sent A First digit of the Alarm identifier See Reporting Format Table B Second digit of the Alarm identifier See Reporting Format Table MESSAGE EXAMPLE AUDIBLE PULSE FORMAT P86E 4E If the Account Number is 1234 and zone 5 alarm is reported beep pause beep beep beep beep beep 1 Beep 5 Beeps zone 5 1st digit of the account number REPORTING SEQUENCE When triggered by an alarm event the D8 will call the Primary Telephone Number or the Follow Me Telephone Number if programmed and at the end of the dialling of the last digit it will wait for 5 seconds and then commence the audible message the audible message will continue to repeat for 45 seconds or until it is kissed off by a DTMF tone If there is more than one alarm message to transmit then after it has received the Kiss off Acknowledge tone it
42. E is allowed to be ON P86E 5E ON Contact ID Audible DTMF format enabled P86E 6E CONTACT ID AUDIBLE PULSE FORMAT PROGRAM MODE LEVEL For simultaneous Central Station and Audible Monitoring Installer Remote by PC The alarm message will be sent to the Central Station on the Primary telephone FACTORY DEFAULT number and then in audible PULSE format to the Follow Me telephone number OFF NOTES PROGRAMMING SEQUENCE Only one option in the range P86E GE turns the option ON P86E 1 6 is allowed to be P86E 6E ON Contact ID Audible PULSE format enabled CONTACT ID CODES TABLE ACCOUNT The D8 reports alarms to the ALARM EVENT NUMBER XYZ GG CCC SUFFIX Central Station using Contact ID dialler format Zones 1 8 Alarm AAAA Q 130 GG 001 008 k The message format is fixed as shown in ee Contact ID Codes Duress AAAA Q 121 01 030 K Table Keyswitch Panic AAAA 120 01 031 k Keypad Panic AAAA 120 01 032 k Radio Key Panic AAAA 120 01 by User k The message takes the form of Medical Alarm AAAA Q 100 01 033 k AAAA Account Number P72E Fire AADA SR VU 09d k Q Event qualifier Exit Install mode AAAA Q 306 01 035 k External Tamper AAAA Q 137 01 040 k XYZ Alarm type Internal Tamper AAAA Q 187 O1 041 k GG Group or Area designation Keypad Tamper AAAA Q 137 01 042 k CCC Alarm number Radio Sensor Tamper AAAA Q 383 01 by Devi
43. E P64E 2E toggles the option ON and OFF P64E 2E OFF Day Mode outputs are ON while the zone is unsealed P64E 2E ON Day Mode outputs are ON for 2 seconds only RELATED OPTIONS P53E Assign Day zones P63E 5E 8E Day Mode output mapping MONITOR ZONES ENTRY DELAY2 Monitor zones can either have the delay types set by options 40 or they can all be assigned to have Entry Delay 2 This allows all Monitor zones to be programmed with the same entry delay time PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Monitor zones all have Entry Delay2 PROGRAMMING SEQUENCE P64E toggles the option ON and OFF P64E 3E OFF Monitor zones behave as programmed by P40E P43E P64E 3E ON Monitor zones all have Entry Delay2 NOTES RELATED OPTIONS P27E Entry Delay Time 2 P51E Assign Monitor zones P63E 1E 4E Monitor Mode output mapping ARM DISARM CHIRPS If this option is selected the Siren and Strobe Outputs will Chirp when the P64E 4E PROGRAM MODE LEVEL Installer Remote by PC panel is Armed and Disarmed with the Keyswitch or Radio Keys FACTORY DEFAULT The panel will make 1 Chirp on Arming and 3 Chirps on Disarming OFF No chirps NOTES PROGRAMMING SEQUENCE RELATED OPTIONS P64E 4E toggles the option ON and OFF P68E 8E Quiet Chirps P64E 4E OFF No Arm Disarm chirps P64E 4E ON Siren amp Strobe outputs will chirp on arm disarm NESS D8 V4 CONTROL PANEL INSTALLER MANUAL p
44. E To program a Radio PIR on zone 1 PO1E 1E Trigger the Radio PIR or simply connect the battery PROGRAMMING SEQUENCE WITH RESTORALS Suitable for 100 662 Radio Reed Switch Alarm the reed switch ie move the magnet away from the switch Leave the reed switch in the alarm condition and wait until radio transmission has stopped Select a zone using PO1E PO8E The ARMED light will be ON if a Radio Device is already programmed to the zone Press OE to delete Press 1E The READY light will turn ON to indicate that the zone is ready to accept the Radio Device Restore the reed switch place the magnet next to the switch A If the Radio Device is accepted the READY light will turn off the ARMED light will turn on and 3 beeps will sound B The MEMORY light will turn on to indicate that this device sends Restorals C If the READY light stays on and a warning beep sounds the Radio Device is already assigned to another zone and must be cleared from that zone first EXAMPLE To program a Radio Reed Switch with Restorals on zone 2 Alarm the reed switch PO2E 1E Restore the reed switch DELETING A RADIO DEVICE Use to POSE to select the zone Press OE to clear the device 3 beeps will sound TIP To prevent conflicting radio signals when programming Radio Devices disable each device once you have finished programming it Remove the battery or open the RADIO link Remember to enable all the devices when progr
45. EA 2 zones PROGRAM NESS D8 V4 CONTROL PANEL INSTALLER MANUAL ___ PROGRAMMING QN w amp 2 2 amp Qu m 222253888 2228888 96565998966 6 965989686 6 o o o O9 GO 35952555355 SS SoS OPTION No DESCRIPTION OPTION No DESCRIPTION PATE Codes 1 8 AREA1 ON ON ON ON ON ON ON ON P48E Codes9 15to AREA1 ON ON ON ON ON ON ON P49E Codes 1 8 to AREA2 ON P50E Codes 9 15 to AREA2 P47E P48E DESCRIPTION Area 1 User Codes PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All User Codes assigned to Area 1 P49E P50E DESCRIPTION Area 2 User Codes PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT User Code 1 Master Code assigned to Area 2 NOTES User Codes can be assigned to either a single Area or to both Areas f a User Code is assigned to NO Areas the code is effectively disabled and will not operate the panel To make a User Code arm or disarm just one Area assign that code only to the required Area Assigning User Codes to Areas has no effect unless zones are also assigned to Areas For this option Zone No E toggles the selection ON and OFF ON Factory default setting ASSIGNING USER CODES TO AREAS Assign or remove User Codes to Areas PROGRAMMING SEQUENCE P47E 1E 8E toggles the options ON and OFF Assigns User Codes 1
46. ER SECURITY ALARM PANEL NESS D8 Monitoring Company ALARM CONTROL PANEL Telephone Lr ZONE ASSIGNMENT eo sg P26E ENTRY DELAY TIME 1 Seconds KE E LL amp P27E ENTRY DELAY TIME 2 Seconds aa m n z aa 4 E a O E uuo gt P28E EXIT DELAY TIME Seconds ECOG E EE FZ Tne 2 z zZz x HE OE oo P29E SIREN RESET TIME Minutes I lt lt gt a tn HH T e N o T N i N i i i i i N amp a a a na ZONES DEVICE Sme o DESCRIPTION Entrance bedroomt etc 1 2 3 4 5 6 7 8 AREA 1 AREA 2 RADIO KEY CODE OPTION No CODE HOLDER CODE Y N User Code 1 8 P11E Keypad Code only User Code 2 P12E User Code 3 P13E User Code 4 P14E User Code 5 P15E User Code 6 P16E User Code 7 P17E User Code 8 P18E User Code 9 P19E User Code 10 P20E User Code 11 P21E User Code 12 P22E User Code 13 P23E User Code 14 P24E User Code 15 P25E 2001 Ness Security Products NESS D8 V4 CONTROL PANEL INSTALLER MANUAL blank
47. ESS D8 V4 CONTROL PANEL INSTALLER MANUAL PRO GRAMMING 2 S E go lt S Ni Qe es 1E 2E 3E 4E 5E 6E 7E 8E OPTION No DESCRIPTION Pest Miscelaneos opos ON Factory default setting UPERVISION TIME page 31 P67E S P68E 2E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No 3K3 zone resistors NOTES e The 3K3 zone resistor option is useful when installing the panel in a site pre wired with 3K3 resistors e If Zone 8 is converted to a keyswitch input then a 2K2 monitoring resistor is always used P68E 3E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Radio Key Panic to AUX1 disabled NOTES This option is useful for triggering 3K3 ZONE RESISTORS Setting this option ON changes the Zone 1 to Zone 8 and External Tamper monitoring resistor from 2K2 to 3K3 PROGRAMMING SEQUENCE P68E 2E toggles the option ON and OFF P68E 2E OFF 3K3 zone resistors disabled P68E 2E ON 3K3 zone resistors enabled RADIO KEY PANIC TOGGLES AUX1 Setting this option ON changes the action of the Radio Key Panic button so that the AUX1 output is toggled ON and OFF Each press on Panic toggles the state of AUX1 between ON and OFF If a 4 Button Key is used then this option can be used with the 4th key instead of the Panic key using P68E 7E This then allows the Panic key to still activate Panic reports PROGRAMMING SEQUENCE P68E toggles t
48. F P69E 4E OFF Keypad gives 3 beeps on Arming P69E 4E ON Keypad gives 6 beeps on Arming RADIO KEY MONITOR ARMING Setting this option on allows a double press of a Radio Key OFF button to ARM the D8 in MONITOR mode Requires two presses of the Radio Key OFF button within 4 seconds PROGRAMMING SEQUENCE P69E toggles the option ON and OFF P69E 5E OFF Radio Key Monitor Mode Arming disabled P69E 5E ON Radio Key Monitor Mode Arming enabled NESS D8 V4 CONTROL PANEL INSTALLER MANUAL P70E P71E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT No telephone numbers NOTES e If telephone number 2 is disabled all Calls are made on telephone number 1 and the setting of P87E 1E has no effect e f telephone number is disabled all test calls are made on telephone number 1 amp 2 Any keypress will stop the telephone number display sequence RELATED OPTIONS P87E 1E Alternate Primary Secondary telephone numbers P86E 1E Disable dialler still allows remote up download if programmed P72E P73E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT P72E Account No 1 0000 P73E Account No 2 0000 NOTES RELATED OPTIONS P79E Account No 2 zones PROGRAMMING OPTION No DESCRIPTION FACTORY DEFAULT P70E Telephone Number 1 Primary none P71E Telephone Number 2 Secondary none P80E Telephone Number 3 Test Calls none P81E Telephone Number 4
49. FACTORY DEFAULT 5E 8E ON Panic alarm triggers all PROGRAMMING SEQUENCE P61E 5E 8E toggles the options ON and OFF P61E 5E Keypad Panic Alarm to Reset output P61E 6E Keypad Panic Alarm to Strobe output P61E 7E Keypad Panic Alarm to Keypad Sonalert output outputs P61E 8E Keypad Panic Alarm to Siren output NOTES A Keypad Panic Alarm can be caused by the PANIC keys on the keypad E or together depending on Option P64EGE NESS D8 V4 CONTROL PANEL INSTALLER MANUAL PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1E ON Memory Display shortcut enabled 2E ON Zone Exclude shortcut enabled 3E ON Monitor Mode shortcut enabled 4E OFF Keypad Panic disabled 5E ON Areal Arming shortcut enabled 6E OFF Area2 Arming shortcut disabled NOTES A Tamper Alarm can be caused by the TAMP input or the J1 link Allocate a User Code to Area2 before programming Area2 shortcut arming If Area 2 is shortcut armed then it will always remain armed This will bar entry into program mode until Area 2 is disarmed P62E 7E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Siren burst on Auto Exclude enabled NOTES RELATED OPTIONS P60E 6E Auto Exclude zones P62E 8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Exit Time x10 disabled NOTES RELATED OPTIONS P28E Exit Time PROGRAMMING 9 Ing uto Exclude 7622 Armi e x19 A A en
50. Fail will report on Account No 1 PROGRAMMING SEQUENCE P72E or P73E existing account number is displayed ENTER NEW ACCOUNT No E new account number is displayed EXAMPLE To program Account No 1 to be 1239 P72E1239E NESS D8 V4 CONTROL PANEL INSTALLER MANUAL P80E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT No telephone numbers NOTES RELATED OPTIONS P89E 1E Enable test calls P83E Test call interval P84E Test call start delay PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT No telephone numbers NOTES RELATED OPTIONS P9OE 8E Enable Callback PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT No telephone numbers NOTES f the Follow Me telephone number is disabled all audible format calls are made on telephone numbers 1 amp 2 RELATED OPTIONS P86E 3E Audible DTMF format P86E 4E Audible Pulse format P86E 5E Contact ID Audible DTMF P86E 6E Contact ID Audible Pulse PROGRAMMING TELEPHONE NUMBER 3 TEST CALLS Phone Number 3 is used to send Test Calls If it is not programmed then Test Calls are sent using Telephone No 1 amp 2 PROGRAMMING SEQUENCE P80E existing telephone number is displayed ENTER NEW TELEPHONE No E new telephone number is displayed EXAMPLE To program Telephone No 3 to be 03 2468 1234 P70E0324681234E TELEPHONE NUMBER 4 CALLBACK Phone Number 4 is used for upload download Prevents unau
51. G TAMPER ALARM LOCKOUT This option programs the Tamper input to Lockout i e cause the Siren amp Reset outputs to sound only once whilst the panel is armed PROGRAMMING SEQUENCE P60E 4E toggles the option ON and OFF P60E 4E OFF Tamper Reset Lockout disabled P60E 4E ON Tamper Reset Lockout enabled DURESS TO RESET OUTPUT Keypad Duress is normally a silent alarm This option makes the Duress alarm trigger the Reset output PROGRAMMING SEQUENCE P60E 5E toggles the option ON and OFF P6OE 5E OFF No Reset output on Duress alarm P6OE 5E ON Duress alarm triggers Reset output AUTO EXCLUDE ZONES If a zone is unsealed at the end of Exit Time the panel can either Exclude ignore that zone or immediately alarm The panel will give a 2 second Siren burst at the end of Exit Time to indicate that the panel is armed with a zone s Auto Excluded The 2 sec Siren burst can be disabled by option P62E 7E PROGRAMMING SEQUENCE P60E GE toggles the option ON and OFF P60E 6E OFF Auto Exclude disabled instant alarm if unsealed at end of Exit Time P60E 6E ON Auto Exclude enabled zone is excluded if unsealed at end of Exit Time DISABLE THE DISPLAY The LED indicators on the keypad can be programmed to blank after 4 minutes of no keypad use Any action that causes a beep will restore the display Use the button preferably PROGRAMMING SEQUENCE P60E 7E toggles the option ON and OFF P6OE 7E OFF Display is al
52. NG SEQUENCE P60E 2E or toggles the option ON OFF P60E 2E amp 3E OFF No keyswitch operation Zone 8 is a normal alarm input P60E 2E ON Keyswitch cycles between Monitor and Disarm P60E ON Keyswitch cycles between Arm and Disarm in parallel P60E 2E amp ON Keyswitch cycles between Arm Monitor and Disarm CONTROL PANEL Zone 8 Input MOMENTARY KEYSWITCH Normally Open contacts 2810 a E C NESS D8 V4 CONTROL PANEL INSTALLER MANUAL P60E 4E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Tamper Reset Lockout enabled NOTES RELATED OPTIONS P44E Lockout zones PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Reset output on Duress alarm NOTES To Disarm with Duress add any of the digits 5 6 8 or 9 in front of the User Code when disarming P60E 6E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Auto Exclude enabled NOTES RELATED OPTIONS P62E 7E Siren burst on Auto Exclude P60E 7E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Display is always ON NOTES On the LCD keypad the display and display backlighting will turn off but the keys backlighting will remain on The keypad flap can be closed to reduce stray light from the keys P60E 8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF ARM1 amp ARM2 outputs are instant NOTES PROGRAMMIN
53. ON Supervision AUX2 output enabled RELATED OPTIONS P65E P66E 7E SUPERVISION TIME SPEEDUP X6 PROGRAM MODE LEVEL Setting this option speeds up the Supervision Time by 6 For instance if P67E is Installer Remote by PC set to 1 hour 60 minutes then this option will reduce it to 10 minutes i e 60 FACTORY DEFAULT divided by 6 OFF Supervision Time normal PROGRAMMING SEQUENCE NOTES RELATED OPTIONS P66E 7E toggles the option ON and OFF P67E Supervision Time P66E 7E OFF Supervision Time normal as set by P67E P66E 8E Supervision Time speedup x10 P66E 7E ON Supervision Time speedup x6 P66E 8E SUPERVISION TIME SPEEDUP X10 PROGRAM MODE LEVEL Setting this option speeds up the Supervision Time by 10 For instance if P67E Installer Remote by PC is set to 1 hour 60 minutes then this option will reduce it to 6 minutes i e 60 FACTORY DEFAULT divided by 10 OFF Supervision Time normal PROGRAMMING SEQUENCE NOTES RELATED OPTIONS P66E 8E toggles the option ON and OFF P67E Supervision Time P66E 8E OFF Supervision Time normal as set by P67E P66E 7E Supervision Time speedup x6 P66E 8E ON Supervision Time speedup x10 P66E 7E amp 8E are normally only used for Supervision testing purposes NOTE If both P6GE 7E and 8E are both ON then the Supervision time is sped up by 60 For instance if P67E is set to 1 hour 60 minutes then this option will reduce it to 1 minute i e 60 divided by 60 N
54. ORY DEFAULT Alarms if enabled are sent on activation Restorals if enabled are sent on see table Opening Mains Fail and Low Battery Restorals are sent when the power has NOTES been restored OE will turn all selections OFF MEMORY E will turn all selections ON PROGRAMMING SEQUENCE MISCELLANEOUS ALARMS PxxE 1E 8E 1E 1 Duress toggles the option ON and OFF ALARM 2E 2 Medical 77 9 P75E 3 Keypad amp K Switch Panic 4E 4 Fire REPORT MISCELLANEOUS RESTORALS 5 Panel T RESTORAL 5E gt ane famper PROGRAM MODE LEVEL m ge 6 External Tamper Installer Remote by PC 7 Keypad Tamper FACTORY DEFAULT 8 Exit Install Mode see table 1E 9 Radio Tamper NOTES 10 Radio Panic by User Mains Fail and Low Battery Restorals are 11 Radio Low Battery by Device 4E 12 Supervision Fail 5E 13 Panel Low Battery 6E 14 Mains Fail sent when the power has been restored OE will turn all selections OFF MEMORY E will turn all selections ON OPTION No DESCRIPTION Zone Restoral reporting optons ON Factory default setting RESTORAL REPORTING OPTIONS P82E 1E 4E This option selects when the dialler sends zone Restoral reports Only one of the following options may be selected PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT Restoral reporting options also apply to 24hr zones 4E ON Always send Restoral on Disarm NOTES PROGRAMMING SEQUEN
55. OS8E The hardwired zones 1 8 continue to operate in parallel Radio Keys can also operate on radio zones 1 8 for special purposes but they should normally be used as Radio Codes KEYSWITCH INPUT A Radio Device programmed to Zone 8 will still work as an alarm even if the Zone 8 input operation has been changed to Keyswitch operation The P60E 2E and options only affect the Zone 8 terminal inputs VIBRATION Radio device zone signals IGNORE the P30E P38E vibration sensor settings TAMPER REPORT Radio Device Tamper operation depends on the Armed State of the control panel RADIO TAMPER causes the keypad to continuously beep and also to flash the RADIO TAMPER and the ZONE identifying the detector lights Pressing any key on the keypad or sending a TAMPER RESTORE will clear this warning LOW BATTERY REPORT A low battery gives 10 beeps and flashes the RADIO amp the BATTERY light The ZONE light identifying the radio device is also ON The flashing lights stop when any key on the keypad is pressed or a detector code with no low battery is received Low Battery generates HISTORY and DIALLER reports ONCE only until the low battery is fixed and a restore report is received SUPERVISION If a zone has the P65E option ON and a radio code has been programmed for that zone then the supervision is active This means that the radio detector does not need to have its SUPER enabled via header link for the SUPERVISED timeout to occur Us
56. OTES RELATED OPTIONS P9QE 1E to 8E All Remote Access options P66666666E PROGRAM MODE LEVEL User Program Mode FACTORY DEFAULT not applicable P77777777E PROGRAM MODE LEVEL Installer User Program Mode FACTORY DEFAULT not applicable P88888888E PROGRAM MODE LEVEL Installer User Program Mode FACTORY DEFAULT not applicable PROGRAMMING OPTION No DESCRIPTION DEFAULT NOTE REQUIRED RINGS Sets the number of double rings before an incoming call is answered This is used for Remote Access Programmable from 1 to 16 rings Enter a value between 1 and 16 See below for a detailed description PROGRAMMING SEQUENCE P91E existing Required Rings value is displayed ENTER NEW VALUE E new Required Rings value is displayed EXAMPLE To make Required Rings 3 P91E3E SEND DIALLER TEST REPORT Send a Dialler Test Report in USER PROGRAM MODE Obviously at least one telephone number must be programmed P70E PROGRAMMING SEQUENCE P66666666E eight 6 s Triggers dialler and sends test report to Central Station SIREN TEST Turn the Siren Reset and Strobe Outputs On Pressing P E will stop the Siren Test and also exits Program Mode PROGRAMMING SEQUENCE P77777777E eight 7 s Triggers Siren Reset Strobe PANEL RESET This function resets the microprocessor The effect is the same as powering down and powering up again PROGRAMMING SEQUENCE P88888888E eight 8 s Panel Reset
57. RAMMING SEQUENCE P68E 8E toggles the option ON and OFF P68E 8E OFF Quiet Chirps disabled P68E 8E ON Quiet Chirps enabled NESS D8 V4 CONTROL PANEL INSTALLER MANUAL PROGRAMMING E gt tor Siren ss 5 5 S 68 o Ari Ming et Monj 5 a 5E 6E 7E 8E beeps gt gt Q e Qu rm 4 OPTION No DESCRIPTION E 2E 3 Pes Wiscelancousonfons ON Factory default setting ARM1 PULSE OUTPUT This option selects the ARM1 output to pulse on for 2 seconds whenever arming or disarming of 1 The ARM1 output normally toggles when arming disarming PROGRAM MODE LEVEL Note also that when Arming with the P60E 8E option selected that the pulse will rn Installer Remote by PC FACTORY DEFAULT OFF ARM1 output toggles occur at the end of Exit Time NOTES This is useful as a Smoke Detector reset output with an optional external relay PROGRAMMING SEQUENCE P69E 1E toggles the option ON and OFF P69E 1E OFF ARM1 output toggles RELATED OPTIONS P60E 8E Delay ARM1 ARM2 outputs P69E 1E ON ARM1 output pulses ARM2 PULSE OUTPUT This option selects the ARM 2 output to pulse on for 2 seconds whenever Arming or Disarming of Area2 The ARM2 output normally toggles when arming disarming PROGRAM MODE LEVEL Installer Remote by PC Note also that when Arming with the P60E 8E option selected that the pulse will
58. ROGRAMMING RADIO KEYS Radio Keys can be assigned to take the place of User Codes 2 to 15 User Code 1 is always a Keypad code PROGRAMMING SEQUENCE At option PO9E select which User Codes 2 8 will be Radio Codes At option P10E select which User Codes 9 15 will be Radio Codes Use P12E to P25E to select a User Code The User Code selected must already be assigned as a Radio Code by options or P10E Press 1E The READY light will turn ON to indicate that the User Code is ready to accept the Radio Key If a code is already programmed the READY light will not turn on and a warning beep will sound To clear the code press OE then go back to step 3 0E clears any Keypad Codes and Radio Keys Press the OFF button on the Radio Key to be programmed If the Radio Key is accepted the READY light will turn off and 3 beeps will sound If the READY light stays on and a warning beep sounds the Radio Key is already assigned to another User Code and must be cleared from that User Code first EXAMPLE To program a Radio Key at User Code 9 P10E 1E P19E 1E then Press the OFF button on the Radio Key DELETING A RADIO CODE Use P12E to P25E to select the User Code Q Press OE to clear the code 3 beeps will sound CODE TABLE a P11E Master Code 123 User Code 2 User Code 3 User Code 4 User Code 5 User Code 6 User Code 7 User Code 8 User Code 9 User Code 10 User Code 11 User Code 12 User Code 13 User Code 14
59. S P65E Radio Supervision Zones P66E 1E 6E Radio Supervision Alerts P66E 7E 8E Supervision Time Speed up See Page 56 for Radio Device programming PROGRAMMING Zones OPTION No DESCRIPTION 1 2 3 4 5 6 7 8 mE T T T T I ON Factory default setting SUPERVISED RADIO ZONES This option assigns zones that will operate as Radio Supervised types Supervised signals failure is reported as per the P66E output options when no signal is received from a Radio Supervision Zone for the Supervision Time P67E Radio Supervision for any zone is not enabled unless a Radio PIR is assigned to the zone PO1E PO8E PROGRAMMING SEQUENCE P65E Zone No E toggles the options ON and OFF P65E Zone No E OFF The zone is not a Supervised Radio zone P65E Zone No E ON The zone is a Supervised Radio zone RADIO SUPERVISION ALERTS SUPERVISION TIME SPEEDUP See pages 32 33 SUPERVISION TIME The SUPERVISION TIME is the time allowed between radio transmissions received by the D8 from any Supervised Ness Radio PIR 100 663 The SUPERVISION TIME setting is from 01 to 24 hours PROGRAMMING SEQUENCE P67E existing time is displayed ENTER NEW TIME E new time is displayed EXAMPLE To program SUPERVISION TIME to be 4 hours P67E 04E RADIO SUPERVISION The purpose of Radio Supervision is to verify the correct operation of Ness Radio PIRs The Supervision signal from the Radio PIR tells the panel that the device
60. T OFF No Strobe Flash on kiss off PROGRAMMING SEQUENCE c P88E 4E toggles the option ON and OFF i P88E 4E OFF No Strobe Flash on kiss off P88E 4E ON Strobe Flash on kiss off enabled RELATED OPTIONS P88E Siren Chirp on kiss off NESS D8 V4 CONTROL PANEL INSTALLER MANUAL P88E 5E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Forced opening Reports enabled NOTES This option is used to indicate to the Central Station that an alarm has been reset by a valid user Usually used in cases where Open Close reports are normally selected OFF P88E 6E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Closing Reports sent on Arming NOTES RELATED OPTIONS P88E 1E AREA1 Open Close reports P88E 2E AREA2 Open Close reports P88E 7E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Manual Exclude Reports enabled NOTES RELATED OPTIONS P88E 8E Auto Exclude Reports P88E 8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Auto Exclude Reports enabled NOTES P88E 7E Manual Exclude Reports PROGRAMMING FORCED OPENING REPORT If Forced Opening Report is selected ON when an alarm has been reset by a valid User Code or Radio Key the dialler will send an Opening report along with a restoral report for the zone or miscellaneous input which caused the alarm PROGRAMMING SEQUENCE P88E 5E toggles the option ON a
61. Test Calls must be enabled by option P89E 1E PROGRAMMING SEQUENCE P83E existing Test Call Interval time is displayed ENTER NEW TIME E new Test Call Interval time is displayed EXAMPLE To program daily test calls P83E12E TIME BEFORE NEXT TEST CALL This option sets the time before the next Test Call and is used to set the preferred time for Test Calls Programmable from 2 to 198 Hours Enter a value between 1 and 99 This is automatically multiplied by 2 EXAMPLES A New Installation Set the time before the first test call E g If you are programming the panel at 5pm and you want test calls to be sent at 1am Enter P84E 4E 4 x 2 8hrs Therefore 5pm 8hrs 1am B Existing Installation To reset the time that test calls are sent E g Our example panel is sending test calls at 1am and you want to change it to 2am If you are programming the panel at enter P84E 4E 4 x 2 8hrs Therefore 6pm 8hrs 2am PROGRAMMING SEQUENCE P84E existing Time Before Next Test Call is displayed See note 3 ENTER NEW TIME E new Time Before Next Test Call is displayed OPTION No DESCRIPTION 1E P85E Dialing Method joN J ON Factory default setting DIALLING METHOD The dial format is determined by the detected Dial Tone By default if no dial tone is detected after looping the line then the dialler will attempt to dial regardless alternating between PULSE Decadic first and then DTMF dial
62. VEL Installer Remote by PC FACTORY DEFAULT 2E ON Zone 2 is a Handover zone NOTES When a zone is selected for this type it is automatically deselected from any other zone type in the DELAY GROUP PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT all OFF No zones have Entry Delay2 NOTES When a zone is selected for this type it is automatically deselected from any other zone type in the DELAY GROUP PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT all ON All zones are Lockout zones NOTES The SIREN output always locks out OE will turn all selections OFF MEMORY E will turn all selections ON RELATED OPTIONS P60E 4E Tamper Reset Lockout P45E P46E P47E P50E PROGRAMMING HANDOVER ZONES Handover zones are delayed only if entry is made through an Entry Delay zone first If a Handover zone is triggered first the zone behaves as an instant zone Normally the point of entry zone should be Delay zone with any other zones in the entry path programmed as Handover zones PROGRAMMING SEQUENCE P42E Zone No E turns the options ON P42E Zone ON The zone is a Handover zone To deselect the option select a different zone type in the DELAY GROUP ENTRY DELAY2 ZONES When an Entry Delay2 zone is triggered it has entry delay as set by the Entry Delay Time2 P27E PROGRAMMING SEQUENCE P43E Zone NoJE turns the options ON P43E Zone ON The
63. able Remote Arming Enable Remote Disarming Enable Remote AUX control Enable Remote Status report Enable Remote Event Report Enable Callback Mode Required rings to answer Report Radio Tamper 40 41 Report Radio Panic by User Report Radio Battery by device Report Supervision fail Report Panel Battery Report Mains Fail Report misc ALARMS 9 14 SS Report MISC Restorals 9 14 Clear Radio Devices 3E S cut Monitor Mode v x a Report Zone Restorals 1 8 All zones Clear Memory 4E S cut Keypad Panic Report MISC Restorals 1 8 All on Clear panel options 5E S cut Area 1 Arm 6E S cut Area 2 Arm Auto Exclude 2s Warn Report Multiple Zone alarms Account No 2 Zones Telephone No 3 for Test Calls none 8E Exit Time x 10 D8 V4 Options Summary 2001 Ness Security Products Telephone No 4 for Callback NESS D8 V4 CONTROL PANEL INSTALLER MANUAL Clear User codes Set Installer code 000000 These options are available in User Program Mode ALL options are available in Installer Program Mode INSTALLATION RECORD D amp Date purchased Date installed Installation Company Telephone DIALL
64. able from the SIREN and RESET outputs and 200mA from the STR output Recommended maximum power load 3 x Horn speakers SIREN output 2 x Strobe lights STR output 2 x Ness Internal Sirens 100 172 RESET output Note This assumes no more than 500 is being drawn from the 12V device output J3 OPEN COLLECTOR OUTPUTS AUX 1 AUX2 ARM 1 ARM2 12V OUTPUTS 12 VOLT OUTPUT A regulated 13 8 VDC output is available to power detectors and other equipment This output is available from two sets of terminals marked 12V and OV The output is protected by an Automatic Reset fuse A maximum load of 500mA may be connected to these terminals SIREN The on board siren driver will drive a maximum of 3 x 8 ohm horn speakers Ness Part No NOI110 or 100 171 Internal Siren The output will reset at the end of siren time P29E or whenever the panel is reset whichever comes first The output is protected by an Automatic Reset fuse STR Strobe A latched 12VDC output for connecting strobe lights This output will latch on in the event of an alarm condition and stay on until the panel is reset A maximum of 2 x 1 Watt Strobes Ness Part No NOI300 can be connected to this output The output is protected by an Automatic Reset fuse RESET A 12V DC output for connecting Ness Sirens piezo sirens or relays etc This output will reset at the end of siren time P29E or whenever the panel i
65. all ON All zones trigger Keypad Sonalert NOTES OE will turn all selections OFF MEMORY E will turn all selections ON PROGRAMMING ZONE TO OUTPUT MAPPING When a zone alarms it can turn on any or all of the following 6 outputs Sonalert Strobe Siren Reset AUX1 AUX2 The programming is selected with options P54E P59E Simply set the zone number to the output to select it The zone LED will indicate if the zone is se lected The Tamper Input and the Keypad Panic can be programmed to turn on the Re set Strobe Sonalert and Siren by using option P61E ZONE TO OUTPUTS MAPPING Zones OPTION No DESCRIPTION 12 3 4 5 6 7 8 Reset zones Strobe zones Sonalert zones Siren zones Aux1 zones Aux2 zones So SO Factory default setting RESET OUTPUT ZONES Selects the zones to trigger the Reset output PROGRAMMING SEQUENCE P54E Zone toggles the options ON and OFF P54E Zone OFF The zone will not trigger the Reset output P54E Zone ON The zone will trigger the Reset output STROBE OUTPUT ZONES Selects the zones to trigger the Strobe output PROGRAMMING SEQUENCE P55E Zone No E toggles the options ON and OFF P55E Zone No E OFF The zone will not trigger the Strobe output P55E Zone No E ON The zone will trigger the Strobe output KEYPAD SONALERT ZONES Selects the zones to trigger the Keypad So
66. always P78E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT No zones report Multiple Alarms NOTES Only zones that have previously sent an Alarm will send a Restoral OE will turn all selections OFF MEMORY E will turn all selections ON RELATED OPTIONS P89E 4E Swinger shutdown P79E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All zones report Restorals NOTES PROGRAMMING Zones OPTION No DESCRIPTION 1 2 3 4 5 6 7 8 Report zone alarms Report zone restorals Multiple zone alarms Account No 2 zones ON Factory default setting REPORT ZONE ALARMS This option selects which zone inputs will send Alarm reports to the Central Station PROGRAMMING SEQUENCE P74E Zone No E toggles the option ON OFF P74E 1E 8E OFF Alarm reporting disabled for that zone P74E 1E 8E ON Alarm reporting enabled for that zone REPORT ZONE RESTORALS This option selects which zone inputs will send Restoral reports to the Central Station Only zones that have previously sent an Alarm will send a Restoral PROGRAMMING SEQUENCE P76E Zone No E toggles the option ON and OFF P76E 1E 8E OFF Restoral reporting disabled for that zone P76E 1E 8E ON Restoral reporting enabled for that zone REPORT MULTIPLE ZONE ALARMS Zones selected for Multiple Zone Alarms will report each time the zone alarms and without a restore being sent The numb
67. amming is completed NESS D8 V4 CONTROL PANEL INSTALLER MANUAL PO9E P10E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT No Radio Codes NOTES All User Codes can be Radio Codes except User Code 1 Master Code which is always a Keypad Code Each User Code 2 15 can be either a Radio Code or a Keypad Code not both Radio Key programming is done by learning the code by radio Radio Codes can only be deleted by keypad in the case of a lost Radio Key Radio Keys are allocated to User Codes so that Open Close reports are identified by user number when the control panel is base station monitored If Open Close reports are enabled Radio Codes cannot be made Arm Only TIP When adding Radio Keys start at e g User Code 9 This will keep codes 1 to 8 free for use as Keypad Codes RELATED OPTIONS 1 Programming Radio Devices 100 664 Radio Key ASSIGN RADIO CODES User gt 234567 8 Codes PROGRAM POSE User Codes 2 8 Note User Code 1 is always a keypad code User 9 10 1112 13 14 15 Codes PROGRAM P10E User Codes 9 15 NESS RADIO RADIO CODES Each of the 15 User Codes except for the Master Code can be programmed to be Radio Codes This allows up to 14 Ness Radio Keys to be used for Arming and Disarming of the panel The optional 100 200 Ness Radio Interface is required for Radio Keys to operate P
68. ce Suffix Event checksum Test Report AAAA Q 602 01 063 k Mains Fail AAAA Q 301 01 050 k Panel Battery Fail AAAA Q 309 01 051 k Open AAAA Q 402 GG by User k Close AAAA Q 402 GG by User k Cancel AAAA Q 406 GG by User k Zones 1 8 Manual Exclude AAAA 573 GG 001 008 k Zones 1 8 Auto Exclude 380 GG 001 008 k NESS D8 V4 CONTROL PANEL INSTALLER MANUAL PROGRAMMING 5 gt 2 o 5 SS Ei a oc CAES cx ss S GG I 1E 2E 3E 4E 5E 6E 7E OPTION No DESCRIPTION Pere mscetaneous Darmo Onions Jon ON Factory default setting SPLIT DIAL PRIMARY SECONDARY PHONE NUMBERS P87E 1 This option selects the order in which Telephone numbers 1 amp 2 are dialled PROGRAM MODE LEVEL PROGRAMMING SEQUENCE Installer Remote by PC FACTORY DEFAULT OFF Alternate Dial NOTES RELATED OPTIONS P87E 4E Number of Dialling attempts P87E 2E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Dial only with dial tone NOTES P87E 4E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON 4 dialling attempts NOTES Sets the total number of dialling attempts E g If 4 dialling attempts is selected this means 2 attempts per telephone number RELATED OPTIONS P87E 1E Alternate dialling P87E 1E toggles the option ON and OFF P77E 1E OFF Alternate Dial Dial Telephone No 1 on the first attempt If no an
69. d with 3 beeps if it recognises the code or 1 long beep to signal the code was invalid and to try again 6 Enter the required command See Summary Of Telephone Commands 7 Press x st to finish This tells the D8 to hang up Also hang up your telephone NESS ACCESSORIES 100 021 100 226 100 210 Quantum Quantum Plus Quantum Dual mS AUSTRALIA MOTION DETECTORS Ness manufactures a range of high quality and efficient motion detectors including passive infra red detectors dual technology microwave and infra red devices as well as ceiling mounted 360 detectors All Ness detectors are designed using the most modern technology and techniques that ensure superior reliability and performance QUANTUM 15m passive infra red detector with selectable pulse count suitable for domestic and commercial installations PetAware model available QUANTUM PLUS 15m passive infra red detector with selectable pulse count temperature compensation and downward looking creep zones QUANTUM DUAL 15m combination microwave and passive infra red detector This combination of detection technologies virtually eliminates the possibility of unwanted alarms but faithfully detects humans PetAware model available QUANTUM 360 Ceiling mounted 360 passive infra red detector with selectable pulse count and sensitivity Provides 8 metre coverage mounted at standard 2 4 metre ceiling heig
70. ds NOTES Programmable from 1 99 seconds RELATED OPTIONS P62E 8E Exit Time x10 PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 5 minutes NOTES Programmable from 1 99 minutes Siren times of longer than 5 minutes are contrary to noise pollution regulations in most areas PROGRAMMING OPTION No DESCRIPTION DEFAULT NOTE Entry Delay Time 1 Seconds Entry Delay Time 2 Exit Delay Time Seconds x10 60 seconds Siren Reset Time Minutes ENTRY DELAY TIME1 The Entry Delay Time 1 is the time given to Disarm the Panel after a Entry Delay 1 zone is unsecured The Entry Delay Time1 setting is from 1 to 99 seconds PROGRAMMING SEQUENCE P26E existing time is displayed ENTER NEW TIME E new time is displayed EXAMPLE To program Entry Delay Time1 to be 30 seconds P26E 30E ENTRY DELAY TIME2 The Entry Delay Time2 is the time given to Disarm the panel after an Entry Delay2 zone is unsecured The Entry Delay Time2 setting is from 10 to 990 seconds 1 99 Note The Entry Delay Time2 is set in 10 second increments so that a value setting of 6 means a 60 seconds delay PROGRAMMING SEQUENCE P27E existing time is displayed ENTER NEW TIME E new time is displayed EXAMPLE To program Entry Delay Time2 to be 600 seconds P27E 60E EXIT DELAY TIME The Exit Delay Time is the time given to secure and depart the premises after the Panel is Armed All zones e
71. e I ees 8 6 2 At P86E turns ON option 2 Central station Monitoring enabled 7 0 Selects the option for Telephone No 1 Existing Ph if any displayed OC votes dots E Enter the Telephone Number Can be up to 15 digits long X GG Enter the Account Number Must be 4 digits exit Program Mode Program light turns OFF 1 Option P86E 2E is ON by factory default This option only needs to be turned ON if previously programmed OFF 2 The Central Station s receiver telephone number supplied by the Central Station 3 Account Number to identify the premises supplied by the Central Station Factory default Master Code is 123 Factory default Installer Code is 000000 NESS D8 V4 CONTROL PANEL INSTALLER MANUAL FACTORY DEFAULT MASTER CODE 123 INSTALLER CODE 000000 INSTALLER PROGRAM MODE Installer Program Mode allows access to ALL program options Note The panel will remain in Installer Program Mode indefinitely USER PROGRAM MODE User Program Mode allows the owner to program All User Codes Entry Exit Times Follow Me Telephone number Note The panel will automatically drop out of User Program Mode to Operating Mode if no keypad buttons are pressed for 4 minutes d NG SOS 6 PROGRAMMING PROGRAM MODE LEVELS TABLE 4 FLOW CHART Power up with Program Link OFF Usually on first time installat
72. ed P66E 1E ON Supervision Reset output enabled RADIO SUPERVISION ALERTS STROBE OUTPUT Setting this option turns the Strobe output ON when a SUPERVISED RADIO alert occurs The Strobe output will remain ON until the panel is disarmed PROGRAMMING SEQUENCE P66E 2E toggles the option ON and OFF PROGRAM MODE LEVEL Installer Remote by PC P66E 2E OFF Supervision Strobe output disabled P66E 2E ON Supervision Strobe output enabled FACTORY DEFAULT OFF Supervision Strobe output disabled NOTES RELATED OPTIONS P65E Supervised Radio Zones RADIO SUPERVISION ALERTS KEYPAD SONALERT amp DELAY ALL SUPERVISION OUTPUTS alert occurs The Keypad Sonalert remains ON until any keypad key is pressed Also turning this option ON makes all Supervision outputs delayed by one PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Supervision Keypad Sonalert disabled Setting this option turns the Keypad Sonalert ON when a SUPERVISED RADIO minute PROGRAMMING SEQUENCE P66E toggles the option ON and OFF NOTES When this option is turned ON it delays the operation of all other selected Supervision outputs by one minute P66E 3E OFF Supervision Keypad Sonalert disabled AND all Supervision outputs trigger instantly P66E 3E ON Supervision Keypad Sonalert enabled AND all Supervision outputs are delayed by 1 minute RELATED OPTIONS P65E Supervised Radio Zones NESS D8 V4 CONTROL PANEL INSTALLER MANUAL
73. eful as an inactivity alarm A zone supervision failure always flashes the identifying ZONE light and the RADIO light RADIO SUPERVISION The purpose of Radio Supervision is to verify the correct operation of Ness Radio PIRs The Supervision signal from the Radio PIR tells the panel that the device has not been removed from radio range and is in working order Non SUPERVISION Radio PIRs can also be programmed and used with the D8 SUPERVISION TIMERS A non SUPERVISION enabled Radio PIR will transmit signals to the D8 only when it has detected an event Obviously there is no guaranteed signal period In either case when the allowed time limit is exceeded then a WARNING is first given if programmed by P66E 3E and then after 1 minute the programmed RADIO SUPERVISION ALERTS are generated by the D8 NOTE Manually Excluding a Supervised Zone will also disable Radio Supervision for that zone NESS D8 V4 CONTROL PANEL INSTALLER MANUAL PO1E PO8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT No Radio Devices programmed NOTES Radio Device programming is done by learning the code by radio Radio Devices codes can only be deleted by keypad Some Ness Radio Devices send separate Alarm and Restore signals Ness Radio Keys 100 664 can also be programmed to operate on radio zones but they are normally used to operate Radio Codes as described on page 57 Late model Ness Radio PIRs 1
74. er of reports is a maximum of 15 The number of alarms sent for each Multiple Zone Alarm can be reduced to 3 by using the swinger shutdown option P89E 4E Zones not selected report only once until reset by an opening or a valid code PROGRAMMING SEQUENCE P78E Zone No E toggles the option ON OFF P78E 1E 8E OFF Multiple Zone Alarms disabled for that zone P78E 1E 8E ON Multiple Zone Alarms enabled for that zone ACCOUNT NO 2 ZONES Zones selected to be Account No 2 zones will report their Alarms Restorals and Excludes on Client code 2 PROGRAMMING SEQUENCE P79E Zone No E toggles the option ON OFF P79E 1E 8E OFF Multiple Zone Alarms disabled for that zone P79E 1E 8E ON Multiple Zone Alarms enabled for that zone NESS D8 V4 CONTROL PANEL INSTALLER MANUAL PROGRAMMING n ee zs ss Q 3S e c d u u OPTION No DESCRIPTION waa EE E va vo P75E Report Misc Alarms 1 8 ON ON ON ON 92 Report Misc Alarms 9 14 ON ON ON ON P77E Report Misc Restorals 1 8 ON ON ON ON ON P93E Report Misc Restorals 9 14 ON ON ON ON ON ON ON ON Factory default setting REPORT MISCELLANEOUS ALARMS P75E P92E REPORT MISCELLANEOUS RESTORALS These options select which Miscellaneous alarms will trigger the dialler to send REPORT MISCELLANEOUS ALARMS Alarm reports and Restoral reports to the Central Station PROGRAM MODE LEVEL Installer Remote by PC FACT
75. ggered when the panel is in MONITOR and DAY modes For ZONE TO OUTPUT MAPPING Armed amp 24hr states see Options P54E P59E page 22 NESS D8 V4 CONTROL PANEL INSTALLER MANUAL PROGRAMMING E S SQ wy 4 amp E dS o d E 5 5 5 lt E lt gt c v lt uS S oS S 5 Sas aLe vo o N wg LTS S 5 E c v SsSssSEBERB o gt amp SSS Ww E 3E 4E 5E 6E 7E 8E OPTION No DESCRIPTION 1E 2 wisceaneousoptons onfon ON Factory default setting 2 SECOND MONITOR MODE ALARM Alarms in Monitor Mode can either activate the programmed outputs for Siren Time duration P29E or they can activate the outputs for 2 seconds only PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Monitor Mode outputs normal time PROGRAMMING SEQUENCE P64E 1E toggles the option ON OFF RELATED OPTIONS P64E 1E OFF Monitor Mode outputs have normal time as set by P29E P51E Set Monitor zones P64E 1E ON Monitor Mode outputs are ON for 2 seconds only P63E 1E 4E Monitor Mode output mapping 2 SECOND DAY MODE ALARM PROGRAM MODE LEVEL Alarms in Day Mode will activate the programmed outputs while the zone is Installer Remote by PC unsealed or they can activate the outputs for 2 seconds only FACTORY DEFAULT ON 2 secDay Mode outputs PROGRAMMING SEQUENC
76. ging the top closed Push hard to ensure the LED KEYPAD KEYPAD D8 KEYPAD The D8 control panel may be supplied with either the LED keypad 100 192 or the Ness LCD Keypad 100 667 The keypad provides important visual and audible indications and is the main interface for operating and programming the D8 control panel NUMBER OF KEYPADS Up to 3 LED and or LCD keypads can be connected to the D8 105mm Zones 1 2 3 4 5 6 7 8 OReady O Armed O Arm 2 O Mains O Battery O Radio O Line O Program O Memory Exclude Tamper Not Ready light MEMORY button PANIC buttons I MEMORY PANIC ARM button mm C2 Ce MONITOR button Cowo EXCLUDE button ease C C8 PROGRAM button ENTER button I PROGRAM 0 ENTER clips engage Attach the Zone list label on the inside of the lid Protective flap not shown KEYPAD BEEPER SOUNDS Each key press LED KEYPAD 4 1 beep Valid command CABLE LENGTH The maximum allowable cable length is 100m total cable length to all keypads DISPLAY TEST LCD Keyad only To display all the keypad icons press and hold the button for at least 2 seconds All the icons will be on whilst the button is held down Display Test can be activated at any time either in operating mode or a
77. he option ON and OFF external devices using Radio Key s Panic P68E 3E OFF Radio Key Panic triggers control panel Panic button E g lighting garage doors When this option is selected ON the Radio Key Panic function is disabled PROGRAM MODE LEVEL Installer Remote by PC P68E 3E ON Radio Key Panic toggles AUX1 RADIO KEY PANIC PULSES AUX1 Setting this option ON changes the action of the Radio Key Panic button so that P68E 4E the AUX1 output is pulsed ON for 2 seconds That is momentary ON for 2sec If a 4 Button Key is used then this option can be used with the 4th key instead of the Panic key using P68E 7E This then allows the Panic key to still activate FACTORY DEFAULT OFF Radio Key Panic to AUX1 disabled Panic reports PROGRAMMING SEQUENCE P68E toggles the option ON and OFF NOTES When this option is selected ON the Radio Key Panic function is disabled e f P68E and are both selected ON then 4E has priority P68E 4E OFF Radio Key Panic triggers control panel Panic P68E 4E ON Radio Key Panic pulses AUX1 NESS D8 V4 CONTROL PANEL INSTALLER MANUAL P68E 5E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Radio Key siren warning disabled NOTES P68E 6E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No 24hr Fire siren sound NOTES The keypad key sequence for FIRE 3 E always outputs the FIRE siren sound P68E 7E
78. housing should be in an area that is within the protected area of the premises A linen closet or cupboard are good examples as these are generally located in the centre of the Premises Positioning of the movement detectors should be considered as the incorrect position may cause unwanted alarms 1 Unclip the lid by pushing in the directions of the arrows 1 and 2 as shown below 2 Remove the Battery from the base 3 Mountthe rear panel housing to a secure location 4 Insert the PCB stand offs in the Panel and then plug the circuit board onto the stand offs 5 Wire to the circuit board terminal blocks as per the wiring instructions shown in this installation manual 6 Replace the Battery 7 Insert the panel tamper bracket as shown at left 8 Program the control panel as required SPECIFICATIONS Box construction 3mm Polycarbonate equiv 1 2mm mild steel Box Dimensions 223W x 300H x 85D mm Plug Pack 240Vac output 17Vac 1 4A Power Supply 13 8Vdc 800mA Quiescent Current 80mA with 1 Keypad Operating Voltage 9 5V 14V dc Rechargeable Battery 12 volt 7 0 Amp hour lead acid Battery Charging current 350mA maximum current limited Dynamic Battery Test Every Hour and on arming 10 75V with a 5 amp load F S68 oie dosis 2 Amp resettable sirens amp reset 500mA resettable 12 volt auxiliary outputs 200 mA resettab
79. ht PET AWARE DETECTORS The Ness Quantum Pet Aware PIR and Pet Aware DUAL are able to discriminate between household pets and unwanted human intruders allowing you to secure your home with your pets indoors WARNING DEVICES The range of warning devices includes horn speakers polytough siren covers internal screamers and satellite sirens with their own battery backup CCTV The Ness range of Closed Circuit TV equipment includes Dome cameras B W or Colour cameras Miniature hidden cameras Monitors even digital video recorders and remote telephone video systems SWITCHES A variety of switches are available for protecting doors and windows The line up includes surface and flush mount reed switches emergency buttons roller door reed switches and the unique Nessensor vibration sensor for highly effective perimeter protection NESS D8 V4 CONTROL PANEL INSTALLER MANUAL MADE W AUSTRALIA f o lil l we E a P wa PET AWARE pe DETECTORS Pet Aware model also available T WIRELESS PRODUCTS RADIO ACCESSORIES Ask your installer about the range of Ness radio devices for the optional extra convenience of wireless remote control and wireless detection Operating your Ness security system can be as convenient as opening your car door The Ness Radio Key provides the benefits of separate ON OFF
80. ion my 8 PROGRAM PROGRAM light is FLASHING Mata PROGRAM LIGHT IS FLASHING INSTALLER CODE E Factory default Installer Code 000000 PROGRAM light is ON USER PROGRAM Mode PROGRAM PROGRAM LIGHT IS ON P MASTER CODE E Factory default Master Code 123 NORMAL OPERATING Mode PROGRAM LIGHT IS OFF HOW TO ENTER PROGRAM MODE Q FROM POWER UP 1 Power up with the PROG link OFF The PROG link or Box Tamper lead must be ON in Operating Mode USING KEYPAD The panel must be Disarmed 1 Press P MASTER CODE The keypad will respond with 3 beeps JJ JJ This is User Program Mode PROGRAM light is ON 2 Press P INSTALLER CODE E The keypad will respond with beeps J J This is Installer Program Mode PROGRAM light is FLASHING HOW TO EXIT PROGRAM MODE 1 Press P then E This is Operating Mode PROGRAM light is OFF Selects a program The current value Enter new option address is displayed data The keypad lights or MODE P icons will display the C C E ddd current value E Sg Bo a N ENTER button Enter new value using keys 0 9 ENTER button PROGRAM button NESS D8 V4 CONTROL PANEL INSTALLER MANUAL PO1E P10E PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT User Code 1 123 Installer Code 000000 All other codes blank
81. lay Arm1 2 outputs Tamper to Reset OP Tamper to Strobe OP Telephone No 2 Secondary Account No 1 Account No 2 Report ZONE Alarms 1 8 All zones Tamper to Sonalert Tamper to Siren KP Panic to Reset OP KP Panic to Strobe Op KP Panic to Sonalert 1E KP Panic to Siren S cut Memory display 2E S cut Zone Exclude x Report Duress OFF Report Medical OFF Report K P amp K S Panic ON Report Fire OFF Report Panel Tamper ON Report External Tamper ON Report Keypad Tamper ON Report misc ALARMS 1 8 Report Exit Install Mode OFF Time before next Test Call Auto Dialling Pulse amp DTMF 6 12 hours Pulse Dialling always DTMF Dialling always Disable Dialler Contact ID format Audible DTMF format Audible PULSE Format Contact ID Audible DTMF Contact ID Audible PULSE Split Dial Pri Sec Phone Nos Check for Dial Tone 4 Dialling attempts AREA 1 Open Close reports AREA 2 Open Close reports Siren Chirp on Kiss off Flash Strobe on Kiss off Forced Opening report Delayed Closing Reports Manual Exclude Reports Auto Exclude Reports Enable Test Calls Mains Report Delay Listen In to Dialler Swinger shutdown Line Fault Monitor Line Fault to AUX2 Enable Up Download Enable Direct Connect En
82. le strobe output INPUTS ient 8 x Zone inputs 2 x 24hr Tamper inputs End of line resistor 2200 Ohm Remote Keypad input Proprietary Maximum Keypads 3 J2 Header Multi pin connector for the Ness Radio Interface 100 200 OUTPUTS SIOM ziii ems On board siren driver Timed output Maximum 3 x 8 Ohm horn speakers 12V DC latching output Maximum 2 x 1 Watt strobe lights 12V DC timed output Maximum 3 x 12V piezo screamers Equipment power output 13 8V DC output for powering detectors and other equipment Maximum 500mA Header Multi pin connector provides the outputs AUX1 AUX2 ARM1 ARM2 12V DC NESS D8 V4 CONTROL PANEL INSTALLER MANUAL AYALLVE SLONGOUd ALIHNDIS SSAN TELEPHONE HEATSINK CONNECTION DIAGRAM OO SO SSS S SSS FS SSS S SSS OFS SS ZONE CONNECTION EXAMPLES N C Normally Closed Devices NESS D8 Zone N O Normally Open Devices NESS D8 Zone N C Contacts lO Contacts 262 amp Zone 8 E Zone 7 amp Zone 6 Zone 5 amp Zone 4 E Zone 3 amp Zone 2 X Zone 1 12V DC Power for detectors etc See CONNECTION EXAMPLES for end of line resisto
83. ling PROGRAMMING SEQUENCE P85E 1E 3E turns the option ON P85E 1E Auto Dialling PULSE or DTMF P85E 2E Pulse Dialling always P85E 3E DTMF Dialling always NESS D8 V4 CONTROL PANEL INSTALLER MANUAL PROGRAMMING di S ou KR eee BEES w KR OG S S s x X 1E 2E 3E 4E 5E 6E 7E 8E OPTION No DESCRIPTION P86E Reporting Formats jon ON Factory default setting P86E 1E DISABLE DIALLER This option disables the dialler even if telephone numbers and other dialler options are programmed PROGRAM MODE LEVEL Installer Remote by PC Up download or remote telephone access remain enabled FACTORY DEFAULT Off dialler enabled NOTES PROGRAMMING SEQUENCE This option is useful for temporary P86E 1E turns the option ON P86E 1E ON Dialler disabled disabling of the dialler without affecting other dialler options Only one option in the range P86E 1E 6E is allowed to be ON CONTACT ID FORMAT This option enables the reporting of alarms to a Central station via telephone 8 2 numbers 1 amp 2 using Contact ID format PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Contact ID format enabled PROGRAMMING SEQUENCE P86E 2E turns the option ON NOTES P86E 2E ON Contact ID format enabled Only one option in the range P86E 1E 6E is allowed to be ON AUDIBLE DTMF FORMAT P86E 3E PROGRAM MODE LEVEL For Audible Monitoring to any telepho
84. ll other Radio Devices is tested in INSTALLER PROGRAM Mode PRESS 3E to test the signal strength of the selected transmitter ONLY Other devices will be ignored PRESS 4E to test the signal strength of ANY Ness transmitter including unprogrammed devices WEAK 1 8 BEST SIGNAL SIGNAL 1 beep 8 beeps PROGRAM NESS RADIO RADIO QUICK START PROGRAMMING RADIO KEYS Select which User Codes 2 8 will be Radio Codes PO9E P10E Select the User Code P12E P25E Press 1E The READY light will turn ON to indicate that the User Code is ready to accept the Radio Key Press the OFF button on the Radio Key to be programmed If the Radio Key is accepted the READY light will turn off and 3 beeps will sound PROGRAMMING RADIO DEVICES Radio PIRs etc Select a zone to which the Radio PIR will be assigned PO1E POSE Press 1E The READY light will turn ON to indicate that the zone is ready to accept the Radio Device Trigger the Radio Device If the Radio Device is accepted the READY light will turn off the ARMED light will turn on and 3 beeps will sound NESS RADIO INTERFACE The Ness Radio Interface 100 200 is the optional radio receiver required to enable all radio functions Connection to the control panel is via a 4 wire loom and plug supplied with the Ness Radio Interface If the Ness Radio Interface is correctly installed the D8 keypad will flash the RADIO light ON when any radio signal is detec
85. mal Tamper alarm RADIO RADIO Normal Indicates that a Radio Key or other radio device has a low battery Receiving radio signal And in Memory Mode indicates a low battery alarm from a radio device LINE E LINE Normal Phone line fault or Dialler is on line failure to communicate PROGRAM PROGRAM Normal User Program Mode Installer Program Mode Not Ready Ready to Arm Not ready to Arm NESS D8 V4 CONTROL PANEL INSTALLER MANUAL eee OPERATION SUMMARY OPERATION J LED KEYPAD LCD KEYPAD Or User Code 2 User Code User Code User Code E P69E 5E must be ON Both keys together Cox Ce 2 Both keys together CPE User Code CENTER Cx D User Code PANIC Keypad Panic Shortcut Cx Keypad Panic Shortcut Or C PANIC ENTER must be ON P62E 4E E must be ON P62E 4E Press and hold for 4 seconds P68E 3E amp 4E must be OFF MONITOR MODE T or User Code VLC x User Code x User Code KEYPAD DURESS To Disarm and report a Duress Alarm add any of the digits 5 6 8 or 9 before the User Code when Disarming EXCLUDING ZONES or amp w User Code Or User Code Zone No Enter the zone numbers Zone No E Enter the zone numbers Zone No to be Excluded Zone No E to be Excluded To exit Exclude mode E To exi
86. mp 2 2 38 Telephone Number Test Calls 39 Telephone Number 4 Callback 39 Follow me Telephone Number 39 Report zone alarms eene 40 Report zone restorals 40 Report multiple zone alarms 40 Account No 2 zones renia aiaa a 40 Report Miscellaneous alarms 41 Report Miscellaneous Restorals 41 Restoral Reporting options 41 Test Call Interval eere 42 Time before Next test 42 Dialling Method 42 Disable Dialler teet 43 Contact ID format eeeeeeee eene 43 Audible format 43 Audible Pulse format eene 43 Contact ID Reporting Codes 44 Alternate Dialling ee 45 Check for dial tone sse 45 Number of Dialling Attempts 45 Areal open close reports 46 Area2 open close reports 46 Siren Chirp on kiss off
87. nalert beeper PROGRAMMING SEQUENCE P56E Zone No E toggles the options ON and OFF P56E Zone OFF The zone will not trigger the Keypad Sonalert P56E Zone No E ON The zone will trigger the Keypad Sonalert NESS D8 V4 CONTROL PANEL INSTALLER MANUAL P57E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT all ON All zones trigger Siren output NOTES OE will turn all selections OFF MEMORY E will turn all selections ON PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT all OFF No zones trigger AUX1 NOTES OE will turn all selections OFF MEMORY E will turn all selections ON PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT all OFF No zones trigger AUX2 NOTES OE will turn all selections OFF MEMORY E will turn all selections ON PROGRAMMING SIREN OUTPUT ZONES Selects the zones to trigger the Siren output PROGRAMMING SEQUENCE P57E Zone No E toggles the options ON and OFF P57E Zone No E OFF The zone will not trigger the Siren output P57E Zone No E ON The zone will trigger the Siren output AUX1 OUTPUT ZONES Selects the zones to trigger the AUX1 output AUX1 output is Pin1 on the J3 header on the main board PROGRAMMING SEQUENCE P58E Zone No E toggles the options ON and OFF P58E Zone No E OFF The zone will not trigger the AUX1 output P58E Zone No E ON The zone will trigger the AUX1 output AUX2 OUTPUT ZONES Selects the z
88. nd OFF P88E 5E OFF No Forced opening Reports P88E 5E ON Forced opening Reports enabled DELAY CLOSING REPORT If selected ON Closing reports if enabled are sent at the end of Exit Time Normally Closing reports are sent immediately on Arming PROGRAMMING SEQUENCE P88E 6E toggles the option ON and OFF P88E 6E OFF Closing Reports sent on Arming P88E 6E ON Closing Reports sent at end of Exit Time MANUAL EXCLUDE REPORT Enables Manual Exclude Reports for Zones 1 8 Exclude Reports for 24hr zones are sent on exiting EXCLUDE mode PROGRAMMING SEQUENCE P88E 7E toggles the option ON and OFF P88E 7E OFF No Manual Exclude Reports P88E 7E ON Manual Exclude Reports enabled AUTO EXCLUDE REPORT Enables Auto Exclude Reports for Zones 1 8 Zones not sealed on Arming will be reported as Auto Excluded PROGRAMMING SEQUENCE P88E 8E toggles the option ON and OFF P88E 8E OFF No Auto Exclude Reports P88E 8E ON Auto Exclude Reports enabled NESS D8 V4 CONTROL PANEL INSTALLER MANUAL PROGRAMMING ee o 5 S oo D de OPTION No DESCRIPTION P89E Miscellaneous Reporting options CC ILI ON Factory default setting ENABLE TEST CALLS This option enables the reporting of dialler test calls to the Central station P89E 1E PROGRAMMING SEQUENCE P89E 1E toggles the option ON and OFF PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Test Calls enabled P89E 1E OFF No Test Calls P89E 1E
89. ne or mobile phone The last digit of the Installer Remote by PC Account number and the zone alarm are sent in Audible DTMF format The message is repeated for 45 seconds or until kissed off by the receiving FACTORY DEFAULT OFF telephone s PROGRAMMING SEQUENCE P86E 3E turns the option ON Only one option in the range P86E 1E 6E is allowed to be ON P86E 3E ON Audible DTMF format enabled AUDIBLE PULSE FORMAT P86E 4E PROGRAM MODE LEVEL For Audible Monitoring to any telephone or mobile phone The last digit of the Installer Remote by PC Account number and the zone alarm are sent in Audible PULSE format The message is repeated for 45 seconds or until kissed off by the receiving FACTORY DEFAULT OFF telephone NOTES TEE PROGRAMMING SEQUENCE P86E 4E turns the option ON Only one option in the range P86E 1E 6E is allowed to be ON This is the best option to select for Audible Monitoring P86E 4E ON Audible PULSE format enabled NESS D8 V4 CONTROL PANEL INSTALLER MANUAL n PROGRAMMING P86E 5E CONTACT ID AUDIBLE DTMF FORMAT PROGRAM MODE LEVEL For simultaneous Central Station and Audible Monitoring Remote BY EE The alarm message will be sent to the Central Station on the Primary telephone FACTORY DEFAULT number and then in audible DTMF format to the Follow Me telephone number OFF NOTES PROGRAMMING SEQUENCE Only one option in the range P86E BE turns the option ON FOR
90. ny program mode 90 LCD KEYPAD T Backlit LCD H1 2 345 6 7 9 10 11 12 13 14 15 1 V 9 5 M 1 READY ARMED 2 ALARM TAMPE MEMORY icon display PANIC buttons 135mm ARM button MONITOR MONITOR button EXCLUDE button MEMORY button PROGRAM button ENTER button Protective flap not shown The Not Ready light is on when the panel is not ready to Arm ie a zone is unsealed there may still be movement in the premises or a door or window left open LCD KEYPAD ZONES 1 8 Zone is sealed STATUS Zone is unsealed XS FLASHING Zone alarm da 3 beeps READY Error or phone line fault Zone is unsealed or Power fault or System is Armed Ready to Arm JT L 1 long beep ARMED Mains Power is off or Panel Battery is low RMED Disarmed Monitor Mode Armed AREA 1 LED Keypad J 11071 10 beeps O ARM2 9 a RM2 Disarmed Armed AREA 2 Gre Disarmed Monitor Mode MAINS NS Normal Mains Power is off BATTERY TERY Normal The panel s backup battery is low MEMORY ALARM MEMORY Normal Memory Mode selected New alarms in memory EXCLUDE EXCLUDE Normal Zones are excluded TAMPER TAMPER Nor
91. oggles the option ON and OFF P89E OFF No Line Fault output P89E GE ON Line Fault to AUX2 enabled NESS D8 V4 CONTROL PANEL INSTALLER MANUAL PROGRAMMING c OPTION No DESCRIPTION P90E Upload Download options EENEENM ON Factory default setting ENNIO XI REMOTE ACCESS When selected On this option allows the panel to be remotely upload downloaded by a remote computer or controlled by a remote telephone PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT When the option is Off the panel will not answer incoming telephone calls OFF No Remote Access preventing any type of remote access NOTES P91E Required Rings P90E 1E toggles the option ON and OFF P90E 1E OFF No Remote Access P90E 1E ON Remote Access enabled ENNIO DIRECT CONNECT This allows a direct connection to be used between the D8 telephone output and an on site computer with modem A special NESS adapter is required PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT when using this connection OFF No Direct Connect Direct Connect simulates a telephone line ring and makes the D8 connect NOTES immediately to the telephone line Remote Access must also be enabled RELATED OPTIONS PROGRAMMING SEQUENCE PQOE 1E Enable Upload Download P90E 2E toggles the option ON and OFF P9OE 2E OFF No Direct Connect 9 2E ON Direct Connect enabled 6 UU UMP MODEM d E D8 Control Panel r2 605 room Plug COMPUTER U z
92. ones to trigger the AUX2 output AUX2 output is Pin2 on the J3 header on the main board PROGRAMMING SEQUENCE P59E Zone No E toggles the options ON and OFF P59E Zone No E OFF The zone will not trigger the AUX2 output P59E Zone No E ON The zone will trigger the AUX2 output NESS D8 V4 CONTROL PANEL INSTALLER MANUAL PROGRAMMING Q OPTION No DESCRIPTION 1E 2E 3E 4E 5E 6 Peo varousoptions Ton on ON Factory default setting ENTRY BEEPS The sonalert will beep during Entry Delay PROGRAMMING SEQUENCE P60E toggles the option ON and OFF PROGRAM MODE LEVEL Installer Remote by PC P60E 1E OFF Entry Beeps OFF P6OE 1 ON Entry Beeps ON FACTORY DEFAULT Entry Beeps ON NOTES KEYSWITCH MONITOR MODE ARMING An externally fitted normally open momentary Keyswitch can be used to Arm PROGRAM MODE LEVEL Disarm or change the D8 to Monitor mode The keyswitch is wired to zone 8 zone 8 is then no longer available as a normal alarm input but IS still available for use as a Radio Zone Installer Remote by PC FACTORY DEFAULT No keyswitch enabled o_o NOTES e The keyswitch always Arms Area only The keyswitch always Disarms Area1 and Area2 P60E 3E is ON P60E 2E is ON P60E 3E is ON Momentary short circuit across resistor to toggle panel modes Open circuit resistor to trigger keyswitch 2E is ON panic Multiple keyswitches can be used Wire PROGRAMMI
93. puts are separately fused with Automatic Reset Fuses Day Mode and Door Chime feature 30 Event Memory Supports 8 Radio Devices Radio PIRs Radio Reeds etc Supports 14 Radio Keys All inputs and outputs are heavily protected against lightning and high voltage supply transients An earth terminal is provided for extra protection 15 User Codes Arm only codes can be pro grammed Programmable Inputs to activate selectable Outputs Designed utilising the latest SMD Technology Forced Arming Feature Simple to Program and Use INTRODUCTION The NESS D8 is a wholly Australian Designed and Manufactured product from Ness Security Products Australia s largest manufacturer of quality electronic security products Ness Security Products Pty Ltd is a Quality Accredited Company to ISO 9001 This version of the D8 introduces a number of new features including Radio PIR Supervision Ness LCD Keypad and numerous other innovations D8 Version 4 ENHANCEMENTS OVER Versions 3 x RADIO Radio supervision Radio supervision can be used with NESS radio detectors that transmit periodic supervision signals Options added to either Toggle or Pulse Aux1 with the Radio Panic key Option to have quieter siren chirps when arming disarming with key switch or radio keys ARMING Arm only codes Keypad codes can now be made to ARM ONLY this does not apply to Radio key codes Option for siren warning burst when arming
94. r wiring detail gt 12 DC Power for detectors etc NESS LED Keypad NESS LCD Keypad 100 192 100 667 CLK COM Maximum HN 3 keypads EARTH White 17V AC Red amp Black Up to 2 x Ness 12V Siren 100 172 OR 3 x Top Hat Screamer 100 238 Up to 2 x Strobe Light NOI 300 Up to 2 x Horn Speaker 8 Ohm NOI 110 Ness 17V AC Plug Pack 840 029 Australia only NESS D8 V4 CONTROL PANEL INSTALLER MANUAL C WIRING EXAMPLES NESS QUANTUM DETECTORS 4 WIRE CONNECTION ANY N C DEVICE NESS D8 NESS D8 CONTROL CONTROL PANEL PANEL ov O H12V 12 QD Zone 1 8 262 REED SWITCH N C contacts TAMP TANP C C NESS QUANTUM DETECTOR all models NESS QUANTUM DETECTORS 6 WIRE CONNECTION ANY N O DEVICE NESS D8 NESS D8 CONTROL CONTROL PANEL PANEL ov ov 42V 12V Zone 1 8 Zone 1 8 me E PANIC BUTTON N O contacts NESS QUANTUM DETECTOR all models EXTERNAL INTERNAL 12V INTERNAL SIREN 100 172 or NOI230 NOI240 100 238 TAMPER SWITCH Swig20 666960009 96696969009 NOTE Ness Panel amp Noise KITS are supplied with the Ness Internal Horn Speaker 100 171 This must
95. s reset whichever comes first A maximum of 3 x 12V piezo Sirens Ness Part No NOI240 NOI 230 100 238 or 2 X Ness Piezo Part No 100 172 can be connected to this output The output is protected by an Automatic Reset fuse J3 HEADER AUX1 This output is an open collector switch negative which can supply a maximum of 100mA Zone alarms may be selected to trigger this output by option P58E AUX2 This output is an open collector switch negative which can supply a maximum of 100mA Zone alarms may be selected to trigger this output by option P59E ARM1 This output is an open collector switch negative which can supply a maximum of 100mA This output is turned on when Area 1 is armed ARN2 This output is an open collector switch negative which can supply a maximum of 100mA This output is turned on when Area 2 is armed NESS D8 V4 CONTROL PANEL INSTALLER MANUAL 2 L V S KEYPAD INSTALLATION Unclip the top half of the keypad housing by pushing the top clips down with a small screwdriver and pulling the housing forward Screw the base of the keypad housing to the wall using the 4 mounting holes provided Bring the 4 connecting wires to the terminal block on the PCB on the rear of the keypad housing Connect the wires to the screw terminals as per the wiring diagram shown in this manual Clip the top half onto the base by first engaging the bottom clips and swin
96. stores panel program options to their factory default values Defaults the options POOE P26E to P93E P99E This includes all options except User Codes Radio Codes amp Radio Devices PROGRAMMING SEQUENCE P97E Restores Factory Defaults CLEAR USER CODES This option clears all User codes and Radio Codes Radio Keys and restores factory default codes PO9E P10E are defaulted Radio Codes assignment P11E P25E are defaulted User Codes 1 15 PROGRAMMING SEQUENCE P98E Clears User Codes PROGRAM THE INSTALLER CODE Programs the installer code This code can be 3 to 6 digits long Factory default installer code is 000000 PROGRAMMING SEQUENCE P99E Enter new code E Enter new code again E Unlike User Codes the installer code is not displayed when programming NESS D8 V4 CONTROL PANEL INSTALLER MANUAL NOTES The Ness Radio Interface is normally installed inside the control panel box n cases where radio reception needs to be improved the Radio Interface can be installed up to 50 metres away from the control panel Use 14 0 20 cable If the Radio Interface must be installed inside a metal enclosure the antenna wire should protrude outside the enclosure For best performance the antenna wire should not be kept straight and not coiled shortened or extended NOTES Signal strength of Radio Keys can be tested in USER PROGRAM Mode or INSTALLER PROGRAM Mode Signal strength of a
97. swer dial Telephone No 2 Continue alternating until successful P87E 1E ON Split Dial Dial Telephone No 1 for half of the call attempts If unsuccessful dial Telephone No 2 for the last half of call attempts CHECK FOR DIAL TONE The dialler normally dials only if a dial tone is detected The dialler can be forced to dial without a dial tone Allows use on PABXs with non standard dial tones PROGRAMMING SEQUENCE P87E 2E toggles the option ON and OFF P77E 2E OFF Dial without dial tone P87E 2E ON Dial only with dial tone NUMBER OF DIALLING ATTEMPTS Sets the number of dialling attempts when sending reports ON allows a maximum of 4 dial attempts before a 5 minute sleep and 4 more retries if unsuccessful OFF sets a maximum 10 dial attempts before a 5 minute sleep and 10 more re tries if unsuccessful If all attempts fail the dialler waits for the next trigger event The previously unsuccessful report will be included in the new message PROGRAMMING SEQUENCE P87E 4E toggles the option ON and OFF P77E 4E OFF Maximum 10 dialling attempts P87E 4E ON Maximum 4 dialling attempts NESS D8 V4 CONTROL PANEL INSTALLER MANUAL em EX 8 B amp 265 c a PROGRAMMING 2E 3E 4E 5E 6E OPTION No DESCRIPTION 1E P88E Open Close reporting options onl ON Factory default setting AREA1 OPEN CLOSE REPORTS Enables or disables sending of AREA1 Open Close reports P88E 1E The User ID of the
98. t Exclude mode ALARM MEMORY User Code Or User Code Press repeatedly to display the last press repeatedly to display 30 events the last 30 events To exit Memory mode E To exit Memory mode NESS D8 V4 CONTROL PANEL INSTALLER MANUAL QUICK START 1 LOCAL SYSTEM Quick Start 1 shows you how to change User Code 1 the Master Code By default the dialler is disabled until programmed QUICK START 2 AUDIBLE MONITORING Quick Start 2 shows you how to change User Code 1 the Master Code enable Audible Monitoring and program 1 telephone number This will enable the dialler to report alarms to any telephone including mobile phones QUICK START 3 CENTRAL STATION MONITORING Quick Start 3 shows you how to change User Code 1 the Master Code enable Central Station Monitoring and program one telephone number This will enable the dialler to report alarms to a Central Station STEP N STEP PROGRAMMING QUICK START PROGRAMMING Use one of these programming summaries for fast setup of your D8 as a Local Audible Monitored or Central Station Monitored system The control panel will be ready for use immediately QUICK START 1 step by step KEY STROKES DESCRIPTION Enter User Program Mode COMMENT Program Light is ON Selects the option for User Code 1 The existing code is displayed by the keypad lights followed by 3 beeps
99. ted from both programmed and non programmed radio devices NESS RADIO INTERFACE Part No 100 200 NESS D8 CONTROL PANEL Ini RED 12V gt WHITE DATA BLUE RSSI 9 BLACK ov 2 SIGNAL STRENGTH The Signal Strength test can be used to test the radio signal from any Ness radio device The strength of the radio signal received is displayed on the zone lights 1 8 and beeped by the keypad The higher the number displayed and beeped the stronger the signal received TEST SEQUENCE Enter the option for the radio device to be tested For Radio Keys options P12E P25E For all other radio devices options PO1E PO8E Press 3E Trigger the radio device One of zone lights 1 8 will turn ON to indicate the signal strength from the transmitter The Signal Strength display remains on until another command is entered To clear the display and re test the transmitter simply press again or 4E to test any other transmitter NESS D8 V4 CONTROL PANEL INSTALLER MANUAL ri NESS RADIO NESS RADIO DEVICES Signal types transmitted SIGNAL RADIO KEY RADIO KEY RADIO RADIO SMOKE PENDANT 3 BUTTON RADIO PIR REED SWITCH DETECTOR TYPE 100 665 100 664 100 663 100 662 100 203 ALARM ON button ON button RESTORAL OFF button LOW BATT yes yes TAMPER SUPERVISION RADIO DEVICES OPERATION ALARM Any Ness Radio Device can operate on any zone 1 8 as programmed by PO1E P
100. thorised up download the panel will dial the callback telephone number to commence an up download session Up download without callback is allowed by turning off option P9OE 8E PROGRAMMING SEQUENCE P81E existing telephone number is displayed ENTER NEW TELEPHONE No E new Telephone No 4 is displayed EXAMPLE To program Telephone No 4 to be 02 8825 1234 P70E0288251234E FOLLOW ME TELEPHONE NUMBER The Follow Me telephone number is only used in Audible Dialling mode P86E 3E 4E 5E or 6E are on The Follow Me telephone number can be programmed in User Program Mode If the Follow Me number is programmed then the primary amp secondary numbers are ignored PROGRAMMING SEQUENCE POOE existing telephone number is displayed ENTER NEW TELEPHONE No E new telephone number is displayed EXAMPLE To program Telephone No 4 to be 02 8825 1234 P70E0288251234E NESS D8 V4 CONTROL PANEL INSTALLER MANUAL P74E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All zones report Alarms NOTES OE will turn all selections OFF MEMORY E will turn all selections ON P76E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All zones report Restorals NOTES OE will turn all selections OFF MEMORY E will turn all selections ON RELATED OPTIONS P82E 1E Send Restoral immediately P82E 2E Send Restoral after siren time P82E 3E Send Restoral on Disarm amp seal P82E 4E Send Restoral on Disarm
101. ways on P60E 7E ON Display will blank after 4 minutes DELAY ARM1 amp ARM2 OUTPUTS The output ARM1 turns on when Area 1 is armed The output ARM turns on when Area 2 is armed These outputs can be programmed to turn on instantly or at the end of Exit Time ARM1 amp ARM2 output s are Pins 3 amp 4 on the J3 header on the main board PROGRAMMING SEQUENCE P60E 8E toggles the option ON and OFF P60E 8E OFF ARM1 amp ARM outputs turn on instantly P60E 8E ON ARM1 amp ARM2 outputs turn on at end of Exit Time NESS D8 V4 CONTROL PANEL INSTALLER MANUAL PROGRAMMING 1E 2E 3E 4E 5E 6E 7E 8E OPTION No DESCRIPTION Pere Temper amp Parc alarms mapping ON ON oN oN ON On ON ON ON Factory default setting TAMPER ALARM OUTPUT MAPPING This option selects which outputs will trigger when a Tamper Alarm occurs PROGRAMMING SEQUENCE P61E 1E 4E toggles the options ON and OFF PROGRAM MODE LEVEL Installer Remote by PC P61E 1E Tamper Alarm to Reset output FACTORY DEFAULT 1E 4E ON Tamper alarm triggers all outputs NOTES P61E 2E Tamper Alarm to Strobe output oA Tamper Alarm can be caused by the P61E 3E Tamper Alarm to Keypad Sonalert output TAMP input or by removing the the P61E 4E Tamper Alarm to Siren output KEYPAD PANIC ALARM OUTPUT MAPPING This option selects which outputs will trigger when a Keypad Panic alarm link P61E 5E 8E PROGRAM MODE LEVEL Installer Remote by PC occurs
102. will commence transmission of the next message The D8 should continue to do this until all alarm messages are transmitted and Kissed off ACKNOWLEDGE TONE The person receiving the call can then acknowledge the alarm by pressing the key on their telephone Press the s key for at least 2 seconds during pauses in the audible message If the alarm is not acknowledged the keypad s LINE light will flash continuously until the panel is next Armed ALARM EVENTS SENT The Reporting Format Table identifies the alarm events which can be programmed to be sent in Audible Format Open Close reports Restorals and Exclusions Isolates are NOT sent in Audible Format even if selected ON NESS D8 V4 CONTROL PANEL INSTALLER MANUAL AUDIBLE FEEDBACK 4d 3 BEEPS The User Code is valid Successful Arming or Disarming An Auxiliary output has been turned ON J 1 LONG BEEP D8 is already Armed Invalid code Try again SHORT BEEP An Auxiliary output has been turned OFF SUMMARY OF TELEPHONE COMMANDS Prepare to receive commands Arm Areas st Disarm Areas st Turn Aux 1 Output ON or OFF Turn Aux 2 Output ON or OFF st Finished hang up 8 8 2 9 OPERATING THE D8 BY TELEPHONE The D8 will allow a user to call in to the panel using a standard DTMF telephone and remotely Arm or Disarm all areas and also turn on or off Aux 1 and Aux 2 To maintain
103. with radio key and a zone is unsealed Warning beeps timing extended by changing to Entry Delay 2 timer Monitor mode outputs are now selectable for both the 2 second monitor mode and full monitor mode The outputs for Area 1 and Area 2 can now be made to pulse on for 2 seconds This makes them useful as Smoke Detector Reset outputs by adding an external relay DIALLER Aux 2 output option for telephone line fail Dialler sends a CANCEL report if there has been an alarm in full monitor mode Dialler Listen In has been added via the Siren output The Miscellaneous Alarm reporting options have been increased to include reports such as Mains Fail Battery Fail radio tamper reports and others now selectable Audible Format is now more flexible in alarm reports Mains and Battery fail reports can now be sent when using the Audible format if required Closing reports can be delayed until end of exit time Manual and Auto Exclude reports can be disabled UP DOWNLOAD CallBack in Normal Mode and User Program mode is now optional to allow up download without having a fixed callback telephone number The D8 Up Download Software is completely new and is compatible with Windows 9x The user interface and presentation is also completely different HARDWARE An option to select 3k3 EOL resistors for Zones Default is 2k2 A Tamper lead assembly has been provided to connect the internal tamper switch to the Tamp header
104. xcept 24hr zones are inactive during the Exit Delay time The Exit Delay Time setting is from 1 to 99 seconds PROGRAMMING SEQUENCE P28E existing time is displayed ENTER NEW TIME E new time is displayed EXAMPLE To program Exit Delay to be 85 seconds P28E 85E SIREN RESET TIME The Siren Reset Time sets the duration of the Siren and Reset outputs The Siren Reset Time setting is from 1 to 99 minutes PROGRAMMING SEQUENCE P29E existing time is displayed ENTER NEW TIME E new time is displayed EXAMPLE To program Siren Time to be 4 minutes P29E 4E NESS D8 V4 CONTROL PANEL INSTALLER MANUAL P30E P38E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT Normal sensitivity P30E all zones ON NOTES Sensitivity can be individually programmed for each zone Zones are allocated to one sensitivity level at any one time Turning a zone ON in a sensitivity level turns the zone OFF in any other sensitivity level To revert zone sensitivity back to Normal Turn the required zone s ON at Option 30 Avoid using P31 and P38 sensitivity they are provided as a guide to the upper and lower limits USING NESSENSORS Nessensors are sensitive to high frequen cies and insensitive to low frequencies Therefore it is not necessary to apply much force to the protected structure rather a very rapid succession of blows The sensitivity has been correctly ad justed when a single blow