1. ioa sat FIG 8 Extend both ends of the exhaust hose by few inches Connect hose to the back of unit by turning clockwise do not over tighten Connect adapter piece to hose by turning clockwise with opening end facing you Determine how many sections of the slider kit your window requires Place slider kit inside the window frame and adjust height accordingly Once set insert the small screw through side opening to secure Align and insert adapter piece to opening on window kit Slide window close against the window kit The best distance between the machine and window or wall is 31 39 inches Mounting of the exhaust pipe e Useonly the hose provided and clip exhaust hose to the back of the air conditioner FIG 11 e Avoid kinks and bends in the exhaust hose If expelled air is not exhausted smoothly it will build up in the hose and lead to unit overheating and X shutting down Refer to Fig 11 amp 12 for correct FIG 12 position e he hose may be extended from 11 to 59 But for maximum efficiency use the shortest length FIG 13 possible WARNING The length of the exhaust pipe is specially designed according to the specification of this product Do not replace or prolong it with your own private hose as this tt could cause the unit to malfunction Carbon Filter Installation 2 O 2 a D fa 2 ae 2 D mum u D 2 O D c goo UT ML DLL VHT PT 2 R
2. n PORTABLE AIR CONDITIONER WITH HEATER WA 9061H 9 000 BTU WA 1061H 10 000BTU Jx Read and retain these instructions for future reference SPECIFICATION WA 9061H WA 1061H 9000 BTU hr 10000 BTU hr Cooling capecty capacity 2637 W 2930 W Heati 8500 BTU hr 9500 BTU hr Mane caper 2491 watts 2783 watts consumption Cooling 960W 8 29 A 1070W 8 7 A Power Ampere consumption Heating 840W 7 75 A 950W 8 18 A Air volume max speed 375m h 375m h Humidity removal capacity 1 L hr 1 L hr Power supply 110 120V 50Hz 1phase Compressor rotary DEIN Fan speed o 00000000 2 O Cooling 64 90F 18 32 Heating 45 77 F 7 25 Operating temperature TEMPA AUIE 45 95F 5 x 59 in Net Weight 47 4 lbs 55 12 Ibs 12W x 15D x 29 61H in Data may vary for technical reasons for greater precision please refer to the rating label located on the back of the unit Thermostat NOTE 1 Measuring condition for above is Cooling DB 95 f WB 75 Heating DB 68 f WB 59 2 Current amp Fuse F2L250V or T2L250V BEFORE USE GENERAL SAFETY e Only use in the upright position on a flat level surface and at least 14in from any walls or X objects fig 1 amp 4 e Do not place any objects on the unit or block the v FIG 1 air inlet outlet fig 2 e Closely supervise children and pets when unit is X in use 6 ELECTRICAL SAFETY e For indoor household use only e Switch
3. of season storage e Drain water from the unit e Operate the unit in FAN mode for a few hours to 2E thoroughly dry the inside a e Clean or change the filters BN Nord e Unplug and store the power cord as shown e Replace in the original carton or cover for storage um Fi BB TROUBLE SHOOTING Is the air conditioner plugged in The air conditioner does not Is there a power failure run Is the Water Full indicator flashing Is the room temperature below the set temperature Is there direct sunshine Please close curtain The machine seems to do Too many windows or doors open little Too many people in the room Is there something in the room producing lots of heat Is the filter dusty contaminated Is the air intake or output blocked up Is the room temperature below set temperature Too nois s the machine positioned unevenly creating vibration y Is the floor underneath the machine uneven tis possible the overheat protection is on Just wait for The compressor doesn t run the temperature to drop Xx Never try to repair or dismantle the unit yourself The machine seems to do nothing 11 fel Your Guarantee If this product is found to be faulty as a result of faulty materials or workmanship within one year from date of purchase it will be repaired free of charge This guarantee is subject to the following terms Sunpentown must be notified of the fault Proof of purchase must be present
4. FF button again Setting mode function Press MODE button to select desired working mode AUTO COOL FAN or HEAT The indicator of selected mode will illuminate Setting temperature 1 2 Press Temperature up or Temperature down button to set desired temperature The display window will show the set temperature as the UP or DOWN buttons are pressed Once the buttons are release display will revert to show the ambient temperature The pre set temperature is 75 24 for cooling an d 68 t 20 C for heating 7 Setting fan speed j Press SPEED button to choose the desired fan speed high or low The corresponding indicator HI or LOW will illuminate If the unit is operating in AUTO mode the SPEED button is invalid Unit will automatically choose the fan speed based on the ambient temperature Setting timer 1 If unit is in operation pressing the TIMER button will set the operating hours from 1 to 12 hours Once the set time has been reached unit will turn off automatically Timer indicator will illuminate Display window shows the hour s as TIMER button is pressed If unit is off pressing the TIMER button will pre set the time for the unit to come on For example if you set the timer to 2 the unit will begin operating after 2 hours Sleep function 1 When selected in COOL mode unit will increase the set temperature by 2f 1 after the first hour and another 2f 1 C after the second hour then keeps at t
5. ed to Sunpentown s nominated representative The warranty will be void if the product if modified misused or repaired by an unauthorized person The warranty after repair will not be extended beyond the original one year period All replacement parts will be new or reconditioned Parts which are replaced become the property of Sunpentown The warranty applies for the use of the product in the USA only What is NOT COVERED Warranty does not include freight charges Incidental or consequential damage caused by possible defects with this product Damage to product caused by improper power supply voltage accident fire floods or acts of nature Failure of product resulting from unauthorized modifications to the product Improper installation or failure to perform the necessary maintenance This GUARANTEE is in addition to your Statutory Rights SUNPENTOWN INTERNATIONAL INC 14625 Clark Ave City of Industry CA 91745 Tel 800 330 0388 service sunpentown com www sunpentown com 12
6. emove the filter fixer from the filter frame 3 Remove active carbon filter from plastic bag EER EBBAREE 4 Insert active carbon filter to filter frame carbon filter is now held in between the filter 5 Replace filter fixer to frame The active frame and filter fixer 11119 13 TH nmm LLIM LIS EG 6 Replace filter frame to unit Wr TTT yi TT N OPERATION Control panel oc Or In 2m SE qn cs pi VY ws O AUTO COOL FAN HEAT FULL WATER MODE TIMER wv 1 2 5 O FIG 15 Mode function select button 10 Temperature down button Timer button 11 ON OFF power button Water Full indicator 12 Temperature up button Sleep button 13 Timer operation indicator Fan speed button 14 Compressor operation indicator Low fan speed indicator 15 Heat mode indicator High fan speed indicator 16 Fan mode indicator Receiver for remote control 17 Cooling mode indicator Sleep operation indicator 18 Auto mode indicator Turning ON OFF TL Press ON OFF button and unit will start automatically If ambient temperature is Above 74 239 the unit will work in Cool mode Above 68f 20T but below or equal to 74 23 C th e unit will work in Fan mode Below 68 F 20 the unit will work in Heat mode Indicators of the functions in progress will illuminate NOTE The display window shows ambient room temperature from 32 122 F 0 50 C To turn the unit off press ON O
7. hat temper ature When selected in HEAT mode unit will decrease the set temperature by 2f 1 after the first hour and another 21 1 C after the second hour then keeps at that temper ature In SLEEP mode fan speed will be kept at LOW Pressing the SLEEP button again will revert set temperature and fan speed back to pre selected settings The unit will shut down automatically after operating in SLEEP mode for 12 hours continuously NOTE SLEEP function is not available in AUTO or FAN mode HEAT mode 1 When HEAT mode is selected the ambient warm air will be recycled and utilized to heat the area where it is required The Exhaust Pipe must be fitted properly to exhaust the cold air outdoors Continuous drain is mandatory when unit operates in heat mode The working temperature range for heating function is 45 77 F 7 25 C If ambient temperature is outside this range the unit may not work properly Remote control OG All functions can also be performed with the supplied remote control The remote control requires two 2 AAA batteries Fig 16 Directing air flow Manually adjust the louvers left amp right or up amp down to direct air flow FIG 17 NOTICE To prolong the life of the compressor after powering off the unit please wait at least 3 minutes before turning it back on When operating in COOL mode the cooling system will switch off when ambient temperature falls below set temperature The fan
8. however will continue to run Once ambient temperature rises above the selected level cooling will resume When operating in HEAT mode heating will switch off when ambient temperature is higher than set temperature The fan however will continue to run Once ambient temperature drops below the selected level heating will resume This machine is equipped with ANTI FROST function When unit is operating in low temperature surroundings the heating function may be paused at times to defrost When this occurs just wait for heating to resume DRAINAGE During the cooling process some water will be extracted from the air into the unit If the reservoir is full both of the compressor cooling and motor fan will stop and unit will emit a Buzz press any button to stop the buzz the Water Full indicator will also be flashing Before cooling can resume empty the water tank 1 Turn off the air conditioner and avoid moving it when full 2 Position a container a water tray for example underneath the drain spout 3 Remove the drain knob amp rubber plug and allow water to drain out 4 When the container is almost full replace the rubber plug and empty the water tray Repeat until the unit is emptied 5 Replace rubber plug and tighten drain knob firmly Drain spout a 6 Switch on the unit the Water Full indicator should no Rubber plug Drain knob longer be flashing FIG 18 Continuous drainage if you wish to opera
9. off and unplug when not in use FIG 2 e Do not use in humid or wet environments fig 3 e Do not pull the UNIT by the cord e IF THE SUPPLY CORD IS DAMAGED TO AVOID HAZARD IT MUST BE REPLACED BY AN ELECTRICIAN OR SIMILARLY QUALIFIED ete PERSON His FOR MAXIMUM EFFICENCY X e Use the unit in the recommended room size J FIG 3 e Locate the unit where furniture cannot obstruct the airflow e Close doors and windows e Keep curtains or blinds closed during the sunniest part of the day e Keep filters clean e Set unit to maximum cooling on high initially and once room has reached the desired conditions reduce temperature and fan speed settings e t is recommended to turn on the air conditioner when ambient temperature reaches 75f Do not wait until the room is excessively hot Display window Control panel Air outlet Carrying handle Caster P oreet quc Accessories 14 13 Exhaust hose 14 Slider kit adapter connects exhaust hose to slider kit 15 Plastic slider kit piece 1 of 2 Back FIG 5 Cord storage Air filter Air inlet Exhaust air outlet Air inlet Water stopper drainage o Dom O 49 FIG 7 16 Plastic slider kit piece 2 of 2 17 Drain tube 18 Active carbon filter 19 Remote INSTALLATION The unit is a portable air conditioner that may be moved from room to room 1 Installing the plastic slider kit Window kit
10. te the unit without the need to empty the water tank e Remove the drain knob and rubber plug and retain EHE for future use EPA Pa C e Connect the supplied drain tube to the drain spout O e Drai t as shown and locate the other end into a drain ran spou l Rubber plug Drain knob e Note the drainage is gravity pulled the drain tube must not have any incline FIG 19 e The drain tube can be extended by adding an SS extension tube with a suitable connector A me O Drain tube FIG 20 Note 2 1 e Drain tube must be paralleled or below outlet level Originally M uw SS supplied tube e Flashing Water Full indicator will not function in T F continuous drainage W e To extend the water tube connect with another FIG 21 tube OD 18mm Extension tube OD 18 mm 10 MAINTENANCE Always unplug the air conditioner from power source before cleaning Clean regularly to maximize the efficiency of the air conditioner Cleaning the housing Use a soft damp cloth to wipe the body clean Never use aggressive chemicals gasoline detergents chemically treated cloths or other cleansing solutions These products may blemish the cabinet Cleaning the filter Use a vacuum cleaner or tap the filter lightly to first remove any loose particles then rinse thoroughly under running water no hotter than 104 F 40 Dry thoroughly before replacing Never operate the unit without the filters End
Download Pdf Manuals
Related Search
Related Contents
Infinity REF5032CF car speaker Samsung NS244HXBA User Manual (XP) こちら - テック I/O Magic TeraBank I1000HD35 User's Manual Wiley Photoshop Elements 6 For Dummies File 安全なライディング 6142.116-Entfeuchter 2120--DH-00 COVER.indd - Migros Benutzerhandbuch Business English - Deutsch Télécharger le document - Ville de Saint-Martin-de-Crau Copyright © All rights reserved.