Home
User Manual
Contents
1. Equipment not complying to IEC 60601 must be kept outside the patient environment as defined in the standard as at least 1 5 meters from the patient or the patient support Any person who connects external equipment to signal input signal output or other connectors has formed a system and is therefore responsible for the system to comply with the requirements of IEC 60601 1 1 If in doubt speak with a qualified technician Safety tips Never open the display case even when the power is off Dangerous voltage inside may cause electric shock or death To avoid damage to the display use the grounded power supply and video cable supplied by NDSsi or use certified replacements Be sure the display is electrically grounded You must connect the third grounding pin on the US power cord to a grounded outlet The European power cord does not have a third grounding pin but it must be plugged into a grounded outlet If you cannot insert the plug into the outlet you plan to use have a licensed electrician replace the outlet with a properly grounded outlet If the power cord connects directly into the computer make sure the computer is grounded Keep the display dry if it is part of a surgical system The display lacks protection against liquids or spills e In locations where 240V outlets are used connect the Dome Sx display only to a center tapped 240V single phase supply for Canada and the United States GROUND
2. control brightness contrast Display identification USB hub on stand USB uplink on display Display status Landscape orientation Portrait orientation VGA XGA Display size without stand Display weight without stand Display weight with stand Mounting options Adapter 12 Dome Sx Display Specification AMLCD active matrix liquid crystal display 540 mm 21 3 in 1536 x 2048 pixels portrait 2048 x 1536 pixels landscape 0 2115 mm 120 dpi LCR vertical stripe 433 2 x 324 9 mm 17 05 x 12 79 in 1024 shades of gray programmable gamma from palette of up to 3061 shades of gray 60 Hz 900 1 typical 650 1 minimum 1450 cd m typical 1150 cd m minimum 27 ms typical 170 85 horizontal vertical DVI Rev 1 0 digital dual channel connector DisplayPort Revision 1 1a connector DDC2B EDID read using DDC2B N A Universal Serial Bus Rev 2 0 1 uplink B port Dual stack tricolor LEDs on back of unit 2048 x 1536 10 bit per pixel 1536 x 2048 10 bit per pixel 640 x 480 to 1280 x 768 pixels displayed in portrait orientation 475 mm x 363 mm x 99 mm 18 6 in x 14 3 in x 3 9 in 6 6 kg 14 6 Ib typical 9 5 kg 20 9 Ib typical Desktop stand standard 100 mm VESA compliant mounting BridgePower BPM130S12F02 with power switch CAUTION Use only the adapter supplied with unit Power Supply CAUTION Use only the power adapter supplied with the Dome S3 display unit the Bridg
3. frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment under FCC rules Regulatory Compliance 25 Each Dome Sx display has one or more of the following certifications China China Compulsory Certification regulating safety and GB4943 2001 GB9254 2008 CB17625 1 2003 Class A Dome S3 Dome S3c and Dome 10 HAAR he ECSEARP CHR Ree FRE NS 7H Be oH RBFR ESM Fa ER RA MH Germany TUV Rheinland GM Mark for medical products eed ponpas Voluntary Control Council for Interference by information technology equipment sold in Japan Class A Dome S3 Dome S3c and Dome S10 CORES MAUBKESERREAERABABMS VCCI OR KES FIAZAGRRMHEETT ORE ERER CHEATS CBR UGRENEROFCEMHVES COMBA RICHES BEABRENSCEPHVETF Class B TORE MALLS ERMAAEMBBMS VCCI ORM CES lt TS ABMMRMERTH CORRS REMATHATSCL RBMELTUETH CORBP IV APCTLEY a gt AERE T AEHSL BEMBtNAROTCEPHVET BURR AARC TELURYRUEL TRA Korea G Korea Certification 26 Dome Sx Display NDSsi Dome Display Products Warranty and Service Terms and Condi
4. horizontal span mode Connector Plate Bits per pixel 10 24 30 DisplayPort only 10 8 Windows 7 10 Windows XP All Dome Sx displays have a DVI connector The Dome S3 and Dome S3c displays also have a DisplayPort connector Display Video Port Dome S3 DVI and DisplayPort Dome S3c DVI and DisplayPort Dome S10 DVI VCC 8 VCC 7 1 GND vcc6 2 GND OPO VCC 5 3 GND 4 GND VCC 6 ON 1 GND voos 202200 yota eS sen 18 Dome Sx Display DIN Connector Power Input 8 pin 12V 5 130 W 6 pin 24V 5 150 W 6 pin 24V 5 150 W Adapter BPC BPM130S12F02 with power switch BPC BPM150S24F05 with power switch BPC BPM150S24F05 with power switch 8 pin connector on Dome S3 display 6 pin connector on Dome S3c and Dome S10 displays LED Status Lights The two LEDs on the back panel of the Dome Sx displays provide information about the display LED A describes the digital link status between the display controller and the interface LED B describes the display panel status it shows any faults currently in the panel Power up sequence information from LED LEDA Action Sequence LEDB Action Sequence Dark Initial power on Flashing yellow Initial power on Blink yellow Self test Solid yellow Power on self test Dark One 1 second after Flashing green Self test pass power on LED A status information after initial power on LED Status Description Solid green Functional
5. is in default of payment until such payment has been made Warranty amp Service Terms 31 NDS Surgical Imaging LLC 5750 Hellyer Avenue as San Jose CA 95138 1000 USA SURGICAL IMAGING www ndssi com
6. link normal operation Flashing yellow Link working unrecognized sync information LED B status information after initial power on LED Status Description Solid green Functional system normal operation Flashing green Fault Solid yellow DDC power on 12V 24V power not detected Alternating green yellow POST failure NOTE A red LED or combination of red LEDs indicates a hardware or software fault Contact Dome Technical Support for assistance Technical Information 19 Troubleshooting Problem No image appears on the screen Conflict with driver version Unable to set the maximum or native resolution of the display 20 Dome Sx Display Possible Cause Computer is OFF Power cord is not securely connected Video cable connected incorrectly A previous version of the display driver is still installed on the computer system The installation CD contains a file older than the one currently on your system The function Hide all modes that this monitor cannot display is selected ona subdialog of the Windows Display Properties dialog A single link commodity graphics board is in use Solution Power on the machine Tighten power cord connection and turn on computer Make sure the first display of a dual headed system or the only display of a single headed system is connected to the primary port on the display controller Remove any existing display driver before you install a more recen
7. the sharp crisp images critical to softcopy medical viewing Unwanted analog display image artifacts are eliminated For display classification and use environmental guidelines safety precautions handling cleaning and storage tip and specifications see Technical Information on page 7 System Requirements e Windows 7 x86 or x64 or Windows XP Service Pack 3 x86 or x64 Intel or AMD multi core processor e PCI Express x16 lane slot 50 MB hard disk space e 512 MB RAM CD ROM drive e Power supply 350 watts or greater The Dome S10 display shown here for illustrative purposes Your display package may contain a Dome 3 Dome S3c or Dome S10 unit A Lr DC power adapter Power cord ee DVI cable DisplayPort cable Mini USB cable Quick reference NOTE DVI to DVI and DisplayPort cables ship in the Dome 3 and Dome S3c display packages DVI and mini USB cables ship in the Dome S10 display package 2 Dome Sx Display Display Components Review the following illustrations to identify controls and ports on the front and back panels of the Dome Sx displays Front sensor on Dome 3 Dome S3c MQSA button on Dome S10 The sensor on the front of the Dome 3 and Dome S3c displays allows you to run an auto conformance test without using a photometer The MQSA Mammography Quality Standards Act button lower right beneath display ID on the Dome S10 display facilitates any daily weekly or annual tests that y
8. 05 with power switch CAUTION Use only the adapter supplied with unit Power Supply CAUTION Use only the power adapter supplied with the Dome S10 display unit BridgePower BPM150S24F05 150W Category Power input requirements Power consumption Power output requirements Physical Reliability Characteristic item Display Backlight Environment Characteristic item EMI shielding Temperature Humidity Characteristic Item Specification Voltage selection Universal auto switching with medical approvals and PFC Voltage 100 240V AC Current 2 5 A Frequency 50 60 Hz Wattage 138 W maximum Voltage 24 V DC 5 Current 6 25 A 150 W Size 223 5 mm x 63 5 mm x 38 1 mm 8 8 in x 2 5 in x 1 5 in Weight 0 8 kg 1 8 Ib Specification MTBF gt 50 000 hours MTBF 50 000 hours to 50 brightness with backlight on continuously Specification No emission of low level radiation operating 5 C 35 C within specification storage 20 C 60 C operating 20 90 Relative Humidity noncondensing storage 5 90 Relative Humidity noncondensing Technical Information 17 Video Modes Resolutions expressed in pixels W x H Display Resolution Dome S3 1536 x 2048 2048 x 1536 Dome S3c 1536 x 2048 2048 x 1536 Dome S10 2x 2048 x 2560 Orientation Palette Portrait 32 bit Landscape Portrait True Color Landscape Portrait 32 bit non span mode 4096 x 2560 Landscape 32 bit
9. AROMETRIC PRESSURE Transport and storage 12 000 meters 39 400 feet maximum in unpressurized container RELATIVE HUMIDITY Transport and storage 5 to 90 noncondensing gt gt TEMPERATURE Transport and storage 20 to 60 C Intended use The Dome S series offers AMLCD units designed for viewing medical X ray images A Dome Sx display should not be used near patients and should be kept outside of 1 83 m perimeter and 2 29 m vertical Dome S3 and Dome S3c are intended for use in displaying and viewing medical images for review and analysis by trained medical practitioners Dome S10 is intended for use in displaying and viewing medical images for review and analysis by trained medical practitioners or for use in displaying and viewing radiographs of the breast for review and analysis by trained medical practitioners IMPORTANT Only the Dome S10 display can be used for review and analysis in mammography Do not use the Dome S3 or Dome S3c display in mammography review and analysis Federal law restricts this device to sale by or on the order of a medical practitioner Safety precautions External equipment intended for connection to signal input signal output or other connectors must comply with the relevant IEC standard EN IEC 60601 1 series for medical electrical equipment In addition all such combinations systems must comply with the standard IEC 60601 1 1 Safety requirements for medical electrical systems
10. DSsi products purchased through a distributor reseller or medical device manufacturer other than NDSsi each an Intermediary where such Intermediary provides direct warranty service to its end user customers in connection with such product DISCLAIMER This limited product warranty sets forth your sole and exclusive remedy and NDSsi s sole and exclusive liability under the Standard Limited Warranty described herein THERE ARE NO WARRANTIES EXPRESS OR IMPLIED WHICH EXTEND BEYOND THE DESCRIPTION CONTAINED HEREIN INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NONINFRINGEMENT Note that NDSsi sells its products through distributors resellers and other medical device manufacturers which prefer to provide their end user customers with direct warranty support Contact NDSsi Customer Care to determine if the product that you purchased is covered by this Standard Limited Warranty or whether you need to contact the Intermediary through which you purchased the product for warranty service 28 Dome Sx Display NDSSI S LIABILITY IS LIMITED TO THE COST OF REPAIR OR REPLACEMENT OF THE PRODUCT NDSSI SHALL NOT BE LIABLE FOR THE FOLLOWING 1 DAMAGE TO OTHER PROPERTY CAUSED BY ANY DEFECTS IN THE PRODUCT DAMAGES BASED UPON INCONVENIENCE LOSS OF USE OF THE PRODUCT LOSS OF TIME LOSS OF PROFITS LOSS OF BUSINESS OPPORTUNITY LOSS OF GOODWILL INTERFERENCE WITH BUSINESS R
11. ELATIONSHIPS OR OTHER COMMERCIAL LOSS EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES 2 ANY OTHER DAMAGES WHETHER INCIDENTAL INDIRECT CONSEQUENTIAL OR OTHERWISE 3 ANY CLAIM AGAINST THE CUSTOMER BY A THIRD PARTY End users are cautioned that system configuration software the application customer data and operator control of the system among other factors affect the product performance While NDSsi products are considered to be compatible with many systems specific functional implementation by the customers of the product may vary Therefore suitability of a product for a specific purpose or application must be determined by consumer and is not warranted by NDSsi This warranty gives you specific legal rights You may have other rights which may vary from locality to locality Some localities do not allow limitations on implied warranties and or do not allow the exclusion of incidental or consequential damages so the above limitations might not apply to you WARRANTY SERVICE REPAIR amp RETURN US AND CANADA ONLY Our standard warranty service is Repair and Return Repair and Return requires the defective unit to be returned to our service location for repair e Our service location will repair your unit within ten 10 business days The service time period does not include in transit shipping time to or from our service location Cost of shipment of the defective unit to NDSsi is the responsibility of the custo
12. ING RELIABILITY CAN ONLY BE ACHIEVED WHEN EQUIPMENT IS CONNECTED TO AN EQUIVALENT RECEPTABLE MARKED HOSPITAL ONLY OR HOSPITAL GRADE Technical Information 9 Unpacking and handling tips The Dome Sx display is a precision instrument that requires proper care to maintain product operation and adherence to specification Unpack the display and components carefully then set up and handle the unit properly to avoid damage to the LCD panel Use both hands to grasp the display case when lifting it from the shipping carton but avoid touching the screen Do not apply pressure to the screen or touch the screen with bare fingers or objects Pressure can affect image quality Cosmetics and oils on the skin are both detrimental to the screen and difficult to remove Allow the display to warm up to room temperature before turning it on Avoid sudden temperature changes in the environment as this may cause condensation which damages the display Secure the display properly onto a standard VESA 100 mm mounting unit if you elect not to use the desk stand Do not set up the display near strong light or heat sources Do not block the vents on the back of the display or install the display in a built in enclosure Blocked vents cause excessive heat to build up inside the display increasing risk of fire When installing components turn off your computer but leave it plugged into a grounded outlet Do not remove the back cover or di
13. PA DOME by NDSsi Domes Sx Display User s Guide 2012 NDS Surgical Imaging All rights reserved Information in this document has been carefully checked for accuracy however no guarantee is given to the correctness of the contents This document is subject to change without notice Go to web site ndssi com for the latest documentation NDSsi provides this information as reference only Reference to products from other vendors does not imply any recommendation or endorsement This document contains proprietary information protected by copyright No part of this manual may be reproduced by any mechanical electronic or other means in any form without prior written permission of NDSsi NDS Surgical Imaging NDSsi the NDSsi logo Dome the Dome by NDSsi logo Dome 3 Dome S3c Dome 10 Dome CXtra RightLight are either registered or unregistered trademarks of NDS Surgical Imaging All other trademarks are the property of their respective owners 020 0904 Rev02A About the Display The Dome Sx displays are available in 3 and 10 megapixels and contain a TFT LCD panel The display s thin film transistors in a transmissive type display use an integrated cold cathode fluorescent tube CCFT backlight system The display is designed for medical imaging in diagnostic settings and comes fully tuned with gamma correction that complies with the DICOM Part 14 Standard The all digital design enables the display to produce
14. S3c display only Install either the DVI or the DisplayPort video cable not both To connect the cables 1 Plug one end of the video cable into the video port on the connector plate Secure the connection 2 Plug the power cord into the power input port on the connector plate 3 Plug the other end of the cable into the video port on your computer system Secure the connection 4 Plug the other end of the power cord into the power supply 5 Plug the power supply cord s into a grounded AC outlet 6 Turn on the adapter power before you turn on the computer Installing the Display 5 6 Dome Sx Display Video Cable Installation on the Dome S10 Display Note the location of the primary input on the Dome S10 display shown below for proper video cable installation Improper connection may cause VGA boot messages not to appear on the display screen Primary video signal input on the Dome 10 connector plate Technical Information The design of the Dome Sx digital display takes into account every known measure to ensure your personal safety Improper use of the display can result in electric shock fire or damage to the display Read all instructions before setting up the display Classification Shock Protection Class I Degree of Protection Against Electric Shock No applied part Degree of Protection Against Harmful Ingress of Water Ordinary equipment IPX0 Degree of Safety in the Presence of Flammable Anaes
15. ce NDSsi configured a minimal operating system to exercise the display The resulting data are made available to interested parties This is informative data not certification data Certification data must be obtained by the device or system integrator according to Article 12 of the MDD titled Particular procedure for systems and procedure packs Paragraph 2 clearly outlines the device or system integrator s responsibility in this matter 22 Dome Sx Display In summary NDS Surgical Imaging is CE marking these displays under the Medical Device Directive which establishes compliance to the basic medical safety standards However EMC compliance can only be accomplished in the configured medical device or system and is the responsibility of the device or system manufacturer NDSsi has the necessary documentation such as IEC 60601 1 notified body and other third party test reports and certifications a risk hazard analysis an essential requirements checklist and the NDS Surgical Imaging International Electrotechnical Commission IEC declaration of conformity NDS Surgical Imaging located in San Jose Calif USA is the manufacturer of these displays in the meaning of the directive As required by the MDD in Article 14 NDS Surgical Imaging not residing in the European Economic Area EEA has a European representative NDS Surgical Imaging Nijverheidscentrum 28 2761 JP Zevenhuizen The Netherlands phone 31 180 63 43 56 fa
16. ctrical Equipment EN 55011 IEC 1000 3 2 IEC 1000 3 3 IEC 1000 4 2 IEC 1000 4 3 IEC 1000 4 4 IEC 1000 4 5 IEC 1000 4 11 IEC 1000 4 6 IEC 1000 4 8 CE EN 60601 1 Medical Electrical Equipment 24 Dome Sx Display Collateral standard electromagnetic compatibility requirements Limits and methods of measurements for radio interference characteristics of industrial scientific and medical equipment Harmonic emissions Voltage fluctuations flicker emissions Electrostatic discharge requirements for industrial process measurement and control equipment Radiated electromagnetic field requirements for industrial process measurement and control equipment Electrically fast transients for industrial process measurement and control equipment Surge requirements Voltage variations dips interrupts Conducted immunity Magnetic field immunity Conformance to the Medical Device Directive 93 42 EEC Part 1 General requirements for safety U S FCC Compliance Statement Class A Digital Device Dome 3 Dome S3c or Dome S10 Display This device complies with Part 15 of the FCC Rules NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio
17. d by NDSsi to be less than 250 cd m NDSsi will repair or replace the display at its sole discretion The displays must have been run in native color mode at or below the CXtra default brightness setting as configured from the factory If within 5 years of initial purchase the maximum output of the Dome E4c color display is determined by NDSsi to be less than175 cd m NDSsi will repair or replace the display at its sole discretion The displays must have been run in native color mode at or below the CXtra default brightness setting as configured from the factory Warranty amp Service Terms 27 EXCLUSIONS WHAT IS NOT COVERED 1 Any product with a defaced modified or removed serial number 2 Damage deterioration or a malfunction resulting from accident misuse neglect fire water lightning or other acts of nature unauthorized product modification or failure to follow instructions supplied with the product 3 Cosmetic damage including but not limited to scratches cracks dents markings glue and adhesive residue 4 Any damage of the product due to shipment 5 Any damage caused by factors external to the product such as electric power fluctuation or failure 6 Normal wear and tear including backlights dimming over time or image retention resulting from displaying fixed images for long periods of time 7 Removal installation and set up service charges 8 Failures not reported within the warranty term 9 Any N
18. d on the unit Wipe liquids off immediately to prevent damage to the display case and the screen WARNING DISCONNECT SUPPLY BEFORE SERVICING AVERTISSEMENT COUPER L ALIMENTATION AVANT L ENTRETIEN ET LE DEPANNAGE Shipping storing the display Keep the display in its shipping container until installation Return the display to its original container whenever you need to store the unit move it to another location or return it for repair The packaging supplied by the manufacturer protects the display while it is in transit See environment specifications for more information Before returning the display to the container do the following 1 Swivel the display panel to landscape mode 2 Push the panel down to the lowest position 3 Use the stand lock to anchor the panel Disposal information Follow your local governing ordinance and recycling policy for proper disposal or recycling of display components Technical Information 11 Dome S3 Specification In locations where 240V outlets are used connect the Dome S3 display to a center tapped 240V single phase supply only for Canada and the United States Category Screen Interface Input formats Physical Power Characteristic Item Type Screen size diagonal Resolution Pixel pitch Pixel arrangement Active area H x V Grayscale supported Refresh rate Contrast ratio Brightness Pixel rise fall time Viewing angle CR 10 1 Digital Video In Display
19. ePower BPM130S12F02 130W model Category Power input requirements Power consumption Power output requirements Physical Reliability Characteristic item Display Backlight Environment Characteristic item EMI shielding Temperature Humidity Characteristic Item Specification Voltage selection Voltage Current Frequency Wattage Voltage Current Size Weight Specification MTBF gt 50 000 hours Universal auto switching with medical approvals and PFC 100 240V AC 3 0A 50 60 Hz 90 W typical 12 V DC 5 10 8 A 130 W 228 6 mm x 76 2 mm x 50 8 mm 9in x3in x2in 1 3 kg 2 75 Ib MTBF 50 000 hours to 50 brightness with backlight on continuously operating storage operating storage Specification No emission of low level radiation 0 C 40 C 20 C 60 C 20 90 Relative Humidity noncondensing 5 90 Relative Humidity noncondensing Technical Information 13 Dome S3c Specification In locations where 240V outlets are used connect the Dome S3c display to a center tapped 240V single phase supply only for Canada and the United States Category Characteristic Item Screen Type Screen size diagonal Resolution Pixel pitch Pixel arrangement Active area H x V Color supported Refresh rate Contrast ratio Brightness Pixel rise fall time Viewing angle CR 10 1 Interface Digital Video In Display control brightness contrast Displa
20. ement Active area H x V Grayscale supported Refresh rate Contrast ratio Brightness Pixel rise fall time Viewing angle Digital Video In Display control brightness contrast Display identification USB hub on stand USB uplink on display Display status MQSA Landscape orientation Portrait orientation VGA XGA Screen type Display size without stand Display weight typical Mounting options Adapter 16 Dome Sx Display Specification 762 mm 30 0 in 4096 x 2560 pixels landscape 0 158 mm 161 dpi Single pixel IPS structure 645 1 x 403 2 mm 25 40 x 15 87 in 1024 shades of gray programmable gamma from palette of up to 4096 shades of gray 50 Hz 850 1 typical 700 1 minimum 1250 cd m typical 1000 cd m minimum when new 35 ms typical 20 ms Tr 15 ms Tf 170 85 horizontal vertical 2x DVI Rev 1 0 digital dual channel connector DDC2B EDID read using DDC2B N A Universal Serial Bus Rev 2 0 1 uplink mini B USB port Dual stack tricolor LEDs on back of unit Two color bottom facing LEDs on front of unit with push button activation 4096 x 2560 10 bit per pixel 2x 2048 x 2560 10 bit per pixel 640 x 480 to 1280 x 1024 AMLCD active matrix liquid crystal display 699 mm x 473 mm x 79 mm 27 5 in x 18 6 in x 3 1 in 7 7 kg 17 lb without stand 10 9 kg 24 Ib with stand Desktop stand standard 100 mm VESA mounting optional BridgePower BPM150S24F
21. mer Cost of shipment of the repaired unit to Customer is the responsibility of NDSsi duties and taxes to Canada are not included NDSsi reserves the right in its sole discretion to provide Customer with a comparable refurbished replacement unit in lieu of repair of customer s defective unit If NDSsi is unable within a reasonable time to repair or replace the defective unit it shall refund the purchase price for the product paid by the customer exclusive of taxes installation and shipping related fees Warranty amp Service Terms 29 CONTACTING NDSSI CUSTOMER CARE PRODUCT LINE Dome TOLL FREE 866 961 9340 LOCAL 503 620 3787 E MAIL medicalsupport ndssi com HOURS 6 A M 5 P M Pacific Time Monday Friday 1 Contact NDSsi Medical Support during the hours listed above Have your NDSsi model number and serial number available You may be required to provide proof of purchase as a condition for receiving warranty service 2 Our representative may perform troubleshooting and diagnosis of the problem by telephone or e mail If our representative is unable to fix the problem by telephone or e mail we will issue a Return Material Authorization RMA for the nonfunctioning unit and provide return instructions 3 Upon receipt of the returned product a service technician will evaluate the unit and confirm the failure description provided by the customer a If the found failure type is covered unde
22. ou have preset via calibration and monitoring software About the Display 3 4 Dome Sx Display Dome 3 Dome S3c connector plate Dome S10 connector plate The Dome Sx displays include the following components on the connector plate Power input On Dome S3 drives power to the display via an 8 pin DIN connector The power input is 12V 5 130 W On Dome S3c and Dome S10 drives power to the display via a 6 pin DIN connector The power input is 24V 5 150 W USB port Dome 3 Dome S3c uplink B port Usage to be defined at a future time Dome S10 uplink mini B port Usage assigned for MQSA button functionality e Video input Drives the data to the display The Dome 3 Dome S3c display offers two video connector options a standard DVI connector or a DisplayPort connector The Dome S10 display offers two standard DVI connectors e Reset button Restores the display configuration to default setting LED lights Provides information on the status of the display Installing the Display Turn your computer off Leave the power cord plugged into the grounded outlet Use the Dome Sx display with the power adapter and video cable shipped Warning In locations where 240V outlets are used connect the Dome Sx display only to a center tapped 240V single phase supply for Canada and the United States only Connecting the Video and Power Cables IMPORTANT For the Dome S3 or Dome
23. r warranty the repair parts labor and shipment back to the customer will be at no charge b If the found failure type is not covered under warranty NDSsi s then current evaluation fee will apply in addition to the cost of parts labor and the return shipment c If the unit is within the warranty period but the customer does not provide a problem description and the service technician cannot determine the failure no problem found NPF NDSsi s then current evaluation fee will apply in addition to return shipment 30 Dome Sx Display PAYMENT FOR NONWARRANTY EVALUATIONS AND REPAIRS AND OTHER EVALUATION CHARGES Nonwarranty repairs requested by customer will be performed at NDSsi s then current rates for any nonwarranty repairs and will include applicable evaluation fees and the cost of return shipping if customer requests that NDSsi ship the repaired product NDSsi further reserves the right in its sole discretion to request pre payment for any nonwarranty repairs NPF evaluations and return shipping charges prior to return of the product to customer Any invoiced amount not paid when due shall be subject to a service charge equal to the lesser of one and one half percent 1 5 per month or the maximum rate permitted by law If NDSsi undertakes collection or enforcement efforts customer shall be liable for all costs thereof including attorney s fees NDSsi reserves the right to suspend warranty coverage to any customer who
24. sassemble the display There are no user serviceable parts inside Preventing fire and injury 10 Dome Sx Display Replace the power supply or cables if damaged Use only the power source indicated in this guide or listed on the display Do not plug the power supply into an overloaded AC outlet or extension cord Overloaded AC outlets and cords can result in electric shock or fire Do not drop or push objects into the display case Internal components contain high voltage Unplug the power cord from the wall outlet during thunderstorms Do not place magnetic devices such as motors near the display Cleaning the display Observe the following guidelines to maintain the display and the LCD screen Use a clean lint free absorbent cotton cloth to clear off any residual glue from removal of the protective film or to remove surface dust Apply light pressure to remove the dust Dampen a clean cloth with a small amount of isopropyl alcohol to remove glue or dust if the screen is still not clean Do not saturate the cloth otherwise alcohol may seep into the display case and collect in the enclosure Use a clean dry cloth to completely remove the alcohol residue Do not use chemically treated dust cloths acetone toluene or harsh solvents on the display case or the screen They can damage the polarizer and the display case Do not expose the display to water or excessive moisture Do not allow water or other stains to stan
25. t Power Supply CAUTION Use only the power adapter supplied with the Dome S3c display unit the BridgePower BPM150S24F05 150W model Category Power input requirements Power consumption Power output requirements Physical Reliability Characteristic item Display Backlight Environment Characteristic item EMI shielding Temperature Humidity Characteristic Item Specification Voltage selection Voltage Current Frequency Wattage Voltage Current Size Weight Specification MTBF gt 50 000 hours Universal auto switching with medical approvals and PFC 100 240V AC 2 5A 50 60 Hz 108 W typical 24 V DC 5 6 25 A 150 W 223 5 mm x 63 5 mm x 38 1 mm 8 8 in x 2 5 in x 1 5 in 0 8 kg 1 8 Ib MTBF 50 000 hours to 50 brightness with backlight on continuously operating storage operating storage Specification No emission of low level radiation 0 C 35 C 10 C 35 C within specification 20 C 60 C 20 90 Relative Humidity noncondensing 5 90 Relative Humidity noncondensing Technical Information 15 Dome S10 Specification In locations where 240V outlets are used connect the Dome S10 display to a center tapped 240V single phase supply only for Canada and the United States Category Screen Interface Input formats Physical Power Characteristic Item Screen size diagonal Resolution Pixel pitch Pixel arrang
26. t version The Confirm File Replace dialog box appears if the installation CD contains a file older than the one currently on the system Click No to the question Over write the newer file Or click No to All When using commodity graphics boards on Windows XP systems make sure the check box for the function is empty unchecked When using commodity graphics boards with the Dome Sx displays be sure to install a DualLink DVI graphics board Regulatory Compliance Canada European Union United States This display has been tested and found to comply with IEC EN 60601 1 and IEC EN 60601 1 2 standards and is certified to meet medical standard CAN CSA 22 2 No 601 1 and UL 60601 1 The medical display in addition to meeting G WITH RESPECT TO ELECTRIC SHOCK F FIRE AND MECHANICAL HAZARDS ONLY medical requirements has been tested and found to comply with LR53545 the limits for Federal Communications Commission FCC Class A computing devices in a typically configured system since many medical offices are located in residential areas It is the system integrator s responsibility to test and ensure that the entire system complies with IN ACCORDANCE WITH UL 60601 1 CAN CSAC22 2 NO 601 1 Dome S3 Dome S3c and Dome S10 applicable electromagnetic compatibility EMC laws Warning to Users of Dome Sx Displays The Dome S3 Dome S3c and Dome S10 displays are Class A products In a domestic en
27. thetic Mixture with Air or with Oxygen or Nitrous Oxide Not suitable for use in the presence of a flammable anaesthetic mixture with air or with oxygen or nitrous oxide Mode of Operation Continuous No applied part Important recycle instruction bd HAZARDOUS SUBSTANCE Lamp s inside this product contain mercury This product may contain other electronic waste that can be hazardous if not disposed of properly Recycle or dispose in accordance with local state or federal laws For more information contact the Telecommunications Industry Association at WWW ECYCLINGCENTRAL COM For lamp specific disposal information check WWW LAMPRECYCLE ORG DISPOSAL Do not use household or municipal waste collection services for disposal of electrical and electronic equipment EU countries require the use of separate recycling collection services ENVIRONMENT FRIENDLY USE PERIOD Hazardous substances are present The number encircled by the recycling symbol indicates the safe use period in years China requires the use of recycling services at the end of product life Technical Information 7 A 8 Dome Sx Display Symbol explanations CAUTION Read the accompanying text carefully for proper operation and maintenance of the display system DANGEROUS VOLTAGE Important precautions about electric shock Read the accompanying text carefully to prevent damage to display components and to guard your safety DIRECT CURRENT B
28. tions STANDARD LIMITED WARRANTY COVERAGE NDS Surgical Imaging LLC hereinafter NDSsi warrants this product to be in compliance with the specifications provided by NDSsi and to be free from defects in material and workmanship as defined in such specifications Subject to the conditions set forth below NDSsi agrees to repair or replace any defective part of the enclosed unit for the length of period indicated on the chart below NDSSI PRODUCT STANDARD WARRANTY COVERAGE Dome E Series Radiology Displays Standard 5 year repair and return warranty Industry leading 10 year backlight warranty on grayscale displays Industry leading 5 year backlight warranty on color displays Dome S Series Radiology Displays Standard 5 year repair and return warranty Industry leading 10 year backlight warranty on grayscale displays Industry leading 5 year backlight warranty on color displays Dome GX Display Standard 3 year repair and return warranty If within 10 years of initial purchase the maximum output of the Dome Ex Sx grayscale display is determined by NDSsi to be less than 300 cd m NDSsi will repair or replace the display at its sole discretion The displays must have been run at or below the CXtra default brightness setting as configured from the factory t If within 5 years of initial purchase the maximum output of the Dome Ex Sx color display excluding the Dome E4c is determine
29. use in displaying and viewing radiographs of the breast for review and analysis by trained medical practitioners These displays do not provide a measurement function in any way and it is the device and systems manufacturer s responsibility to verify its function in the integrated device or system The display was classified as required by the MDD according to Annex IX of the directive and the medical device MEDDEV guidance available at the time of classification Because the display uses electrical energy and has no direct patient connections and by itself no medical utility the display is classified according to Rule 12 as an MDD Class device component or accessory The MDD states that manufacturers of Class medical devices or accessories shall satisfy the requirements in regard to design and manufacturing controls that is the applicable assessment route to be used for CE marking under the MDD and it shall carry the CE mark according to Annex XII of the directive with no Notified Body annotation The applicable safety standards for an MDD Class display are EN 60601 1 1990 along with A1 1993 A12 1993 A2 1995 and A13 1996 as well as IEC 60601 1 1988 along with A1 1991 and A2 1995 To help the medical device designer evaluate the suitability of these displays NDSsi has also conducted EMC testing to IEC 60601 1 2 as it can be applied The display with its power supply alone does not represent a functional medical device Hen
30. vironment either of these products may cause radio interference in which case the user may be required to take adequate measures Radio transmitting equipment cellular phones etc shall not be used in close proximity of the devices since this could influence the performance of the device Particular precaution must be considered during use of strong emission sources such as High Frequency surgical equipment and similar so that for example the HF cables are not routed on or near the devices If in doubt contact a qualified technician or your local representative Regulatory Compliance 21 We offer state of the art displays suitable to the European market CE marked displays based on compliance with counsel directive 93 42 EEC commonly referred to as the Medical Device Directive MDD The following summarizes our qualification of these displays as it relates to compliance with the MDD The European Medical Device Directive requires that the intended use of the device be defined The intended use of these displays is to display alphanumeric graphic and image data as inputted from any type of medical device Specifically the Dome S3 and Dome S3c displays are intended for use in displaying and viewing medical images for review and analysis by trained medical practitioners The Dome S10 display is intended for use in displaying and viewing medical images for review and analysis by trained medical practitioners or intended for
31. x 31 180 63 21 91 In the opinion of NDS Surgical Imaging registration required to put this device into commerce is the responsibility of the medical device system manufacturer and NDS Surgical Imaging supports this requirement by providing a European Commission EC declaration of conformity If NDS Surgical Imaging supplies a display to an end user rather than a device manufacturer it is the end user s responsibility to ensure continued compliance with the MDD of the system in which the display is integrated The supplier will make available on request circuit diagrams component part lists etc For vigilance reporting as required under Article 10 of the MDD NDS Surgical Imaging will provide any information requested by competent authority to support any reported incident investigation by such an authority Regulatory Compliance 23 EU Declaration of Conformity for Medical Application A Declaration of Conformity has been filed for this product For additional copies of the Declaration of Conformity document contact NDS Surgical Imaging The Dome Sx digital flat panel display meets the essential health and safety requirements is in conformity with and the CE marking has been applied according to the relevant EU Directives listed below using the relevant section of the following EU standards and other normative documents EU EMC Directive 2004 108 EC EU Electromagnetic Compatibility Directive EN 60601 1 2 Medical Ele
32. y identification USB hub on stand USB uplink on display Display status Input formats Landscape orientation Portrait orientation VGA XGA Physical Display size without stand Display weight without stand Display weight with stand Mounting options Power Adapter 14 Dome Sx Display Specification AMLCD active matrix liquid crystal display 540 mm 21 3 in 1536 x 2048 pixels portrait 2048 x 1536 pixels landscape 0 2115 mm 120 dpi R G B vertical stripe 433 2 x 324 9 mm 17 05 x 12 79 in 16 7 million colors 256 shades of gray programmable gamma from palette of up to 2041 shades 60 Hz 750 1 typical 600 1 minimum 700 cd m typical 550 cd m minimum when new 24 ms typical 14 ms Tr 10 ms Tf 170 85 horizontal vertical DVI Rev 1 0 digital dual channel connector DisplayPort Revision 1 1a connector DDC2B EDID read using DDC2B N A Universal Serial Bus Rev 2 0 1 uplink B port Dual stack tricolor LEDs on back of unit 2048 x 1536 24 bit per pixel 30 bit per pixel via DisplayPort 1536 x 2048 24 bit per pixel 30 bit per pixel via DisplayPort 640 x 480 to 1280 x 768 pixels displayed in portrait orientation 472 mm x 363 mm x 102 mm 18 6 in x 14 3 in x 3 9 in 6 4 kg 14 0 Ib typical 9 3 kg 20 5 Ib typical Desktop stand standard 100 mm VESA compliant mounting BridgePower BPM150S24F05 with power switch CAUTION Use only the adapter supplied with uni
Download Pdf Manuals
Related Search
Related Contents
S67H 連続式揚物機3号 Switch controller for obtaining a plurality of functions from a single MODEL400 シリーズ - ミナトホールディングス株式会社 Method and apparatus for automatic generation of object oriented #73-046 Rev. C_Nitrokit_Manual.indd EGW200 - User Manual (EN) Sitecom Wireless Concurrent Dualband Router 300N 調色用機器・機材類 fisher-price.com CHN44 Copyright © All rights reserved.
Failed to retrieve file