Home
DST adjustments for Natus Screening Products
Contents
1. Control Panel settings on the Windows menu You will need to check your computer s time on April 8 2007 and October 28 2007 previous daylight savings days to check for automatic changes by the Windows operating system As these dates are no longer valid if your computer has adjusted the system time you will then need to undo any automatic time changes by moving your clock back one hour on April 8 and forward one hour on October 28 At 2 00 AM on November 4 2007 you will need to manually set the computer s system time backward one hour using the Control Panel settings on the Windows menu You should also consult with your institution s IT or Biomed department s to inquire about any institutional software patches that may be applied for this change in Daylight Savings Time alGO Newborn Hearing Screener Model 2e Color from the ALGO 2e Color User Manual Setting the Date and Time Section 4 5 The Algo2eC switches the time automatically and this will happen on April 8 2007 at 2 00 am Clients with this equipment will need to set their clocks on two separate occasions March 11 2007 and again on April 8 2007 At 2 00 AM on March 11 2007 you will need to perform the following steps to adjust your system for daylight savings time From the Main Window Press F11 or click on User Preferences Enter the password Position the cursor in the time field and type the current time in the 24 hour clock format e g 11 00 PM 23 00 Clic
2. k the save button at the bottom of the page This button will become inactive after the save is complete Select Main Window to return to the Main Window Screen a ON At 2 00 AM on April 8 2007 the Algo2eC will automatically adjust for daylight savings time under the old rules This will adjust your clock forward one hour and it will be necessary to set the clock back The above instructions can be used to reset the clock At 2 00 AM on October 28 2007 the Algo2eC will automatically adjust the clock to Standard Time and it will be necessary to again adjust the clock forward one hour At 2 00 AM on November 4 2007 it will be necessary to again adjust the clock back one hour to Standard Time The above steps will suffice for all adjustments from the ALGO 3i User Manual Section VIII under Device Set up Manually adjust time and date on March 11 2007 per the following instructions From the main Window Using the up and down arrow buttons highlight Device Setup and press the green OK button Using the up and down arrow buttons highlight User Preferences and press OK Using the up down left right toggle key enter the password and press OK Using the up and down arrow keys highlight Set Current Time and Date and press OK Using the up down left right toggle key adjust the time and then press OK Press the X button to return to the Device Setup Screen Press the X button to return to the Main Screen SLOP od T ae hea No addi
3. natus MEMORANDUM SUBJECT Changes in Daylight Savings Time TO all ALGO 3 ABaer ALGO 2e Color ALGO 3i and ALGO Portable device customers FROM Natus Technical Service Dear Valued Natus Customer Beginning in 2007 most of the United States begins Daylight Saving Time at 2 00 a m on the second Sunday in March and reverts to standard time on the first Sunday in November In the U S each time zone switches at a different time Please reference the instruction set appropriate for your device s to ensure proper setting for each device s time ALGO Newborn Hearing serneest from the ALGO 3 User Manual Setting the Date and Time Section 4 5 Manually adjust time and date on March 11 2007 per the following instructions which can also be found in the User Manual From the Main Window Press F11 or click on User Preferences Enter the password Position the cursor in the time field and type the current time in the 24 hour clock format 11 00 PM 23 00 Click the save button at the bottom of the page This button will become inactive after the save is complete Select Main Window to return to the Main Window Screen ee No additional adjustment will be needed until November 4 2007 when you can use these instructions again to set the clock back to Standard Time Tip acer hearing screening system At 2 00 AM on March 11 2007 you will need to manually set the computer s system time forward one hour using the
4. tional adjustment will be needed until November 4 2007 when you can use these instructions again to set the clock back to Standard Time echo screen from the Echo Screen User Manual Section 11 under Date Time Manually adjust time and date on March 11 2007 per the following instructions From the Main Window Use the up and down arrow buttons to highlight options and then press OK Use the up and down arrow buttons to highlight Settings 1 and press OK Use the up and down arrow buttons to highlight Date Time and press OK Use the right hand arrow key to select the cursor position on the screen and highlight the appropriate time setting Change as needed with up and down arrow buttons and then press OK to save the settings 5 Press the left hand arrow key to return to the Main Window w No additional adjustment will be needed until November 4 2007 when you can use these instructions again to set the clock back to Standard Time ALGO portable Newborn Hearing Screener No internal time or date is kept on the device therefore no action required If you would like assistance adjusting the time on your Natus newborn hearing screener or have any questions please call Technical Service at 1 888 496 2887 or 1 650 802 0400 ext 686 for the ALGO or Echo Screen hearing screeners or at 800 272 8075 for the ABaer hearing screeners
Download Pdf Manuals
Related Search
Related Contents
0 - Ideals Samsung CS-21Z45M5 User Manual Tutoriel Android Lavorare in sicurezza con la motosega WWW.BEGLEC.COM Operation Manual Mode d'emploi HP Omni 200-5340pt - Nutter Rod & Reel Service Comparison of application virtual machines MANUAL DE USUARIO Copyright © All rights reserved.
Failed to retrieve file