1. SHIFT PROG FNC The white keys of the TPS1100 keyboard are fixed keys 14 Most of them are accessible anytime during operation Standard coding key Accessible from the measurement dialog and from the TPS1100 application programs Illumination and display settings e Display illumination contrast and heating e Reticule illumination Activate the Red Laser beam option for TCR inst e Activate the guidelight EGL option Accessible anytime Electronic level and laser plummet Accessible anytime Program key for TPS1100 standard or Geobasic programs Accessible anytime Fixed functions key contains functions that shall be quickly accessible during measurement or from any location like ppm settings or reflector selection Accessible anytime Battery Display all Ea The battery status is displayed beside the title bar Battery fully charged Battery almost fully charged Battery still capable to be used Battery reserve power about 25 more distance measurements possible There are two different battery symbols Internal battery is used External battery is used 15 16 Graphical status icon The column to the right of the display is reserved for graphical status icons Recording device and communication iw PC Card is inserted Data is recorded o PC Card inserted Data can not be r
2. SHIFT SHIFT SHIFT SETH N gt DIS Re m r wo I lt gt II INDIV FNC Fixed function key List of the functions available in the dialog Measure amp Record To set a new value for the horizontal angle circle reading To modify the display content according to the predefined display masks Standard 1 Angles and distances e Standard 2 Offset and Coordinates e Standard 3 Point Code and Attributes To manually enter a distance To delete the last block registered in the measurement job The last block can be a measurement or a code block Motorized instruments changing between face and face Il Manual instruments displaying the Hz and V differences up to the other face The instrument must be moved manually by the user until the differences are 0 To enter an individual point Id After the entry of the individual point Id the running point Id is displayed again The fixed key Hee provides direct access to additional functions which might be needed during measurement see next chapter 35 TAO Introduction The fixed key NC provides direct access to a number of functions that are particularly useful during measurement Call the ENS function from any dialog FNC C B 1 PPM Atmospheric 2 Reflector selection E 3 EDM Program selection 4 Check Orientation 5 Data view an
3. aud ONES ae y 12 1300 i H LE L E Aim to the backsight point oy Enter the azimuth value e g 30 0000g To set the orientation and return to the station data dialog MAIN Enter Station Data y Station Id ST1 Inst Ht 1 600 mi Stn East 4132 143 m Stn North 3093 967 m Stn Elev 450 070 m Hz 3 30 000 g L CONT REC SetHz IMPOR ma To record the station data in the measurement job optional To set the station and continue to the measurement dialog 31 O Quick Set with orientation to one hacksight point This function is used for station setup and instrument orientation 32 given the station coordinates and the coordinates of one backsight point You can enter the station backsight coordinates manually or import them from the data job Call the Quick Set function from the Job settings dialog Main Job settings y el Main Quick station setup ZAE Station Id ST1 Backs Id Bs200 U Inst Ht 1 650 m Refl Ht 1 700 m AHorizDist 2 m Measure to Backs point ES ee T Sy Enter the Station Id If available the coordinates are automatically retrieved from the data job Sy Enter the Backsight Id SHIFT REGI Press ray to view the coordinates of the highlighted value Station or Backsight Id DIST SHIFT ita o E REC o E Press EET manually enter
4. Point codes can be entered manually or selected from a codelist containing predefined point codes Such a codelist can be created with the PC software Codelist Manager Please refer to the on line help of the Leica SurveyOffice Software for more information 95 Manual point code entry gt DISP ALL Point code entry in the measurement dialog 96 To toggle the display mask until Point Code and Attributes are displayed as shown below CH B Point Id 112 Point Code rer Attrib 1 2 Attrib 2 Attrib 3 Attrib 4 DIST REC SS gt DISP Enter the point code and up to 8 attribute values To simultaneously measure a distance record the measurement data the point code and the attribute values To record the measurement data the point code and attribute values The entered point code and its attributes will be recorded everytime or are pressed The point code and attributes are recorded together with the measurement data in the GSI measurement block as WI71 WI79 if defined so in the REC Mask In order to enable the point code selection from a codelist you must have selected a codelist in a previous step Meas Measurement amp Record EW Point Id 112 k Point Coding with a codelist Point Code Pre Y Position the cursor bar on the point code field lt Enter the point code to be searched for e g 12 The correponding
5. System Field Manual English Version 2 2 The quick way to start with the TPS1100 To use the equipment in the permitted manner please refer to the n detailed safety instructions in the User Manual 2001 Leica Geosystems AG Heerbrugg All rights reserved Getting started 6 Operating concept 12 Recording Concept 24 Illumination EGL 26 Setup Measure and Record 28 FNC Fixed function key 36 EDM Functions 47 ATR Functions 53 PowerSearch 62 RCS Functions 64 Main Menu Functions 72 Standard Coding 87 Point Coding 95 Instrument map 102 How to use this Manual This field manual gives step by step introductions for the use of the 4 TPS1100 system software It has two objectives To introduce a novice user to the basic operation concepts and the practical use of a TPS1100 totalstation We recommend that new users have the instrument set up while they read through this manual 2 To serve as handy field reference for the experienced user during his daily work To have the manual at your hands when you need it we recommend to store it in the appropriate slot in the instrument transportation case Symbols used in the sequence of operation PROG Press fixed key PROG User input is necessary Press function key F1 to activate the function ALL SX ALL O Repeat operation Other Symbols m Important information and tips nee Optional function not part of the standard sequence o
6. 5 Codes with Info s To return to Codelist Selection dialog 83 Data conversion Call the Data conversion function from the Main menu 84 MAIN Main Menu A SN l MAIN File selection C Source path A Y sy Set the file selection parameters Source path Selection of the source file path on the PC Card Source file Selection of the file to be converted from the choicelist Format Display of the source file format Output path Selection of the path for the output file t Select the path a GSI for GSLfiles to be further used on the instrument Output file Filename of the output file The filename and its default extension can be modified Note that the extension must be part of the filename Format Selection of the output format GSF8 GS 16 or ASCII To start the file conversion the function is available only if the file selection matches with the program configuration Call the Data conversion configuration from the Data conversion File selection dialog MAIN File selection AB TAN Configuration AH ig Source file settings Data conversion configuration CONF y Set the source file parameters first Search extens Entry of the source file extension If the source format is GSI the extension must be GSI If the source format is ASCII the extension is user definable e g TXT ASC etc Only the files with defined extension will be disp
7. FNC Check Orientation i Station Id STN Bscks Id BS Refl Ht 1 600 m Azimuth 8 95 6670 g Hz 95 6650 g AHz 0 0020 g CONT DIST POSIT SET VIEW LAST O H Reset the orientation lt lt Enter the Backsight Id If available the coordinates are automatically retrieved from the data job Aim to backsight point and compare the angles Azimut Calculated Azimut between station and backsight Hz Current orientation AHz Difference between calculated azimut and current orientation To return to the dialog from which FNC has been started Data View and Edit 2 Data View and Edit allows to search for a point or a code in the measurement job and or to manually enter new points Call the dialog for data view and edit from the Function selection dialog FNC File amp Pt Selection W FNC Function selection y el Rec device PC Card Mem Size 3936 0 KB Free z 2999 0 KB PtId Code 123 File MYJOB GSI A VY File size 54 7 KB I Enter new point coordinates Enter the point Id or the Code to be searched for in the measurement job To start the search and display the data found To return to the dialog from which FNC has been started For more details refer to the chapter Main Menu Functions 41 Job settings Job settings allows to modify the current jobs and codelist and the 42 display and recording mask Call the Job settings dialog from the Function selection
8. Input new point coordinates SHIFT EDIT INPUT N REC Call the Edit function from the job selection dialog then the Input function MAIN Selection lt gt iy Bll l Data File amp Pt Selection fm Al Data Enter coordinate set EW Data job SURVEY1 GSI A V Enter min PointId E N Indiv PtId 123 East Be m North Eoo o taaan m Elev Eoo ee m a ee ee el Enter point coordinates Indiv Ptld Point Id of the new point East Easting coordinate North Northing coordinate Elev Point Elevation optional To record the point coordinates in the selected job To return to the File amp Pt Selection dialog To return to the Main Menu 79 Codelist management CONT EDIT COPY Call the Codelist Management from the Main Menu 80 Note if no codelist has been found you will be prompted to define a new codelist MAIN Main Menu Main Codelist Selection lt mei Code Surveying CONT NEW EDIT COPY DEL oNUM No codelist is selected when the cursor bar is positioned on the dots To select the highlighted codelist To create a new codelist To display the list of codes for the selected codelist Access to the entry of new codes To copy the selected codelist from the internal memory of the instrument to the PC Card and vice versa To delete the selected codelist Croate na
9. point code will be highlighted Meas Measurement amp Point Code House Corner Pit Electricity Pole CONT NEW LAST JATRIB A Code search settings Em alpha numerical search numerical code search LU To confirm selection and to return to the measurement dialog 97 ALL Meas Measurement amp Record iw 98 Point Id 112 Point Code MEMME To simultaneously measure a distance record the measurement data and the selected point code To record the measurement data and the selected point code The selected point code will be recorded everytime or are pressed The point code will be recorded together with the measurement data only if defined so in the REC Mask Check your REC Mask to make sure that the point code belongs to your REC Mask Advanced Feature Enter attributes Meas Measurement amp Record EF 2 Point Code 1 a House Corner Symbol for 14 Pit a Point Codes Electricity Pole with Attributes CONT NER L CAST E Oe To recall the last entered Point Code and Attributes To enter additional attribute values to the point code and or check default values possibly defined in the codelist 99 EECA Stee ne A 100 Point Code 12 PtC Descr Tree Atab A a L O NEWA CLEAR D To enter new attributes y Enter the value for the corresponding attribute E Note that user input is not possible if the attribute can not be
10. recorded in the measurement job In this case check and modify the REC mask definition To accept the point code and the Attribute values and return to the measurement dialog Advanced Feature Enter new point code cea To enter a new point code to the currently selected codelist Meas Enter New Point Code EF B Code 2 12 PtC Descr Tree Attrib 1 sy Enter the point code data Point Code Point Code to be recorded in the measurement job PtC Descr Description of the Point Code optional This information will not be recorded Attrib 1 Attribute to be recorded together with the Point Code in the measurement job km To accept the point code data and return to the measurement dialog The new point code is added to the codelist 101 102 Instrument map LS Cs a Measurement functions CODE PROGI FNC SHIFT ESC Q Standard Coding Manual entry or codelist selection if codelist selected Measure and record functions ALL DIST REC Quick Coding On Off QCOD Light settings Set Hz reading SetHz Display light DISP Toggle display mask gt DISP Display heating HEAT Manual distance input D INP Reticule light RETI Face Face Il I lt gt ll EGL option EGL Delete last rec block DELB Red Laser option REDL For individual Pt Id INDIV Level and Laser Plummet Stat
11. all measurements Offs Cross Elev Offset point is higher than measurement 1100QS07 l To accept increment and or offset values and return to the dialog from which FNC has been started EDM Testsignal freq Call the function for testing the EDM signal strength and frequency from the Function selection dialog el NC Function selection LAB Signal Strength O es 100 98 Tone 8 ON Y FNc EDM Return Signal iw To display the EDM frequency The strength of the signal returned by the reflector is displayed in procent on the instrument CONT To return to the dialog from which FNC has been started 45 Compensator Call the Compensator dialog from the function selection dialog 46 FNC Function selection ll iw E Compensator ON OFF Hz Corrections ON OFF Compensat On Vv Hz Corr 5 On Y LE A a A a ly Select the compensator and Hz corrections settings Compensat V angles are corrected and relate to the plumb ON line Compensat V angles are not corrected and relate to the OFF standing axes Hz corr ON Hz angles are corrected for Hz V collimation Standing axis tilt is corrected only if Compensat ON Hz corr OFF Hz angles are not corrected MU To return to the dialog from which FNC has been started EDM Measuring Program dialog EDM Functions The selection of the EDM Measuring program
12. com
13. found In this case you need to manually aim at the prism the instrument will lock to the prism without additional distance measurement LOCK interrupt FNC L INT To temporarily interrupt lock mode call the FNC key from any dialog FNC Function selection y 1 PPM Definition 2 Reflector Selection l E EE To interrupt lock and return to the previous dialog There are 3 possibilities to re lock the instrument to the prism Approximatily aim at the prism and measure a distance e Approximatily aim at the prism and reactivate lock with the function c from the Function selection dialog e Press in the Program selection dialog to position the instrument to the last recorded point Note that you can t measure distances to side shot points by interrupting the lock mode To do so you need to switch the lock mode off 61 Introduction Search modes 62 PowerSearch PowerSearch is an option for the TPS1100plus series that enables the instrument to find a prism at any desired position within a short period of time When PowerSearch is activated the instrument starts to rotate around its standing axis The transmitter emits a vertical laser swath If the laser swath detects a prism the rotation of the instrument is stopped Afterwards a fine aiming in vertical direction is performed by the ATR If no working area has been defined then the instrument rotates 360 around its standing axis
14. mode with the ENTER key nee To record the selected code and to return to the previous dialog 89 Advanced Feature C E 90 Code Enter Info E 13 House Corner po lt a Symbol for 14 Pit x Cod ith 15 Electricity Pole CESI Code Infos To recall the last entered code and Info s To enter additional code Infos and or check default Info values possibly defined in the codelist Meas Enter Info value Eie Code g 12 Code Descr Tree Diameter rrr M E E a LEAR f To enter new Info values ly Enter the value for the corresponding code Info Ea To record the code and the Info values Advanced Feature Enter new code EEJ To enter a new code to the currently selected codelist zae Code 12 Code Descr Tree Info 1 5 ee sy Enter the code data Code to be recorded in the measurement job Code Descr Description of the code optional This information will not be recorded Info 1 Info to be recorded together with the code in the measurement job To record the code data in the measurement job and add the new code in the codelist 91 Advanced Feature Quick Coding Quick Coding is a special function for data collection with coding 92 With one keystroke you can measure and record target points with code data The codes must be available in a codelist which has been defined with the Codelist Manager from your Leica SurveyOffice Software The codes mu
15. position the cursor on the digit to be edited The digit can be overwritten now You can change between numeric and alphanumeric input with the key Be To confirm the entry Input fields marked with a triangle have a predefined list of values e g Refl list in dialog below FNC Reflector Selection W Refl list TEREN Input from a choicelist Standard selection method To open the choicelist FNC Reflector Selection y Refl list Leica circ prism I Leica mini prism Leica 360 prism To set the cursor bar on the corresponding value To start the aphanumeric search for the desired value E The search feature is available only for longer lists To select the highlighted value and close the choicelist Quick selection method To toggle through the choicelist and select the corresponding value 23 Recording Concept im PC Cards are used as external memory device on TPS1100 PC Card instruments m Both SRAM and ATA Flash PC Cards are supported Files and directories The PC card can contain any kind of files whereas the following files are used or created on the TPS1100 instruments Type of file Extension Fixed Directory Meas Job file for recording measurement data GSI PC Card GSI Data job file containing control data GSI PC Card GSI Codelist codelist file REF PC Card CODE ASCII files files with control data in ASCII format A
16. SC free The filenames are all user defined The file extension and the file location on the PC Card are fixed depending on the type of file Data Format The measurement data can be recorded in GSI 8 or GSI 16 format on the PC Card The control data must be available in GSI 8 or GSI 16 format on the PC Card Control data in ASCII format can be converted to GSI format on the instrument using the data converter Formatting a PC Card The PC Card can be formatted on the instrument MAIN Configuration LH lo AIN PC Card LM fo if MAIN Format PC Card AB Bl Warning 1151 _ Formatting deletes all data on the PC Card PK ABORT lt a To format PC Card E When the PC Card is formatted all data are irretrievably deleted 25 enw Lights heating ON OFF ISP ETI EGL RedL iE Be Ge GEE 5 a Illumination EGL Wi The illumination dialog can be called anytime ILLUMINATION iw v Display Heating X Contrast 50 V X Reticule 50 V X EGL 50 V X E Red Laser X MN a NA Use the function keys to switch the lights or the heating ON OFF To turn the display heating on To turn the display illumination on To turn the reticule illumination on To turn the EGL electronic guide light on only for TPS1100 instruments with EGL option To turn the red laser beam on only f
17. and PowerSearch scans the entire horizon e Ifa working area is defined and activated then PowerSearch only scans within the defined limits Starting a search PROG PowerSearch can always be called up in the menu PROG Calls up the menu selection 1 Free Station PROG Program selection i CUA LAST Rcs If RCS mode is activated then after triggering ATR search with ALL resp DIST the following dialogue is displayed Measure and Record LA Notice 1460 Searching for Target Press F1 PS to switch to PowerSearch PPS ABORT By pressing PS F1 the ATR search can be switched to PowerSearch for a quick prism search 63 RCS Functions hi RCS stands for Remote Control Surveying RCS enables all TPS1100 instruments to be remote controlled Especially qualified for this purpose are the instrument types with ATR The keyboard of the RCS1100 Controller is the same as the TPS1100 keyboard All functions and programs of TPS1100 instruments are available on the RCS1100 Introduction The communication between the instrument and the RCS1100 is established via radio modems One radio modem TCPS26 must be connected to the TCA s serial port As the RCS1100 has an integrated radio no additional connections are needed RCS mode must be switched on at the instrument first After all connections have been made the RCS1100 can be switched on TCPS26 This automatically switches on
18. ation of controller display Power off mode of the controller Key beep mode Heating of the controller display To confirm the settings and exit the dialog Functions configuration FNC VY gt 2 sec Press down the FNC key for more then two seconds until the dialog RCS Configuration is displayed RCS Configuration y 1 Select language r This dialog gives access to following functions To select the language to be displayed on the RCS controller To select the TPS1100 mode To set the serial interface parameters of the RCS controller They must correspond to the TPCS26 default settings 19200 baud 8 data bits No parity To configure the link number which must be changed at the same time on both radio modems Therefore the TCPS26 must be connected to the RCS Controller 71 F 7 72 EL a ES The Main Menu is the first dialog displayed when the instrument is switched ON a A 1 Meas job management 2 Data job management 3 Codelist management 4 Data Conversion 5 Configuration 6 Instr calibration Access to the SEP JX dialog gt Measure amp Access to the setup procedure Record E If desired you can configure your instrument to start up with a dialog of your choice function Power On Power Off autoexec see chapter Instrument map General description of the Meas and Data job management allows to main menu functions Select the measurement and da
19. cked LOCK to prism has been lost Search in progress Functions available in the second level of functions keys SFT has been pressed Further digits need to be keyed in Displayed when a menu has more than 10 entries Quick Code is active The numeric keys are reserved for Quick Coding You can select a function from a menu using the standard or the quick method The example below shows how to select the function Configuration from the main menu dialog ES ee 2 2 Data job Management 3 Codelist Management 4 Data Conversion 5 Configuration 6 Instrument Calibration ee n aaa aaan SETUP MEAS Select a function from a menu To scroll the cursor bar until the function Configuration is highlighted To confirm the selection and start the function Standard method Quick method sy Press the corresponding numeric key Pal to select and start the function Configuration E For long menus with 10 items or more both digits displayed in front of the function must be entered 19 User Input Numeric input Enter a new value E User input field are shown in inverse mode on the display 20 TPS1100 has three types of input fields e Numeric input fields only numeric values are allowed e g for the reflector height Alphanumeric input fields both numeric and alphanumeric values are allowed e g for point Id e Input from a choicelist only valu
20. create new job and continue to the job selection dialog MAIN Selection lt gt Meas Job DEFAULT GSI SURVEY1 GST PC Card Search and view data Call the Edit function from the job selection dialog MAIN Selection lt gt fw ire Data File amp Pt Selection m Rec device PC Card Mem Size 3936 0 KB Free q 2999 0 KB PtId Code Src File MYJOB GSI A V File Size 54 7 KB ETNO E T a A EDIT Ly Enter the point Id or the code to be searched for m The decimal point can be used as Wild Card 12 search the points beginning with 12 A search the points containing A 5 search the points ending with 5 lt Select the search file SEAR To search for point or code data in the selected file 77 View edit data SHIFT E3 E SHIFT SHIFT Data Data View and Edit 45 78 E Point Id 123 East 3 1154 453 m North 3444 699 m Elev 453 444 m CONT NEW S lt gt gt lt lt REP REP gt gt Values accessible with the cursor bar can be edited e g point Id Code Info s To display the previous or the next data block in the file To search for the previous or the next data block for specified point Id or code To return to the job Selection dialog To start a new point Id or code search To display the first or the last point of the file To delete the displayed data block
21. d edit 6 Job settings A 7 Increment amp Offset 8 EDM Test signal freq 9 Compensator Start a function by highlighting it with the cursor bar and pressing the od key or simply by pressing the corresponding numeric key PPM Atmospheric lt PPM total manual entry The PPM atmospheric dialog calculates the atmospheric ppm given the atmospheric pressure and temperature If needed the ppm total value can be entered manually Call the dialog for PPM atmospheric settings from the Function selection dialog FNC Function selection W FNC PPM Corrections i Enter your corrections values Atm pressure 1020 0 mbar Temperature 25 0 C ppm total 4 10 9 O E E E Enter the atmospheric pressure and the temperature The ppm total value is computed according to the Barrel and Sears equation see TPS1100 User Manual To accept the values and return to the dialog from which FNC has been started Position the cursor bar on the ppm total value with the cursor key and enter a new value The values for Atm pressure and Temperature are deleted 37 Reflector Selection N CONT The Reflector selection dialog allows to select predefined reflectors 38 from a list The definition of new reflectors with corresponding addition constant is possible Call the dialog for Reflector selection settings from the Function selection dialog FNC Function selection y el FNC Reflect
22. dialog FNC Function selection D E FNC Job settings Meas Job DEFAULT GSI Y Data Job DEFAULT GSI V Codelist 2 y Disp1l Mask Standard 1 V REC Mask Polar 8 Y i E E fF a To define a new job N Select corresponding measurement job data job codelist display mask and recording mask To accept values and return to the dialog from which FNC has been started Increment amp Offset This dialog allows to define the increment of the point Id The Cross length and or elevation offsets can be defined for any target point too Call the Increment amp Offset dialog from the Function selection dialog Cam oj p C B Point Id 200 Increment 10 Offs Cross 0 000 m Offs Lngth 0 000 m Offs Elev 0 000 m Offs Mode Reset after REC Y CONT a sSOFS O Reset offset values to zero Increment aN Enter the point Id increment and the starting point ID in order to increase the running point no after every record For instance Increment 10 starting point Id 200 point Id s are 210 220 230 240 etc 43 Enter Offset values 44 Offset PT aN Enter offset values for the displayed point Id according to the sign convention explained in the illustration Sy Define corresponding Offset mode xs G gt gt Reset after REC The entered offset values are reset to zero after S the point has been recorded Permanent The entered offset values are applied to
23. e FNC fixed key from any dialog to switch the ATR on C B 1 PPM Definition 2 Reflector Selection 3 EDM program selection 4 Check Orientation 5 Data view and edit Gi ON gt G 6 Job settings OFF gt no icon S a N E E To switch ATR on and return to the previous dialog The ATR icon C is displayed in the status icon column of the display To switch ATR off ATR is a general function If switched on it is active at station setup during data collection and within all TPS1100 application programs To start the Automatic Target Recognition process you need to trigger a distance measurement with ALL or DIST Example Measure amp Record dialog Meas Measure amp Record D Point Id 123 Refl Ht 1 700 m Hz 222 3444 g Vv E 82 3467 g Horiz Dist m Elev Diff 9 m DIST REC SetHz gt DISP To automatically position the telescope to the prism centre measure angles and distance and record measurement data To automatically position the telescope to the prism centre measure and display the distance to the prism SetH ATR is also active in the function for setting the orientation to a reflector with following procedure e Approximatively aim at the reflector Enter the azimuth value ATR will position the telescope to the reflector centre Set the orientation If you want to use to set the orientat
24. ecorded i t No PC Card inserted Dat tb ded RS 232 is selected as recording device GSl communication is SS possible EEE Remote Control RCS is active RS 232 is selected for RCS communication RS 232 is selected for GeoCOM communication Compensator a EAA 5 Beko Compensator functions normally and Hz directions are corrected Instrument is tilted or unstable or has been turned too quickly Compensator and or Hz corrections are disabled Infrared distance measurement active This icon shows up only on instruments with the option reflectorless EDM Infrared distance measurement active and laserpointer switched on This icon shows up only on instruments with the option reflectorless EDM Reflectorless distance measurement active visible red laser Reflectorless distance measurement active visible red laser and laserpointer switched on Longe range distance measurement active visible red laser Longe range distance measurement active visible red laser and laserpointer switched on 17 Automatic Target Recognition lo Key Mode Field fo fal IPI 18 ATR and LOCK inactive Automatic target recognition ATR active Automatic target tracking LOCK active But no prism has been aimed at or lock to prism has been lost LOCK is active prism is tra
25. es included in a predefined list are allowed Position the cursor bar on the corresponding input field e g Refl Ht Es Measure amp Record AS Point Id 121 Refl Ht Use the keys E to H to enter a new numeric value The initial value is deleted after the first keystroke You can recover it with ES To confirm the entry Edit highlighted value Alpha numerical Input N To start the edit mode for the highlighted value Meas Measurement amp Record EW Point Id 121 r Ref1 Ht 1 6509 m Insert mode i SSC ON OFF The cursor is positioned at the end of the value to be edited To position the cursor on the digit to be edited The digit can be overwritten now To confirm the entry In alphanumeric mode one key is used for the input of 3 letters and one number For instance the key Fal is used to input the letters S T U or the number 1 Press H once to input the letter S Press EJ twice in quick succession to input letter T three times to enter letter U and four times to enter number 1 21 Enter alpha numerical value N ea 22 To start the alpha numerical input for the highlighted value Meas Measure amp Record y Point Id 1210 Refl Ht 1 650 m gt rus LLON NUN i Insert mode ON OFF Low case High case The cursor is positioned at the end of the value to be edited Use the key E to H to enter alphanumeric characters To
26. f operation Here Press function key labelled NEW J Getting started Instrument description 1 Carrying handle 2 Optical sight 3 Telescope with integrated EDM ATR EGL and PowerSearch 4 EGL flashing diode yellow 5 EGL flashing diode red 6 Coaxial optics for angle and distance measurement Exit port of red laser beam only R model instruments 7 PowerSearch 8 Vertical drive screw 9 Focusing ring 10 Memory card housing 11 Horizontal drive screw 12 Footscrew tribrach 13 Display 14 Tribrach securing knob 15 Keyboard 16 Batteryholder 17 Battery 18 Bull s eye bubble 19 Laser emission indicator lamp yellow only XR instruments 20 Exchangeable eyepiece 10 11 12 13 14 1100201 Inserting replacing battery m Insert battery correctly note pole markings on the inside of the battery cover Check and insert battery holder true to side into the housing 1100Z50 1100248 1 Remove battery holder 3 Insert battery into battery holder 1100249 1100212 2 Remove battery and replace 4 Insert battery holder into instrument Center and level To center and level your instrument activate the electronic level dialog MAIN MAIN MENU Ca e SAIET ELECT LEVEL CH Tilt L 0 0004 g E Tilt T 0 0012 g oO N S L Plummet 50 V LONT ooo o ERE O Lase
27. i couglisi AIN Codelist Selection A J EEA S CEM fp Name of the new codelist Name Vegetation Device A Internal Y EN Enter the name of the new codelist Enter the device to record the codelist i the internal memory of the TPS1100 instrument PC Card to record the codelist on the PC Card ils To create the codelist and continue to the Codelist selection dialog MAIN Codelist Selection lt m f Surveying PC Card Vegetation 81 Call the Edit function from the codelist selection dialog to display 82 Define new codes the list of codes for the selected codelist MAIN Codelist Selection lt a a CLIST Vegetation corner ii pea To add new codes to the list ICLIST Enter new code Code f 12 Code Descr Tree o E a E y Enter the code data Code Code to be recorded in the measurement job Alphanumeric values are accepted Code Descr Description of the code optional This information will not be recorded in the measurement job Define Info s for the new code To define additional code Infos Note you can define up to eight code Infos CLIST Enter new code iw B Code Code Descr TE You can overwrite the default text Info 1 e g for the code Tree the information Diameter might be needed To create the new code and display the new content of the codelist CEIST Vegetation o a TET Symbol for
28. ion Setup Shifted function Job Settings Electronic level display REDL Set station orientation Laser plummet On Off L PI given the azimuth STN Set station orientation to one backsight QSET Program selection TPS1100 Program list 1 PPM Definition 2 Reflector Selection RCS functions not for all 3 EDM program selection instrument types 4 Check Orientation Compass positioning COMPS 5 Data View and Edit PowerSearch PS 6 Job settings HZIV positioning HZIV 7 Increment amp Offset Joystick positioning JSTCK 8 EDM Test signal freq Define Working Area WORKA 9 Compensator Working Area On Off WORK ATR functions Turntolast REC point LAST ATR On Off ATR RCS On Off RCS Lock mode On Off LOCK Lock Interrupt L INT IR RL gt REF gt RL Standard Tracking gt STD gt TRK FAST Rapid Tracking gt FAST gt RTRK 103 Configuration functions Communication Mode GSI Parameters GeoCOM Parameters GeoCOM On Line RCS Parameters RCS On Off ee E 3 PC Card ESO Configuration y 1 Instrument Config 2 Communication mode 4 Load Check PC Card Format PC Card Load user configuration from card Load system parameters from PC Card Save current system parameters to PC Card SAVE Load Application Load system language 104 Instrument Config 01 02 03 04 05 06 Units Decimals and V angle displa
29. ion to a target without prism you first need to switch ATR off 55 LOCK mode Call the FNC fixed key from any dialog to switch the LOCK mode 56 on FNC C E s 1 PPM Definition 2 Reflector Selection 3 EDM program selection ON gt 4 Check Orientation 5 Data view and edit OFF no icon 6 Job settings A EULA LOCK A E FAST 1 Step Activate LOCK mode To switch LOCK on and return to the previous dialog The icon confirms that LOCK is on but the instrument is not tracking the prism yet 2 Step LOCK to stable prism ALL o DIST Approximately aim at the prism Note that the prism has to be stable and must not move To trigger a distance measurement Once the icon P is displayed the instrument is locked to the prism The rod person can move and the instrument will follow the prism 57 2 Step LOCK to unstable prism FNC L GO This functionality is helpful to lock to a prism located on an 58 unstable surface e g on a boat or near to the instrument Aim at the prism and make sure that it is visible within the field of view of the telescope To call the function selection dialog iw B 1 PPM Definition 2 Reflector Selection 3 EDM program selection 4 Check Orientation 5 Data view and edit 6 Job settings F LOCK L GO _ gt TRK_ gt FAST To activate prism tracking and
30. is possible anytime To set the EDM program to be used when triggering a distance with the functions DIST or ALL call the N fixed key FNG f Function selection y el iw E K Set EDM Prog For DIST ALL Target Typ Reflector w EDM Prog Standard v Refl list Leica circ prism w Add Const 0 0 mm a E E i You can also call this function from the Distance Measure dialog after having triggered a distance measurement 47 Parameter description Target Type Reflectorless Reflector EDM Prog Standard Fast Tracking Selection of the target type only on instruments with the option reflectorless EDM For reflectorless distance measurement The Target type must be set to Reflectorless for distance measurements to targets without prism or reflective tape For distance measurement to the selected reflector me The target type must be set to reflector for normal and long range distance measurement Selection of the EDM measurement program for the functions DIST and ALL Standard single distance measurement Fast single distance measurement Continuous distance measurement The measured distances can be recorded anytime with the REC function key Parameter description continued EDM Prog continued Rapid Tracking Average Standard Long Average Long AVG n max Refl Name Continuous fast dista
31. layed in the source file choicelist in the File Selection dialog Coord Order This parameter must correspond to the coordinate sequence in the source file Header lines Number of header lines in the source file The header lines are ignored during conversion 85 Ly Set the output file parameters 86 Coord Order Default extens Entry of the output file extension t If the output format is GSI the extension must be GSI for further use of the converted file on the instrument Selection of the coordinate sequence in the output file Separator Decimals Selection of the field separator from the choicelist parameter available only for ASCII output format Selection of the number of decimals for the coordinate output Ka To accept the settings and return to the File selection dialog Standard Coding The TPS1100 keyboard is equipped with a coding key O F With the coding key you can enter codes plus up to eight additional informations from the following dialogs from the main measurement dialog from the measurement dialogs of all TPS1100 application programs e from the station setup dialogs The codes and informations are recorded independently of the measurement data You may record the code before or after you have measured and recorded the target point data The standard use of the coding key allows the manual entry of codes and informations You can selec
32. nce measurement The measured distances can be recorded anytime with the REC function key Average mode For long range distance up to 5000 meters or more Instruments with the option reflectorless EDM only Average mode for long range distance measurements Instruments with the option reflectorless EDM only This parameter is displayed only if an averaging EDM program has been selected Input field for the maximum number of distances to be averaged from 2 to 999 distances This parameter is displayed only if the target type is set to Reflector Selection of the reflector from the list 49 Shortcut for switching between EDM programs Switch between reflector and reflectorless Following functions allow to change the EDM program for a single 50 distance measurement quickly with two keystrokes For instance if you are measuring distances with the standard EDM program and you want to measure a single reflectorless distance To switch from measurement to a reflector to reflectorless distance measurement TCR and TCRA only To switch from reflectorless to distance measurement to a reflector TCR and TCRA only Switch from single to tracking To start distance tracking To start standard distance measurement To start rapid distance tracking To start rapid distance measurement 51 Measure and record in tracking mode When the instrument is tracking distances you can edit
33. o Working Area y current Hz left 144 g Hz right 185 g V upper 86 g V lower 115 g PCONT DEF CENTR SHOW ES E E E E To define a new Working Area by pointing the telescope to the two opposite corners of a rectangular area To position the telescope to the upper left lower right corner of the defined Working Area To centre the working area to the current telescope position retains the same size of the WA To confirm the displayed values and return to the previous dialog Communication settings If you have communication problems check the RCS communication parameters set on your instrument see chapter Instrument map Configuration and on your RCS1100 controller see following chapter Functions behind the FNC key They must correspond to those for the TCPS26 which were set in the factory to the following values e 19200 baud 8 data bits e No parity 69 RCS1100 local functions Functions status gt 2 sec CONT The RCS1100 local functions allow to set the local parameters of 70 the RCS1100 controller and radio modems Press down the illumination key for more then two seconds until the dialog RCS Status Local is displayed RCS Status Local W Batt RCS 4M Radio ll r This dialog allows to check or set following parameters e RCS controller battery e Quality of the radio link Contrast of the controller display e Illumin
34. oint coordinates Disp Mask Selection of the display mask for the measurement dialog REC Mask Selection of the GSI recording mask Exit after job settings ma To confirm the job settings and continue to the measurement dialog Station setup functions The setup procedure offers two different functions for station setup and orientation 1 For station setup and orientation by known azimuth 2 For station setup and orientation to a known backsight point E In both functions the orientation is performed to one point You can use the TPS1100 program Orientation and Height Transfer to set the orientation from measurements to 1 to 10 tie points 29 Station setup and This function is used for station setup and instrument orientation orientation by given azimuth given the station coordinates and the azimut to a backsight point Station data Call the Station function from the Job Settings dialog AIN Job Settings LAB o SIN MAIN Enter Station Data y Station Id ST1 Inst Ht 1 600 mi Stn East 0 000 m Stn North 0 000 m Stn Elev 0 000 m Hz A 12 1300 g CONT EAA a To import station coordinates from data job l Enter the Station Id and the instrument height You can enter the station coordinates manually or import them from the data job 30 Orientation 1100QS06 CONT Call the dialog for setting the instrument orientation Set Hz direction Hz z
35. or Selection EW Select reflector type Refl list Leica circ prism Y Add const 0 0 mm DEF 1 2 3 for new reflector Le A 3 To define a new reflector the reflector name and addition constant can be defined Select the reflector from the choicelist The addition constant of the reflector is displayd as information To accept the selection and return to the dialog from which FNC has been started EDM Program selection N N CONT Call the dialog for EDM program selection from the function selection dialog FNC Function selection ell FNC EDM Parameters Al B Set EDM Prog for DIST ALL Target Typ Reflector V EDM Prog Standard Y Refl list Leica circ prism V Add const 0 0 mm O E E E Select the target type This function is only available on instruments with the option reflectorless EDM Select corresponding EDM program Standard or Fast distance measurement Tracking or Rapid Tracking Average the parameter AVG n max allows you to set the maximal number of distances to be averaged from 2 to 999 distances To accept the selection and return the dialog from which FNC has been started For more details refer to the chapter EDM functions 39 The Check Orientation dialog allows to check the orientation to a 40 Check Orientation aan known backsight point and to reset the orientation if necessary FNC Function selection m
36. or TPS1100 instruments with Refelctorless EDM Intensity settings You can define the intensity for the following parameters e Display contrast e Reticule illumination EGL guide light iw E Display v Heating X Contrast Reticule EGL Red Laser LOK DISP To modify the intensity position the cursor bar on the corresponding field with the Ae arrow keys and select the desired intensity with the E E arrow keys Ka To confirm the settings and return to the previous dialog 27 Setup Measure and Record The Setup procedure is used to define the job settings and to setup Setup and orient the instrument on a known station m To setup the instrument on an unknown station you can use the TPS1100 programs Resection or Free Station explained in the Applications Program Field Manual The job settings can be defined independantly of the setup procedure with the function Job settings from the FNC fixed function key see chapter FNC fixed function key Start the setup procedure from the main menu T o SETUP aoe Job Settings iw B Meas Job DEFAULT GSI Y Data Job DEFAULT GSI vil Codelist 2 v Disp1l Mask Polar REC Mask v 4 SC S e a Aa To define a new MeasJob Job Settings Meas Job Selection of the job for recording measurements Data Job Selection of the job containing the fix p
37. point Id 52 Reflector Height enter codes and record measurement data as usual MEAS Measurement amp Record EW Point Id 43 Refl Ht 1 750 m Horiz Dist 45 453 m Dns panna REC L TEST STOP n H To record displayed measurement data according to the active REC mask EMM To stop tracking Introduction ATR Functions Automatic Target Recognition ATR is a feature of TCA and TCRA instruments ATR allows automatic angle and distance measurements to prisms The prism is approximatively targeted with the optical sight on top of the telescope No focussing is needed Initiating a distance measurement with ALL or DIST will automatically position the instrument to the prism centre The accuracy of ATR measurements depends on the EDM measurement program set Highest accuracy is achieved with the EDM measurement program Standard Refer to the TPS1100 User Manual chapter Technical Data for more details concerning ATR accuracy As for all other instrument errors the ATR collimation error em can be checked and determined using the calibration function as described in the TPS1100 User Manual 53 ATR operating modes ATR mode FNC Measure with ATR TCA TCRA instruments can be used in two main operating modes 54 e ATR mode automatic measurements to static prisms e LOCK mode automatic measurements to moving prism The instrument follows the moving prism Call th
38. r Plummet ON OFF 1 Center the instrument using the laser plummet a red laser dot is projected on the ground 2 Level up using the footscrews m With the electronic level you don t need to turn the instrument through 90 180 O Repeat 1 and 2 until instrument is centered and leveled CONT To continue 8 Measuring angle and distances 1100QS02 1100QS03 Main Main menu AS B ae MEAS Measurement amp Record EW Point Id Refl Ht Hz gt O gt p gt Horiz Dist Elev Diff 222 3444 82 3467 14 235 0 271 123 B 1 700 Sdi jx Trigger distance measurement a Set Hz orientation Elements of measurement 10 Hz Horizontal angle V Vertical angle Reflector height Height difference Instrument height 1100QS04 Measuring angles and distances separately 1000QS36 1000QS37 Measuring to inaccessible points MEAS Measurement amp Record im Point Id Refl Ht Hz v 5 Horiz Dist Elev Diff Ila 763 222 344 82 3467 14 235 0 271 sog B at DIST REC SetHz gt DISP MSIE Triggers distance measurement The vertical angle is retained after the distance measurement You can now determine the Hz angle of the inaccessible point MEAS Measurement amp Record ja Point Id Refl H
39. return to the previous dialog The icon indicates that the instrument is locked to the prism The rod person can move and the instrument will follow the prism Measure with ATR in Lock Mode FNC DIST Once the TC R A is locked to the prism you can measure and record data with the usual measurement functions The instrument will follow the prism and position itself to the prism centre everytime you trigger a distance measurement If you want to have a realtime display of the distance betweeen the TC R A and the moving prism you can start the distance tracking program as explained below C B Point Id 123 Refl Ht 1 700 m Hz z 222 3444 g v 82 3467 g Horiz Dist m Elev Diff m PALL DIST REC i SetHz gt DISP To call the function selection dialog Press F5 to switch to the distance tracking mode To trigger the distance measurement If the EDM Measurement Program is already set to Tracking or Rapid Tracking you must only press F2 59 Meas Measure amp Record D 60 Point Id 123 Refl Ht 1 700 m Horiz Dist 45 453 m n annan a REC J TEST STOP H To record displayed measurement data according to the active REC mask STOP Tire stop tracking Loss of Target Lock If the instrument looses lock to the prism the icon to is displayed A beep signal indicates if the prism has not been
40. st be identified with short cuts to work with Quick Coding The short cut is a number with one or two digits which is clearly associated to one code Typing the short cut number on the numeric keypad will start the Quick Coding sequence e ALL to simultaneously measure a distance and record a measurement block e CODE to select the corresponding code from the codelist and record a code block You can configure the quick coding sequence to your needs ALL CODE to record the measurement data first CODE ALL to record the code data first Switch ON and measure with Quick Coding You can switch ON OFF the Quick Code function in the measurement dialog Meas Measurement amp Record aa Point Id 112 Refl Ht 1 65 m Hz A 100 5463 g v g 99 8889 g Horiz Dist m Elev Diff lt m ALL DIST REC QCOD HZ0 Dor To switch ON Quick Coding The symbol C is displayed as long Quick Coding is switched ON The function is visible only if a codelist with short cuts have been selected Enter the short cut number on the numeric keypad to start the combined ALL CODE sequence You can use all functions keys available in the measurement dialog while Quick Coding is active You can edit values e g Point Id You need to position first the cursor bar with the up down arrow keys then press led to start the edit mode for the highlighted value 93 Access the Quick Coding config
41. t Hz v 8 Horiz Dist Elev Diff 1 703 222 544 82 3467 14 235 0 271 3 3 QQ53 g ate DIST REC SetHz gt DISP mea Record the displayed measurements 11 Display keyboard Heading Dialog area Function key assignment Cursor bar Illumination Electronic bubble E Operating concept Battery icon Status icons Input keys 1100QS05 Application Additional Running Control programs functions info bar keys gt always accessible The running info bar indicates that additional information is available in the active dialog ON OFF Function keys SHIFT SHIFT Quit Escape SHIFT sc Control keys SHIFT SHIFT e E Sy To switch the instrument ON To switch the instrument OFF first press both keys simultaneously and then press RE Dialog dependent function keys Assignment is indicated in reverse mode in the bottom line of the display SHIFT Second level of function keys Pressing on assignment of the keys changes the To quit the active function or program Available in all dialogs To return to previous display Values altered in dialog are not accepted To scroll through the dialog line by line and to set the cursor bar To display the previous or next page of the active dialog 13 Fixed key concept ICODE
42. t a codelist to be used with the coding key Codelists can be created On the instrument basic functionality e With the PC software Codelist Manager Please refer to the on line help of the Leica SurveyOffice Software for more information 87 Manual code entry Press the code key before or after you have measured and 88 recorded the target point data CODE fg EAS Measurement amp Record Iw __ el C E Code eC Info Be i Info2 waee05 Info Info Info5 wa 05 a e an akhwn To recall the last entered code and Info s y Enter the code In addition you may enter up to 8 Infos to the code ea To record code and Infos in the active measurement job m Code and Infos are recorded in a GSI code block as WI41 WI49 Standard Coding witha For coding with a codelist you must have selected a codelist ina previous step during the setup procedure or in the codelist codelist management function Measurement amp Record EW CODE House Corner Pit Electricity Pole REC NEW LAST Ee a wi Code search settings PX alpha numerical search numerical code search lt Enter the code to be searched for in the title bar e g 12 The cursor bar will be positioned automatically on the corresponding code You can also step through the list with the UP DOWN keys after having exited the search
43. ta jobs e View the job content Search for point or code data in the job e Edit Point Id and codes Input new coordinates m The maximal number of jobs is 60 The Codelist management function allow to Select a codelist from the PC card and internal memory e Create a new codelist e Add code and Info s to an existing codelist E The maximal number of codelist is 32 A codelist can contain up to 500 codes n Note that the Meas Data job or codelist selection can also be done in the Job settings dialog which is part of the Setup procedure Data Conversion allows to convert coordinates available in ASCII format on the PC Card to GSI format and vice versa Configuration gives access to all TPS1100 configuration parameters Refer to chapter Instrument map for a description of the configuration functions Instrument calibration allows to check and determine the instrument errors Compensator V index Line of sight Tilting axis and ATR collimation It is explained in detail in the TPS1100 User Manual 73 The Meas job management allows the selection of the 74 Meas job management measurement job for recording measurement and coding data Call the Meas job management from the Main Menu MAIN Main Menu AB oO Main Selection lt gt fy E Meas Job DEFAULT GST CONT NEW PT EDIT DEL GNUM Select the measurement job Default GSI for recording data or any o
44. the coordinates for the highlighted value To measure a distance to the backsight and check the difference AHorizDist between measured and computed distance To record the measurements to the backsight point EE Instrument not yet orientated To proceed to the next dialog without recording the measurements Set Station with REC or CONT l m ee To record station data and backsight point Id Sets station and orientation and continues to the Measurement dialog To set station and orientation and continue to the Measurement dialog 33 Measure and record ALL key ALL REC key ca DIST and REC DIST combination a The dialog Measurement amp Record can be called directly from the 34 main menu or is displayed after the setup procedure MEAS Measurement amp Record EW Point Id 123 Refl Ht 1 700 mi Hz 222 3444 g Vv 82 3467 g Horiz Dist m Elev Diff j m A PALL DIST REC n SEtHZ gt DISP Angles and distances can be measured and recorded with the following measurement functions One keystroke for measuring angles and distance and for recording measurement data according to the selected REC mask To record displayed angles according to the selected REC mask To measure a distance and to display the measured distance To record displayed distance and angles according to the selected REC mask Utility functions SHIFT
45. the instrument After a few seconds the display of the TCA appears on the RCS1100 For a complete description of the RCS1100 Controller and the RCS operation functions please refer to the RCS1100 RCS1100 User Manual Controller Measure with RCS Lock the TCA TCRA to the prism RCS With the RCS1100 controller you can use the instrument measurement functions as if you were using the instrument itself 1 Free Station Ae Program selection LA MAEA LZ V D L VORKA D CUIT Switch on RCS mode Once the RCS mode has been activated the lock mode on instruments with ATR is switched on automatically but the instrument is not locked to the prism yet If you are at the station you can manually aim to the prism and trigger a distance measurement with DIST The icon displayed as soon as the instrument is locked to the prism p is If you are at the reflector pole several search modes are available to lock the instrument to the prism Call the PROG fixed key to access the RCS search modes 65 66 To start the compass mode You need a compass to use this search mode Refer to the RCS User Manual for more information Starts the quick prism search PowerSearch only available on instruments with optional PowerSearch module To position the motorized instruments to the prism with the cursor keys joystick mode The left right cursor keys move the instrument horizontally The
46. ther job available on your PC Card Eg Select RS232 to record data via serial port RS232 to an external data collector MUE To select the Meas job ca To create a new Meas job EAE To search for point or code data and to view the job content To delete the selected Meas job Data job management CONT EDIT EEE Y The Data job is a job containing fixed point coordinates to be used within stakeout or any other program The data job must be on the PC Card in the GSI directory Call the Data job management from the Main Menu MAIN Main Menu LM jo MAIN Selection lt gt erat Data Job DEFAULT GSI gt CONT NEW EDIT DEL oNUM Select the Data job The Meas job and the Data job can be the same In this case TPS1100 programs will automatically retrieve the first recorded coordinates of the specified point Id To select the Data job To create a new Data job To search for point or code data and to view the job content To delete the selected Data job 75 The functions explained in this section are available in the Meas 76 Meas Data job management job and Data job management functions Call the New function from the job selection dialog MAIN Selection lt gt fy if M JOB Create new job m jS Device PC Card REC format GSI Job name Survey1 Create new job LE a a A oy Enter the name of the Meas or Data job hE To
47. up down cursor keys move the instrument vertically The instrument can be moved faster by pressing a cursor key twice three different speeds It can be stopped by pressing any other cursor key Confirming with starts to search for the prism and locks if the prism has been found SHIFT To position the instrument to the prism by entering angle values e Motorized instruments turn by the corresponding values Confirming with gTa starts to search for the prism and locks ifthe prism has been found Automatic reflector search The RCS searching window is rectangular default Hz 30gon V 15gon If the reflector is found the icon 6 is displayed The dimensions of the RCS search window can be defined in the instrument configuration see function RCS Searching Window in chapter Instrument map In RCS mode it is possible to define a rectangular working area within which the instrument searches for the reflector if the reflector was not found by the default search methods Press the PROG fixed key to access the RCS related functions Ti Program selection W Working Area FROG 1 Free Station CAE N SFNT M A T ee E i Activate Deactivate Working Area To activate the defined Working Area PORK To deactivate the defined Working Area 67 Define a new Working Area SHIFT ENTR 68 To display the current settings of the Working Area S
48. uration settings from the 94 main menu T a o nel Conf Configuration y e F Conf Instrument Config W Q Conf Point and Meas Param mp Increment Quick Coding settings Quick Code REC before ALL Y Quick Code with one digit Y Recording sequence REC before Code block recorded before measurement ALL block REC after ALL Code block recorded after measurement block Short Cut number of digits with one digit Enter a short cut number with one digit to start the Quick Coding sequence with two digit Enter a short cut number with two digits to start the Quick Coding sequence mw For short cuts with one digit e g 7 you must first enter a zero then the corresponding digit to start the Quick Coding sequence e g 07 Point Coding Point coding allows to record point related codes with up to eight attributes The input of point codes is possible in the following dialogs e in the main measurement dialog if point code and attributes have been defined in the display mask in the measurement dialog of some of the TPS1100 application programs The programs must be configured to use the user display mask and the display mask must contain point code and attributes The point codes and attributes are recorded together with the target point data with the function keys REC or ALL Note point code and attributes will be recorded only if defined so in the REC Mask
49. y Reflector selection Definition of new reflectors DEF1 DEF2 DEF3 EDM program selection switch reflector to reflectorless Power On Power Off Autoexec mode Display and Record Define Display Mask DMask Define Recording Mask RMask PPM entry Point amp Meas Param Pt ld mode Increment Offset mode Quick Code settings Info Attribute entry Auto Dist Instrument Config continued 07 08 09 10 11 12 13 Date and Time RCS Searching Window Beep Hz sector Compensator Compensator On Off Hz corrections On Off Hz System and Face Alpha Input mode Delay for character input Language The configuration parameters are explained in detail in the TPS1100 User Manual 105 Leica Geosystems AG Heerbrugg Switzerland has heen certified as being equipped with a quality system which meets the International Standards of Quality Management and Quality Systems ISO standard 9001 and Environmental Management Systems ISO standard 14001 710489 2 2 0en Printed in Switzerland Copyright Leica Geosystems AG Heerbrugg Switzerland 2002 Original text Total Quality Management Our commitment to total customer satisfaction ISO 9001 1SO 14001 Ask your local Leica Geosystems agent for more information about our TOM program e feica Geosystems Leica Geosystems AG CH 9435 Heerbrugg Switzerland Phone 41 71 727 31 31 Fax 41 71 727 46 73 www leica geosystems
Download Pdf Manuals
Related Search
Related Contents
MA8/2 CL monitor activo manual de instrucciones ML・ー00 明 Kensington SP45 Classic Laptop Case - 17"/43.2cm dreamGEAR 10 In 1 Starter Kit f/ DSi 取扱説明書 - LEDIUS商品データベース DA 75 udskiftnings manual type 2 Frigidaire 1500 Series Dishwasher User Manual manual de instalación aplicación polla mateista Copyright © All rights reserved.