Contents

1. days If this function is OFF CO2 monitor will not be calibrated automatically Specifications Method Dual Beam NDIR Non dispersive Infrared Display LCD Independent CO2 Temperature readings Sample Method Diffusion CO2 amp Temperature Specification CO2 Specification Measurement Range 0 3 000ppm display Display Resolution 1ppm at 0 1 000ppm 10ppm at 1 001 3 000ppm Accuracy 0 2 000ppm 100ppm or 7 of reading whichever is greater over 2000ppm 10 Repeatability 20 ppm Temperature Dependence Typ 0 3 of reading per C or 4 ppm per C whichever is greater referenced to 25 C Response Time About 2 min for 63 of step change Warm Up Time About 60 seconds Zone LED Display Green lt 800ppm Yellow 800 1200ppm Red gt 1200ppm 800ppm is the default AL1 1200ppm is the default AL2 Temperature Specification Temperature Range 0 C to 50 C 32 F to 122 F display Display Resolution 0 1 C 0 1 F Display Options C F switchable Accuracy 1 5 C 2 F Response Time 20 30min device must equilibrate with environment Operating Conditions Operating Temperature 0 C to 50 C 32 F to 122 F Storage Conditions Storage Temperature 10 C to 60 C 14 F to 140 F Power Supply Power Supply ace or 5 VDC from external AC DC adapter which is not included in package Please use Standard USB power output range 5VDC 300mA Note CO2 monitor Power consumption
2. until the ALARM 2 icon appears 2 Press Enter Using the Mode to set the parameter the default ALARM 2 is 500 3000 ppm 3 Press Enter again to save the data Note 1 When CO2 Alarm level is 21 000 ppm the interval is 100ppm when the CO2 Alarm level is lt 1 000 ppm the interval is 50 ppm 2 After setting with new alarm level parameter the green LED will light when CO2 concentration below the alarm1 level The red LED will light when CO2 concentration exceeds the alarm 2 level the yellow LED will light when CO2 concentration is between the alarm1 level and the alarm 2 level Using the RcFS Mode _rcFS mo _ YES 1 Press Mode until the RcFS icon appears 2 Press Enter the icon no shows on the LCD Press the Mode to select the no yes 3 After selecting press Enter to save the setting Note If the user sets the data or calibrates the RAD 0301 incorrectly use the RcFS recover the factory Setting to return the unit to the default factory setting Using the 8BC calibration Mode Bbc l on J L__onE J __o FF 1 Press Mode until the 8BC icon appears 2 Press Enter the icon on shows on the LCD press Mode to select on once or off 3 After selecting press Enter to save the setting Note If this function is ON CO2 monitor will be calibrated automatically every 8 days If this function is ONCE CO2 monitor will be calibrated one time in 8
3. 2 2356 f CO2 Measurement Specialists e re manele Sales CO2Meter com
4. CO2mini CO2 Monitor User Manual Product Overview Thank you for selecting the CO2mini model RAD 0301 desktop CO2 monitor This is a smart compact and easy to use mini desktop unit In addition to measuring the CO2 concentration the CO2mini also measures the ambient temperature This product is developed to detect the presence of CO2 in ambient air to monitor Indoor Air Quality and can be widely used in offices schools meeting rooms homes and other places where personal comfort and health is important 1 LCD Display Features 2 Calibration Gas Entry MI Three different LED display shows the current Indoor Air Quality 3 Power Inlet MI It uses dual beam NDIR technology to improve the long term stability 4 Ventilation Slots MI Amini desktop CO2 Monitor 5 Red LED Display gt 1200ppm M Alarm Level can be adjusted by user 6 Yellow LED Display 800 1200ppm 7 Green LED Display lt 800ppm Warnings 8 Mode Key M This CO2 monitor is for home use but is not suitable for certifying the test results 9 Enter Key WI Please use standard USB power such as USB port from PC port from general AC adapter to avoid damaging the unit 000 e gt 550 Mode Enter oooo0o00000000000000000000000 ooo0o0000 o oooo0o00000000000000000000000000000 ooooo0o0000000000000000000000000 ooooooo0o000000000000000000000000 A EMCIRFI Readings may be affected if the unit is operated within radio frequency electromagnetic fi
5. eld strength of approximately 3 volts per meter but the performance of the instrument will not be permanently affected Mode Functions There are several Modes which can be adjusted by user These modes are ALTI Mode ALARM 1 Mode ALARM 2 Mode RcFS Mode and 8BC Mode Compensate the pressure changes with appropriate I The first alarm level can be ALTI altitude of location when ALt ALARM 1 adjusted by user RL I measure The second alarm level f Recover the factory setting ALARM 2 can be adjusted by user ALe ReFS to cancel customize setting rcF5 8BC This function means CO2 monitor can be calibrated automatically in 8 days Oh c Caring for product To ensure you receive the maximum benefit from using this product please observe the follow guidelines 1 Cleaning Disconnect the power before cleaning Use a damp cloth Do not use liquid cleaning agents such as benzene thinners or aerosols 2 Repair Do not attempt to repair the product or modify the circuitry yourself Please contact with the local dealer or a qualified repairman if the product needs servicing 3 Air diffusion The ventilation slots on the housing are designed for CO2 diffusion and should not be blocked Customize Settings When the power has been connected the RAD 0301 CO2 monitor will begin to work In order to meet your personal requirements it is advisable to set up the customizing parameters Warm Up It takes app
6. peak current is 200mA Average current is about 20mA Communication interface only for RAD 0301 Version USB 2 0 low speed function os Windows XP Windows7 Weight amp Dimension Weight 2 470zs 0 15lbs 4 57 116 00 7 a F o Mode Enter 1 64 41 72 ooooo0o00000000000000000000000000000000 ooooo0o00000000000000000000000000000000 oooooo0oo0o0000000000000000000000000000000 ooooooooo0o0o000000000000000000000000000 XQ _ Inch mm Fault Codes amp Troubleshooting Guide This section includes a list of Frequently Asked Questions for problems you may encounter with the RAD 0301 CO2 Monitor Fault Icon Description of the fault Suggested Actions E J The ambient temperature has exceeded the operating This error will clear when the temperature returns to the range Err temperature range 0 C to 50 C 32 F to 122 F between 0 C to 50 C 32 F to 122 F i E rr 5 Please power on RAD 0301 again J EEPROM System Problem If the Err5 Err still appears please contact the Service E rr 6 Department for further assistance r E rr g i The voltage of USB power is too low the device does not work This error will clear when user replaces Standard USB power ACERS 131 Business Center Drive Suite A 3 B Ormond Beach FL 32174 DBD C O 2 M ete r Oo m 877 678 4259 Toll Free oon 866 42
7. roximately 60 seconds before WARM UP disappears all MODE functions will not respond during warm up Warm Up Time About 60 seconds 1 About 60 seconds warm up time when first time power 2 The LCD shows 5 digits in accordance with the order of 5 1 during warm up 3 The device shows the CO2 reading after above 5 digits disappear Note The display time of Temp and CO2 15sec 5 sec Temperature C F e e 1G haw Beg 1 Press Enter to select C or F Note Temp C refers to Temperature in Celsius Temp F refers to Temperature in Fahrenheit To change the mode press Enter and wait several seconds Using the ALTI Mode Ale JL LD 1 Press Mode the ALTI icon appears 2 Press Enter adjust altitude step 100m by Mode button 3 Press Enter again to save the data Note Range is 0 9900m Setting the ALARM 1 Level ALE S _ O_O 1 Press Mode until the ALARM 1 icon appears 2 Press Enter Using the Mode to set the parameter the default ALARM 1 is 400 2900 ppm 3 Press Enter again to save the data Note 1 When CO2 Alarm level is 21 000 ppm the interval is 100ppm when the CO2 Alarm level is lt 1 000 ppm the interval is 50 ppm 2 After setting with new alarm level parameter the green LED will light when CO2 concentration below the alarm 1 level Setting the ALARM 2 Level Ale s00 5S0 1 Press Mode

Download Pdf Manuals

image

Related Search

Related Contents

3950_pro_mini_1200_as_de_en 1975KB Nov    .ation Too for a Road- departure Avoidance System  取扱説明書を必ずご参照ください。  Gigaset 5005  H8S, H8/300 Series C/C++ compiler package V.6.00 Release 03  [Synavi-IdF] Lettre d`infor  Université Pierre et Marie Curie Licence de Mathématiques (3`eme  GR-3 Operator`s Manual Digital UHF Radio Addendum  Dell OpenManage Integration for VMware vCenter 2.1 Technical White Paper  