1. DCS 6000 User Manual Digital Conference System EX 6010 Extension Unit Danish Interpretation Systems DIS Danish Interpretation Systems User Manual Copyright 2003 Danish Interpretation Systems No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the publisher Danish Interpretation Systems User Manual List of Contents General guidelines ccsscccssscsssssssssssccsssees 11 Built into 19 Racks sens 11 Max number of units to be connected 12 CM DM 60x0P Chairman Delegate Units 12 CM DM 60x0P Chairman Delegate Units amp JB 6002 Junction Box 12 CM DM 6060F 6510F Chairman Delegate Cleaning amp Repacking esse 4 L TS PR St Een 13 Warranty eseeseseeessoesesceccsoesecoeeoseeseeoesosseseescsoeseeoee 4 CM DM 6560F Chairman Delegate Units 13 MU 6040 C D without connected loudspeaker E EE eae ie cata ne mines Din aka ee 14 IS 6132P Interpreter Units 14 System components cssssccscsccsssscsssssccssessees 6 IS 6132P w JB 6004 and LS 6032 15 Central equipment etc 6 CS 6032F Channel Selector w back light on 15 Interpreter equipment 6 Typical schematics esse 16 Conference equipment and channel selectors 6 Large size conference microphone system 16 Operating instructions Various configurations with RP 6004 Repeater EX 6010 Ex
2. FTP or STP ensuring a very cost effective installation and easy set up of portable systems Firmware in Delegate units Interpreter Units Central Units etc upgradeable through RS232 on Central Unit Can be operated with or without a PC Added functionality and comprehensive features provided by SW 6000 software package running on PC RS232 RS422 connection on CU 6010 for external operation of the system of a PC or control system such as AMX or Crestron The SW 6000 is an optional software package which expands the functionality of the DCS 6000 system The software runs on standard computer technology Standard PC with Windows 2000 or XP Main features of the SW 6000 are e Microphone management e Mimic panel operation e Interpretation management e Voting management e Message handling e Agenda handling e Data stored on SQL data base for easy export import of data as well as easy links to external databases e Multi language user interfaces e Supports different user type with different priorities user interfaces and control possibilities e Variety of printing facilities such as speaker s log voting results delegates list etc Manual 01 18 04438 5 Danish Interpretation Systems User Manual Syst t Conference equipment and channel ystem components selectors The CU 6010 Central Unit supports all available CS 6032FV H units in the DCS 6000 series Channel Selector flush mounted CM DM 6010P Conference
3. Unit portable 7 CM DM 6020P Conference Unit portable with Central equipment etc XLR microphone connector EX 6010 Extension Unit CM DM 6070P Conference Unit portable with PS 6000 Power Supply two built in channel selectors AO 6008 Audio Output box CM DM 6090P Conference Unit portable with RP 6004 Repeater for fois chains two built in channel selectors and XLR microphone connector JB 6002 Junction Box with 2 outputs CM DM 6060F Conference Unit flush mounted JB 6004 Junction Box with 4 outputs with one built in channel selectors Interpreter equipment CM DM 6510F Conference Unit flush mounted ith Chip card and ti IS 6032P Interpreter Set eee LS SD IS 6132P Interpreter Set CM DM 6560F Conference Unit flush mounted LS 6032P Interpreter Loudspeaker with one built in channel selector Chip card and 3 voting buttons MU 6040C D Microphone Unit for use with customised front plate with Loudspeaker Microphone and Buttons Available in Delegate D and Chairman C version AM 6040 Ambient Noise Microphone 6 Manual 01 18 04438 Danish Interpretation Systems User Manual Operating instructions EX 6010 Extension Unit The EX 6010 Extension Unit provides additional Power Supplies Repeater and Splitter functionality for the DCS 6000 system One CU 6010 Central Unit is needed in each DCS 6000 system however for expansion of the system the EX 6010 Extension Unit is suitable The EX 6010 consist of two ma
4. be connected e The max number of languages configured on chain A Al or A2 or B B1 or B2 is 16 If more languages are required Interpreter sets for those languages have to be connected to both chains A and B Normally the languages are supposed to be divided equally on chains A A1 or A2 and B B1 or B2 e Ifthe last unit in one chain is a CS 6032 Channel Selector this unit has to be terminated with an external termination as the CS 6032 does not have an internal auto termination It is desirable that the square of the feeding cables especially but also the interconnection cables are as big as possible to minimize the voltage drop in the cables Cat 5 Cat5E cables are delivered in various gauges The following table is showing the Diameter square for various AWG types Type Diameter Square AWG22 0 64 mm 0 32 mm2 AWG23 1 0 57 mm 0 25 mm2 AWG24 0 53 mm 0 22 mm2 AWG26 0 42 mm 0 14 mm2 Built into 19 Racks The unit has a built in fan taking air in at the right side of the unit and blowing the hot air out at the right side That allows units in 19 racks to be Manual 01 18 04438 stacked close with other units without extra room for cooling air between them Please check that the other units will allow this Danish Interpretation Systems User Manual Max number of units to be connected The following tables show the maximum number of Unit or on each output on an EX 6010 Exte
5. due to the have been connected CU EX but where the total restriction of the maximum length of cable 200 m IS 6132P Interpreter Units This table shows the maximum number of IS 6132P Note The number of units is dependant of how Interpreter Sets which can be connected The many interpreter sets there are per booth or numbers are with no audio in loudspeaker no language as there only can be one set switched ON loudspeaker connected to each unit per language channel If loudspeakers are used then use the figures for CM DM 60x0 above Length of Feeding Cable Length of inter connecting Cables Max number of units pr output Type CATS AWG24 Type CATS AWG24 AlL ON ON 1 3 ON 10m 2m 54 x x 30m 2m 49 57 60 50m 2m 44 SI x 100m 2m 35 40 x 150m 2m 25 30 x 14 Manual 01 18 04438 Danish Interpretation Systems IS 6132P w JB 6004 and LS 6032 User Manual Length of Feeding Cable Length of cable Number of Number of Number of Type CATS AWG24 between booths booths IS 6132 booths LS 6032 booths 10m 5m 19 4 0 10m 5m 12 4 4 30m 5m 17 4 0 30 m 5m 10 4 4 50m 5m 15 4 0 50m 5m 9 4 4 100 m 5m 11 4 0 100 m 5m 7 4 4 150 m 5m 8 4 0 150 m 5m 5 4 4 CS 6032F Channel Selector w back light on Length of Feeding Cable Length of Inter connecting Total cable length Max number of CS 6032 pr Type CAT5 AWG24 cable T
6. lighting constantly Back panel layout FS MANS POWER Repeuted chaina Lii Connectors a Mains Power connector Connection for mains power See specs Q Loop through connectors RJ45 connector 2 pieces with auto termination DCS LAN connectors for connection to the CU 6010 and for connection to other units with DCS LAN connectors such as more EX 6010 Q Repeated Chains 1 2 3 amp 4 RJ45 connector 4 pieces Those connectors are DCS LAN connectors for connection to DM CM 6xxx IS 6132 CS 6032 EX 6010 AO 6008 etc User Manual Please note that the maximum ambient temperature for the CU 6010 is 40 deg Celsius en eciandan parts than ha there proiecton raty have bean GNU Ranae Me caroad or kut Q Power LED s Those LED s light up when Power is available on the connector next to the LED and only if the voltage is over 24V not overloaded Q Incoming data LED s Those LED s lights up when the unit is received in coming data from connected units on the connector next to the LED Q Outgoing data LED This LED lights up when outgoing data is received from the central unit 8 Manual 01 18 04438 Danish Interpretation Systems User Manual System design There are no settings to be done on the EX 6010 Extension Unit However it is important to observe that the unit is only repeating one of the chains on the CU 6010 Central Unit And as so the specification which applie
7. 4 J 7 LE 7 ag 3 2 q a J J a a a J q CATS cable a a 8 RP 6004 ED ________ 9 D 2 EP o tp _ MUGO 1 MUGO MUSO PS 6000 qu 6040 1 MU 6040 roa SS SJ si RP 6004 eee ap ap RP 6004 EX RP 6004 ARE 1 1 I ee RP 8004 id aa RP 6004 ee l Manual 01 18 04438 17 Danish Interpretation Systems Appendix Technical appendix User Manual Cabling CAT5 The DCS 6000 system uses CATS CATSe or CAT6 FTP or STP cables with screened RJ45 connectors EIA 568 B wiring shall be used It is important to use only FTP or STP screened cables and screened RJ45 connectors and not UTP cable which is unscreened How to wire a CATS EIA 568 B Cable Pin Function Connector 1 Connector 2 l 2 3 GRN WHT GRN WHT 4 5 6 7 8 Note If other colour codes are used then the four pairs are connected as follows Pair 1 Pinl amp 2 Pair 2 Pn3 amp 6 Pair3 Pin4 amp 5 Pair 4 Pin7 amp 8 The phase of the pairs must be correct and the wiring spec as stated in CATS EIA 568 B have to be followed Note Cat6 cables can normally only be terminated in sockets female and not in cable plugs Cat6 can thus only be used for longer cable draws terminating in wall outlets or jack patch panels Accessories not supplied Cat 5e Connection Cables AWG24
8. EC 6000 5 Connection Cable 0 5 m 10 03 12500 EC 6000 01 Connection Cable 1m 10 03 13101 EC 6000 02 Connection Cable 2 m 10 03 13201 EC 6000 05 Connection Cable 5m 10 03 13501 EC 6000 10 Connection Cable 10 mu 10 03 14102 EC 6000 20 Connection Cable 20 mu 10 03 14202 EC 6000 50 Connection Cable 50 mu 10 03 14502 18 Manual 01 18 04438 Danish Interpretation Systems User Manual Technical specifications General Power consumption max 600VA In rush current max 30A 115V or max 60A 230V Mains voltage 100 240V 50 60Hz Supply voltage for units each Al A2 B1 B2 48V 100W Max power load on Loop Through connectors 7 5W Temperature to guarantee specified performance A TNT CET ET PEAR 5 Deg C to 40 Deg C 35 to 80 humidity Storage temperature PARTS RTE En PE 20 Deg C to 60 Deg C 10 to 80 humidity dimensions in bracket are including 19 brackets Accessories supplied 0 0 cccceeeeeeteteeeseeeeeeeeeees User manual he eee tree nee Ole ane ete eee est eevee Mains cable A AA E EEE 5 pieces termination plugs Connectors DCS LAN loop through s seesssseeeeeersererrerrereee 2 pieces RJ45 DCS LAN repeated output 4 pieces RJ45 System performance with CU 6010 as central unit Max number of DM CM excl CS 1000 Max number of IS 6x
9. g Cable Length of inter connecting Total cable length Max number of Type CATS AWG24 Cable Type CATS AWG24 CM DM 60x0 pr output 10m lm 39 m 30 30m lm 56m 27 50m lm 73m 24 100 m Im 115m 16 150 m lm 160 m 11 10m 2m 64 m 28 30m 2m 78 m 25 50m 2m 94 m 23 100 m 2m 130 m 16 150 m 2m 170 m 11 CM DM 6560F Chairman Delegate Units Length of Feeding Cable Length of inter connecting Total cable length Max number of CM DM Type CAT5 AWG24 Cable Type CATS AWG24 60x0 pr output 10m lm 35 m 27 30m lm 53m 24 50m lm 70m 21 100 m 1m 113 m 14 150 m lm 159 m 10 10m 2m 58m 25 30m 2m 72m 22 50m 2m 88 m 20 100 m 2m 126 m 14 150 m 2m 166 m 9 Manual 01 18 04438 13 Danish Interpretation Systems User Manual MU 6040 C D without connected loudspeaker This table shows the maximum number of MU loudspeaker connected to each unit If 6040 Microphone Units which can be connected loudspeakers are used then use the figures for The numbers are with no audio in loudspeaker no CM DM 60x0 above Length of Feeding Cable Cable length between Total cable length Max number of Type CATS AWG24 each MU 6040 MU 6040 10m 2m 168 m 80 30 m 2m 178 m 75 50 m 2m 188 m 70 100 m 2m 200 m 202 m 51 52 150 m 2m 200 m 232 m 26 42 100 m lm 151m 52 150 m lm 191m 42 Numbers in are the number of units which could number of units has been lowered
10. he CU 6010 an almost unlimited number of EX 6010 can be connected by using the Loop through connector all However the practical limitation is the maximum cable length in one chain which is 200 m and the supply of power to the Loop Through connectors at the EX 6010 The following schematic is showing the connections using the Loop through connectors A combination of the two methods of connection can be seen in the CU 6010 User Manual 10 Manual 01 18 04438 Danish Interpretation Systems User Manual System Setup General guidelines Connect the EX 6010 to the various DCS 6000 units using Cats or Catse FTP or STP screened cables Maximum cable length in one chain is 200 m before repeating This includes interconnection cables between the units The max usable cable length depends on the units connected and length of feeding cables etc Maximum cable length in one chain when using repeaters is 650 m Although each of the outputs DCS LAN Network Output connectors Al A2 B1 and B2 have a 100W supply this 100W power is not all usable with long cables as there will be a voltage drop in the feeding cable from the EX 6010 to the units connected If the feeding cables are short and the cables between the units are short more units can be connected than if the feeding cable is long and or the cables are long between the units Please consult the next section Max Number of units to
11. in parts e Repeater splitter board with 4 individual outputs e 4 individual power supplies The main features of the EX 6010 Extension Unit are e Built in Power Supplies for app 200 units Delegate or app 600 Channel Selectors e 4 outputs for connection to Delegate Units Interpreter Units etc e Loop through connectors for connection additional EX 6010 or other units which are part of the DCS 6000 system e Delayed switching on of power to the four chains to minimise the total in rush current on the Mains supply e Designed in a standard 2HE 19 cabinet User Controls indications amp connectors Front plate layout Front plate controls The EX 6010 Extension Unit features the following controls and display Q Power Led When power is switched ON at the CU 6010 Central Unit any connected EX 6010 Extension Units will automatically be powered up An LED indicates when power is switched ON Q Fault LED This indication lights up if the internal power supply is malfunctioning i e because of overheating or overload of a chain The Fault LED will always light up some seconds after the unit is switched on caused by the delayed switching on of the four supplies As a warning the light is flashing at an internal temperature above 45 C At a temperature above 55 C or if one of the DCS LAN outputs is Manual 01 18 04438 7 Danish Interpretation Systems supplying no voltage the LED is
12. nsion units which can be connected to each of the four Unit or on the output of a PS 6000 outputs Al A2 B1 or B2 on a CU 6010 Central CM DM 60x0P Chairman Delegate Units Length of Feeding Cable Length of inter connecting Total cable length Max number of CM DM Type CATS AWG24 Cable Type CATS AWG24 60x0 pr output 10m lm Sim 42 30m lm 67m 38 50m Im 83 m 34 100 m 1m 123 m 24 150 m 1m 165 m 16 10m 2m 88 m 40 30 m 2m 98 m 35 50m 2m 108 m 30 100 m 2m 142 m 22 150 m 2m 180 m 16 This configuration shows two CM DM 60x0 6002 Maximum 5 m cable from JB 6002 to Delegate Chairman Units connected to one JB 6002 CM DM 60x0 and max one CM DM 60x0 on each Junction Box with 3m cables between each JB output of JB 6002 Length of Feeding Cable Length of Cable between each Total cable Number of Max number of Type CATS AWG24 JB 6002 Type CATS AWG24 length JB 6002 DM 60x0 10m 3m 61m 18 36 30 m 3m 75 m 16 32 50 m 3m 89 m 14 28 100 m 3m 127 m 10 20 150 m 3m 168 m 7 14 12 Manual 01 18 04438 Danish Interpretation Systems User Manual CM DM 6060F 6510F Chairman Delegate Units The following tables show the maximum number of Unit or on each output on an EX 6010 Extension units which can be connected to each of the four Unit or on the output of a PS 6000 outputs Al A2 B1 or B2 on a CU 6000 Central Length of Feedin
13. oth Stubborn stains may be removed with a cloth lightly dampened with a mild detergent solution Never use organic solvents such as thinners or abrasive cleaners since these will damage the cabinet Save the original shipping cardboard box and packing material they will become handy if you ever have to ship the unit For maximum protection re pack the unit as originally packed from the factory Warranty The unit is minimum covered by 12 months warranty against defects in materials or work manship 4 Manual 01 18 04438 User Manual Danish Interpretation Systems Description of the DCS 6000 system The DCS 6000 system has the following main features Fully digital Excellent sound quality State of the Art fully digital integrated interpretation discussion and voting system offering interpretation language distribution conference microphone and voting facilities with attendance check with Chip Card TM New unique digital DATA and AUDIO bus 39 incoming channels 8 floor channels 31 interpreted channels 33 distributed channel 2 x floor 31 interpreted channels The Delegate and Interpreter units are powered and controlled by the CU 6010 Central Unit which drives up to app 200 units on 4 chains EX 6010 Extension Units or PS 6000 Power Supplies available if more units are required A total of 4000 units delegate or interpreter units can be connected to the system Using screened CATS cabling
14. s to each of the chain outputs on the CU 6010 Central Units does also apply to all the repeated outputs in total So when designing a system to incorporate EX 6010 Extension units bare in mind that as the EX Repeated chain connector CATS cable When connecting the EX 6010 Extension Units to the CU 6010 the first EX is connected to the Loop through connector The next EX 6010 Extension units can be connected to either the other Loop through connector or to one of the Repeated out connectors If using the 6010 Extension Unit is repeating only one of the four outputs A A1 or A2 or B B1 or B2 the max number of languages configured on the four outputs 1 2 3 and 4 is totally max 16 If more languages are required Interpreter sets for those languages have to be connected either to an other EX 6010 Extension Unit which is connected to the other of the two chains A or B on the CU 6010 or directly to the other of the two chains A or B ona CU 6010 Repeated outputs two more EX 6010 Extension units or RP 6004 Repeaters can be connected extending the maximum cable length in one chain up to 650 m The above schematic is showing the connection using the Repeated chains connectors Manual 01 18 04438 9 Danish Interpretation Systems User Manual Loop through connector Floor sound out Sound in When connecting a number of EX 6010 Extension GATS cable Units to t
15. tension Unit me 7 and PS 6000 Power Supply 17 General description 7 Features street ides dette cr es 7 Technical appendix ssccssssscsesssssssssessessessesenes 18 User Controls indications amp connectors 7 Cabling seit 18 System desist tirer eee tye nu 9 Accessories not supplied 18 System Setup Technical specifications 19 Document version Printed 12 10 2004 Revision C Name EX6010 REV C DOC Copyright 2003 Danish Interpretation Systems No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the publisher Danish Interpretation Systems User Manual Compliancy The equipment has been tested and found to comply with the limits of the following standards for digital devices EN55103 1 Emission EN55103 2 Immunity EN60065 safety UL6500 safety FCC rules part 15 class A Emission This device complies with part 15 of the FCC rules Operation is subject to the following conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in residential commercial or light industrial environments The equipment generates uses and can radiate radio frequency energ
16. xx in one booth s s s 32 Max number of IS OXXxX oo cece eceeeeeeeeseeseeseeeeseeeseeeetseeneees 150 Max number of AO 6008 20 Max number of CS 6032 practically unlimited Max number of languages 31 Max number of open microphones 8 Max system performance Max number of units excl CS 4000 Max number of IS 6xxx in one booth sssr 32 Max number of CS 6032 practically unlimited Max number of languages 31 Specifications are subject to change without notice Manual 01 18 04438 19 Danish Interpretation Systems 20 Manual 01 18 04438 User Manual
17. y and if not installed and used in accordance with the user manual it may cause harmful interference to radio communications You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment Check that the voltage of your local power supply is within the operating voltage of the unit 100 240V AC If a voltage conversion is required consult your DIS dealer or qualified personnel Should any liquid or solid object fall into the cabinet unplug the unit and have it checked by qualified personnel before operating it further Set the Power switch to OFF if it is not used for several days The equipment must be connected to earth Installation precautions Allow adequate air circulation to prevent internal heat built up Do not place the unit on a surface rugs blankets etc that may block the ventilation holes Do not install the unit in a location near heat sources such as radiators or air ducts or in a place exposed to direct sunlight excessive dust or humidity mechanical vibration or shock To avoid moisture condensations do not install the unit where the temperature may rise rapidly When installing the unit inside a 19 rack observe that the rack is properly ventilated The maximum allowed temperature inside the rack is 40 C Cleaning amp Repacking To keep the cabinet in its original condition periodically clean it with a soft cl
18. ype CATS AWG24 output 30m lm 139 m 110 50m lm 144 m 95 100 m lm 184 m 85 150 m lm 200 m 51 67 10m 2m 200 m 96 30m 2m 200 m 86 90 50m 2m 200 m 76 85 100 m 2m 200 m 51 70 150 m 2m 200 m 26 60 total number of units has been lowered due to the restriction of the maximum length of cable 200 m Numbers in are the number of units which could have been connected to the CU EX but where the Manual 01 18 04438 15 Danish Interpretation Systems User Manual Typical schematics The following schematics are showing various configurations Large size conference microphone system Ve Sn i i Nas 7 E E e a CM 6010P DM 6010P DM 6010P DM 6010P DM 6010P DM 6010P DM 6010P NET ES RE CM 6010P DM 6010P DM 6010P DM 6010P DM 6010P DM 6010P DM 6010P EX 6010 seg Nae Nae i a UE D T E DM 6010P DM 6010P DM 6010P DM 6010P DM 6010P DM 6010P DM 6010P EX 6010 CATS cable as __ 3 SS lt a5 y gt 14 mm 6 R DM 6010P DM 6010P DM 6010P DM 6010P DM 6010P DM 6010P DM 6010P EX 6010 CATS cable e Da 2 5 ae gt 13 en 9 _ DM 6010P DM 6010P DM 6010P DM 6010P DM 6010P DM 6010P DM 6010P EX 6010 16 Manual 01 18 04438 Danish Interpretation Systems User Manual Various configurations with RP 6004 Repeater and PS 6000 Power Supply Total max lenght 650 m 200 m 200 m 50m E o Se RP 6004 RP 800