USER MANUAL

image

Contents

1. tot Prn report printout without clearing total register tot oFF clearing total register report printout and tot q gt Te leaving the function hy fot working with receipt printout after each v measurement tot working without receipt printout 10 00 GE tot CFG saving measurement mode using EF hy key Manual after taking off the load auto v Press T lt key when fot O is displayed 0 00 Perform measurement series by pressing 5 key for storing results into total register v In order to print and display results enter the function by choosing totAL and tot Prn option from menu 20 00 I v hy 0 00 MENU v l The results are display in the following sequence total weight totAL STE number of registered measurements n average value WwW hy regarding that moving to display successive result is performed after pressin gt key tot Prn gt T i v hs In order to go back to total weighing without zeroing total register press cS key third time 30 00 G v n 2 v 15 00 50 INSTRUCTION MANUAL To leave the function with clearing total register select fotAL function from menu and choose tot oFF option When It will cause the scale prints
2. NET 40 01 gt v 42 31 14 3 Increased readability 2 30 Cree The scale is equipped with tare equal to its range Joint value tare and mass net can not cross a maximum of scale To display gross weight press B G key Note Press B G key to return to net weight indication Press HR key to display the weighing result for 5s with the highest readability possible This function is especially helpful in scales with legal verification with d e The weighing result with increased readability can be used for informational purposes only and cannot be printed or sent to a computer with La key 30 INSTRUCTION MANUAL 15 Special function description All scales besides basic metrological functions weighing and taring have a set of special functions Depending on meter type functions set differs Below a list of functions available in standard ME 01 type meters menu customization function ACtIV removal of all function from menu dEFAUL autozeroing function AutotAr pieces counting function PCS change of mass unit Unit percentage weighing function PErC recipe weighing function rECIPE extended calibration function CALIb selecting label number function LabEL function for setting serial port working Print function for setting serial port SErIAL weighing large animals function
3. A N Keep all dimensions shown in drawings and table Careless and inaccurate foundation preparation may make balance installation impossible or cause its improper operation 18 INSTRUCTION MANUAL Foundation frame with anchors 200 ee ia a Feet under balance legs re PCV pipe for cable Water collector Fig 1 Foundation crosssection Places for frame anchors Area reinforcement bar free Foundation frame with anchors Fig 2 Foundation view from above INSTRUCTION MANUAL 19 8 3 2 Scale installation 1 Balance structure y 2 Screws fixing the limiter go SN OIO gt 1 3 Screws fixing base plates gor 4 Limiter EF 5 Base plate EI Pops Cc 6 Foundation M047 TD lt lt 7 Balance leg 7 eee Prepare the foundation 7 according to guidelines section 6 and engineering technique principles Put the balances base plates 5 freely in the foundation Place limiters plates 4 on plates 5 Connect both plates with M8 screws 2 so they cannot move in respect to each other but to allow for limiters 4 manoeuvring Unscrew screws fixing the balance upper plate Put the balance structure 1 in the foundation so legs 7 fit vertically in the limiters 4 holes Place upper plate on balance structure and lightly screw in the fixing screws Check the upper plate location in the foundation level in relation to foundation edge and distance from the edges fig
4. USER MANUAL 4BA N 4BANA N 4BAF N 4BAPZ N and 4BAPA N SERIES File 2014 03 20 ER 4BAxx bE0069 GB 2 INSTRUCTION MANUAL Table of contents T General description sscan e SR 4 2 EE ea 5 Oe Dompeksvv422r244v FE 7 4 iFechnical data ee oe eaaa aaa a aaaea nE 7 5 Meter ME 01 balance keys and indicators ccesccsecesscsseseeeeesceceesecsseeeesesseeesateeees 10 6 Scale Sxte ial OUEDULS Lasses Aa 12 Ta Safety PINNE EE 14 8 Balance preparation to Wok Lusnsemmsebekeknsuseiv Reoealsstrateseasdsavecsheameasbetladians 15 8 1 Preparing platform pallet and skid scales cccccessesssssssssssssssssseseseeeesesssssseeseees 15 8 2 Preparing overrun seas Rasta eicaatla ceanaiis chandscatateas keg annene nnana 16 8 3 Preparing foundation scales Lavard 17 8 3 1 Pete 17 RS EEE ee EEE E aS 19 BANE vad 21 10 Operation Principle S senera ance ce kerh ee ono a otek ence 8 22 Tiz BR GGER ordtak a 23 12 Accumulator change ME 01 option ccscssssssssssssesssssssssssseessssessssraresereeseses 23 13 Connection with computer printer or label printer ccccccssscsssesseseseeseeeeeeees 24 12 Basic UIO eee 28 14 1 NOMEN isan anenee aaae e eea e aaa 28 14 2 Weighing BevasaassassssdamsaasGaaauLsekgebvsgnskrn 29 14 3 Ineeisedreadabliusansnsnstamudkesekneunasdekuneansepaubndmie 29 15 Special function JESENPUON ass Gerda 30 15 1 Menu customization function ACtIV and dEFAUL ernvnvrvrnrsrersvrvev
5. Operation sequence 0 00 MENU v b thr gt Te v b thr on gt T v b SEt 1 gt t v b Miles SSE v b 5 30 v b 50 MENU h SEt2 100 MENU SEt 3 GTE 5 MENU vg i SEt O gt T v b Press MENU key and choose thr pressing ST lt key The following options are displayed successively thr oFF deactivate the function thr on activate the function thr Prn check last threshold values press EF key several times thr CFG choose Relays socket mode 0 exit to weighing 1 Batching mode 2 Indication mode Choose thr on option using T lt key The following options for entering thresholds are displayed SEt 0 go to weighing with signalling threshold excess SEt 1 set lower threshold value SEt 2 set upper threshold value SEt 3 set zero signalisation threshold Using T lt key select SEt 1 option Set lower threshold value using the following keys 0 lt digit increase Cc decimal point ST move to next digit MENU _ finish Then select SEt 2 option and enter upper threshold value Choosing SEt 0 option will cause starting work with signalisation of exceeding thresholds and zero To change Relays sock
6. 10 g 20202020 20313020 2067 0D 0A P1 50 31 OD 0A 40 INSTRUCTION MANUAL 15 9 Serial port parameters setting SErIAL 0 009 MENU v 6 SENAL gt T v 6 baud gt T v 6 4800 Z 9600 gt Te v b baud out T v 6 0 009 The function allows setting the following communication parameters of serial interface transfer protocol Prot LonG printer computer Eltron label printer baud rate bAud 4800 9600 19200 38400 57600bps number of bits in single char bitS 7 8 parity control PArltY nonE no control Odd nonparity Even parity control scale number in network nr if the scale doesn t work in network the number must be 0 result transmission kind through serial interface SendinG I stb transmission after L key is used and result is stable 1 transmission after L key is pressed without need of stabilisation automatic transmission after load is put on and result is stable Auto continuous transmission about 10 results per second Cont Default parameter values Long 9600 bps 8 bits none Ustb In order to set needed parameters choose Port 1 function select appropriate parameter and press TI key when required option or parameter value is displayed The way of setting baud rate of 9600
7. MENU v lo bal FT v gt lo OFF NZ lb on T v 0 00 Attention Ib bAL function is available only in scales assigned for foreign buyers from countries where English pound is used Ib bAL function enables choosing measurement main unit used for current indications and used by other special functions like tArE function Option functions Ib on Ib English pound lb OFF kg or g dependent on scale type In scales with Ib bAL function the list of available units in Unlt function changes lack of English pound and milligram INSTRUCTION MANUAL 65 16 Maintenance and repairs of small defects 1 The scale should be kept clean 2 Take care that no dirt gets between the platform and the scale base If found any remove the pan lift it up remove dirt and then replace the pan 3 In case of improper operation caused by short lasting power supply decay unplug the scale from the mains and then plug it again after few seconds 4 If the scale is switched on with empty pan and Err b communicate appears the load cell has been mechanically damaged 5 It is forbidden to make any repairs by unauthorised persons 6 To repair the scale please contact our nearest service Error communicates Communicate Possible cause Remedy C 1 6 if displayed more than over 1 min 1 minute contact an authorised selftests failed service unLOAd the scale was switched on w
8. Separate ground connection scales in stainless steel version must be connected using additional conductor Extensometers are connected permanently 14 INSTRUCTION MANUAL 7 Safety principles It is necessary to become familiar with safety principles shown below which are necessary to avoid electric shock and damage of balance or connected devices Repairs and necessary adjustments must be performed by qualified personnel only To avoid fire hazard use only typical supply cable and supply voltage must be consistent with technical data For the balance supply use the socket with protective contact Do not use balance when the cover is removed Do not use balance in explosive atmosphere Do not use balance in locations with high humidity when the cover does not have special protections for N type In case of damage suspicion switch the balance off and do not use it until it is tested in professional service company According to valid regulations regarding natural environment protection do not place used electronic devices in containers with common waste Used balance after operation period may be transferred to units authorized for collection of used electronic equipment or to place of purchase INSTRUCTION MANUAL 15 8 Balance preparation to work 8 1 Preparing platform pallet and skid scales 1 Unpack balance remove protective foils 2 Place b
9. LOC entering tare function fArE maximum value indication function UP force measuring function nEWto anti disturbance filter function FILtEr entering reference zero ZErO setting backlight b LIGht only for scales with LCD statistical calculations StAt paperweight calculation function PAPEr main mass unit change Ib bAL option OCOUCOOOOOOOOOODOOOOOoOOoOoOOoD and functions that require additional equipment to be completely functional option with accumulator supply Setting accumulators charging bAttErY Automatic switching off scale function AutoOFF options with the clock setting current date and time function dAtE total weight function fotAL options with the transoptors connectors checkweighing function thr option with USB function for setting additional serial port SErlAL Port 2 option with radio connection function of choosing communication channel rF Chn User creates his own menu by activating functions in ACtIV function described in chapter 15 1 In scales with LCD display some special functions have additional marks on display and names of some functions are extended INSTRUCTION MANUAL 31 15 1 Menu customization function ACtIV and dEFAUL Among available user functions it is possible to 0 00 MENU select these which should be displayed after hy
10. authorized service company to perform balance adjustment Balance adjustment must be performed by authorized service company only as it is connected with necessity of seals breaching required for warranty purposes 12 Accumulator change ME 01 option 1 Remove screws 11 holding plate 12 remove the plate 2 Take out container with Extensometer accumulators 13 and place 4 AA format accumulators The way of packing accumulators into the container is shown on the figure on the 12V 1 2A left and is also shown on the container RS232C WY 0000 00000 24 INSTRUCTION MANUAL 13 Connection with computer printer or label printer The scale is equipped with RS232C which can be used RS232C i to connect external devices such as computer or a printer When cooperating with computer the scale sends weighing result after initialize signal from computer or after pressing E key on the scale When cooperating with a printer data is send automatically after result stabilisation but next transmission is possible 5V option after removing previously weighted sample RxD receive TxD transmission GND A housing When cooperating with label printer after pressing E gt key the scale sends instructions set for the label printer Label number 0001 hour data if the clock is installed and on and nett weight During transmission LabEL communicate is displayed The way of sending data and
11. bps is shown as example in the pictures on the left setting other parameters is performed similarly In scales with an additional serial port appear Port 1 and Port 2 for the independent setting of both ports INSTRUCTION MANUAL 41 15 10 Printout configuration Print Function is used for printing additional information stored in scale memory weighed product identification data and scale operator inscribed using scale keys and scanner 0 00 Menu v 6 Print PT v HEAGEr pT v On T we OO totAL pT v Om I b out fT v 0 00 The function allows switch on off the following positions on printout HEAdEr header name model and scale number Id OPEr operator code max 6 digits Prn no successive printout number choose this option to zero counter Id Prod product number 13 digits Count counting result totAL result sum APW unitary mass netto net mass tArE current tare value brutto gross mass totAL total mass fotAL function If Id Prod or Id OPEr is chosen it is possible to inscribe quickly their new values with omission of main menu In order to do that hold about 3 seconds MENU key and release when Id Prod or Id OPEr indicates Inscribe new value using keys 30 increasing
12. indicator after using gt T lt key indicator MODE special function on indicator indicator B G gross weight after using TARE function and gt key indicator AUT autotare function on indicator T tare memory function on indicator TOTAL _ special functions indicators FILTER SUM indicator ctn weight result units indications g m2 lb mg indicator PCS pieces counting indicator n measurement quantity indications total function indicator OFF turning off the scale by using 1 0 indicator MIN weighing result under threshold I indicator OK weighing result between threshold I and II indicator MAX weighing result above threshold II indicator BAT wska nik roz adowania baterii indicator A O ACTIV function indicator indicator bar scale load indicator 0 100 12 INSTRUCTION MANUAL Inserting numerical values 0 lt increasing the value of digit Ev dot FT next digit MENU end of inscribing 6 Scale external outputs ME 01 Meter in aluminium housing RS232C RxD receive Extensometer TxD transmission 12V 1 2A WY option P1 threshold I P2 threshold 2 P3 threshold housing ground Feeder Sas oC INSTRUCTION MANUAL 13 ME 01 meter in stainless steel housing RS232C 60 0809 housing 19293940 50 Feeder ground TxD transmission USB option
13. pressing MENU key It allows avoiding displaying v whole list of available functions which makes ACHV operation time longer T hy After switching on ACTIV function a dot is displayed D on the right side to distinguish from regular menu Chosen functions are displayed with a dot on the AUTOTA left side EG Operation sequence shown in the pictures on the left causes adding function for setting serial o o o interface RS232C parameters Port to function menu PCS T In every moment it is possible to restore primary manufacture settings choosing dEFAULt special WwW hy function PCS oFF In order to remove function from menu in the last operation in place of selecting PCS on choose PCS J OFF PCS on pr 32 INSTRUCTION MANUAL 15 2 Autotare function AutotAr 0 01 MENU v 6 AutotA gt Te v Aut OFF Vv Aut on gt Te v AT 9 00 When the function is activated the scale automatically ensures stable zero indication if the pan is empty or if zero indication was acquired by pressing gt T lt key To leave the function press MENU key then with T lt key chose AutotA and Aut oFF Note 1 AUt sign occurs only in scales with LCD display 2 In scales with gt 0 key active function changes name into AutoZE autozeroing and works only when the scales is unbiased INSTRUCTION MANU
14. substrate reinforcing and density is taken by building works designer All dimensions are in millimetres During foundation preparation follow the principles below Foundation and feet under balance legs should be made from concrete Foundation bottom thickness should not be smaller than 100 mm Foundation bottom inclination angle shown in fig 1 on page 8 should be at least 3 Keep the same level for all feet Level the foundation frame keeping perpendicularity of sides and equality of diagonals Diameter of PVC pipe for cables to connection box should be at least 50 mm Keep the area free from reinforcing bars as shown in fig 2 on page 8 Foundation external and internal dimensions proper for various platform dimensions are shown in table below Balance type Platform dimensions Foundation internal Foundation enternal mm dimensions dimensions WxLxH mm WxL mm 4B300FN 800x800 820x820x128 1220x1220 4B300FN 1000x1000 1020x1020x128 1420x1420 4B300FN 1250x1250 1270x1270x128 1670x1670 4B600FN 800x800 820x820x128 1220x1220 4B600FN 1000x1000 1020x1020x128 1420x1420 4B600FN 1250x1250 1270x1270x128 1670x1670 4B1500FN 1250x1250 1270x1270x128 1670x1670 4B1500FN 1500x1500 1520x1520x128 1920x1920 4B2000FN 1250x1250 1270x1270x128 1670x1670 4B2000FN 1500x1500 1520x1520x128 1920x1920 4B3000FN 1500x1500 1520x1520x128 1920x1920 4B3000FN 1500x2000 1520x2020x128 1920x2420
15. the communicate informing about clearing registers The form of receipt after each measurement Date er Time measurement no weight measurement no weight Report form Date Time TOTAL WEIGHT NUMBER OF SAMPLES AVERAGE VALUE Note When the scale doesn t have an internal clock Date and Time do not appear on printout Maximum number of measurements is 99 999 Maximum total load 99 999 000d The weighing unit of the total value from the register Total is the same as the weighing unit stated on the keypad or is 1000 times greater what is signalled by o indicator at the left of the display If the registered value is too big to be displayed E communicate appears on the display If the number of series is too high and cannot be displayed Err1 communicate appears on the display INSTRUCTION MANUAL 51 15 17 Checkweighing function thr This function allows comparing weighing result with two programmed reference values lower and upper threshold Comparison result is signalled with indicators MIN OK MAX and sound signal generated when threshold values are exceeded If comparison result is smaller than lower threshold the scale signals MIN yellow colour between threshold values the scale signals OK green colour with the short sound signal greater than upper threshold the scale signals MAX red colour long sound signal The checkweighing results can be use to con
16. transmission parameters is set using SErIAL special function Set of send data is set using special function Print The following data can be send Header scale type Max d e serial number Operator identification number Successive printout number measurement Identification number or product bar code Number of pcs PCS function only Single detail mass PCS function only Nett weight Tare package mass Gross weight Total mass Total function only If the scale is equipped with two serial joints Print function is set independently for both interfaces Computer must have a special program for cooperation with data from a scale Dedicated programs are also offered by AXIS Except RS232C joint the scale can be equipped with USB or Wi Fi interface Needed controllers and instruction can be found on a CD supplied with Axis scales INSTRUCTION MANUAL 25 Detailed protocol description LonG protocol Communication parameters 8 bits 1 stop bit no parity baud rate 4800bps initialising signal data send order correspond to press gt key Computer Scale S I CR LF 53h 49h ODh OAh Scale gt Computer scale response according to description below 16 bytes Byte 1 sign or space Byte 2 space Byte 3 4 digitorspace Byte 5 9 digit decimal point or space Byte 10 digit Byte 11 space Byte 12 k l c p or space Byte 13 g b t cor Byte 14 space B
17. wait for writing zero to the vw hy scale CAL When LOAD message appears put standard of A mass on the pan Press MENU key CAL on doesn t need pressing MENU key PrESS MENU MENU v b Wait until internal calibration is finished and zero Spk indication is displayed 7 yo LOA m 7 PrESS MENU MENU 7 CCCCC MENU 38 INSTRUCTION MANUAL Sequence of actions during calibration with chosen value of standard of mass gt Te 0 00 MENU v b CALIb gt Te vb CAL StP gt T vb om 7 other v D mi O D rmm 0 lt gt Te BAK lt gt 0 lt O O O MENU 5 Press MENU key to display user functions Press OT key during displaying CALIb Press T lt key during displaying CAL StP Following options will be displayed Pt on calibration with chosen mass value Pt SEP calibration with chosen mass value with confirmation of successive steps using MENU key out out of calibration Press T lt key during displaying othEr Using keys inscribe values of standard of mass 0 lt increasing digit 5 dot T lt next digit MENU end of inscribing Further calibration process instructions are made analogically as mentioned on previous side
18. 0 0 PEr OFF and above 35 in format 100 00 vy PEr on calls The function has the following options hs PEr oFF disable the function v PEr on set current scale indication as 100 50 and activate percentage weighing 100 00 out exit without changing settings v 50 00 Note 1 PEr Err message informs that reference 100 mass is less than 0 51Min or was not defined 2 In scales with LCD display sign is replaced with 36 INSTRUCTION MANUAL 15 6 Recipe weighing function RECIPE B A B C 0 00 MENU v rECIPE gt Te 7z f rEC on v 6 0 11 gt T v 0 00 v 0 12 gt Te v 0 00 v 0 13 gt T v 0 00 v fECIPE gt q EC OFF gt T v 0361 eT This function allows for separate weighing of several ingredients in one container with a possibility of control total weight of all weighed components The function has the following options fEC oFF leave the function with possibility of reading to read total weight rEC on start recipe weighing rEC Con continue previous recipe When preparing a recipe successive ingredients A B C etc are weighed each time starting from zero indication In ord
19. 1 When needed shift the plates 5 or put spacers beneath them made from sheet with dimensions of plate If the position of upper plate is correct carefully remove it to not move plates 5 Check if legs 7 are Straight Carefully remove balance structure 1 from foundation to not move plates 5 Fix plates 5 with supplied screws with steel pins Adjust possible displacements with plates 4 position so legs are located centrally and vertically in plates 4 holes Tightly screw plates 5 and 4 Put balance structure 1 in place Place the upper plate and fix it with screws beginning from holes in the upper plate centre AN Connecting cable must be laid freely 20 INSTRUCTION MANUAL 15 Unpack the balance Attach meter to the wall or desktop choosing one of three methods A X D 16 Connect the supply cable plug to socket with protective contact with unloaded balance which will cause autotests performing and after indication stabilization displaying of sero indication INSTRUCTION MANUAL 21 9 Balance start Connecting of supply plug to socket of 230V 50Hz installation with unloaded balance will cause the following sequence of actions EEEIEE Display test WY Tests of basic electronic subassemblies pe ended with messages C1 C 2 C 6 C 4 ae Displaying of meter type SJ PE 7 g f Displaying of software version V7 b
20. 1 15 18 Function for setting date and time dAtE senenrvrnrnvvovovenrnrsvsvsvovevererenrrenenenerenenennn 54 15 19 Radio communication channel choice function rF CHNn ccssseseseesseeeeeeeeees 55 15 20 Entering reference zero function ZErO ccccssssssssscsssssssssssssseessssrsseserereesans 56 15 21 Setting backlight function b LIGH issue tees ee raotereete inten merle hel ee wae 57 15 22 Charging accumulators function bAttErY option oeevrersrrvrvrverrrrrrrrsrrrrrrsrnennnr 58 15 23 Automatic switching off the scale function AutoOF srvrrsrsvrvrverrrrrrvrrrrrnrsrnennnr 59 15 24 Statistical calculations function StAt eevrvrrrvrrvrrrvrrerrrsrrrrvrvrrererrrrrrnrnrrerenrnnnn 60 15 25 Paperweight calculation PAP asset arene enelatates 63 15 26 Main mass unit change function Ib_DAL Option c ccccesseseseetsesesssesseeeess 64 16 Maintenance and repairs of small defects cccsesssssseeseescsssssseeensessssesseeeeeesesens 65 Declaration of Commonly iasccsvessacsin cesentessaeeciets daensudhasdslgscesensnadectdisietaensduaaeetisieeseneseectesneds 66 Appendix EE EE ER tatasiuts 68 4 INSTRUCTION MANUAL 1 General description This manual describes scales produces by AXIS Sp z 0 0 and their basic functions Standard execution scales are equipped with ME 01 A LED meter and stainless steel scales with ME 01 N LED In case of using these meters or special meter for eg batchin
21. 4B8A6000F 4BA300FN 4BA600FN 4BA1500FN 4BA2000FN 4BA3000FN i4BA6000F marked with CE mark comply with the following 1 Directive 2004 108 EWG electromagnetic compatibility and harmonized norms EN 61000 4 3 A1 2008 A2 2011 EN 61000 6 3 2008 A1 2011 2 Directive 2006 95 WE low voltage and harmonized norm EN 61010 1 2004 Moreover scales with the following markings on the name plate C Exx M the number of the Notified Body responsible for EC verification 1443 two digit number of the year of EC verification a green metrology sticker with M mark a protective seal affixed by the Notified Body comply with the requirements on the Type Approval Certificate WE No T7950R0 and are verified to comply with EN 45501 1999 INSTRUCTION MANUAL 67 Additional information Conformity evaluation for the Directive 2006 95 WE and 2004 108 WE was carried out by Research Laboratory of Electrotechnology Institute Division Gdansk accredited by PCA Conformity T7950R0 evaluation was carried out by NMI Certin B V Notified Body No 0122 Per pro Director of AXIS Sp z 0 0 Production Manager Jan Konczak Date 25 04 2012 68 INSTRUCTION MANUAL Appendix A Information s concerning double range scale options 1 General description Double range scale s have capability of work with greatest accuracy in bottom measuring range part Weighing of smallest mass is mo
22. 68 Pallet scales 4BA PA oraz 4BA PAN PA N PA N PA N PA N PAN PA N lt As Pe ee O width x lenght x height width x lenght x height 4BA PAN stainless steel IP65 4BA PAN stainless steel IP68 INSTRUCTION MANUAL 9 Skid scales 4BA PZ and 4BA PZN Scale type 4BA300 4BA600 4BA1000 4BA1500 ee PZ N PZN P N PZN PZ N PZN Operational temperature 10 40 C Weighing time Skid dim width x lenght x Pk height 5m Indicator protection rating 4BA PA no IP 4BA PAN stainless steel IP65 Sensors protection rating 4BA PA IP67 4BA PAN stainless steel IP68 Foundation scales 4BA F and 4BA FN in Foundation depth 128mm Platform dimensions Balance weight Minimum load Min 10kg 20kg 20kg 300kg 600kg 1500kg 2000kg 3000kg Precision cass Weighing time lt 3s Operational temperature 10 40 C 230V 50Hz 8VA NIMH AA size 4 pes About 6 h with display backlighting and 16h without ME 01 A 18 no IP ME 01 N 18 IP65 Sensors protection rating IP68 1000x1000mm 1409 e e 1 Oo e oo a ee E ey ae ns EN 10 INSTRUCTION MANUAL 5 Meter ME 01 balance keys and indicators Version with LED display key key key key key key key indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator at NET Wl W2 HOLD FUNC PCS g kg lb uni
23. AL 33 15 3 Pieces counting PCS 0 00 Fr v gt 23 40 MENU v b PCS T gt PCS OFF KG PCS on T v gt PCS Sr PGS 5 Ee v WAIt WV i 5 v i 0 v This function enables to count identical pieces e g turnbuckles or buttons A measurement is performed in two phases first phase single piece weight calculation on the basis of defined pieces amount 5 10 20 50 100 200 or 500 pieces second phase pieces counting First phase options PCS recalling of a value inserted earlier this quantity must be inscribed earlier PCS SEt set any amount of pieces in a sample PCS uM set unitary mass directly PCS rS inserting number of details in a sample and receiving of their mass from other scale connected by RS 232C It is advised that single piece weight is not less than one reading unit and sample weight used in first phase is bigger than 100 reading units To leave function press MENU key and then using gt T lt key chose PCS and PCS oFF Note 1 PCS Err communicate signalises that a sample was not put on the pan or if single piece weight is less than one reading unit it is possible to count pieces but measuring error is bigger 4 In scales equipped with LCD display weigh
24. INSTRUCTION MANUAL 39 15 8 Label choosing function LAbEL This function is used in scale with ELTRON SErIAL function data protocol This protocol enables label printout with actual scale indication and chosen data from Print special function variable data for example date and time Other data for example company address product name barcode can appear on label as a constant text Label patterns with number 4 digit used by user should be saved in scale memory according to printer manual Label pattern choice is made by inscribing label number using LAbEL function Press MENU button When LADEL is displayed press T lt key 5 00 MENU Actual label number will show To enter new label number press T lt key p to exit function without number change press MENU LADEL T To inscribe label number use keys 30 digit increase Lets gt T next digit v MENU end 04 POS v hy 2 T After entering label number putting load and pressing 3 key will cause sending data to ia label printer 20 04 E0 hy Data format sent to label printer label nr 1 v language EPL 2 27 US 55 53 OD OA FR 0001 46522230 30303122 0D OA 3F OD 0A 5 00 El 00 00 30 30 3A 30 30 0D 0A 2000 00 00 32303030 2E30302E 3030 0D 0A
25. alance on flat horizontal foundation in place not subjected to mechanical vibrations and strong air movements 3 Air bubble in level should be located in the middle position Good Bad 4 Attach meter to the wall desktop or tripod option choosing one of three methods A N NS 5 Connect the supply cable plug to socket with protective contact when balance is unloaded 16 INSTRUCTION MANUAL 8 2 Preparing overrun scales 1 Unpack balance removing protective foils 2 Place balance on flat horizontal foundation in place not subjected to mechanical vibrations and strong air movements Take care if the scale stays on all four legs 3 Air bubble in level should be located in the middle position Good 4 Lift scale corners up and put locks under in such way that scale legs go into prepared holes 5 Mount locks permanently to the ground using 10 holes 6 Put balance approaches drives on settling them into locks 7 Unscrew transport handles mounted for transport 8 In hermetic scales plug not used joints with supplied caps Attach meter to the wall desktop or SN tripod option choosing one of three methods 9 Connect the supply cable plug to socket with protective contact when balance is unloaded INSTRUCTION MANUAL 17 Yoo BR wp 8 3 Preparing foundation scales 8 3 1 Preparing foundation CAUTION Decision of
26. digit gt decimal point FT next digit MENU end While inscribing ld Prod user can use scanner connected to RS232C interface If the scale is equipped with two serial joints after choosing Print function user can independently configure both interfaces Port 1 and Port 2 42 INSTRUCTION MANUAL Sample printout during normal weighing all printout positions deactivated 20 07 kg 20 04 kg 20 04 kg Sample printout during normal weighing with clock option all printout positions deactivated 20 07 kg 2012 11 08 10 01 20 04 kg 2012 11 08 10 01 20 04 kg 2012 11 08 10 01 Sample printout during normal weighing all printout positions activated BA30 MAX 30kg e d 0 01kg SIN ID OPER 000001 DATE 2012 11 08 12 26 3 01 OPCS 0 000 g 3 08 kg 0 00 kg 3 08 kg 0 00 kg INSTRUCTION MANUAL 43 15 11 Function for weighing large animals LOC The function allows weighing animal moving on the scale 0 00 MENU VW LOC h gt Te v LOC oFF Nr LOC on h gt Te 0 00 Important notes 1 The loads less than Min are not averaged h Press MENU key When LOC function is displayed press gt T lt key The following options appear on display successively LOC oFF leave the function LOC on a
27. e proper meter user manuals INSTRUCTION MANUAL 7 3 Completation Basic set includes 1 The scale 2 RS232C connector only 4BA N 4BA FN 4BA PAN 4BA PZN scales 3 CD with user manuals 4 Warranty 4 Technical data Platform scales 4BA and 4BA N Scale type Maximum load Max Reading graduation d Verification graduation e Minimum load Min Tare set range Precision class pS Se Operational temperature 10 40 C Weighing time Platform dimensions Balance weight 1000x1000x80 85 mm 60kg 1500x1500x80 85 mm 140kg 1500x1500x112 110 mm 150kg En 1250x1250x80 85 mm 100kg 500x2000x112 110 Display cable length Power supply 230V 50Hz 8VA nternal supply option NIMH size AA 4 pcs Accumulator working time About 6 h with display backlighting and 16h without Indicator protection rating 4B lack of IP 4BIN stainless scales IP65 Sensors protection rating 4B IP67 4BIN stainless scales IP68 mm 190kg 8 INSTRUCTION MANUAL Overrun scales 4BA NA and 4BA NAN N N N N N Precision class bl 10 40 C lt 45 Platform dimension max exter 860x1000mm 1000x1250 1250x1500mm tread x lenght mm 1100 x 355 x 50mm 1250x415x50 1500 x 470 x 60mm szer x dt x wysoko mm 230V 50Hz 8VA NIMH size AA 4 pcs About 6 h with display backlighting and 16h without 4BAINA no IP 4BA NAN stainless scales IP65 4BAINA IP67 4BA NAN stainless scales IP
28. er to allow this after weighing of each ingredient tare the scale After weighing of several ingredients reading total weight is possible despite scale taring In order to do that press MENU key select rECIPE function once more and use rEC oFF option Sign signals total weight indication Recipe is finished when gt T lt key is pressed When sign is displayed recipe continuing is possible rEC Con option is used for that Note Sign on the left side of display informs about rECIPE function activity INSTRUCTION MANUAL 37 15 7 Function for calibration with external weight CALIb Calibration with external weight should be performed if scale accuracy is not satisfactory Calibration weight stated in technical data table for the scale or of better accuracy should be used then Operations sequence 0 00 Press MENU key to display user functions MENU shown one by one in loop bd by Press gt T lt key when CALIb function appears CALIb gt T l The following options will be displayed vw hy CAL on calibration with external recommended value weight see technical data CAL on CAL StP calibration with external weight confirmation of next steps MENU key out leave without changes CAL StP T lt Press gt T lt key when CAL StP option appears vw hy calibration in two steps mM gt Te Press MENU and
29. errrrrrrrsnsnrsrnenenrnnr 31 15 2 Autotare function AutotAr Ladseskassrreg0daeerkasaGtesme 32 15 3 Pieces counting PES A ae 33 15 4 Function for changing mass unit Unlt rorirererererrrrrrvrvrvrrrrrsrrrrrrvrrerererrrrrrrnrsrserenrsnn 34 15 5 Percentage weighing function PErC ssssssssssssssssssssssssssssssesssssessssvereeeseresses 35 15 6 Recipe weighing function RECIPE ccssssscsssssssssssessssssssssssesssssessssvaseceersrses 36 15 7 Function for calibration with external weight CALIb cccccsssessesssseseeeeeeeees 37 15 8 Label choosing function LA EL uuassnenspssnasermnad ee aese 39 15 9 Serial port parameters setting SErAL menrvrvrrrrrrrvrvrrrrrsrsrrrrvrrerrrrrrrrsrssrsrsenennsnn 40 INSTRUCTION MANUAL 3 15 10 Printout configuration Pin aas4asvv4v4v4v4v45v4vv4v4dassesaer 41 15 11 Function for weighing large animals LOC rrvrrrrrnrrrnrvrrrnrsrsrrvrvrverererrnrsrsrrnrnenenenr 43 15 12 Constant GE FE soian a n 44 15 13 Function for maximum value indication UP orvrvrrrrrrnvrrrnrsrsrsvrvrrerrrerrrrsrrrrnrsenennr 46 15 14 Force measuring function MEWO cssssssessssssseecessssssssssssseseeseesssssssserenseserens 47 15 15 Anti disturbance filter function FILtEr eerrrrrrrrvrvrverrsrrrrrrrrverererrrrsrrnrnrserenennsnnn 48 15 16 Total weight function Ab Lava vore ean 49 15 17 Checkweighing function thr areca nesta cade Grater at acu aeae meme aaa 5
30. ervice centre Err O MENU v ZErO gt Te Vv k04 E0 v bb 1 oe 12 0 0 v bb 1234 MENU v 35007 0 v 0 00 Press MENU key When ZErO is displayed press OT lt key On the display a sign ZEr Cod will show up momentary and the a dash on last digit position To enter code in new scale 1234 use keys 0 lt increasing digit PT next digit Menu end of inscribing The following options appear successively on display ZEr Cod enter new secure code value ZEr SEt enter new zero value Using T lt key choose ZEr Set Direct result from A C converter will appear on scale display When the pan is empty press gt 0 lt key Wait for finishing zeroing process In order to change access code use ZEr Cod option as mentioned earlier INSTRUCTION MANUAL 57 15 21 Setting backlight function b_LIGHt 0 009 MENU v b b LIGHT sy v O L On st v The function is used for choosing the work mode of scale display backlight b_L OFF switch backlight off b_L on switch backlight permanently on b_L ECO switch off after 30 seconds of inactivity no load changes and no key operation b_L bAt like above but when powering f
31. et mode use thr CFG option Default option is Indication To leave the function press MENU key and then choose thr and thr oFF options 54 INSTRUCTION MANUAL 15 18 Function for setting date and time dAtE 0 00 MENU v b CATE gt Te b dAt oFF NG dAt on gt Te v b hgg MM gt T v NA b h13 18 ape h X h13 19 are TIN v b h13 19 ZIN d mm dd gt Te r rrrr gt Te 2009 gt Te z b 0 00 The function allows setting current date and time of scale internal clock and mode of its use The function has the following options dAt oFF deactivate date and time during printout of current weighing result dAt on activate date and time during printout of current indication l gt key dAt SEt change current date and time dAt Pin data and time secure password to prevent from changing date and time by unauthorized personel dAt For data printout in USA or EU format The example at the left presents how to set current date and time using dAt SEt option On successive positions digits are changing automatically or manually using gt 0 lt key several times In order to choose appropriate digit and move to the next position use OT key After setting proper date and time it should be activa
32. eys gt 0 lt WZ hy L gt Te and MENU out printout a setting value of tare tAr SET T v h Press T lt key during tAr Set displaying By pressing gt T lt key choose proper memory tArE Ol pr cell where tare will be stored tAr 01 02 10 v h Choose inscribing method MANUAL inscribing using keys gt 0 LF MANUAL r gt T lt and MENU hy Pan inscribing mass value that is on the pan v z 204 204 After storing tare the scale starts working with inscribed tare value vy bb 3 sje hy Note NG Tare value is stored in memory also after unplugging the scale from the mains 30 04 E0 37 MENU INSTRUCTION MANUAL 45 Weighing with constant tare Og MENU v tArE eye 7 tAr on PT v TArE OT PT v 39 v Og v 50g In order to use tare value that is located in memory choose from menu fArE function and then tAr on option A list of memory cells will show up tAr 01 02 10 Cells with inscribed value are marked with sign ATTENTION In scales with LCD display cells with inscribed value are marked with o sign on the left side Active value is
33. f samples in toleranc TOL amount of measurements under allowable lower value TOL amount of measurements above allowable upper value TOTAL sum of weights of all n samples AVERAGE average weight as Total n MIN minimum weight in n samples MAX maximum weight in n samples ST DEV standard deviation ST DEV standard deviation percentage To finish work with this function and zeroing result register press MENU key and then when StAt and Sta oFF is displayed press T lt button NOMINAL TOLERANCE MAX N 50 000 g 100 500 SAMPLE TOL NOM TOL 10 007 g 20 125 g 20 126 g 30 205 g 30 284 g 30 201 g 40 557 g IN TOL lt TOL gt TOL TOTAL AVERAGE MAX MIN MAX MIN ST DEV ST DEV 25 25 0 0 1264 664 g 50 587 g 91 131 g 10 007 g 81 124 g 20 6480 g 40 82 Statistics function cooperation with computer and Printer Scale can be equipped with two serial ports marked as RS232C I computer and RS232C II printer After each data printout by printer identical set of data is sent to computer After sending by computer initialization signal S A CR LF 53h 49h ODh OAh the scale sends to computer Statistic data enclosed in histogram INSTRUCTION MANUAL 63 15 25 Paperweight calculation PAP This function enables to calculate paperweight of 1m of paper basing on samples of known area For quick access the function is accessible direct
34. g meter it is essential to use proper user manual for individual meter type All balances are tested in respect of metrology According to order balances may be verified or calibrated EC verification conformity assessment of balances is required for special applications trade tariffs pharmacy recipes medical and pharmaceutical analysis packing of goods For other applications it is recommended to replace verification with calibration Verified balances have the following verification features protection stamps located on balance meter and converters connection box installed under the bearing surface Office of Measures marks and green metrological mark located on the rating plate Balances classification PKWiU code 29 24 23 Certificates Mi 150 l CG Certificate ISO Certificate of type approval PN EN ISO 9001 2009 no T7950 no AC 090 1141 2245 2011 AXIS management system INSTRUCTION MANUAL 2 Meters Depending on scale s application it can be equipped with following meter 000 Donen g ME 01 A LED Standard universal ME 01 meter in aluminium A housing and LED display 18mm digits height Full set of special functions chapter 15 and standard set of keys ME 01 A LCD Standard universal ME 01 meter in aluminium A housing and LCD display 18mm digits height Full set of special functions chapter 15 and standard set of keys ME 01 N LED Standard universal ME 01 meter
35. h Ready for operation N7 0 ma 200 22 INSTRUCTION MANUAL 10 Operation principles 1 Before each measurement the balance should be properly zeroed which is signalled by 30 indicator If the zero indication is not shown when the balance is unloaded or is displayed press the 0 key The balance enables tare setting in the whole measuring range It is performed by pressing gt T lt key Weighed mass should be placed in the platform centre Do not drop weighed objects on the platform 1 Do not overload the balance over 20 of maximum load The weighing result should be read during the indicator lighting which indicates the result stabilization When there is no weighing but the balance should be ready for operation it may be switched off by O key It causes the balance reading system deactivation end entering the standby mode Balance turning on is performed by pressing 1 key Protect the balance from dust aggressive dusts and liquids For cleaning purposes use water and dry it INSTRUCTION MANUAL 23 11 Balance test During balance operation in order to confirm its efficiency it is recommended to check the weighing precision by putting and object of exactly known weight before and after series of measurements For testing of verified balances use weight standard having valid standardization certificates In case of allowable measurement error exceeding contact
36. hour rrrr mm dd 10 signs year month day masa 10 signs scale indication mass unit P1 Steering instruction Attention 1 Except variable signs constant signs also can be inscribed for example factory name product name and so on 2 In standard one label pattern is possible to prinout number 0001 Using bigger amount of patterns other label numbers is possible thanks to LAbEL special function 3 To achieve label printout label printer must have inscribed label pattern label pattern is created on computer and using computer it is saved to label printer memory Label pattern is designed by ZEBRA DESIGNER program which is supplied together with label printer 4 Scales parameters and transmission protocol must corespond to label printer type 28 INSTRUCTION MANUAL 14 Basic function To make clear how to manage with each function in further part of instruction descriptions are replaced with pictures Ian A 2 30 T h v s7 14 1 Normal weighing gt 0 KBs 2 30 puta load on the pan remove the load from the pan press the key when indication is displayed forced change automatic change Press gt 0 lt key T lt key in non legalized scales which zeros the scale operates only when the pan is empty Weighing result should be read when the indicator lights INSTRUCTION MANUAL 29 14 2 Weighing with tare
37. in stainless steel housing and LED display 18mm digits height Full set of special functions chapter 15 and standard set of keys ME 01 N LCD Standard universal ME 01 meter in stainless steel housing and LCD display 18mm digits height Full set of special functions chapter 15 and standard set of keys ME 01 N 25 Universal meter with LED display 25mm digits height in stainless steel housing Full set of special functions chapter 15 and standard set of keys 6 INSTRUCTION MANUAL ME 11 N LCD surcharge meter with numerical keyboard designed to operate special functions that need inscribing data e g product code unitary mass stainless steel housing ME 02 N LCD surcharge designed for one ingredient or multi ingredient batching numerical keys stainless steel housing SE 03 N LCD surcharge designed to cooperate with label printer numerical keys stainless steel housing SE 12 N 2xLCD surcharge designed to operate with computer through RS485 or LAN network with possibility to connect scanner and label printer options 2 displays digit weight indication and text menu and data stainless steel housing SE 22 N 2xLCD meter surcharge one ingredient or multi ingredient batching 2 displays digit mass indication and text recipe ingredients names etc stainless steel housing ATTENTION In order to get acquainted with special functions and other functionality us
38. ing unit is visible and C sign is replaced with pcs 34 INSTRUCTION MANUAL 15 4 Function for changing mass unit Unlt 1 609 MENU v b Unit sTe v amp b CArAt ST z 8 00 The function allows selecting weighing unit CarAt 1 ct 0 2 g carat MGrAM 1mg 0 0019 milligram KGrAM 1kg 1000g kilogram Pound 1 Ib 453 5923749 English pound OunCE 107 28 3495239 ounce OunCEt 10zt 31 1034763g pharmaceutical ounce GrAln 19r 0 064798919 grain PennYW 1dwt 1 555173849 jewellery mass unit GrAM 1g gram The way of choosing carats as weighing unit is shown on the example Attention In scale with LCD sign is replaced by designations of mass units lb kg oz ozt ct INSTRUCTION MANUAL 35 15 5 Percentage weighing function PErC This function allows displaying weighing result in 100 0 00 percents I f A measurement is performed in two phases v first phase weighing a reference sample 100 19 00 MENU hy second phase measuring specific sample v as a percentage of the reference sample PErC gt T Weighing result is displayed in different format depending on the weight value of reference WwW hs sample For weight values of reference sample 0 3 5 of weighing range result is displayed in format 100 for range 3 5 35 in format 10
39. ith loaded pan remove a load from the pan SErvic e mechanical damage of the load cell contact an authorised service put the pan on L pan missing contact an authorised service mechanical damage H remove the load from the pan overloading contact an authorised service mechanical damage place the scale on a stable ground not affected by indicator does not unstable ground appear vibrations mechanical vibrations and air flows airflows scale is damaged contact an authorised service as above taring in progress taring could not be finished the load is too small zero the scale or press B G key or B G key was used again the load is too big to be zeroed tare the scale QT 66 INSTRUCTION MANUAL Declaration of Conformity AXIS Sp tka z 0 0 80 125 Gdansk ul Kartuska 375B confirm with all responsibility that scales 4BA300 4BA600 4BA1500 4BA2000 4BA3000 i 4BA6000 4BA300N 4BA600N 4BA1500N 4BA2000N 4BA3000N and 4BA6000N 4BA300NA 4BA600NA 4BA1000NA 4BA1500NA i 4BA2000NA 4BA300NAN 4BA600NAN 4BA1000NAN 4BA1500NAN and 4BA2000NAN 4BA300PA 4BA600PA 4BA1000PA 4BA1500PA 4BA2000PA 4BA3000PA 4BA300PAN 4BA600PAN 4BA1000PAN 4BA1500PAN 4BA2000PAN and 4BA3000PAN 4BA300PZ 4BA600PZ 4BA1000PZ 4BA1500PZ 4BA2000PZ 4BA3000PZ 4BA300PZN 4BA600PZN 4BA1000PZN 4BA1500PZN 4BA2000PZN and 4BA3000PZN 4BA300F 4BA600F 4BA1500F 4BA2000F 4BA3000F i
40. ly by pressing MENU key S 009 SF v b 8 1 9 MENU v PAPEr gt Te v b PAP n gt Te v b O pcs gt Te v amp b _ 09 v b Te v b 10 MENU h PAP ArE gt T v 0 00000 gt T b 0 01 MENU v PAP on gt T v 81 0 The balance must be tared just before the measurement Place the specific sample quantity of the same area possible values 1 2 5 10 20 50 100 Press MENU key to access Function Menu To enter the function press gt T key when PAPEr is displayed Press OT lt key when PAP n is displayed Enter number of samples using 30 increasing digit PT next digit MENU end of inscribing Press T lt key when PAP Art is displayed Enter area of a single sample as above The result of paperweight measurement is finished with mark pointing g m unit In order to finish work with function press MENU and then using T key choose PAPEr and PAP oFF Note 1 PAP Err communicate marks that wrong values were inscribed in PAP n or PAP ArE 64 INSTRUCTION MANUAL 15 26 Main mass unit change function Ib bAL option 0 00
41. marked with v sign Choose proper memory cell using 7 lt key tArE function is activated with chosen tare value Moreover the scale will indicate nett weight weight on the pan minus tare values Using gt T lt key or 0 lt while empty pan causes scale zeroing and then substraction of recalled tare Minus indication will show up 46 INSTRUCTION MANUAL 15 13 Function for maximum value indication UP This function allows holding maximum or minimum value indication shown by the scale at the moment 0 00 MENU v gt UP gt Te v UP oFF Z HIGH DTe v 1 00 v 10 00 v Before measurement scale should be tared Function has following options UP oFF function off HIGH holding maximum value LOW holding minimum value Pressing T key will cause result zeroing Note Autozeroing function and the stabilisation indicator are deactivated when UP function is running Weighing result is continuously averaged from 5 measurements INSTRUCTION MANUAL 47 15 14 Force measuring function nEWto 0 00 MENU v b NEWto PT v b nW oF VvV nNWon IPT v gt 0 000 Function activation causes displaying result in force units N Press MENU key Using gt T lt key choose NEW
42. on StA o activate function work with printout of chosen weighting results StA activate function work without printout StA n maximal samples value Sta nM inscribing nominal value for statistics Sta fOL inscribing tolerance in Sta tAr automatic tare on off y Ea GH 0 00 StA CFG function configuration Auto Automatic work samples are confirmed v after loading the scale and indication stabilization lt a ManuAL manual work confirmation is made by 1 00 pressing L key out exit from function WV Remember first to inscribe nominal weight value 0 00 and tolerance mentioned above After that push gt T lt key when StA o is v displayed h 2 00 Put on successively objects on the pan remove after indication stabilization in order to add them to v measurements register 0 00 Q MENU in order to obtain printed statistical results from measurements series press MENU key and OT key when StAt is displayed and later StA Prn After printout two options are enabled rESET erasing results Contin continuation StAt v v GH Get Contin gt Te dd 0 00 9 62 INSTRUCTION MANUAL Pressing Ls key printouts estimated values and histogram Nominal nominal value Tolerance accepted value in percentage N number of sample IN TOL number o
43. re precise This type of scale s have two measurement range Max 50 of maximum load mostly Max gt 100 of maximum load and adequate reads digit di i d dj lt do Double range options causes change of scale s operation after turn on in small mass range 0 Max scale displays result with reading unit di when the load pass the Max scale changes reading unit on dz from this moment scale displays result with reading unit d2 on all measure range 0 Max return to unit d4 is succeed after zeroing the scale 0 key or when all mass is removed from pan indicator 0 lt dz dy Max Max 2 Double range scale parameters Range and graduation values are represented on nominal table on the scale
44. rom accumulators only out out without changes Switching backlight off causes decrease of energy consumption by the scale what is important during powering from accumulators 58 INSTRUCTION MANUAL 15 22 Charging accumulators function bAttErY option 0 009 MENU v b bAttery gt Te vb bAt OFF 7 bAt on gt Te v b 0 00g bAttErY function allows switching on or off charging accumulators during work with feeder and checking their power level The function has the following options bAt OFF charging off option required if ordinary batteries are used bAt on charging on accumulators are being charged even after switching scale off using 1 key bAt VoL reading power level of accumulators in go back to mass indication pressing MENU key out leave without changes An attempt of charging ordinary batteries can cause serious damage of the scale INSTRUCTION MANUAL 59 15 23 Automatic switching off the scale function AutoOF The function is helpful in scales supplied from accumulator The function causes scale to switch off automatically 0 009 MENU Press MENU key vw hy When AutoOFF is displayed press T lt key The following options appear successively on v hy AOF oFF deactivate function AOF on activate f
45. shold value option Computer Scale S L D1 DN CR LF 53h 4Ch D1 DN ODh OAh D1 DN threshold value maximum 8 characters negative value digits dot decimal separator number of digits after dot should be the same as on scale display Scale Computer without response Example in order to set low threshold 10009 in scale B1 5 d 0 5g the following order should be sent SL1000 0CR LF 53h 4Ch 31h 30h 30h 30h 2Eh 30h ODh OAh in order to set low threshold 100kg in scale B150 d 509 the following order should be sent L100 00 CRLF 53h 4Ch 31h 30h 30h 2Eh 30h 30h ODh OAh m Setting high threshold value option Computer Scale S H D1 DN CR LF 53h 48h D1 DN ODh OAh D1 DN threshold value see Scale Computer without response Connecting cable WK 1 scale computer 9 pin interface SCALE COMPUTER N lo 26 34 fo 54 o 70 89 Connection cable WD 1 connects scale with AXIS printer SCALE KAFKA PRINTER lo 20 34 fo 54 o 70 89 Setting of internal switches of AXIS printer INSTRUCTION MANUAL 27 ELtron protocol Transmission parameters 8 bits 1 stop bit no parity baud rate 9600bps After using Eg key in scale ScaleLabel printer set of instruction in EPL 2 language that initialize label printing US Steering instruction FR 0001 Label number define instruction Instruction that starts list of variable signs mm gg 5 signs minutes
46. t MIN OK MAX W1 zero stabilization net weight metrological weighing indicator indicator indicator data result Falala LILI Li 0090 O O O W2 HOLD TOTAL FUNC PCS scale keys switch on switch off standby tare subtract package weight from weighed mass zeroing when the platform is empty result printout special function menu switch special function weighing high resolution zero indicator result stabilization indicator net weight indicator after using gt T lt key first range of two range scale is on second range of two range scale is on indication hold function LOC and UP special function on pieces counting mass unit indication weighing result under threshold I weighing result between threshold and Il weighing result above threshold II INSTRUCTION MANUAL 11 Version with LCD display zero stabilization nett mass weighing metrological indicator indicator indicator result data bar indicator OFF BAT CAL MIN OK MAX 9 mm NET etngim A ka 50 j O scale keys key O switch on switch off standby key 3T tare subtract package weight from weighed mass key gt 0 lt zeroing when the platform is empty key E result printout key MENU Special function menu key B G gross mass indication key HR high resolution indicator 30 zero indicator indicator er result stabilization indicator indicator NET net weight
47. ted with dAt on option UE rrrr mm dd gg mm USA mm dd rrrr gg mm AM PM gg hours mm minutes AM before noon PM after noon mm month dd day rrrr year Attention Inscribing non zero PIN value causes showing PIN sign during next date and time changing and inscribing 4 digit code is necessarily using key gt 0 lt INSTRUCTION MANUAL 55 15 19 Radio communication channel choice function rF CHn Function enables choosing radio communication channel beetwen the scale and a pilot In scale and in pilot the same radio channels must be chosen Function should be used when communication is disturbed by other devices that use the same communication channel 0 00 MENU v 6 rF CHn gt T v b CHn 01 KVA CHn 02 CHn 16 Te gt 0 00 Press MENU key and choose rF CHn by pressing gt T key The following communicates will appear on display Na wy wietlaczu pojawi si kolejno CHn 01 channel 1 CHn 02 channel 2 CHn 16 channel 16 out out without changing channel In default setting channel 01 is on 56 INSTRUCTION MANUAL 15 20 Entering reference zero function ZErO Note This function is enabled in non legalized scales only ZEr0 function allows entering new value of reference zero value referred to empty pan without need of contacting with authorised s
48. to function and then NW on Attention Units converting from mass kg to force N is made for acceleration of gravity 9 9 80665m s2 Note 1N 0 1019kg 48 INSTRUCTION MANUAL 15 15 Anti disturbance filter function FILtEr 0 00 MENU v amp b FILTEr gt Te gt FIL OFF 7 FIL 10 Sr FIL 20 FIL 40 DTe vb 0 00 This function allows using digital filter with selected intensivity during weighing Filter reduces the influence of mechanical vibrations air blasts base vibrations on measurement result Press MENU key and select FILtEr by pressing PT e key The following options will be shown successively on display FIL oFF work without filter FIL 10 filter weak FIL 20 filter II medium FIL 30 filter Ill sharp FIL 40 filter IV very sharp Select on of four filters This will cause starting weighing with selected filter In order to return to normal scale work use MENU key and choose FIL oFF INSTRUCTION MANUAL 49 15 16 Total weight function totAL The function allows calculating total weight for series of measurements which can be greater than scale capacity It allows calculating total weight as well as average value When totAL is displayed press gt T lt key TotAL gt T The following options will appear successively 7 hs
49. trol optical indicator Indication mode batching devices Batching mode Standard scale is set for cooperation with optical indicator On outputs P1 P3 Relays socket short circuit states appear as result of comparison scale indication with threshold values On the chart below output states are shown during increasing load on the scale for both working modes Indication mode Batching mode A zero thr I treshold P2 thr the I the I P3 P3 thr Il zero treshold In Batching mode on P1 thr I and P2 thr II outputs short circuit impulses appears for time of 0 5s On P3 zero output short circuit state appears when indication does not exceed threshold value signalling zero load 52 INSTRUCTION MANUAL Relays connection diagram shield Relays output is the open collector transoptor output with load capacity 25mA 24V Transmitter inputs must be protected with diodes e g 1N4148 It is advised to use MS3K P electronic board sold separately consisting of RM96P transmitters with DC24V input voltage and AC250V 3A output Important notes 1 After switching the scale on both thresholds are set to maximum values 2 When setting upper threshold value pay attention that its value is not below lower threshold value 3 Setting lower and upper threshold value is possible after sending appropriate orders from computer what is described in scale user manual INSTRUCTION MANUAL 53
50. unction scale turns off after 5 minutes of not making any actions AOF on gt T AOF bAt as above but only when supplied from accumulators v by Out out without changes 0 00g P 5min OFF 60 INSTRUCTION MANUAL 15 24 Statistical calculations function StAt Attention Function available on demand It replaces other special functions This function evaluates from series of measurements max 1000 statistical parameters of weighting process Adding successively measurements to register is automatic and it occur after the scale is loaded and its indications stabilize After each loading printout is made with number of measurements result date and time if clock is installed and the function is activated For the obtained measurements series the scale evaluates n number of samples sum X sum of all samples sum x gt Y x x average value sum x n min minimal value from n samples max maximal value from n samples max min maximal value minus minima value 1 VED 2 S standard deviation S DV a x S srel variance factor srel X Statistical calculations results can be printed INSTRUCTION MANUAL 61 Order of operations Press MENU key When StAt is displayed press gt T lt key MENU The following options are displayed O lan oO StA Prn monitoring and printout of statistical data StA oFF deactivate functi
51. utomatic weighing after loading the scale LOC Prn the measurement initiated manually by pressing E key When LOC on is displayed press gt T lt key Tare the scale using T lt key if necessary and place the animal on the pan Wait until the weighing result is averaged scale display will be blinking Then scale will show stable averaged result and will send it through serial port Final result is displayed on the display and send via serial port to computer or printer The result remains on display for about 30 second 2 In the case when placing the animal takes more than 5s it is advised to use LOC Prn measurement initiated manually It will allow performing measurement in right moment pressing gt key 44 INSTRUCTION MANUAL 15 12 Constant tare tArE This function enables to measure gross weight of a sample placed in a container of a known weigh value stored in the memory and to display calculated net weight of the sample Tare value is recalled from the memory with gt 0 lt or gt T key when the pan is empty Tare value may be entered using the keypad or by sampling container weight from the pan Operation sequence The following options are possible 3 g MENU tAr OFF leave the function vw hy tAr on activate the function with the previous tare value tArE T tAr sample tare value from the pan tAr SEt enter tare value with k
52. yte 15 CR Byte 16 LF Attention Network number different than zero Port nr function changes scale working mode communication with a computer is possible after logging the scale in with 02h scale number command To log the scale out use 03h command For example Using a program to test RS232 interface program is available in www axis pl programy komputerowe for scale number 1 please write 0201 to log in then SI and write 03 to close communication Asking about scale presence in system testing scale connection with computer Computer Scale S J CR LF 53h 4Ah ODh OAh Scale gt Computer M J CR LF 4Dh 4Ah ODh OAh Displaying a inscription on scale s display text communicate from computer Computer Scale SNnnXXXXXXCRLF nn displaying time in seconds XXXXXX 6 signs to display Scale gt Computer M N CR LF 4Dh 4Eh 0Dh OAh Scale tarring calling gt T lt key press Computer Scale S T CR LF 53h 54h ODh OAh Scale gt Computer without response Scale zeroing calling 0 lt key press Computer Scale S Z CR LF 53h 5Ah ODh OAh Scale Computer without response Scale turning on off calling I key press Computer Scale S S CR LF 53h 53h ODh OAh Scale Computer without response 26 INSTRUCTION MANUAL Entering to special function menu calling MENU key press Computer Scale S F CR LF 53h 46h 0Dh OAh Scale Computer without response Setting low thre