1. This unit intended for installation in a controlled environment temperature controlled indoor area free of conductive contaminants Avoid installing the UPS in locations where there is standing or running water or excessive humidity Do not plug the UPS input into its own output Do not attach a power strip or surge suppressor to the UPS Do not attach non computer related items such as medical equipment life support equipment microwave ovens or vacuum cleaners to UPS PLACEMENT amp STORAGE Install the UPS in a protected area that is free of excessive dust and has adequate air flow Place the UPS away from other units at least 20 cm to avoid interference For best performance keep the indoor temperature between 0 C and 40 C Storage All connected equipment should be turned off then disconnect from the UPS to avoid battery drain Unplug the UPS from the wall outlet Then turn off the UPS for storage Store the UPS unit covered and upright in environments where the ambient temperature is 20 C to 50 C with its battery fully charged SPECIFICATIONS MODEL 400 600 800 CAPACITY 400VA 240W 600VA 360W 800VA 480W Input Voltage 110 120 VAC Input Voltage Range 85 145 VAC Output Voltage 10 Bat mode Regulation Transfer Time Typical 2 6 ms Waveform Simulated Sine Wave Battery Type 12V 4 5Ah 12V 7An 12V 9Ah Battery Number 1 1 1 Charging Time 6 hours recover to 90 capacity
2. Dimension DxWxH 279 x 101 x 142 Net Weight kgs 3 55 4 25 4 9 Humidity 0 90 RH 0 40 C non condensing Noise Level Less than 40dB Specifications are subject to change without notice Do not dispose of batteries in a fire as they may explode Abaitery can present a risk of electrical shock and high short circuit current The following precautions should be observed when working on batteries 1 Remove watches rings or other metal objects from the hands 2 Use tools with insulated handles 3 Wear rubber gloves and boots 4 Do not lay tools or metal parts on top of batteries 5 Disconnect charging source prior to connecting or dis connecting batteries terminal Internal battery voltage is 12VDC Sealed lead acid 6 cell battery Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries When replacing batteries replace with the same number and type of sealed lead acid battery Do not open or mutilate the battery or batteries Release electrolyte is harmful to the skin and eyes lIt may be toxic Attention hazardous through electric shock Also with dis connection of this unit from the mains hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole at the connectors of
3. Line Interactive UPS 400 600 800 VA 1 Inspection The following items are inside the box UPS unit Remove the UPS from its package and inspect it for damage that may have occurred during shipping If any damage is discovered re pack the unit and return it to the place of purchase User Manual connect to Utility Power Connect AC power cord to utility power Then the UPS will start to charge inside battery For best result charge the battery for 6 hours prior to initial use OPERATION amp FUNCTIONS Turn On the UPS To turn on the UPS unit press the power switch lightly Then the LED will light up Turn Off the UPS To turn off the UPS unit press the power switch again Then the LED will go off cold Start Function When the UPS is off and there is no power utility it s still possible to cold start the UPS unit to power the loads Free Software Download Option Go to the website http www power software download com and download the ViewPower software Follow on screen instruction to install the software When your computer restarts the monitoring software will appear as an orange plug icon located in the system tray near the clock Front Panel Power switch Status LED Green LED solid on Utility power is normal The UPS is on AC mode Green LED flashing Utility power fails and the UPS is supplying power from battery plug in Equipment Plug your equipment t
4. e UPS will beep every second Overload When the UPS is overloaded the UPS will beep every 0 5 second to warn an overload condition Fault When there a UPS fault occurs the UPS will continuously beep Line Interactive UPS 400 600 800 VA SAVE THESE INSTRUCTION This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries This UPS utilizes voltage that may be hazardous Do not attempt to disassemble the unit The unit contains no user replaceable parts Only factory service personnel may perform repairs This pluggable type A equipment with battery already installed by the supplier is operator installable and may be operated by laymen The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3 5mA Connection to any other type of receptacle other than a two pole three wire grounded receptacle may result in shock hazard as well as violate local electrical codes Inthe event of an emergency press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS Do not allow any liquids or any foreign object to enter the UPS Do not place beverages or any other liquid containing vessels on or near the unit
5. o Battery Backup Outlets on the rear panel of the UPS NOTE Make sure that the UPS is powered on to protect all important devices from data loss during power failure Monitor Computer CAUTION NEVER connect a laser printer or scanner to the battery backup outlets of UPS The equipment may draw significantly power to overload the UPS REAR PANEL D log rea Es pe roto J z TA oH aUe Battery backup outlets Plug sensitive equipment into battery backup outlets Battery power is automatically provided in case of a power outage Ac input Fuse option The fuse will be burned out if an overload condition forces the UPS to disconnect itself from utility power Ouse com port option To monitor the UPS status such as unattended UPS shutdown and start up by using download software please connect the UPS and PC with USB cable included Owodem Phone line surge protection option Connect a single modem or phone line into surge protected IN outlet on the back panel of the UPS unit Connect from OUT outlet to the computer with another phone line cable ALARMS Battery mode When the UPS is in battery backup mode battery mode the green LED will flash and the UPS sounds an audible alarm every 10 seconds Low battery When the UPS is in battery backup mode battery mode and the battery energy begins to run low th
6. the battery when maintenance or service work inside the UPS is necessary To reduce the risk of overheating the UPS do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heater or furnaces Unplug the UPS prior to cleaning and do not use liquid or spray detergent TROUBLESHOOTING Possible Cause Solutions LED not lit eee Ee the power switch again to turn on the UPS low 6 hours Power cord loose Re plug the power cord Overload Remove some unnecessary loads Before reconnecting equipment please verify that the load matches the UPS capability specified in the specs Battery voltage is too Charge the battery at least low 6 hours Overload Remove some unnecessary loads Before reconnecting equipment please verify that the load matches the UPS capability specified in the specs Battery defect Replace the battery If any abnormal situations occur that are not listed above please call for service immediately
Download Pdf Manuals
Related Search
Manual manual manualslib manual car manuale digitale manually meaning manual timesheet manual transmission manual wheelchair manual arts high school manually update your device drivers windows manual definition manual for courts martial manual labor manual lawn mower manual muscle testing manually register devices with autopilot manual muscle testing grades manual transfer switch manualidades manual blood pressure cuff manual handling manual transmission cars for sale manual digital manual pdf manual autopilot enrollment
Related Contents
SP603 Manuel Francais V2 - ID-AL Instruções de operação SG9/SG98 - Mettler lynx a100 user guide Instruction Manual English - Simrad Professional Series "service manual" Philips Wireless speaker SBT550 Philips EcoClassic Standard lamp Halogen Bulb 872790025281125 User Manual - SharePoint Copyright © All rights reserved.