Gree AC Eudemon 2009
Contents
1. admin Old Password Mew Password Confirm Password Please Choose 4 Role F Administrator Add user fill in a name different from the existing user and then input the password Select a character and click Add to finish the operation Modify password Select user that needs to modify password in All users and then fill in the new password and click modify password Delete user Select the user to be deleted in All Users and click Delete 32 Role Management Users having the rights of User Management can add and delete role Click Menu gt System gt Role Management and the following interface will appear Role Management Authority Selection Permissive User configuration System configuration Devices configuration Timing control Charge Control am Examine amv Control terminals S o S S o a S o Role Marne Role Existed Administrator Add role select a power in the list of Authority Selection and fill in the name of role Next click Add Delete role Select the role to be deleted in the list of Exist role and then click Delete Notice The role being used can not be deleted 33
2. Gree AC Eudemon 2009 V2 35 4 5634 Copyright 2011 Gree Inc All Rights Reserved 1 2 WELCOM RE d i e e a mn RM ol OR ein 3 RO ee 3 end user license qaEEECIUPlIE E 3 s INTRODUC TON sais Lab ane detente s Funchon VE e des dates eh sde nn hr de ir its 5 E ooi E 6 amp EE E e E 8 20 IVP P D SE uiii EE 9 s JUI WEE 9 Rncineeribi NET E 10 JE Eu ET NEE 11 D a de se et ll ce ei io in 12 E PE DRE a E er it bein tn 13 gt Kompeni MANIP eer iiid reenn EEN 14 e Connec EE CN 15 JE 00 057 E 16 e CONTENT ee EE EE E E EEE E S EEEE A e E dO a A AE 17 meer LonlsuralmDi ege ee a aaa 18 s MYS C OMNA gege EE italia te 19 s Add Equipment EE 19 e BS WEE e Tt WEE 19 e Automatic Detection Configuration NENNEN enn 20 amp SullbmuDe Deletion ER RER en 21 e Units Installation Configuration ee ENEE EE EE EEN 22 XE er 23 Connection Management cccccccccccscccccccccscsscsccccccsssscccccess 23 L onnect EQUIDIDODUS rss tenons 23 Fatuent FEN auteure 24 AE WE CEG mer err 25 zu ic ez e 9 26 2 GTOUD CON OL EP de usseenctaawesssssecece sues 27 Group WEE AION E 27 e Zentre TTA 29 CDD don 30 WEE E EE 31 Wii 20r 3l lk RENE E 32 Ve UC cine gc ec de eee di co den niet 33 Welcome To Use Gree AC Eudemon 2009 Welcome to use Gree AC Eudemon 2009 Gree AC Eudemon 2009 is a remote control system newly introduced by Gree Elect
3. Shield Power Save vertical Auto Swing Cancel The list box in the top right corner shows all the groups to which one or more devices are assigned You can easily change your selection of group you would like to control Mark the check boxes to determine what parameters you want to control and change their values Finally click OK or click Cancel to do nothing Caution 1 Before control the group please make sure that the communication with devices is ok 2 The system will send group control commands after clicking OK It is normal that an overtime message appears in System Information USER MANAGEMENT Login The defaulted user upon startup is visitor who has not any right of operation but the right to read users interface and helps documents As a result it 1s necessary to login as a user with certain rights so that more operations are realized Click Main Menu gt System gt Login and the following interface will show 31 User Name Password Fill in user name and password and click Login to finish the operation You can login with user name admin and empty password for the first time User Management User It refers to those who use it A user can have several characters Role the integration of certain rights User management can add modify and delete user Click Main Menu gt System gt User Management and the following interface will show User Management All sers Wiser Name
4. Project a Project Identity DEFOOOOO000 Project Mame Country Province City Area Principal Telephone Mobile Phone E mail Note the project identity have to be unique Cancel 10 System Configuration Click Main Menu gt System gt System Configuration and the following interface will show System Configuration Protocal Choose protocols Pratacol Name Modbus Modbus Select all Cancel al Bis All COM numbers COM Number COM overtine 1500millisecond Overtime 1500 millisecond Set parameters as the following interface Overtime means after software sending a request command communication module should give a response in 1500ms 11 System Configuration Protocol Choose protocols Protocol Mame Modbus Select all Cancel all Bus All COM numbers COM Number COME 1 overtine 1500milisecond Overtime 1500 millisecond Now the system support Com and Modbus Bus Configuration Click Main Menu gt System gt Bus Configuration and the interface of bus configuration will show Bus Configuration All Identities Choose Identity bi Address COMl Add New Bus Indentity Bus il C COM P TCP IP sg d x Select the COM number in COM COMI is used in this example Then input Bus1 in Bus Identity the name is decided by yourself and click Add as the following figure Click Close to finish adding the bus Bus Configuratio
5. charge for the replacement modification update of software 2 Any replacement version or modification version or update version of this software offered by our company should be deemed as part of this software and be restricted by articles of this Agreement Unless this Agreement is replaced by another Agreement of replacedt version or modified version or updated version 3 If our company offers a replacement version or modification version or update version of this software you can use this software on condition that you accept any attached Agreement of the replaced version or modified version or updated version of this software also as for the replaced modified or updated software it s former using right will be automatically terminated once you start using the replaced modified or updated software and accept the Agreement of it E Reserve of rights Any other rights that are not authorized clearly belong to Gree Electric Appliances Inc of Zhuhai F Copyright of this software 1 The name of this software product and all the duplicates exist with the name of company on the disc or in this software 2 This software product includes but not limits to any image photo motion picture record music letter and affixed program of this software enclosed printed material and property right as well as copyright of any duplicate of this software are the possessions of Gree Electric Appliances Inc of Zhuhai 3 This software and document take
6. devices is ok Group Control Notice if it is your first time to run this system or devices were modified that 1s after automatic detection some devices have been updated you should operate group detection Menu gt Tools gt Group Operation gt Group Detection before group controlling Group Control After logining in there are 3 ways for you to enter the group control interface 1 Select a group in the GroupView first then turn to Menu gt Tools gt Group Operation and select Gree AC Eudemon 2009 System 5 View V Control C Tools T HelptH d w fe E Group Operation G ki ai Group Configuration M EXE EE D x Device Group Control C E eR Group iew mec 1 Group Detection D 2 Right click a group in the GroupView and select Group control Group n x De ga GroupView Ho Group Control Timing Control Network a Group Configuration 3 Select a group in the Group View first then click the icon LD in the toolbar Notice group control would be disabled if there are no devices in the selected group 30 Group Control EN Current Group meow 11 Control Parameters Power on off Mode F Setting Temp Fan Speed Power Save Cool Cooling Min Power SavefHeat d Heating Max Lack Shield Power Shield Mode Shield Temp
7. equipments are displayed in the interface according to the physical structure e Organized By Position the equipments are displayed in the interface according to the actual location e Organized By Groups the equipments are displayed according to groups 6 e Device Set Public Information decide whether the list of parameter to be displayed or not e System Information decide whether the figure will be displayed on the interface e Toolbar decide whether toolbar is displayed or not e Status Bar decide whether the state bar is displayed or not e Appearance Look different appearance of applied procedure can be selected Control Menu Each item of control menu is used for certain control of equipment Controlle Tools T Help H lE Connect C F Enable Timing Control E 1 i Disable Timing Control D t J Unit Control D Timing Control T i Automatic Detection A P kent Kg Jg e Connect enable the unit to communicate with the system e Disconnect stop communicating with the unit e Enable Timing Control to turn on the Timer function e Disable Timing Control the system will not deal with any timer order e Unit Control set the parameter of unit e Timing Control set timer order so that system will automatically order a control at certain moment e Automatic Detection to execute the function of automatic detecting Tools Menu In the tools menu it shows some extended functions of the system T
8. the changes to the group would take effect If you want to pull back click Cancel Notice it cannot recover the groups deleted by clicking Cancel Caution 1 Before configuring the groups please make sure that the communication with devices 1s ok If communication malfunction occurs during operation please delete the groups interrelated and retry later when the communication returns to normal 2 The system will send group configuration commands after clicking OK It is normal that an overtime message appears in System Information Group Detection Notice you should operate automatic detection Menu gt Control gt Automatic Detection first before group detection Before group controlling you should operate group detection Turn to Menu gt Tools gt Group Operation and select Group Detection ta Gree AC Eudemon 2009 t System View V Control C Tools T Help H T e E E D Al Group Operation G h 4 Group Configuration M Group D x Device Bc ge emm Co e Group Detection b 2 49 meow 1j ii e Gree AC Eudemon 20095 Click Yes and group detection begins All the information of groups will be written into corresponding modules 29 Automatic Detection Automatic detection is running and it takes several minutes Please wait For while Me Please wait a minute till the operation ends Caution 1 Before group detection please make sure that the communication with
9. the example users can use the basic function of equipment monitor and control If more detailed functions and helps are needed please refer to the following chapters 16 CONTENT System Interface Click Gree AC Eudemon 2009 exe in the installation catalogue to start the system only one procedure can be applied in each computer The procedure interface is as below Note The software would not run effectively when the computer is hibernating or stand by Gree AC Eudemon 2009 OX System S View V Control C Tools T Help H Menu Bar Het OD I 22 Er Toolbar n X Device COM 1 Module DDevice Device Set Public Information nx Timer state No COM 1 Module 1 Clear dust Off Cool heat pump Single cool Ultraviolet OFF System 1 thaw Indoor fan Low System 2 thaw Lock long distance control Lock OLD enviroome Swing left and right Off e Swing up and down OFF Sleep mode OFF Long distance shield save s Shield Device Set Public Information Dry Off Controller baot state Wait Forbid the assistant heat Forbid open Supper Off Long distance shield tempe Shield Long distance shield mode Shield Long distance shield on or off Shield Timer cancel No cancel Lock key state Unlock Clear dust clear No Prevent frost 1 run Off Fan valve close flag One or more valve open Fan valve online Flag No New wind Fan valve switch OFF Water pump OFF Card state Pull out W NetworkView a
10. works everyday and the start date 1s initialized as 2000 01 01 If some of COMs in Group aren t connected then the timing control command doesn t work by the way it will be reminded in Circulate region For example 10 87 2011 08 48 45 Becauze some of COMs in Group 10 aren t connected the timing control command doesn t work GROUP CONFIGURATION Group Configuration After logining in there are 3 ways for you to enter the group configure interface 1 Turn to Menu gt Tools gt Group Operation and select Group Configuration Gree AC Eudemon 2009 System S View V Contral C Tools T Help H LESS DE aaj GroupGperaton G Hal Group Configuration M Group 1 x Device emm Group Detection L 2 Right click in the GroupView and select Group Configuration Group n x Dev E ga Group iew CR Ge z A Group Control e CH p di Timing Control Position aal Group Configuration Network 27 3 Click the icon in the toolbar Group Configure Ho Group Mame Remark 1 meow Delete Devices MOT assigned to the group Devices assigned to the group Device Groups Assigned Device Groups Assigned COM Modulel1 Device 1 COM Modules Devicet 1 Add Groups To add a group input the group name and remark and click Add Then a group number will be assigned to the new created group Notice the group name could NOT be empty or more than 5 characters it could not consist
11. 2011 13 42 Link state Link state Link state Link state Link state Link state Link state Link state Link state Link state COM 7 JE Madule 1 Matural COMH 22 0 vertime LEM I 3 O vertime COM 34 0 vertime COM 1 25 O vertine COM 1 6 0 vertime COM 7 D vertime COMA 26 O vertime COM 1 29 Overtine COM 1 310 Overtine COM 1 gt Module 1 Natural means the software can detect Module 1 successfully via COMI COMI gt Module 2 Overtime means the software can t detect Module 2 via COMI After the automatic detection 1s finished system will display the result on Network Suppose the detected software version is higher than the current one the latter will still prevail for data processing Meanwhile the user will be notified of updating the software as well as of the communication module address for the current version software protocol and so on Gree AC Eudemon 2009 The software protocol is nat of the latest version maybe some parameters can t be displayed or controlled please upgrade it In order to upgrade it soon please send the following information to our Service personnel Device ID and prorocol high 0013 1 1 Device ID and protocol low 0013 41 01 Module address COM 3 Module 1 1 If the result conflicts with the equipment added by users manually e g User add GMV to the communication modular 1 of COMI but the resul
12. T u 1 E ir culate FT Operaton El x Device Set Public Informa ax COM 1 Module 1 Cool heat pump Single cool System 1 thaw No System 2 thaw No OUD environme 129 nx Ready Liser Name admin Timer Enable os 15 Control Unit Right click Equipment and select Unit Control in the menu as the following figure Network n x wW NetworkYiew E cow HD Maduleci Choose Delete Unit Control Timing Contral Rename After setting the parameter in control interface click OK to start operation as the figure below Control Onoff Oon Gert TEE Coolsave OoN Gi OFF EE HeatSave OON G OFF Fan once SwingMade OON OFF Silent Made SleepMode CON OFF Supper ON OFF EnvirSensorChoise Dryness CON OFF ContrallerBaotState CONVAIT 3 RESUMEBEFORE AssistantHeatFarbid COFORBIDOPEN ALLOWOPEN NewFanvalvestate LongDistanceContral LOCK Ce UNLOCK LongDistanceShieldSave SHIELD NOSHIELD LongDistanceShieldTemp SHIELD NOSHIELD CoobaveModesetTemp LongDistanceShieldMode SHIELD 3 NOSHIELD LangDistanceShieldOnOff SHIELD 5 NOSHIELD SeFTemp HeatSaveModeSetTemp Timer Cancel DNCEL NIOTCANCEI LackKeystate O Lock 9 UNLOCK IndoorFan CO HIGHT 6 Low CANCEL Check whether the modification 1s success or not by returning to the main interface So far the basic monitor configuration of duct is finished By finishing each step of
13. Timer state No COM 1 Module 1 G cow pud Ms a Cool heat pump Single cool a Module 1 Ultraviolet 9 System 1 thaw No 7 Indoor Fan FON System 2 thaw No Y Lock long distance control Lock Ee 12 C Swing left and right Off SINK ORIG c Swing up and down Off Sleep mode Off Long distance shield save s Shield Dry Off Controller boot state Wat Forbid the assistant heat Forbid open Supper Off Long distance shield tempe Shield Long distance shield mode Shield Long distance shield on or off Shield Timer cancel No cancel Lock key state Unlock Clear dust clear No Prevent frost 1 run Off Fan valve close flag One or more valve open Fan valve online flag No New wind Fan valve switch Off Water pump Off Card state Pull out Gate System Have Prevent Frost run OFF bd System Information nx d 05 16 2011 12 15 37 Connect COM 1 05 16 2011 12 15 37 Link state COM 1 gt Module 1 Natural The lamp beside the device have three state l green normal 2 red malfunction 3 yellow overtime unwonted response Notice It may happen that the system cannot auto exam normally because of the overtiming state of the equipments or Normal and Overtime appear in turn In this kind of situation please turn to the menu System The system install and enlarge the Overtime to 2000 3000 millisecond Then it can be fixed 24 Unit Control Users can control the unit with this system Click Menu gt Control gt Unit Contro
14. ame Duct The result is as below Network E NeEwnrkView zt come 2 Module Wut Connect Equipments I Connection Management Click Main Menu gt System gt Connection Management COM I is applied in this example and then click OK Connection Management cont Cancel all 2 Start Communicating Click Main Menu gt Control gt Connect and the system can communicate with the unit In this case you can check the data of units 2 Gree AC Eudemon 2009 System S View V Control C Tools T Help H E dde En ul Network n X Device COM 1 Module 1 Duct 1 B We NetworkView yee ee e ts ear dus e COM Ultraviolet Off S Module 1 Indoor Fan Low Duct Lock long distance contral Lock Swing left and right OFF Swing up and down Off Sleep mode OFF Long distance shield save s Shield Dry OFF Controller boot state Wait Forbid the assistant heat Forbid open Supper OFF Long distance shield tempe Shield Long distance shield mode Shield Long distance shield on or oft Shield Timer cancel No cancel Lock key state Unlock Clear dust clear No Prevent Frost 1 run OFF Fan valve close Flag One or more valve open Fan valve online Flag No New wind Fan valve switch OFF Water pump OFF Card state Pull out Gate System Have Prevent Frost run OFF System Information 05 16 2011 12 28 35 Connect COM 1 1 05 16 2011 12 28 35 Link state COM T Module 1 Natural NN ccce DEEE T
15. comi Module 1 o Device Views Gate System Have Prevent Frost 2 run OFF SetTemp 20 C Ms System Information 05 16 2011 13 45 40 Connect COM 1 05 16 2011 13 45 40 Link state COM T Module 1 N atural System Information The interface is composed of 6 parts Menu bar toolbar device views device set public information system information and status bar Menu bar Menu bar is a way to operate the whole system With it you can configure and manage the system as well as read the helps document Toolbar Buttons in the toolbar are some configurations and operations used most frequently in the main menu They are convenient for it 1s not necessary to switch to menu frequently Device Views It is divided into 3 kinds of display Network Position and Group presenting the engineering structure clearly and logically Select Network and you will reach physical structure of engineering Select Position and you will reach actual location of engineering e g floors and rooms where units are located Select Group and you will see all the groups and the devices inside Device Set Public Information It displays the current running state of the selected equipment System Information It displays the information of running information of users operation and malfunction information Status bar It displays the current state of the system such as name of user timer and so on 17 Engineering Configuration B
16. ding parameter of timing control command you can also enter some words in Remark column which is no more than 15 characters to mark down the usage of the command and then click Add Delete timing control command Select an item in Show District and click Delete Timing control commands can be seen in Show district If certain timing control command is overtime it will be green Users can check timing control commands according to date or equipment group To check the details of the command select it and click View or just double click on it 26 Notice To operate timing control it is necessary to ensure that the system is communicating with the equipment and timer is enable at the moment of setting timing control command The state of current timer is Shown in the status bar as below Ready User Name admin Timer Enable Click Menu gt Control gt Enable Timing Control to make timer enable Click Menu gt Control gt Disable Timing Control to make timer disable There are two modes to add timing control command One is no circulation the other is circulation 1 No circulation means you just can set a date to execute timing control command 2 At circulation mode you can set timing control command to execute according to period or the long term circulation a At period mode you can also set timing control command to execute according to day or week or month b Long term circulation means the timing control command
17. e is protected by copyright laws and international conventions Anyone who copy or spread this procedure or any part of it without authorization should bear serious penal and civil sanction and should be sued in the range of laws Copyright 2004 2011 Gree Electric Appliances Inc of Zhuhai All rights reserved Address Gree Electric Appliances Inc of Zhuhai West Jinji Road Qianshan Zhuhai Guangdong Postcode 519070 End User License Agreement Please read the rights and limits in End User License Agreement of this software Agreement carefully Before nstallation you need to read this Agreement carefully and decide whether accept the articles in it or not Unless Not until you accept all the articles in this Agreement you can not install this software on your computer For your reference you can print out the Agreement from this page on or read the DUPLICATE of Agreement in Help menu of this Software This software includes computer software and MAY includes relevant printed materials Once you have installed the software it means that you agree to be restricted by the articles of this Agreement If you do not agree with the articles of this Agreement you can not install or use this software This software is protected by Copyright Laws and International Copyright Conventions and other laws and conventions of intellectual property According to the right This software can only be for using purpose but forbidden from selling or o
18. efore monitoring users have to select a project Click Main Menu gt System gt Engineering Configuration and the following interface will show Engineering Configuration Choose Project Bais Project Identity Project Name Country Province City Area Principal Telephone Mobile Phone E mail Note the project identity have to be unique Select a project in the list of Choose Project and click OK to finish the operation If a project needs to be changed select the project to modify related information and then click OK After a project is selected 1t 1s necessary to add equipments to the project Users can examine the equipment by themselves For details of adding equipment please refer to the next chapter If users have chosen a project before the system will record it automatically It is not necessary to select a project again 18 System Configuaration Configure the protocol and bus supported by the system Only when the supported protocol 1s selected in the system configuration and the bus is added there will be resource available for Bus Configuration Click Main Menu gt System gt System Configuration and the following interface will show System Configuration Protocol Choose protocols Protocol Name TE Modbus Select all Cancel al Fis AI COM numbers COM Number COM avertime 1500millisecond Overtime 1500 milliseco
19. l or right click the device views then the control interface of the selected equipment will be shown as below Control interface of equipments may be different Control Inner Control Range Device Pork 2 Comm Module 1 IDLI2 Irun ipua _ IQUS ipue Tu Tous Ire Jitu turi iui 1pui3 Ip ipuis JIDU16 Al Control Options Power Swing Power Save Cocl Power Save Heat Shield Power Save Shield Temp Shield Mode Shield Power Lock Con Con LC ON CONES CONES YES COVES YES Setting Temp 27 SC Made C3 Cool Dry Fan Speed Auto CO Low O Fan gt Heat C3 Middle C3 High Cooling Min 27 SS Heating Max 27 SC m After each parameter is set click OK to start controlling 25 fl Cancel Timing Control Users can control the equipment or group in fixed time ATTENTION please make sure the current system time is correct before operaion by clicking Menu gt Control gt Timing Control or use right click in Device Views The system will enter into the following interface Timing Control Establish Circulation Period Remark Mo Circulation Execute Date Gite 011 Show District Please select a wav to display Date ID Address Period Hobe timing control valide only when connected Add timing control command create and set correspon
20. n All Identities Choose Identity B Pin Ev Ades e Add New Bus Indentity com Automatic Detection I Configure automatic detection click Main Menu gt System gt Automatic Detection Configuration Automatic Detection Configuration Choose a port number that is going to operate automatic detection bk we KEE COM COMO Save Cancel In this example COM 1 and Modbus are selected as the above figure and then click Save 2 Automatic Detection click Main Menu gt Control gt Automatic Detection and the system will start automatic detection Automatic Detection Automatic d tection is running and it takes several minutes Please wait For a while 13 3 The result of duct in the example is as below pay attention to the Network View on the left f Gree AC Eudemon 2009 nx System S View V Control C Tools T Help H RON WR NER NNI AR MH Network m X Device Device Set Public Informa a x W NetworkView a com t Modulef1 gt Device 1 System Information nx Network Position Group 4 x CGradate E Operation Ready User Name admin Timer Enable So far the equipment is added successfully Equipment Management 1 Rename the equipment left click Equipment to select Rename Network n x Devi Ww Network iew E com a Medulert Choose Delete Unit Control Timing Control 2 Fill in the name Duct Unit Rename Please enter a new n
21. nd Add Update Delete Protocol configuration Select the protocol to be supported in the list of Choose protocols and the selected protocol will be used for automatic detection configuration Users can add protocol and fill in the protocol name in the editing interface of Protocol Name Bus configuration List of All COM number will display the COM supported by the system currently and the corresponding overtime interval Overtime interval is a standard used for judging whether there is communication malfunction between computer and the unit ADD EQUIPMENT Bus Configuration Bus it refers to the communication link between system and equipment for data exchange For example a COM is a bus The equipment must connect to the bus before it is monitored by the system Bus identity the name used for identifying a bus Click Main Menu gt System gt Bus Configuration and the following interface will show 19 Bus Configuration All Identities Address COM 1 Add New Bus Indentity Busi L Add bus Name a Bus Identity then choose a COM and click Add Renew bus fill in the bus identity to be renewed in the editing box of Bus Identity Select a COM and click Update Delete bus Select the bus to be deleted in the list of Choose indentity and click Delete Notice if equipment is added to the bus the deletion of bus will lead to deletion of related equi
22. nt a Role Management R Engineering Confiauration E Bus Configuration B Unite Installation Configuration Automatic Detection Configuration A System Configuration S Exit X e Login to enter into the interface for login Users can log in and access related operation e Connection Management to manage the bus and decide using which bus for monitoring in the running e User Management to enter into the interface of customer management where you can add delete and renew all users e Role Management to add and delete character e Engineering Configuration users can configure project information through this menu e Bus configuration to add and delete main wire for the system e Units Installation Configuarion define the specific location of added equipment e Automatic Detection Configuration configure automatic examination through this menu e System Configuration configure the system information such as protocol and COM supported by the system e Exit to exit from the procedure View Menu Each item of the view menu controls the layout and appearance of the interface View V Contral C Tools T Help H Device Views V b v Organized By Network Device Set Public Informaton P FI Organized By Positan P 7 d V System Information l Organized By Groups G iv Toolbar T d status Bar S Application Look A e Organized By Network the
23. nt will be displayed in The equipment defined Click Add to finish the operation Notice the same unit name could not be applied to different equipments Input Unit Name Unit Name Delete unit select the unit to be deleted in the Unit Name and then click Delete MONITORING Connection Management After users add bus and equipment to the engineering he must define which bus is used for communication in certain monitor Click Main Menu gt System gt Connection Management and the following interface will appear Connection Management rose ai com Cancel all Select the COM to be linked in the list of all COMs of current engineering and then click OK Connect Equipments Connection Click Main Menu gt Control gt Connect or button E in Toolbar and the system will examine the equipment according to the saved link If communication is normal the area of device set public information will display parameter of related equipment Disconnection Click Main Menu Control Disconnect or button in Toolbar and the system will stop monitoring all the equipments 23 Equipment Parameters Left click an equipment to check equipment parameter If communication is normal the system will display parameter of this equipment as below EI Gree AC Eudemon 2009 El La Network AX Device COM 1 Module 1 Device Device Set Public Informa X W NetworkView
24. of spaces or contain in half width English either Remark could not be more than 30 characters Delete Groups To delete groups select one or more groups that you would like to delete 1n the group list and then click Delete Notice if group deleted the devices in the group will be removed from the group This operation cannot be undone Filter Devices There are two filter boxes machine type and floor They can be used to filter devices handily To display all devices click Reset Notice only when you have located a device in the Configuration of Installation Information the floors in the filter box would be shown 28 Manage Devices In The Group The groups that have already added before would be shown in the Groups Exist list Select a group and then the two lists below will display the devices that are in the group and not in the group respectively To assign one or more devices to a group please select them on the left and then click the first right arrow Click the second arrow to assign all the devices on the left to the group To remove devices from the group please select them on the right and then click the last arrow Click the third arrow to remove all devices on the right from the group Notice one device can assigned to no more than 3 groups If all the devices in a group are removed from it or deleted the timing control commands to the group if exist will be deleted too Commit Changes When OK clicked
25. ools T Help H Group Operaton G Kl 4 Group Configuration M H xXx Device Group Detection D e Group Configuration add or delete groups and manage the devices in the group e Group Control integrally control the devices in the group e Group Detection to write all the information of groups into corresponding modules Before this operation please run automatic detection first Help The Help menu offers some information about the system KS i IB e mms A 1 a LZ E H e Help documents used for entering the system e About information such as the version of the system is displayed Operation Steps The unit will introduce system operation steps so that users can intuitively understand the logical relation among each function of the system and can operate the system more easily and rapidly The system operation steps are as follows Project configuration YES System S yblerm s configuration configuration configuration Automatic Automatic detection detection YES Start monitorimg Current state e f users operate this system for the first time each step should be operated Otherwise you can start monitoring after logging in without the needs of configuration EXAMPLE Introduction This unit takes monitoring air conduit motor as an example presenting how to configure system rapidly when first using it so that the air conditioner 1s monitored User
26. pment Automatic Detection Configuration If users are not familiar with the physical structure of the equipment he can get the information such as with which units are computer connected and the quantity by automatic detection Users can monitor the unit directly with the result examined It is necessary to configure before automatic detection Click Main Menu gt Automatic Detection Configuration and the following interface will show Automatic Detection Configuration Choose a port number that is going to operate automatic detection mE Ve COM Modbus COM E Save Cancel Users select the COM to be examined and then select the protocol to be examined in the list Click Save to finish the operation 20 Automatic Detection Menu gt Control gt Automatic Detection and the system will examine the equipment according to the configuration If more than one COM and protocol are selected in the automatic detection configuration the process display will circulate several times Automatic Detection Automatic detection is running and it takes several minutes Please wait For a while When the automatic detection is working the software will show the results of automatic detection in Circulate For example System Information 057 1672011 13 41 53 0571672011 13 42 00 05 16 2011 13 42 01 05 16 2011 13 42 01 0571672011 13 42 01 05 16 2011 13 42 02 05 16 2011 13 42 02 05 16 2011 13 42 03 0571672011 13 42 03 05 16
27. r every node and terminal of this software grants the usage authorization 4 No reverse engineering reverse translation and edition or reverse compilation Do no lease rent or lend this software product 5 All the duplicates of this software must have the copyright identifier on them C Support and Service 1 Gree Electric Appliances Inc of Zhuhai offers you support and service related to software 2 Range of support and service is restricted by any policy and scheme that is defined in user s manual or other materials offered by Gree Electric Appliances Inc of Zhuhai 3 Any additional code of software that is offered to you as part of the support and service should be deemed as part of this software and should be complied with each article of this Agreement 4 The technical information which you offer to Gree Electric Appliances Inc of Zhuhai for requiring support and service purpose can be used on commercial purpose by our company including product supporting and developing Our company will not inform you individually when using these technical information except the circumstance requires us to inform you when offering you support and service D Replacement modification and update of the software 1 Gree Electric Appliances Inc of Zhuhai reserves the right of replace modify or update this software by offering you replacement version modified version or updated version of this software at any time and reserves the right of fee
28. remotely without the need to stay in the machinery room all the time e Users management of different levels e Intelligent timer control simplifies schedule management of equipment New functions e Both Chinese and English operation systems are available e Management of multiple users and roles meet the needs of various customers e Bring in engineering concept so as to visualize the operation from an abstract one e Monitor with COMs and multithreading help you monitor various unit through different COMs at the same time e Automatic examination enables you to monitor the unit fast under the state of being unfamiliar with the concept such as equipment protocol and model e Vivid network structure helps you understand the physical structure of the equipment intuitively e Vivid location structure helps you decide the location of equipment installation without the need to understand complicated physical structure e Real time record of operation and history enable you to know each operation of users for easy management Main Menu This unit will give a specific introduction to the function of procedure menu The main menu is divided into five submenus System menu View menu Control menu Tools menu and Help menu System Menu Each item of the system menu has realized some configuration function of this software system System S View V ControlfC Tools a Login L Ew Connection Management C User Manageme
29. ric Appliances Inc for monitoring and controlling air conditioners Different from the former single to single monitoring system a system can only monitor a single type of air conditioner this system is able to monitor different types of air conditioners with the capability of a system being compatible with all types of air conditioners Gree AC Eudemon 2009 has more functions and it is much suitable for users The system support users management of different levels multiple bus monitor real time control control in fixed time unit control and automatic examination With this system users will reach a more intelligent and easier remote control of air conditioners Gree AC Eudemon 2009 adopts multithreading database and COM components and so on to make the procedure structure more flexible and reliable The related components of the unit can be explored by a third party for easy expansion Both Chinese and English installation and interface are available in this system meeting the needs of different users Gree AC Eudemon 2009 enables remote control product to reach another height and it will bring you a convenient experience Copyright Declaration The copyright of Gree AC Eudemon 2009 is possessed by Gree Electric Appliances Inc of Zhuhai Any organization and individual should not copy spread or modify the information and package of this software without permission or authorization of Gree Electric Appliances Inc of Zhuhai This softwar
30. s can simulate step by step and understand each step Notice As an example this unit helps users configure this system easily and rapidly Some integrant functions are shown here and each step is explained in detail For the meanings of each function and operation please refer to the following chapter In the actual application operation is subject to actual engineering Please read each section of this chapter in order The whole process is presented in sequence Login 1 Run Gree AC Eudemon 2009 exe as an administrator in the installation catalogue The shortcut of AC Eudemon 2009 can be found in Menu Bar or desktop Gree AC Eudemon AC Eudemon 2009 2009 exe 2 The pop up interface of the software will be as below D Gree AC Eudemon 2009 E13 System S View V Control C Tools T Help H A gt ae l A Le ale Network m x Device Device Set Public Informa nx Ww NetworkView System Information nx 05 15 2011 12 26 25 Successfully retrieved today s commands of timing controll Network Position Group Ready User Name Visitor Timer Enable 3 Click Main Menu gt System gt Login Then input user name admin and password null and click Login User Name admin Password Engineering Configuration Click Main Menu gt System gt Engineering Configuration and then fill in the engineering information Click OK to finish the configuration Engineering Configuration Choose
31. s the copyright and are protected by national copyright laws as well as international conventions 4 4 You can not delete the copyright announcement from this software and you shall ensure that you will copy the copyright announcement for the duplicate of this software You should agree the restriction of unlawful duplicating this software and document in any form 5 You can not copy the enclosed printed materials of this software G Termination of authorization 1 If you do not abide by each article and condition of this Agreement Gree Electric Appliances Inc of Zhuhai can terminate this Agreement under the state of not affecting other rights Upon termination of the Agreement you have to destroy all the duplicates of this software immediately or return them to Gree Electric Appliances Inc 2 By offering you the Agreement of this software or replacement version modification version or update version you can use this software or replacement version modification version or update version of this software on the premises of accepting it Our company can terminate this Agreement So far you must have read the Agreement thoroughly and understood it well and you agree to abide by each article and condition in this Agreement INTRODUCTION Function Introduction With Gree AC Eudemon 2009 the following functions are available Traditional functions e Check the state of AC running and malfunction information e Set the parameter of AC
32. t of automatic detecting 1s water cooled screw chiller the following interface will show Users have to decide which result to be chosen as the standard It 1s recommended to select the result of automatic examination as the standard 21 Protocol Canflic It s recommended to choose the result of automatic detection Device Result OF Automatic Detection Currel See COMICI Modulet E Camel Units Installation Configuration Unit Name Name of unit where air conditioner is located such as living room and bedroom Users define the name according to the unit where AC is actually installed After adding the equipment users can define in which building which floor and which room it 1s installed so as to monitor the equipment intuitively After the unit information 1s added it will be shown on Location in Device Views of the main interface Click Menu gt S ystem gt Units install Configuration and the following interface will appear Units Installation Configuration nU Building Floor Description The equipments NOT defined The equipments defined COM Maduleti Devicet1 COMEL Modules Deviceri Add unit after filling in the information such as building floor room and description select the equipment to be added in the list of The equipments NOT defined and then click button the following interface will show Fill in the unit name and click Confirm In this case the equipme
33. ther commercial activities purpose A Gree Electric Appliances Inc authorizes the non proprietary usufruct to you Following things are within the permission 1 You can install use display and operate a duplicate of this software on a computer working station terminal and laptop or other digital electronic instruments Computer 2 You can have the backup copy ies of the duplicate in case of any destruction or waste of its substance in the duplicate This These backup copy ies can not be offered to someone else for usage by all means and you must eliminate all the duplicates when you lose the property right of these lawful duplicates 3 3 You can modify this software to apply the actual operating environment of the computer or to improve its functions and performance accordingly However unless otherwise defined in contract no one can offer the modified software to any third party without permission of Gree Electric Appliances Inc B You must guarantee following terms 1 Do not use copy modify rent or attorn this software or any content of it beyond the range of this Agreement 2 Use this software in one computer ONLY One software authorization can not be used on different computer or be used at the same time 3 Only under the following two premises can this software be applied to multi users environment or network software This software has written permission for using under multi users environment or network software o
Download Pdf Manuals