        BED SCALE 7711 - Soehnle Medical
         Contents
1.               C key   cursor up         l EE   Deletes the  cursor left        ENTER key         ast numeral        confirmation key       or character  TARE key     TEE  cursor down           ON OFF key  cursor right       ZEROING key      SPECIAL CHARACTER key    WWW Soehnle medical nl    Alphanumeric input  It is possible to make alphanumeric inputs with the  combined numeric and alphabetic character keypad     Types of input box   e Display fields  read only   e Display writing fields with numeric input option   e  Display writing fields with alphanumeric input  option    Input procedure   Numeric fields  Type in the numerals o to 9 directly  into the KEYPAD  Input is right flush  A cursor flashes  under the last digit entered  The C key clears the  numeral highlighted by the cursor  The ZEROING key  aborts the input without saving the new input values   Existing values are retained  The Enter key saves the  value typed in and returns to the application pro   gram  The setpoint  whether it is a dot  comma or  no decimal separator  is defined in Setting mode   Setting mode    Terminal    Display    Decimal sepa   rator  see p 14   Only the default number of characters  can be typed into an input box  Any other inputs  are neither displayed nor accepted     Alphanumeric fields  The numeric keys are also as   signed by multiple programming to alphanumeric  characters  upper case only  and characters  For  example  the o  zero  key is also a      and blank  character  The SPE
2.    Hold mode  p 20   Fixed tare value  p 17   General       Clear fixed tare value  p 19   Program settings Auto standby time  Plausibility check sensor  p 23 Error 12   Provisional tare  p 19   Weighing   taring     Fkey  p22  Dialysis function  p 19   Hold mode  p 20   Second unit  p 14   LM      Version  p 14  BMI function  p 20   Display  p 14   Keypad  p 14  Calibrated counter status   Date Time  p 15  approvable   Organisation data  p 15  Filter setting   User password  p 15  Zero tracking   Reset terminal  p 15  Zero range at power on     Second unit     Serial number MS     Software version MS     Data Processing Data transfer fixed values  p 18   Application    Alibi memor mi  y tpa Baud rate   Interface 1  p 21      gt       Print template  p 21      gt  printout request  1 0 port settings  Printout when W TzO  Barcode  Decimal separator    Special thousands separator    Service        password protected   Ee  Consec  no  print key    Factory setting    Only for service personnel authorised by Soehnle Professional    x WWwW Soehnle medical nl       Calling up Setting mode  Switch the appliance on  After the  power on routine  the appliance starts  the last activated application program  automatically  To call  up Setting mode first     lt    press ENTER and then the F key    simultaneously  You are now in  the Setting mode selection menu  F     Inputs in Setting mode  In most cases you can select from several different  settings available  With editable values  you 
3.  6 3 V  6 3 V    3  0080025005C70 OK  4  0080025005ADC OK    Charge run time    A battery charge is sufficient for approx  12 hrs con   tinuous duty  When the scale is switched off for most  of the time  9096 OFF   the batteries may remain in  the weighing devices for up to 125 hours before they  require a recharge    Caution  Even when the digital indicator is switched  off  the Bluetooth link is activated at regular inter   vals  For this reason  the batteries will discharge in  this state and must be recharged at the latest after  125 hours        Recommendation    Always remove the batteries from the weighing de   vices after you switch off the digital indicator and  place them in the battery box of in the charger   This makes sure that the scale works reliably the  next time it is switched on     If the bed scale remains for long period of time  without use  remove the batteries from the weigh   ing devices to prevent deep discharge  The scope of  supply comprises eight batteries     WWW Soehnle medical nl 9    ENGLISH    BED SCALE 7711    3  INPUT AND CONTROL    Keypad for input and control      KEYPAD  To enter nume     rical values or alphabetic  ORG key  Calls up     INFO key  e g  electro    characters  alphanumeric  Organisation Data     nic nameplate contai    keypad     ning reference data                o  zero  key      lt _ lt  Press several      times to display    PROFESSIONAL E y    plus      minus   INFO m  and the blank  eS character  F key  function key 
4.  Displaying the value in the tare memory   To display the tare memory  press the INFO key and  then the TARE key  Press the ZEROING key to exit  the display     Changing the tare value manually later   Display the tare value by pressing the INFO key and  then the TARE key  Enter the new value into the  KEYPAD  Press the ZEROING key to abort the input   The existing value is retained or the new tare value  is saved by pressing the TARE key  Confirm by pres   sing ENTER and return to the application program     WWW Soehnle medical nl    Error message when taring   Error 06 Taring not possible   Possible causes   e Scale empty    Scale in overload or underload  e Manual tare input with tare value above  maximum load    Displaying the tare memory  To display the tare memory  press the INFO key and  then the TARE key  Press the ZEROING key to end  the display     BMI function  The Body Mass Index  BMI  is used to assess whe   ther a person has a normal weight or is overweight   The BMI is calculated according to the following  formula     body weight  kg     BMI   body height  m  x body height  m     The unit for the BMI is therefore kg m      BMI classification separated according to gender     Cassificaion  underweight    Normal weight  Overweight 25 30 24 30  Adiposity 30 40 30 40    Severe adiposity          WWW Soehnle medical nl    Setting and using the operating mode     Setting in Setting mode Setting mode  gt  Pro   gram Settings  gt  Weighing   Taring  gt  F key  gt   BM
5.  and icons p 27  Calling up Setting mode p 15    2 WwWwW Soehnle medical nl    1  General information    Thank you for choosing this Soehnle Professional pro   duct  All the features of this product were designed to  the state of the art and are optimised for simple and  straightforward use  If you have any queries or exper   ience any problems with your appliance not addressed  in the operating manual  please contact your Soehnle  Professional service partner  or visit us on the web  at www soehnle professional com     Intended use  The appliance is designed for weighing people who  are lying down  The appliance may only be used for  this purpose  Any other use is prohibited  Messages  about errors or defects that could endanger the patient  or operator and errors that could lead to corruption of  the test results must be sent in writing to the manu   facturer s medical product adviser  see address be   low   These operating instructions as well as the  operating instructions for the 3020 Digital Indicator  are component parts of the appliance  They must  be kept near the appliance  Compliance with these  operating instructions is mandatory in order to en   sure compliance with the intended use and correct  operation of the appliance  If the appliance fails to  function correctly  the appliance may be damaged   It is essential that the appliance is then taken to an  authorised Soehnle Professional service centre  Only  genuine spare parts may be used if an authorised  servic
6.  by soiling  on the scale  The following character  appears in the icon bar when the dis   play indicates zero    o      Zero range approvable and non approved  196 to   396 of the weighing range    If zeroing is not possible  the error message  Value  above zero range limit  or  Value below zero range  limit  appears for two seconds in the display       0         x10  times 10  display  Shows the weight value with     u an additional decimal place at  20   ten times the resolution  Switch    to the x10 display by pressing    ENTER and then the ZEROING  key simultaneously  According to the calibration  law  the x10 function may only be activated on ap   provable scales for a short period of time  For this  reason  it s programmed so that the function is  switched off automatically after 5 seconds  The  message x10 appears in the icon bar as long as the  10 time higher display is selected  When the app   liance is switched off  the function is deactivated     WWW Soehnle medical nl    Weighing and taring    Display view       Weighing with measured tare  Determine and tare a bed weight without patient   Position the empty bed  including bedding  on the  scale  Press the TARE key  The tare value is saved  and the weight display goes to zero  Now the pati   ent can be laid on the bed  The weight is displayed  with the message  Net      Displaying the value in the tare memory   Press the INFO key to display the tare memory and  then the TARE key  Press the ZEROING key to termi   
7.  computer  may  be connected to the serial data port if they conform  to European Standard EN 60601 1 or a suitable dis   connecting device is connected in series     Applicator  The scale does not have an applicator  No part is in   tended for direct contact with the patient  Leakage  currents were measured on the weighing devices in  compliance with classification of Type B applicators     Operating concept  The appliance is operated by means of the keypad   The keys are assigned with different functions de   pending on the various modes     Maintenance and service  The measuring inspection test was performed during  the initial calibration process in production  Further  regular measuring inspection tests  recalibration  must  be carried out by the calibration authorities respon   sible in compliance with national regulations  Repairs  may only be carried out by a centre authorised by  Soehnle Professional using genuine spare parts   The medicine device is equipped with a non de   tachable power line  The power line may not be ex   changed by maintenance personal     Cleaning  Before cleaning  disconnect the appliance from the  mains by removing the power plug from the wall  socket  Only clean the appliance using a moist cloth   On no account may water be allowed to enter into  the appliance  Disinfectant may only be applied to  the membrane keyboard for the display  It is prohi   bited to spray the appliance and the power plug   The following disinfectants are permitted  
8.  numeral     CE mark of conformity with year of affixing and simul   taneous commencement of validity of calibration    Precision class  No  of EU approval  Manufacturer s product number    E g  0102  Official Code of  Office Quoted    this body performed the initial calibration process     27    ENGLISH    BED SCALE 7711    Load Cell    SN H2509xx  Typ SEB46B 300 C3 MR CC 6L    Soehnle Professional GmbH  amp  Co  KG           PROFESSIONAL  c   Typ 7711  SN 771110070001 BT 008025005BBF  IP X2 6V 80 mA  Soehnle Professional GmbH  amp  Co  KG           28       SN    TYP    BT    IPX2    6V DC    80mA    Symbol for EU calibration  The calibrated counter status indicates how often  the scale was calibrated  The stored counter status    must match the calibrated counter status on the  inserted label secured by adhesive label     Serial number of weighing machine    Product number der Lastaufnehmer    Bluetooth Address    Protection Class    Power Supply    Power Input    Attend to user manual  ISO 7010    Equipment for not ionized radiation  IEC 60417    Functional earth  IEC 60417    WWW Soehnle medical nl    
9.  pressing the C key    e The gap in the consecutive number scheme is  closed  The following fixed tare value memories  are given a number reduced by 1     CAUTION  Under Setting mode  gt  Program Set   tings  gt  General  gt  Delete fixed tare values  all  fixed values are cleared from the memory     Provisional tare dialysis function    Setting and using the operating mode     Setting in Setting mode   Setting mode  gt  Program Settings  gt  Weig   hing   Taring  gt  F key  gt  Dialysis function    e Press ENTER and the F key simultaneously to  access Setting mode    e The arrow points to  Program Settings   Press  ENTER to confirm    e Press TARE to browse down to  Weighing   Ta   ring  and press ENTER to confirm    e Confirm the message  F key  by pressing ENTER    e Press TARE  down  or the F key  up  to browse  to  Dialysis function  and press ENTER to confirm   There is an acoustic acknowledgement     e Exit Setting mode by pressing the ORG key  The  gross value is displayed     Using the dialysis function   e Press the F key  with a load on the scale   Mes   sage   Place tare   Place the additional tare on  the scale  Confirm by pressing TARE  The addi   tional tare is accepted into the tare memory and  the net value remains unchanged    e Repeat this procedure for other additional tares   The weight is displayed with the message  Net    When the scale is clipped off  the tare weight is  displayed with a negative sign      Clear the tare by pressing the ZEROING key    
10.  to be con   nected    e Press ENTER to confirm     Connection options  factory setting      none   2795 11  Soehnle Professional printer   2795 12  Soehnle Professional printer   Data Processing  PC    Barcode  barcode reader   Large format   display S302  monitor     Info about printer   Soehnle Professional printers are stored as standard   However  you can also set up other printers using  the 3020 3030 Service Software  Other parameters   baud rate  data bits  parity and XON XOFF  can be  assigned as specified in the printer manual  Please  contact service personnel authorised by Soehnle  Professional  The parameters set at the factory are  configured for Soehnle Professional printers     WWW Soehnle medical nl    Default print templates  factory setting   The print command keys can be assigned using the  print templates in the service software  In the fac   tory setting  the print template below is already  stored and assigned  In other words  it can be prin   ted out  This default print template is an example  showing what parameters are available     Date  Time  Scale no     Gross  Tare    Print command conditions  The print templates are assigned to print command  conditions using the service software     The following conditions can be assigned to   print templates    e Print key  ENTER    e Automatic print data record once immediately   e Automatic print data record once after weight  change at standstill   e Automatic print data record after weight  change at stan
11. CIAL CHARACTER key is also avail   able    After pressing a numeric key twice within one se   cond  this activates a rolling function to access a  character assigned to this key  If you do not press  the key a second time within one second  the cha     WWW Soehnle medical nl    racter pressed is accepted and the cursor moves   on to the next position    Numerical inputs can be made in direct succession  without any waiting period  as long as the same  number key is not pressed several times in successi   on  A cursor flashes under the last item entered   Press the F key and the TARE key to move the cursor  to the left or right  The C key clears the last character  on the left of the cursor or the character with the  cursor flashing underneath it     The ZEROING key aborts the input without saving  the new input values  Existing values are retained   The ENTER key saves the value typed in and returns  to the application program  Only the default number  of characters can be typed into an input box  Any  further input overwrites the last character     ENGLISH    BED SCALE 7711    Indicator display Icons characters  The display shows a number of different views de  Icons in the icon bar  pending on the situation  It is divided into display  panes     Alibi memory capacity 10096       Additional display Icon bar Alibi memory capacity 8096  Alibi memory capacity empt  Display panel a d   Keylock   Additional display     It displays BMI  Gross  Net  etc  If required  it can be H   
12. FOR MEASURABLE SUCCESS PROFESSIONAL       BED SCALE 7711        OPERATING MANUAL    WWwW Soehnle medical nl       ENGLISH    BED SCALE 7711    CONTENTS    1 General information P3 Inputs in Setting mode p15  Intended use D3 Settings in Setting mode p15  CE sign D3 Settings in  Program Settings  menu D 15  Classification p3 Settings in  Terminal  menu p 15  Safety instructions p 4  Use of additional devices p 4 Functions pg  Applicator DG Power on zeroing p17  Operating concept DG Manual zeroing pi  Maintenance and service p 4 x10  times 10  display p17  Cleaning DG Weighing and taring p17  Disposal DG Weighing with measured tare p17  Note p5 Weighing with manually entered tare p 18  Warranty  liability p5 Weighing with stored tare values p 18  Provisional tare dialysis function p 20  2  Putting into operation p7 Error messages when taring p 21  Installing the scale elements P7 Displaying the tare memory p21  Power on D7 BMI function p 21  Radio link p8 Hold function p21  Power on   Power off p8 Print p 22  Charging the batteries p8 Programming the F key p 23  3  Input and control p 10 Error messages p 24  Keypad for input and control p 10  Alphanumeric input pii Technical information p 26  Indicator display p12 Technical data p 26  Icons characters p i2 Other technical data p 26  Instructions for installing the scale p 26  4  Setting mode p 13 Electronic nameplate  Keypad in Setting mode p 13 and calibration counter p 27  Overview of menu navigation p 14 Explanation of labels
13. I function    e Press ENTER and the F key simultaneously to  access Setting mode      The arrow points to  Program Settings   Press  ENTER to confirm    e Press the TARE key to browse down to  Weig   hing   Taring  and press ENTER to confirm    e Confirm the message  F key  by pressing ENTER    e The arrow points to the last function activated    e Press the TARE key to browse to  BMI function   and press ENTER to accept  A beep tone confirms  acceptance    e Exit Setting mode by pressing the ORG key  The  weight value is displayed     Using the BMI function   e Press the F key  The following message appears    Enter body height   Enter your body height in  metres    e Confirm by pressing ENTER  Now  parallel to the  person s weight  the BMI value is displayed in  the additional display    e The BMI display can be switched off by pressing  the F key again     Hold function    Setting in Setting mode   Setting mode  gt  Program Settings  gt  General   gt  Hold mode   The Hold function  Hold mode  freezes the measu   red value in the display dependent on the selected  setting  The following settings are possible     ENGLISH    BED SCALE 7711    not active  Hold mode is off   Still Key  Value freezes   Press the ON OFF to cancel Hold mode   Still Empty  Value freezes   Clip off the scale to cancel Hold mode   Max Key  Max  value freezes  at standstill    Press the ON OFF key to cancel Hold mode   Max Empty  Max  value freezes  at standstill    Clip off the scale to cancel Hold m
14. M Multirange Multidivision 1   switched on with the F key according to the program     settings     Multirange Multidivision 2   Icon bar Multirange Multidivision 3       Shows information about the status of the active    measuring point  Resolution x10  10 times        Display panel Mi Zero  Shows weight value and unit characters   Hold function active       Unit character    Symbol for standstill   After placing a load on the scale  bed  patient  etc      the scale requires time to finish oscillating  Until it  comes to a standstill the unit character  kg  Ib  re   mains blank  The unit character only appears when  the scale reaches standstill and a stable value is  obtained  clip off      WWwW Soehnle medical nl    4  SETTING MODE  Keypad in Setting mode    ORG key     Exits the Setting    mode      PROFESSIONAL    INFO    Max Min e     Setting mode        b Program settings    cales    F key  Moves the marking    arrow up the list or moves    the cursor to the left      T key  TARE key      Moves the marking arrow    down the list or moves the           PRINT ENTER key      Calls up the marked     menu option or saves  t an input or change    cursor to the right       i ZEROING key  Returns    to the next higher level     back without saving    the change     WWW Soehnle medical nl      KEYPAD       key      Clears the     last numeral   character      ON OFF key    ENGLISH    BED SCALE 7711    Overview of menu navigation  The following setting options are available     
15. can type  in values into the numerical or alphanumeric keypad     Settings in Setting mode  With the parameters in Setting mode  you can  adapt the weighing and taring application program  to your specific requirements        Settings in  Program Settings   menu  In the  Program Settings  Settings menu  you can  adapt the Application program of your scale to your  specific requirements   the bed scale mainly uses   Weighing and taring      www soehnle medical nl    Settings in  Terminal  menu  In  Terminal  Setting mode  you will find the follow   ing request and setting options     Version   AZG software version Display only  AZG applications software Display only  AZG serial number Display only  CPU board serial number Display only    Display  Backlight Sets the luminosity  enter  as a percentage into the  numerical keypad  0    dark   100    fully luminosity   factory setting  80   Contrast setting  enter as  a percentage into the nu   merical keypad  1  is low   est contrast  100  is full  contrast  factory setting 50   Deutsch English Fran  ois  Comma  point or none  Factory setting  comma    Contrast    Language  Decimal separator    Second unit g t Ib mg oz  additional  field in display    Keypad   Keylock Individual  several or all    keys on the keypad can be  locked  Press the key to be  locked to change the status  of the key from  unlocked   to  locked  and vice versa     ENGLISH    BED SCALE 7711    Keytone    Validation tone    Date time    Time    Date  Date fo
16. dstill   e Automatic print data record after weight  change at standstill above the empty message   e Automatic print data record after weight change  at standstill above the empty message if the  active empty message was previously active    e Continuous transmission   e ENTER Accept key when ORG A is entered   e  ENTER Accept key when ORG B is entered   e  ENTER Accept key when ORG C is entered    www soehnle medical nl       e ENTER Accept key when ORG D is entered   e Key combination INFO  F and ENTER   dependent on settings       ENTER Accept key for manual input   e Print alibi memory    Programming the F key  The F key is programmable to call up various func   tions  It assumes different functions depending on  how it is assigned  The current function is selected  in Setting mode   Access Setting mode by first pressing ENTER and  then the F key simultaneously   In Setting mode you will find the F key program   ming options under Program Settings  gt  Weighing    Taring    F key   Select the required function by pressing the F or  the TARE key and confirm by pressing ENTER     The following functions are available   Provisional tare  Dialysis function  Hold mode  Second unit  BMI function    Exit Setting mode by pressing the ORG key     23    ENGLISH    BED SCALE 7711    6    05    06    07  08  09  10  11    12    13  15  16  18    20    Error messages    Error numbers  gt  Cause   Remedy   Info    Zeroing not possible   gt  Deviation from zero point too large    Tarin
17. e charger itself        LED status indicator on charger  for each charge   compartment        LED lights up orange  battery still charging     LED lights up green  battery charged   trickle  charge    LED status indicator on weighing device   Digital indicator is switched on  radio link active      LED lights up green  battery charged    First exit the editing section before switching the scale S LED flashes green  mainly on  off for short    off   The weighing devices have no on off switch  They are  only switched off when the batteries are removed     OFF display   When the scale is switched off but remains connected  to the power supply  the indicator display shows   OFF   in accordance with the Medical Equipment  Directive      periods  battery still has sufficient capacity  for normal operation   LED flashes green  normally off  only on for  short period   battery almost empty  battery  must be recharged    Digital indicator is off or in standby mode    s LED lights up green for approx  2 mins    and then starts to indicate standby mode  by flashing  mainly off     The charging time for empty batteries is approx  4  hours  Batteries should be charged and exchanged  in sets  The batteries may remain for any length of  time in the charger when it is on     8 WWVW Soehnle medical nl    Display of link state   Press Info key   1  The following appears in the  indicator display     Weighing device State  1  0080025005BB7 OK  2  0080025005CoD Error    Battery voltage  6 3 V   
18. e station carries out repairs  These genuine  parts are described in the service documentation   Spare Parts List  470 014 037 Scale   470 630 273  Digital Indicator   470 014 038 Weighing Device   including Order Number     Soehnle Professional will only assume responsibility  for the safety of the appliance if these instructions  are observed and the appliance is operated in com   pliance with the operating instructions  The appliance  is a medical device and may only be used by persons  who are capable of handling it correctly as a result  of their training  Before using the appliance  the  user must ensure that the appliance is functional  and in proper working order  The operator must know  how to operate the appliance  The appliance is not  intended for use in medical rooms subject to explo   sion hazards  Explosion hazard areas may occur if  flammable anaesthetics  skin cleansing agents and  skin disinfectants are used     CE sign  The product carries the CE sign in accordance with  the following directives   e 89 336 EEC Electromagnetic Compatibility  e 73 23 EEC Low Voltage Directive     90 384 EEC Nonautomatic Weighing Instruments  e 93 42 EEC Medical Cc  5   Products  Class   Typ  7711  with measurement pecans ROO  function                    Soehnle Professional GmbH  amp  Co  KG   d von Ardenne Allee 12 71522 Backnang Germany       Classification  e Class   medical product with measuring function    c  Electrical Safety Class Il   with double isolated function gr
19. g no possible    gt  Empty scale  scale underloaded or overloaded   manual tare input with tare value above max  load  Print not permitted   No mass unit switchover   Print signal buffer full   Load cell signal overflow   No measuring point signal   Check sensor position    gt  Incorrect lever setting for at least one  weighing device or no weigh on at least one  weighing device  plausibility check active   Converter failure   Measuring point write protected   No measuring point detected    Measuring point not zeroed    Print format empty    24    23    24    25    26    30    33    34    35    36    37    40         4G    Print error   Print template memory corrupt  No print template s    Printer update cancelled   Alibi memory full   Alibi memory contents corrupt  Alibi memory empty   No or defective alibi memory  Cannot write alibi   Alibi memory unreadable  General data format error    Input value too small    42 Input value too big    44 Power off not allowed    50    Value below zero range limit   gt  Zeroing not possible because measured value  is outside the set zero range limit    WWwW Soehnle medical nl    51 Value above zero range limit   gt  Zeroing not possible because measured value  is outside the set zero range limit    52 Overload   gt  Measured value above weighing range    53 Underload     Measured value below o  zero     55 Place weight on scale     Scale empty or no clip off setting made  according to set clip off factor   75 Replace backup battery   76 C
20. harge batteries   80 Abort external command   81 Timeout external command   82 Number exists already     The identification assigned to a fixed value  exists already   90 Fixed value memory occupied   full     A total of 100 memory locations are available    valid for all programs    98 Wrong barcode    WWW Soehnle medical nl 25    ENGLISH    BED SCALE 7711    7 Technical information    Technical data  Weighing range   Division    Min max load   Max  bed weight  250 kg  Approval number  Do7 09 034 PTB  0102   Ambient operating temperature    10  C to  40  C  rapid  temperature changes  e g   in the event of cold drau   ghts  may impair the test  result   40 C to  70  C  2096  8596 relative humidity   non condensing  Digital indicator power supply   power adapter mains voltage  100 240 V   50 60 Hz  Weighing device power supply   From 6 V lead gel battery   battery capacity  1200 mA  continuous duty approx  12  hours  Transportation conditions   The appliance may only be  transported in its original  packaging  comply with  storage temperature  avoid  vibrations and shocks  19 keys  function key freely  programmable  Organisation data memory   4 memories  alphanumeric  input via the numerical  keypad    see nameplate  see nameplate  see nameplate    Storage temperature   Humidity     Membrane keyboard     Display  Dot matrix 240 x 64 pixels   dimmable  backlighting  Fixed value memory for to   tal of 100 fixed values  va   lid for all programs  power  failsafe  alibi memory fo
21. hing devices are designed to re   ceive wheel diameters of 130 160 mm  Small diam   eters are optional      Power on   Power off  Switch on or off the digital indicator  by pressing the On off switch                         The message  SOEHNLE PROFESSIONAL  appears in  the indicator display together with a search icon until  the radio link is set up to the weighing devices  This  normally takes 20 to 60 seconds     When the radio link to the weighing devices Is set  up  the indicator display shows the current gross  weight value     www soehnle medical nl 7    ENGLISH    BED SCALE 7711       Radio link             The Bluetooth radio link operates over a max  radius  of 5m if there is no partition wall between the weig   hing devices and the digital indicator  After short inter   ruptions  e g  to replace a battery or caused by the  loss of battery contact due to shocks   the link is  restored automatically within a few seconds     Power off  If the sensors are overloaded or you have started a  menu  the scale switches off after you  press the On Off button for 5 seconds   It is not possible to switch off the sca   le as long as it is waiting for an input  in the editing section of Setting mode        Charging the batteries   Open the cover of  the battery charger   The charger has  four compartments  to recharge the four  batteries simultane   ously  The four LEDs  indicate the charge state for each battery  The fifth  LED on the charger is the mains power indicator for  th
22. ing up the list of fixed tare value memories  for taring   The tare value from the fixed tare value memory  can be activated with the scale unloaded  i e  be   fore the weighing operation  or with the scale loa   ded  during a weighing operation     The display pane shows a weight value 2 0 000 kg   First press ENTER and then the TARE key simul   taneously  The fixed tare value memory last used  appears in the display    Press the F or TARE key to browse to the required  fixed tare value memory or type in the memory  location number and confirm by pressing ENTER   Press ENTER to activate the fixed tare value   The display shows the gross value minus the  tare value  net     Further tare values from the memory are activated  by repeating the procedure described above     Clearing an existing fixed value    Call up the input menu    Setting mode  gt  Program Settings  gt  General   gt  Fixed tare values    Press ENTER and the F key simultaneously to  access Setting mode    The arrow points to  Program Settings   Press  ENTER to confirm     ENGLISH    BED SCALE 7711    e Confirm the message  General  by pressing ENTER   e Press the TARE key to browse to  Fixed tare va   lues  and accept by pressing ENTER     Clearing a tare value   e The last selected fixed tare value memory is  displayed  Press the F or TARE key to browse  the required fixed tare value memory or enter  the memory location number and confirm by  pressing ENTER    e Clear the displayed fixed tare value memory  by
23. methy   lated spirits  Isopropanol  296 Kohrsolin  196 aqueous  Sokrena solution  596 Sagrotan or 596 Gigasept     4 WWW Soehnle medical nl       Disposal   According to the present state of the art   the appliance contains no special environ    mentally harmful substances  This product  MM is not to be treated as regular household  waste  but should be handed in to an electrical elec   tronic equipment recycling centre  You can obtain  further details from your local council  your munici   pal waste disposal company or the firm from which  you purchased the product   Battery disposal  Do not dispose of batteries in the  household rubbish  As consumer you are obliged by  law to return waste batteries  You can hand in your  old batteries as hazardous waste to the public col   lection centres in your municipality or return them  to the firm where you purchased them  You will find  these labels on batteries containing hazardous sub   stances  Pb   battery contains lead  Cd   battery  contains cadmium  Hg   battery contains mercury   Lead gel batteries are used to power the weighing  devices  They must also be disposed of as hazard   ous waste and returned to the dealer when pur   chasing new batteries     Note   Interference suppression of the unit corresponds to  the valid EU Directive 89 336 EEC  The display value  may be influenced by extreme electrostatic and electro   magnetic interference  e g  operation of a radio unit  or a mobile phone in the immediate vicinity of the  
24. nate the display     Changing the tare value manually later   Display the tare value by pressing the INFO key and  then the TARE key  Enter the new value into the  KEYPAD  The ZEROING key cancels the input  Exi   sting values are retained or new tare values are sa   ved by pressing the TARE key  Confirm by pressing  ENTER and return to the application program     ENGLISH    BED SCALE 7711    Weighing with manually  entered tare  If the patient is already on the bed and the  bed weight is known  then this can be tared by  manual input   Enter the known bed weight  tare weight  using  the KEYPAD  The input appears in the display with  the current weight unit  Press the TARE key  The  nput is transferred into the tare memory and the  tare weight is deducted from the weight display   The patient s weight measured in this way is dis   played with the message  Net      Showing the value in the tare memory   Display the tare memory by pressing the INFO key   then press the Tare key  Press the ZEROING key to  end the display     Changing the tare value manually later   Show the tare value by pressing the INFO key and  then the TARE key  Enter the new value into the  KEYPAD  Press the ZEROING key to cancel the input   The existing value is retained or the new tare value  is saved by pressing the TARE key  Confirm by pres   sing ENTER and return to the application program     Weighing with stored tare values    Known bed weights can be stored as the tare value  in a power failsafe memo
25. ode   Delay Key  Max  value freezes  movement    Press the ON OFF key to cancel Hold mode   Delay Empty  Max  value freezes  movement    Clip off the scale to cancel Hold mode     Print  The 3020 Digital Indicator can be connected to a  printer via the serial port to print out scale chits  Up  to a max  of 15 print templates can be stored  You  can obtain a service software from Soehnle Profes   sional service centres for the 3020 3030 to design  print templates with customised contents     The parameters listed in the standard print templates  can be used to design user defined print templates   In addition  organisation data  identifiers  and user   defined parameters  such as company names  can   be included  Please contact your Soehnle Professional  service partner about your print template requirements   Start the print routine either by pressing ENTER or   by pressing another print command  e g  the F key     22    Configuring the printer port     Setting in Setting mode   Setting mode  gt  Data Processing  gt  Interface  1  gt  Application  gt  2795 11    e Press ENTER and the F key simultaneously to  access Setting mode    e The arrow points to  Program Settings   Press  the TARE key to browse to  Data Processing    Press ENTER    e The arrow points to  Data transfer   Press the  TARE key to browse to  Interface 1   Press ENTER    e The arrow points to  Application   Press ENTER    e The arrow points to  2795 11   Press the TARE  key or the F key to select the printer
26. ound   No applicator  e Waterproof to IEC529 IPX2          WWW Soehnle medical nl 3    ENGLISH    BED SCALE 7711       Safety instructions     Before putting the appliance into use   please read with care the information given in the  Operating Instructions  They contain important in   structions for installation  intended use and mainte   nance of the appliance  The manufacturer shall  not be liable if the following instructions are  not observed   In case the electrical components are used under  increased safety requirements  compliance with the  appropriate regulations is compulsory  Never perform  work on the appliance while the power is switched  on  Improper installation will render the warranty null  and void  Ensure the voltage marked on the power  supply unit matches your mains power supply  The  device is designed for use within buildings  Observe  the permissible ambient temperatures for use  Tech   nical Information   The device meets the requirements  for electromagnetic compatibility  Do not exceed the  maximum values specified in the applicable stand   ards  If you have any problems  contact your local  Soehnle Professional service partner   Warning  A change of the medicine device is pro   hibited  This device may not be changed without the  manufacturer s authorisation  If the medicine device  is changed  appropriate analysis and examination  must be undertaken to ensure a safe continued use     Use of additional devices  Only additional appliances  printer 
27. r 2  million inputs optional   1x RS 232  other interfaces  optional  Bluetooth Quali   fication   Digital Indicator  housing  plastic  weighing devices   aluminium   130 160 mm       max  width 71 mm    Memory capacity     Interfaces     Materials     Wheels    Other technical data  Diagrams  lists of spare parts  and setting instruc   tions can be requested through the manufacturer s  Customer Service     Instructions for installing   the scale  For design reasons  the scale is designed only for use  on level floors  For installation sites in Germany  this  condition is met when the floor complies with the  tolerance specifications for flat floors to DIN 18202   Table 3  Row 4  For other countries the applicable  national standards should be taken as a basis     WWW Soehnle medical nl       Electronic nameplate and calibration counter    The appliance has an electronic nameplate     INFO    inle                                     11   12 I  1 1  300kg J  500kg jJ  2kg    4kg    0 1kg   ee Max  SNR  000000 XXXXIX XXXXX  GD  D07 09 034 PTB   M 07   YP  7711   XXXX   Min  PROFESSIONAL e        C   07    ap  Do7 09 034 PTB  TYP    XXXX    WWW Soehnle medical nl    Display by pressing the INFO key  Exit the display by pressing the INFO key again      d counter 6 1   sample display     Weighing ranges   Maximum load of weighing range  Minimum load of weighing range  Calibration value  division     Scale serial number  scale type  final number of  year of manufacture  incremental
28. rmat    Organisation data  Description of ORG A    Description of ORG B   ORG C  ORG D    User password  New change    To accept  press ENTER for  3 seconds    Select  off  or  on   Confir   mation tone when a key is  pressed  Factory setting   off   Select  off  or  on  Valida   tion tone when a function  is executed  factory setting    off     Enter into numerical key   pad  Press ENTER to start  cock after confirmation  Enter into KEYPAD   Select European or imperial  date  factory setting  Euro   pean    Enter the description of the  organisation data memory  A  numerals or text entered  into KEYPAD  e g   Bed  number    Room number   max  12 characters   Further input options   for other organisation data  memories  see above    Enter password with up to  8 characters into keypad   after activation  the Setting    Clear    Reset terminal  Do not execute   Executes    mode is only accessible by  password  If you forget your  password  type in the word  CLEAR to release access   Clears the password and  releases access     Execute  clears all   all the individual terminal  settings and resets to fac   tory settings    WWW Soehnle medical nl       5  FUNCTIONS    Power on zeroing  During the power on procedure  the weight values  sent by the weighing devices are zeroed until they  are less than 50  of the max  weighing range  This  tares the empty bed and the weight display goes  to zero     Manual zeroing   Manual zeroing corrects minor devia   tions from zero  e g  caused
29. ry and called up as required   100 different bed weights are possible      Each memory location has a    e  Three digit consecutive number  e Description  text  18 characters   e Tare value    18    Entering tare weights into the fixed tare   value memory   e Call up the input menu   Setting mode  gt  Program Settings  gt  General   gt  Fixed tare values    e Press ENTER and F key simultaneously to access  Setting mode    e The arrow points to  Program Settings   Confirm  by pressing ENTER    e Confirm the message  General  by pressing ENTER    e Press TARE to browse to  Fixed tare values  and  accept by pressing ENTER     Entering values   e  f no tare memory has yet been assigned  the  first free  or otherwise the last  selected fixed  tare value memory is displayed    e Press ORG followed by ENTER  The input field  for the description of a new tare memory is dis   played    e tnter the description into the KEYPAD and con   firm by pressing ENTER    e The arrow points to  Tare value   Press ENTER   The input field is displayed to enter the tare value    e Enter the tare value and confirm by pressing  ENTER    e Go back by pressing the ZEROING key to select  the tare memory    e  f you want to assign other tare memories  press  the ORG key to select the next free memory lo   cation and repeat the procedure as described  above    e To return to weighing mode  press the ZEROING  key and then the ORG key     WWW Soehnle medical nl    Transferring fixed tare values from a PC to 
30. s  unsuitable  or improper storage or use  incorrect installation or   putting into operation by the owner or third parties   natural wear and tear  changes or modifications  in   correct or negligent handling  excessive use  chemi   cal  electrochemical or electrical interference or hu   midity  unless this is attributable to negligence on the  part of Soehnle Professional  If operating  climatic or  any other influences lead to a major change in con   ditions or material quality  the warranty for perfect    WWW Soehnle medical nl 5    ENGLISH    BED SCALE 7711     a ee    unit functioning shall be rendered null and void  If   Soehnle Professional provides an individual warranty   this means that the appliance supplied will be free   from faults for the duration of the warranty period   Always keep the original packaging in case you have  to return the scale     6 WWwW Soehnle medical nl       2  PUTTING INTO OPERATION    Installing the scale elements  The indicator s placement must allow for a simple  disconnection from the power supply   Insert rechargeable batteries in all four weighing  devices  When the batteries are fitted  the weighing  devices start to send and attempt to set up a radio  link to the digital indicator     Caution  Fig 1 4 right     Before switching on the scale  place the weighing  devices under the four wheels of the hospital bed   Push the weighing devices as far as the stop under  the wheels  Press the lever down and raise the bed  wheel   The weig
31. the  digital indicator    Here you require a special software  For more  information  please contact the Soehnle Profes   sional Service personnel     Changing or overwriting a fixed tare value memory    Call up the Input menu    Setting mode  gt  Program Settings  gt  General   gt  Fixed tare values    Press ENTER and the F key simultaneously to  access Setting mode    The arrow points to  Program Settings   Confirm  by pressing ENTER    Confirm the message  General  by pressing ENTER   Press the TARE key to browse to  Fixed tare va   lues  and accept by pressing ENTER     Correcting values   The last selected fixed tare value memory is dis   played  Press the F or TARE key to select the tare  memory to be changed or enter the memory lo   cation number and confirm by pressing ENTER   Press ENTER  The input field for the tare location  description is displayed    Change the description by typing it into the  KEYPAD and confirm by pressing ENTER    The arrow points to  Tare value     Press ENTER  The input field for the tare value  is displayed    Change the tare value by typing it into the KEY   PAD and confirm by pressing ENTER    Go back to the tare memory selection by pressing  the ZEROING key     WWW Soehnle medical nl    If you want to change other tare memories   press the F key of the TARE key to select the  next memory location to be changed and repeat  the procedure as described above    To return to weighing mode  press the ZEROING  key and then the ORG key     Call
32. unit  When electrostatic interference is no longer  present  the appliance can again be used for its in   tended purpose  You may need to switch it on again   The appliance is a measuring instrument  Air currents   vibrations  rapid changes in temperature and direct    sunlight may have an effect on the accuracy of the  scale  The scale is protected to IP 54 protection class   Therefore  avoid high levels of humidity  vapours   aggressive liquid media and strong contamination     Warranty liability  If the appliance is delivered with a fault or defect  which is within Soehnle Professional s scope of re   sponsibility  Soehnle Professional is entitled to either  repair the fault or supply a replacement appliance   Replaced parts remain the property of Soehnle Pro   fessional  Should the fault repairs or replacement  delivery not be successful  the statutory provisions  shall apply  The period of warranty shall be 2 years   beginning on the day of purchase  Please retain your  receipt as a proof of purchase  If your scale requires  servicing  please contact your dealer or Soehnle Pro   fessional Customer Service  Only genuine spare parts  may be used if an authorised service station carries  out repairs  Soehnle will only assume responsibility  for the safety of the appliance if these instructions  are observed and the appliance is operated in com   pliance with the operating instructions     No responsibility shall be accepted for damage   caused by any of the following reason
    