1. Epsilon SAS Model SAS17E O 0 0 0 0 0 0 0 0 a 0 0 0 0 0 2 ofe User s Manual 1 7 EPSILON Switch amp Amplifier System E 1 7 2 SAS36E SPECTRACOM SYNCHRONIZING CRITICAL OPERATIONS Epsilon SAS Model SAS36E 9 0 0 0 0 0 09 O 0 09 0 09 0 9 O uno mol LOTION 00 90 O mA A 0 0 0 0 9 020 O Spectracom Corporation User s Manual Spectracom Corporation EPSILON Switch amp Amplifier System E 2 Features 2 1 Main Power Supply Main power connector CCE22 with ON OFF switch Input voltage 90 to 265 V 48 to 63 Hz 60VA max Fuses 2 x 250 V 1A TD Time Delay Consumption 18 W typical Detection of power input presence on AC DC converter information available with remote control software 2 2 DC Power Supply Input power VDC 20 to 72V Consumption lt 50 W typical Protection against polarity inversion Protection against short circuit polyswitch ensures the isolation of the module in relation to the DC power supply in the event of a short circuit of the EPSILON s power supply Detection of power input presence on AC DC converter information available with remote control software Connector DC POWER XLR 3 points pins male NEUTRIX reference NC3MDH Pins settings Pin Number 1 VDC 2 VDC 3 Earth Ground The power supply must be connected between pins 1 and 2 rear panel external view Pin 1 Pin 3 Pin 2 VDC VDC Earth
2. Designed by SPECTRACOM a trademark of the OROLIA group 1 Host Name Unique name of the SAS E in the network This functionality depends on the DNS server type 2 Use DHCP Dynamic Host Configuration Protocol a Yes The Dynamic Host Configuration Protocol function available In this case the IP address of the SAS E is automatically allocated by the network DHCP server according to the SAS E MAC address The fields that follow are not used b No The Dynamic Host Configuration Protocol function isn t available A static IP address is used In this case the operator must fill in the fields that follow 3 IP Address Sub network mask Sub network address Broadcast address Default Gateway fields allowing configuration of the network access when the DHCP is set to No 4 Change password Field for password modification This password is required when accessing setup pages 4 8 User s Manual Spectracom Corporation EPSILON Switch amp Amplifier System E When set in Use DHCP mode if the SAS E starts without a network connection the IP address is not set After the network connection is restored a 1 or 2 minute delay occurs before the IP address is assigned User s Manual 4 9 EPSILON Switch amp Amplifier System E Spectracom Corporation 4 1 6 SNMP and Traps Setup Page In this page the operator can enable the SNMP Traps generation The SNMP traps report an event alarm or configuration modification by sending
3. Use NTP Server is disabled Helpful for fine adjusting manually set time 4 14 User s Manual Spectracom Corporation EPSILON Switch amp Amplifier System E 4 18 Tools 4 1 8 1 Event Logging This page displays the recording of events detected alarms warning information within the SAS E Only the information in the MIB Get information is logged D S PUE G TRA Ce O M Synchronizing Critical Operations Events Logging Display Filter F Information M Warning Alarm Max lines 10 y Update list Ci Mic Time Module Gravity 30 11 1999 00 02 26N SASE Information Channel B to Channel A 30 11 1999 00 02 26N SASE Information Channel Selection Source is Network Clear logs 30 11 1999 00 00 29N SASE Information Channel B to Channel A 30 11 1999 00 00 29N SASE Information Channel Selection Source is Network 30 11 1999 00 00 33N SASE Information Channel B to Channel A 30 11 1999 00 00 33N SASE Information Channel Selection Source is Network lt lt lt 141 gt gt Designed by SPECTRACOM a trademark ofthe OROLIA group Display Filter select the required type of displayed event on the log panel Max lines defines the number of events per page to be displayed lt lt lt gt gt gt Buttons Navigation through the screens Update list button Refresh display User s Manual 4 15 EPSILON Switch amp Amplifier System E Spectracom Corporation 4 1 8 2 Version
4. J10 J11 J9 J10 J11 Core Sine wave signal J12 J13 J12 J13 if external clock A selected J2 input frequency J14 J15 J16 J2 input level 10 J17 J18 J19 if external clock B selected J25 input frequency J20 J21 J25 input level 10 Braid electrical ground 1PPS_Out J14 J15 J16 J27 J28 J29 BNC Female J17 J18 J19 J30 J31 J32 Core Periodic pulse J20 J21 J33 J34 if external clock A selected J1 input periodic pulse J35 J36 J37 if external clock B selected J26 input periodic pulse J38 J39 J40 High Level gt 2 4V load 50 Q J41 J42 Low Level lt 0 7V load 50 Q Braid electrical ground ToD_Out J5 J22 J5 J22 Mini Din 6 pins Female Pin number 1 Reserved 2 Reserved 3 Electrical ground 4 NC 5 Electrical ground 6 if external clock A selected J3 input ToD RS232C if external clock B selected J24 input ToD RS232C External J5 J22 J5 J22 Mini Din 6 pins Female Signals_Out Pin number 1 if external clock A selected J3 input External_signal 1 if external clock B selected J24 input External_signal 1 2 if external clock A selected J3 input External_signal 2 if external clock B selected J24 input External_signal 2 3 Electrical ground 4 NC 5 Electrical ground 6 Reserved User s Manual 2 3 EPSILON Switch amp Amplifier System E Spectracom Corporation 2 5 Urgent Alarm Connector Universal Serial Bus USB connector A series URG
5. This page displays the version number of key elements of SAS E software and firmware D SFECIRAGOM Synchronizing Critical Operations SAS E Version Archive Version Actual Version Software Version System Version Actual Version 01 07a Date 04 01 2008 14 49 41 Hardware Version Carte 100 01 Designed by SPECTRACOM a trademark of the OROLIA group 4 1 8 3 Software and Firmware Upgrade Software and firmware upgrade is performed with this Upgrade Application page Two steps are necessary First Upload a New Release and then Activate New Release Before starting the upload new version process select the file to be downloaded usually a tgz file provided by the manufacturer Click on the Upload button to proceed 4 16 User s Manual Spectracom Corporation EPSILON Switch amp Amplifier System E D SPECT EAC OM Synchronizing Critical Operations guration us Tools Upgrade Application Upload a New Application Version It should be an sase_wooctgz with an install sh included It should not be higher than 4000 ko Then Upload File The tranfert can take up to 5 minutes Application Version Choose a New Version for Application and press Install New Version bouton This erase current Application and replace it with a New version New Version Actual Version 01T09b Date 09 01 2008 17 31 01 Install New version Delete File File na y Delete Designed by SPECTRACOM a tradem
6. Amplifier System E Other LEDs LED green AC e ON when AC power is monitored and present e OFF when AC power is not monitored e OFF when AC power is monitored and not present in this case Non Urgent alarm is active LED green DC e ON when DC power is monitored and present e OFF when DC power is not monitored e OFF when DC power is monitored and not present in this case Non urgent alarm is active LED green Eth ON when the SAS E is connected with a network LED red Alarm nurg ON when a non urgent alarm is generated LED red Alarm urg ON when a urgent alarm is generated 3 5 Alarm The Non Urgent alarm is generated when o Only one channel is detected fail in the case of both channel are monitored and the SAS E is not forced on the faulty channel The output signals are still nominal o Both channel are monitored and there are fail o A default on a supervised power AC or DC The Urgent alarm is generated when o The SAS E is forced on a channel and this one is detected as failed o Both channels are monitored and are detected as failed o Atleast one output is detected as failed On each alarm connector and in case of an active alarm o The contact relay between Pin 1 and Pin 2 is closed User s Manual 3 5 EPSILON Switch amp Amplifier System E Spectracom Corporation o The contact relay between Pin 3 and Pin 4 is open 3 6 Powering Down To switch off the SAS E place the main power swi
7. User s Manual 2 1 EPSILON Switch amp Amplifier System E 2 3 Input Signals Spectracom Corporation Connector Electrical Characteristics ESAS Frequency_In Ji BNC Female external clock A Core Sine wave signal Frequency 1 MHz up to 16MHz Level OdBm up to 17dBm Braid electrical ground Frequency_In J26 external clock B 1PPS_In J2 BNC Female external clock A Core periodic pulse period 1s High Level gt 2 4V load 50 Q low Level lt 0 7V load 50 Q Braid electrical ground 1PPS_In J25 external clock B ToD_In J3 Mini Din 6 pins Female external clock A Pin number 1 Reserved 4 NC 2 Reserved 5 Electrical ground 3 Electrical ground 6 Message input ToD_In J24 level RS232C ASCII message external clock B ALARM_In J4 Jack 3 5mm Mono Female external clock A Input for open collector current drive 0 5mA or for relay contact Braid Electrical ground ALARM_In J23 external clock B External Signals_In J3 Mini Din 6 pins Female external clock A Pin number 1 External_signal 1 4 NC 2 External_signal 2 5 Electrical ground 3 Electrical ground 6 Reserved Characteristic 30VA 250V max External Signals_In J24 external clock B User s Manual Spectracom Corporation 2 4 Output Signals EPSILON Switch amp Amplifier System E Connector Connector Electrical characteristics SASE17 SASE36 Frequency_Out J6 J7 J8 J6 J7 J8 BNC Female J9
8. a trap message to a destination O SF Ee Gu RAG Om Synchronizing Critical Operations E Configuration E Status Tools SNMP RO Community public Community name ex public SNMP RY Community J private Community name ex private The above values become effective after a reboot Save configuration Traps Setup Traps destination 1 j 10 8 1 12 _IP address ex 192 168 0 101 Traps destination 2 IP address ex 192 168 0 102 Traps Community public Trap community ex public Global traps enable Yes y Channel A Frequency Input Fault Channel A 1PPS Input Fault Channel A TOD Input Fault No dl Channel A Input Fault Channel B Frequency Input Fault Channel B 1PPS Input Fault Channel B TOD Input Fault Save configuration Designed by SPECTRACOM a trademark of the OROLIA group download MIB 4 10 User s Manual Spectracom Corporation EPSILON Switch amp Amplifier System E SNMP RO community Community name for Read Only OIDs N SNMP RW community Community name for Read Write OIDs Traps destination 1 Primary SNMP manager address where traps are sent IB Traps destination 2 Secondary SNMP manager address where traps are sent al Traps Community SNMP code word that helps in filtering the traps and identifying the managed equipment family public by default 6 Global traps enable If Yes traps are sent according to individual enabling if No no traps are sent 7 Chan
9. assignment or fixed IP address Protocol Transfer Control Protocol and Internet protocol TCP IP Web page server with HTTP protocol for configuration status included Configuration and status are manageable through SNMP protocol The MIB includes a sub set of configuration and status parameters SNMP traps are sent to the network on event trigger 2 8 Operating Environment Operating temperature 5 to 60 C Storage temperature 40 to 85 C Relative humidity 95 non condensing Electromagnetic compatibility in accordance with EN61000 EN55022 EN60950 2 9 EMC Complies with the requirements of the standards e EN 61000 6 2 ed 2005 e EN 61000 6 3 ed 2007 e EN55022 ed 2006 Class B User s Manual 2 5 EPSILON Switch amp Amplifier System E 2 6 Spectracom Corporation User s Manual Spectracom Corporation EPSILON Switch amp Amplifier System E 3 Installation The unit can be used by itself or mounted in a rack Leave free space of a few centimeters under the unit in order to facilitate natural air flow from the bottom to the top of the SAS E e Connecting cables for signals and power supply should be secured to locks provided for this purpose e Connect a ground lead from the Earth pin on the SASOE back panel to the frame of the rack 3 1 Powering Up The SAS E can be powered from an AC source from a DC source or from both For full redundancy connect the DC power cables to the VDC connector and
10. the AC power cable to the AC connector Check the polarity of the power signal before connecting it refer to DC Power Supply and to the back panel labels for the pin out Priority is given to AC input Power up is immediate when connecting DC power with the cable while AC power must be switched on During power up check the initialization sequence process OS boot on the front panel All of the LEDs should be activated This process may take about two minutes 3 2 Network Connection The factory IP address is 192 168 0 100 in static mode On the back panel a reset button allows the user to return to this IP address by default Press the RST reset button and hold it for 2 seconds The ETH LED will blink during this process Connect the remote PC through a crossover Ethernet cable or through a network hub Set the PC IP address to an address belonging to the same sub network e g 192 168 0 001 Press the RST button and hold it for 2 seconds The ETH LED will blink during this process and after roughly 5 seconds the SAS E will restart Wait two minutes On the PC open a web browser page to http 192 168 0 100 Click to enter the web interface Go to the System Setup gt Network Setup web page Type in the password the factory default is pwd Modify the mode of IP address allocation static or DHCP and static address as necessary If the SAS E is already DHCP configured and if no DHCP server is available you cannot co
11. the internet port d Forced B Channel B forced in manual mode either through the front panel switch or through the internet port 6 Channel selection source Status of the source selection a Network The front panel switch is locked and the selection mode is made via the Ethernet port b Front panel The front panel switch is unlocked and the choice of the channel is made via the front panel switch Output Channel Status of all Outputs 1 Frequency output a OK Green Frequency inputs are monitored and all frequency outputs are OK b Alarm Red Frequency inputs are monitored and at least one frequency output is failed c Disable gray Frequency inputs and outputs are not monitored 2 ToD output a OK Green ToD inputs are monitored and all ToD outputs are OK b Alarm Red ToD inputs are monitored and at least one ToD output is failed c Disable gray ToD inputs and outputs are not monitored 3 1PPS output a OK Green 1PPS inputs are monitored and all 1PPS outputs are OK b Alarm Red 1PPS inputs are monitored and at least one 1PPS output is failed c Disable gray 1PPS inputs and outputs are not monitored User s Manual 4 5 EPSILON Switch amp Amplifier System E Spectracom Corporation Power Supply Status of both power supply 1 AC Alarms Status of Alarm 1 Urgent a b OK Green AC power is monitored and on Alarm Red AC power is monitored and off Disable Gray AC po
12. version b 16 x frequency outputs 16 x 1PPS outputs 2 x ToD outputs 2 x external signals Input Channel Status of all inouts for each channel 1 Frequency input a OK Green Frequency inputs are monitored and are present b Alarm Red Frequency inputs are monitored and are detected as failed c Disable Gray Frequency inputs are not monitored 2 TOD input b OK Green ToD inputs are monitored and are present b Alarm Red ToD inputs are monitored and are detected as failed c Disable Gray ToD inputs are not monitored 3 1PPS input a OK Green 1PPS inputs are monitored and are present b Alarm Red 1PPS inputs are monitored and are detected as failed c Disable gray 1PPS inputs are not monitored 4 Alarm input a OK Green Alarm inputs are monitored and there are no alarms on the input b Alarm Red Alarm inputs are monitored and the alarm input is in alarm c Disable Gray Alarm inputs are not supervised 5 Selected channel Status of the channel selected a Automatic A Channel A selected with the automatic mode either through the front panel switch or through the internet port 4 4 User s Manual Spectracom Corporation EPSILON Switch amp Amplifier System E b Automatic B Channel B selected with the automatic mode either through the front panel switch or through the internet port c Forced A Channel A forced in manual mode either through the front panel switch or through
13. EPSILON SWITCH amp AMPLIFIER SYSTEM E SAS17E SAS36E USER S MANUAL 95 Methodist Hill Drive Rochester NY 14623 Phone US 1 585 321 5800 Fax US 1 585 321 5219 3 Avenue du Canada 91974 Les Ulis France Phone 33 0 1 64 53 39 80 Fax 33 0 1 64 53 39 81 www spectracomcorp com www spectracom fr Ref Number 170024 D1 Manual Revision D1 08 September 2008 Copyright 2008 Spectracom Corporation The contents of this publication may not be reproduced in any form without the written permission of Spectracom Corporation Specifications subject to change or improvement without notice Spectracom EPSILON CLOCK NetClock Ageless TimeGuard TimeBurst TimeTap LineTap MultiTap VersaTap and Legally Traceable Time are Spectracom registered trademarks All other products are identified by trademarks of their respective companies or organizations All rights reserved SPECTRACOM LIMITED WARRANTY LIMITED WARRANTY Spectracom warrants each new product manufactured and sold by it to be free from defects in software material workmanship and construction except for batteries fuses or other material normally consumed in operation that may be contained therein AND AS NOTED BELOW for five years after shipment to the original purchaser which period is referred to as the warranty period This warranty shall not apply if the product is used contrary to the instructions in its manual or is otherwise subjected to mis
14. Pin Signal Description 1 Urg_al_ closed Urgent Alarm active closed contact 2 Urg_al_ closed Urgent Alarm active closed contact 3 Urg_al_ open Urgent Alarm active open contact 4 Urg_al_ open Urgent Alarm active open contact Characteristics Relay contact Pin 1 and 2 closed in case of urgent alarm active Pin3and 4 open incase of urgent alarm active Resistive contact Rating 30VA 250V 2 6 Non Urgent Alarm Connector Universal Serial Bus USB connector A series NURG Pin Signal Description 1 Nurg_al_ closed Non Urgent Alarm active closed contact 2 Nurg_al_ closed Non Urgent Alarm active closed contact 3 Nurg _al_ open Non Urgent Alarm active open contact 4 Nurg _al_ open Non Urgent Alarm active open contact Characteristics Relay contact Pin 1 and 2 closed in case of urgent alarm active Pin 3 and 4 opened in case of urgent alarm active Resistive contact Rating 30VA 250V 2 4 User s Manual Spectracom Corporation EPSILON Switch amp Amplifier System E 2 7 Ethernet Port Connector RJ45 Eth Pin Signal Description 1 TX Transmission signal plus 2 TX Transmission signal minus 3 RX Reception signal plus 4 5 6 RX Reception signal minus 7 8 Characteristics Interface 10 Base T 100 BASE T IEEE 802 3 compliant Full featured auto negotiation function IP address assignment DHCP automatic
15. always on The selection of the channel A or B depends on the results of the monitoring process The following table gives the source selection versus fault detection Channel Channel Selected Non Urgent Urgent A B Channel Alarm Alarm NOK NOK No change Active Active OK NOK A Active Non active NOK OK B Active Non active OK OK No change Active Active No change Same channel as in the previous state Those 3 modes can be selected with o Field 8 Network channel selection which allows the user to force the SAS E mode through the Ethernet port o Field 9 Front panel switch which allows the user to enable or disable the front panel switch o The front panel switch when it is enabled through the Ethernet port User s Manual 3 3 EPSILON Switch amp Amplifier System E Spectracom Corporation It is possible to enable or disable the front panel switch via the Ethernet port When disable the front panel switch has no action on the selection mode and this one could be only changed via the field network channel selection or via the embedded SNMP network channel selection command When the front panel switch is enabled the field Network channel selection has no action on the selection mode When the front panel switch is enables to set the SAS E in the mode o Forced A press and hold the key A for more than 2 seconds o Forced B press and hold the ke
16. ark of the OROLIA group The uploaded release is shown in the Application Version field The actual version is the running version Clicking on the Install New version button will result in an automatic restart of the SAS E The Delete File option is not used User s Manual 4 17 EPSILON Switch amp Amplifier System E Spectracom Corporation 4 1 8 4 Reboot This page allows the operator to perform a software or hardware reset This page is accessible with the user s password D S P E C T R A C M Synchronizing Critical Operations guration Reboot Hardware Please confirm to reboot the SAS E Yes Designed by SPECTRACOM a trademark of the OROLIA group Reset type Software Reset only the Ethernet port including Web server and SNMP server This reset has no effect on the signals selection and distribution Hardware Reset the SAS E This reset affects the signals selection and distribution 4 18 User s Manual Spectracom Corporation EPSILON Switch amp Amplifier System E 5 SNMP Control 5 1 MIB Content The MIB is made of elements related to Status Setup For full User s Configuration parameters that can be read GET procedure and written SET procedure Status information similar to the status displayed on page web that can be read GET procedure Selected channel Get Channel source selection Get Urgent alarm status Get Trap No urgent ala
17. cks are connected the SAS E offers a powerful redundant function by selecting automatically the better source This automatic selection may be by passed by the user to allow maintenance or for single clock operation In all cases the distributed signals Frequency 1 Pulse Per Second PPS Time of Day ToD are issued from the same source clock In automatic mode when the current selected source is detected faulty the SAS E switches all the distributed signals to the other source An Ethernet port allows managing and controlling the SAS E through embedded SNMP protocol and or web server The SAS E is available in two heights to adapt the output capacity to the user s requirements SAS17E 1u High Version 8 x frequency outputs 8 x 1PPS outputs 2 x ToD outputs 2 x external signals SAS36E 2u High Version 16 x frequency outputs 16 x 1PPS outputs 2 x ToD outputs 2 x external signals User s Manual 1 1 EPSILON Switch amp Amplifier System E Spectracom Corporation 1 1 Terminology DHCP Dynamic Host Configuration Protocol IP Internet Protocol MIB Management Information Base NTP Network Time Protocol OID Objet IDentifier PPS Pulse Per Second SAS Switch amp Amplifier System SNMP Single Network Management Protocol ToD Serial message Time of Day USB Universal Serial Bus 1 2 Inventory Before installing your Spectracom product please verify that all material ordered has been received If there is a di
18. d If equipment is returned without first contacting the support department and no problems are found during the repair work an evaluation fee may be charged EXCEPT FOR THE LIMITED WARRANTY STATED ABOVE SPECTRACOM DISCLAIMS ALL WARRANTIES OF ANY KIND WITH REGARD TO SPECTRACOM PRODUCTS OR OTHER MATERIALS PROVIDED BY SPECTRACOM INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Spectracom shall have no liability or responsibility to the original customer or any other party with respect to any liability loss or damage caused directly or indirectly by any Spectracom product material or software sold or provided by Spectracom replacement parts or units or services provided including but not limited to any interruption of service excess charges resulting from malfunctions of hardware or software loss of business or anticipatory profits resulting from the use or operation of the Spectracom product or software whatsoever or howsoever caused In no event shall Spectracom be liable for any direct indirect special or consequential damages whether the claims are grounded in contract tort including negligence or strict liability EXTENDED WARRANTY COVERAGE Extended warranties can be purchased for additional periods beyond the standard five year warranty for those products covered under five year warranty Contact Spectracom no later than the last year of the standard five y
19. disabled The default of the channel loss of one monitored signal generates an Urgent alarm The SAS E does not switch on the other channel The front panel switch is locked 3 2 User s Manual Spectracom Corporation EPSILON Switch amp Amplifier System E When this field in on A and B the SAS E monitors both channels and the channel selection A or B depends on o The results of the signal monitoring process according the choices on fields 2 to 5 o The programming of field 8 Network channel selection and field 9 front panel o The front panel switch In this configuration the SAS E has 3 modes o Forced A When this mode is selected the LED AUTO in the front panel is always off and the LED A is on This mode forces the selected channel A whatever the results of the signal monitoring process In the case of a channel A default the Urgent Alarm is active and in the case of a channel B default the Non Urgent Alarm is active o Forced B When this mode is selected the LED AUTO in the front panel is always off and the LED B is on This mode forces the selected channel B whatever the results of the signal monitoring process In the case of a channel B default the Urgent Alarm is active and in the case of a channel A default the Non Urgent Alarm is active o Automatic When this mode is selected the LED AUTO in the front panel is
20. ear warranty for extended coverage www spectracomcorp com www spectracom fr Spectracom Corporation EPSILON Switch amp Amplifier System E iil User s Manual EPSILON Switch amp Amplifier System E Spectracom Corporation Table of Contents NNNOORWODM NA dodo N Nh D Da nm E amp D D DD D 0 Y O O1 PRPRRARRARAWWOWWWWW Sh ok ob eee O O1 Be A NO O1 amp amp D 4 1 8 5 1 5 2 6 1 INTRODUCTION e RAS Er den ik et rach enr n Re ts 1 1 Termino ds as 1 2 o et Sat se eS a a ea nn 1 2 INS POCION cis dt a en A CR a S 1 2 SAS 17 E OOO as 1 3 SASI0E SVMODUG ina as 1 4 Dimensions and Wet OS 1 5 Front andiR ar Panel csi 1 7 SASI 7E a eR Ru nt es ere me eee re 1 7 SAODIDE AN a 1 8 EEATURES sans a ont A 2 1 Main Power SUPpINSnr A R 2 1 B ROWET S ppl yeni enes ee Re Ne 2 1 A Se er ne er creer es 2 2 O tp t Signal Saca AS 2 3 E rte Roar ee ale en alles ei Oe tetas 2 4 Preis Urgent Ala oia 2 4 Ethernet POM tun A Reine 2 5 Operating ENVIO MEN asia ss 2 5 EM O O A an cy pai alee 2 5 INSTALLATION 0 iS A A a mo sia ante 3 1 Powering UN capas a ir doch hla 3 1 Network Connection ic ta 3 1 Configuring and Operating the SAS E 3 2 Status Ol the SAGE ae la 3 4 Salus ED E O en eee ae eee eee ee 3 4 A cake Nues 3 5 Powering DOWN 3 6 WEG INTERFACE 023 A Oak RAR dees 4 1 WED PAG SS eset dt AA 4 1 Welcome ACG oh asco o Sa 4 1 Upper Task Bar and Page Header cooo
21. essible with the user s password Manual Setup time must be set on every switch on There are two ways to set up the time o Automatically by addressing an NTP server o Manually by setting date and time User s Manual 4 13 EPSILON Switch amp Amplifier System E Spectracom Corporation D SPECTRAC OM Synchronizing Critical Operations Configuration Tools Time Setup NTP Parameters Use NTP Server Enabled y Select if you want to update system time with NTP server NTP server address I 172 16 207 166 NTP server IP address ex 192 168 0 101 Request frequency 30 NTP request frequency second Save configuration Time Parameters 25 z 01 gt 2008 14715 14 7 00 Manual Time Set Manual Time Adjust 15 15 Designed by SPECTRACOM a trademark of the OROLIA group 1 NTP Parameters a Use NTP Server i ENABLE An NTP server is available on the network The System time is updated automatically on every Request frequency ii DISABLE No NTP server is available on network The system time must be updated manually according to the fields for Time Parameters b NTP server Address IP address of the NTP server in the network c Request frequency Number of seconds between each request 2 Time Parameters a Date Time and Set button Time manual setting when the field Use NTP Server is disabled b Manual Time Adjust Adjust the time by 1 second when the field
22. he system time in order to date the log event protected by password 3 SAS E Status Summary of status and alarms of SAS E 4 Tools a Event logging Display of event history b Software Version Display of current version of software parts c Software upgrade Upgrading software d Reboot Hardware or software reset Header time information Provided by the SAS E 4 2 User s Manual Spectracom Corporation EPSILON Switch amp Amplifier System E 4 1 3 SAS E Status This page contains a copy of the SAS E front panel with all the monitored states inputs outputs power supply alarms and the equipment type This page is automatically refreshed every 15 seconds D S RIE e TRA O M Synchronizing Critical Operations configuration SAS E Status Equipment type SAS36 Input Channel Channel A Channel B Frequency input TOD input Disabled Disabled 1PPS input Ei aaa Alarm input Disabled Disabled Selected channel Automatic B Channel selection source Front Panel Output Channel Frequency output E A TOD output Disabled 1PPS output Urgent No Urgent Designed by SPECTRACOM a trademark ofthe OROLIA group User s Manual 4 3 EPSILON Switch amp Amplifier System E Spectracom Corporation Equipment type 1 SAS17E a 1 U high version b 8x frequency outputs 8 x 1PPS outputs 2 x ToD outputs 2 x external signals 2 SAS36E a 2U high
23. hernet gt Supply amp distribution lt gt Monitoring gt port x2 v 8xFreq 8x1 pps 2xToD Ext Sig Alarm Alarm urg non urg 1 3 User s Manual EPSILON Switch amp Amplifier System E Spectracom Corporation 1 5 SAS36E Synoptic GPS antenna GPS antenna 4 z External Clock External Clock A source B source E E F il rilal f Fl 1 Tl alt r P O 1 S x2 r P O l S x2 el P DI i e P D ae q s I q s I m 8 m 8 Al A A A A B B B B B So Switch VV VV Y VV Y Y Y and Source selection amp switching Amplifier Poe EF I T E System r Pol x p D t x2 q S S 1 Vac Redundant 8 Power Men Vdc Output amplification Signal Ethernet gt Supply amp distribution lt gt Monitoring port x2 M 16x Freq 16X1pps 2xToD Ext Sig Alarm Alarm urg non urg User s Manual Spectracom Corporation EPSILON Switch amp Amplifier System E 1 6 Dimensions and Weight SAS17E SAS36E 1u version 2u version Height 43 6 mm 0 1mm 88 1 mm 0 1mm Width 483 mm 0 1mm 483 mm 0 1mm Depth 323 mm 0 1mm 323 mm 0 1mm Weight 3 2 kg 4 1 kg 1 5 User s Manual EPSILON Switch amp Amplifier System E Spectracom Corporation 1 6 User s Manual Spectracom Corporation EPSILON Switch amp Amplifier System E 1 7 Front and Rear Panel 1 7 1 SAS17E SPECTRACOM SYNCHRONIZING CRITICAL OPERATIONS
24. nel A Frequency Input Fault a Yes Generates a trap when the frequency signal input on channel A fails b No No trap generated 8 Channel A 1PPS Input Fault a Yes Generates a trap when the 1PPS signal input on channel A fails and is monitored b No No trap generated 9 Channel A TOD Input Fault a Yes Generates a trap when the ToD signal input on channel A fails and is monitored b No No trap generated 10 Channel A Input Fault a Yes Generates a trap when an alarm input on channel A becomes active and is monitored b No No trap generated 11 Channel B Frequency Input Fault a Yes Generates a trap when the frequency signal input on channel B fails b No No trap generated 12 Channel B 1PPS Input Fault a Yes Generates a trap when the 1PPS signal input on channel B fails and is monitored b No No trap generated 13 Channel B TOD Input Fault a Yes Generates a trap when the ToD signal input on channel B fails and is monitored b No No trap generated 14 Channel B Input Fault a Yes Generates a trap when an alarm input on channel B becomes active and is monitored b No No trap generated User s Manual 4 11 EPSILON Switch amp Amplifier System E Spectracom Corporation 15 Frequency Output Fault a Yes Generates a trap when one of the output frequency signals fails and frequency inputs are monitored b No No trap generated 16 1PPS Output Fault a Yes Generates a trap when one of the output 1PPS
25. nnect a PC to access the SAS E network configuration pages You may use the reset button on the back panel to reset the IP address in this case User s Manual 3 1 EPSILON Switch amp Amplifier System E Spectracom Corporation 3 3 Configuring and Operating the SAS E The SAS E must be configured through an Ethernet network with a web browser After the boot sequence open a browser to the SAS E IP address http 192 168 0 100 Go to SAS E Configuration gt SAS E Setup and program the setup parameters as follows D SPECIRACOM Synchronizing Critical Operations Configuration Status Tools SAS E Setup entre Channel L AsndB Y 1 Frequency Signal Enabled M 2 1PPS Signal Enabled 3 TOD Signal a ETIE 4 Alarm Signal Disabled a 5 AC Presence Enabled 6 DC Presence Enabled 7 SS Network channel selection Automatic 8 Front panel switch Enabled 9 Save configuration For both channels the fields 2 to 5 allow the user to set up the signal monitoring process Each input of the SAS E Frequency 1 PPS ToD and Alarm can be monitored individually with the Enable or Disable selections The channel is considered OK when all monitored signals are connected and present The field 1 Channel allows the user to monitor the channel inputs When this field is on only A or only B the SAS E forces the selected channel whatever the results of the over channel The switching function is
26. ononcccccnonnconocccccononanoncncnonnnanannnnnnnnnnnannnnos 4 2 SASE A E 4 3 Admin Password PA it AA 4 7 Network Setup Page tua ris 4 8 SNMP and Traps Setup Page vana 4 10 SAS E Configuratio Meena ara aaa ee ane Rs aE 4 13 TOONS dered tnt ade AS 4 15 SNMP CONTROL SAME so Se st ro ere 5 1 NIB GONG nh aid 5 1 SNMP Traps ten tens Goi rad 5 2 MAINTENANCE att tota 6 1 Updating the Software Version ici eee ee 6 1 User s Manual Spectracom Corporation EPSILON Switch amp Amplifier System E x User s Manual Spectracom Corporation EPSILON Switch amp Amplifier System E Introduction This document is the User s Manual for the EPSILON Switch and Amplifier System E17 and the EPSILON Switch and Amplifier System E36 Unless otherwise indicated details contained herein apply to both models The SAS E achieves redundant Time amp Frequency source monitoring with intelligent and automatic switching It amplifies signals from the selected source and offers a large quantity of output channels The SAS E receives and monitors continuously signals from 1 or 2 external clocks Frequency sine wave signal from 1 MHz up to 16 MHz 1 pulse per second time synchronization TTL 50Q Time Of Day message RS232C serial line External signals External clock status relay contact Monitoring results lost signal and minimal period detection are reported to the user through dedicated LEDs and through an Ethernet port When 2 external clo
27. r A 18 02 08 Creation 23 04 08 Update marketing of 1PPS and frequency inputs B l update IP fix address C nee First iteration of this Spectracom documentation converted from Temex Sync documentation DO 25 08 08 Update Web page SNMP and Traps setup page D1 08 09 08 Update rear panel Spectracom Corporation 95 Methodist Hill Drive 3 Avenue du Canada Rochester NY 14623 91974 Les Ulis France www spectracomcorp com www spectracom fr Phone US 1 585 321 5800 Phone 33 0 1 64 53 39 80 Fax US 1 585 321 5219 Fax 33 0 1 64 53 39 81
28. rm status Get Trap Frequency input channel A status Get Trap PPS input channel A status Get Trap TOD input channel A status Get Trap Alarm input channel A status Get Trap Frequency input channel B status Get Trap PPS input channel B status Get Trap TOD input channel B status Get Trap Alarm input channel B status Get Trap Frequency output status Get Trap PPS output status Get Trap TOD output status Get Trap AC Power status Get DC Power status Get Network channel selection Set Get Front panel switch Set Get MIB copy content access use the download MIB button on the trap setup page Manual 5 1 EPSILON Switch amp Amplifier System E Spectracom Corporation 5 2 SNMP Traps Traps are based on status information readable by GET procedure refer to the preceding lists Traps are generated on events related to alarm and configuration modifications The two trap destinations are programmable and traps are individually enabled in the trap setup web page 5 2 User s Manual Spectracom Corporation EPSILON Switch amp Amplifier System E 6 Maintenance The SAS E is fully automatic and requires no field maintenance 2 Fuses 5 x 20 1A TD 250V 6 1 Updating the Software Version Refer to the corresponding webpages to perform the software firmware upgrade User s Manual 6 1 REVISION HISTORY Revision ECN Description Level Numbe
29. screpancy please contact Spectracom Customer Service Customer service is available by telephone at 33 0 1 64 53 39 80 France or 1 585 321 5800 United States Updated contacts information are available on web site see Support page CAUTION Electronic equipment is sensitive to Electrostatic Discharge ESD Observe all applicable ESD precautions and safeguards when handling the Spectracom equipment NOTE lf equipment is returned to Spectracom it must be shipped in its original packing material Save all packaging material for this purpose 1 3 Inspection Unpack the equipment and inspect it for damage If any equipment has been damaged in transit please contact Spectracom Customer Service Customer service is available by telephone at 33 0 1 64 53 39 80 France or 1 585 321 5800 United States Updated contacts information are available on web site see Support page 1 2 User s Manual Spectracom Corporation EPSILON Switch amp Amplifier System E 1 4 SASI 7E Synoptic GPS antenna GPS antenna External Clock External Clock A source B source x2 x2 gt Con gt vo gt Gor waon W aooe w Jows Wears Pp W dam mx En Switch VV V Y Y VV VV Vv and Source selection amp switching Amplifier alae ae System r o x q S p S x 1 Vac gt Redundant Power ae Vd Output amplification Signal Et
30. signals fails and 1PPS inputs are monitored b No No trap generated 17 TOD Output Fault a Yes Generates a trap when one of the output ToD signals fails and ToD inputs are monitored b No No trap generated 18 Channel Swap a Yes Generates a trap when the SAS E swaps from channel A to channel B or from channel B to channel A b No No trap generated 19 Power Fault a Yes Generates a trap when any enabled power source alarm is detected b No No trap generated 20 Urgent Alarm a Yes Generates a trap when an Urgent alarm is generated b No No trap generated 21 No Urgent Alarm a Yes Generates a trap when a No Urgent alarm is generated b No No trap generated 22 Download MIB Link for downloading zipped MIB text file 4 12 User s Manual Spectracom Corporation EPSILON Switch amp Amplifier System E 4 1 7 SAS E Configuration 4 1 7 1 SAS E Setup D SPECTRACOM Synchronizing Critical Operations SAS E Setup Channel Aans zl Frequency Signal Enabled y Enabled 1PPS Signal Enabled y TOD Signal Enabled y Alarm Signal Disabled J AC Presence Enabled a DC Presence Enabled Channel Selection Network channel selection I Automatic z Front panel switch Disabled z Save configuration Designed by SPECTRACOM a trademark of the OROLIA group 4 1 7 2 Time Setup This page allows the operator to configure the SAS E system time in order to date the log events lt is acc
31. tch to the 0 position and or unplug the DC power supply 3 6 User s Manual Spectracom Corporation EPSILON Switch amp Amplifier System E 4 Web Interface When connecting to the SAS E IP address with a web browser HTTP protocol the user can check the SAS E status modify setup parameters and perform software updates The status web pages may be accessed by the user at any time Setup pages require a password the factory default is pwd The protocol used for accessing the SAS E is HTTP 4 1 Web Pages 4 1 1 Welcome Page D SPEC LRA COM Synchronizing Critical Operations WELCOME TO SAS E INTERFACE Click to enter Spectracom 3 Avenue du Canada 91974 Les Ulis Cedex France Tel 33 0 1 64 53 39 80 Fax 33 0 1 64 53 39 81 Email sales spectracom fr Web www spectracom fr Click to enter the web site The first displayed page is the STATUS page User s Manual 4 1 EPSILON Switch amp Amplifier System E Spectracom Corporation 4 1 2 Upper Task Bar and Page Header D S PE TRA 5 O M Synchronizing Critical Operations Tools Gives access to one of the following menus 1 System Setup a Network setup Network connection parameters protected by a password b SNMP and Traps setup SNMP parameters and traps enable protected by password c Logout Log out from the web site 2 SAS E configuration a SAS E setup Configure the equipment protected by password b Time setup Configure t
32. use abnormal operations accident lightning or transient surge repairs or modifications not performed by Spectracom The GPS receiver is warranted for one year from date of shipment and subject to the exceptions listed above The power adapter if supplied is warranted for one year from date of shipment and subject to the exceptions listed above THE TIMEVIEW ANALOG CLOCKS ARE WARRANTED FOR ONE YEAR FROM DATE OF SHIPMENT AND SUBJECT TO THE EXCEPTIONS LISTED ABOVE THE TIMECODE READER GENERATORS ARE WARRANTED FOR ONE YEAR FROM DATE OF SHIPMENT AND SUBJECT TO THE EXCEPTIONS LISTED ABOVE THE WIRELESS CLOCK SYSTEM TRANSMITTERS AND OR TRANSCEIVERS AND CLOCKS ARE WARRANTED FOR TWO YEARS FROM DATE OF SHIPMENT AND SUBJECT TO THE EXCEPTIONS LISTED ABOVE THE EPSILON CLOCKS BOARDS AND SYNCHRONIZATION UNITS ARE WARRANTED FOR TWO YEARS FROM DATE OF SHIPMENT AND SUBJECT TO THE EXCEPTIONS LISTED ABOVE The Rubidium oscillator if supplied is warranted for two years from date of shipment and subject to the exceptions listed above All other items and pieces of equipment not specified above including the antenna unit antenna surge suppressor and antenna pre amplifier are warranted for 5 years subject to the exceptions listed above WARRANTY CLAIMS Spectracom s obligation under this warranty is limited to in factory service and repair at Spectracom s option of the product or the component thereof which is found to be defecti
33. ve If in Spectracom s judgment the defective condition in a Spectracom product is for a cause listed above for which Spectracom is not responsible Spectracom will make the repairs or replacement of components and charge its then current price which buyer agrees to pay Spectracom shall not have any warranty obligations if the procedure for warranty claims is not followed Users must notify Spectracom of the claim with full information as to the claimed defect Spectracom products shall not be returned unless a return authorization number is issued by Spectracom Spectracom products must be returned with the description of the claimed defect and identification of the individual to be contacted if additional information is needed Spectracom products must be returned properly packed with transportation charges prepaid Shipping expense Expenses incurred for shipping Spectracom products to and from Spectracom including international customs fees shall be paid for by the customer with the following exception For customers located within the United States any product repaired by Spectracom under a warranty repair will be shipped back to the customer at Spectracom s expense unless special faster delivery is requested by customer Spectracom highly recommends that prior to returning equipment for service work our technical support department be contacted to provide trouble shooting assistance while the equipment is still installe
34. wer is not monitored OK Green DC power is monitored and on Alarm Red DC power is monitored and off Disable Gray DC Power is not monitored OK Green No urgent alarm present Alarm Red An urgent alarm is present which means that there is at least one fault on one of the outputs monitored 2 No Urgent a b OK Green No urgent alarm present Alarm Red A non urgent alarm is present which means that there is only one channel detected on fault or there is a fault in one power supply User s Manual Spectracom Corporation EPSILON Switch amp Amplifier System E 4 1 4 Admin Password Page A password is necessary to access the Setup pages The default password is pwd It can be modified in the Network Setup page D SPECTRA COM Synchronizing Critical Operations Tools SAS E Setup A login is needed to display this page Click to login Designed by SPECTRACOM a trademark of the OROLIA group User s Manual 4 7 EPSILON Switch amp Amplifier System E Spectracom Corporation 4 1 5 Network Setup Page This page allows the user to modify the Network connection parameters D S PE 2 TR A C M Synchronizing Critical Operations IP Address 1721620712 Sub network mask 2552552550 Sub network address 172162070 Broadcast address 17216207 255 Broadcast address ex 192 168 0 255 Default Gateway 172 16 207 1 Default Gateway ex 192 168 0 1 Change password mal Save configuration
35. y B for more than 2 seconds o Automatic press and hold the key auto for more than 2 seconds According to the available power sources enable or disable the Power Alarms using the AC Presence and DC Presence fields A default on a supervised power generates a Non Urgent Alarm All parameters are saved in a flash EPROM and are reloaded on further reboot In the case of a reboot and when the panel switch is enabled while Channel A and B are monitored the selection mode is set in the automatic mode by default 3 4 Status of the SAS E The status of SAS E could be shown by a specific web page refer to the web page discussion contained herein or by the status LED on the front panel 3 4 1 Status LED There are 4 green status LED for each source AL Result of alarm input monitoring F Result of frequency monitoring 1PPS Result of 1PPS monitoring ToD Result of ToD monitoring LEDs are ON when signal is monitored and present If the signal is absent or not monitored the corresponding LED is off There are 3 orange status LEDs for the source selected A ON when the channel A is selected and used to supply the signal outputs B ON when the channel B is selected and used to supply the signal outputs Auto ON when the automatic mode is selected through the front panel or the Ethernet port and OFF when the SAS E is forced on a specific channel 3 4 User s Manual Spectracom Corporation EPSILON Switch amp
Download Pdf Manuals
Related Search
Related Contents
Fluke Digital Multimeter 80 Series V User's Manual Sikafloor®-156 - Distribuciones Villamar User Manual CableWholesale RJ-11, 14ft VT1521 - VTI Instruments Samsung Sistema Micro HiFi E330 User Manual 1 - hifi-advice.com Junkers-Ceramini-ZSN-11-7-KE-Installation-und T'nB Bubble Pompe Doseuse Serie “ FMS” Copyright © All rights reserved.