Home

USER`S MANUAL/PARTS LIST

image

Contents

1. Hexagon Socket Head Cap Screw M3 8 120030802TN Cord Presser No 2 S 0L1130280S10 For Looping Guide Stopper S 0L1130190S00 Stopper Guide 15 Needle S 0L1130210S00 Hexagon Socket Head Cap Screw M4 5 120040502TN Plain Washer M4 10 t0 8 S301041002SC Ball Plunger BST4 615400020000 Hexagon Nut Type 1 M4 S210040001SC Stopper Collar 6mm Dia 502106010000 Shaft Stopper 0L1130200000 Screw with Pin No 5 1 8 2 5 513550010000 O ring S 5 612200100000 Thread Course Cord 0L1130300000 Thread Guide No 2 516202020000 Truss Head Screw 9 64 6 SA30740601CL Cord Guide 0L1130010000 Truss Head Screw 9 64 4 SA30740401CL Needle Clamp Cording Device S 0L1130330S00 Needle Clamp Cording Device 15 Needle S 0L1130150S00 Guide Base C EK0341000000 No pre processing on Needle Bar Case Bracket Spacer C EK0342000000 No pre processing on Needle Bar Case Truss Head Screw 9 64 40 5 SA30740501CL Note As for parts with marks or please follow our instructions on Table of Contents in your parts order IA10 BOBBIN NEEDLE BAR CASE Ss LS ZO 9 J ZR FCs a A 5 Eo og So a 2 GC07 a 5 CORDING DEVICE MAIN BODY Description Part No EK 2 Remark Bo
2. un 0elansnk sans arten ns nern 6 6 erg ht adjusttient ern a ae E E E O 7 6 1 Height adjustment of cording ss 7 6 2 Height adjustment of looping ss 7 Switching of spec looping cording 1 Detiching of cover ner Rise se ten oe E E ese ee 8 2 Detaching of lower thread guide and cord release pin 8 3 Change detaching of presser foot nnrinn atannitirnnninein lien 9 In case of standard type presser foot 321 Detaching Of top COVET u a ine etienne ete tienne 9 3 2 Detaching of presser foot 2a oi Bae i SR Ar Tan Re 10 3 3 Attaching of cord release pin and needle 10 3 4 Adjustment of lower dead point 11 3 5 Adjustment of upper dead point position 12 3 6 Attaching of upper thread locking device 12 3 7 Attaching of tension base and top cover 13 In case of noise reduction type presser foot 3 8 Chang eof press r foot icc lens unie des ai rk mr 14 3 9 Attaching of upper thread locking device lower thread guide and cord release pin 14 A Switching Of SDEC sise stiegen lern Rn Re nr sit stade these 15 4 1 Detaching of cord presser C set 15 4 2 Attaching of cord presser A set 15 5 Adjustment of cord presser A set 16 6 Attaching of faceplates cette hci ren ae eh ee ie ent 17 Change of spec cording looping 1 D taching Of COVED ere at nen AGIA Ange Ra BER Race 18 2 Detaching of lower thread gu
3. gt Lower thread guide for KB 2M 14 IA10 Switching of spec looping cording 4 Switching of spec 4 1 Detaching of cord presser C set 1 Loosen the screw to remove the cord presser C set 2 Pull the clutch collar to the outside and loosen the set screw to remove the collar and spring SD coir 2 oe Set screw Spring Clutch collar 4 2 Attaching of cord presser A set 1 Attach the collar to the cord guide shaft and fix it using the screw temporarily 2 Pass the spring to the cord guide shaft and attach the cord presser A set to the cord guide shaft and fix it using the screw temporarily Cord presser A set differs depending on size of hole that passes cord Use proper one that fits thickness of cord to use MD ee D Set screw IA10 15 Switching of spec looping cording 5 Adjustment of cord presser A set 1 Put the shaft guide pin into the groove as shown in the illustration below Shaft guide pin 2 Turn the main shaft counterclockwise by hand to set it to the position of lower dead point refer to p 3 3 Loosen the screw and push down the needle bar by hand 4 After aligning the center of the hole of the cord presser A set with the tip of the needle tighten the screw When needle does not stick on cord during cording perform adjustment so that the cord feed hole comes nearer to the needle Cord
4. 3 2 Detaching of presser fodt nerunnennsnen sinn anna EE EE Ra 26 3 3 Attaching of cord release pin and needle 26 3 4 Adjustment of lower dead point 26 3 5 Adjustment of upper dead point position 26 3 6 Attaching of upper thread locking device 26 3 7 Attaching of tension base and top cover 26 In case of noise reduction type presser foot 3 8 Change of presser foot aan a RR ke 26 3 9 Attaching of upper thread locking device lower thread guide and cord release pin 26 4 Attaching of main body of cording device 27 4 1 Attaching of main body of cording device uenenensenseessensennsenseeneenneennnnne nennen nennen 27 4 2 Adjustment of cord presser A set 27 4 3 Attaching of cord guide sise 28 5 Attaching of bobbin bracket set nennen iii ERE 29 5 1 Model equipped with rotary type tension base 29 9 2 Other models teen hee inne RER eas 30 6 Attaching of face plates seeen aeee er oar Paea ar EE ARE r Be lebenden 30 When attaching device for the first time looping 1 Attaching of cord release pin ss 31 2 1 Attaching of main body of cording device u nennnsenseessensennsenneeneenneennnnne nennen enenennne 32 2 2 Adjustment of cord presser C set and fixing of guide base nnenneeeneeenennennnne 33 2 3 Attaching of cord guide sise den iini AEE EE E A E E EE 33 2 Setting of main body of cording device
5. Contents Main body of cording device EK 1 Bobbin and needle bar case EK 2 About marks and marks affixed to part numbers on the parts list The part whose part number has marks at lower four digits differs depending on model spec etc When you place an order of such a part please also inform us of your model embroidery space and machine number Example TFGN G1215 450 x 330 S No 01234 L J N y yY Model Embroidery space Machine number The part whose part number has marks at lower four digits differs depending on a number of needles When placing an order of part replace marks with numbers Example in case of EK012345 the last four digits are as follows 3 needle type 0300 6 needle type 0600 9 needle type Heer 0900 12 needle type 1200 15 needle type 1500 Regarding the part number that contains description of or the part differs depending on model spec etc When you place an order of such a part please also inform us of your model embroidery space and machine number 35 EK 1 CORDING DEVICE MAIN BODY RS QUES mm A SS OD Ver S Gs YR un Sn KCK No pre processing in Needle Bar Case IA10 CORDING DE
6. fins ieni an E EE E EE Meee 32 3 Attaching of bobbin bracket set ss 33 4 Attaching of face plate nee sem EEE EA E EE EAEE EE 33 When cording device is not used 1 Bobbin 2 2 3 Ne e ta Re A R N ec RR ee a ee 34 2 Clutch Collar aniren ee en a a a a o sen 34 3 Cord g ide shafto rrote 0er EO A EE PEE 34 Parts list IA10 Items to notice when using this device IA10 Items to notice when using this device when using cording device set setting on the machine side setting for cording device to To use When using cording device with setting Not to use trouble will occur at cording embroidery For how to set refer to the user s manual of the machine Or perform works described in this user s manual turn OFF the power switch If performing works with the power switch turned ON you could be injured by unexpected malfunctioning of the machine wnen using cording device in Looping spec setthe number of operating revolutions to 600 rpm at the maximum When using the cording device with the number of revolutions exceeding this it will be broken In addition main body of the machine such as presser foot could be broken LE When using cording device in Cording spec it is possible to use the device with the maximum number of revolutions rpm of the machine when cording device is not used keep the cord presser set moved up retracting position If you move the em
7. of main body of cording device 1 Fix the base and bracket spacer to the needle bar case using the screw 1 temporarily 2 How to attach the base differs depending on spec of needle bar case e When the machine has attaching hole for cording device fix the base and washer to the needle bar case using the screw 2 temporarily e When the machine has attaching hole for sequin device fix the base and collar to the needle bar case using the screw 2 temporarily e When the machine does not have attaching hole on the needle bar case fix the base C and spacer C to the needle bar case using the screw 3 and then fix the base to the base C using the screw 4 3 Fix the stopper guide set to the base using the screw 5 4 Fix the thread course to the stopper guide set using the screw 6 KB 2M Attaching hole exists Sequin device attaching hole exists Screw 2 Cw Screw 2 X COS Gy O NIJ Base m Screw 1 Thread course oy Screw 3 wy Stopper guide set Screw 1 32 IA10 When attaching device for the first time looping 2 2 Adjustment of cord presser C set and fixing of guide base 1 Put the shaft guide pin into the groove 2 Push the clutch collar so that the stopper touches upper face of the shaft To adjust height size of loop to be sewn refer to Height adjustment p 7 Shaft guide pin 3 Turn the main shaft counterclockwise by hand to set it to the position of lower d
8. MX series TFKN TLFD II TMLH II mixed type TCMX mixed type In case of standard type presser foot 3 1 Detaching of tension base and top cover Reference 7 Detaching of top cover P 9 3 2 Attaching of presser foot 1 Loosen the screws 1 and screw 2 to move up the needle bar 2 Pass the spring presser foot and cushion ring to the needle bar Needle bar a IR ti a Spring Screw 1 Presser foot IE Cushion ring amp Se 18 IA10 Change of spec cording looping 3 3 Attaching of cord release pin and needle 1 Pass the needle bar to the lower part of the framing of the needle bar case and fix the needle bar using the screw 1 temporarily 2 Attach the cushion ring cord release pin and needle to the needle bar and fix them using the screw 3 3 Loosen the screw that is fixed temporarily Needle bar al Le Screw 1 Needle Pay attention to the direction of the cord release pin IA10 19 Change of spec cording looping 3 4 Adjustment of lower dead point 1 Remove the needle plate and turn the main shaft counterclockwise to set it to the position of lower dead point refer to p 3 2 As shown in the illustration below align the notch part of smaller side of the lower dead point gauge with needle 3 Pus
9. USER S MANUAL PARTS LIST CORDING LOOPING DEVICE KB 2M O KB2M08 LE 2005 10 Foreword Foreword This manual is a guidebook for using the KB 2M correctly Assembling adjustment of the device and items to notice when using the device are described in this manual Please read this manual thoroughly and use the device after understanding the contents The contents of this manual are largely divided into the following sections Important safety instructions Preparation before using the device Switching of spec looping gt cording Change of spec cording looping When attaching device for the first time cording When attaching device for the first time looping When cording device is not used Parts list This manual may contain discrepancies in detailed information when compared with the actual product due to continued research and improvements If any question about the product or the contents of this manual arises please consult your TAJIMA distributor Please keep this manual near the machine for immediate reference Tokai Industrial Sewing Machine Co Ltd IA10 Important safety instructions Important safety instructions To use the device safely it is necessary to handle it correctly Please read the IMPORTANT SAFETY INSTRUCTIONS described in this manual thoroughly and do not handle this device until you fully understand the contents Since items to notice when handlin
10. VICE MAIN BODY Description Part No EK 1 Remark Base Cord Presser 0L1130240002 Spacer 3 8mm Dia 0L1130310011 For KB 2M Attaching Hole Collar No 1 4 2P 502542010000 For Sequin Device Attaching Hole Truss Head Screw 9 64 40 8 SA30740802CL For Washer Spacer Truss Head Screw M4 10 S130041001SD For Collar Bracket Spacer A EK0115A00000 1mm Thick Round Countersunk Head Screw 9 64 40 9 5 SA53740951CL For TEHX C TLFDII TMLH mixed type TFKN Countersunk Head Screw M4 10 S150041002SD For TEJT C TFGN series TFMX series TCMX mixed type Spacer 011130180000 For 15 Needle M C Guide Pipe Cord 011130290001 Truss Head Screw 9 64 6 SA30740601CL Truss Head Screw 9 64 40 10 SA30741001CL For 15 Needle M C OD CO NIAI Ju AK ululw NIT Guide Plate L EK0334010000 Guide Plate R EK0333010000 Flat Fillister Head Screw 1 8 44 5 SA41730501CN Thread Suspender Disk 0B0200050000 Compression Spring 0 3mm Dia 507603020000 Presser Thread Suspender Spring 0B0200060000 Stepped Screw No 1 9 64 7 5 512153060000 Cord Guide Shaft EK0336010000 Stopper Collar 7 24mm Dia 502101020000 Hexagon Socket Head Set Screw M3 3 170030301TN Compression Spring 0 5mm Dia 507605140000 Cord Presser No 1 1 1mm Dia S 0L1130091S02 For Cording
11. bbin Bracket KB2 ULA000000100 For TLFD Il Bobbin Bracket Rotary KB2 ULA100000100 For TFGN series TFMX series TEHX C TMLH mixed type TFKN Bracket No 1 Bobbin Holder 0L1130100000 For TLFD Il Bracket No 2 Bobbin Holder 0L1130140000 For TFGN series TFMX series TEHX C TMLH mixed type TFKN Hexagon Socket Head Cap Screw M4 25 S120042501TN Spring Washer M4 S402040001KC Plain Washer M4 10 t0 8 S301041002SC Base Bobbin Shaft Holder Large Size 0L1310060000 Oo Na URI ID Ie Pan Head Screw M3 10 S160031002SD Bracket Bobbin L 08068010L000 Stepped Screw No 1 M4 11 4 512104030000 Wave Washer M6 S305061051TN Plate Spring t0 5 507805010011 Cord Stopper Spring 507803110000 Pan Head Screw M3 3 S160030301MZ Bracket Bobbin R 08068010R000 Hexagon Socket Head Cap Screw M4 10 S120041002TN Washer with Teeth WSLO40000TPO Knurled Screw M4 10 511D04050000 Compression Spring 0 7mm Dia 507607140000 Plate Spring t0 3 507803040011 Pan Head Screw M2 3 S160020301MZ Screw with Pin No 5 M4 104 513504020011 Hexagon Nut Type 3 M4 S212040002SD Type 3 Bobbin Large Size 011310070000 Presser Foot Cording A 0L1130080A00 For TEHX C TLFD II TMLH mixed type TFKN Presser Foot Cording A 0L1130230A00 For TEJT C TFGN seri
12. broidery frame with the cord presser set lowered the cording device and the embroidery frame will be broken wnen using cording device embroidery space will be limited Before performing embroidery keep the cord presser set moved up retracting position to check if the cord presser set does not touch the embroidery frame by trace operation Cord presser set Ht Preparation before using the device Preparation before using the device 1 Outline of cording device Cording device is a device that is attached to the embroidery machine to sew cord string Changing position of attachment and spring can switch spec of cording looping Cording spec Looping spec Cording Looping 2 IA10 Preparation before using the device 2 Checking of position of cord presser set 1 Move the shaft as shown in the illustration below to put the pin into the groove Stopper FR Shaft p 3 Turn the main shaft by hand to set it to the position of lower dead point Position of lower dead point angle display of the main shaft differs depending on model Model Position of lower dead point Arm type 180 Bridge type 178 Arm type Bridge type IA10 Preparation before using the device 4 Lower the needle bar by hand to check if the needle is alig
13. ce J i Cushion ring Cord release pin gt gt j Screw Needle D Lower thread guide for KB 2M 8 IA10 IA10 Switching of spec looping cording 3 Change detaching of presser foot To change to cording spec remove the standard type presser foot When the noise reduction type presser foot is attached to the machine replace it with the presser foot for cording Standard type Noise reduction type TEJT C TFGN series TFMX series TFKN TLFD II TMLH II mixed type TCMX mixed type Presser foot for cording In case of standard type presser foot 3 1 Detaching of top cover 1 Detach the tension base cover and disconnect the connector 2 Remove the screw to detach the tension base 3 Remove the screw to detach the top cover Tension base Tension base cover Top cover F Fr Connector Switching of spec looping cording 3 2 Detaching of presser foot 1 Loosen the screws 1 and screw 2 to move up the needle bar 2 Remove the spring presser foot and cushion ring gt Needle bar Spring Ke Screw 1 Presser foot Screw 2 __ __ ae GS Cushion ring G 3 3 Attaching of cord release pin and needle 1 Lower the needle bar and fix it using the screw 1 temporarily 2 Attach the cord release pin and needle to the needle bar and fix them using t
14. chine remove the standard type presser foot When the noise reduction type presser foot is attached to the machine replace it with the presser foot for cording Standard type Noise reduction type TEJT C TFGN series TFMX series TFKN TLFD II TMLH II mixed type TCMX mixed type Presser foot for cording In case of standard type presser foot 3 1 Detaching of top cover Reference 7 Detaching of top cover P 9 3 2 Detaching of presser foot Reference 7 Detaching of presser foot P 10 3 3 Attaching of cord release pin and needle Reference 7 Attaching of cord release pin and needle P 10 3 4 Adjustment of lower dead point Reference 7 Adjustment of lower dead point P 11 3 5 Adjustment of upper dead point position Reference 7 Adjustment of upper dead point position P 12 3 6 Attaching of upper thread locking device Reference 7 Attaching of upper thread locking device P 12 3 7 Attaching of tension base and top cover Reference 7 Attaching of tension base and top cover P 13 In case of noise reduction type presser foot 3 8 Change of presser foot Reference 177 Change of presser foot P 14 3 9 Attaching of upper thread locking device lower thread guide and cord release pin Reference Attaching of upper thread locking device lower thread guide and cord release pin P 14 26 1A10 When attaching device for the first time cording 4 Attaching of main body of cording d
15. ction of the upper dead point stopper is bad it will touch other parts to cause failure Cushion ring Screw Upper dead point stopper 3 6 Attaching of upper thread locking device 1 Fix the upper thread locking device using the screws Upper thread locking device 12 IA10 3 7 Attaching of tension base and top cover 1 Switching of spec looping cording Fix the tension base using the screw 2 Insert the connector and attach the tension base cover 3 Fix the top cover using the screw Tension base Tension base cover Connector Top cover IA10 13 Switching of spec looping cording In case of noise reduction type presser foot 3 8 Change of presser foot 1 Remove the screw to detach the presser foot 2 Fix the presser foot for cording using the removed screw Presser foot for cording Presser foot 3 9 Attaching of upper thread locking device lower thread guide and cord release pin 1 Fix the upper thread locking device to the needle bar case using the screws 1 In case of models without upper thread locking device fix the lower thread guide for KB 2M using the screw 2 Attach the cushion ring cord release pin and needle and fix them using the screw Upper thread locking device J Cushion ring a u ak Cord release pin fA IE Screw Needle
16. d by stitch data as shown in the illustration below 1 Anexample of stitches in circular motion 2 An example of stitches in reciprocating motion 2 0 2 5mm lt gt 89 6 O 99 GE An example of finishing of sewing 6 IA10 Preparation before using the device 6 Height adjustment Perform adjustment when using thick fabric or thick cord 6 1 Height adjustment of cording 1 Loosen the screw to adjust height of the cord presser set 2 Fix the height using the collar and tighten the screw Collar Cord presser set 6 2 Height adjustment of looping 1 Loosen the screw to move up and down the stopper guide to adjust height of looping 2 Tighten the screw Loop large Stopper guide set Y Screw Loop small IA10 7 Switching of spec looping cording Switching of spec looping cording 1 Detaching of cover 1 Detach the face plate Position of screw hole of face plate differs depending on model lt Face plate 2 Detaching of lower thread guide and cord release pin 1 Remove the screws to remove the upper thread locking device When the lower thread guide for KB 2M is attached to the machine remove the screws to detach the lower thread guide for KB 2M 2 Loosen the screw of the cord release pin and remove the cushion ring cord release pin and needle Upper thread locking devi
17. ead point refer to p 3 4 Loosen the screw to lower the needle bar by hand so that the center of the hole of the cord presser C set is aligned with the tip of the needle and then tighten the screw Select the hole that fits to thickness of cord to sew Needle Needle Screw Cord presser C set Using thick cord Using thin cord 2 3 Attaching of cord guide Reference Attaching of cord guide P 28 3 Attaching of bobbin bracket set Reference Attaching of bobbin bracket set P 29 4 Attaching of face plate Reference 7 Attaching of face plate P 30 IA10 33 When cording device is not used When cording device is not used 1 Bobbin Roll up cord to the bobbin and insert the tip of the cord to the cord stopper spring 2 Clutch collar In case of looping spec pull the clutch collar to release the shaft Clutch collar when cording device is not used set the shaft guide pin securely to the groove of rear side When performing embroidery with the shaft guide pin not set to the groove of rear side the cording device will touch the embroidery frame or the middle supporter which could cause the cording device embroidery frame etc to be broken 3 Cord guide shaft Move the shaft as shown in the illustration below to put the pin into the rear groove 34 1A10 Parts list Parts list
18. es TFMX series TCMX mixed type Split Collar Presser Foot 090460040020 Lower Thread Guide Set FXP626S1 For TCMX mixed type Lower Thread Guide FXP62601 Thread Guide FX0626110000 Pan Head Screw M4 8 S160040801SD Thread Hook Spring EF0631020300 For 6 Needle M C Tensile Spring No 2 0 6mm Dia 507506010020 For 9 Needle M C Tensile Spring No 2 0 6mm Dia 507506020020 For 12 Needle M C Pan Head Screw M4 15 S160041501SD Clamp Thread Hook Spring 0B0200170012 For 12 or more Needle M C Truss Head Screw M3 4 S130030402SD Note As for parts with marks or please follow our instructions on Table of Contents in your parts order IA10 1st Edition April 1999 2nd Edition February 2000 3rd Edition November 2001 4th Edition July 2002 5th Edition July 2003 6th Edition October 2005 m Manufactured by Tokai Industrial Sewing Machine Co Ltd NO 1800 Ushiyama cho Kasugai Aichi pre 486 0901 Japan Telephone 568 33 1161 Fax 568 33 1191 m Distributed by Tajima Industries Ltd 19 22 Shirakabe 3 chome Higashi ku Nagoya 461 0011 Japan Telephone 52 932 3444 Fax 52 932 2457 m Authorized Distributor Copy reprint and reform of a part or whole of this manual without our permission is prohibited
19. evice 4 1 Attaching of main body of cording device 1 Fix the base and bracket spacer to the needle bar case using the screw 1 temporarily 2 How to attach the base differs depending on spec of needle bar case e When the machine has attaching hole for cording device fix the base and washer to the needle bar case using the screw 2 temporarily e When the machine has attaching hole for sequin device fix the base and collar to the needle bar case using the screw 2 temporarily e When the machine does not have attaching hole on the needle bar case fix the base C and spacer C to the needle bar case using the screw 3 and then fix the base to the base C using the screw 4 3 Fix the stopper guide set to the base using the screw 5 4 Fix the thread course to the stopper guide set using the screw 6 Attaching hole for KB 2M exists Attaching hole for sequin device exists Screw 2 LA I lt Q Xo Thread course oy Screw 3 Oxy WY Screw 4 RS Base S we Stopper guide set Screw 1 4 2 Adjustment of cord presser A set 1 Put the shaft guide pin into the groove as shown in the illustration below Shaft guide pin IA10 27 When attaching device for the first time cording 2 Turn the main shaft counterclockwise by hand to set it to the position of lower dead point refer to p 3 3 Loosen the screw 1 screw 2 and screw 3 to push down the needle bar by hand so that the center of the ho
20. feed hole a Needle Cord presser A set L Cord presser A set Screw SO 5 Loosen the screw of the collar to adjust collar position so that a clearance between the bottom face of the cord presser A set and the needle plate becomes about 1 mm and then tighten the screw Perform adjustment so that the cord presser A set pushes the fabric and cord lightly according to thickness of the fabric and thickness of cord to use Cord presser A set 2 Tee Cord presser A set Cord a Fabric t Needle plate 16 IA10 Switching of spec looping cording 6 Attaching of face plate 1 Attach the face plate Position of screw hole of face plate differs depending on model ___ Face plate IA10 17 Change of spec cording looping Change of spec cording looping 1 Detaching of cover Reference 7 Detaching of cover P 8 2 Detaching of lower thread guide and cord release pin Reference 177 Detaching of lower thread guide and cord release pin P 8 3 Change attaching of presser foot When presser foot is not attached attach standard type presser foot When presser foot for cording is attached replace it with noise reduction type presser foot Standard type TEHX C Noise reduction type TEJT C TFGN series TF
21. g this device are described in below signal terms that follow warning marks in this manual be sure to observe them Definitions of signal terms are as follows Indicates that there is a likelihood of death or serious injuries 1 if the instruction is not observed Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury 2 or property damage 1 A condition caused by electric shock injury fracture of a bone etc that leads aftereffect or an injury that necessitates hospitalization or visits to a hospital over a long period 2 It does not necessitate hospitalization or visit to a hospital over a long period Prohibited items A Items that may cause electric shock if not observed Q Items that must be followed carefully to ensure safe operation LH Items that explain the contents of sentences in detail and items that complement the contents IA10 Contents IA10 Contents Items to notice when using this device Preparation before using the device 1 Outline of cording devic 5 625645 dad fee RE D daca Re Os 2 2 Checking of position of cord presser set 3 3 Attaching Of bobbins eren e A Aree aah heen aaa ina ati 2 4 A Settin Ol Cord PEE NLE see tee ate ag Met Na habeas ee AN fost ds ads sate 5 5 Creating procedure of stitch data niesiniliaiiiisnthe sistema 6 581 Stitch length of cording Assassin SUSE hr 6 5 2 Stitch length of looping
22. h down the needle bar and tighten the screw in the state of the bottom of the needle bar touched to the upper face of the lower dead point gauge Pay attention to the direction of the needle bar connecting stud Lower dead point gauge Needle bar Screw __ Needle bar connecting stud I I Lower dead point gauge AIG 4 5 LS 20 IA10 Change of spec cording looping 3 5 Adjustment of upper dead point position 1 Turn the main shaft counterclockwise by hand to set it to the position of upper dead point angle of the main shaft 0 degree 2 Tighten the screw at the position where the upper dead point stopper touches the cushion ring lightly QAdiust the upper dead point stopper so that head of the screw faces to the front If direction of the upper dead point stopper is bad it will touch other parts to cause failure Cushion ring Upper dead point stopper 3 6 Attaching of upper thread locking device 1 Fix the upper thread locking device to the needle bar case using the screws Upper thread locking device 3 7 Attaching of tension base and top cover Reference 177 Attaching of tension base and top cover P 13 IA10 21 Change of spec cording looping In case of noise reduction type presse
23. hand so that the center of the hole of the cord presser C set is aligned with the tip of the needle and then tighten the screw Select the hole that fits to thickness of cord to sew Needle Screw C J Cord presser C set Using thick cord Using thin cord 6 Attaching of face plate Reference gt Attaching of face plate P 17 24 1A10 When attaching device for the first time cording When attaching device for the first time cording This is an explanation for work when attaching cording device cording spec for the first time 1 Detaching of face plate 1 Detach the face plate Position of screw hole of face plate differs depending on model 2 Remove the thread suspender disk and screw mounted at the left side of the needle bar case lt t Face plate TA C ly Thread suspender disk 2 Detaching of upper thread locking device lower thread guide and needle clamp 1 Loosen the screw to detach the upper thread locking device LI Incase of model that is equipped with lower thread guide remove the lower thread guide 2 Loosen the screw to remove the cushion ring needle clamp and needle Upper thread locking device Cushion ring ee O Needle clamp 3 Screw Needle gt IA10 25 When attaching device for the first time cording 3 Change detaching of presser foot When attaching cording device to the ma
24. he screw 3 3 Loosen the screw 1 that is fixed temporarily Screw 1 Needle bar Cord release pin a Er A A Screw 3 Needle Pay attention to the direction of the cord release pin 10 1A10 IA10 Switching of spec looping cording 3 4 Adjustment of lower dead point 1 Remove the needle plate and turn the main shaft counterclockwise to set it to the position of lower dead point refer to p 3 2 As shown in the illustration below align the notch part of smaller side of the lower dead point gauge with needle 3 Push down the needle bar and tighten the screw in the state of the bottom of the needle bar touched to the upper face of the lower dead point gauge Pay attention to the direction of the needle bar connecting stud Lower dead point gauge Needle bar Screw __ Needle bar connecting stud 11 Switching of spec looping cording 3 5 Adjustment of upper dead point position 1 Turn the main shaft counterclockwise by hand to set it to the position of upper dead point angle of the main shaft 0 2 Tighten the screw at the position where the upper dead point stopper touches the cushion ring lightly QAdiust the upper dead point stopper so that head of the screw faces to the front If dire
25. ide and cord release pin 18 3 Change attaching of presser foot sr 18 In case of standard type presser foot 3 1 Detaching of tension base and top cover cccccesecssecseceseeseceeceseeeecesceeeeaeeaeecaecaeceaeeneeeaeens 18 3 2 Attaching of presser footer cette ne ceed i eR ee 18 3 3 Attaching of cord release pin and needle 19 3 4 Adjustment of lower dead point 20 3 5 Adjustment of upper dead point position 21 3 6 Attaching of upper thread locking device 21 3 7 Attaching of tension base and top cover 21 In case of noise reduction type presser foot 3 8 Change of presser foot 22 3 9 Attaching of lower thread guide for cording and cord release pin nee 22 Contents A S witching Of per an Ras mn R AE RS ete et Mere 23 4 1 Detaching of cord presser A set and cord presser spring 23 4 2 Attaching of cord presser C set and cord presser spring 23 5 Adjustment of cord presser C Set ss 24 6 Attaching Of face plate tin 0er eee cele da eet sith coated een acc re ANDRE 24 When attaching device for the first time cording 1 Detaching of face plates nennen si ana Inn NR 25 2 Detaching of upper thread locking device lower thread guide and needle clamp 25 3 Change detaching of presser foot ss 26 In case of standard type presser foot 3 1 Detaching Of top cover a eos MARR ethan 26
26. le of the cord presser A set is aligned with the tip of the needle and then tighten the screws When needle does not stick on cord during cording perform adjustment so that the cord feed hole comes nearer to the needle 4 Loosen the screw 4 to adjust position of the collar so that the bottom face of the cord presser A set and the needle plate becomes about 1 mm and fix the collar using the screw 4 Perform adjustment so that the cord presser A set pushes the fabric and cord lightly according to thickness of the fabric and thickness of cord to use Cord feed hole Cord presser A set e Cord ae Pa L x Imm nn a Fabric Needle plate 4 3 Attaching of cord guide 1 Fix the cord guide to the base using the screw Cord guide Screw _ a 28 IA10 When attaching device for the first time cording 5 Attaching of bobbin bracket set Attaching method of bobbin bracket set differs depending on model and the number of needles Rotary typeTension base Tension base TITS 7 X Conte Aone on iol o l a re re A O O 5 1 Model equipped with rotary type tension base Attaching of bobbin bracket set 1 Remove the screw of the tension base 2 Attach the bobbin bracket set to the tension base using the screw Bobbin b
27. ned with the center of the hole of the cord presser set If the position is misaligned loosen the screw to adjust position of the cord presser set LI In looping spec select hole suitable for material to be sewn Cording spec Looping spec Needle Needle Cord presser set Cord presser set 3 Attaching of bobbin 1 Pull the holder spring to the outside to rotate it downward Holder spring 2 Set the bobbin to the bobbin shaft and return the bobbin to the original position while pulling the holder spring to the outside Pay attention to the direction of bobbin Bobbin Bobbin shaft 4 IA10 Preparation before using the device 4 Setting of cord 1 Set cord as shown in the illustration Looping spec CI In looping spec select hole suitable for material to be sewn IA10 5 Preparation before using the device 5 Creating procedure of stitch data Creating procedure of stitch data is different in cording and looping 5 1 Stitch length of cording Stitch length differs depending on thickness of sewing thread thickness of cord to be sewn and design Usually perform setting within a range of 1 5 to 2 0 mm Set stitch length to about 1 5 mm at sharp curved section oo length a 4 Stitch length 5 2 Stitch length of looping Stitch data differs depending on thickness of sewing thread thickness of cord to be sewn and design Basically sewing is performe
28. r foot 3 8 Change of presser foot 1 Loosen the screw to detach the presser foot for cording 2 Attach the noise reduction type presser foot and fix it using the screw Presser foot 3 9 Attaching of lower thread guide for cording and cord release pin Reference L7 Attaching of upper thread locking device lower thread guide and cord release pin P 14 22 IA10 Change of spec cording looping 4 Switching of spec 4 1 Detaching of cord presser A set and cord presser spring 1 Loosen the screw to remove the cord presser A set and spring from the shaft 2 Loosen the screw to remove the collar S car 7 For Set screw 4 2 Attaching of cord presser C set and cord presser spring 1 Insert the spring to the shaft and attach the collar and then fix them using the set screw 2 Attach the cord presser C set to the shaft and fix it using the screw temporarily SD collar gt 2 Fe Set screw Spring IA10 23 Change of spec cording looping 5 Adjustment of cord presser C set 1 Put the shaft guide pin into the groove 2 Push the clutch collar so that the stopper touches upper face of the shaft To adjust height size of loop to be sewn refer to Height adjustment p 7 3 Turn the main shaft counterclockwise by hand to set it to the position of lower dead point refer to p 3 4 Loosen the screw to lower the needle bar by
29. racket set 29 IA10 When attaching device for the first time cording 5 2 Other models Other models models of 12 or less needle head without rotary type tension base Attaching of bobbin bracket set 1 Loosen the two first tension studs at left side to remove the first tension and first tension thread guide First tension wa First tension stud First tension a First tension stud a aa Tension base First tension thread guide 6 Attaching of face plate 1 Attach the face plate Position of screw hole of face plate differs depending on model __ Face plate 30 IA10 When attaching device for the first time looping When attaching device for the first time looping This is an explanation for work when attaching cording device looping spec for the first time 1 Attaching of cord release pin 1 Loosen the screw to remove the needle and needle clamp 2 Attach the cord release pin in stead of the needle clamp with the needle Do not take off the cushion ring Q In case of model that has lower thread guide remove the face plate and replace the lower thread guide with that for KB 2M _i Face plate E A amp Needle 7 clamp Lower thread guide for KB 2M AIO Cushion ring IA10 31 When attaching device for the first time looping 2 Setting of main body of cording device 2 1 Attaching

Download Pdf Manuals

image

Related Search

Related Contents

デジタル画像レコーダー SHR-4040 取扱説明書 クラス A デバイス(工業  Information destinée au patient du NAR    Modelo serie 37010  Crucible V6/N1.indd  none 0881009 Use and Care Manual  User Manual  SERVICE MANUAL  6 - Firmware Center  (Libro Inst. Lis TE Castellano Edición 2 del 26-3-2012)  

Copyright © All rights reserved.
Failed to retrieve file