Home

USER MANUAL - Dreamrider Online

image

Contents

1.
2. 3 Window Kit Installation The window kit has been designed to fit most standard vertical and horizontal windows However it may be necessary for you to modify some aspects of the installation procedures for certain types of windows Please refer to the illustrations Fig 7 and Fig 8 Vertical Window Window Slider Kit Minimum 35 90cm Maximum 51 130cm Window Slider Kit Minimum 35 90cm Maximum 51 130cm Fig 8 4 Mounting illustrations REMOTE CONTROL 1 mounting in the wall L gt Power Press this button to turn off the unit Timer Press this button to set the timer Swing Press this button to make the vertical louver swing automatically UT Vary from Celsius degree to Fahrenheit degree Cool Press this button to choose Cool mode Heat Press this button to choose Heat mode 2 correct bending Dry Press this button to choose Dry mode Fan Press this button to choose Fan mode 2 Up Press Up or Down button to set temperature Y Down or adjust the time in Timer mode High Press this button to select high fan speed YPC H remote control Fig 4 Med Press this button to select middle fan speed Fig 10 Fig 11 Low Press this button to select low fan speed 3 wrong bending Econ Press this button to a set energy saving mode only in Cool and Heat mode The set temperature is 27 C in cool mode and 23 C heat mode The fan speed is low These data cant be changed
3. Wash the air filter by immersing it gently into warm under 40 C or 104 F water with neutral detergent Rinse the filter and dry it in a shaded place 3 Push the air filter back into the original position End of season 1 Pull out the plug from the drain mouth and remove the water from the drain pan You can remove the water entirely by slanting the unit back Setting the fan mode then press the Fan button for 5 seconds until the lower fan works After that operate the unit in fan mode for half a day until the pipe is dry In this way the inside of the unit can be dried and the mildew growth can be suppressed 2 Switch off the unit and disconnect the plug from the power supply 3 Tie the cable with sting 4 Remove the air exhaust duct and keep it carefully 5 Wrap the unit with the plastic bag and keep it in a dry place 6 Take the batteries out of the remote control and keep them well FEATURES AND PARTS LIST Features e No installation is required e Easily moved The handle makes moving more convenient e Streamline colorful screen display e LED colorful screen display e Water cooled mode is most energy saving and environment protect e Low noise and strong wind e Unique economic function Auto swing makes wind blow from left to right automatically e Three minute restart delay to protect compressor Parts list 1 control panel 2 horizontal louver 3 vertical louver 4 air inlet grille
4. accordingly Press again to cancel it when or is flashing D Power press this button to turn on off the unit 2 LED display Timer indicator EDO Dry cool fan and heat mode indicator no 8 in YPC C models HOS High middle and low fan speed indicator Sj Water Full indicator Water Injection indicator i IR receiver window Indicate the time and temperature Display EX X 2 3 when there is something wrong refer to Self diagnosis function Display E4 when coil is defrosted C F Celsius degree and Fahrenheit degree indicator 5 WATER DRAINGE METHODS This product has a self evaporative system The condensing water will recycle to cool the condenser This water cooled mode can not only improve cooling efficiency and decrease noise but also save energy for you When in cooling mode the water from the evaporator will flow into a inside pan When the water reaches the low level the water pump will work until the water is under the low level When the water reaches the high level the compressor will stop working and the water pump lower fan motor and upper fan motor will work on all the time When in heating mode the water pump won t work When the water is full the water full indicator will light and the compressor will stop working The buzzer will buzz 10 times every 5 minutes until the water is below the high level or drained by hand When the alarm stops and after three minutes restart delay t
5. 9 castor 6 exhaust duct 7 handle 8 air outlet grille 9 power cord and plug 10 water injection port 11 power and hook 12 air filter JD W TIN 1 j il 4 If Y ANI 1411 OPERATION METHODS Timer set 1 Set timer off Press the Timer button when the unit is on The LED will flash _ five Times During this period press Up or Down button to adjust set time from 0 5h to 24h It will vary 0 5h each time in 3h and 1h each time hereafter The set time will flash 5 times after adjusting When it will display temperature again Once the set time end the unit will turn off automatically 2 Change the set time When Timer is on you can check remnant time by pressing Timer button It will flash 5 times Press Up or Down button to adjust set time The set time can also be cancelled if you press the Timer button once again during the flashing time 3 Set timer on Press the Timer button when the unit is off Same as timer off set Once the set time end the unit will turn on automatically Cooling Heating and Dehumidifying operation 1 Cooling Heating operation Press Mode button or to choose Cool heat mode Press Up or Down button or Le to set a proper room temperature The range is 18 30 C 64 86 F The temperature will increase or decrease 10 or 1 F each time Press Speed button or Luf to choose a proper fan speed Press Swing
6. NG PERMISSIBLE EXCESSIVE OPERATING 1 5MPa 4 5MPa PRESSURE SUCTION DISCHARGE MAXIMUM ALLOWABLE PRESSURE 2 0MPa 5 5MPa LOW PRESSURESIDE HIGH PRESSURE SIDE AIR FLOW 580m h NOISE 56dB A NET WEIGHT 44 kg DIMENSION WxHxD 370x815x595mm c 14 Energy Saving Tips Do not cover or restrict the airflow from the Outlet or Inlet grills e The minimum distance from furniture and wall should be 50cm e Keep blinds and or draperies on any windows closed during the sunniest part of the day e Keep the filters clean Under normal conditions the filters should be cleaned approximately every 30 days Since the filters remove airborne particles more frequent cleaning maybe necessary depending on the indoor air quality e Set the fan speed switch to high cool and the thermostat to the coolest position for the initial start up then set the Fan switch to Low cool and lower the thermostat to a comfortable setting TROUBLE SHOOTING Before contacting professional service please firstly check it yourself referring to the followings Trouble s power fail Is plug out Insert the plug into the The unit doesn t socket steadily l operate at all Is power fuse or switch off Change the fuse or switch on Is the set time suitable Change the set time Is water full alarm on Pour the water e et bloc e blocks l l Is there any ove the heat source Cooling Hating source in room ee efficiency is not Are air fi
7. USER MANUAL PORTABLE AIR CONDITIONER CONTENTS SPEGIFIGATIONS APPENDIX IMPORTANT SAFEGUARDS 0 cccccccccccccccscccesccccssccecsececsecccsecccssscecseseeceseceaees 2 Fuse Parameter FEATURES AND PARTS LIST 0000 cccccccccccccccccsscecssccecsececscecsesecssssecsersecssessaees 4 Type FSD PANEL CONTR eee 5 Voltage 250V Current 3 15A REMOTE CONTROLE 0 amil la aia a atkal nim 6 OPERATION METHODS aa 7 Y INSTALLATI N 8 EES WATER DRAINAGE 10 Disposal Do not dispose this product as unsorted municipal waste Collection 11 such waste separately for special treatment is necessary TROUBLE SHOOTING u 0 ccccccccccccccccccccccccessececccssscecssccecsecccscecseeccesscecseceecsauenseees 12 INSTALLATION ACCESSORIES 0 ccccccccccccccccsscccssccccsscecscecsececssscecsessesseceeees 13 nissan iris drenan 14 PORTABLE AIR CONDITIONER MODEL Airo 2 RATED COOLING CAPACITY 4 40kW 15000BTU PEAK COOLING CAPACITY 5 68kW 18000BTU RATED HEATING CAPACITY 4 84kW 16000BTU PEAK HEATING CAPACITY 6 04kW 19000BTU REFRIGERANT CHARGE R410A 8209 POWER SUPPLY 240V 50Hz RATED INPUT COOLING 1950W HEATI
8. button or to adjust the direction of vertical louver Adjust horizontal louver by hand 2 Dehumidifying operation Press Mode button or to choose Dry mode The fan speed is Low LED displays room temperature These cannot be adjusted NOTE 1 In cool mode when the water Injection indicates lights you can inject some water through the injection port before cooling operation no longer than High level 2 You Should drain water with the drainpipe in heat and dehumidifying mode The unit will stop work when water level exceeds the high level 3 Do not use air exhaust duct when in Dry or Fan modes 4 If your room is directly exposed to the sun draw the curtains please 7 INSTALLATION 1 Selection of Installation Place Install the unit on a flat and dry place Leave at least 50cm space around the unit when the hose is not connected Fig 5 2 AlR Exhaust Duct Mounting Method 1 Fix the square end of the exhaust dust to the exhaust terminal of the unit 2 Put the other end discharge to the nearest window Leave at least 50cm place around it NOTE The length of the air exhaust duct is between 60cm to 170cm or 180cm adapters included We suggest using the minimum length of the air Fis 6 exhaust dust That can save energy for you 18 This length has been designed especially according to the specifications of the air conditioner Do not use an extension or exchange of a different hose as that may lead to malfunction
9. he unit will work normally You can drain the water out with a drain pipe It is included in the accessory But first you should put some vessel like pan under the hose then take out the plug on the drain mouth thus the water will flow into the vessel and won t make the floor wet Fig 13 If the drainpipe is shorter than you need you can purchase a pipe 9mml D Then connect it to the drainpipe with the drainpipe kit we supply Move the unit gently when the water is high If not the water may spill from the inside of the unit When the water in the cave is not enough for pumping the pump will stop working At the same time the Water Injection indicator on the control panel will illuminate X you had better inject some water into the water draw carefully In order to avoid the water flooding from the under pan you should inject water not more than 1800ml three cups This operation helps save 20 30 energy for you MAINTENANCE Cleaning Turn off the unit and pull the plug out of the socket before any cleaning 1 Clean the surface Clean the surface of the unit with a duster or a half wet soft cloth Do not use chemical solvent like benzene alcohol gasoline and etc Or the surface may be damaged or even deformed 2 Clean the air filter If the air filter is blocked with a lot of dust the efficiency will reduce You d better clean the filter every two weeks 1 Pull out the air filter as Fig 14 2
10. la bala Only for YPC 07 09 12 S model Water 0191 oe eee 1 pc Y Drain pipe juu 3 8 screw Window Exhaust Flexible Exhaust hose Adapter i watercup Adjustable Window Slider Kit 35 51 13 IMPORTANT SAFEGUARDS Important Safeguards Read all instructions eDisconnect the power plug before dismantling assembling or before cleaning eAvoid touching mobile parts of the appliance Never insert fingers pencils or any other objects though the guards whenever the power plug is connected especially while running The appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the unit safely Young children should be supervised to ensure that they do not play with the appliance Do not use the appliance for any other purpose than its intended use The appliance must not be used if the guards are not fastened according to instructions When the power cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard not use your appliance with an extension cord unless it has been checked and tested by a qualified electrician or electrical supplier Return to Hagemeyer or authorized service agent The air conditioning unit must always be stored and transported upright othe
11. lters very dirty Clean the air filter good Is the set temperature Change temperature suitable Is fan speed set at low Select suitable fan speed l is e inner liquid It is normal Too noisy and flowing inside o vibration s it inclined Place it in a flat place s the voltage normal urn off the unit e l l voltage is abnormal The unit starts Is the exhaust tube fixed Set the exhaust tube and stops ony or is it bended correctly frequently ave you added extra Remove the extra tube exhaust tube Stop running and pull the plug out in case something enumerated below happens Then contact the professional service for help e The fuse and switch often break e The power cord superheat or sleeve of the cord is broken e There is abnormal odor or smoke comes out of the unit Self diagnosis function Check code Diagnosis of malfunction E2 Room temperature faults E Faulty coil temperature Note When display E4 it means that the coil is defrosted That is the normal status INSTALLATION ACCESSORIES Description Flexible exhaust hose with adapters 1 set DP 15cm Stretch from 36cm up to 150cm Window exhaust adapter flat mouth 1pc Adjustable window slider Kit 1 set From 35 3 8 90cm up to 51 1 8 130cm Screw the length is 3 8 EIA DARIA 1pc Drain pipe PE
12. rwise you may cause irreparable damage to the compressor in case of doubt we suggest to wait for at least 24 hours before you start the air conditioning unit eAvoid restarting the air conditioning unit unless 4 minutes have passed since being turned off or the compressor may get damaged Never use the mains plug as a switch to start and turn off the air conditioning unit Use the provided ON OFF switch located on the control panel Always place the portable air conditioner on a dry stable surface PANEL CONTROL CAUTIONS If the unit is turned off in cool dry heat mode and restarted immediately then it will wait at least 3minutes before running again FS Y OSA E Cr a Fig 3 1 Buttons Timer press this button to set the timer A Swing press this button to make the vertical louver swing automatically Press once again the swing will stop Speed press this button for 5 seconds to select high middle or low fan Speed Up down press up or down button to set temperature or adjust the time in A V Timer mode Press both buttons to vary from Celsius to Fahrenheit Mode press this button to select cool heat dry or fan mode heat mode only in YPC H models Y Econ press this button to a set energy saving mode only in heat and cool mode This set temperature is 27 C in cool mode and 23 C in heat mode The fan speed is low These data can t be changed The LED display will flash or

Download Pdf Manuals

image

Related Search

Related Contents

Lautrec Holiday Home Brochure  O-250 AW of IM OL(A3)  Samsung KA66 Инструкция по использованию  TT-3026L/M/S User Manual  GCX03T_FN-143_CL IgE.indd  `APPY HOLIDAYS® LIGHTS AND SOUNDS OF  OLK XXX Tender for Supply of geological equipment  目次(index_ver8)  TX807 - Wiki Karat  Massive Wall light 33006/17/10  

Copyright © All rights reserved.
Failed to retrieve file