Home
FP3900-T - Pro-face America HMI Store
Contents
1. 60 023 75 029 78 750 ms 1280x1024 63 981 60 000 108 000 a 1280x1024 79 976 75 000 134 999 1 When you use this resolution set ON for 720 x 400 Mode in the OSD On Screen Display System Settings Pin Assignments and Signal Names for Analog RGB ae Signal Name ne Signal Name 4 Signal Name Pin Location 1 Analog R 6 Return R 11 Reserved 2 Analog G 7 ReturnG 12 DDC DATA 3 Analog B 8 Return B 13 H SYNC 4 Reserved 9 Reserved 14 V SYNC 5 Digital grounding 10 Digital grounding 15 DDC CLOCK 5 GOMNGECHOM casssnsssesnsessnroseanns Mini Dsub 15 pin male Connector set screw 44 40 UNC RGB cable manufactured by Pro face FP CV02 45 lt 4 5m gt IMPORTANT e If a cable other than the specified RGB cable is used product perfor mance cannot be guaranteed due to the possibility of noise interfer ing with the FP unit s operation m DVI D Interface Input signal type DVI D CONTRAST BRIGHTNESS eae lay DIMMER BACKLIGHT SHARPNESS Pay ALL RESET DEFAULT Display Area FP 3900T Series Size H Sync V Sync Dot Clock aa Display kHz Hz MHz H Horizontal V Vertical Resolution 640x400 31 469 70 000 25 175 FOR 640x480 31 469 59 992 25 175 640x480 35 000 66 670 30 240 x2 H 640x480 37 861 72 810
2. 31 500 x2 13 V 640x480 37 500 75 000 31 500 720x400 1 31 469 70 000 28 320 Sosa 300x600 35 156 56 250 36 000 io 1280x1024 800x600 37 879 60 317 40 000 IV 800x600 46 875 75 000 49 500 i 1024x768 48 363 60 004 65 000 125 H 1024x768 56 476 70 069 75 000 1 33 V 1024x768 60 023 75 029 78 750 i 1280x1024 63 981 60 000 108 000 E 1280x1024 79 976 75 000 134 999 i 1 When you use this resolution set ON for 720 x 400 Mode in the OSD On Screen Display System Settings Pin Assignments and Signal Names for DVI D Pin Signal Name Pin Signal Name Pin Signal Name Pin Location 1 TMDS DATA2 9 TMDS DATA 17 TMDS DATAO 2 TMDS DATA2 10 TMDS DATA1 18 TMDS DATA0 3 TMDS DATA2 14 TMDS DATA 19 TMDS DATAO SHIELD SHIELD SHIELD 4 NC 12 NC 20 NC i 5 NC 13 NC 21 NC TMDS CLOCK 24 6 DDC Clock 14 NC 22 SHIELD TMDS 7 DDC Data 15 GND 23 CLOCK 8 NC 16 Hot Plug Detect 24 TMDS CLOCK Connectol cceeeees DVI D 24 pin male Connector set screw 4 40 UNC Gablen iiie DVI D cable manufactured by Pro face FP DV01 50 lt 5 m gt FP DV01 100 lt 10 m gt IMPORTANT Hot Plug cannot be used e If a cable other than the specified DVI D cable is used product per formance cannot be guaranteed due to the possibility of noise inter fering with the FP
3. Groups A B C and D Hazardous Loca tions only e WARNING Explosion hazard substitu tion of components may impair suitability for Class I Division 2 e WARNING Explosion hazard do not dis connect equipment while the circuit is live or unless the area is known to be free of ignitable concentrations lt Control Drawing of USB I F on FP s Front Module gt The information below concerns the use of the USB I F located on the FP unit s front modules used in Class I Division 2 Groups A B C and D hazardous locations from Doc No 35016429 FP s Front Module USB Pin Description Nonincendive Field 2bo Wiring Apparatus 3 D 4 GND See note 1 for detail Shield Gnd kakka Notes 1 Nonincendive Circuit Parameters Front USB I F Voc 5 0 V Isc 1 25 A Ca 10 F La 16 pH 2 Selected Associated Nonincendive Field Wiring Apparatus shall satisfy the fol lowing Nonincendive Field _ Front module Wiring Apparatus of FP unit Voc lt Vmax Isc lt Imax Ca gt Ci C cable La Li L cable 3 If the electrical parameters of the cable are unknown the following values may be used Capacitance 60pF ft Inductive 0 20 uH ft 4 Nonincendive Field Wiring must be installed in accordance with article 501 10 B of the National Electrical Code ANSI NFPA 70 5 Nonincendive Field Wiring Apparatus shall not contain or be connected t
4. IMPORTANT except that black are shown on sides of the dis play Auto Gain Analog RGB only p Applies the setting and then returns to the top menu gt G hu Cancels the setting and then returns to the top menu mazaa gt Be sure to perform the auto gain control when the Icon decision screen has both 100 black and 100 white areas displayed Saves the setting and quits the OSD Saves all the adjusted settings in the EEPROM End of OSD Note Regardless of the above clause Digital Digital Electronics Corporation Electronics Corporation shall not be held responsible for any damages or third party 8 2 52 Nanko Higashi Suminoe ku claims for damages or losses resulting from Osaka 559 0031 Japan the use of this product URL http www pro face com The information in this document is subject to change without notice PFX105491L FP3900 MTO3E BTH 2010 10 JM C 2009 Digital Electronics Corporation 16
5. Phoenix Contact products Use the following wiring for FP Those are Phoenix Contact products Recommended Dri SZS 0 6X3 5 1205053 rivers Al 0 75 10GY 3201288 Al 1 10RD 3200182 Al 1 5 10BK 3200195 Al 2 5 12BU 3200962 Recommended stick end terminal Crimp tool for recommended CRIMPFOX ZA 3 stick end 1201882 terminal m Connecting the Power Cord When connecting the AC type power cord be sure to follow the procedures given below 1 Confirm that the power cord is unplugged from the power supply 2 Push the Opening button by a small and flat screw driver to open the desired pin hole 3 Insert each pin terminal into its each hole Release the Opening button to clamp the pin place Opening Button AC power supply cord S Ao Ol pL OE BN Ol DFe S 4 After inserting all three pins insert the Power Plug into the Power Connector at FP Fix the plug with two 2 minus screws IMPORTANT The torque required to tighten these screws is 0 5 to 0 6Nem To prevent the possibility of a terminal short use a pin terminal that has an insulating sleeve Using the USB Cable Clamp m USB Cable Clamp Attachment Pro cedure Installation to USB cable 1 Connect the USB cable to the connector 2 Insert the cable clamp into the cable clamp holder as shown in the following figure and tighten the clamp until the cable is secured in place US
6. 1 2 is used to display or hide the OSD To hide the OSD set the switch to ON To display the OSD set the switch to OFF The default setting is OFF OSD is displayed m SW2 Switch Setting Slide Switch is used to switch the data input output command control method on the touch panel between USB and RS 232C PE Serial The default setting is RS 232C gS 4 Interfaces m Analog RGB Interface Input signal type Analog RGB i Image signal analog RGB npu peas Synchronous signal TTL level negative true or positive true Pnatactenisus Scanning type non interlace CONTRAST BRIGHTNESS H POSITION V POSITION Setting by OSD H size PHASE On Screen Display 5iMMER BACKLIGHT SHARPNESS ALL RESET DEFAULT he number of dots pixels displayed are as follows Size H Sync V Sync Dot Clock ae Display kHz Hz MHz H Horizontal V Vertical Resolution x2 H 640x400 31 469 70 000 25 175 x2 56 V 640x480 31 469 59 992 25 175 640x480 35 000 66 670 30 240 x2 H 640x480 37 861 72 810 31 500 x2 13 V 640x480 37 500 75 000 31 500 4 x1 77 H 720x400 31 469 70 000 28 320 x2 56 V 800x600 35 156 56 250 36 000 1280x1024 800x600 37 879 60 317 40 000 eae 800x600 46 875 75 000 49 500 i 1024x768 48 363 60 004 65 000 ae 1024x768 56 476 70 069 75 000 eet 1024x768
7. ANT Normally the FP unit detects a backlight burnout b IMPORTANT monitoring the backlight s current flow however the FP may fail to detect this condition depending on the type of backlight problem I Detect 2 Point Touch Enables to halt the data output procedure when two points of the touch panel are pressed Default OFF lt Disable gt IMPORTANT When doing the touch operation on a screen like the desktop of Windows disable this function Depending on the conditions it may not be able to be detected that the two points were pressed gt Power on Buzzer Enables disables the buzzer sound in turning on the power Default ON lt Buzzer sounds enabled gt P USB Touch Panel ID Set the touch panel ID number using the number 0 to 3 when connecting to USB Default 0 Applies the setting and then returns to the top menu Cancels the setting and then returns to the top menu 15 All Reset jl Resets all the settings and then returns to the top menu Cancels the setting and then returns to the top menu Input Source 5 Switches Analog RGB and DVI D and quits the OSD gt I 3j Cancels the setting and then returns to the top menu D Auto Adjust Analog RGB only p Applies the setting and then returns to the top menu gt FSi Cancels the setting and then returns to the top menu Be sure to perform the auto adjust while things
8. B Cable USB cable clamp Stopper USB cable clamp holder USB Cable Clamp Removal Fea ture 1 Push in the cable clamp s stopper until the cable clamp is unlocked then remove the clamp 2 Disconnect the USB cable Power Supply Cautions Please pay special attention to the following instructions when connecting the power cord terminals to the FP unit e Ifthe power supply voltage exceeds the FP unit s specified range connect a voltage transformer e Between the line and the ground be sure to use a low noise power supply If there is still an excessive amount of noise connect a noise reducing transformer Input and Output signal lines must be sepa rated from the power control cables for operational circuits The FP unit s power supply cord should not be bundled with or kept close to main circuit lines high voltage high current or input output signal lines e Connect a surge absorber to handle power surges e To reduce noise make the power cord as short as possible The temperature rating of field installed conductors 75 C only Grounding Caution When attaching a wire to the FP unit s rear face FG terminal on the AC Connector be sure to create an exclusive ground Use a grounding resistance of 100Q a wire of 2mm or thicker or your country s applicable standard Input Output Signal Line Cau tions All FP Input and Output signal lines must b
9. FP 3900T Series Installation Guide ee Caution Be sure to read the Warning Caution Information on the attached sheet before using the product Package Contents E FP unit 1 E Installation Guide 1 this manual E Warning Caution Information 1 E Installation Gasket 1 attached to the FP unit E Installation Fasteners 4 set 3sets l 5 E USB Cable Clamp 1 BAC Power Connector 1 attached to the FP unit i Q p This unit has been carefully packed with special attention to quality However should you find anything damaged or missing please contact your local FP distributor immediately Required software Reference manual The FP 3900T unit needs the following software for operation As FP user manual provided by PDF media describes its details download the manual below and get the further information Visit Pro face website below and get both software and reference manual URL http www pro face com otasuke e Software Mouse Emulation Software e Manual FP3000 Series User Manual IMPORTANT Before you begin to use the touch panel you need to adjust calibrate it For use of USB for sending touch data the number of the calibration point of mouse emulation software should be 9 The initial setting is 4 If you do not change the setting values the touch position may not be accu rate a little off the point If the touch panel coo
10. System Settings gt filii Selection of the change item Adjustment button Click Tone Enables disables the click sound With this parameter the sound level can also be adjusted Default value OFF lt Click sound disabled gt I 720x400 Mode When an input data resolution of 720 x 400 is used in the VGA text mode set this parameter to ON For other resolutions set this parameter to OFF Default ON L Auto off Disp Enables disables the screen display Auto OFF function ando the time when the Auto OFF function is enabled Default OFF lt Auto OFF function disabled gt The Auto OFF function automatically turns off the display to prevent the screen from burning out when the touch panel is not used for some period of time With this parameter you can set the time interval to turn off the screen display how much time passes before the screen display is turned off when the touch panel is not used If the touch panel is not touched over the set time the backlight will automatically turns off Select the time period from 1 min 3 min 5 min 10 min and OFF Auto OFF function disabled I BL Alarm Enables disables the Backlight burnout detect function Default ON When a burned out backlight is detected the status LED flashes alternately green and red or a steady orange Touch operation will be disabled when the backlight burns out which prevents the FP from sending input signals to the PLC IMPORT
11. e separated from all operating circuit power cables e If this is not possible use a shielded cable and ground the shield Calibration of OSD Display Position BOSD Functions You can operate the FP screen menus via the touch panel and even if FP is operating adjust screen image display to a minute level The feature is called OSD On Screen Display The items that can be set with OSD and the functions are shown Example of OSD screen Color settings Eg E E E B E Camee AD a a e Ver indicates the version of the OSD Item Function Color Settings Adjusts the contrast and the brightness Screen Settings Adjusts the display position of the screen ST a Custom Display Adjusts Sharpness and the backlight brightness System Settings Changes settings such as activating the click sound All Reset Resets the current OSD value to the default value Input Source Switches Analog RGB and DVI D Auto Adjust Automatically adjusts the display position of the screen Analog RGB only SST lel 0 3 L Auto Gain Automatically adjusts the contrast and the brightness Analog RGB only ESC Cancels the setting and returns to the upper level SET Applies the setting and returns to the
12. ion gasket must be used even though it is not neces sary for its environment For installation refer to the FP3000 Series User Manual e Check that the installation panel or cabinet s surface is flat in good condition and has no jagged edges Also if desired metal reinforcing strips can be attached to the inside of the panel near the Panel Cut to increase the panel s strength 3 The following figures show the twelve 12 fastener insertion slot locations Insert each fastener s hook into the slot and tighten it with a screwdriver Top Installation fastener Panel 2 gt ss FP Right side ook Bottom Tightening the screws with too much force can damage the FP units case The necessary torque is 0 8 Nem Wiring WARNING e To avoid an electric shock when connecting the FP s power cord terminals to the power ter minal block confirm that the FP s power supply is completely turned OFF via a breaker or similar unit e To avoid the dangers of fire electric hazards and equipment damage be sure to use only the specified voltage when operating the FP e Since there is no power switch on the FP unit be sure to attach a breaker type switch to its power cord m Electrical Specification ttem Specification Rated Voltage AC100V AC240V Allowable Voltage AC85V AC264V Rated Frequency 507 60HZ 2 Allowable Frequency Range 40Hz 72H
13. mes used for the serial interface on FP units are designed to match the pin order used on most PC serial interfaces so that a straight cable can be used to connect the two Therefore connect each pin s signal to the same signal name on the PC side For example pin 2 RD should be connected to the RD input terminal on the PC s connector Refer to the FP3000 Series User Manual s section Cable Diagrams for each signal s direction m USB Interface Type B connector Up Stream Port Pin Assignments and Signal Names for USB Interface Pin No Signal Name Condition Pin Location 1 USB1 5V 5VIN 2 USBD1 USB data 2 3 USBD1 USB data 4 GND Ground Cablen USB cable manufactured by Pro face FP US00 If a cable other than the specified USB cable is used product performance cannot be guaranteed due to the possibility of noise interfering with the FP unit s operation 8 Installation 1 According to the Panel Cut size make installation holes on the panel Also determine the panel thickness according to the panel thickness range with due consideration of panel strength Unit mm in 1 0 04 Panel 4195 plt6 52 904 r lt 30 12 Panel thickness 1 6 0 06 to 10 0 39 FP 0 FP 13 88 0 04 2 Check that FP has installation fasteners Insert the FP from the front IMPORTANT Installat
14. n All the setting values even though in process of the OSD settings will be retained in condition of letting the OSD leave more than 30 seconds or by pressing the button The OSD will keep those values and make them effective until power off or a Reset command input Top Main A RGB Color Settings 3 er gt Ka Selection of the change item 4 Screen Settings Adjustment button P Contrast gt R Contrast p GContrast I B Contrast P Brightness Applies the setting and then returns to the top menu gt ZJB Cancels the setting and then returns to the top menu Adjustment button gt I Selection of the change item p H Position Analog RGB only I gt V Position Analog RGB only gt H size Analog RGB only P Phase Analog RGB only Display Clock Clock for output to TFT color display can be finely adjusted according to 9 levels Default 50 Please use to the default value normally Applies the setting and then returns to the top menu gt ZJB Cancels the setting and then returns to the top menu ce Custom Display Mili Selection of the change item gt Sharpness Dimmer gt Auto Adjust Enable gt OSD Transparent Adjustment button Applies the setting and then returns to the top menu Cancels the setting and then returns to the top menu 14 E
15. o another source of power CE Marking Notes The FP 3900T Series is a CE marked product that conforms to EMC directives and Low Voltage directives EN55011 Class A EN61000 6 2 and EN60950 1 First Edition Part Names Front View 2 D A B la Rear View Bottom View A TFT Color LCD Acts as a display monitor for your host B Touch Panel Allows you to switch screens or write data to the host C Power Connector Socket Provides the input and ground terminals for a power cable D Setting Switch By opening the cover the Dip switches and slide switch are seen Each switch can set a operation mode E Analog RGB Connector Connector for analog RGB interface F DVI D Interface Connector Connector for DVI D interface G Serial Connector Connector for serial RS 232C interface Used for sending touch panel data to the host H USB Connector Type B Connector for USB interface Used for sending touch panel data to the host or used as an upstream port for USB HUB I Front LED Used to indicate the condition of the power supply a backlight burnout or image signal input J Front USB Connector Type A FP3900 T41 U only A downstream port for embedded USB HUB in conformity with USB2 0 1 1 standard which is used for connecting USB devices Connect the upstream
16. port of the USB HUB H USB connector to the Host PC for Front USB connector use 3 Dimensions Unit mm in 419 16 50 z 777 35 Top View 127 3 06 0 14 460 18 11 0 50 H center of display area z O al g7 ai _ N g g oO nter of unit re Bs lt 5 g Front View Side View Dip Switches and Slide Switch The Dip Switches and Slide Switch are located in the bottom of the FP unit Loosen the screws of the cover with a Phillips head screwdriver and then remove the cover After setting the dip switches and slide switches reinstall the cover and screws with the screwdriver The tightening torque for those screws is 0 5 0 6 Nem Only the settings when the power supply is turned on is effective to the Dip Switches and the Slide Switch After changing the settings of the Dip Switches and the Slide Switch be sure to restart your FP unit ca Cover Bottom view Dip Switches SW1 Slide Switch SW2 m SW1 Switch Setting SWTI I Reserved Always OFF SWI 5 Reserved Always OFF 12345678 SWI 2 Display Hide the OSD SWI 6 Reserved Always OFF bloo bal bal I SWT 3 Reserved Always OFF SWI 7 Reserved Always OFF SWI 4 Reserved Always OFF SWI 8 Reserved Always OFF e SW1 2 Dip Switch SW
17. rdinates slip it is recommended to make calibration again UL c UL CSA Application Notes lt Cautions gt Be aware of the following items when building the FP into an end use product The rear face of the FP unit is not a part of an enclosure This unit must be used as a built in component of an end use product that forms a UL c UL compliant enclosure For indoor use only e This unit should be installed in the front face of a metal panel If this unit is installed so as to cool itself naturally be sure to install it in a vertical panel Also be sure that the FP unit is mounted at least 100 mm away from any adjacent structures or equipment If these requirements are not met the heat gener ated by the FP unit s internal components may cause the unit to fail to meet UL c UL standard For use on a flat surface of a Type 4X Indoor Use Only and or Type 12 Enclo sure Type 4X Indoor Use Only and or 12 Enclosure when the hatch for Front USB Port is secured by screw Type 1 Enclosure when the hatch for Front USB Port is open FP3900 T41 U only e Receivable signals are only from isolated secondary source All interface ports except for Front USB Connector Type A are not intended to be directly connected to a signal source greater than 30 volts and available current greater than SmA lt ANSI ISA 12 12 01 2007 Compliance and Handling Cautions gt e Suitable for use in Class I Division 2
18. unit s operation Only when the FP 3900T series is connected with PS 2000B or PL 3000B Revision B or more FP DV01 100 can be used e Please turn on PS 2000B s internal dipswitch 4 when use FP DV01 100 with PS 2000B The resolution that can be dis played is 1024 x 768 only XGA Please turn off dipswitch 4 when use FP DV01 50 e Please set PL 3000B s internal dipswitch 5 to sign side when you use FP DV01 100 with PL 3000B We will recommend the resolution of PL 3000B to change to the maximum display resolution of FP additionally Please set it on the opposite side of sign when use FP DV01 50 E Serial Interface Baud rate 9600 bps Data length 8 bits RS 232C Serial Interface _ Parity None Stop bit zI Flow Control None Pin Assignments and Signal Names for Serial Interface Pin No Signal Name Condition Pin Location 1 cD Carrier Detect 2 RD Receive Data FP gt Host 3 SD Send Data FP lt Host 4 DTR Data Terminal Ready 5 GND Ground 6 DSR Data Set Ready 9 Request to Send FP lt 4 RS Host Clear to Send FP gt 8 cs Host 9 NC Used internally 1 The CD DTR and DSR are connected together inside of the FP GONMGCION wseceernccsscenerconusi Dsub 9 pin female Connector set screw 4 40 UNC GANG cinsin SIO cable for FP manufactured by Pro face FP61V ISO0 O Concerning Signal Names Signal na
19. upper level Arrow KEY Changes the selection Selects icons or items Saves the current value and quits the OSD Quits the OSD Starting the OSD To start the OSD and enter OSD mode press the three corners of the touch panel in turn upper left upper right and lower right within 5 seconds In OSD mode the setting screen is displayed in the center of the screen In this mode the touch panel cannot be used to export data to external devices unless the settings for the OSD are completed Using the OSD Icons on the screen are used to operate the OSD After the OSD start up the top menu displays Touching the icon you want to adjust displays its submenu or setting change screen In the setting change screen icons are used to change the setting To apply the setting press the Gay button Press the Gy OSD is not displayed when a SW 1 2 is ON button to save the defined settings Quitting the OSD To quit the OSD press the jj or button in the top menu or leave the OSD as it is for at least 30 seconds Mev Inthe OSD pressing the button applies the set value and enables the setting The set value won t be canceled unless the power is turned OFF or the value is reset If the power is turned OFF without saving the set value that data will disappear The last saved data will be read into the system when the FP starts To enable the changed value be sure to press the ET butto
20. z Allowable Voltage Drop T cycle Max Voltage drop interval must be Ts or more 2 AC100V 1 1A or less TYP 0 75A amp Current Consumption AC240V 0 7A or less TYP 0 44A In Rush Current 60A Max AC1500V 20mA for 1 minute between charging and FG terminals DC500V TOMQ Min between charging and FG terminals m Environmental Specification Voltage Endurance Insulation Resistance Item Specification Surrounding Air Temperature 0 50 C The panel should not incline more than 30 Storage Temperature 20 60 C Ambient Humidity 10 90 RH Storage Humidity No condensation Wet bulb temperature 39 C max F i 0 1mg m Max No electrically conductive dust is Air Purity Dust allowed y Pollution Degree For use in Pollution Degree 2 environment m Power Cord Specifications Use copper conductors only Power Cord Diameter 0 75mm to 2 5mm 18AWG to 12 AWG Conductor Type Simple or Twisted Wire 10mm 0 39 in Conductor Length CSSS 1_ If the Conductor s end individual wires are not twisted correctly the end wires may either short against each other or against an electrode m Power connector specification L JAC Input Terminal ive line N IAC Input Terminal neutral line Ground Terminal FG connected to the Fe chassis Kind of power cord is FKC 2 5 3 STF 5 08 which are