Home

NX L24-A - VeranstaltungstechnikMueller

image

Contents

1. equalisation soft limiter compressor and dynamic bass boost The input board presents both XLR jack balanced inputs XLR output link mic line switch volume and a switchable EQ Mode Flat Boost The amplifier features a solid mechanical aluminium structure which not only stabilize the amplifier during transportation but also assist in the heat dissipation ACTIVE TWO WAY ARRAY LEGENDARY RCF TRANSDUCERS DIGITAL AMPLIFIER JACK FEMALE XLR INPUTS BAL UNBAL The system accept jack or XLR input connectors These balanced inputs can be used to connect balanced or unbalanced microphones or audio sources at line level The balanced connector is connected in parallel and can be used to send the audio signal to other amplified speakers recorders or supplementary amplifiers LIMITER LED The amplifier has a built in limiter circuit to prevent clipping of the amplifiers or overdriving the transducers When the soft clipping circuit is active the LED blinks RED It is okay if the limit LED blinks occasionally If the LED blinks frequently or lights continuously turn down the signal level 3 SIGNAL LED The signal indicator lights green if there is signal present on the main input POWER STATUS LED This green led is ON when the speaker is connected to the main power supply and the ON OFF is in ON position MALE XLR SIGNAL OUTPUT The output XLR connector provides a loop trough for speakers daisy chainin
2. or specialised firms who can ensure correct installation and certify it according to the regulations in force The entire audio system must comply with the current standards and regulations regarding electrical systems 9 Supports and trolleys The equipment should be only used on trolleys or supports where necessary that are recommended by the manufacturer The equipment support trolley assembly must be IMPORTANT n moved with extreme caution Sudden stops excessive pushing force and uneven floors may cause the assembly to overturn 10 There are numerous mechanical and electrical factors to be considered when installing a professional audio system in addition to those which are strictly acoustic such as sound pressure angles of coverage frequency response etc 11 Hearing loss Exposure to high sound levels can cause permanent hearing loss The acoustic pressure level that leads to hearing loss is different from person to person and depends on the duration of exposure To prevent potentially dangerous exposure to high levels of acoustic pressure anyone who is exposed to these levels should use adequate protection devices When a transducer capable of producing high sound levels is being used it is therefore necessary to wear ear plugs or protective earphones See the manual technical specifications to know the maximum sound pressure level IMPORTANT NOTES To prevent the occurrence of noise on line signal cables use
3. screened cables only and avoid putting them close to Equipment that produces high intensity electromagnetic fields Power cables Loudspeaker lines OPERATING PRECAUTIONS Place this product far from any heat sources and always ensure an adequate air circulation around it not overload this product for a long time Never force the control elements keys knobs etc Do not use solvents alcohol benzene or other volatile substances for cleaning the external parts of this product IMPORTANT NOTES Before connecting and using this product please read this instruction manual carefully and keep it on hand for future reference The manual is to be considered an integral part of this product and must accompany it when it changes ownership as a reference for correct installation and use as well as for the safety precautions RCF S p A will not assume any responsibility for the incorrect installation and or use of this product WARNING To prevent the risk of fire or electric shock never expose this product to rain or humidity IMPORTANT NOTES OPERATING PRECAUTIONS IMPORTANT NOTES WARNING NX L24 A The concept of this unique active array derives from the touring industry bringing in a compact cabinet all the experience of RCF professional sound The RCF Team always has the performer s needs at the forefront of the design in order to create new lines of speakers with renewed features improved
4. ACKING KIT 2X NXL 24 A L Pole mount accessory for stacking NXL24 on SUB 8004 AS or M20 pole mount l p n 13360280 POLE MOUNT KIT NXL 24 A Pole mount accessory for stacking NXL24 on SUB 8004 AS or M20 pole mount STACKING 2 x NXL 24 A Dual NXL 24 A on a Subwoofer using STACKING KIT 2X NXL 24 A When two NXL 24 A systems are coupled the BOOST setting is recommended INSTALLATION ACCESSORIES INSTALLATION EXAMPLES 2 POLE MOUNTING Single NXL 24 A on a Subwoofer using POLE MOUNT KIT NXL 24 A FLOWN MOUNTING Flown dual NXL 24 A at 0 or at 20 using FLY BAR NX L24 A and FLY LINK KIT NXL 24 A When two NXL 24 A systems are coupled the BOOST setting is recommended ACOUSTICAL Frequency response Max SPL Horizontal Coverage Vertical Coverage Crossover point TRANSDUCERS Low frequency High frequency AMPLIFIER Total power Low section High section CONNECTIONS Signal input output Power input DSP and Protection Circuits PHISICAL SPECIFICATIONS Dimensions w h d Weight Colour SPECIFICATIONS NX L24 A 65 20 kHz 131 dB 120 30 800 4x6 1 5 v c 2 2 5 V C 1400 Watt 1000 Watt 400 Watt Jack XLR male XLR female Powrcon in out 2 way equalisation crossover filtering Fast limiter RMS limiter 1056 201 274 mm 26 4 Kg Black
5. OWNER MANUAL PROFESSIONAL ACTIVE NX L24 A TWO WAY ARRAY NX SERIES LANGUAGE ag ENGLISH ITALIANO 10 SAFETY PRECAUTIONS 1 All the precautions in particular the safety ones must be read with special attention as they provide important information 2 Power supply from mains a The mains voltage is sufficiently high to involve a risk of electrocution install and connect this product before plugging it in b Before powering up make sure that all the connections have been made correctly and the voltage of your mains corresponds to the voltage shown on the rating plate on the unit if not please contact your RCF dealer c The metallic parts of the unit are earthed through the power cable An apparatus with CLASS construction shall be connected to a mains socket outlet with a protective earthing connection d Protect the power cable from damage make sure it is positioned in a way that it cannot be stepped on or crushed by objects e To prevent the risk of electric shock never open this product there are no parts inside that the user needs to access 3 Make sure that no objects or liquids can get into this product as this may cause a short circuit This apparatus shall not be exposed to dripping or splashing No objects filled with liquid such as vases shall be placed on this apparatus No naked sources such as lighted candles should be placed on this apparatus 4 Never attempt to carry out
6. any operations modifications or repairs that are not expressly described in this manual Contact your authorized service centre or qualified personnel should any of the following occur The product does not function or functions in an anomalous way The power cable has been damaged Objects or liquids have got in the unit The product has been subject to a heavy impact If this product is not used for a long period disconnect the power cable 6 If this product begins emitting any strange odours or smoke switch it off immediately and disconnect the power cable 7 Do not connect this product to any equipment or accessories not foreseen For suspended installation only use the dedicated anchoring points and do not try to hang this product by using elements that are unsuitable or not specific for this purpose Also check the suitability of the support surface to which the product is anchored wall ceiling structure etc and the components used for attachment screw anchors screws brackets not supplied by RCF etc which must guarantee the security of the system installation over time also considering for example the mechanical vibrations normally generated by transducers To prevent the risk of falling equipment do not stack multiple units of this product unless this possibility is specified in the user manual 8 RCF S p A strongly recommends this product is only installed by professional qualified installers
7. g VOLUME CONTROL Adjust the amplifier volume This control does not affect the Link Input Link output level SET FLAT OR BOOST EQUALIZATION Boost equalization is a loudness recommended for background music applications when the system plays at a low level or when two systems are coupled For all other applications Flat equalisation is recommended 9 INPUT SENSITIVITY SWITCH Position the switch in LINE to use a line level source 0 dB or MIC to use a microphone source powercon INPUT SOCKET AC POWERCON input connection and output connection FUSE CARRIER Mains fuse housing POWER MAIN SWITCH The power switch turns the AC power ON and OFF The XLR connectors use the following AES standard PIN 1 GROUND SHIELD PIN 2 HOT PIN 3 COLD BAL XLR CONNECTIONS On the back panel you will find all the controls the signal and current inputs In case is necessary to change the voltage please call your vendor or authorized RCF SERVICE CENTRE This operation require the substitution of the fuse value and is reserved to an RCF SERVICE CENTRE At this point you can connect the power supply cable and the signal cable but before turning on the speaker make sure that the volume control is at the minimum level even on the mixer output It is important that the mixer is already ON before turning on the speaker This will avoid damage to the speakers and noisy b
8. sound clarity and definition and even lighter weight systems RCF NXL 24 A represents the latest evolution in the active loudspeaker technology with a revolutionary design and sound Every detail has been carefully studied in order to offer musicians and professionals the perfect tool to amplify their performance night after night High quality materials precise manufacturing careful assembly and extensive quality control procedures complete the groundbreaking design work of the RCF R amp D team The vocals are natural the sound is clear at longer distances the sp power is stable at very high levels The RCF Precision transducers equipping NXL 24 A have been representing for decades the ultimate performance the highest power handling and the most advanced technology in the professional and touring industry The compression driver and woofers are precision built taking advantage of RCF s superior moulding assembly technologies and a wealth of professional knowledge and experience dedicated to achieving extremely high standards The high power woofer delivers extremely accurate punchy bass the custom made compression driver offers a transparent midrange and extreme fidelity RCF Class D power amplifiers technology packs huge performance operating with high efficiency into a lightweight solution NX amplifiers deliver ultra fast attack realistic transient response and impressive audio performance The integrated DSP manages crossover
9. tatus green LED The three types of failure are WARNING a non severe error or auto ripristinate malfunction is detected and the performance of the speaker is not limited LIMITATIONS an error is detected and the performance of the speaker is limited the sound level is reduced by 3 dB This does not affect the operation of the speaker since it continues to operate However it is necessary to call the service centre to solve the issue FAILURE a severe malfunction is detected The speaker switches to mute FLASHING INDICATION 1 or2 gt Warning 3or4 gt Limitation from 5 to 8 gt Failure In case of failure the Ready green LED remains off Perform the checks listed below check if the speaker is properly connected to the power supply make sure that the power supply is of correct voltage check that the amplifier is not overheated disconnect the speaker from the mains power supply wait for a few minutes and connect it again If after these tests the red LIMITER LED is still on please contact an authorised service centre 230 Volt 50 Hz SETUP FUSE VALUE T 3 15 AL 250 V 115 Volt 60 Hz SETUP FUSE VALUE T 6 3 AL 250 V VOLTAGE SETUP RESERVED TO THE RCF SERVICE CENTRE NX L24 A p n 13360278 i FLY BAR NX L24 A rre Sstraight or 2 angles 15 20 p n 13360279 FLY LINK KIT NXL 24 A Accessory to link a second NXL24 to a flying 24 A p n 13360280 ST
10. umps due to turning on parts on the audio chain It is a good practice to always turn on speakers at last and turn them off immediately after the show Now you can turn ON the speaker and adjust the volume control to a proper level The amplifiers are equipped with a microprocessor to control the DSP and the amplifier The correct switch on of the amplifier is ensured by an initialisation procedure during this test stage the LEDs Limiter Signal and Power Status located on the amplifier module remain off for approx 2 sec At the end of the switch on procedure on the amplifier module the Ready green LED only remains steadily on In case of severe failure of the speaker the LED on the front panel flashes several times and on the amplifier module the Limiter red LED flashes The speaker switches to mute BEFORE CONNECTING THE SPEAKER BEFORE TURNING ON THE SPEAKER TURNING ON THE SPEAKER INSTALLATION 7 A 35 mm socket for mounting the loudspeaker on a speaker stand is provided in the bottom of the cabinet NX L24 A speaker MUST be suspended only with approved rigging hardware WARNING Never suspend NX L24 A speaker by there handles Handles are intended for transportation not for rigging WARNING A FAILURE INDICATION AND SAFETY The microprocessor is able to signal three different kinds of failure by flashing the Limiter red LED on the amplifier panel before the lighting up of the Power s

Download Pdf Manuals

image

Related Search

Related Contents

User Manual  x-3 cristalizador - Hiperlimpieza® Venta de productos de limpieza  LokPilot Handbuch A5 V10  Herbicide VENTURE L  Printronix LQH-HWTM Printer User Manual  Connector for Microsoft® Exchange Server  Master Service Manual  Power IQ Benutzerhandbuch – 3.1.1  Manual Garanria - Anemakono.ltd Limited  取扱説明書:PDF 約4.9MB  