1. Bell table times Set Possible error codes 04 07 CRH hhmm A Command Reply Get Possible error codes 04 07 BRR Ahhmmcc Command Reply RR register number in Hex form 02 21H hh hour mm minutes cc checksum The TR515 features a relay that can be used for external bell control Up to 32 different ring times can be specified for which the bell will be activated Each bell table entry consists of two fields time field set through these 32 registers and a corresponding enable disable field set through registers 22H 41H TR515 User s Manual Bell table enable disable Set Possible error codes 04 07 Command CHH SS Reply A Get Possible error codes 04 07 Command BRR ASScc RR register number in the Hex form 22H 41H SS state 00 disabled 01 enabled cc checksum The TR515 features a relay that can be used for external bell control Up to 32 different bell times can be specified for which the bell will be activated Each bell table entry consists of 2 fields time field set through registers 02H 21H and a corresponding enable disable field set through these registers x Example programming a bell table entry for 12 00 00 First set the desired time select a time register that you haven t used yet i e 05H Set the time using the following command C05 1200 Next enable this time through a corresponding enable disable register The corresponding enable disable regist
2. PINS PIN7 PINS PIN1 WAS 1467 LENGH 2000 mm WIRE 8 8 AWG 26 WAS 1467 ePacPN COLOR WRE 1 ow tur 2 ORANGE or 3 BACK cur a Rb cU 6 YELLOW 7 BROWN CUT Cut wire 26 TR515 User s Manual 3 WAS 1498 For TR515EX TO PC PIN1 Side A E PIN1 a I H E PIN8 PIN8 1 2 and 3 6 must share the same twisted pair 4 WAS 1499 For TR515EX TO HUB PIN1 Cr 1 2 and 3 6 must share the same twisted pair 27 TR515 User s Manual Appendix D Specifications Display 4 x T segment Blue Light LED Magnetic card reader ISO Track 2 75 bpi Barcode reader Visible or IR numerical Code39 RFID card reader 125KHz ASK 64bits Manchester encoding RFID reading range ISO card sized tag 8 cm Database capacity App 8200 records Supported interfaces Ethernet Wireless 5 232 RS485 Wireless Communication 315 16 433 92 Mhz or 433 92 434 33Mhz Communications parameters 19200 8 n 1 Bell control relay 1A 12V max Physical dimensions 185 L x 110 W x 51 H mm Installation Wall mount or desktop Power supply DC 9V 500mA Operating temperature range 0 55 Operating humidity 5 95 Requires a spedal adaptor COM485 purchased separately Appendix E Ordering Information Ethernet Interface TR515EM Tim
3. FFH reg data is the data stored in the register checksum This command is used to retrieve the data contained in the designated register Registers are actually functioning parameters settings Complete description of all available registers can be found in Section 4 Get number of records N 4EH Possible error codes 07 N Reply ANNNNcC NNNN number of records in Hex form cc checksum This command can be used to retrieve the number of records currently found in the database Leading zeroes are not omitted so reply string length is always the same TR515 User s Manual Get specified record G 47H Possible error codes 04 06 07 GNNNN ANNNN ccc c E YYYY MM DD hh mm sscc NNNN record number starting from 0000 in Hex form ccc c ID code E event 0 OUT 1 IN YYYY year MM month DD date hh hour mm minute 55 second cc checksum This command is used to retrieve the database record with a specified number Record number must be supplied in Hex format leading zeroes must be preserved or error 04 will be returned Record numbers start from 0000 Specifying record number beyond N 1 where N is the number of records in the database returned by the N command will cause error 06 Returned data string contains the record number ID code of the ID card that was used to create this record event code i e which button was pressed and the date and time of record creation
4. 49H Possible error codes 04 07 Command INN Reply A NN machine number in Hex form 00H FFH 00 should never be used on a multi terminal network because this is a universal number see D command description for details This command is used to assign a new machine number to the terminal Machine numbers provide a way to distinguish between the terminals on a multi terminal network See D command description for more details Get machine number Y 59H Possible error codes 07 Command Heply NN machine number in Hex form 00H FFH This command is used to retrieve the terminal s machine number Machine numbers provide a way to distinguish between the terminals on a multi terminal network See D command description for more details Set date time S 53H Possible error codes 04 07 SYYYYMMDDhhmmss Reply A YYYY year MM month DD date hh hour mm minutes ss seconds This command is used to set the TR515 s internal clock Date time supplied must be valid Incorrect data like 31 of February will be rejected error 04 11 TR515 User s Manual Get date time 54H Possible error codes 07 T Reply AYYYYMMDDhhmmss YYYY year MM month DD date hh hour mm minutes ss seconds This command is used to get the TR515 s current date and time Get firmware version V 56H Possible error codes none Command V Version string length is guaranteed to not exceed 61 character all
5. character codes are guaranteed to be in the 20H 7FH range This command can be used to verify the TR515 s internal firmware version Although version string can be any ASCII string the following format is adopted where VX X is a version number i e V1 0 and is a comment string Comment string is separated from the version number by a single space character Version number will never have any spaces in it Initialize the terminal R 52H Possible error codes none Reply A This command is used to initialize the TR515 Initialization takes place on the next power up not immediately Upon initialization all setting values are restored to their factory defaults TR515 s internal date and time are also checked and if contained garbage initialized to 1999 01 01 and 00 00 00 respectively The database data is not erased this must be done using the E command 12 TR515 User s Manual Set register C 43H Possible error codes 04 07 Command data Reply A RR register number 00H FFH reg data the data for the register to be et n This command is used to set one of the TR515 registers Registers are actually functioning parameters Settings Complete description of all available registers can be found in Section 4 Get register B 42H Possible error codes 04 07 BAR Reply Areg datacc RR register number 00H
6. The TR515 verifies all database records before sending them out to the PC This is done because the FLASH memory may actually contain a garbage data There is a special M command that lets you initialize the database in such a way that it appears to be 100 full you can recover entire database memory contents then Naturally some database records may turn out to contain invalid data Database record validity is verified on a field by field basis Should the field turn out to be invalid its contents are substituted for a safe default data e 10 If ID code turns out to contain illegal characters i e with codes outside of 20H 7FH range then these characters are substituted for If ID code length is outside of valid margins 1 or gt 40 then entire ID code is substituted for the following code 0000000000 ten 0 characters e Date If the date is invalid i e December done then default date 1999 01 01 is used e Time If the time is invalid i e 24 00 00 then default time is used e Event if Event code exceeds 1 then this field is substituted for 0 TR515 User s Manual Initialize the database E 45H Possible error codes none Command E Executing this commands initializes the database This command be used to delete all database data and restore the database functionality in case of database malfunction E command doesn t really delete the data its
7. by the PC This happens when you either set communications parameters of the HyperTerminal incorrectly or if you switch the TR515 on with the IN button pressed before starting the XMODEM on the PC side it should always be the other way around start XMODEM first then switch the TR515 on The timeout error is indicated by a long beep and four dashes displayed by the LED ooo e e Checking existing firmware FMM check To check if the currently downloaded application firmware is valid e Switch the TR515 off e Press and hold both IN and OUT buttons then switch the TR515 back on while keeping both buttons pressed The unit will generate a long beep and display FLCH FLASH check E mt Lt e Memory checkup takes about 5 seconds to complete OUT LED is on while check is in progress Upon test completion the TR515 will either display DONE in case the FLASH memory contains a valid program or Err4 if internal program code is invalid 6 Test mode The TR515 provides a hardware Test mode that can be initiated by issuing a Z command see Section 3 Warning Hardware test destroys the database contents not just deletes it logically so the data cannot be recovered even using the M command The test mode also sets a so called Reset flag the TR515 will be completely reinitialized on the next power up after the test Once initiated the Test mode cannot be exited other than by switching the TR515 off The Test
8. replies All available commands are described later in this Section Of reply codes only two are possible A completed successfully and N Some error was encountered Depending on the command given to the TR515 reply packets with reply code A may contain some data as shown on the Figure above Reply packets with the reply code N always contain a 2 digit error code that can be used to analyze the source of a problem The checksum is an 8 bit sum of all characters between the STX and CR represented as a 2 character HEX string For an example packet below the checksum is calculated as follows The data part of the packet is A1XYZ The sum of these character codes is 41H 31H 58H 59H 5AH 17DH Eight least significant bits contain 7DH The string representation of this value is 7D i e 2 ASCII characters 7 and D CepcL oa rb TR515 User s Manual Table below lists all possible error codes Illegal invalid command command code or data is wrong Record number is out of range requested record doesn t exist Command failed hardware problem or invalid internal data Summarized below are all supported commands Command characters are found in the CC column their corresponding ASCII codes in Hex CS lists commands that require the checksum in the command packet or reply packet R Error code column lists errors that may result from each command exe
9. 168 100 90 0 2 3 4 5 101 Change IP Address Book Add Device Servers DS E found on your local network segment auto discovered by broadcast 2 Click Change IP to change the IP address to be used by TR515 and then click OK P S The IP address must not be the existing one Change IP T IP addxess 192 168 100 TEX EN 29 TR515 User s Manual 3 Skip itby clicking OK Please enter the password for this Device Server Password Remember password omes 4 Select IP Address and Click DS Settings button Properties DS at 192 168 100 232 V2 02L 214 Network Properties Outbound packets Serial Properties Network settings Roung mode SN Device server IP 192 168 100 232 11001 Subnet Mask 0 0 D Router IP Destination IP Transport protocol TCP connection timeout m minutes Password Initialize mu A Select Routing mode Slave B Set IP Address When using multiple TR515E or machines it is recommended to label the IP address on each TR515E or machines C Select Transport P rotocol TCP 30 TR515 User s Manual 5 Enable Allow on the fly serial port parameter changes This helps TR515E to remote control the serial parameters 6 Click OK to finish TCP IP configuration Properties DS at 192 168 100 232 V2 02L 214 Network Properties Outbound packets Serial Properties Seria
10. TR515 Time Recorder V1 00 PROMAG Attention Firmware Management mode FMM The TR515 has two different modes of operation Normal mode provides regular device functionality Firmware Management mode FMM is provided for internal firmware checkup and upgrades see Section 5 The Normal mode is entered by powering the TR515 up while not pressing the IN button Switching the TR515 on while holding the IN button or both IN and OUT buttons down forces the unit into the FMM The FMM mode of operation cannot be exited other than by switching the TR515 off and back on again Attention Firmware Management mode FMM COMETS cutn 1 Installing the TOTO asco oen prre ordo evi dat 1 2 sing ie T35t5 oae o 7 Communications protocol 8 HE 16 5 Firmware Management 20 SPNE I gares 23 Appendix A Possible Errors 25 Appendix B Interface connector pin assignment 25 Appendix 26 Appendix D Specifications 28 Appendix E Ordering Information 28 Appendix F Software Installation 29 TR515 User s Manual 1 Installing the TR515 DC Jac
11. a new firmware file and a terminal software for PC capable of transferring files using Xmodem protocol Checksum version All TR515 firmware files have a fixed size of exactly 64K 65536 bytes The list of popular and widely available terminal programs includes HyperTerminal for Windows QModem and Term95 Procedure below assumes the use of HyperTerminal which is a part of a standard Windows 95 98 distribution To upgrade the TR515 s internal firmware e Switch the TR515 off e sure that the TR515 and the PC are interconnected with a serial cable e Launch HyperTerminal and configure it as follows o When Connection Description dialog opens type any string 1 character minimum and press OK o When Connect to dialog opens select an appropriate COM port from the Connect Using drop down box for example Direct to 20 TR515 User s Manual COM 1 o When Properties dialog appears set communications parameters as follows Bits per second 19200 Data bits 8 Parity None Stop bits 1 Flow control None o HyperTerminal s main window will appear e Choose Transfer Send file from the Main menu the Send file dialog will appear e In the Send file dialog select the file you want to download and choose Xmodem protocol from the Protocol drop down box e The Xmodem file send for dialog will be displayed e Press and hold the IN button then power up the TR515 while still keeping the IN button pressed The unit will gene
12. achine number to the desired value e When the desired machine number is displayed release the OUT button the Terminal will resume normal operation This method allows you to set the numbers in the 0 10 range only which would actually cover most of the actual installation requirements If you need to set the machine number to say 25 then you will have to follow this procedure e Connect the TR515 to the PC using the RS232 cable e Launch the TR515 Control Center software and select the Terminal 5 TR515 User s Manual 0 i e use the universal machine number to address the Terminal e Use the Set button to set the new machine number for this Terminal e Unplug the RS232 cable and put the Terminal back on the RS485 network Note machine number is displayed briefly at the Terminal power up even if you don t push the OUT button Bell relay The TR515 features a built in bell relay The relay is capable of controlling a low power external bell A daily bell schedule of up to 32 different bell times can be defined P cd OOO JI NO COM NC Relay connector is located under the metal back plate Figure above shows connector position and pin assignment Both Normally Closed N C and Normally Opened N O contacts are provided Locking event selection IN or OUT By default the TR515 allows the User to choose the desired event IN or OUT prior to re
13. ading the ID card There is a setting provided that allows event selection to be fixed either at IN or OUT see Section 4 This arrangement may be desirable in case several TR515s are used with some machines installed at the entrance and serving for registering IN events and some machines installed at the exit and serving for OUT registration only Fixing the event prevents the User from choosing an alternative event at the moment of reading ID card TR515 User s Manual 2 Using the TR515 Clocking in and out To register an event IN or OUT push the appropriate button and read your ID card For the TR515R RFID version the card is read by bringing it close to the reader lt 8 cm For the TR515M TR515B and TR515F Magnetic Visible Barcode and IR Barcode respectively the card is read by swiping it in either direction along the reader slot For the machine orientation shown on figure of page 3 magnetic barcode stripe of the ID card must face downwards Note the TR515 can be programmed to fix event selection to IN or OUT only in this case event selection won t work The last four digits of the ID cards ID code are displayed on the LED when the ID card is read Four dashes are displayed in case of read error only applicable to the TR515M e Memory full status When the database memory is full new records cannot be added Reading an ID card will produce a long beep and a FULL message LLL Error cond
14. cution Hid RB c c R 4 6 7 D 44H Select designated terminal Notet T 49H Setnewmachinenumber Get machine number S T 54H Get datetime v R 52H _ 42H Get register see next table N G 45H Initialize the database Z Perform self test Note 1 D command never returns error message even if the data supplied in the command packet is incorrect Invalid command packet makes it impossible to determine which terminal is being addressed and therefore which one should reply with an error code Note 2 Z command is never replied to Follows is the detailed command description Command and reply packets are shown without STX Checksum and CR characters TR515 User s Manual Select designated terminal D 44H Possible error codes none Reply ANN TR515 NN is a machine terminal number in Hex form 00H FFH 00H is a universal number see below for details D is a special command It is used to select a particular TR515 terminal All terminals power up in a deselected state Each terminal ignores all incoming commands until it receives the D command whose machine number is either equal to the machine number of this terminal or 00 After that the terminal switches into selected state and responds to all subsequent commands until new D command with a different machine number is issued Thus the D command should always be used to initiate c
15. e Recorder with Magnetic Card Reader TR515ER Time Recorder with RFID Card Reader TR515EB Time Recorder with Barcode Card Reader visible TR515EF Time Recorder with Barcode Card Reader infrared Wireless Interface TR515WM Time Recorder with Magnetic Card Reader TR515WR Time Recorder with RFID Card Reader TR515WB Time Recorder with Barcode Card Reader visible TR515WF Time Recorder with Barcode Card Reader infrared RS 232 485 Interface TR515SM Time Recorder with Magnetic Card Reader TR515SR Time Recorder with RFID Card Reader TR515SB Time Recorder with Barcode Card Reader visible TR515SF Time Recorder with Barcode Card Reader infrared 28 TR515 User s Manual Appendix F Software Installation Please install DISK5151 Software before using TR515 series DISK5151 includes DS Manager and TR515 Application Program Setting procedure is as follows 1 Ethernet Interface TR515 Hub to TR515E using cable WAS 1499 1 Open the program DS Manager It will automatically detect the IP Address of the TR515 on line The default IP address is 127 0 0 1 For DS Manager cannot detect the IP address in use currently on the LAN please make sure the IP address you set is not in use to avoid duplication Device Server Manager V2 20 Device Servers Local Device Servers auto discovery by broadcast 127 0 0 1 0 2 3 4 37 114 DS 192 168 100 166 0 2 3 4 17 69 EXER 192 169 100 167 0 2 3 4 40 113 t 192
16. efaul to assign the new ID After setting use the new ID to complete the connection a Click Add to increase a new IP Address Ring Table Time Scheduler 001 1 TR amp 15 Firmware Version V1 5 Gom Fort Select 1 z Engi sh EE 166 100 232 Record riage Dete Manual C Always OUT Sat ME Set Time Display Reset C Blas IM TR515 User s Manual b Select 000 default to assign the new ID Assign new ID C Set ID as 001 The correspondent name can be modified at Device Name pstnov2 192 168 100 232 34
17. elf just some internal database housekeeping is initialized The data can still be partially recovered using an M command Prepare for database recovery M 4DH Possible error codes none A 000 O This command alters the database in such a way that it appears to be 10096 full The M command therefore can be used for data recovery purposes For example if E command is executed accidentally while TR515 had some useful data inside then M command can be used to download entire database memory contents Naturally this recovered data may not be consistent Some records may contain garbage data more on this in G command description newer records may overlap older ones etc Perform self test Z 5AH Possible error codes none Command Z Reply This command is never replied to This command is used to force the TR515 into a special Test mode No reply is issued by the TR515 upon receiving this command Details of TR515 s 15 TR515 User s Manual operation in the Test mode are provided in Section 6 Note that Test mode destroys database memory contents in such a way that the data cannot be recovered even with the M command 4 Registers The TR515 features a number of programmable registers Basically registers are the TR515 s functioning parameters Settings Registers can be written to using the C command and read from using the B command see Section 3 for details Table below list
18. er for time register 05H is 25H time registers start from 02H enable disable registers start from 22H we use the 4 register of each group Enable command looks like this C25 01 m vent selection mode register 42 Set Possible error codes 04 07 Command C42 EE Reply A Get Possible error codes 04 07 EE event selection mode 00 free selection by the User 01 fix to OUT 02 fix to IN cc checksum 19 TR515 User s Manual This setting defines if the TR515 will allow the User to choose the event IN or OUT or event selection will be fixed to IN only or OUT only Fixing event may be desirable in case several TR515s are used with some machines installed at the entrance and serving for registering IN events and some machines installed at the exit and serving for OUT registration only 5 Firmware Management mode The TR515 also features new Firmware Management mode FMM FMM allows you to quickly upgrade your TR515 s internal firmware and also check validity of the currently loaded firmware Contact your dealer for the most recent firmware upgrade files FMM itself has two sub modes of operation FMM download mode and FMM check mode FMM download is entered by keeping the IN button pressed while the TR515 is powering up FMM check mode is entered by holding both IN and OUT buttons pressed while the TR515 is powering up Downloading new firmware FMM download To upgrade the firmware you will need
19. itions The TR515 can detect and notify you of a number of different error conditions Please refer to Appendix A for complete list of all possible errors Normal operation of the TR515 is suspended upon encountering an error condition other than card read error New records cannot be added to the database in this situation Communications with the TR515 from the PC side is still possible however This gives you an opportunity to access the TR515 online and attempt to correct the problem TR515 User s Manual 3 Communications protocol The TR515 communications protocol is based on the GNET protocol specification Communications parameters are 19200 8 N 1 Communications between the TR515 and the PC takes place in the form of commands sent by the PC and replies from the TR515 Commands and replies are packets of data Each packet begins with an STX 02H character and ends with CR ODH character Selected commands and replies include a checksum field as an additional safety measure All characters between the STX and the CR characters must be in the 20H 7FH range The STX character of a command packets is followed by a one character command code The STX character of a reply packet is followed by a one character reply code Both command and reply packets may contain some relevant data after the command reply character ct ca or code Data if any Checksum field is not included into certain commands and
20. k Comm Status Bell Control Magnetic barcode Comm Port head on this side Wall mount and desktop operation The TR515 can be used either as a wall mount default see Figure above or desktop device Machine needs to be rotated 180 degrees when used on a desk For this reason the TR515 comes with two different LED plates with their artworks rotated 180 degrees with respect to each other Machine s LED can also display time and other data in a normal wall mount or desktop fashion There is an orientation setting provided that allows you to select display mode see Section 4 1 RS 232 485 Interface Versions The TR515 supports two different interfaces RS232 for single terminal communications and RS485 for multi terminal communications Only one TR515 can be attached to the PC s serial port using the RS232 interface Up to 32 units be interconnected using the multi terminal RS485 communications RS232 arrangement is simple just plug the RS232 cable supplied into the TR515 and connect the other side to the PC s serial port Using RS485 requires a special adaptor CON485 must be purchased separately CON485 is a smart RS232 RS485 converter that allows for higher data transfer rates between the PC and TR515s 1 TR515 User s Manual The RS485 network is of bus type all TR515s are connected in parallel on a so called twisted pair bus The most suitable cable for the bus is the one normally used for Ethe
21. l settings Serial interface Auto x ud Baud rate 19200 bps Parity None Flow control None Data bits 7 Complete the New IP settings of TR515E and click OK to abort Device Server Manager V2 20 Device Servers Local Device Servers auto discovery by broadcast 192 169 100 168 0 2 2 4 23 119 DS Settings 192 168 100 239 0 2 3 4 53 158 Refresh 192 168 100 166 0 2 3 4 17 69 Lema 192 168 100 232 0 2 3 4 37 128 Change IP 192 168 100 167 0 2 3 4 40 113 Address Book Add Device Servers DS E found on your local network segment auto discovered by broadcast 31 TR515 User s Manual 8 Open the Application Program of TR515 Inputthe IP address ofthe on line TR515 and select Com Portas DS100V2 Then double click 000 defaul to complete the connection with TR515 terminal mmTR515 ToolV1 2 R7 001 Default Settings Ring Table Time Scheduler Device List 000 Default 51 5 Firmware Version V1 5 Port Select jp 192 168 100 232 Ds100v2 z English Record mode au Delete Manual C Always OUT C Always IN Set M Set Time Display Reset PC to TR515 using cable WAS 1498 1 Please refer to above procedure 1 7 for settings 2 Open the Application Program of TR515 Inputthe address ofthe on line TR515 and select Port as DS100V2 Then doub
22. le click 000 defaul to complete the connection with TR515 terminal P S The IP address of PC and TR515E must be within one domain to ensure the connection mmTR515 Tool V1 2 R7 001 Default Settings Ring Table Time Scheduler Device List 000 Default Status 51 5 Firmware Version V1 6 Com Port Select p 192 168 100 232 Record mode Delete Manual C Always OUT C Always IN Set M3 Set Time Display Reset 32 TR515 User s Manual 2 Wireless Interface TR515 1 Open the Application Program of TR515 Selectthe Port of the on line TR515 Then double click 000 defaul to complete the connection with TR515 terminal P S Please make sure that the settings of RDL401A 00 are 433 92 MHz 19200 bps mmTR515 ToolV1 2 R7 000 Default Settings Ring Table Time Scheduler Device List FRS15Fimware Version V1 6 Com Port Select cow z English gt ip lu cu zx g Record mode od Delete Manual C Always OUT Set M Set Time Display Reset Always IN Notice for Operation A ID 000 defaul can be set to any TR515 on line However when there are multiple TR515 on line the machine ID cannot be 000 Each TR515 must have its own ID number otherthan 000 B Time Scheduler will not work when the machine ID is 000 It will be enabled when other ID code is selected C Use 000 d
23. mode is comprised of two phases Phase 1 performs automated SRAM RTC real time clock and FLASH memory tests Phase 2 consists of manual button and reader tests 23 TR515 User s Manual Phase 1 begins immediately upon entering the Test mode The LED displays TEST at this time Leon LL Dn A number of errors can occur during this portion of the test All errors are displayed the ERRx format where x is the error number for example LI All possible errors are listed in the table below SRAM test failure RTC test failure FLASH test failure Upon successful completion of the automated tests the TR515 will beep and display b1 5 OUT LED will be switched on EU LZ This means that the manual test phase has commenced This phase consists of three steps OUT button test IN button test and reader test Each step must be repeated five times Press the OUT button and notice that b1 5 changes to b1 4 b1 3 etc When you press the OUT button for the fifth time the display will change to 52 5 and the IN LED will be switched on Press the IN button five times to finish this test step The display reads rd 5 at the beginning of the reader test Read any ID card five times to pass this portion of the test When all manual tests are finished the TR515 will generate a long beep and display PASS od 11 Li This indicates that the test sequence has been completed successfully You can still con
24. n assignment can be found in Appendix TR515 User s Manual 2 Ethernet Interface Versions The TR515EX is designed to attach directly to the RJ45 10BaseT Ethernet connector Standard magnetics circuitry YCL part 20F001N has been included onboard to provide a glueless interface to the Ethernet network Most Ethernet installations require cables of substantial and variable length so you will probably need to make your own cables For testing purposes PROMAG supplies two kinds of Ethernet cables device to hub WAS 1499 for connections through a standard Ethernet hub and device to device WAS 1498 for connections without a hub i e directly from one Ethernet device to another WAS 1498 SS TR515 to HUB TR515 to PC Summary of Status LED signals In the Serial Programming mode Green and Red LEDs are blinking Green Red Green TR515 User s Manual Red Led Green Led 10BaseT Port BELL CONNECTOR TR515 CONNECTOR AND STATUS TR515EX s interface connector pin assignment can be found in Appendix B 3 Wireless Interface Versions The TR515WX designed to operate in the 433MHz ISM Industrial Scientific and Medical frequency band It features Frequency Shift Keying FSK modulation and demodulation capability You must purchase a Master station RDL401A to connect with PC RDL401A Wireless Communication TR515 User s Manual Understa
25. nding machine numbers For single terminal RS232 communications you needn t specify your TR515 s machine number For multi terminal RS485 communications you must make sure that all Terminals on the network have unique machines numbers Machine number is a network address that uniquely identifies the Terminal on the network Having two different Terminals on the network set up to the same machine number will result in the inability to communicate with both Terminals Machine number can be in the 0 to 255 range 00 FF Hex 0 is a universal machine number any Terminal responds to it regardless of this Terminal s actual machine number setting Machine number of 0 can be used for RS232 communications you only have a single Terminal in this case so you can address it with the universal number For multi terminal RS485 communications you ll need to assign a unique and non zero machine number to each Terminal on the network Assigning machine numbers The TR515 offers a fast and convenient way of assigning machine numbers in the range from 0 to 10 To assign a new machine number e Power the Terminal down unplug the power cord e Press and hold the OUT button e Powerthe Terminal up while continuing to hold down the OUT button e After 2 3 seconds the Terminal will beep and display its current machine number for example LI T UL LU e While still keeping the OUT button pressed push the IN button several times if necessary to change the m
26. ommunications between the host and the designated TR515 Note the TR515 never returns any error codes in reply to this command This holds true for both Illegal command error and Command failed error The former is not responded to because when there is some discrepancy in the format of the D command issued by the Host which can only be in the Machine Number field no particular terminal can be sure that it is being addressed Therefore no terminal on the network assumes responsibility for sending a reply Command failed situation can only arise because of incorrect machine number setting value in the TR515 memory In this case the terminal will be unable to compare its internal machine number with the one supplied in the D command Hence the Terminal will not be able to make sure that it is being addressed Since 00 is a universal machine number it works with any terminal Use it only when you have a single terminal connected to the host Universal machine number also comes handy during initial terminal setup to assign a unique machine number to the terminal prior to placing it on a multi terminal network The terminal replies with its actual machine number even if you address it using 00 The only exception is when the terminal is unable to retrieve its own machine number due to some internal malfunction Reply will contain 00 instead of an actual machine number in this case TR515 User s Manual Set new machine number l
27. rate a long beep and display FLLD FLASH Load FL LIE e When receiving the file the TR515 will blink its IN LED the LED is on while the TR515 is receiving or expecting to receive a block of data from the PC the LED is off while the TR515 is programming the data received into its internal FLASH memory e Once the downloading is finished the TR515 will execute one long beep and display DONE Tt Lr LL UL e You may start using the newly downloaded firmware after switching the unit off and back on again A number of errors may occur during the download Errors are displayed in the ERRx format where x is the error number for example LL xL In addition the TR515 generates a beep pattern comprised of a long beep followed by one or several short beeps The number of beeps corresponds to the error number All possible download related error codes are listed in the table below Communications error invalid data received from the PC The most probable cause of this error is incorrect communications parameters you ve set in the HyperTerminal The download file is too big exceeds 64K All TR515 firmware 21 TR515 User s Manual B ada downloading a correct one malfunction The LED display is turned off after displaying the message for some time 22 TR515 User s Manual Finally there is a timeout error that occurs when you start the download but PC doesn t send any data or the TR515 cannot receive the data sent
28. rnet communications twisted pair Cat 111 or V You only need to use one twisted pair of wires inside the cable Note depending on the cable type up to 4 twisted pairs may be available it doesn t matter which one you use just make sure that you are using both wires of the same wire pair To connect the TR515 to the twisted pair bus cut the RS232 cable supplied with each TR515 and locate 2 wires inside Orange and Green Attach each wire to one of the wires on the twisted pair bus Mind the polarity Orange and Green wires cannot be switched It is recommended that you keep the length of each bus stem i e the cable that is used to attach a certain TR515 to the bus as short as possible ideally under 10 cm see the drawing below CON485 485 Green 4 485 Blue 3 One side of the bus must be attached to the CON485 Orange connects to pin 3 Green connects to pin 4 Another side of the twisted pair bus must be properly terminated This is especially important for long buses Standard termination resistor value is 120 Ohm Note It is not always necessary to have the termination resistor It really depends on the actual wiring and connection circumstances Before testing the network make sure that all Terminals and the CON485 are powered and that the CON485 s baudrate selector is in the 19200 position selector must be set prior to powering the CON485 up TR515RX s interface connector pi
29. s all available registers 02H 21H Event selection mode free IN or OUT IN only OUT only LED display mode register 00 Set Possible error codes 04 07 Command Reply Get Possible error codes 04 07 Reply MM display mode 00 wall mount operation 01 desktop operation cc checksum This register is used to set the LED display mode Because TR515 can be used both as a wall mount and as a desktop device the LED data must be displayed in either orientation Setting register to 00 default adjusts LED picture for wall mount operation Setting the register to 01 rotates the image so that it appears correctly when operating as a desktop device Note the mode 16 TR515 User s Manual parameter must be supplied as a 2 digit number i e 00 or 01 Supplying just one digit will generate error 04 TR515 User s Manual Bell duration register 01 Set Possible error codes 04 07 C01 DD A Command Reply Get Possible error codes 04 07 Command B01 ADDcc DD Bell duration in seconds in Hex format OOH FFH cc checksum The TR515 features a relay that can be used for external bell control Bell schedule can be programmed using bell table registers 02H 21H 22H 41H This register specifies the number of seconds the bell will be activated for each time it is enabled Note the DD parameter must always be a 2 digit number i e Supplying just one digit will generate error 04
30. tinue testing the buttons and the reader at this point The TR515 will behave as if in the Normal Mode of operation but no records will be added to the database 24 TR515 User s Manual Appendix A Possible Errors This Section lists all possible error messages that may be generated during the TR515 s normal operation The table below does not apply to the Test and FMM modes of the TR515 see Sections 5 and 6 respectively for complete details on errors generated in these modes LED Eror Description Remedy Read ID card read error Read the card again ee ee ia eee FULL Z7 nee full added issuing the R command Error 5 The database is corrupted First try to power the TR515 off and back on again If this doesn t help initialize the database using the E command or recover the database using the M command Error 6 Time date is not set Use the S command to Ereg correct the problem or reinitialize the TR515 using the R command Appendix B Interface connector pin assignment RUE m ewm 25 TR515 User s Manual 1 WAS 1436 For TR515WX TR515SX RS 232 1 PIN1 PINS WAS 1436 LENGH 2000 mm WIRE 8P8C AWG 28 WAS 1436 DB 9P FEMALE PIN COLOR RJ 11 8P8C PIN GRAY s BACK 3 3 Rb 4 NC GREN 5 y s 6 Nc BROWN 8 NC No Connect 2 WAS 1467 For TR515SX RS 485