1. Pro face migrar Device PLC Connection Manuals About the Device PLC Connection Manuals Prior to reading these manuals and setting up your device be sure to read the Important Prior to reading the Device PLC Connection manual information Also be sure to download the Preface for Trademark Rights List of Units Supported How to Read Manuals and Documentation Conventions PDF file Furthermore be sure to keep all manual related data in a safe easy to find location Chapter 7 Ethernet Connections 7 2 Mitsubishi Electric 7 2 7x9 System Structure This section explains the system structure for the Ethernet connection between a PLC made by Mitsubishi Electric and the GP E MELSEC A Series AJ71E71 A1SJ71E71 using Ethernet Unit Cc o m Ethernet Unit PU A2A A3A A2N AJ71E71 Ethemetcable Digital s GP Ethemet I F A2U S1 conforming to Unit the IE E E 802 3 G P 070 E T11 G P 070 A2US Als 71E71 ET41 si GPTIR Series Muli Unite P GLC Series GP 077 MLTE 11 GP 377R Series M ulti U nit GP 377 MLTE 11 When using GP GLC and extended units refer to Mitsubishi Electric Connectable Devices t For cable connections refer to the user s manual for each optional unit For Note the GP2000 and GLC2000 series however refer to the user s manual for D2 the main unit GP PRO PBIII for Windows Device PLC C
2. 1 J SUBNET MASK Teil Tisch UDP RETRY COUNT 0 255 SEND WAIT TIME 0 to 255 Wait time can be added when a command is transmitted from the GP Use the wait time if the traffic on the communications line is heavy If no wait time is required enter 0 GP PRO PBIII for Windows Device PLC Connection Manual Chapter 7 Ethernet Connections 7 2 Mitsubishi Electric e TIMEOUT 0 to 65535 Enter the desired timeout value If no response is received from the other station within the specified time a timeout occurs If 0 is specified the default time is 15 seconds when it is TCP communication and is 5 seconds when it is UDP communication e IP ROUTE ADDRESS Enter the IP address of the router only one If no router is used enter 0 in all fields e SUBNET MASK Enter subnet masks If no subnet mask is used enter 0 in all fields e UDP RETRY COUNT 0 to 255 Designates the number of times the GP re sends a command when there is no reply from the other port and a timeout occurs When no reply is received after the re try setting number is reached an error message will appear on the GP screen l If the memory is initialized in the OFFLINE mode random val Important ues may be included Be sure to check the displayed values SET UP OPERATION SURROUNDINGS SET UP OPERATION SURROUNDINGS SET CANCEL STARTING ADDRESS OF SYSTEM D
3. fermen comme fe Sc a a a S E LC S o ooo e CT pm J o l e fa C S E a a E e L H Note The range of supported devices may differ depending on your CPU For the D range of supported devices for each CPU refer to the User s Manual for Model AJ71E71 Interface Unit by Mitsubishi Electric 7 2 4 GP PRO PBIII for Windows Device PLC Connection Manual Chapter 7 Ethernet Connections 7 2 Mitsubishi Electric E MELSEC Q MELSEC QnA Series L Setup System Area here eve mes Wowiess Peas mO T E Link Relay B0000 B7FFF B0000 B7FF0 Special Link Relay SB000 SB7FF SB000 SB7F0 Timer contact TS00000 TS23087 Timer Coil TC00000 TC23087 Aggregate Timer lt lt qq900 23087 contact Aggregate Timer coil SC00000 SC 23087 Counter contact CS00000 CS23087 Counter coil CC00000 CC23087 Timer current value TN00000 TN23087 Aggregate Timer SN00000 SN23087 current value x ee a CN00000 CN23087 Data Register ol D00000 D25983 S pecial R egister SD0000 SD2047 W0000 W657F SW000 SW7F F R0000 R32767 n 0R0000 0OR7FFF z O HUER 3 tn z T1 Link Register EN Special Link Register I l aa Oh F ile Register Normal z T z T 1R 0000 1R7FFF File Register Serial 30R 0000 30R7FFF 31R 0000 31R67F F z T1111 GP PRO PBIII for Windows Device PLC Connection Manual 7 2 5 7 2 Mitsubishi Electric Chapter
4. 7 Ethernet Connections Note The device ranges given here show the maximum range available for each V parameter setting When using File Regsters depending on the type of unit used a PLC Memory Card may be required Depending on the size of the Memory Card the de vice ranges will change For details refer to Mitsubishi Electric Co Ltd s User s Manual When using the QnA series unit s File Registers depending on the QnA unit s CPU version certain usage restrictions will apply For details refer to Mitsubishi Electric Co Ltd s User s Manual for QnA Series 7 2 6 GP PRO PBIII for Windows Device PLC Connection Manual Chapter 7 Ethernet Connections 7 2 Mitsubishi Electric y Environment Setup E GP Settings The communications settings for the GP which are required for communica tions via the Ethernet as shown below SET UP OPERATION SURROUNDINGS Menu oO ETUP OPERATION SURROUNDINGS MENU RETURN 1 SETUP OPERATION SURROUNDINGS SETUP ETHERNET NFORMAT ION SETUP ETHERNET EXT INFORMATION SET UP ETHERNET INFORMATION Select SET UP ETHERNET INFORMATION and then enter the necessary information for each item SETUP ETHERNET INFORMATION SRC IP ADDRESS SRC PORT NO DEST IP ADDRESS DEST PORT NO PROTOCOL TYPE SRC IP ADDRESS Enter the IP address for the GP at your station To do this separate the 32 bits of the IP address into fou
5. Unit AJ 71QE71 Ethernetcable Digital s GP AJ 71QE71 B5 conforming to EthernetI F Unit the IEEE802 3 GP070 ET11 GP070 ET41 GP377 MLTE11 GP GLC Series 7 A1S 71QE71 B2 GP377 MLTE41 A1S 71QE71 B5 GP077 MLTE41 When using GP GLC and extended units refer to Mitsubishi Electric Connectable Devices e For cable connections refer to the user s manual for each optional unit For Note the GP2000 and GLC2000 series however refer to the user s manual for x the main unit Connection Structure Up to 8 units GP Series GP Series GP Series MELSEC QnA Series Ethernet Unit Cc O Option Unit Transceiver 4J71QE71 B5 GP070 ET11 A1SJ71QE71 B2 GP070 ET41 A1SJ71QE71 B5 GP377 MLTE11 GP377 MLTE41 GP077 MLTE41 HUB 3 When transmitting data via the PLC s OPEN Setting feature instead of the Auto OPEN UDP Port feature up to 8 GP units can be connected Also when using the PLC s Auto Open UDP Port feature there is no limitationfor for the number of GP units that can be connected 4 When using a LOBASE 5 or a LOBASE 2 cable with the Mitsubishi PLC use a transceiver to connect this cable with the IOBASE T cable GP PRO PBIII for Windows Device PLC Connection Manual 7 2 3 7 2 Mitsubishi Electric Chapter 7 Ethernet Connections IEP Supported Devices The following describes the range of devices supported by the GP E MELSEC A Series J Setup System Area here Ce e e a eee oreo o o o o
6. when Protocol is set to TCP IP 2 Please contact your computer network supervisor to confirm your setting data 3 If OPEN Format is set to Unpassive this item does not need to be set When the Auto Open UDP Port feature is used the Table 3 OPEN Settings are not needed When these settings are used however the PLC s port number is 5000 default setting For details refer to Mitsubishi Electric s Q and QnA Series Ethernet Interface User Manuals MELSEC QnA Series PLC s Ethernet Unit Dipswitch Settings and a Ladder Program are needed to communicate with the GP Ethernet Unit Settings e Operation Mode Setting Switch Contents Operation Mode Settings 7 2 12 GP PRO PBIII for Windows Device PLC Connection Manual Chapter 7 Ethernet Connections 7 2 Mitsubishi Electric e Communication Condition Setting Switch L Recommended Settings Swich Cones Ses o o oo O Action performed when OF F When TCP IP Timeout he PE Timeout SW1 ha Error occurs the line is not TCP IP Timeout occurs Error occurs the line is closed closed SW2 Data Code Settings OFF BINARY Code ON ASCII Code OF F Perform action s defined ON Regardless of 19 afer in Y19 unitis turned ON again or is Reset Initialization is performed Cannotuse fixed to OFF Sw CPU Communication OFF Write in RUN mode is ON Write in RUN mode is Timing Settings l Impossible Possible SWE Inifal Timing Setings OFF Quick Start startwithout ON Normal
7. ATA AREA SYSTEM AREA READING AREA SIZE 0 256 pi DATA CODE BINARY ASCII RESET GP DATA WRITE ERROR ON OFF Lee ee JL es 10 J 20 Jf 30 ff 40 fff 1B ze se ed E E eye e DATA CODE Set only when connecting to a MELSEC Q Series and MELSEC QnA Series This selection controls the type of DATA CODE settings used Select either BINARY or ASCII and confirm that the PLC settings are the same GP PRO PBIII for Windows Device PLC Connection Manual 7 2 9 7 2 Mitsubishi Electric Chapter 7 Ethernet Connections E Sample Ladder Program MELSEC A Series Ethernet interface unit AJ71E71 PLC s Ladder Program is needed to communicate with the GP References For the complete details of settings refer to the user s manual for Model AJ71E71 Ethernet Interface Unit Mitsubishi Elec tric The follwing is a sample ladder lt Sample Ladder gt LD M9038 DMOVP Hxxxxxxxx MOVP KO D102 MOV H0100 D116 MOV K1024 D124 MOV K1024 D127 DMOV Hxxxxxxxx D125 DMOV HFFFFFFFF MOV HFFFF D130 LD M9036 TOP H0000 H0000 LD X0019 MOV K5 D113 TOP H0000 K13 LD M9036 OUT Y0019 LD M9036 OUT Y0008 END D100 IP address of PLC Settings for UDP communications Port number of PLC Port number of GP IP address of GP D100 K50 D113 K1 For the IP addresses check with the network manager xxxxxxxx stands for an IP address in the hexadecimal notation Do not specify any duplicate addresses Be
8. Start Startafter 20 time delay seconds time delay I When performing Write From GP in RUN mode set the CPU Comunication Timing Settings to ON Auto Start Settings Sample Ladder Program This Sample Ladder Program is for communication via the Auto Open UDP Port No default 5000 e PLC IP Address 192 168 0 1 e PLC Port No 5000 When communicating via this function the GP s IP Address and Port No do not need to be set SM402 ON 1 scan after RUN finihes Initial Comand H i PLS MO Initial Trigger Transact MO X1F DT Error Detection DMO VP HCOA80001 D1000 PLC s IP Address DTO HO HO D1000 K1 Copy to Buffer Memory SET 19 Initial Request END The sample ladder above is the minimum ladder to commu nicate with GP via UDP IP For details about error pro cessing and TCP IP communication refer to Mitsubishi Elec tric Co Ltd s User s manual for QnA Series Ethernet In terface Unit Detail manual GP PRO PBIII for Windows Device PLC Connection Manual 7 2 13 7 2 Mitsubishi Electric Chapter 7 Ethernet Connections EP ErrorCode S About the GP Ethernet Speicific Error Codes refer to the end of this Chapter Protocol Stack Error Codes BPLC SPECIFIC ERROR CODES PLC error codes are displayed by the Host Communication Error 02 and indicated in the left lower corner of the GP screen indicates the PLC s specific error codes Error Code Description
9. onnection Manual 7 2 1 7 2 Mitsubishi Electric Chapter 7 Ethernet Connections E MELSEC Q Series Q 71E71 Ethernetcable Digital QJ 71E71 B2 conforming to Ethernetl F Unit the IEEE802 3 GP070 ET11 GP070 ET41 GP GLC Series GP377 MLTE11 GP377 MLTE41 GP077 MLTE41 1 When using GP GLC and extended units refer to Mitsubishi Electric Connectable Devices For cable connections refer to the user s manual for each optional unit For Note the GP2000 and GLC2000 series however refer to the user s manual for x the main unit Connction Structure Up to 16 units ____ oO o o Option Unit GP070 ET11 GP070 ET41 GP377 MLTE11 GP377 MLTE41 GP077 MLTE41 HUB 10BASE T Cable Ethernet Unit QJ71E71 QJ71E71 B2 ransceiver t 3 When transmitting data via the PLC s OPEN Setting feature instead of the Auto OPEN UDP Port feature up to 16 GP units can be connected Also when using the PLC s Auto Open UDP Port feature there is no limitationfor for the number of GP units that can be connected 4 When using a L OBASE 5 or a 10BASE 2 cable with the Mitsubishi PLC use a transceiver to connect this cable with the I OBASE T cable 7 2 2 GP PRO PBIII for Windows Device PLC Connection Manual Chapter 7 Ethernet Connections 7 2 Mitsubishi Electric E MELSEC QnA Series LinkI F Cable Diagram Cables Unit GP GLC Ethernet
10. r segments of eight bits each delimit those segments with a dot and then enter them as decimal numbers SRC PORT NO Enter your station port number in the range from 1024 to 65535 DEST IP ADDRESS Enter the IP address of the other station the MELSEC GP PRO PBIII for Windows Device PLC Connection Manual 7 2 7 7 2 Mitsubishi Electric Chapter 7 Ethernet Connections 7 2 8 DEST PORT NO Enter the port number of the other station in the range from 1024 to 65535 PROTOCOL TYPE You can select either UDP or TCP communication If the power will be turned ON OFF synchronously it is recommended that you use UDP communica tions For the IP addresses check with the network manager Do not specify any duplicate IP address When using the built in Ethernet port on a GP2000 or GLC2000 Important series unit be sure not to set any duplicate SRC PORT No values Check the 2 way driver s SRC PORT No setting via the fol lowing menu GP OFFLINE mode s Main menu INITIALIZE gt SETUP OPERA TION SURROUNDINGS gt EXTENDED SETTINGS gt SETUP ETHERNET INFORMATION The default value is 8000 The 2 way driver uses this port and the following 9 ports 8000 8009 Be sure not to use Port No s 5001 and 5002 since they are used by the PLC s Ethernet Unit SET UP NETWORK EXT INFORMATION SETUP NETWORK EXT INFORMATION SET CANCEL SEND WAIT TIME ms TIMEOUT x 2sec IP ROUTER ADDRESS l1
11. ss Status 0055 Write error in RUN mode Write in RUN mode is setto OFF 4031 CPU Device Settings Error Designated device is outside allowable range MOAIS For more details about error codes refer to Mitsubishi Elec tric Co Ltd s User s Manuals for Q Series Ethernet Inter face Unit and QnA Series Ethernet Interface Unit 7 2 14 GP PRO PBIII for Windows Device PLC Connection Manual
12. sure that any addresses D used in the communications Important Settings for the PLC are not the same as the first address of the system on the GP 7 2 10 GP PRO PBIII for Windows Device PLC Connection Manual Chapter 7 Ethernet Connections 7 2 Mitsubishi Electric MELSEC Q Series Prior to GP starting GP communciation the MNET 10H Ethernet settings must be set in the PLC s ladder logic software The setting values are as shown below 1 Network Parameter MNET 10H Ethernet Settings 2 Ethernet Operation Settings 3 OPEN Settings 1 Network Parameter MNET 10H Ethernet Settings PLC Settings This setting does not effect PLC GP communication 2 Ethernet Operation Settings _ Recommended Settings fons ngs Any number Write Possible in RUN mode Please contact your computer network supervisor to confirm your setting data 2 When performing Write from a GP in RUN mode set the Write Possible in RUN mode to Allowed GP PRO PBIII for Windows Device PLC Connection Manual 7 2 11 7 2 Mitsubishi Electric Chapter 7 Ethernet Connections 3 OPEN Settings items PLC Settings Remarks Protocol TCP IP UDP IP Should be same as GP units Communcation F ormat Settings PEA Tema Fullpassive es or Unpassive can 0 Should be same as GP units DEST 23 Should be same as GP units SRC DEST PortAddress kamas Should be same as GP units SRC y PortNo Subscription Can be used only