Contents

1. STORE CONDITIONS Store the UPS covered and upright in a cool dry location with its battery fully charged the ups for at least 4 hours Remove any accessories in the accessory slot and disconnect any cables connected to the computer interface port to avoid Unnecessary draining the battery 9 2 EXTENDED STORAGE During extended storage in environments where the ambient temperature is 15 to 30 charge the ups s battery every 6 months During extended storage in environments where the ambient temperature is 15 to 45 charge the ups s battery every 3 mon ths INPUT Power rating 1000VA 2000VA 3000VA Voltage 220V 25 Frequency 50 or 60Hz _ 5 OUTPUT Voltage 220V 5 Frequency 50 True 60Hz 0 5 Voltage The AVR increase automaticly output voltage 15 if the mains voltage falls down 9 or regulation 25 AVR The AVR decrease automaticly output voltage 13 if the mains voltage increase 9 or 25 Transfer time 2 4 ms PROTECTION Lightning 320 joule 2ms AND Protection FILTERING Overload The UPS shout down automaticly if the load current exceeds 110 for 30 seconds or 130 for 3 Protection seconds Input Fuse agaist overload and short circuit Short circuit Automatic shout down of the output and input fuse protection BATTERY Type Informer 1000 Maintenancefree 2 12Ah External Battery Cabinet 6 12Ah Informer 2000 Maintenancefree 4 7Ah External Batte
2. battery to avoid short circuit 3 5 INPUT VOLTAGE HIGH indicator AVR Automatic Voltage Regulation is on YELLOW LED The LED illuminates when the input voltage is high and regulated the voltage supplied to the load by UPS 3 6 LINE NORMAL indicator GREEN LED The LED illuminates when the input is normal 3 7 INPUT VOLTAGE LOW indicator AVR Automatic Voltage Regulation is on YELLOW LED The LED illuminates when the input voltage is low and regulated the voltage supplied to the load by UPS 3 8 LOAD LEVEL indicators The LEDs illuminates depending on the load level 3 9 BATTERY LEVEL indicators The LEDs illuminates depending on the battery capacity 3 10 OFF button Press the button to turn off the UPS BACK PANEL 31 4 o Te ONO ULM Sogn Oi TOTT 313 BATTERY SOCKET O a 4 INSTALLATION 4 1 INSPECTION Inspect the UPS upon receipt 4 2 PLACEMENT Install the UPS in a protected area with adequate airflow and free of excessive dust Do not operate the UPS where the temperature and humidity is outside the specified limits 4 3 CHARGE THE BATTERY The UPS charges its battery whenever it is connected to utility power For best results charge the battery for 4 hours in the initial use 4 4 CONNECT THE LOADS Plug the loads into the output connectors on the rear of the UPS To use the UPS as a master on off switch be sure all of the loads are switched on Caution Avoid connecting a laser
3. printer or plotter to the UPS with other computer equipment A laser printer or plotter periodically draws significantly more power than when idle and may overload the UPS 5 OPERATION 5 mb SWITCH ON With the UPS plugged in press and hold the ON TEST button more than 1 second until LINE NORMAL LED lit to switch the UPS on The UPS perform self testing each time when it is switched on 5 2 SWITCH OFF Press the OFF button more than 3 seconds until the LINE NORMAL LED and BACK UP LED off 5 3 SELF TEST Use the self test to verify both the operation of the UPS and the condition of the battery In normal utility power press the ON TEST button less than 1 second and UPS performs a self test function 6 ALARMS 6 1 BACK UP When BACK UP mode the YELLOW LED illuminates The alarm stops when the UPS returns to LINE NORMAL operation 6 2 LOW BATTERY In BACK UP mode when the battery energy runs low the LED illuminates until the UPS shuts down from battery exhaustion or returns to LINE NORMAL operation 6 3 OVERLOAD When the Ups is overloaded the connected loads exceed the maximum rated capacity the UPS emits continuous alarm to warn an overload condition Disconnect nonessential load equipment from UPS to eliminate the overload 6 4 BATTERY REPLACEMENT When the batteries not pass the SELFTEST UPS give continuous alarm and REPLACE BATTERY LED illuminates To replace the battery inform the authorized technical servi
4. XK mform INFORMER SERIES Uninterruptible Power System Line Interactive UPS 1000VA 2000VA 3000VA USER MANUAL 1 PREFACE The product is line interactive UPS with the newest technology and powerful function The LINE INTERACTIVE UPS is with AVR function allows input voltage range from 75 to 125 including on line voltage boost up buck down Ideal protection equipment for critical connected loads 2 SAFETY WARNINGS For the user own safety The safety of data and this product read the following safety instructions carefully before using the UPS system This system has been designed to provide all the necessary safety conditions needed to protect electronic office equipment including information systems In case of any questions refer to your authorised technical service representative In order to avoid any damage to the equipment it is advised to transport it in own packing Battery s energy cannot be cut by the user For to get energy from the output the unit should be separated from the mains In the case of urgency the best way of the cut the Uninterruptible Power Supply is to take the button from to OFF then take off the power supply from the mains Please avoid batteries from the fire It is flammable Do not open or mutilate the battery released electrolyte is harmful to the skin and eyes It may be toxic A battery can present a risk of electric shock and high short circuit current The foll
5. ce or see Part 9 7 8 9 1 MAINTENANCE e Please keep clean the UPS and clean with vacuum periodically eClean with soft and not humidity ePlease check the connections monthly Please protect from the rain sunshine and humidity ePlease keep away from the fire eDo not put anything on the UPS ePlease make it work 0 40C BATTERY CHARGE UPS can work 3 5years without change the battery Please follow the instructions below for easy battery replacement e Unplug unit from AC power source and disconnect all connected equipment e Disconnect AC power cord from unit e Please take off the screws from the right side of the UPS e Carefully lift top cover off and place to side Be careful do not touch any inner components when changing the battery e Remove the 2 connecting wires from the battery e You can easily remove the battery from the unit Caution Do not dispose of battery in fire Caution Do not attempt open the batteries Attention the following precautions should be taken when replacing the batteries Remove watches rings and etc Use tools with insulated glove e Put the new battery into place of the old battery in the same position e Attach the red cable into positive attach the black cable into negative through the battery eFor to assemble of the UPS again you must follow step by step 5 4 3 e For the installation of the UPS you must follow the directions which belongs to the guidebook STORE
6. owing precaution should be observed when working on batteries Remove watches rings or other metal objects Use tools with insulated handles Wear rubber gloves and boots Do not lay tools or metal parts on top of batteries Disconnect charging source prior to connecting or disconnecting battery terminals CAUTION caritas Risk of electric shock do not remove cover No user serviceable parts inside Refer servicing to qualified service personnel WARNING To reduce the risk of fire replace only with the same type rating of fuse WARNING To reduce the risk of fire or electric shock install in temperature and humidity controlled indoor area of conductive contaminants 3 INTRODUCTION FRONT PANEL Q 4 informerA 000 Uninterruptible Power Supply 3 1 ON TEST Button Press the button more than 3 seconds to turn the UPS on or press the button less than 1 second to activate the UPS s self testing 3 2 OVERLOAD indicator RED LED The LED illuminates when the loads are over the capacity of UPS 3 3 BACK UP indicator GREEN LED The LED illuminates when the UPS is supplying battery power to the loads 3 4 REPLACE BATTERY indicator RED LED The LED illuminates when the UPS s battery is no longer useful and must be replaced Note When battery replace disconnect the utility power then open the case and take notice of the battery s polarity while install the new
7. ry Cabinet 12 7Ah Informer 3000 Maintenancefree 4 7Ah External Battery Cabinet 12 7Ah Typical 4 hours 90 of the full capacity Charging time Protection Automatic self test amp descharge protection Replace the battery indication Back up time 8min 100 1 hour 63min 100 5 5 hour Dependence to the load Netto weight Informer 1000 19 kg External Battery Cabinet 22 kg Kg Informer 2000 31 kg External Battery Cabinet 37 kg Informer 3000 32 kg External Battery Cabinet 37 kg PHYSICAL Dimensions Informer 1000 135x430x390 mm SPECIFICATION Informer 2000 3000 135x470x390 mm ENVIRONMENT Acoustical lt 40dBA 1m far from the UPS noise