1. TERMINAL RED BLOCK YELLOW 2 IF ONE SHELF IS UNPLUGGED THE CAP HAS TO BE IN PLACE FOR THE OTHER LAMPS TO WORK ON THAT BALLAST DUE TO THE ANTI ARC PLUG THE NUMBER OF LIGHTS FANS AND ANTI SWEAT HEATERS ARE DETERMINED BY CASE SIZE AND STYLE CONTROLS CONDENSATION PUMPS AND OUTLETS ARE OPTIONAL EACH OUTLET IS WIRED TO A SEPARATE JUNCTION BOX QAElectricalWiring Diagrams WIRING DIAGRAMS 2014 dwg June 10 2015 10 49am Printed By cwalker TERMINAL BLOCK DETAIL ION APPROVAL 208 230 VOLT SELF CONTAINED CASE SOUTHERN STORE FIXTURES INC ALL RIGHTS RESERVED FABRICAT BY COPYRIGHT 2006 STORE FIXTURES INC 275 DREXEL ROAD SE Drawn By C SALTER 12 30 09 1 1 0 THIS DRAWING IS THE PROPERTY OF SOUTHERN STORE FIXTURES INC AND IS NOT TO BE REPRODUCED OR EXCHANGED WITH ANY OTHER PERSON OR COMPANY WITHOUT THE EXPRESS WRITTEN CONSENT OF SOUTHERN STORE FIXTURES INC BESSEMER AL 35022 205 428 4800 phone 205 428 7788 fax Page 13 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Factory Settings REFRIGERATION DATA THESE SETTING ARE SUBJECT TO CHANGE WITHOUT NOTICE mo zr s r 47 30MIN 4 70 24 2r 57 4 M ox sr 4 0 2 2r 57 40
2. 18 Default Control Settings 19 4 Optional Equipment 5 Condensate Pumps 20 21 6 7 Air Flow amp Product Loading 8 General Information amp Diagram 22 8 8 Maintenance amp Care Information 8 9 General Care and 1 23 9 Exterior Surfaces 23 9 Interior Surfaces 23 10 Case Cleaning amp Maintenance 23 10 Cleaning Honeycomb Assembly 23 Cleaning Plexiglass 23 Maintenance Schedule 24 25 Service 11 13 Trouble Shooting Guide ________ 26 27 Service Department 28 28 T Maintenance Records 29 30 14 Limited Warranty amp Compliance 14 Limited Warranty Information 31 14 Liabilty Notice a an 32 O Important Reminder Keep This Guide For SOUTHERN Future Reference CaseArts 275 Drexel Road S E Bessemer AL 35022 Phone 800 552 6283 Fax 205 428 2552 southerncasearts com Page 1 Case Diagrams amp Mechanicals FLX 01 FLX 01N Narrow OPTIONAL 12 SHELF SECTION VIEW FLX 01 01N SECTION VIEW FLX EC SECTION VIEW FLX 03 SECTION VIEW FLX PX
3. Section Views Page 2 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Case Diagrams amp Mechanicals 1 1 4 PER 4 6 8 10 OR 12 END PANEL 47 FLX 01 40 FLX 01N PLAN VIEW n 965 1 1 4 TYP PER END PANEL PLAN VIEW FLX EC 1 1 4 TYP PER END PANEL 4 6 8 10 OR 12 PLAN VIEW FLX 03 1 1 4 TYP PER _ END PANEL 4 6 8 10 OR 12 PLAN VIEW FLX PX Plan Views 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Page 3 General Information Receiving Cases Transportation companies assume all liability from the time a shipment is received by them until the time it is delivered to the consumer Southern CaseArts Inc liability ceases at the time of shipment All equipment should be thoroughly examined for shipping damage and or shortages before and during unloading This equipment has been carefully inspected at our factory Any claim for loss or damage must be made to the carrier The carrier will provide any necessary inspection reports and or claim forms For information on shortages please contact the service parts department at 800 552 6283 Apparent Loss or Damage If there is an obvious loss or damage it must be 1 noted on either the freight bill or the express receipt and 2 signed by
4. sr 4 WILL CHANGE DEPENDING ON LIGHTS ANTI SWEATS AND APPLICATION THESE ARE FOR A PRODUCE APPLICATION ELECTRICAL DATA 115 VOLT REMOTE monet uemss Fansa curse Fansa pass wa ox wa o _ rxo os os 06 osa osa o wa osa _ NA NA NA move uemse Fanse ransa 10 _ N A N A wa 10 _ mo io os 138 oe 207 102 10 _ oe ee LIGHT AMPERAGES MAY VARY DEPENDING ON AVAILABLE OPTIONS Page 14 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Mechanical Expansion Valve and Superheat During service of this equipment precautions should be taken to prevent loss of refrigerant to the atomosphere Always install the expansion valve stem cap after making valve adjust ments Setting Superheat The expansion valve furnished with your case has been sized for for maximum coil efficiency To adjust superheat perform the following 1 Place a thermocouple near the expansion valve bulb Read the suction line pressure as near coil as possible If closest is at the condenising unit estimate suction line loss at 2 PSIG 2 Convert coil suction pressure to temperature The difference between coil temperature and the temperature is superheat Use average superheat when expan
5. PS vlr uno LL ES h ww L ORGAN i EZ EE ies Installation Maintenance amp Operation Guide 700 SERIES FLX 01 FDC O1N FLX EC FLX 03 FLX PX Refrigerated Produce Merchandisers 800 552 6283 southerncasearts com General Information Case Diagrams amp Mechanicals Receiving Cases Apparent Loss or Damage Concealed Loss or Damage Exterior Loading Handling of Cases Store Conditions Installation Instructions Locate Area of Placement Marking Area on Floor Leveling Roll Case into Place Join CASES Bolt Cases Together Case Mechanical Connections ____ Shelving Electrical Information Wiring Diagrams 2 Refrigeration Information Superheat Settings BTU Defrost 5 Electrical Ratings 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Table of Contents Control Information 2 3 General Information 16 4 Diagrams 17 4 Parameter Information
6. 162 1 6 disable decimal point 0 1 7 enable probe 2 alarm model M only t 0 0 C1 probe 1 offset F 127 4127 0 C2 probe 2 offset F 12 7 4127 CC PF 0 C3 probe 3 offset F 127 4127 CC F 0 5 set point 5 ri r2 r minimum set point value C 50 r2 20 r2 maximum set point value C rl 150 60 r3 select direct reverse operation C 0 0 r4 night time set point delta C 50 50 0 rd control differential F 0 419 C F 4 c0 compressor and fan start delay on power up C 0 00 min 0 C minimum time between consecutive compressor starts C 0 100 min 0 c2 minimum compressor off time C 0 100 min 0 c3 minimum compressor on time C 0 00 min 0 c4 compressor on time with duty setting 0 00 min 0 continuous cycle duration 0 5 h 4 temperature alarm bypass after continuous cycle 0 5 h 2 do type of defrost 0 4 0 interval between defrosts F 0 99 h min see dC 4 6 4 3 dt end defrost temperature set point defrost temperature F 50 127 47 47 50 50 threshold with temp control dP maximum defrost duration 1 99 min s see dC 40 d4 defrost when switching the instrument on 0 1 0 d5 defrost delay on power up or when enabled by digital input C 0 99 min 0 d6 freeze control temperature display during defrost 0 0 dripping time F 0 5 min d8 alarm bypass time after defrost F 0 5 h d9 defrost priority over compressor protectors C 0 1 0 d defrost probe reading
7. use or revenue or additional labor cost loss of refrigerant or food products or injury to person s or property caused by or resulting from any defective products material or parts or for any delay in its performance hereunder due to causes beyond its control This warranty is expressly in lieu of all other warranties express or implied and all other obligations or liabilities on Southern CaseArts Inc s part The obligation to repair or replace parts or components determined to be defective in material or workmanship shall be Southern CaseArts Inc s only and entire liability whether based on tort contract warranty or any other theory Southern CaseArts Inc neither assumes nor authorizes any other person or entity to assume for it any other liability in connection with any product s The foregoing shall constitute the sole and exclusive liability of Southern CaseArts Inc Customer s acceptance and or use of any Southern CaseArts Inc product s constitutes customer s acceptance of and agreement with all terms and provisions of this limited warranty MAIL CLAIM TO SOUTHERN CASEARTS INC 275 DREXEL ROAD S E BESSEMER AL 35022 2013 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Page 31 Liabilty Notice Shelf Lighting System Southern CaseArts inc will not be liable for any direct or indirect exposure to water or other liquids on the shelf lighting system The use of a water hose or misti
8. 31415 Lie PJEZM P 0 PJEZM P 1 NTC PROBES 41516 PJEZM P E iu 4 User Interface and Startup 4 1 Display Fig normal operation start no ON OFF flash Jup 1 compressor off call ON 2 fan on off call ON 3 defrost on off call ON 4 m T output active output not active ON RTC not available an if 5 clock RTC and at least one clock time band has is been set time band set fitted no alarm in 6 alarm alarm in progress progress ON three digits with decimal point and range 199 to 7 digits 999 See parameters 4 5 6 for the type of probe displayed values in decimal point but no function normal operation start up ON OFF flash 1 compressor off call ON two digits with sign and decimal point 99 to 99 2 digits See parameters 4 5 6 for the type of probe displayed values in C F and decimal point 4 2 Keypad Functions Keypad functions for easy and easy compact models C S X Y no normal operation start up pressing the button pressing with other alone buttons pressed together 5 1 more than 3 5 switch with 3 activates ON OFF deactivates the continuous cycle 1 s displays sets the foris ressed together set point RESET p and 3 activate more than 3 s current EZY parameter rese
9. PRODUCTS ARE WARRANTED TO BE FREE FROM DEFECTS IN MATERIAL AND WORKMANSHIP UNDER NORMAL USE AND MAINTENANCE FOR A PERIOD OF TWELVE MONTHS FROM THE DATE OF ORIGINAL SHIPMENT A NEW OR REBUILT PART TO REPLACE ANY DEFECTIVE PART WILL BE PROVIDED WITHOUT CHARGE PROVIDED THE DEFECTIVE PART IS RETURNED TO SOUTHERN CASEARTS INC THE REPLACEMENT PART ASSUMES THE UNUSED PORTION OF THE WARRANTY This warranty does not include labor or other costs incurred for repairing removing installing shipping servicing or handling of either defective parts or replacement parts The twelve month warranty shall not apply to any of the following 1 To any product or any part thereof which has been subject to accident alteration negligence misuse or abuse operation on improper voltage or which has not been operated or maintained in accordance with the Southern CaseArts Inc s recommendations or if the serial number of the unit has been altered defaced or removed 2 When the product or any part thereof is damaged by fire flood or other act of God 3 Outside the continental United States 4 To labor cost for replacement of parts or for freight shipping expenses sales tax or upgrading 5 When the operation is impaired due to improper installation THIS PLAN DOES NOT COVER CONSEQUENTIAL DAMAGES Southern CaseArts Inc shall not be liable under any circumstances for any consequential damages of any kind including without limitation loss of profit
10. SOLENOID CIRCUIT INTERRUPTER PLUG FAN BOX 4L T 5 BALLAST BLUE RED YELLOW iE etAcK CIRCUIT INTERRUPTER PLUG MM DD YY THIS DRAWING IS THE PROPERTY OF SOUTHERN STORE FIXTURES INC AND IS NOT TO BE REPRODUCED OR APPROVAL DATE 3 LIGHTS BOX _ 3 BLUE RED YELLOW VARIABLE CIRCUIT INTERI VOLTAGE CONTROL ra 5 5 RED YELLOW CIRCUIT INTERRUPTER PLUG Qe Le 2L T 5 BALLAST RED YELLOW ANTI SWEAT IF ONE SHELF IS UNPLUGGED THE CAP HEATERS HAS TO BE IN PLACE FOR THE OTHER LAMPS TO WORK ON THAT BALLAST DUE TO THE ANTI ARCH PLUG WITHOUT THE EXPRESS WRITTEN CONSENT OF SOUTHERN EXCHANGED WITH ANY OTHER PERSON OR COMPANY STORE FIXTURES INC SOUTHERN STORE FIXTURES INC ALL RIGHTS RESERVED FABRICATION COPYRIGHT 2006 Kl 2 K 2 K Xi K 2 Kl 2 K Xi Kl Ri K 2 K R Kl 2 Kl 2 S 4 205 428 4800 phone 205 428 7788 fax STORE FIXTURES INC 275 DREXEL ROAD SE BESSEMER AL 35022 THE NUMBER OF LIGHTS FANS AND ANTI SWEAT HEATERS ARE DETERMINED BY CASE SIZE AND STYLE CONTROLS CONDENSATION PUMPS AND OUTLETS ARE OPTIONAL EACH OUTLET IS WIRED TO A C SAL
11. The air intake grill has an air filter that needs to be cleaned monthly or more frequently if required For cases equipped with an electric condensate dissipater pan Electric dissipater pans are meant solely for the purpose of evaporating condensate water released from the refrigeration coil during the defrost cycle Dust food products grease caustic liquids flammable materials wash water and or cleaning chemicals should not be allowed to accumulate in the pan Regular monthly maintenance should be performed to make sure the pan is clean and the float switch moves up and down freely Failure to follow these guidelines could result in flooding overheating and or a fire hazard all of which will void the warranty These cases require a dedicated circuit with proper sized wire for the distance from the electric panel Cases equipped with electric dissipater pans should never have food products washed or poured into the case tub drain as it will result in damage to the heating element DO NOT WASH OUT THE CASE WITH CAUSTIC CHEMICALS unless the case is attached to a floor drain Many cleaning chemicals will dissolve the heater elements in the electric evaporator pans Southern CaseArts refrigerated standard display cases are designed for use air conditioned stores where the temperature and relative humidity do not exceed 75 F and 55 RH When utilizing refrigerated self service or open case merchandising the following should be considered
12. a spotter to guide forks into place to refrigeration lines prevent damage to electrical plumbing and refrigeration lines DO NOT PUSH OR PULL ON ANY GLASS COMPONENTS OF THE CASE Glass breakage may result in serious injury Page 6 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Installation Instructions WARNING Do not place self contained version of this unit equipped with an electric evaporator pan near or under any flammable structure or flammable merchandise This could result in a fire hazard Do NOT walk on top of the case These cases are not designed or built in standard models to support extra weight on top Heavy weight placed on top of the case may cause damage to the case as well as personal injury IMPORTANT IT IS THE INSTALLERS RESPONSIBILITY TO INSTALL CASE TO MEET ALL LOCAL BUILDING AND HEALTH CODES IMPORTANT BEFORE STARTING THE UP THE CASE CHECK ALL ELECTRICAL CONNECTIONS 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Southern CaseArts refrigerated standard dis play cases are designed for use in air condi tioned stores where the temperature does not exceed 75 F and the relative humidity does not exceed 55 Air conditioning fans ovens spot lights direct sunlight or anything that could disturb the air flow inside the case could result in poor perfor mance DO NOT WALK
13. as these will mar the finish DO NOT use solvent oil or acidic based cleaners on any interior surfaces Remove all product and all loose debris to avoid clogging the waste outlet Next turn off refrigeration then disconnect electrical power Thoroughly clean all surfaces with soap hot water and a cleaning cloth or sponge DO NOT USE STEAM OR HIGH WATER PRESSURE HOSES TO WASH THE INTERIOR THESE WILL DESTROY THE CASES SEALING CAUSING LEAKS AND POOR PERFORMANCE Take care to minimize direct contact between fan motors and cleaning or rinse water Rinse with hot water and a cleaning cloth or sponge but do NOT flood NEVER INTRODUCE WATER TO SELF CONTAINED CASES CASES WITH EVAPORATOR PAN OR CONDENSATE PUMP OR FASTER THAN THE DRAIN OUTLET CAN REMOVE IT Allow cases to dry before resuming operation Then power can be restored to case Do NOT use hot water on cold glass surfaces This could cause the glass to shatterand could result in personal injury Glass fronts and ends should be warm before applying hot water Cleaning Honeycomb Assembly Honeycombs should be cleaned when necessary Dirty honeycombs will cause merchandisers to perform poorly The honeycombs may be cleaned with a vacuum cleaner Soap and water may be used if all water is removed from the honeycomb cells before replacing Be careful not to damage the honeycombs Plexiglass Cleaning It is very important to utilize only the recommended method and products for cleaning plexig
14. voltages lower than rated supply can reduce perfor mance and cause the pump to overheat Pump Installation The pump must be level and should be placed on a solid surface or floor The pump has rubber feet to reduce noise and keep it in place during operation Do not use this pump in the presence of spraying or standing water it may cause a shock This pump is not suitable for use in Class or Class II explosive gas or dust locations Do not cover the pump air vents The pump is air cooled Do not cover the vent holes located on the top or sides of the pump housing The pump The pump has a built in tank that collects the water from the appliance When the water collected reaches sufficient level inside the pump tank the pump switches on and pumps the water to a remote location for disposal When the tank is sufficiently empty the pump automatically switches off The pump is capable of liffing water to its rated height and is equipped with a check valve that prevents water from flowing back into the tank when the pump shuts off The pump is outfitted with lights that show the status of power available motor running and high water alarm conditions The pump is also equipped with a switch that activates when the water in the tank reaches an overflow condition The overflow safety switch may be connected to turn off the appliance if the high water condition occurs The switch also has an alarm terminal that may optionally be con
15. will result in a malfunction of the case particularly when the discharge and return air sections are covered Please keep products within the load limits shown on this diagram 8 Deep 10 Deep 12 Deep 15 Deep 18 Deep 21 Deep 200 Ib Shelf Load Limits The weight limits listed here are with the shelf level and the weight evenly distributed Exceeding these ratings could cause damage and or bodily harm Page 22 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Maintenance amp Care Information General Care and Cleaning Long life and the satisfactory performance of any equipment is dependent upon the care it receives To ensure a long life proper sanitation and minimum maintenance costs these cases should be thoroughly cleaned all debris removed and the interiors wiped down weekly at a minimum Exterior Surfaces The exterior surfaces may be cleaned with a mild detergent and warm water to protect and maintain their attractive finish NEVER USE ABRASIVE CLEANSERS OR SCOURING PADS We recommend Murphy s Oil Soap used per manufacturer s directions for the cleaning of wood veneer surfaces on refrigerated cases Interior Surfaces The interior surfaces may be cleaned with most domestic detergents ammonia based cleaners and sanitizing solutions with no harm to the surface Case Cleaning and Maintenance DO NOT use abrasive cleansers and scouring pads
16. 1 Air conditioning ducts that are positioned or blowing directly into an open case will impair case performance Also any air current from prep areas or ceiling fans can impair the performance of a case 2 Ovens or other forced air heating systems placed near the case can affect the case air curtain and impair the temperature performance of the case DO NOT WALK ON TOP OF THE CASE These cases are not designed or built in standard models to support extra weight on top Heavy weight placed on top of the case may cause damage to the case as well as personal injury DO NOT TILT SELF CONTAINED CASES more than 15 from vertical when setting in place Compressors may be damaged Compressor warranty may be voided If the self contained case has been tilted wait at least 24 hours before turning the case on DO NOT USE RUNNING WATER ON CASES EQUIPPED WITH A CONDENSATE PUMP It is important to not introduce more water than the case condesate pump can handle The case must be routinely wiped out and cleaned by hand or the pump can be damaged and cause flooding or personal injury See care instructions for these pumps in optional equipment 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Page 5 General Information WARNING Use caution and keep hands out of the way when lifting the case to remove dolly FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY These cases unless otherwise specified are shipped on d
17. 1 Panel installation using 2 rear brackets Fig 3 a insert the instrument in the opening secure the instrument by sliding the brackets in the guides on the instrument until compressing them against the panel 2 m o oo gt 00 fa lt 2 Fig 3 a Removing from the panel with brackets release the instrument by pressing both brackets where marked push and sliding it back on the guides 3 2 Panel installation from the front using screws Fig 3 b the thickness of the fastening panel must not exceed 12 inch remove the front frame and make sure that the two catches in place these must not protrude from the outline of the drilling template If necessary unscrew the two screws Do not unscrew excessively the screws must not be detached from the front panel 1 insert the instrument in the opening in the panel and hold it in position by the center of the front panel 1 using the screwdriver tighten the bottom screw 90 The catch must come out of its slot and click onto the panel then tighten until the front panel is secure Do not over tighten When the front panel is secured simply make another 7 turn to compress the gasket If the catch does not click onto the panel unscrew the screw applying pressure at the same time with the screwdriver so that the catch moves back Do n
18. 2 F GE dc time base 0 0 AO alarm and fan temperature differential 20 20 C F 0 AL absolute relative temperature for low temperature alarm 50 50 C F 10 AH absolute relative temperature for high temperature alarm F 50 50 CPF 60 Ad temperature alarm delay C 0 199 min 30 A4 3rd input configuration 0 1 0 7 digital input alarm delay C 0 199 min 0 A8 enable alarm Ed end defrost by timeout 0 0 set point dirty condenser alarm 50 150 C PF 0 dirty condenser alarm differential temperature 0 1 200 CPF 0 Acd dirty condenser alarm delay 0 250 min 0 HO serial address C 0 207 1 H1 AUX output configuration C 0 3 0 H2 enable keypad C 0 1 1 H4 disable buzzer 0 1 0 5 ID code read only F 0 199 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Page 19 Optional Condensate Pump SAFETY WARNING FOLLOW ALL SAFETY INFORMATION TO REDUCE POTENTIAL ELECTRICAL SHOCK DISCONNECT POWER BEFORE SERVICING UNIT PUMP MUST BE PROPERLY GROUNDED NEVER USE THE PUMP TO MOVE FLAMMABLE LIQUIDS NEVER USE THE PUMP IN AN EXPLOSIVE GAS ENVIRONMENT OR WHERE GAS FUMES OR VAPOR MAY BE PRESENT ALWAYS DISCONNECT THE POWER PRIOR TO MOVING ADJUSTING OR SERVICING THE PUMP OR ATTACHED SYSTEMS Power Source Supply voltage and frequency must match what is shown on the pump nameplate Source
19. 467 Adoue5 1467 H pion 00 Ued 33 401 S pnoJug uey 109 9 dd peius jeonJeA 55819 4I 4 1ees dn dij4 OO quio 99 sse 5 ju0JJ 3214 49402 uiseg 3 9Dpe 2 NN 1945 eiqeisn py 88 Sse c 10014 peAun2 55219 00 5 yoddns Adoueg WW vv o 9 2 pIeius 77 1945 euiuezzew Z ued 34 11023 8 55215 aedy W 1919497 JSN V No oa 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Page 28 MAINTENANCE SCHEDULE MONTHLY PERFORMED BY COMPANY DATE NOTES SEE UNDER MAINTENANCE AND CARE INFORMATION IN THIS MANUAL FOR MAINTENANCE CHECK LIST 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Page 29 Page 30 MAINTENANCE SCHEDULE MONTHLY NOTES ERFORMED BY COMPANY MAINTENANCE SCHEDULE ANNUALLY PERFORMED BY COMPANY DATE NOTES SEE UNDER MAINTENANCE AND CARE INFORMATION IN THIS MANUAL FOR MAINTENANCE CHECK LIST 2013 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Warranty amp Compliance Limited Warranty TWELVE MONTH WARRANTY SOUTHERN CASEARTS INC S
20. AL low temperature alarm threshold deviation high temperature alarm threshold deviation 6 Navigating Parameters The operating parameters modifiable using the keypad are divided into two types frequent type F and configuration type C Access to the latter is protected by password default 22 to prevent accidental or unauthorized modifications Accessing the type F parameters press the SET button for more than 3 s if there are active alarms mute the buzzer the display shows the parameter code 5 password use the UP and DOWN buttons to scroll the parameters The LED corresponding to the category of parameters will be on see Table 5 b press SET to display the value associated with the parameter increase or decrease the value using the UP or DOWN button respectively press SET to temporarily save the new value and display the parameter again repeat the procedure for any other parameters that need to be modified press the SET button for more than 3 s to permanently save the parameters and exit the parameter setting procedure Accessing the type C parameters press the SET button for more than 3 s if there are active alarms mute the buzzer the display shows the parameter code PS password press the SET button to access the password setting use the UP and DOWN buttons to scroll the numbers until displaying 22 password to access the parameters press the SET button to confirm th
21. OR STAND ON TOP OF DECKS SHELVES OR CASES FOR ANY REASON and serious personal injury could occur THEY ARE NOT STRUCTURALLY DE SIGNED TO SUPPORT EXCESSIVE EXTER NAL LOADING such as the weight of a person DO NOT PLACE HEAVY OBJECTS ON THE CASE If work is to be done above the fixture then ladders and or scaffolding must be used IMPORTANT If the correct lift points are not identified prior to removal Look for the supports under the unit before removing pallet f not removed it will damage the finished metal IMPORTANT Installation of 3rd party material may result in improper case performance Page 7 Installation Instructions Locate and verify placement of cases inside the store building Unload and move cases as close as possible to their final location Verify that no changes have been made to area and that blueprints are still current Find points of reference to take dimensions to help locate the cases Leveling is very important and necessary to ensure proper case alignment when installing Improper leveling can affect the refrigeration systems and lead to improper drainage of defrost water To ensure proper leveling locate the highest point on the chalk line as a reference to determine the height the leveler legs need adjusting Page 8 Mark the floor where cases are to be located for the entire lineup Roll the first case into p
22. S RESERVED FABRICATION BY COPYRIGHT 2006 CIRCUIT INTERRUPTER PLUG Le 2L T 5 BALLAST RED YELLOW ANTI SWEAT IF ONE SHELF IS UNPLUGGED THE CAP HEATERS HAS TO BE IN PLACE FOR THE OTHER LAMPS TO WORK ON THAT BALLAST DUE TO THE ANTI ARCH PLUG 205 428 4800 phone 205 428 7788 fax STORE FIXTURES INC 275 DREXEL ROAD SE BESSEMER AL 35022 THE NUMBER OF LIGHTS FANS AND ANTI SWEAT HEATERS ARE DETERMINED BY CASE SIZE AND STYLE Drawn 8 CONTROLS CONDENSATION PUMPS AND OUTLETS ARE OPTIONAL EACH OUTLET IS WIRED TO A C SALTER SEPARATE JUNCTION BOX 12 30 09 1 1 0 QAElectricalWiring Diagrams WIRING DIAGRAMS 2014 dwg June 10 2015 10 50am Printed cwalker 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Page 12 Information Electr NEMA L14 30P stack BLUE SMOOTH FRIBBED TERMINAL BLOCK 30 AMP CONTACTOR NEMA L14 20P WHITE CIRCUIT INTERRUPTER PLUG i 4L T 5 BALLASTE BLUE RED YELLOW CIRCUIT INTERRUPTER PLUG PURPLE i 4L T 5 BALLAS lt gt BLUE j RED YELLOW CIRCUIT INTERRUPTER PLUG ff 2L T 5 BALLAST RED YELLOW SO 2FROMT CIRCUIT INTERRUPTER PLUG
23. TER SEPARATE JUNCTION BOX 5 12 30 09 1 1 0 QAEI g Diagrams WIRING DIAGRAMS 2014 dwg June 0 50am Printed By cwalker Page 11 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 ion Informat Electr CONDENSATION PUMP 3 4 T 5 BALLAST LIGHT SWITCH EXE Lion o sinon TERMINAL BLOCK 3 41 T 5 BALLAST TERMINAL BLOCK DETAIL TYPICAL REMOTE CASE SOLENOID CIRCUIT INTERRUPTER PLUG mem FAN BOX 4L T 5 BALLASTS BLUE RED YELLOW iE BLACK CIRCUIT INTERRUPTER PLUG APPROVAL 3 RIBBED LIGHTS BOX CA Kl K 2 K Xi K 2 Kl RI BLUE e RED Xi YELLOW Kl Ri K 2 K Xi K 2 Kl 2 S 4 VARIABLE CIRCUIT INTER VOLTAGE CONTROL ra 5 5 RED YELLOW THIS DRAWING IS THE PROPERTY OF SOUTHERN STORE FIXTURES INC AND IS NOT TO BE REPRODUCED OR EXCHANGED WITH ANY OTHER PERSON OR COMPANY WITHOUT THE EXPRESS WRITTEN CONSENT OF SOUTHERN STORE FIXTURES INC SOUTHERN STORE FIXTURES INC ALL RIGHT
24. Y GLASS COMPONENTS OF THE CASE Glass breakage may result in serious injury Store Conditions Southern CaseArts refrigerated standard display cases are designed for use in Class 1 air con ditioned stores where the temperature does not exceed 75 F and the relative humidity does not exceed 55 Air conditioning fans ovens drafts direct sunlight or anything that could disturb the air inside the case could result in poor performance Page 4 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 General Information General Information Display cases described in this operation guide are part of the 700 series of product displays provided by Southern CaseArts Inc This guide covers the following product display models FLX These cases are not designed to cool down products but are designed to maintain the safe temperature of the product once placed in the case Keep products at food safe temperature prior to loading them into the case Allow the case to operate a minimum of 4 hours before loading with product Do not place any product into a display case until it is at operating temperature Discharge air plenum and return air grill must not be blocked or restricted the case may not operate properly Overloading the case may impair the proper operation of the case For self contained models the air intake grill and discharge vent must be clear of obstructions or the case will not operate properly
25. ax 905 498 9559 Your Exclusive Source for Innovative Food Displays Installation Maintenance amp Operation Guide P N LD MN 0035 0113 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 southerncasearts com
26. case operating at its best we suggest the following maintenance schedule The yearly service should be performed by a qualified service technician Before doing monthly or yearly servicing BE SURE TO DISCONNECT ALL POWER SUPPLIES TO THE CASE TUTTI DISCONNECT POWER BEFORE CLEANING OR he coil cover only lift out for an inspec tor or trained service provider May re SERVICING THIS UNIT FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY OR DEATH sult in damage of the refrigerant system if removed by a untrained person 1 The cases should be wiped down daily and cleared of all debris 2 The product placement within the cases should be checked to ensure proper air flow to all products 3 Be sure the air return grill is not blocked and the discharge air is at a normal velocity 4 Be sure the air filter on the condensing unit is not clogged or dirty Page 24 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Maintenance amp Care Information MONTHLY cleaning should consist of 1 The cases should be broken down and cleaned thoroughly 2 Remove honeycomb holder and wash honeycomb 3 Wipe fan blades and fan guards 4 Vacuum tub fan shrouds top and bottom and coils where possible 5 Remove debris from drain and clean evaporator pan 6 Take out the air filter for the condensing unit and wash thoroughly and replace ANNUAL system check up and adjustment Compressor 1 Check co
27. clean Are the discharge or return air vents blocked PROBLEM CASE LEAKS WATER ON FLOOR Is the ambient air above 55 relative humidity Is case drain clogged Is evaporator pan or condensate pump overflowing The electric dissipater pan cannot handle being flushed with water from cleaning Cases equipped with electric dissipater pans should never have food products washed or poured into the drain as it will result in damage to the heating element Make sure all case joints and penetrations are sealed PROBLEM CASE SWEATING e 5 the relative humidity above 55 and 75 sthe case near an open door or window sthe air sweep working FOR SERVICE PARTS AND WARRANTY INFORMATION CALL 800 552 6283 Please have model and serial numbers ready This information can be found on the name plate of the case 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Page 27 PARTS LEGEND 9522 yoeg 2522 X IUD Jy 7 5 pasop 1467 xoeg 10014 HH 51000 4 A Bulson uinuiun y 1UBIN SS uunumunjy ISSE 99 314 pion Jeduung dois YY 44 1
28. ct 4 Regarding the actual merchandising of the products in the case Is the product or case decoration obstructing the air discharge or return air Is the product exceeding the load limit of the case Good judgement should be utilized concerning rotation of product On most cases other than multi level service cases the load line or refrigerated zone can be determined by drawing a line from the rear of the discharge air grill to the return air intake Everything under this line is considered within the refrigerated zone 5 All deck pans should be seated properly in the base of the case with all fan plenums securely in place All fans must be operational 6 For self service open case merchandising please consider the following A Air conditioning ducts blowing directly into an open case will impair the performance Any air current from prep areas or ceiling fans can also impair the performance of the cases B Spotlights ovens or forced air heat systems placed near the cases can affect the case air curtain and the temperature performance of the case 7 Do NOT walk on top of the case 8 Remote system problems that potentially impair case performance A Evaporator temperatures should be maintained at settings specified for each case in our technical manual B Variations in liquid temperature affect the expansion valve performance Are all of the sub cooled liquids maintained at a constant temperature C Does the system have enou
29. e float is raised to the upper part of its travel Leak Check Operate the pump by filling tank to trigger operation Pump RUN will be indicated by the yellow RUN LED WARNING DISCONNECT POWER BEFORE CLEANING OR SERVICING THIS UNIT FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY OR DEATH Pump Maintenance and Disassembly Always disconnect power before performing maintenance Pump and deck may be removed from the tank by pushing tabs located on the tank sides away from the deck while lifting on the Pump cover Periodically inspect the Pump tank to assure it is free of accumulated dirt or sludge Do not use solvent cleaners Clean tank with soap and warm water only The check valve may be removed for cleaning or replace ment by unscrewing with a 9 16 wrench illustration Clean inlet and outlet piping Tubing may be cleared of slime or debris instantly with a Wagner brand Gallo Gun tool and Swoosh cartridges Add Pro Treat Tabs to the tablet tray Reassemble system and check for correct operation 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Page 21 Air Flow amp Product Loading General Information and Diagram Cases have been designed with an air delivery system to provide maximum product capacity It is important that you DO NOT OVERLOAD THE FOOD PRODUCT DISPLAY so that it disrupts the air delivery system Overloading will cause the loss of proper temperature levels and
30. e password use the UP and DOWN buttons to scroll the parameters The LED corresponding to the category of parameters will be on see Table 5 b press SET to display the value associated with the parameter increase or decrease the value using the UP or DOWN button respectively press SET to temporarily save the new value and display the parameter again repeat the procedure for any other parameters that need to be modified press the SET button for more than 3 s to permanently save the parameters and exit the parameter setting procedure A Warnings If no button is pressed for 60s all the changes made to the parameters temporarily saved in the RAM will be cancelled and the previous settings restored If power is disconnected from the instrument before saving the settings pressing the SET button for 3 s all the changes made to the parameters and temporarily saved will be lost Control Information The dAY hr Min parameters are not restored as these are saved instantly when entered Category Initial Icon Probe parameters Control parameters r Compressor parameters Defrost parameters d D3 Alarm parameters A a Fan parameters F lt AUX output configuration parameters H1 RUX RTC parameters 7 Setting Parameters 7 1 Quick Set Parameters This is a basic list of parameters to quickly start a control table 7 a and low temperature units table 7 b 7 a For medium
31. eck inside the cabinet Inspect and check operation of all safety controls Make sure all panels are secure and secure with screws where necessary Check and clean condensate drain lines and pans 9 Check drain for proper trap installation and that trap is holding water 10 Check for proper draining Verify that all debris is clear and drain is working properly 11 Check condensate pump for proper operation and clean by flushing with bleach 12 Check for proper temperatures on all levels and sections of case log temperatures 13 Blow out dust from screens in plenums AVOID ARCING OR POSSIBLE FIRE OR SAFETY HAZARDS WARNING hen working in a case where the coil cover is removed use extreme caution The coil contains CONN NN BW 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Page 25 Trouble Shooting Remote Cases Trouble Shooting Remote Cases We have prepared a listing of potential case problems and how to diagnose performance issues 1 Is the expansion valve superheat set correctly at 5 7 Fahrenheit 2 15 the product at proper temperature when it is received from the cooler for merchandising These cases are designed to maintain safe temperature once the product is placed in the case However the cases are not designed to cool down the products from unsafe temperatures 3 Always allow the cases to operate for a minimum of four hours before loading with produ
32. gh refrigerant to maintain all of the remote case applications D It is essential that the specified defrost requirement for each case is followed to ensure product integrity while at the same time defrosting the case efficiently E It is recommended that liquid and suction lines are sized correctly for each case lineup If other cases are connected in combination this could affect suction pressure G EPR s at the case or at the system must be set to maintain the proper evaporator temperatures Case temperatures are to be controlled by the factory T stat or suction solenoid DO Do NOT walk on top of the case These cases are not designed or built in standard models to support extra weight on top Heavy weight placed on top of the case may cause damage to the case as well as personal injury Page 26 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Trouble Shooting Self Contained Cases Trouble Shooting Self Contained Refrigerated Cases PROBLEM WILL NOT HOLD TEMPERATURE Check the electronic thermostat setting e Is the air filter clogged or dirty Are any air conditioner vents blowing into or toward the case Are any spotlights shining into the case Is the case near a door Is the case in direct sunlight Is there cooking equipment or hood vent causing air currents Is the ambient air above 75 F or 55 relative humidity Is the condensing coil clean Is the evaporator coil
33. he product and the software included with the product respond to the requirements of the final application despite the product being developed according to start of the art techniques The customer manufacturer developer or installer of the final equipment accepts all liability and risk relating to the configuration of the product in order to reach the expected results in relation to the specific final installation and or equipment CAREL may based on specific agreements acts as a consultant for the positive commissioning of the final unit application however in no case does it accept liability for the correct operation of the final equipment system Operation of the Carel product is specified in the technical documentation supplied with the product or can be downloaded even prior to purchase from the website www carel com Each CAREL product in relation to its advanced level of technology requires setup configuration programming commissioning to be able to operate in the best possible way for the specific application The failure to complete such operations which are required indicated in the user manual may cause the final product to malfunction CAREL accepts no liability in such cases Only qualified personnel may install or carry out technical service on the product The customer must only use the product in the manner described in the documentation relating t
34. lass Improper cleaning not only degrades the quality of the surface but also accelerates the frequency of required cleanings Incorrect cleansers have a tendency of causing small scratches in the surface which over time will appear as a haze in the plastic We recommend using soft cotton cloths Fluorescent lamps contain mercury vapor which can be harmful if exposed Make sure and replace all lamps with the approved shatter shields Visit http www epa gov osw hazard wastetypes universal lamps index htm for more info 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Page 23 Maintenance amp Care Information Cleaning Non glare Glass Our non glare glass receives a special coating on the glass surface The special coating is applied in a manner to ensure that the high optical clarity of the glass is maintained To protect this special coating and optical clarity it is essential that the glass be kept clean Glass Plus or Windex are the only solutions recommended for use on non glare glass You should only clean with a micro fiber cleaning cloth Scotch Brite and Spontex are two common manufacturers of these cloths A micro fiber cloth can clean the glass without the use of the solutions Cleaning solutions should only be used for tough jobs NOTE Once the glass has been damaged with improper solutions it is irreparable Special Directions Certain precautions should be taken before c
35. leaning the inside portion of the lift up glass We recommend that the glass be fully opened to prevent cleaning solution from splashing onto the food products While cleaning the cases we recommend that the non glare glass be fully opened and covered so that no cleaning solution will splash onto the non glare glass coating UNDER NO CIRCUMSTANCE should you use coarse paper towels scouring pads powders steel wool steel fiber materials blades acidic detergents highly alkaline detergents or fluorine based detergents to clean non glare glass Air Sweep Fan Assembly The fans are located on the bottom of the tub These fans must be checked every three months to make sure air can pass through them If they are clogged remove any dust or debris If proper air flow is not maintained then it could cause sweating glass and poor product visibility WARNING Electric dissipater pans are meant solely for the purpose of evaporating condensate water released from the refrigeration coil during the defrost cycle Dust food products grease caustic liquids flammable materials wash water and or cleaning chemicals should not be allowed to accumulate in the pan Regular monthly maintenance should be performed to make sure the pan is clean and the float switch moves up and down freely Failure to follow these guidelines could result in flooding overheating and or a fire hazard and will void the warranty To keep your Southern CaseArts
36. mpressor for indications of flooding Check and log suction discharge and saturated liquid line temperatures 2 Check temperature differential across liquid line drier 3 Check operations pressures of refrigeration cycle verify full sight glass during normal operation 4 Check unit for excessive noise vibration and short cycling Electrical WARNING 1 Inspect clean and tighten all electrical components AFTER CLEANING 2 Check and document amp draw for the following OR MAINTENANCE ALL LIGHTING AND A Compressor FAN ELECTRICAL B Line voltage C Condensing fan motor amperage t di CONNECTIONS Inspect disconnect and fuses MUST BE DRIED AND 3 Check contactor for signs of burnt contacts FULLY SEATED TO Condenser and evaporator fan motors 1 Check for proper rotation and operation 2 Check fan blades for damage 3 Check motor mounts for damage 4 Clean all dirt and debris from fan blades 5 Check for proper operation during both refrigeration and defrost 6 Check bearing for vibration and noise 7 Check fan motors for abnormal vibration and noise General 1 Perform coil cleaning on evaporator and condenser coils Remove and clean honeycomb diffusers Check and adjust controls defrost time clocks and thermostats Many sharp edges that can Check superheat and adjust to proper setting if necessary cut your hand or arm Check for refrigeration leaks on all equipment Leak ch
37. nected to an audible alarm or remote indicator light to indicate a trouble condition Page 20 Equipment CP 22 CP 22LP CP 22T CP 22LPT Rated Voltage 120 Volts 60 Hz Rated Current Draw 1 2 Amps Head 22 ft maximum Height Flow Rate 1 6 GPM at Zero Head 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Optional Equipment Outlets and Tubing Connections The pump is equipped with a combination barb type fitting and check valve The fitting allows the connection of 3 8 flexible vinyl tubing such as DiversiTech clear vinyl Attach the tubing by pressing it over the barb fitting and secure with a screw type hose clamp Route the tubing up and away from the pump avoid compressing or kinking the tubing The tube route should be the shortest possible distance from the pump to the building exterior or other drain location For best results the distance that the water must go UP should be shorter than the distance that it goes DOWN With the longer DOWN tubing the length will help siphon the condensate from the tank speeding the pump out time Pump Operation Apply power by plugging in the pump Check for green LED indication the power is available Test float and safety switch by filling the tank or manu ally operating the float see disassembly below Test Safety Switch operation if used to be sure that the A C system shuts down and the red ALARM LED lights when th
38. ng system on a display case with shelf light ing can lead to a number of serious issue This could cause electrical failures electric shock fire and mold which could lead to injury death sickness and property damage Do not use water hoses mist ing systems or any device that sprays liquid on a display case with lighted shelves The lighting on the case is not designed to be exposed to water or other liquids If a water hose or misting system is used or installed Southern CaseArts will not be subject to any liabilities or obligations Any personal injury death or property damage resulting from an electrical failure fire electric shock or mold South ern casearts shall not be subject to any obligation or liabilities from the above notice WARNING Improper voltage on the DC power supplies may damage the LED lamp WARNING LED 12v DC power supply needs to be replaced with a 12v DC power supply Led 24v DC power supply need to be replaced with a 24v DC power supply Never use a T5 T8 ballast of any kind to replace 12v DC or 24v DC power supply T5 T8 ballasts are much higher voltage and operate on AC not DC current If a T5 T8 ballast is used for replacement to a DC power supply it will damage the LED system and could cause injuries fire or damage to case Page 32 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 SOUTHERN CaseArts 975 Drexel Road S E Bessemer AL 35099 Phone 800 552 6283 F
39. nt without prior warning The technical specifications shown may be changed without prior warning The liability of CAREL in relation to its products is specified in the CAREL general contract conditions available on the website www carel com and or by specific agreements with customers specifically to the extent where allowed by applicable legislation in no case will CAREL its employees or subsidiaries be liable for any lost earnings or sales losses of data and information costs of replacement goods or services damage to things or people downtime orany direct indirect incidental actual punitive exemplary special or consequential damage of any kind whatsoever whether contractual extra contractual or due to negligence or any other liabilities deriving from the installation use or impossibility to use the product even if CAREL or its subsidiaries are warned of the possibility of such damage Control Information 2 General Description easy and easy compact are electronic microprocessor controllers with LED display developed for the management of refrigerating units display cabinets and showcases They exploit the experience and the success of the previous PJ32 range with the objective of offering a product that is simpler and more economical The structure of the parameters has been enhanced with new functions for more dynamic and effective management of the temperature control and defrost 3 Assembly and Installation 3
40. ntil entire line up is set Page 9 Installation Instructions Make sure all the shelves are securely in position and the plugs for the shelf lights are plugged in all the way Install any joint caps sent with the case WARNING Make sure all shelves with lights are plugged in all the way and seated completely Unused receptacles must have the cover pushed all the way in and seated completely Failure to do this could result in arcing possible fire or safety hazzards After the mechanical connections are made all penetrations must be sealed and all panels and kick plates must be installed If 90 of the floor under case cannot be accessed by a 1 5 diameter rod for cleaning then silicone kick plate to floor IMPORTANT That all the piping connections are compliant with local codes IMPORTANT Necessary when brazing wet rag around the area to avoid any damage IMPORTANT Remove all styrofoam shipping blocks from case Failure could result in case damage Page 10 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Information Electr CONDENSATION ee E LIGHT SWITCH EXE NEC TERMINAL BLOCK 3 41 T 5 BALLAST TERMINAL BLOCK DETAIL TYPICAL REMOTE CASE
41. o the product In addition to observing any further warnings described in the manual the following warnings must be heeded for all CAREL products prevent the electronic circuits from getting wet Rain humidity and all types of liquids or condensate contain corrosive minerals that may damage the electronic circuits In any case the product should be used or stored in environments that comply with the temperature and humidity limits specified in the manual do not install the device in particularly hot environments Too high temperatures may reduce the life of electronic devices damage them and deform or melt the plastic parts In any case the product should be used or stored in environments that comply with the temperature and humidity limits specified in the manual donotattempt to open the device in any way other than described in the manual do not drop hit or shake the device as the internal circuits and mechanisms may be irreparably damaged donot use corrosive chemicals solvents or aggressive detergents to clean the device do not use the product for applications other than those specified in the technical manual All of the above suggestions likewise apply to the controllers serial boards programming keys or any other accessory in the CAREL product portfolio CAREL adopts a policy of continual development Consequently CAREL reserves the right to make changes and improvements to any product described in this docume
42. ollies for ease of unloading If the loading dock is level When moving a case without casters into position it is recommended to only use a jack bar and dollies Cases have a wide with the truck the cases can be rolled off Be careful around pinch variety of electrical drain and refrigerant the truck and into the store points they can cause bodily connections under the case and may be h damaged by moving the cases arm Case Industry Standards The 700 Family of cases conform to the following standards Intertek Intertek Installation Instructions Southern CaseArts remote series of cases WARNING are shipped to stores with dollies on casters placed beneath the base frame From loading to unloading and placement to installation Do not push or pull on any glass we strive to ensure that moving the cases is components of the case Glass easy for everyone involved In most instances breakage may resultin serious injury one or two people may move the cases with ease Our self contained series of cases unless otherwise specified when ordering are IMP 0 RTANT generally always manufactured with heavy duty casters mounted permanently to the base If forklifts or pallet jacks are used frame for ease of mobility when unloading to move cases use a spotter to and when moving around for placement in the guide forks into place to prevent store If a forklift or pallet jack is used to move damage to electrical plumbing and cases use
43. osition Use a jack bar and place it on the underside of the heavy duty steel frame to lift the case and remove all dollies CAUTION KEEP HANDS OUT OF THE WAY AT ALL TIMES TO AVOID INJURY 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Roll the next case into position leaving a few feet in between from the adjoining case for maneuvering Repeat step 4 for removing dollies from beneath the case CAUTION KEEP HANDS OUT OF THE WAY AT ALL TIMES TO AVOID INJURY MAKE SURE AND LEVEL ALL CASES For shipment the leveler legs on the cases are run all the way out IT IS VERY IMPORTANT TO SCREW THE LEVELER LEGS ALL THE WAY IN BEFORE LEVELING THE CASE WHEN THE CASE IS LEVEL MAKE SURE ALL THE LEVELER LEGS ARE SECURE TO THE FLOOR 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Installation Instructions Remove anything from the case that could interfere with the case joining Run a bead of sealant around the entire end before pushing cases together tightly Make sure all alignment pins are in place before running a bead of sealant and pushing the case together Push cases tightly together and bolt them through the holes provided Tighten until all margins are equal DO NOT OVER TIGHTEN Repeat steps 4 8 u
44. ot unscrew too much the head of the screw must not be raised from the surface of the front panel 2 repeat the same operation for the top screw 2 apply the front frame 3 Fig 3 b do not over tighten the screws Dismantling using the screws from the front uncdlip the front frame unscrew the bottom screw at the moment the front panel detaches from the panel keep pressure on the screw and unscrew a further 90 to make the catch go back into its slot repeat for the top screw remove the instrument from panel keeping it horizontal 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Control Settings 3 3 Wiring Diagram Wc EM exis NTC PTC PROBES la 35 230Vac or 6 7 9 10 11 NTC PTC PROBES 617 8 9 3 El 230Vacor lt PROBES Beea 6 7 s 9 10111 PJEZS E Easy PJEZ S X i 115 Vac or N 12 Vac Vde PJEZ C Y 1 2 3 4 5 co 115 Vac or 12 Vac Vde N PJEZ M Li n L 230Vacor lt N 115 Vac or 12 Vac Vde Easy Compact PJEZS 0 PJEZS 1 NTC PROBES 41516 Wires 415 PJEZM N 0 PJEZM N 1 PROBES
45. sion valve is hunting 3 Do not set the superheat until cases have pulled down to operating temperature and never open or close the valve over1 4 turn between adjustments and allow 10 minutes or more between adjustments 4 Superheat should be set at 6 8 F 5 After the initial setting the superheat should be rechecked when product is stocked and at designed temperture Superheat Calculations EXAMPLE R404 33F Suction temperature 28F Suction pressure converted to temperature 5FSuperheat 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Page 15 Page 16 PJ Easy Easy Compact digital electronic thermostats with defrost controls 1 GENERAL WARNING 1 2 GENERAL DESCRIPTION 3 ASSEMBLY AND INSTALLATION 3 1 REAR PANEL INSTALLATION AND REMOVAL 3 2 FRONT PANEL INSTALLATION AND REMOVAL 3 3 WIRING DIAGRAM 4 USER INTERFACE AND STARTUP 4 1 DISPLAY 4 2 KEYPAD FUNCTIONS PRELIMINARY CONFIGURATIONS NAVIGATING PARAMETERS SETTING PARAMETERS PROGRAMMING KEY Am General Warning CAREL bases the development of its products on decades of experience in HVAC on the continuous investments in technological innovations to products procedures and strict quality processes with in circuit and functional testing on 100 of its products and on the most innovative production technology available on the market CAREL and its subsidiaries nonetheless cannot guarantee that all the aspects of t
46. t 2 accesses the parameter set procedure setting menu enter password 22 mutes the audible alarm buzzer 3 more than 3 s activates pressed together foris deactivates the defrost with 1 activates displays deactivates the firmware continuous cycle version Keypad functions for easy and easy compact M models models with keypad only no normal operation pressing the button alone start up more than 3 s switch ON OFF 1 s displays sets the set point more than 3 s accesses the parameter pressed together activate parameter setting menu enter password 22 reset procedure mutes the audible alarm buzzer for 1 s displays 3 rapid selection of probe displayed firmware version 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Page 17 5 Preliminary Configurations Once the electrical connections have been completed simply power up the controller to make it operative CAREL then recommends checking that the display does not show any alarm signals then set the time and date and finally set the parameters as desired The main parameters are as follows Control parameters st set point rd set point differential Defrost parameters d 0 type of defrost d interval between two defrosts dt end defrost temperature maximum defrost duration d Alarm parameters Ad temperature alarm delay
47. temperature applications er for both medium Parameter Description Setting 5 Select C F 1 St Set Point 34 rd Control differential 6 dl Interval before defrosts 0 7 b For low temperature applications Parameter Description Setting 5 Select C F 1 St Set Point 5 rd Control differential 6 dl Interval before defrosts 6 End defrost temperature set point dt defrost temperature threshold with 45 temp control dp maximum defrost duration 25 7 2 Resetting to factory defaults Warnings Running this procedure overwrites any custom parameter settings To reset the default parameters disconnect power from the instrument reconnect power while holding the SET and DOWN buttons the display will show the message afterafew seconds the instrument starts operating with the default configuration Any different parameter settings will need to be updated Page 18 2014 Southern CaseArts Inc is a Southern Store Fixtures Inc company 800 552 6283 Control Settings CAREL Default Settings EZY Par Description Type Min UOM 0 123 PS password F 0 200 22 2 probe measurement stability 1 5 8 4 select probe displayed F 1 3 1 5 select C F OCC
48. the agent otherwise the carrier may refuse the claim Concealed Loss or Damage When loss or damage is not apparent until after the equipment is unpacked or uncrated retain all packing materials and submit a written request to the carrier for inspection within 15 days of receipt of equipment Exterior Loading DO NOT WALK OR STAND ON TOP OF DECKS SHELVES OR CASES FOR ANY REASON or damage to the cases and serious personal injury could occur THEY ARE NOT STRUCTURALLY DESIGNED TO SUPPORT EXCESSIVE EXTERNAL LOADING such as the weight of a person DO NOT PLACE HEAVY OBJECTS ON THE CASE If work is to be done above the fixture then lad ders and or scaffolding must be used Handling of Cases Southern CaseArts remote series of cases are shipped to stores with dollies on casters placed beneath the base frame From loading to unloading and placement to installation we strive to ensure that moving our cases is easy for everyone involved In most instances one or two persons can move the cases with ease Our self contained series of cases unless otherwise specified when ordering are generally manufactured with heavy duty casters mounted permanently to the base frame for ease of mobility when unloading and when moving around for placement in the store If a forklift or pallet jack is used to move the case use a spotter to guide forks in place to prevent damage to electrical plumbing and refrigeration lines DO NOT PUSH OR PULL ON AN