Home
USER MANUAL - Jon-Don
Contents
1. NKSL NATURAL 5 LITER TANK WITH PRESSURE GAUGE WAAD 5 WAADING FOR PUMP UP FOAMER 1 2 in DIA WAAD 625 WAADING FOR PUMP UP FOAMER 625 in DIA Model Number 5L PSG Page 4of4 04142015
2. USER MANUAL MODEL NUMBER 5L PSG 1 3 gallon 5 liter Pump Up Foam Unit English Original Instructions User Manual 1 3 gallon 5 liter Pump up Foam Unit English READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT JA WARNING O Q Read this manual completely and understand the machine before operating or servicing it Read all instructions before installing or operating unit Always wear appropriate personal protective equipment PPE when operating or servicing unit Always follow all chemical safety precautions and handling instructions provided by the chemical manufacturer and Safety Data Sheet SDS If this unit is modified or serviced with parts not listed in this manual the unit may not operate correctly Never point the discharge wand at yourself another person or any object you do not want covered in chemical Never leave unit unattended while pressurized Always depressurize unit before attempting to remove the pump assembly Always depressurize unit after use as described in the After Use Instructions Always store unit depressurized Do not pressurize unit by any means other than the built in pump assembly Do not modify or remove pressure relief valve Do not use unit if pressure relief valve is not operational Always flush the unit with fresh water for 5 minutes when switching from an alkaline to an acid or an acid to an alkaline Never use unit with hydrocarbons or flammable prod
3. ar and leaks e Check the suction tube for debris and clean as needed e Inspect hoses for leaks or excessive wear e Replace wadding inside triggle handle assembly as needed Replace wadding by following steps below 1 Unthread the wand PUWAND 2 Remove the wadding WAAD 625 inside the wand and discard 3 Insert new wadding in poly wand 4 Remove washer in trigger handle PSG12 and set aside 5 Remove wadding WAAD 5 inside trigger handle and discard 6 Insert new wadding and washer inside the trigger handle 7 Thread the wand back on the trigger handle e Periodically lubricate the pump seal with food safe lubricants To lubricate the pump seal raise pump handle and apply 5 to 10 drops of food safe lubricant between pump and pump sleeve NEVER USE LUBRICANTS SUCH AS WD40 Page 30f 4 04142015 User Manual 1 3 gallon 5 liter Pump up Foam Unit English READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT TANK ASSEMBLY PUF5L PA Carrying Handle Air Pressure Relief Valve H14B H Available per ft Air Pressure Gauge HBSS1214 TANKSL PSG12 PUWAND ITEM NUMBER DESCRIPTION H14B H 1 4 INCH BLUE HOSE GOODYEAR HORIZON Available per ft HBSS1214 1 2 NPT X 1 4 INCH BARB STAINLESS PSG12 1 2 IN POLY SPRAY GUN WITH O RING AND GRAY HANDLE amp 316SS PSGORV PSG12 O RING PUFSL PA PUMP ASSEMBLY FOR 5 LITER PUMP UP FOAM UNIT PUWAND PUMP UP FOAMER WAND TA
4. ucts Do not exceed a fluid temperature of 100 F 37 C PROTECT THE ENVIRONMENT Please dispose of packaging materials old machine components and hazardous fluids in an environmentally safe way according to local waste disposal regulations T 5 Always remember to recycle q Specifications and parts are subject to change without notice Model Number 5L PSG REQUIREMENTS Liquid temperature range 40 100 F 4 4 37 C Chemical compatibility Chemical products used with this equipment must be formulated for this type of application and compatible with unit materials and pump seals For more information on chemical compatibility consult the manufacturer or SDS for your product or contact our customer service department SPECIFICATIONS Power type Manual Chemical pickup type Draws from pre mixed solution Number of products unit can draw from One product Capacity 1 32 gallons 5 liters Discharge hose diameter length 6 ft 1 8 m hose with 1 4 in 6 35 mm inside diameter Discharge wand tip Polypropylene trigger handle with type 65 fan tip Pump seals Viton Page 20f 4 04142015 User Manual 1 3 gallon 5 liter Pump up Foam Unit English READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT Operation Instructions 1 Ensure all air pressure is released from unit by pulling up on the red pressure relief valve Ens
5. ure the trigger handle PSG12 is not in locked position Securely hold the unit and unscrew the pump assembly PUF5L PA from the tank in a counter clockwise motion Follow all instructions from chemical manufacturer Fill tank 3 4 of the way with pre mixed solution Note Do not overfill tank with solution Securely hold the tank and screw the pump assembly back on in a clockwise motion Pressurize the tank by pumping approximately 15 to 20 times or until air pressure gauge reads 25 psi 1 7 bar Note The pressure relief valve will leak if the air pressure is too high Do not overfill tank with air Once the desired pressure has been achieved push the handle down and twist it clockwise to lock it in place To start foaming point the wand assembly at the area you wish to foam and squeeze the trigger handle to discharge foam Release trigger handle to stop foaming After Use Instructions 1 2 Ensure all air pressure is released from unit after each use by pulling up on the red pressure relief valve It is recommended to always empty out remaining solution and run fresh water through the unit to rinse all parts thoroughly after each use and before storage Model Number 5L PSG Maintenance Instructions Warning Always depressurize unit before performing maintenance To keep your unit operating properly periodically perform the following maintenance procedures e Check the pump assembly PUF5L PA for we
Download Pdf Manuals
Related Search
Related Contents
Avaya EU24 User's Manual InLine Cat6 S/FTP 7.5m Verilux VA02 User's Manual takeMS 4GB Micro SDHC Card + Adapter Canton Chrono 502 Samsung RM48D Uporabniški priročnik safety warnings submersible sump pump sp25a, sp33a Philips CD Soundmachine AZ1217 hc-7000a iNSTRUCTIONS-WEB MobileBackup User's Manual Copyright © All rights reserved.
Failed to retrieve file