1. will automatic take turns to display the parameters such as voltage current power and capacity 6 Cautions 1 Connect input and output properly it is forbid to reverse connection otherwise it will be burnout 2 This module is a step down module input voltage need over output voltage more than 1 5 V 3 Output under 6A natural cooling output above 6A shall strengthen heat dissipation 7 Warranty and service Thank you for purchasing our products To maximize the use of the new product features we recommend that you take the following steps 1 Read safe and efficient use instruction 2 Read the warranty terms and conditions We warrants to the original purchaser that its product and the component parts thereof will be free from defects in workmanship and materials for a period of one year from the data of purchase We will repair or replace at its option defective product or component parts Returned product must be accompanied by proof of the purchase date Exclusions This warranty does not apply in the event of misuse or abuse of product or as a result of unauthorized alternations or reapers It is void if the B3606DC DC NC buck module serial number is alternated defaced or removed
2. OPERATING MANUAL B3606 DC DC NG Buck Module December 2013 Zhengzhou Ming He Electronic Technology Co Ltd Contents WV GOMMACE 2 Inspecting Package 3 SUMIMARY ass aaa out eae SAN 3 1 Brief IMtrOGUCtON 2 2 neato WAIN TUN CUON 3 9 4 lInstrument e225 Gotan Structure DeSCnDlOMNs gat ciaacnai teers as 4 2 Display IMMOCUCIION ence Wares Arte ait ie O 0 62 MOGs eshte eden aR 20 functional Modenan Ais ata ade 7 Warranty and service B3606DC DC NC buck module 1 Contact Address No 96 Rui Da Rd Zhengzhou China Tel 86 371 86106382 Fax 86 371 86106382 Zip 450001 E mail sales mhinstek com Website www mhinstek com 2 Inspecting Package Contents When you get a new B3606 DC DC NC buck module please inspect the instrument as follows 2 1 Check if there is damage due to transportation If the package is damaged please retain them until the instrument and accessories are te
3. The range of input voltage 6V 40V The range of output current 0A 6A The range of output voltage 0V 36V 5 1 2 Setting the voltage and the current value You should note that there are no units of the current and voltage users can distinguish them through the position of decimal point The decimal point position of the voltage is in the second decimal place e g 00 00 and the current is in the first e g 0 000 The setting method is as follows After electrify the LED default display the voltage value the format of voltage display is 00 00 press SET button to switch to the current value the format of current value display is 0 000 Press the button to increase the value press the button to reduce the value press the button can accurate regulation press the button for a while can regulate quickly If the voltage or current value has been changed press the SET button the LED display the that the voltage or the current has been saved If there is no change of voltage or current value press SET button will switch to the current or voltage value 5 1 3 After the setting press the OK button to output 5 1 4 Under the output state press the button can increase the value and press the button can reduce the value when the LED display the voltage value press the button can increase the value and press the button can reduce the value when the LED display the current value Press the button can acc
4. automatic output after electricity 5 2 3 Enable the function 1 in the condition of no output press the SET button it will take turns to display the parameters which among voltage 00 00 current 0 000 bring up the parameters Lo 0 and save the parameters SA 0 We will illustrate the function as follow For example we need store10V 1 5 Ain the storage location 1 and bring up the parameter from storage location 1 1 Press the SET button to switch to the voltage value setting voltage value of 10 00 V press SET button again to save the voltage value 2 Press the SET button to switch to the current value setting current value of 1 500 A press SET button again to save the current value 3 Press the SET button to switch to the SA 0 press the or button to B3606DC DC NC buck module select the storage location here we need to adjust to the SA 1 press OK button to store the 10 V 1 5 A in the storage location 1 4 Press the SET button to switch to Lo 0 press the button to select the storage location which the parameter need to bring up here we need to adjust to the Lo 1 then press the OK button to bring up the parameters of storage location 1 5 This module has a total of 10 groups of storage location of 0 9 each storage location can be arbitrarily set the voltage and current value and each location is independent of each other 5 2 4 Enable the function 2 after output it
5. current power and capacity and other parameters in real time 3 2 6 Automatic manual switch to display voltage current power capacity and other parameters 3 2 7 With OUT CV and CC indicator you can view real time the work status 3 2 8 The module can set whether to automatically output after power on 3 2 9 Can easily save the current set of voltage and current values 3 3 Technical data Item Parameter The modular nature Non isolated Buck BUCK Input Voltage 6V 40V Output Current 0 Output voltage 0 36V Conversion efficiency 92 max Frequency 150KHz Short circuit protection Constant Current B3606DC DC NC buck module Operating Temperature 40 C 85 C Control method Digital control LED display The voltage regulator display resolution 0 01V The minimum resolution of power Display 0 001W The current regulator display resolution 0 001A The minimum resolution of capacity 0 001AH Output Ripple lt 50mV Weight 116g Dimensions W H D 80x66x33 mm 3 1 Technical data 4 Instrument Introduction 4 1 Structure Description Item Introduction Item Introduction 1 Positive input 5 Indicator of work status 2 Negative input 6 Negative output 3 LED 7 Positive output 4 Button 4 1 The introduction of B3606 3 B3606DC DC NC buck module 4 2 Display Introduction Display Introduction 00 00 Vol
6. sted 2 2 Check package contents Contents of the case are as bellows if the content does not match with the packing list or the instrument is damaged please contact us B3606 DC DC NC buck module 1pc Accessories User manual pdf 1pc 2 3 Check the machine If the machine was damaged did not work properly or failed to pass performance tests please contact your dealer or our company 3 Summary 3 1 Brief introduction B3606 is a fully digital display NC buck module Small size high power high efficiency and stable Join the High Speed Microcontroller precise B3606DC DC NC buck module measurement and calculation you can precisely regulate the output voltage and current built in 10 groups of memory locations can be stored and call up the parameters at any time The module is very easy to use Equipped with a four LED digital tube you can display the voltage current power capacity and other parameters in real time Meanwhile the machine has automatically output after power auto rotate functions The functions can be turned on or off according to use 3 2 Main function 3 2 1 The use of advanced microprocessors can be precisely regulated output voltage and current 3 2 2 With save function can store 10 sets of parameters and can freely store recall 3 2 3 Digital display easy to use 3 2 4 With a constant voltage constant current status 3 2 5 Using four high brightness LED can display the output voltage
7. tage 00 00 40 00V 0 000 Current 0 000 6 000A 000 P0 00 P00 0 Power value the unit is W the position of the decimal point is changed with power For example P 123 represents 0 123 W P1 23 represents 1 23 W P12 3 represents 12 3 W P102 represents 102 W 000 00 C00 0 Capacity value the unit is AH the position of the decimal point is changed with capacity For example C 123 represents 0 123AH C1 23 represents 1 23AH C12 3 represents 12 3AH C123 represents 123AH 0 Special function 0 1 Special function1 2 Special function2 y Open the special function n Close the special function SA represents 0 9 Save the parameters to the store location 0 9 Lo represents 0 9 Bring up the parameters from storage location 0 9 Save the parameter Restore factory settings 4 2 The display introduction of B3606 5 Operation The module has two kinds of usage one is simple mode another is fully functional mode The default is simple mode if you need fully functional mode you can open it by yourself 5 1 Simple mode B3606DC DC NC buck module 5 1 1 Connect input and output properly you should guarantee that the input voltage is in the range of requirement It is forbidden to reverse connection or it will be burnout The input voltage must be higher than the output voltage of 1 5V or more
8. urate regulation press the button for a while can regulate quickly Under the output state press OK button can switch display parameters such as voltage current power and capacity press the button for 3 seconds will automatically take turns to display press OK button for a while again will 5 B3606DC DC NC buck module cancel automatic take turns to display In the output state the and button is invalid 5 1 5 Under the output state press the SET button to close the output 5 2 Fully functional mode This module has three special functions the default is closed if necessary you can open them by yourself Function 0 After electricity it will output automatically Function 1 Save and bring up the parameters display the power and capacity Function 2 Take turns to show the parameters after output Automatically 5 2 1 Open close method Press the OK button for while then electricity the LED will take turns to show among 0 1 and 2 When displaying 0 release the OK button it will open or close the function 0 When displaying 1 release the OK button it will open or close function 1 When displaying 2 release the OK button it will open or close function 2 After releasing the OK button the y displays in the digital tube indicates that you have already open the current function the n means that you have closed the current function 5 2 2 Enable the function 0 it will