1. User manual DEHACO NANO v2 0 en oct 2010 page 11 DEHACO B V A Kruisbaak 25 2165 AJ Lisserbroek NL a Be P O Box 189 2160 AD Lisse NL Q Tel 31 0 252 417 950 fax 418 531 D H i CO www dehaco nl info dehaco nl CE Declaration of conformity ACCORDING TO ANNEX II 1 A OF THE MACHINE DIRECTIVE 2006 42 EC WE Demto B V Steurgat 3a NL 4251 NG WERKENDAM DECLARE ENTIRELY WITHIN THEIR OWN AREA OF RESPONSIBILITY THAT THE PRODUCT Brand DEMTO Model NANO Type DM DDR NA Serial number TO WHICH THIS STATEMENT APPLIES IS IN ACCORDANCE WITH THE PROVISIONS OF THE FOLLOWING DIRECTIVES Machine Directive 2006 42 EC Low voltage Directive 2006 95 EC EMC Directive 2004 108 EC AND IN ACCORDANCE WITH THE FOLLOWING STANDARDS AND OR OTHER NORMATIVE DOCUMENTS EN ISO 12100 1en 2 Safety of machinery EN ISO 14121 1 Risk analysis NEN 5509 User manuals DRAWN UP AT Werkendam date 09 12 2009 DEMTO B V A K J R Horden User manual DEHACO NANO v2 0 en oct 2010 page 12
2. DEHACO B V A Kruisbaak 25 2165 AJ Lisserbroek NL AC P O Box 189 2160 AD Lisse NL rd Tel 31 0 252 417 950 fax 418 531 D H R CO www dehaco nl info dehaco nl User manual DEHACO NANO NEBULISER Specifications Safety Use Maintenance ATTENTION es All persons involved in the initiation operation maintenance and repair of this product should receive a copy of these instructions User manual DEHACO NANO v2 0 en oct 2010 page 1 DEHACO B V A Kruisbaak 25 2165 AJ Lisserbroek NL a yd P O Box 189 2160 AD Lisse NL Tel 31 0 252 417 950 fax 418 531 www dehaco nl info dehaco nl Index Te MOU CHOI ANE AE EEEE E EREE E aeons E TEE E EE EE 3 Zs DESCHID UO e a A E EE AE A E E E AA E 4 UCTS USO eana E EA 4 4 Technical specification S essnee ea Eina Ena aANT ENEE 5 OD I OLY S E P TE EET E EE E EEEE 5 6 Re 6 f2 0 ee eee ee ee O eee eee T Fa TINS ON a A A A E E A SSE OWC AINO NC UNION e E E 8 TN Ne UNOR eree EEEE E 9 10 Prevention of legionehlla cc cccccccceececeececeseeceeeeceeeeseeesseecsueessueeseaeessaseseueesueeseeeeseeees 9 TE MAIRENA A E E 10 12 MFOUIDICSS NOON eea E E E E 10 13 ENG OF economic eE ereenn aa E e 11 AE EE A E E E O E A AE A E E E T EN EE E E T E E 11 E A AS E E Se E E E E E E E A ET E A 11 CE Declaration Of CONTON V sictorcccce0caseadsnaraeeeseecneavesdaemeeracaddeneveaaeansxdscdote pncaensesdcoaneeeusds
3. DEHACO B V A Kruisbaak 25 2165 AJ Lisserbroek NL a Ba P O Box 189 2160 AD Lisse NL Tel 31 0 252 417 950 fax 418 531 D H i CO www dehaco nl info dehaco nl 11 Maintenance WARNING Before carrying out any inspection maintenance or reparation always remove the plug from the socket Daily e Inspect the unit visually for damage Repair damage however slight immediately or have it repaired This is for your safety and to maximise the lifetime of the machine e Also inspect the electricity cable lf damaged remove it immediately and have it repaired Your safety comes first e Keep the nebuliser clean This reduces the risk of accidents and works more comfortable ATTENTION Clean carefully Never use a high pressure cleaner 12 Trouble shooting WARNING Repairs must be carried out by qualified personnel only Use only original spare parts This guarantees the safety of the equipment N 1 The fan bearings are noisy not running smoothly Replace the bearings Mount using a liquid thread locker 2 The ventilator will not start No voltage Turn on power turn on regulator replace fuse Voltage present Carbon brush is worn replace the carbon brush 3 Thermal protection stalls Clean Replace the bearings Replace the windings 4 Nebuliser is not receiving water Check the water flo
4. 12 Translation of Original user manual Copyright 2010 Dehaco BV All rights reserved No part of this publication may be reproduced or transmitted in any form or published in any form or means electronic mechanical photocopying recording or otherwise without the prior written permission of Dehaco BV This also applies if necessary accompanying drawings and diagrams Dehaco B V reserves the right to change parts at any time without prior or immediate notice to the customer The contents of this manual can also be changed without prior notice For information concerning establishment maintenance and repair this user manual does not provide please contact the technical department of your supplier This user manual has been made with all possible care but Dehaco B V can not accept responsibility for any errors in this manual or the consequences thereof 10 2010 User manual DEHACO NANO v2 0 en oct 2010 page 2 DEHACO B V A Kruisbaak 25 2165 AJ Lisserbroek NL a Se P O Box 189 2160 AD Lisse NL Tel 31 0 252 417 950 fax 418 531 D H i CO www dehaco nl info dehaco nl 1 Introduction Many thanks for the purchase of the DEHACO NANO nebuliser Consequently you own a state of the art unit that you if used correctly can use for years without breakdowns The following symbols and attention texts are used in this manual ATTENTION E This text provides instructions tips and information
5. 15x550x350 mm SERIE NR hee NG Water connector Gardena quick release LUCHTCAPACITEIT STAND f eee Water flow rate 0 90 Itr hr continually varable Pen re ec ae _ Motorspeed 3 positions 600 900 1 400 rom MANUFACTURER DEMTO BV WERKENDAM HOLLAND Air output 1 900 2 900 4 500 m hr Safety device thermal protection 5 Safety WARNING Almost all accidents are a result of loss of concentration inattention negligence wrong estimations Work calmly and concentrated You have been warned ATTENTION You must follow the safety instructions in this user manual under all circumstances This also applies to the instructions of local authorities WARNING There exists imminent danger of bodily injury and damage to the machine as a result of inexperienced incompetent or careless use Keep bystanders at a safe distance when you work User manual DEHACO NANO v2 0 en oct 2010 page 5 DEHACO B V A Kruisbaak 25 2165 AJ Lisserbroek NL a Bea P O Box 189 2160 AD Lisse NL Tel 31 0 252 417 950 fax 418 531 D H i CO www dehaco nl info dehaco nl ATTENTION Wear always the required Personal Protective Equipment PPE that is to say at least safety footwear helmet goggles and worker s gloves General safety rules a Ensure that your wo
6. for optimal use WARNING This text provides information relating to safety Non compliance can result directly in physical injury and or damage to the machine This manual is intended to familiarize you with the operation to give instructions for safe use and guidelines for regular maintenance The Dehaco NANO nebuliser has been delivered completely assembled and tested ready for use The delivery includes a the machine and b this manual Check immediately at the delivery if the machine is complete and intact If parts are missing or if there is transport damage contact directly your supplier This user manual the name plate and the stickers on the nebuliser contain important information and are as such part of the delivery In case of damage or loss these should be replaced at once All these spare parts can be delivered subsequently by Dehaco BV ATTENTION E Make sure that you are acquainted with the contents of this manual before _ starting the activities so that you can use the machine in the best way User manual DEHACO NANO v2 0 en oct 2010 page 3 DEHACO B V A Kruisbaak 25 2165 AJ Lisserbroek NL a Ba P O Box 189 2160 AD Lisse NL Tel 31 0 252 417 950 fax 418 531 D H i CO www dehaco nl info dehaco nl 2 Description The Dehaco NANO has been developed for small scale applications The NANO is a co
7. mpact unit used to produce a very fine water spray to control dust during indoor demolition and renovation projects A small rapidly rotating disc supplies a fine water spray which is distributed by the fan By an adjustable water supply and a three speed fan the water spray and the spreading can be adapted to your specific situation WARNING Never touch the nebuliser during operation for a correct operation it could not be shielded 100 ATTENTION E Prevent contamination of the unit Previously provide a clean water hose rinsed and a quick release 3 Intended use The DEHACO NANO nebuliser s meant to produce a water spray and to disperse this spray to bind it with dust and reducing the amount of dust in the air during demolition and renovation projects s meant to be used with clean tap water Is meant for use in bigger indoor spaces and smaller outdoor spaces WARNING The DEHACO NANO is NOT suitable for use in explosion hazard areas DEHACO B V A Kruisbaak 25 2165 AJ Lisserbroek NL a Se P O Box 189 2160 AD Lisse NL Tel 31 0 252 417 950 fax 418 531 D H fl CO www dehaco nl info dehaco nl 4 Technical specifications WVoltage 220 V 50 Hz POWED eeeseseseeeeeeeees 230 W CE BR Isolation F IP 55 jet proof e F Dimensions Ixhxw 5
8. rk area is clean and well lit An untidy and or poorly lit work area can result in accidents b Do not use the equipment in areas where there is an explosion hazard Electrical equipment produces sparks which may ignite the dust or vapours c Keep children or other persons away from the area when the equipment is in use You may lose control of the equipment if you are distracted d Do not use any equipment if you are tired or under the influence of drugs alcohol or medication A moment of inattentiveness when using the equipment can result in serious injury and or damage to the equipment or surroundings e Remove all loose tools before you turn on the machine f Wear suitable clothing Do not wear any loose clothing or jewellery Keep hair clothing and gloves out of the way of moving parts Loose clothing long hair and jewellery may interfere with moving parts g Ensure damaged parts are repaired before use Many accidents are due to poor maintenance h In addition to the general rules given above you should also be aware of local working conditions and regulations User manual DEHACO NANO v2 0 en oct 2010 page 6 DEHACO B V Kruisbaak 25 2165 AJ Lisserbroek NL P O Box 189 2160 AD Lisse NL Tel 31 0 252 417 950 fax 418 531 www dehaco nl info dehaco nl 6 Storage The following actions should be taken if nebuliser will not to be used for a long time e Clean the unit e Perform maintenance according
9. to the schedule Store the unit in a clean dry area and cover it with a canvas 7 Transport WARNING Avoid damage Always be careful when transporting the Dehaco nebuliser During transport the nebuliser should always be secured with enough tension straps User manual DEHACO NANO v2 0 en oct 2010 page 7 DEHACO B V Kruisbaak 25 2165 AJ Lisserbroek NL D P O Box 189 2160 AD Lisse NL Tel 31 0 252 417 950 fax 418 531 www dehaco nl info dehaco nl 8 Switching the unit on ATTENTION Before connecting the water hose first flush it out in order to avoid dust or grit in the hose and that the spray unit will become dirty and or obstructed a waterflow controller b water connection c on off switch d reset button thermal protection e power cable 220V f speed control fan 1 Place the Dehaco NANO close enough to the work area but not so close that it gets in your way or can be hit by falling objects Turn off the water flow a Clean the water hose connector b and connect it Place the plug in the plug socket Switch on the spray unit c Adjust the desired speed of the fan f Open the waterflow controller a carefully into desired position os wN 7 Turn the nebuliser in the desired angle Using a different order for switching on the unit is not harmful but not very practical if you open the water flow con
10. troller before switching on the unit it will start leaking the fan may be put on the position 0 when the nebuliser is turned on this will cause no damage the nebuliser may run dry this will not cause damage User manual DEHACO NANO v2 0 en oct 2010 page 8 DEHACO B V Kruisbaak 25 2165 AJ Lisserbroek NL P O Box 189 2160 AD Lisse NL Tel 31 0 252 417 950 fax 418 531 www dehaco nl info dehaco nl DEHACO PRUNG the unit off Turn off the water supply 2 WAIT UNTIL NO MORE WATER COMES OUT OF THE WATER SPRAY 3 Turn off the nebuliser and put out the plug from the socket 4 Disconnect the water hose from the NANO 5 Turn the nebuliser 45 forward photo so that the remaining water runs out 10 Prevention of legionella Legionella is a bacterium that can cause legionnaire s disease Infection can occur by inhaling the bacterium through very small water droplets dispersed in the air showers spray units or whirlpools The bacterium can grow in standing water with a temperature of 20 50 C Simple basic prevention measures are e Use always clean tap water e Flush out the water hose before connecting it to the nebuliser e Empty the DEHACO NANO carefully after use See above ATTENTION eS You the user are responsible for the prevention of legionella You have been warned User manual DEHACO NANO v2 0 en oct 2010 page 9
11. w the control valve clean the filter User manual DEHACO NANO v2 0 en oct 2010 page 10 DEHACO B V A Kruisbaak 25 2165 AJ Lisserbroek NL a Be P O Box 189 2160 AD Lisse NL Tel 31 0 252 417 950 fax 418 531 D H i CO www dehaco nl info dehaco nl 13 End of economic lifetime ATTENTION Get informed at the local authorities about the current requirements and guidelines for responsible discharging Electrical tools accessories and packaging have to be reused in an environmentally sound manner 14 Warranty A warranty applies to the Dehaco NANO for a period of six months from the time of delivery in accordance with the Metaalunie conditions Within this period and subject to an assessment made by Dehaco BV material faults and factory faults will be repaired free of charge Transport and or travel costs are for the account of the customer The warranty does not apply to defects resulting from overworking the equipment using the equipment for activities other than for those which it is intended poor maintenance not properly following up the information given in these instructions using the equipment by persons not qualified to do so repairing the equipment with non original spare parts adapting the equipment without the written consent of Dehaco BV 15 Spare parts All spare parts required for maintenance or repair are available through your supplier

Download Pdf Manuals

image

Related Search

Related Contents

CTB Series - Scale Manuals    Anritsu PowerXpert and USB Power Sensors User Guide  Philips GoGear SA3414 User's Manual  RL-H3A/B - ToppTopo A/S  Skip PrivateArea BBM User Manual  ZyXEL NBG-419N User's Manual    Definitive Technology 60 Speaker User Manual  Extron electronic Extron Electronics Switch DMS 3200 User's Manual  

Copyright © All rights reserved.
Failed to retrieve file