Home

ReFreeX user manual for H411V4

image

Contents

1. metreex E A H411V4 User manual ID MICHELETTI IMPIANTI doc H411V4 Contents Contents 1 Parameter list 2 Parameter remarks 3 Alarm list 4 Slave alarm list 5 Button list 6 Led list 7 Soft command list 8 How to 9 Shortcut list 10 Led and push button location 10 The IATEX source of this document has been automatically produced by 4 13 22 on 2015 11 27 page 2 10 ID MICHELETTI IMPIANTI doc H411V4 1 Parameter list Rem Parameter Description S__ St_ _t0 _db dbd _tH _tL _td SMM SMd SA_ 1 SAH dA6 dA7 2 dA8 SAh dAF SAo 3 rrH rrh 6 YYb rYY rYd 7 dYO dY2 _nY 9 dY3 dY4 dY5 rYh dYF rYo rYA rA_ rAH _nA 10 11 dA4 dA5 rAh rAF rAo 10 nU nUS nUr nE_ nEH Pd PdM PdS Pd2 Functions about storage Functions about storage temperature storage room temperature dead band differential safety maximum room temperature safety minimum room temperature safety temperature differential storage room humidity differential Functions about air renew during storage enable air renew during storage reset timers immediate delay before first air renew on time duration in the air renew cycle period of air renew cycle enable forced air renew by keyboard short cut forced air renew duration start stop forced air renew Functions about ripening Enable ripening functions and short cut enable ripening functions reset timers enable tog
2. oFF oFF oFF oFF oFF oFF oFF oFF oFF oFF oFF oFF oFF oFF oFF oFF oFF 55 0 C 0 0 gauge bar 55 0 C 999 0 K 55 0 C 0 0 dd hh mm ss 0 d hh mm ss ooo OS am en o 2 d hh mm ss d hh mm ss The IATEX source of this document has been automatically produced by 4 13 22 on 2015 11 27 page 5 10 CD MICHELETTI IMPIANTI doc H411v4 Rem Parameter Description Minimum Maximum Default Unit On2 depressure fan 2 oFF _on oFF On3 depressure fan 3 oFF _on oFF I1A Analog inputs auxiliary master 1 raw data IA1 analog input 1 0 65535 0 IA2 analog input 2 0 65535 0 IA3 analog input 3 0 65535 0 IA4 analog input 4 0 65535 0 IA5 analog input 5 0 65535 0 IA6 analog input 6 0 65535 0 IA7 analog input 7 0 65535 0 IA8 analog input 8 0 65535 0 lld Digital input Id1 digital input 1 oFF _on oFF Id2 digital input 2 oFF _on oFF Id3 digital input 3 oFF _on oFF Id4 digital input 4 oFF _on oFF Id5 digital input 5 oFF _on oFF O1A Analog output OA1 analog output FAN 0 255 0 OA2 analog output I out 0 255 0 Old Digital output Od1 digital output 1 oFF _on oFF Od2 digital output 2 oFF _on oFF Od3 digital output 3 oFF _on oFF Od4 digital output 4 oFF _on oFF Od5 digital output 5 oFF _on oFF Od6 digital output 6 oFF _on oFF I2A Analog inputs auxiliary master 2 raw data IA1 analog input 1 0 65535 OF IA2 analog input 2 0 65
3. ethylene analog input 7 low pressure analog input 8 Digital input digital input 1 ethylene hardware safety digital input 2 evaporator hardware safety digital input 3 heating hardware safety digital input 4 unused digital input 5 phase 1 software safety Analog output analog output FAN analog output I out Digital output digital output 1 refrigeration solenoid digital output 2 steam producer digital output 3 air renew digital output 4 ethylene digital output 5 evaporator digital output 6 heating alarm eventually connected to relay nr 2 Machine status door fully open door fully closed door safety door is presumed to be closed combining history of door closure and safety button B8 is pressed button B7 is pressed safety of depressure fan 1 safety of depressure fan 2 safety of depressure fan 3 actual set point low pressure LP refrigerant saturation temperature corresponding to the low pressure refrigerant overheating at the evaporator outlet product average temperature ripening status O off 1 immediate delay 2 t1 3 t2 4 t3 5 t4 6 t5 ripening timer in countdown mode ethylene status O off 1 immediate delay 2 waiting for temperature 3 first on 4 first over 5 following on 6 following pause 7 ended 8 forced ethylene timer in countdown mode remaining following ethylene cycles of injection including the one eventually running ripening air rene
4. 0 255 1 F3t label text during rotation 000 yyy Av F3E duration of value display during rotation 0 255 4 Eb _ Functions about buzzer EbH enable buzzer 0 1 1 Eh_ Functions about keyboard Ehc B6 action on the curtain O unrolls 1 rolls 0 1 0 ERD Functions about slave default EFF reload slave default parameters from EEPROM at next restart 0 1 0 2 Parameter remarks Nr Remark During off time counters continue to count and output is disabled At reset command they stop and their value is reset They are restarted by on command The minus sign on display means that you already reset timers The period of each cycle includes on time off time that is the overall duration of the cycle 3 The oFF command disables the ripening functions and enables the storage The ripening timers continue however to run also if their output is disabled To restart the ripening timers please do the rES reset command The on command enables the ripening functions without restarting the timers To begin a new ripening cycle please do the rES command The minus sign on display means that you have already reset the timers 4 At the end of the ripening cycle the temperature is set to t5 until the manual reset of the ripening cycle 5 The stop command resets forced operation counter N 6 In case of probe control ethylene timers and settings are not used You can still activate forced injections In case of disabled probe rYY
5. b3A is off 20 Caution Low overheating causes liquid return and compressor damage 21 Caution Short duty cycle reduces valve life 22 Caution Low overheating causes liquid return and compressor damage 23 Caution High adaptation speed causes swing in the suction line and damage to the compressor 24 The low temperature differential is fixed and alarm status stops at 0 2 C above the set point 25 The high temperature differential is fixed and alarm status stops at 0 2 C under the set point 26 Passing from stand by to on and at power on there is a 5 second delay spent in a virtual stand by 27 When keyboard is locked it is possible to read parameters but is not possible to modify them To exit the lock it is necessary to write the password doc H411V4 3 Alarm list Display Alarm A01 low temperature Low temperature limit has been reached A02 high temperature High temperature limit has been reached A03 ethylene alarm The ethylene safety device has disconnected A04 evaporator alarm Evaporator thermal relay or other evaporator safety device has disconnected A05 heating alarm The heating safety device has disconnected A06 door open Time limit for door opening has been reached A07 phase alarm Heating overload thermal relay disconnected or missing mains phase manual reset A08 fan 1 alarm Depressure fan overload thermal relay disconnected A09 fan 2 alarm Depressure fan overload thermal relay disconnected A10 fan 3 alarm
6. dd hh mm ss oFF 30 oFF on on on on 30 oFF oFF oFF oFF on 8 0 10 0 o 0 0 oFF on on 0 0 on on on 0 0 oFF oFF oFF 0 0 on on on 0 0 on 0 0 oFF 0 0 on 2 0 14 0 30 00 oFF dd hh mm ss d d hh mm ss gt K gauge bar dd hh mm ss dd hh mm ss I R RE NES SS sg Zn Se eC dd hh mm ss The IATFX source of this document has been automatically produced by 4 13 22 on 2015 11 27 page 4 10 ID MICHELETTI IMPIANTI doc H411V4 Rem Parameter Description dF_ dF6 h Bez hL_ Dik hLH hLP hLI hLe hLO AL IA1 IA2 1A3 1A4 IA5 IA6 IA7 1A8 Id1 Id2 Id3 Id4 Id5 OA _ OA1 OA2 Od Od1 Od2 Od3 Od4 Od5 Od6 Od7 Os Ido Idc Idh IdP Ib7 Ib8 Inl In2 In3 Oso OS1 OS2 053 054 OSr OSt OSY OSU OnY OSb OSv OnA OSA OSX OSd OSE LLA OSn Odo Odc OdF OdL Ocu Ocr Onl Delay from previous stop delay from request to activation of OUT 6 heating Functions about keyboard Keyboard lock keyboard lock unlock keyboard lock unlock password extend lock to light operation extend lock to curtain operation extend lock to door operation Functions about input output and machine state read only Analog inputs analog input 1 temperature analog input 2 temperature analog input 3 suction temperature analog input 4 temperature analog input 5 humidity analog input 6
7. door and trigger man in room alarm B8 curtain Remote button near to the depressure box inside the room switch on and off the curtain unrolling The IATFX source of this document has been automatically produced by 4 13 22 on 2015 11 27 page 8 10 CD MICHELETTI IMPIANTI doc H411v4 6 Led list Led Function L1 cooling On during cooling L2 depressure On when all depressure fans are running L3 humidity On when humidification is active L4 air renew On during air renew blinking slowly during pause and delay L5 heating On during heating blinking slowly during activation delay L6 ethylene On during ethylene injection blinking slowly when waiting for three events temperature threshold _tY following injections _nY first air renew rYA L7 light On when lighting is on blinking slowly during deactivation delay 7 Soft command list Soft command Function 8 How to How to Switch between on and stand by Program the menu Show or change temperature set Reset timers Enter ripening mode Enter storage mode Door operation Curtain operation 9 Shortcut list Function Keep pressed B3 button to activate and deactivate stand by In stand by every output is disabled except light leds from L1 to L6 blink timers continue to count Keep pressed B6 to enter the menu Navigate up and down with B2 and B5 Select the submenu by B6 Change the parameter by B2 and B5 press B6 to confirm or B4 t
8. press shortly B6 or B8 to unroll B4 to roll B1 to stop and again B1 to exit curtain mode During curtain operation every output is disabled The display shows Cur with the curtain idle Unr during unrolling and rOL during rolling Buttons to press Shortcut description keep pressed 5 seconds Bo B3 Enter ripening mode Bo B1 Enter storage mode B6 B4 Activate the keyboard for curtain operation Bo B2 Force an immediate air renew B6 B5 Force an immediate ethylene injection The IATEX source of this document has been automatically produced by 4 13 22 on 2015 11 27 page 9 10 ID MICHELETTI IMPIANTI 10 Led and push button location LI L2 L3 L4 L5 L6 L7 JER JE JR JR E The IATEX source of this document has been automatically produced by 4 13 22 on 2015 11 27 page 10 10
9. 535 0 IA3 analog input 3 0 65535 0 IA4 analog input 4 0 65535 0 IA5 analog input 5 0 65535 0 IA6 analog input 6 0 65535 0 IA7 analog input 7 0 65535 0 IA8 analog input 8 0 65535 0 12d Digital input Id1 digital input 1 oFF _on oFF Id2 digital input 2 oFF _on oFF Id3 digital input 3 oFF _on oFF Id4 digital input 4 oFF _on oFF Id5 digital input 5 oFF _on oFF O2A Analog output OA1 analog output FAN 0 255 0 OA2 analog output I out 0 255 0 O2d Digital output Od1 digital output 1 oFF _on oFF Od2 digital output 2 oFF _on oFF Od3 digital output 3 oFF _on oFF Od4 digital output 4 oFF _on oFF Od5 digital output 5 oFF _on oFF Od6 digital output 6 oFF _on oFF ESS Functions about slave preferences Ed Functions about network address EdS slave address for local network communication 1 254 1 EY Functions about display EYY input to show on display O average temperature 1 AN1 2 AN2 0 255 0 EYS value set by shortcut during ripening 0 _t0 1 _t1 5 _t5 6 current 0 6 6 EYr enable display rotation O off 1 all 2 selected 0 2 0 EO Functions about display rotation when EYr 1 EOd duration of label display during rotation 0 255 al ff EOE duration of value display during rotation 0 255 2 El Functions about display rotation when EYr 2 repeated for each parameter Eld duration of label display during rotation 0 255 1 Elt label text during rotation 000 yyy rM E1E duration of value display d
10. Depressure fan overload thermal relay disconnected A11 man in room alarm Somebody remained trapped inside the room A12 RTC memory loss Memory loss of real time clock RTC timer reset A13 EEPROM invalid EEPROM invalid A14 EEPROM read start EEPROM read start failure A15 EEPROM read end EEPROM read end failure A16 EEPROM write start EEPROM write start failure A17 EEPROM write end EEPROM write end failure A18 EEPROM write max EEPROM failure reached the maximum number of writing attempts 4 Slave alarm list Display Alarm A96 slave EEPROM Failed write operation onto the slave EEPROM A97 out of range The slave address EdS might be out of the master range the latter going from 1 to PdS A98 no link The slave does not receive any message from the master A99 lost link The slave lost the communication with the master 5 Button list Push button Function Bl esc stop silence Exit without saving from any menu door curtain stop alarm buzzer silence B2 up open Up navigation in the menu door opening B3 on stand by Toggle between on and stand by B4 left light roll Left navigation in the menu switch the light on and off roll the curtain B5 down close Down navigation in the menu door closure B6 right menu set unroll Right navigation in the menu display and modify set point enter the menu unroll the curtain B7 light door alarm Remote button near to the door inside the room switch on the light open the
11. atic closure delay of door automatic closure enable depressure refrigeration and other output when door is not closed enable door opening after first ethylene injection and before first air renew Functions about light switch on the light during door operation switch on the light when the door is open and off when closed switch off the light automatically if it has been switched on from outside delay of light automatic switch off Functions about curtain operation enable curtain operation from keyboard keyboard in curtain mode enable curtain operation when door is not open enable curtain operation when light is off Functions about electronic expansion valve Functions about electronic expansion valve preference enable electronic expansion valve Functions about electronic expansion valve temperature wanted overheating similar to Danfoss thermostatic overheating spring regulation maximum pressure allowed in the suction line similar to Danfoss MOP Functions about electronic expansion valve timing on off duty cycle duration on duty cycle duration at refrigeration start set to 0 for previous stop value on duty cycle adaptation speed low value for slow adaptation and small swinging Functions about probe calibration Probe nr 1 calibration offset use probe to calculate product average temperature use probe for safety temperature use probe for alarm temperature Probe nr 2 calibration offset use probe to calculate product a
12. d hh mm ss TE dd hh mm ss Ze dd hh mm ss TC 10 ppm 10 ppm dd hh mm ss AG dd hh mm ss 0 1 0 00 00 30 00 12 00 00 _on 30 00 oFF oFF oFF 8 1 0 00 00 30 00 12 00 00 dd hh mm ss dd hh mm ss dd hh mm ss dd hh mm ss dd hh mm ss dd hh mm ss dd hh mm ss on 30 00 oFF dd hh mm ss The IATEX source of this document has been automatically produced by 4 13 22 on 2015 11 27 page 3 10 ID MICHELETTI IMPIANTI doc H411V4 Rem Parameter Description 12 13 14 15 16 17 18 15 15 20 21 22 23 24 25 26 Pg Pgg A Pjh Pij PO_ PO2 oe cOh cOF cOd cOH cCd cOU cOY cl cIO clH clo cld cc cch ccc ccO ccl vP vPH vt_ vtt vtU vd vdi vd2 vdd b1_ bic blA b1S bIL b2_ b2C b2A b2S b2L b3_ b3C b3A b3S b3L b4_ bac b4A b4S b4L b5_ b5C b5A b6_ b6C b6A b7_ b7C b7A Lt LtL LtH Ltd Lo_ Loo Functions about saving preferences save actual preferences as program 1 99 Functions about loading preferences enable preferences load by keyboard short cut load preferences as program 0 99 0 is factory setting Output assignment assign out 2 relay to O alarm 1 humidifier Functions about door and light Functions about door enable door operation from keyboard enable door flashing light in case of alarm delay between pushing button and door opening or closure enable door autom
13. gling between ripening and storage by keyboard short cut Functions about ripening temperature and humidity immediate delay before starting ripening ripening temperature nr 1 duration of temperature nr 1 ripening temperature nr 2 duration of temperature nr 2 ripening temperature nr 3 duration of temperature nr 3 ripening temperature nr 4 duration of temperature nr 4 ripening temperature nr 5 ripening humidity ripening humidity differential Functions about ethylene enable ethylene injection reset timers use ethylene probe to control injections ripening ethylene concentration ripening ethylene concentration differential immediate delay before starting ripening minimum temperature before injecting ethylene first ethylene injection duration number of following ethylene cycles of injection delay between first ethylene injections end and following cycles on time duration of following ethylene injection cycles period of following ethylene injection cycles enable forced ethylene injection by keyboard short cut forced ethylene injection duration start stop forced ethylene injection first ethylene injection performed but air renew not yet Functions about air renew during ripening enable air renew cycles during ripening reset timers number of air renew cycles delay between first ethylene injection end and first air renew end on time duration in the air renew cycle period of air renew cycle enable forced air rene
14. is used to control curtain string motor when curtain is idle 7 To synchronize ethylene injection and ripening start set dYO _d0 8 First ethylene injection is delayed until room temperature reaches _tY _tY has no effect over following ethylene injections 9 To synchronize the beginning of further ethylene injections and air renews set dY3 dA3 10 To synchronize the cycles of further ethylene injections and air renews set dY3 dA3 11 Set by the microcontroller can be manually overwritten 12 Door operation disables every other keyboard operation 13 The first pressure of push button inside the room near the door switches on the light the second one opens the door the third one activates the man in room alarm 14 During the delay the flashing light is on 15 For your safety do not modify this parameter This setting is supposed to be used just in case of emergency or testing The IATEX source of this document has been automatically produced by 4 13 22 on 2015 11 27 page 7 10 ID MICHELETTI IMPIANTI Nr Remark 16 No action if the light is switched on from inside the room 17 Curtain operation disables every other operation keyboard operation 18 For safety reason door operation is disabled when curtain is enabled Unrolling can be started also by a push button located near the depressure box inside the room 19 When off the refrigeration solenoid is steadily on during cooling as long as overheating is higher then vtL or
15. o go back without saving The changes will have effect after the exit from programming pressing B4 repeatedly Press B1 to exit immediately without saving any parameter Press shortly B6 the display shows the current set point change it by B2 and B5 and confirm it by B6 As alternative enter the menu program as explained above modify the parameter _t0 then confirm it For the resettable controls in the menu program confirming rES then confirming on or oFF has the joint effect of resetting timers and going into the enabled or disabled status Keep pressed B6 B3 As alternative enter the menu program as explained above set the parameter rrH reset it in case it is a new ripening then confirm it Keep pressed B6 B1 As alternative enter the menu program as explained above set to oFF the parameter rrH then confirm it Push B2 to open B5 to close and B1 to stop If you are inside the room and the door is closed press B7 once to switch on the light press again to open the door and again to trigger the man in room alarm During door operation display shows OPE or CLO By default when the door is open the light is on and every other output is off By default door operation is disabled after the first ethylene injection and before subsequent air renew For safety reason the curtain can be operated only when the door is fully open and the light is on To activate the keyboard for the curtain keep pressed B6 B4 then
16. rameter E7d duration of label display during rotation 0 255 1 E7t label text during rotation 000 yyy LP E7E duration of value display during rotation 0 255 0 E8 _ Functions about display rotation when EYr 2 repeated for each parameter E8d duration of label display during rotation 0 255 1 E8t label text during rotation 000 yyy X3 E8E duration of value display during rotation 0 255 0 EQ Functions about display rotation when EYr 2 repeated for each parameter E9d duration of label display during rotation 0 255 1 E9t label text during rotation 000 yyy ze EGE duration of value display during rotation 0 255 4 FO Functions about display rotation when EYr 2 repeated for each parameter FOd duration of label display during rotation 0 255 1 FOt label text during rotation 000 yyy LP FOE duration of value display during rotation 0 255 0 Al Functions about display rotation when EYr 2 repeated for each parameter Fid duration of label display during rotation 0 255 1 Fit label text during rotation 000 yyy F1E duration of value display during rotation 0 255 0 E20 Functions about display rotation when EYr 2 repeated for each parameter F2d duration of label display during rotation 0 255 1 F2t label text during rotation 000 yyy oh F2E duration of value display during rotation 0 255 0 F3_ Functions about display rotation when EYr 2 repeated for each parameter F3d duration of label display during rotation
17. uring rotation 0 255 4 Eg Functions about display rotation when EYr 2 repeated for each parameter E2d duration of label display during rotation 0 255 1 E2t label text during rotation 000 yyy X1 E2E duration of value display during rotation 0 255 4 Ess Functions about display rotation when EYr 2 repeated for each parameter E3d duration of label display during rotation 0 255 1 E3t label text during rotation 000 yyy SU E3E duration of value display during rotation 0 255 0 The IATEX source of this document has been automatically produced by 4 13 22 on 2015 11 27 page 6 10 ID MICHELETTI IMPIANTI doc H411v4 Rem Parameter Description Minimum Maximum Default Unit EAB Functions about display rotation when EYr 2 repeated for each parameter E4d duration of label display during rotation 0 255 1 E4t label text during rotation 000 yyy X2 E4E duration of value display during rotation 0 255 4 E5 Functions about display rotation when EYr 2 repeated for each parameter E5d duration of label display during rotation 0 255 1 E5t label text during rotation 000 yyy rH E5E duration of value display during rotation 0 255 4 E6 Functions about display rotation when EYr 2 repeated for each parameter E6d duration of label display during rotation 0 255 1 E6t label text during rotation 000 yyy Et E6E duration of value display during rotation 0 255 0 EV Functions about display rotation when EYr 2 repeated for each pa
18. verage temperature use probe for safety temperature use probe for alarm temperature Probe nr 3 calibration offset use probe to calculate product average temperature use probe for safety temperature use probe for alarm temperature Probe nr 4 calibration offset use probe to calculate product average temperature use probe for safety temperature use probe for alarm temperature Probe nr 5 calibration offset use probe to calculate room humidity Probe nr 6 calibration offset use probe to calculate room ethylene Probe nr 7 calibration offset use probe to calculate suction pressure Functions about alarm and stand by Temperature alarm low temperature alarm set point high temperature alarm set point alarm delay On stand by status actual status stand by or on Functions about delays Minimum oFF oFF oFF oFF oFF oFF oFF oFF oFF oFF oFF oFF oFF oFF 0 0 0 0 oo 9 0 oFF oFF oFF 9 0 oFF oFF oFF 9 0 oFF oFF oFF 9 0 oFF oFF oFF 9 0 oFF 9 0 oFF 9 0 oFF 55 0 55 0 oFF Maximum 99 on 99 _on _on 194 4 20 15 _on 194 4 20 15 on on on on on 194 4 20 15 on on on on on 99 0 30 0 194 4 20 15 194 4 20 15 255 9 0 on on on 9 0 on on on 9 0 on on on 9 0 on on on 9 0 on 9 0 on 9 0 on 145 0 145 0 194 4 20 15 on Default oFF on Unit ns on
19. w by keyboard short cut forced air renew duration start stop forced air renew Functions about fans Functions about depression fans number of depression fans during storage number of depression fans during ripening Functions about evaporator fans force evaporator fans when refrigeration is off Functions about master preferences Functions about network address master address for global network communication number of slaves connected to this master number of auxiliary masters connected to this master Minimum 55 0 0 0 0 0 55 0 55 0 0 0 0 0 0 0 oFF 0 0 0 oFF 0 oFF Maximum 145 0 50 0 50 0 45 0 45 0 50 0 100 0 50 0 _on 194 4 20 15 194 4 20 15 194 4 20 15 _on 194 4 20 15 on on _on 194 4 20 15 45 0 194 4 20 15 45 0 194 4 20 15 45 0 194 4 20 15 45 0 194 4 20 15 45 0 100 0 50 0 _on _on 99 0 99 0 194 4 20 15 45 0 194 4 20 15 255 194 4 20 15 194 4 20 15 194 4 20 15 _on 194 4 20 15 on on _on 99 194 4 20 15 194 4 20 15 194 4 20 15 _on 194 4 20 15 on on 254 Default 12 0 0 0 0 2 21 0 10 0 0 2 90 0 5 0 oFF 0 30 00 12 00 00 Unit C K K AC C K dd hh mm ss dd hh mm ss dd hh mm ss on 30 00 oFF oFF on 0 16 5 4 0 00 00 15 5 1 0 00 00 14 5 0 14 5 0 14 5 90 0 5 0 oFF oFF 25 0 5 0 0 16 0 30 00 dd hh mm ss dd hh mm ss C dd hh mm ss C d
20. w status O off 1 waiting for ethylene 2 first pause 3 on 4 pause 5 ended 6 forced ripening air renew timer in countdown mode remaining air renew cycles including the one eventually running storage air renew status O off 1 immediate delay 2 on 3 pause 4 forced storage air renew timer in countdown mode auxiliary master 1 status O off 1 ok 2 check 3 reconnect 4 none 5 lost auxiliary master 2 status O off 1 ok 2 check 3 reconnect 4 none 5 lost actual alarm read only 0 means no alarm evaporator fan stopped by door opening or manual control door is opening door is closing door light is flashing room lighting curtain is unrolling curtain is rolling depressure fan 1 Minimum 0 oFF oFF oFF oFF oFF oFF oFF oFF oFF oFF oFF oFF oFF oFF oFF oFF oFF oFF oFF oFF 55 0 55 0 999 0 55 0 Maximum 194 4 20 15 _on 99 on on on 145 0 145 0 145 0 145 0 100 0 999 0 999 0 145 0 on on on on on 255 255 on on on on on on on on on on on on on _on _on _on 145 0 999 0 145 0 999 0 145 0 255 194 4 20 15 255 194 4 20 15 255 255 194 4 20 15 255 255 194 4 20 15 255 255 255 on on on on on on on on Default Unit 3 00 dd hh mm ss oFF 22 oFF Lon Zon 55 0 C 55 0 C 55 0 C 55 0 C 0 0 0 0 10 ppm 0 0 gauge bar 55 0 C