Home
        50 Gallon Skid Sprayer
         Contents
1.          ee KINOS 50 Gallon  Spraye rs vos    Model    KSUSOP6  User Manual    Read this manual for complete instructions          Need help  Call Kings Sprayers if you have any questions with this product   Technical service hours  Monday     Friday  8 00 a m      5 00 p m  ET    1 800 228 0905   info kingssprayers com    Model    KSU50P6    Table of Contents    Warranfy sereisas ninani aE a aaia a a Taaa Ranea  General Safety Information seis oeercssectceceracceecceciirn die esncte en acanesnnscbnecsascencduesesenctaeseanctendeeacce   Hazardous Substance Alert eae cases sate ss ice ne se ence eee ee eee eee ee  Sprayer COMPONe MS             cccccceccceeeeeeeeneceeeenesenecneeaeseneceneceaeeneeenecensenseonesenseeeseneseneseness    Getng SUA UC Ch cscs cote E E A  Starting Your Skid Sprayer for the First Time                 cccccccecceeseeeeeeeeeeeeseeeeeeseneseeseneseeeeeees  Shutting Down Your Skid Sprayer              ccccceecce sees ee eee nese neeeeeeeeeeen sean eeenseenssenesaaseaeeeanesenesness  Engaging   Disengaging the ReQulator              ccccccceseeeeeeeeeeeeeeeneseneseneseneseeeeeeessnesanesenesenesones    Troubleshooting Your Sprayer scciacg cece caeadecducee esi ctrsccnseeandecenenscecenestnetagsveneuceeceneeusvcepences     Warranty    5 year frame   5 year tank   1 year parts and labor  limited to manufacturer defects    1 year  pump  limited to manufacturer defects    3 year gas engine  limited to manufacturers defects      The warranty will not apply to
2.  3   4    To create pressure  screw the    T    handle clockwise to compress the spring until you  reach the desired PSI setting on the gauge    Lock in the pressure rating by tightening the nut on the    T    handle    To lower the pressure rating  unscrew the    T    handle counterclockwise    To prolong the life of the regulator   s internal components back the pressure off  before shutting down your sprayer     Troubleshooting Your Sprayer    Symptom  Pump does not prime    Loss of pressure    Pump will not turn    Possible Reason  Leak in suction line    Obstruction in suction line    Suction hose sucked to  bottom or side of tank  Rollers stuck in pump    Pump seals leaking air  Pump turning in wrong  direction   Clogged suction strainer    Kinked or blocked suction  hose  Air leak in inlet side plumbing    Relief valve setting too low or  weakened spring   Faulty gauge   Pump seals leak air   Nozzle orifices worm   Pump worn    Corrosion  rust   scale or  residue  Solid object lodged in pump    Correction   Check hose and fittings for  leaks and correct   Inspect hose for obstructions  such as debris or loose inner  liner and remove from the line  Cut a notch or    V    in end of  suction hose   Disassemble pump and  inspect rollers   Replace seals   Correct rotation of pump    Check strainer and clean  regularly   Inspect suction hose and  repair aS necessary   Check hose and connections  for leaks  Use pipe joint  sealant and retighten  connection   Check relief valv
3.  products that were improperly installed  misapplied  damaged   altered or incompatible with fluids or components  Kings Sprayers obligation under this  warranty is limited to the repair or replacement of the product  All returns will be tested per  factory criteria  Products found not defective  under the terms of this warranty  are subject to  charges paid by the returnee for testing and packing of    tested good    non warranty returns     No credit or labor allowances will be given for products returned as defective  Warranty  replacement will be shipped at Kings Sprayers discretion  Kings Sprayers reserves the right to  choose the method of transportation     Contact Kings Sprayers at 800 228 0905 to receive a Return Merchandise Authorization   RMA   before returning any products  The RMA number should be clearly marked on the  outside of the package  Kings Sprayers shall not be liable for freight damage incurred during  shipping  All products returned for warranty work should be sent shipping charges prepaid     General Safety Information   Roller pumps are intended for creating or booting dynamic pressure and depending on the type  of body  rotor and rollers used  will work with a variety of fluids  These pumps will work in a  variety of environments but they should never be used to pump liquids above 140  F  60  C  or  below 34  F  1  C   or when ambient air temperature is above 140  F  60  C   Any uses outside of  those specified in the pump manual are considered mis
4.  shoes and protective gloves in order to protect the feet  in the event the pump is dropped and protect the hands from chemicals or any sharp surfaces  on the pump     When spraying manually  chemical resistant facemasks and clothing should be worn to prevent  any chemicals from coming into contact with the skin or being inhaled     When spraying manually  always spray downwind of yourself as long as the sprayed chemical  will not drift into the vicinity of other people     When installing  adjusting or removing a roller pump  ensure that there are no objects which can  fall on the installer  and make certain that all machinery to which the pump is to be attached is  turned off     Never operate a roller pump outside while there is a chance of getting struck by lightning     Never leave wires or plumbing components where they can be a tripping hazard or become  entangled in a moving component     Roller pumps should not be used if the ambient light is below 200Iux     All maintenance should be done when machinery is stationary and has been isolated from its  energy sources  It is dangerous to perform maintenance while machinery is still connected to its  power source  Machinery should be isolated from its electrical  hydraulic  shaft driven or gas  engine power source     Be sure to release all pressure from the system before performing any sort of maintenance on a  roller pump     Hazardous Substance Alert    Any hazardous liquids should be disposed of in a manner that compl
5. e and correct  setting or replace spring  Replace gauge   Replace seals   Replace nozzles   Repair pump  See Repair  Instructions    Replace pump    Disassemble pump and  remove objects    
6. ies with local and national  regulations  Never dump fluids onto the ground     Always drain and flush pump before servicing or disassembling for any reason   Always drain and flush pump prior to returning unit for repair   Never store pumps containing hazardous chemicals     Before returning pump for service repair  drain out all liquids and flush unit with neutralizing  liquid  Then  drain the pump  Attach tag or include written notice certifying that this has been  done  Please note that it is illegal to ship or transport any hazardous chemicals without United  States Environmental Protection Agency Licensing     Sprayer Components       Ball valve to shut off   flow when cleaning  Strainer or servicing  sprayer       Inline strainer to  keep debris out of  system       Figure 1  Side View    Regulator     screw in out to  adjust pressure     in     increase     out    decrease   Nut to lock pressure setting    Unobstructed bypass line    Pressure gauge to calibrate  when spraying    On Off Ball valve for  agitation       Figure 2  Detailed View      Quick disconnect to  spray gun    50    high pressure hose       Figure 3  Back View       Figure 4  Side View    Getting Started    Starting Your Skid Sprayer for the First Time    NO        17     Ensure all unnecessary personnel are clear of the area    For initial testing  it is recommended to start with clean water instead of chemicals to  confirm the system and plumbing components are leak free    Ensure there is fluid i
7. n the tank and supply line  DO NOT run dry    Check line strainer for debris or clogs and remove if any found    Check all plumbing connections to ensure tightness    Ensure all valves and regulators are set to the desired setting and working properly   Ensure all hoses are positioned properly and undamaged    Then  follow these steps to starting the engine    First  set the ON OFF switch to the    ON    position    Set the throttle to SLOW    Make sure the gas is set to the ON position    For a cold start  set the choke to FULL    Pull start the engine    Release the choke    Raise the throttle to FULL    Pressure should be adjusting to approximately 150 psi  Notice a slight drop in  pressure when the agitator is turned ON and rise when it is turned to the OFF  position  The agitator mixes the tank to help evenly dispense chemicals    Adjust the spray gun to the proper setting and you are ready to spray     Shutting Down Your Skid Sprayer       _    Shut sprayer down using the outlined steps    Disengage the regulator   Refer to the Engaging Disengaging the Regulator section  below     Idle down the throttle to the    SLOW    position    If the pump will not be used for several hours flush your system to prolong the life of  the components     For a step by step video guide  visit the Sprayer Depot YouTube Channel to watch instructional  videos on a variety of topics  Tune in by visiting http   YouTube com SprayerDepot        Engaging   Disengaging the Regulator    1     2  
8. uses and are prohibited  Only use  approved chemicals in your pump  Contact Kings Sprayers with any questions regarding  specific acceptable uses     The following chemicals should never be put through any pump     e Gasoline  Petrol    e Kerosene Kerosine  Paraffin   e Diesel Fuel   e Ceramic Slurries   e Sewage   e Potable Water   e Abrasive Fluids    Roller pumps are designed to operate effectively within the specified speed  pressure and  environmental ranges  Going outside of these ranges will void the warranty and could cause  damage to property  serious injury or death     DO NOT run the pump faster than the maximum recommended speed   DO NOT run the pump higher than the maximum recommended pressure   DO NOT run pumps when the liquid  or ambient air  has exceed the maximum or minimum  temperature limit   DO NOT pump non approved liquids  See Below    DO NOT pump water or other liquids for human consumption   DO NOT operate any roller pump under the influence of drugs or alcohol   DO NOT run the pump dry   DO NOT pump abrasive fluids   DO NOT perform service or maintenance to the pump or attached components until the  pumping unit is below 109  F    Only authorized operators having the knowledge and skill necessary to safely use the pump  or  any equipment the pump is connected to  may run the pump     When running roller pumps  it is essential that operators use hearing protection as the sound  levels reach levels of 80 decibels     When handling pumps  wear steel toed
    