        Digital Dispense Controller
         Contents
1.   Pneumatic Tube PUN 6x1      Foot Switch Type No  97201     Power cord      Adapter 6 mm OD   4  NPT    Su     Operating manual      Terminating Plug     e As a result of technical development  the illustrations and descriptions in this instruction manual  can deviate in detail from the actual unit delivered     1 3 Field of Application  Intended Usage     The Digital Dispense Controller is used in conjunction with a Loctite Dispense Valve and a  Product Reservoir to make up a pressure   time dispensing system  Various dispense valves are  available depending on the process requirements and different size reservoirs  with or without  product level sensor  are also available depending on the product bottle size     Unit Features and Benefits  Features Benefits    Independent Controller     Allows choice of product reservoir       Avoids adhesive spills on controller       Provides for flexibility for future upgrades     Low Level Sensor Interface XS2     Provides a simple indicator input that is wired to a  female connector  which will accept most low level  sensors    Start Low Level Output XS1     Communicates low level condition to a remote device  such as plant PLC     Please observe the following    For Your Safety   For safe and successful operation of the unit  read these instructions completely  The  manufacturer cannot be held responsible for damage or injury of any kind because of misuse or  improper application or because of failure to observe safety instructions o
2.  2008    
3.  In time controlled mode  the dispensing time is  not changed     Buttons A V    Buttons for changing the dispensing time for a   dispensing sequence    When button A or V is pressed  the display   of the dispensing time  s  in the digital display   begins to blink  The dispensing time is adjustable   from 0 01 to 99 9 s    Buttons for switching from time controlled mode to   continuous mode    With the simultaneous pressing of the buttons for   more than 0 5 seconds  an operating mode change   takes place to the Continuous mode  In the display       con    appears  The lighting of the LED    CONT       indicates Continuous mode    During dispensing  the elapsed dispensing time is   indicated in the digital display beginning each time   with 0 00 s  The last dispensing time remains  displayed until the next start        Switching back to time controlled mode without  storage of the dispensing time by renewed  pressing of button A or Y  The LED  extinguishes  In the digital display  the dispensing  time is blinking        Switching back to time controlled mode with  storage of the dispensing time by pressing  button   The LED extinguishes  The indicated  dispensing time is stored     Digital Display  Three figure Display of the dispense time  s    LED    CONT       The lighting of the red LED    CONT    indicates  Continuous mode     3 1    3 1 1    3 1 2    3 2    3 3    Technical Data    Energy Requirements    Electrical  Power supply  Power consumption  Power protection    
4.  Keyboard  3 Power Switch 1 0  ON OFF   4 Power Supply Socket  5 Power Fuse  2 A semi time lag  glass type                A WARNING    Removing  bypassing or putting out of operation of  the safety devices can result in radiation damage to  persons and damage to the unit and is therefore  prohibited           6 Socket XS 1  Start  The footswitch is connected here  It is also the  output for the READY and EMPTY signals     7 Socket XS 2  Reservoir  The reservoir is connected here  It is the input for a  low level sensor  If no sensor is used  then connect  the supplied terminating plug here                 8 Pneumatic Supply P in  Air supply input for tube 6 mm OD  calibrated   Use supplied adapter to 14  NPT if required     9 Pneumatic Supply P out  This port supplies an unregulated air supply to a  remote reservoir  Use an external pressure regulator  if regulated air is required     10 Control Air Connection  Dispensing Valve    Dispensing valve open 1   Dispensing valve closed 0   Close port 0 for single actuated valve        2 Description                11  15     12  13  12 11  14  15    Button    Button for the storage of the new values set for the  dispensing time  s     When the indication of the dispensing time  s  in  the digital display blinks  the indicated dispensing  time is stored by pressing button and the display  stops blinking     Button    Button for filling the product feedline  In both  modes the product is dispensed as long as button is  pressed        
5. 881499  529516    The following spare parts can be ordered at your local industrial distributor     3 2 way solenoid valve  control valve for remote Festo Part Number  TESEEVOID ss ESE ETT 34307 MYH 3 M5 L LED  5 2 way solenoid valve  control valve for external Festo Part Number  dispensing Va N nee een tcu aM Qui eds 34309 MYH 5 2 MS5 L LED          8 Annex    8 2 Pin Assignment XS 1       CAUTION      Never connect external voltage on pin 1 or 9           Controller XS1 Footswitch    Internal relays   max  30 VDC  max  30 W   max  1A                       Switch closed  if controller is ready    Switch open    Switch closed if  reservoir is empty          Start with  Controller XS1 2 wire Proximity Switch    Internal relays   max  30 VDC  max  30 W   max  1A           Switch closed  if controller is ready    Switch open    Switch closed if  reservoir is empty          Start with  Controller XS1 3 wire Proximity Switch    Internal relays   max  30 VDC  max  30 W   max  1A           Switch closed  if controller is ready    Switch open    Switch closed if  reservoir is empty    output       13    8 Annex    8 3 Pin Assignment XS 2          CAUTION      Never connect external voltage on pin 1 or 9              Digital Level Sensor  2 wire    Controller XS2          E  X      Tank EMPTY            Tank EMPTY TankEMPTY   0  PNP  N O            E        0VDC GND        LES  24 VDC          Digital Level Sensor  Controller XS2 Aire                    r  a     EX     Tank EMPTY Blac
6. Internal control voltage    Pneumatics  Pneumatic supply    Quality   If the required quality is not  achieved  install a  LOCTITE  filter regulator    Power supply 90     260 V AC  47     63 Hz  Approx  25 W   Glass tube  fine wire fuse  2 A semi time lag  24 V DC    Min  5 bar  70 PSD  max  10 bar  145 PSI     Filtered 10 um  oil free  non condensing    Order Code no  see Section 8 1    Connections and Dimensions    Power connection  Dimensions    Pneumatic supply    Other Data  Weight   Operating Temperature  Storage Temperature    Continuous noise level    Cold appliance coupling IEC 320 acc  to VDE 0625  WxHxD  350 x 335 x 230 mm  13 8 x 13 2 x 9 1 inch     Internal Dia  4 mm  external Dia  6 mm 40 05   0 10  External Dia  4 in  is not suitable     Alternatively one fitting to 1 4  NPT is supplied     Approx  2 1 kg  4 6 Ibs     10   C to  40   C   50   F to  104   F    10   C to  60   C   14  F to  140   F      65 dB A     4 1    4 2    4 3       Installation    Environmental and Operating Conditions        Keep the pressure hose as short as possible        Keep product feed lines as short as possible  The shorter the feedline the smaller the specific  resistance and the lower the dispensing pressure can be  Avoid kinking        In any case  the pressure hose and product feedline should not be longer than 2 m        Do not use inflexible hoses and feed lines  so that unnecessary loads on the fittings will be  avoided        Keep all fittings tight        No direct sunli
7. LOGTITE        Operating Manual  Bedienungsanleitung    Digital Dispense Controller    97101       1 1  1 2  1 3  1 4    2 1  2 2    3 1  3 1 1  3 1 2   3 2   3 3    4    4 2  4 3    5    5 2  5 2 1  5 2 2  5 3  5 4    8 1  8 2  8 3  8 4  8 5    Contents    Please observe the following                         sssssseseeeeeeneeennnne nennen 3  Emphasized SCH OMS sax cece eure 3  Items Supplied  ee                      e     3  Field of Application  Intended  Usage   iszsctisonsscuccessaistanecessansnausceaissasbedeseuesevnbanceussavenuness 3  POT YOU ADC LY esn PD LE 4  Ibo sii RET        M 5  Theory ot Operations nee nenn 5  Int  rtace and ConnecHols ee een 6  Techmcal Data  aeo o aes ep SR dade en en 8  Energy RequiteHietifsx naar ie 8  Electricals a LU m M uM M eens Sie E 8  Phneumatles dato eco uM REM le 8  Connections and Dimensions    8  cg Pri ERT EA E 8  Installation e                                                   9  Environmental and Operating Conditions                        essere 9  S Pace ds CQUITCIICIUS audeas ipea oot o RUE RE MO on ea ka 9  Comins Cline the UN idis rct on o Ead o m od i a diat Rd ht a dd dea ax 9  Dispensa omo Menon nae tU uM tutu beet E uM qui VIAE 10  Settine anto ODE AOT sapra qe ta Eee et er nat UHR uetus du aa ERE oM udi c Ga de dd 10  Adjusting the dispensed Quantity   22 3 vedo a Ent OH S FERRE Rea IRR din qud 10  Time controlled Modes en an a ORE nop ido a 10  COH mous  MOS desc essetis ee Des EAM Et LM m E 10  Shutdown for Longer 
8. Periods of NON USC             ccccssscccessesnseeceeesesneeeeesseseeeceseesseeeeees 11  Returning to Operation after Longer Periods of Non use                    sess 11  Care  and Maintenance     use dens EISERES iei 11  Troubleshooting a    radio a RO d E DEEP eiii o detti ees 11  PO d C TE 12  Spare Pl eee PCR ME MOINS ee I RD AMA UA D MA IE 12  PainXsSSt Prime Hb  RS LEIDER 13  Pim ASSOLE 9 2  asien estnischen 14  Pneumatic Diara M o en dates a a ea a ea aie aaia saaat 15    De  claration ol Conloniyin anne ae ae 15    1 Please observe the following    1 1   Emphasized Sections       Warning   A Refers to safety regulations and requires safety measures that protect the operator or other persons  from injury or danger to life           Caution   Emphasizes what must be done or avoided so that the unit or other property  is not damaged           D Notice    Gives recommendations for better handling or adjustment of the unit during operation as well as  for service activities     The numbers printed in bold in the text refer to the corresponding position numbers in the  illustration on page 6 7        e The point emphasizes an instruction step   Instruction steps in the illustrations are  indicated with arrows    When several instruction steps are indicated    in an illustration  the shading of the arrow P P e ZA    has the following meaning     Black arrow   1    step  Grey arrow   2    step  White arrow   3  step    1 2 Items Supplied        Digital Dispense Controller   
9. a remote reservoir and the pneumatic opening of a dispense valve according to the  selected dispensing time   The start signal for dispensing is provided by an external foot switch   An external sensor activates a low level indicator  The low level condition can also be  communicated to a remote device   The amount of product dispensed is controlled by three main factors       Amount of pressure in the reservoir      Length of time the dispensing valve remains open      Dispensing needle size    Additional Features    Two additional features are available     EMPTY     If the reservoir is empty  the contact of the level sensor opens  A beeping tone indicates the  message and the symbol for an empty reservoir    U    is displayed     READY     If the dispensing cycle is finished and the reservoir is not empty  this contact closes    Both signals are available as dry contacts at the XS 1 start interface for optional connection to a  higher ranking controller or a warning light    The start of a dispensing cycle is not locked when EMPTY is indicated        Caution   Pay attention if cyanoacrylate is dispensed     Air in the feedline results in curing of the product        When the user quits the EMPTY message and the beeping tone with the button ENTER the signal  at the interface XS 1 is quit  too    The READY signal will only be indicated when the reservoir is refilled and the sensor is  activated     2 Description    2 2 Interface and Connections       1 Timer Display  3 2 1 2
10. ack to time controlled mode without storage of the dispensing time by renewed  pressing of button Aor Ww   The LED extinguishes  In the digital display  the dispensing  time is blinking        Switching back to time controlled mode with storage of the dispensing time by  pressing button   The LED extinguishes  The indicated dispensing time is stored     5 Dispensing    5 3 Shutdown for Longer Periods of Non use    e Disconnect the pneumatic supply from the controller     5 4 X Returning to Operation after Longer Periods of Non use    e Reconnect the pneumatic supply to the controller     e Check the installation according to Chapter 4   e Return to operation according to Section 5 1     6 Care and Maintenance    The unit requires no special care and maintenance        CAUTION        Observe the operating manuals of the dispense valve and remote reservoir used        7 Troubleshooting       Type of Malfunction Possible Causes    Corrections       The digital display does not   No power voltage present     light       Power fuse 5 is defective       Power cord is defective       Control unit is defective         Plug on the socket XS 1  Start 9 is  loose     No start signal         Footswitch defective        Reservoir is empty   low level  indicator on        Continuous mode is activated   LED is on      Timer is not operating        Low level indicator is on       Product package is empty         Powers switch 3 in position 0  OFF      e Check the power voltage    e Switch po
11. ght  no UV light        No condensing humidity        No splash water     opace Requirements                Connecting the Unit   The numbers printed in bold in the text refer to the corresponding position numbers in the  illustration on page 6 7    e Use only the cable and hose sets supplied    e Connect power cord to power supply socket 4     e Connect air pressure supply to pneumatic connection P in  8   If necessary  use fitting to 14  NPT supplied with this unit   e Connect footswitch to socket XS 1  6   e Connect dispensing valve to pneumatic connection 10   Dispensing valve open 1   Dispensing valve closed 0   Close port 0 for single actuated valve   e Connect remote reservoir to pneumatic connection P out  9   Insert an external pressure regulator  if regulated air is required   e Optional  Connect low level sensor to socket XS 2  7   If no level sensor is used  then connect supplied terminating plug here     10    5 1    Dispensing    Setting into Operation       CAUTION   Observe the operating manuals of the dispense valve and remote reservoir used        5 2    5 2 1    9 2 2    Switch the power switch 3 to position 1  ON    Adjusting the dispensed Quantity    Time Controlled Mode    This mode of operation is used for spot shaped wetting or drop dispensing     e With buttons A or V set the dispensing time to 0 50 s   The indication of the dispensing time in the digital display  begins blinking              e With the pressure regulator of the remote reservoir set t
12. he        CONT  dispensing pressure to 0 5 bar  approx  7 PSI   A  If the dispensed quantity is too small         gt     e Increase the dispensing pressure  After this check the    dispensed quantity  Repeat this sequence until the desired  dispensed quantity is roughly achieved           When the desired dispensed quantity is roughly achieved   e Set the exact dispensed quantity by changing the dispensing time with button A or V  f  e Press the footswitch to check the dispensed quantity     Storing of the dispensed quantity setting for subsequent dispensing   e Press button      The indication of the dispensing time in the digital display stops blinking     If the desired dispensed quantity is not achieved   e With a larger  or smaller  dispensing needle  repeat the steps of this section     Continuous Mode    This mode of operation is used for the application of beads        e With the pressure regulator of the remote reservoir set the  dispensing pressure to 0 5 bar  approx  7 PSI      e Press the buttons A and Z simultaneously  The lighting x  of the LED    CONT     indicates Continuous mode  The  display of the dispensing time in the digital display is set CONT  to con  A z  e Press the button  or the foot switch  to check if the  product is ejected quickly enough from the dispensing     gt    needle           When the dispensed quantity is achieved too slowly    e Increase the dispensing pressure or repeat this sequence with a larger dispensing needle        Switching b
13. k       Tank EMPTY TankEMPTY      PNP  N O          amp 7 0VDC GND    EE    24 VDC          Terminating Plug    Controller XS2 if no Sensor used    ae pem      EX  TankEMPTY 2  Se zn  eer 4    ovbc GND      zo exc  pc   GEI c  x m       xa  24VDC 3          Type No      8    8 4    8 5    8954672    Annex    Pneumatic Diagram          MYH 5 2 M5 L LED        P out C       MYH 3 M5 L LED         P in 6 8 bar  87 116 psi        Declaration of Conformity       The Manufacturer Henkel KGaA   according to the EC regulations Standort M  nchen  Arabellastra  e 17  D 81925 M  nchen    declares that the unit designated in the following is  as a result of its design and construction  in accordance  with the European regulations  harmonized standards and national standards listed below     Designation of the unit Digital Dispense Controller 97101  Order code no  961819  Applicable EC Regulations EC Directive for Low Voltage 73 23 EEC    EC Directive for Electro Magnetic Compatibility  89 336 EEC  including changes 91 263 EC  92 31   93 68 EC      EN 60204 1  1997  EN 61 000 6 3 2001    C and        Applicable harmonized standards       Henkel KGaA  Standort sur  AX  Arabellastra  e 17 IN  Due MAHUHICHMEET Se eee 81925 M  nchen d  v  n Ameln     i    This declaration is not valid if there are any changes not app roved by Henkel        Edition  Nov  2007    15       Henkel AG  amp  Co  KGaA  Standort M  nchen  Gutenbergstra  e 3  D 85748 Garching b  M  nchen       Henkel AG  amp  Co  KGaA
14. r warnings    Be sure to retain this manual for future reference    Request the technical data sheet and the safety data sheet for the LOCTITE   product used at  www  loctite com for US and Canada version of data sheets        FOLLOW UNCONDITIONALLY THE INSTRUCTIONS OF THESE DATA SHEETS        WARNING     It is the responsibility of the user to ensure that all devices being driven by the Digital Dispense  Controller are set up in a safe manner     The manufacturer is in no way responsible for injuries or damage to persons or property resulting  from devices being driven by the Digital Dispense Controller     For safe and successful operation of the unit  read these instructions completely  If the instructions  are not observed  the manufacturer can assume no responsibility     Removing  bypassing or putting out of operation of the safety devices can result in radiation  damage to persons and damage to the unit and is therefore prohibited     When working with pressurized air  wear protective glasses     Damage to the power cord or the housing can result in contact with live electrical parts  Check the  power cord and the unit before each use  If the power cord or the unit is damaged  do not operate   Replace a damaged power cord with a new one     The unit may be opened and repaired only by authorized service personal        2 Description    2 1   Theory of Operation  The Digital Dispense Controller is connected to an external pneumatic supply  It controls the air  supply to 
15. wer switch to position 1  ON    e Check replace fuse    e Replace power cord    e Henkel Service     e Switch the power switch to the position 0   OFF   Tighten the screws of the plug   Switch the power switch to the position 1   ON     e Replace the Footswitch    e Refill reservoir        e Press the buttons  A and V  simultaneously to switch back to time  controlled mode     e Adjust low level sensor   e Refill reservoir        No air pressure at reservoir      No power voltage present         Powers switch 3 in position 0  OFF          No incoming air supply     e Check the power voltage   e Switch power switch to position 1  ON    e Check air supply           No air supply to dispense     No power voltage present     valve     Powers switch 3 in position 0  OFF             No incoming air supply     e Check the power voltage   e Switch power switch to position 1  ON    e Check air supply        11    12    8 Annex    8 1   Spare Parts and Accessories    Item Description Type No     Filter RE OAL GR een 985397  Requires fitting 1 4 inch Male NPT x 1 8 inch Male NPT     989071     TASES WAI a ran 97201    Power Cord      cold appliance coupling IEC 320 acc  To VDE 0625  male   connector according to the national regulations such as   DIN  VDE  IEC  SEV  UL  CSA  SEMKO  IEC B S     IEC 3 pin US    Power Supply Est 8950490  ERBE AE 8950891  Power Fuse  2 A   250 V semi time lag  glass type  5x20       mm  according IEC 60127 2 V     Order Code No   478603   739975   88653    
    