Home
DL205 Communications Modules
Contents
1. 422 signal levels DirecfNET Master Slave K sequence or Modbus RTU Slave protocol Baud rate selectable from 300 sa to 38 4 Kbaud Odd or No parity DirecfNET HEX or ASCII mode Recommended Cable Belden 9729 or equivalent for RS 422 Field Wiring Connector 25 pin D shell connector Internal Power Consumption 300 mA maximum at 5 VDC supplied by base power supply Operating Environment 0 C to 60 C 32 F to 140 F 5 to 95 humidity non condensing Manufacturer DCM as additional serial port DCM as master Koyo Electronics R9232 to RS422 Converter D3 340 slave Modbus RTU interface The DCM can be used as a slave station interface to connect your DL205 system to a Modbus network using the Modbus RTU protocol The host system must be capable of issuing the Modbus commands to read or write the appropriate data Remember that the bottom port on the D2 250 1 and D2 260 CPUs can act as a Modbus master D2 DCM slave DL 405 CPU bottom port 1 800 633 0405 Serial Module for WinPLC and EBC Systems Serial Communications Module for WinPLCs amp EBCs Serial I O module for WinPLCs Add serial ports to your WinPLC system by simply plugging the H2 SERIO modules into the DL205 I O base This serial module
2. 0 ECOMIO0 Slot status Workspace hisg Buffer 65 WORDS ECOM100 Read Network IBox MA ECOM100 Ra Network Read ECRX ECOM100 Workspace Slave ID From Slave Element Src Number Of Bytes To Master Element Dest Success Error PPO FSP ol oj E 2 Co a el 4 T cc ECOM100 Send EMail IBox ECOM1TOO Send EMail ECEMAIL ECOM100 Workspace Success Error Error Code To steven Subject Machine Offline Body Machine 5010 8 went offline at _time 24 on _date us MASDGLS TEF Saar wert MOOSE TCE Giant amp MOGBUS TCF Ellan Sorar HH ECO od marry a i l NetEdit3 software NetEdit3 Software ships free with the ECOM User Manual Use NetEdit3 to configure the ECOM modules for your network Flexible addressing allows you to use your choice of protocols and identi fying methods Assign each module a number or a name or both You don t have to use an IP address but you can if it s necessary for your network NetEdit3 uses two protocols tor PC to PLC commu nications IPX and TCP IP The NetEdit3 screen displays all identitiers and trou bleshooting information for each module on the network You can use NetEdit3 to adjust parameters for PLC to PLC communications by clicking on Advanced Settings The network identifiers can also be changed from __ DirectSOFT Programming Software Choose your slot The ECOM modules plug into a
3. Serial Data Communications Module Specifications Data ins Communications Module The D2 DCM Data Communications Module is used primarily for three reasons Extra communications port to connect a PC operator interface etc e Network interface to DirectNET e Network interface to a Modbus hetwork using the RTU protocol Extra communications port If additional communication ports are needed they can easily be added by installing DCM modules This allows addi tional connections of devices such as operator interfaces PCs etc Since the DCM does not require any programming you can set the DCM communication parameters connect the cables and start transferring data Make sure the device has a DL205 compatible driver DirectNET network interface The DCM can be used as a network inter face for applications requiring data to be shared between PLCs or between PLCs and an intelligent device such as a host PC The DCM connects easily to DirectNET This network allows you to upload or download virtually any type of system data including Timer Counter data I O information and V memory information from any DirectLOGIC or compatible PLC The DCM allows the DL205 to function as a network master or network slave 4 56 PLC Products Module Type Intelligent Modules per CPU 7 maximum slot 1 or higher CPUs Supported D2 240 firmware V1 8 or later D2 250 1 and D2 260 Communications RS 232
4. blems Use repeaters to extend distances and expand the number of nodes Our HA TADP 10 100Base T PC network adapter card and E SWO5U Ethernet switch is compatible with the ECOM modules See the Communications Products section for information on these items ECOM starter kit The H2 ECOM START gives you every thing you need to make your first Ethernet network simple to build It contains an H2 ECOM module and instruction manual a network adapter card PCI tor your PC a crossover cable and a Software Product Showcase Demo CD The CD contains demo versions of our software products that support the ECOM Modules See the Software Products section for information on the available sottware packages Message is sent out of port only connect ed to device Message in See the Communications section for details on the E SW05U Ethernet Switch Specifications H2 ECOM H2 ECOM100 Box communications Instructions Over 25 Communications IBox instruc tions are available when using the H2 ECOM100 with a DL250 1 or DL260 PLC and DirectSOFT5 programming software These easy to use instructions allow you to Enable disable module DHCP Read write module IP Gateway and Subnet Mask addresses Read write module ID Name and Description e Send E mail messages Read Write PLC memory to networked Hx ECOM 100 modules Read Write PLC memory to networked Hx ECOM F modules See the following page for example Communi
5. cations IBox instructions The H2 ECOM100 supports the Industry Standard Modbus TCP Client Server Protocol H2 ECOM100 H2 ECOM F 10Base FL Ethernet 10 Mbps max 2 000 meters 6 560 ft ST style fiber optic TCP IP IPX 640 mA 5 VDC Communications 10Base T Ethernet 10 100Base T Ethernet Data Transfer Rate 10 Mbps max 100 Mbps max Link Distance 100 meters 328 ft 100 meters 328 ft Ethernet Port RJ45 RJ45 TCP IP IPX Modbus TCP Ethernet Protocols TCP IP IPX DHCP HTML configuration 450 mA 5VDC 300 mA 5 VDC Host Automation Products L L C cables hubs and repeaters Or use our KEPDirect O Server to link to your favorite HMI SCADA data historian MES or ERP sottware to DirectLOGIC PLCs Our LookoutDirect HMI and our DataWorx data collection software include ECOM drivers DirectSOFT Programming Software Power Consumption Manufacturer 4 58 E PLC Products 1 800 633 0405 Ethernet Communications Modules Modbus TCP communications architecture Modbus TCP support The H2 ECOM100 supports the industry standard Modbus TCP Client Server protocol in addition to the standard IP and IPX protocols This allows the DL205 PLC with an H2 ECOM100 module to serve as a client master or as a server slave on a Modbus TCP Ethernet network The H2 ECOM100 can actively issue Modbus commands to other nodes or devices on the Modbus TCP network or simply resoond to connected Modbu
6. is used exclusively with the WinPLC The WinPLC communicates with the H2 SERIO module across the DL205 backplane Up to ten serial ports on aWinPLC system The WinPLC has one built in serial port You can add as many as nine additional serial ports for Think amp Do Studio or Think amp Do Live applications requiring multiple serial devices such as barcode scanners Connect to just about any serial device that communicates ASCII protocol The H2 SERIO can also serve as a Modbus RTU slave Processing large amounts of serial data with a WinPLC While the H2 SERIO module will support virtually any serial device processing large amounts of serial data will increase the system response time This is impor tant to consider when using multiple H2 SERIO modules especially in a WinPLC local base with an H2 ERM or H2 CTRIO H2 SERIO Specifications Module Type Intelligent module for use with H2 WPLC or PC EBC system of Serial Ports per Module 3 of modules supported per WinPLC 3 of modules supported per EBC node 3 Protocols Supported Serial ASCII and Modbus RTU slave Connector RJ12 jack Power Consumption 210 mA 5 VDC Operating Environment 0 to 60 C 32 F to 140 F 5 to 95 RH non condensing Manufacturer Separate communications parameters for each port Use Think amp Do software packages to set baud rate parity data bits and stop bits fo
7. ny I O slot excluding slot O of any local DL205 I O base The module maintains identifi cation data descriptive information and communication parameters tor PLC to PLC communications in tlash memory Disconnect power before installing or removing any PLC module G ae a a a 205 CPU A A p g ey SlotO Slot 1 S lot 2 Slot3 Slot 4 o No mimitiminitiminm Note Use D2 240 D2 250 D2 250 1 or D2 260 CPUs with the ECOM modules The D2 230 CPU and D2 CM bases do not support the ECOM modules PLC Products 4 59 eee 4 vyv PLC Overview DL05 06 PLC DL105 PLC DL205 PLC DL305 PLC DL405 PLC Field I O Software C more HMIs Other HMI AC Drives Motors Steppers Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pushbuttons Lights Process Relays Timers Comm TB s amp Wiring Power Circuit Protection Enclosures Appendix Part Index
8. ontrols Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pushbuttons Lights Process Relays Timers Comm TB s amp Wiring Power Circuit Protection Enclosures Appendix Part Index Ethernet Communications Modules Ethernet Communications Module Overview Ethernet Communications Modules offer features such as e High speed peer to peer networking of PLCS Fast updates with DirectSOFT Programming Software e High performance access for Human Machine Interface HMI ERP MES or other Windows based software e Industry standard Modbus TCP Client Server Protocol H2 ECOM 100 Free SDK for custom drivers Easy setup The Ethernet Communication ECOM Modules represent a price breakthrough for high speed peer to peer networking of PLCs No longer are you forced to desig nate a single PLC to be the network master Any PLC can initiate communica tions with any other PLC Link your PLCs with PCs using industry standard Modbus TCP protocol connected through standard can be used to monitor or update the program in any DirectLOGIC PLC on the network Simple connections Use Category 5 UTP cables or 62 5 125 ST style fiber optic cables depending on the requirements of your application Inexpensive UTP cables can be run up to 100 meters between nodes and fiber optic cables can be run up to 2 000 meters Fiber optic cables virtually elimi nate electrical noise pro
9. r each serial port Choose trom 300 baud to 57 6K baud communication speeds Think amp Do Studio or Think amp Do Live allows each port to be designated as a Modbus slave or a generic serial device Each port on the H2 SERIO module is capable of full hardware hand shaking Easy serial communications All Think amp Do PC control software prod ucts include advanced string and array functions that make transmitting receiving and manipulating serial data a snap Host Automation Products L L C Using H2 SERIO in a PC based control EBC system Think amp Do Studio version 6 5 supports the use of up to three H2 SERIO modules per EBC node in a PC based control system The master must be a PC running Studio 6 5 or later This does not apply to a WinPLC system with an ERM module used for remote I O The Think amp Do features listed on this page for the WinPLC receiving and manipulating data also apply to a PC running the Think amp Do software Pin Assignments for H2 SERIO ports CTS Clear to Send RTS Request to Send aS a AR Q DH www automationdirect com dl205 OV Power Connection GND RXD Receive Data RS 232 TXD Transmit Data RS 232 OV Signal Ground GND RJ12 6P6C Female Modular Connector PLC Products 4 57 PLC Overview DL05 06 PLC DL105 PLC DL205 PLC Field I O Software C more HMIs Other HMI AC Drives Motors Steppers Servos Motor C
10. s TCP clients PLC to PLC communications PLC to PLC or PLC to a Modbus TCP device communications can be accom plished using standard Read trom Network RX and Write to Network WX instruc tions DL240 250 1 260 all H2 series ECOMs and all DirectSOFT versions It you re using our new DirectSOFTS5 programming software a DL250 1 or DL260 PLC and an H2 ECOMI1OO you can use fill in the blank IBox instructions to simplify your communications program ming The H2 ECOMI100 supports the ECOM100 Configuration Box for use with the ECRX and ECWX Box instructions to read write to other ECOM 100 s All H2 series ECOM modules support the NETCFG Configuration IBox for use with the NETRX and NETWX IBox instructions to read write to other ECOM modules remember DL250 1 260 and DSOFTS5 required The Communications IBox instructions execute with built in inter locking to greatly simplify communications programming H2 ECOM100 has e mail capability The H2 ECOM100 Send EMail ECEMAIL Box instruction allows the module to behave as an e mail client and send an SMIP request to your SMTP Server to send a specitied e mail message to the e mail addresses in the in Box s To field The Body field allows you to embed real time data in your e mail message The DL50 1 260 CPU and DirectSOFT5 are required to use the Box instructions www automationdirect com dl205 H7 ECOm100 ECOM100 Configuration IBox ECOMAOO Contig ECOM10
Download Pdf Manuals
Related Search
Related Contents
MHTL-MAGNT8 Troffer User Manual VITEK 2 Systems Online Software User Manual Wöhler A 400 e A 400PRO Wöhler A 400iHC OPC Gateway Server Benutzerhandbuch (deutsch) ℼⅲ⅄⅚ ে Toshiba 26EL833 26" HD-Ready 3D compatibility Black LED TV Manual de la columna abatible alta Istruzioni USER MANUAL 取扱説明書の種類と使い方 Copyright © All rights reserved.