1. Hybridization Incubator DHI 37 g USER S MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3 Hagavish st Israel 58817 Tel 972 3 5595252 Fax 972 3 5594529 mrc mrclab com MRC 8 15 Contents LOCK Correct temperature tolerance SHIF auto calculating Manual controlled 3 Speed control 3 1 Shaking setting e Error message and trouble shooting for temperature controller e MAINTENANCE amp CLEANING e WARRANTY CARD SPECIFICATIONS DESCRIPTION RANGE Ambient 5 C to 80 C ACCURACY 0 1 C CONTROL PID Controller DISPLAY LED Digital Display SPEED ROTATION CAPACITY SPEED SHAKER TYPE CAPACITY 6 to50 r p m 8 GLASS 10 to 100 r p m ROTATION Orbital Carry 6kgs MATERIAL INSIDE Stainless steel SUS 304 OUTSIDE Powder painting PLATFORM 310x210mm 350x250x425mm DIMENSIONS OVERALL 440x375x660 mm ann 110 V 60 Hz 220V 60Hz PANELO KEY DESCRIPTION dj 0d 33dS 1 Main power switch turn on off main power Shaking speed switch turn on to start shaking 2 Temp Control display setting and actual temperature 3 Speed control display setting and actual speed 4 Rotisserie control display setting and actual speed OPERATIONS DESCRIPTION After making sure voltage please plug in 110V 220V socket 1 Power POWER on setting temperature SPEED on setting speed of shaking and rotating 2 Temperature control 1 Key for
2. specified extended line to avoid overload and to ensure operating smoothly and service life Please make sure voltage before use we are not responsible for any damage caused by insufficient voltage Please install it on smooth floor to avoid shaking and noise Please switch off main power and open door for 2 3 days to dry inside and parts and to extend its service life WARRANTY CARD gt RN j Warranty period Company Stamp Invalid without company stamp Condition of warranty 1 One year warranty from the date of purchase 2 In case damage is under normal condition of use within warranty we will repair at no charge 3 In case any manufacturing defect is found it will be replaced with a new one free of charge 4 Damage caused by card lost human negligence misuse or acts of God during warranty we will repair at a reasonable charge 5 This warranty card is invalid without company stamp and will not be re issued in case it is lost 15
3. Setting selecting to select parameter for viewing or adjusting 2 Key for decreasing gradually to decrease parameter 3 Key for increasing gradually to increase parameter 4 return confirm key a have monitor returned to PV value display present measuring value and setting value b clear latch alarm when alarm condition has been eliminated c exit manual control mode auto calculating mode and calibrating mode d clear error message or auto calculating error message e restart constant temperature timer f Display output percentage on failure mode with manual control Display actual temperature parameter and error message Display setting value parameter and control output value N auto calculating LED See the page 9 00 8 Manual controlled LED See the page 9 9 Over Low LED no this function 10 Overheat LED See the page 9 11 Heating LED See the page 10 12 centigrade LED LED on means temperature is centigrade 13 Fahrenheit LED LED on means temperature is Fahrenheit 2 1 Setting temperature 1 The temperature setting is lower than room temperature that you should turn on the Cooling switch 2 PV displays the actual temperature in chamber 3 SV displays the setting temperature Press A to increase temperature gradually Press to decrease temperature gradually 4 Setting temperature upon what you need 2 2 Setting parameter 1 Press select
4. amber bath inside actual temperature is higher than setting temperature PT platinum breakdown Thermometer output signal nil Heater disconnection Bad heater circuit Bad control circuit High temperature protection setting locking Water level of floating ball is too low water bath Temperature is out of control b Heater circuit is out of control P I D value is not correct S S R breakdown Temperature is unstable P T D value is not set or not correct Temperature setting is too close to room temperature circulating fan or motor cannot work PT platinum bad connection Air circulation inside is blocked Check power supply system Plug in firmly or replace the socket Check power supply and stop using temporarily Check power voltage and reset Replace switch Replace power cord Waiting for temperature dropping or cooling Replace Ask for repair Ask for repair Ask for repair Ask for repair Reset Water supply Ask for repair b Ask for repair Re calculating automatically Ask for repair Suspend for30 minute Re calculating AT automatically Add cooling system or dropping ambient temperature Ask for repair Ask for repair Improve articles placement MAINTENANCE CLEANING 1 Please follow specification to use the specified socket Do not use old or loosened socket and not use same socket with other machines Instead of general extended line please use single circuit and
5. ed then release pressing selecting key about 5 seconds to enter manual control mode 1 means OP1 output percentage means OP2 output percentage e OverHeat LED LED on means overheat protection is on press select key PV displays SP2 SV displays default overheat temperature protected value 5 C For example the setting temperature is 100 C and default overheat protected value is 5 C when rising to 105 C sO LED will be and stop heating e Heating LED LED on means heating now If the machine includes timer chamber temperature start dropping after time out at this time there is no heating though heating LED is on 3 Speed control of shaking 1 Power Suspend on Press P S for 5 seconds to power on off 2 Decrease key Press it to decrease parameter value 3 Increase key Press it to increase parameter value Press P S to suspend working Es Set timing shift key Press it to set timing Press it to execute shift key at setting RPM mode 5 Set RPM revolutions per minute shift key Press it to set RPM Execute shift key function at set timing mode 6 Display actual RPM revolutions per minute 7 Display setting RPM or TIME LII Hour indicator Led 9 Minute indicator Led 10 08 Second indicator Led 3 1 Shaking setting R P M range 10 100 Speed setting 1 OV A UU N Set RPM At Suspend mode press indicator Led off Press Sffirst SV fla
6. key for 5 seconds to display then release select key and re press select key to modify temperature parameter 2 SHIF setting is completed and then press R to make sure xN ote When LOCK NONE and no parameter is locked user can change it freely 1 LOCK SET all functions parameters are locked 2 LOCK USER all parameters are locked except S P 3 LOCK ALL all parameters are locked to prevent from being changed e Modify inaccurate temperature value SHIF In normal condition set SHIF to 0 sometimes PV value is inaccurate because of detecting from different point at this time please modify it by SHIF value When SHIF 0 then PV 100 C If SHIF setting 20 00 then PV 120 C If SHIF setting 10 0 then PV 90 C For Example PV actual temperature is 100 C and SV temperature setting is also100 C If Thermometer appears 120 or 90 C Then set SHIF 20 or 10 Auto calculating LED Instrument has been set the best PID value we suggest executing auto calculating when temperature is unstable Enter auto calculating press selecting key until is displayed then release selecting key Press selecting key again for 5 seconds to enter auto calculating all parameters setting must be correct before executing auto calculating and must be LOCK NONE e Manual controlled LED enter manual control mode for testing or system failure Enter manual control mode Keep pressing selecting key until is display
7. sh Press D to shift key Press Shift up key to increase gradually Press Shift down key to decrease gradually Complete setting press make sure 7 Press P S power on indicator Led on e imer setting 1 Set timing At suspend mode press S E indicator Led off 2 Press first to set timing 3 Then press A or V to select to set 999 hours eM to set 999 minutes to set 999 seconds Press SV flash Press S to shift key Press A to increase gradually Press V to decrease gradually After setting press D to make sure then go to RPM mode automatically user can set or make sure RPM Oo A 9 After setting press D to return to set timing mode indicator Led on then set timing is completed 10 Press S E power on indicator Led on 11 After power on press to display RPM or display setting time 12 After power on press D to display time time count backwards 4 Speed control of rotating R P M range 6 40 Same as 3 TROUBLESHOOTING SITUATION CAUSE TROUBLESHOOTING 1 LED is off when power on 2 After temperature setting Heating LED OUT1 is off 3 Heating LED is on but temperature can not rise 4 Temperature keep rising and out of control 5 temperature tolerance is large 13 NO power input Power plug is loose Abnormal voltage input Fuse blowout Power cord disconnection or bad connection Ch