PSTN Wireless Home Alarm System User Manual as PDF
Contents
1. Enable disable remote control anti decode If there is a risk of someone using an automated decoding system to disarm your system the remote control disarm buttons can be disabled to increase security Once this feature is enabled the alarm panel will ignore DISARM signals from all remote controls Only the keypad in the control panel button can disarm the system The AWAY HOME and PANIC buttons of the remote controls will still operate This feature may also be useful if a remote control has been lost Just remember the only way to disarm will be at the alarm panel Command while in programming mode Enable 18 1 This setting disables the remote control DISARM button Disable 18 0 This setting allows normal operation the remote control DISARM button 12 Enable Disable telephone line connection check When enabled the alarm panel will beep three times every 10 seconds if the phone line is cut or shorted When the alarm is armed in AWAY mode the siren will also sound if the phone line is cut or shorted In HOME mode only the panel will beep Command while in programming mode Enable 22 1 Disable 22 0 Alarm panel answer number of rings You can setup the number of rings before the control panel answers an incoming call Command while in programming mode 12 XX XX shows number of rings from 00 12 When set to 00 an incoming call will not be answered by the alarm panel Siren alert
2. to avoid registering it again Remote controls You can press any key on the remote to register it The alarm panel will also beep Gas and smoke detectors There is usually a test switch which you can press to register it with control panel Glass break sensors You can put it on a desk and then shake the desk it will send a signal to control panel The control panel will respond with a beep which indicates successful registration While in the programming state the below commands will allow access to each zone The alarm will beep two times and the ALARM LED will start flashing indicating that you have entered the registering mode The LED of the zone you are registering sensors in will also be illuminated Momentarily trigger each sensors or detectors you are going to register for the zone it will be used in If you register a sensor in two zones the panel will only register it for the last zone in which it was registered Enter 7 to gain access sensor registration The panel will default to Zone 1 Zone 1 trigger sensors for this zone Enter 01 if later you need to return to Zone 1 for additional sensors Zone 2 Enter 02 and trigger sensors for this zone Zone 3 Enter 03 and trigger sensors for this zone Zone 4 Enter 04 and trigger sensors for this zone Zone 5 Enter 06 and trigger sensors for this zone Zone 6 Enter 05 and trigger sensors for this zone Note When registering the remote controls you may wish
3. the alarm is tripped again it indicates additional activity in the defense area covered by the alarm panel If you do not input the alarm system will continue to dial out all alarm phone numbers circularly a total of 3 times each 17 IX Remote operation via telephone Call the telephone number of the line connected to the alarm control panel After the alarm panel answers the call input the password If the password is correct the system will beep two times If wrong it will beep for four times The system will hang off automatically if passwords entered are wrong for 3 times or no further commands are entered within 20 seconds If the password is accepted you can control the panel with following commands Press 1 to arm the alarm panel in the AWAY mode It will immediately arm no 30 second delay Press 2 to disarm the alarm panel Press to enter into a 30 second listening mode Press to exit and disconnect the call Note Be careful not to enter other numbers than the above after entering the password successfully When you enter the password above you are also entering the programming section of the alarm operation Pressing other keys can alter your alarm s programmed settings 18 X Use of remote controls a AWAY button press it to arm the system The siren will have a short chirp if siren notification is enabled b HOME button press it to arm the exterior sensors when you
4. time You can setup the siren to sound for 00 to 30 minutes When set to 00 the siren will not sound Command while in programming mode 29 XX XX is 00 30 minutes Siren notification for arming disarming a To provide a chirp of the siren during arming and disarming Command while in programming mode 8 b To disable the chirp of the siren during alarming and disarming Command while in programming mode 8 13 Reset of all programmed information You can delete all registered information including the password and ALL sensor programming in order to return the original status before leaving the factory You will hear two long beeps confirming deletion of all data Command 0000 To change the password While in the programming mode enter 10 new password four numbers This will change the password to the four new numbers you just selected To exit the programming mode press again The password is used for remote control via telephone programming and turning off the alarm at the control panel The users should keep it confidential 14 VI Installation of door window sensors Door window sensors are used for detecting the opening of a window or door When it detects the opening it will send a signal to alarm panel Attach the transmitter box to the door casing antenna vertical and the magnet to the door Avoid mounting the antenna directly next to a metal door or metal surface Place the transmitter at the
5. to register all in a single zone dedicated for the remotes Keeping these separate from other zone sensors will allow you to determine that an alarm initiated by the panic button on a remote This can be done by looking at the LED zone indicator on the control panel after an alarm event has taken place When finished enter to exit sensor registration Enter again if you are done and wish to exit programming or wait 30 seconds for the control panel to automatically exit Defense Zone Configurations Each zone can be configured to have special features Below are the configuration options While in the programming mode the below command sequence will permit changes to the configuration of a zone Command Zone number 01 06 2 X Example To put a delay on Zone 1 the command is 01 2 2 X will be 1 Immediate When a sensor is tripped in a zone with an immediate configuration the alarm panel will immediately activate the siren and dial the telephone numbers programmed 2 Delay When a sensor is tripped in a zone with a delayed configuration the alarm panel will delay the siren activation and telephone dialing sequence until after 30 seconds have passed This is a useful feature if you do not have a remote control for everyone and the alarm protection has to be turned off at the control panel Delayed configuration sensors would typically be used on a main entry in this case The control panel will beep about every second du
6. 110 Vertical 60 Working Condition Temperature 10 Deg C to 40 Deg C Humidity lt 90 Remote Control Power Supply DC12V inner DC12V battery type 23A Static Current 0 Transmission Current lt 15mA Transmission Frequency 433MHZ 0 5MHZ Transmission Distance No obstacles 80m Working Condition Temperature 10 Deg C to 40 Deg C Humidity lt 90 Please Note PSTN Alarm System PH SD55 comes as a standard package with limited accessories More sensors detectors if needed are to be bought separately The standard package components are 1 alarm control panel 1 wireless infrared motion detector 1 wireless door magnet detector 1 indoor home alarm siren 2 remote controls 1 power supply 9v dc 1 instruction manual The following sensors can be added by the user Additional wireless products available commercially include Remote controls wireless PIR motion sensors wireless door window sensors with magnets wireless gas detectors wireless smoke detectors panic buttons glass break detectors and water detectors according your specific needs All sensors should work on 433 MHz with 5211 2262 or 1527 encoding lll Explanation of the alarm system operation a Working elements This alarm system contains two main parts a control panel and some sensors When a sensor detects a breach it will send a radio signal to control panel When control panel receives the signal the ALARM LED and the LED for the zone
7. PSTN Alarm System PH SD55 Six Zone Wireless Alarm System User s Manual http www phoenixhomesecuritysystems com Table of contents No Topic Page Features of PSTN alarm system PH SD55 3 ll Technical parameters and components 4 lll Explanation of the alarm system operation 6 IV Installation of the alarm control panel 7 V Programming the alarm system 8 VI Installation of door window sensors 15 VII Alarm operation with either the remote control or the alarm panel buttons 16 VIII Receiving a call from the alarm panel 17 IX Remote operation via telephone 18 X Use of remote controls 19 Features Anti interference function The alarm can be programmed so that when someone interferes with the alarm on the same frequency the alarm panel will activate the siren Supports anti decode mode of the remote control Six programmable defense zones available with status LED s for each zone The control panel can register 99 sensors and detectors User can start the alarm to HOME or AWAY easily by pressing one key on remote control The alarm can sound a reminder when the user exits the home indicating the alarm needs to be set The alarm can be programmed to dial 6 various phone numbers when there is an alarm trip A recorded message will play when the dialed telephone is answered The alarm can arm disarm with a remote control or the keypad o
8. are at home The siren will have a short chirp if siren notification is enabled c DISARM button press it to disarm the system The siren will have two short chirps if siren notification is enabled d PANIC button press it and the siren will start to operate continuously for the siren alert time and the alarm will dial the programmed telephone numbers kkkkkkkkk 19 This manual is brought to you courtesy of Mr Leonard Lieblein http www phoenixhomesecuritysystems com contact us 20
9. ed 4 Water sensors are available to detect either broken pipes or flooding conditions 5 Panic buttons are available 6 Remote controls that are similar to an automotive keyless remote allow remote control of the alarm system IV Installation of the alarm control panel a Insert the siren connector into the siren port of control panel connect incoming telephone line to the out line port of the control panel and connect a telephone handset to the telephone port of the control panel b Connect the power supply DC plug to the power port on the alarm panel Plug the power supply into a wall outlet Press the power button to turn the system on The power status light will be blinking and sound a beep which indicates the control panel is working normally The panel will sound a beep beep beep every 30 seconds which indicates the alarm phone numbers have not been set up The beeping will disappear after a number for the alarm to dial is entered Note While registering sensors disconnect the siren to avoid activating the siren while registering sensors Attention a Try to install the alarm control panel in the center of all the alarm sensor locations Extend the antenna of the control panel positioned vertically This will give the greatest range and strongest signal reception from all sensors b The installation position of the main panel should be far away from metal objects and wireless devices c Always insu
10. el when you speak When the recording time ends you will hear two beeps The zone lights also count down near the end of the record time Every recorded message will replace a previously recorded message The message should be short and clear For example There is burglary in progress at your address To listen to the recorded message pick up the attached telephone handset and press 6 c Registering sensors or detectors with control unit Please collect all sensors or detectors including door sensors PIR detectors and gas smoke detectors and place near the control panel Make sure each has a good battery installed Switch on control panel power LED is on Each detector has its unique ID Some sensors detectors will have jumpers to set a unique code for the device If you have more than one of these in the system the jumpers should be set differently Some sensors automatically generate a code With this type you do not need to set jumpers When a sensor is tripped it will send a signal to control panel For the alarm to recognize the sensor it must be registered To trigger sensors while registering them with the control panel use the following procedures Door sensors Just remove the two parts of door sensor and remove back panel will beep and the status LED flashes which shows successful PIR Sensors You can turn the switch to on and the system will beep which shows registering was successful Then turn it to off
11. n the control panel The alarm can be armed disarmed or room listened to by calling the host phone number The phone number of control panel outside line Alarm can alert user if the telephone line is cut or shorted out Internal battery backup can continue to work for 8 10 hours when AC electrical power is lost The siren can be set to sound from 0 minutes no sound to 30 minutes ll Technical Parameters and Components Operating voltage Provided with power supply with input of 100 240VAC 50 60Hz and output of 9VDC 300ma cont 1A max Wireless receiving distance typical 2 80m Operating Frequency 433 92 MHz Operating voltage 9VDC provided by power adaptor with an input of 100 240VAC External Alarm Siren Volume 110 dB Working Condition Temperature 10 Deg C to 40 Deg C Humidity lt 90 Maximum Number of Wireless Sensor Devices 99 Wireless Door Sensor Power Supply 12V battery type 23A Static Current lt 20 uA Transmission Current lt 15mA Transmission Frequency 433MHZ 0 5MHZ Transmission Distance No obstacles 80m Magnet to Sensor Gap Distance 10 mm Working Condition Temperature 10 Deg C to 40 Deg C Humidity lt 90 Wireless PIR Motion Detector Power Supply 9V battery Static Current lt 100 uA Transmission Current lt 20mA Transmission Frequency 433MHZ 0 5MHZ Transmission Distance No obstacles 80m Detect Speed 0 83 3m s Detect Distance 5 12m Detect Range Horizontal
12. of the sensor will illuminate the control panel will activate the 110dB siren to alert you or neighbors as to an entry The siren may also be turned off or disconnected if so desired as to not alert the intruder that he has tripped an alarm The alarm panel also dials up to 6 phone numbers and plays a recorded message when answered Each of the phone numbers will be called in the order it was programmed The alarm will repeat the sequence a total of 3 times if the alarm is not disarmed by the user After the alarm is disabled the alarm and zone LED s will continue to flash indicating the breach This will continue until the alarm is armed again b Functions of different sensors detectors and remote controls that are commercially available 1 Window door sensors detect the opening of doors or windows When the magnet is moved away from the sensor it will send signal to control panel 2 PIR Sensors detect the motion of objects with infrared heat such as the human body 3 Smoke gas detectors detect smoke or gas leak When detecting smoke or gas it will send a signal to control panel These type sensors should be placed in a zone that operates in a panic mode thus tripping the alarm whether is armed or not There are two types of smoke detectors that are readily available The photoelectric type is best for detecting smoldering fires The ionization type is best for detecting flash fires with flames For maximum protection both should be us
13. panel is armed in the Away mode but does not work in the Home mode Deleting all coded information to register a new set of sensors Under the status of registering input 7 It will sound beep beep two times to confirm that all coded information has been deleted 11 Enable disable the reminder to set the alarm If you program a reminder for a defense zone the control panel will beep for three times to remind users to set the alarm when a sensor in the zone it tripped Example of usage would be on the front door to your building When you open the door the three beeps will remind you to set the alarm It can also be used to know when someone is coming in a door or room when the alarm is not set provided the user is in close proximity to the alarm panel When used on a zone that is configured for HOME the sensors in the zone will cause the control panel to beep 3 times when tripped The reminder will also sound when a HOME configured sensor is tripped while the alarm is armed in the HOME mode Command while in programming mode Enable reminder Zone No 71 Disable reminder Zone No 70 Enable disable the anti interference function If enabled and someone attempts to jam the control panel with a radio transmitter on the same frequency the control panel will activate the siren but it will not dial the phone numbers programmed in the alarm Command while in programming mode Enable 17 1 Disable 17 0
14. re the incoming telephone line is connected to the control panel so that it can dial out when there is an alarm d The alarm panel should be located in a dry interior area hidden from view This alarm is NOT designed for outside use V Programming the alarm system Before programming enter the passwords and The factory default is 1234 Two beeps will indicate that the password entry was successful Four short beeps indicate a failed entry in which the password must be entered again To exit the programming state press If no programming entry is made in 30 seconds the panel will automatically exit the programming state To get rid of the beep beep beep every 30 seconds when you first get the alarm program at least one telephone number a Programming telephone numbers that will be dialed when there is an alarm While in the programming mode use the following commands to program each number 31 the 1st User phone number 32 the 2nd User phone number 33 the 3rd User phone number 34 the 4th User phone number 35 the 5th User phone number 36 the 6th User phone number Note To remove a phone number reprogram and leave the number blank For example for the third number enter 33 b Recording an alarm message After entering the programming state input 6 to record a 10 second message that is played when the alarm panel calls a number During this message place your mouth about 15cm 6 inches from the pan
15. ring the 30 second delay 10 3 Panic When a sensor is tripped in a zone with a panic configuration the alarm panel will immediately activate the siren and dial the telephone numbers programmed regardless of whether the control panel is armed or disarmed This configuration should be used for panic buttons fire smoke detectors gas detectors flooding detectors or any other detector requiring an immediate response at all times whether the alarm is armed or not 4 Home A sensor configured for home will allow users to pass by motion detectors open internal doors Such as a door to an attached garage without tripping the alarm Perimeter sensors will still be active when the alarm panel is armed with the Home button This is typically used at night when your family is in the house and you wish to secure the perimeter doors and windows of the house 5 De activated This feature allows a sensor to be made inactive This might be helpful if you have a motion detector in a room or garage where an animal has been temporarily placed Configuration programming example If you want the second defense zone to be a Home configuration you can input 0225 Factory configuration settings Usually we setup the door window sensors installed in windows or doors as Immediate The detectors in this area will activate alarm in either the Away or Home modes The wireless PIR detector is set in a Home configuration It will be active when the alarm
16. top of the door casing if the door is metal If the sensor is in an area where warm temperatures are common the double sided sticky tape used to mount the transmitter may release It is recommended that you use other non metallic hardware to mount the transmitter and screws to mount the magnet Caution A Magnets should be mounted as close as possible 10mm or less to the transmitter box side opposite of the antenna The magnetic switch in the transmitter is located on that side B In order to insure a strong signal at the panel the antenna should be pulled out and positioned vertically C If the indicator light of door sensor is blinking this indicates a low battery condition The battery should be replaced as soon as possible Installation of Wireless PIR motion Sensors PIR Sensors are used for detecting if someone moves within in a certain area Attach the sensor to the wall 2 2 2 meters 6 5 7 2 ft high and adjust the position to make it face to area being monitored 15 Vil Alarm operation with either the remote control or the alarm panel buttons AWAY alarm activation Momentarily press on the remote control or press the AWAY button on the alarm panel for 2 seconds The alarm panel will beep and the AWAY status LED will begin to flash for 30 seconds allowing sufficient time to exit the building If you continue to hold the AWAY button on the remote the alarm panel will beep 5 times and enter the HOME alarm sta
17. tus HOME alarm activation Press on the remote or press the HOME button on the alarm panel for 2 seconds the alarm panel will beep and the HOME status LED will illuminate immediately In this mode the detectors configured for Home will not activate the alarm DISARM Press on remote control or input the password DISARM on control panel the system will disarm PANIC Emergency Help In apanic or emergency situation you can press alarm panel on remote control or momentarily press the PANIC button on the Note Please allow approximately 10 seconds between disarming and entering into another operation The alarm panel needs time to reset 16 VIII Receiving a call from the alarm panel When a sensor is tripped the alarm panel will activate the siren if connected and enabled either immediately or after 30 seconds if the sensor configuration is delayed and dial the programmed telephone numbers The ALARM status LED on the alarm panel will be illuminated When a user answers the phone they have the following features available a Press to be able to listen to the area around the alarm control panel for period of 30 seconds b Press to confirm that you have already received notification of the alarm This will stop the alarm from dialing unless a sensor is tripped again Then the alarm will start calling again This can be useful in determining if the trip is a nuisance trip for instance by rodents When