Home
On-Site Alarm System
Contents
1. Strong light interferes with detection sensitivity In addition complicated situations such as traffic flow stream of people also should be avoided 24 25 Avoid facing to or positioning close to heat cold sources Heat cold sources such as heat extraction units heaters air conditioner microwave oven refrigerator which may cause false triggering should be avoided Avoid facing to swinging objects Swinging objects may also trigger false triggering Besides if there are two detectors covering the save scope adjust the locations to prevent cross interference Connecting and Deleting Accessories Accessories need to be paired to the siren so that the siren can receive signals from them and sound the alarm Accessories in the kit have been paired to the siren before delivery and ready for use If the siren does not alarm when detectors are triggered please pair them again Accessories purchased separately must be paired to the siren before use Pairing the Remote Control Press the connect button on the siren Press the connect button on the siren it beeps once 3 seconds ater it beeps once again and the strobe flashes indicating the siren is ready for pairing Press any button on the remote control Press any button on the remote control the siren beeps once indicating successful pairing Note If the siren beeps twice it indicates the remote control has been
2. Warning in most cases it is an electronic device Incorrect or improper uses of the device may result in serious injuries Repairing the unit must be done by smanos qualified personnel The warranty expires immediately if the unit is repaired and or when the product is misused 38 39 Terms of Warranty Notes The three year warranty applies to all smanos products unless otherwise specified at the time of purchase When buying a second hand smanos product the product warranty remains measured from the time it was bought by the original owner Power supplies batteries antennas and all other products integrated in or directly connected with the main product or products that may reasonably assumed to have a different wear pattern than the main product are therefore not covered by the smanos guarantee The warranty doesn t apply when incorrect or improper use external influences and or opening of the housing has been done by parties other than smanos Sensor Sensor type Name Group Normal Home 24 7 Zone1 Magnet contact SMANOS HOLDING LTD Zone 2 Motion detector Jacobus Spijkerdreef 386 Zone 3 2132 PZ Hoofddorp Zone 4 the Netherlands Zone5 www smanos com Zone 6 Zone 7 Zone 8 Zoneg Zone Zone Zone Zone Zone Zone 3 U HR WlNnlre o Zone 40 CHUANGO FRES WS 105 ABF AK VLRA z
3. switches to the testing mode and sustains Atter making sure the EE CTT Wome normally do as follows or 3 minutes Walk in the detection scope and observe the LED When i x uman movement is detected the LED blinks once 1 Choose a suitable installation location t is recommended to mount it at the height of 2m from the ground For installation notices please see page 23 25 ee I 2 Fix the detector 4 Adjust the angle Adjust the bracket angle to achieve the best detection effect Fix the installation bracket on the wall with screws and then fit the groove at the back of the detector on the bracket For the detector of this model you can stick it at the corner with double sided tapes ae aE 3 6 ean Side view Top view 22 23 Installation Notices Pay attention to the following during installation Mount the detector to a location close to the entry or exit The detector aims at preventing intrusion Detecting human movement at the entry or exit is critical for security Mount the detector in a proper angle The installation angle affects sensitivity directly The sensitivity is optimal when the walk direction is vertical to the infrared direction Choose the best location and angle according to the actual situation and detection scope diagram Avoid facing to glass windows or doors
4. 19 Power Saving Mode The product features power saving design If the detector detects human movement twice in 3 minutes it will switch to the sleeping state to save power At this time the LED will not blink and no alarm After no movement within the next 3 minutes the detector switches back to the working state automatically Case 1 Case 2 Initial star then guard Press the test button and then guard 3 minutes later Sleep after detecting human movement twice No human movement within 3 minutes Switch from sleep to guard Note After the detector is in the sleeping state ensure no human movement within 3 minutes otherwise the detector remains sleeping In the sleeping state it is recommended that you leave the room after arming the system Ensure no human movement in 3 minutes Then go into the room the siren alarms immediately Detection Scope Top view Side view Test the PIR Motion Detector This is to test whether the PIR detector works normally 1 Remove the insulating strip 2 Arm the system Press the Arm button on the remote control The system is armed Remove the insulating strip 3 Trigger an alarm Keep pressing the test button at the back until the siren sounds It indicates that the PIR motion detector is connected to the siren 20 Install the PIR Motion Detector 3 Test the PIR motion detector Press the test button at the back It
5. A Alarm Current lt 100mA Radio Frequency 868MHz Housing Material PC ABS plastic Operating Condition Temperature 10 C 55 C Relative Humidity lt 80 non condensing Dimensions LxWxH 90 x 90 x 42 2mm Not include plug part 33 RE2300 Remote Control Power Supply DC 3V CR2032 lithium cell battery x 1 Transmit Current lt 9 5 mA Transmitting Distance lt 80 m open area no interference Radio Frequency 868MHz Housing Material PC ABS plastic Operating Condition Temperature 10 C 55 C Relative Humidity lt 80 non condensing Dimensions LxWxH 71 x 38x12 mm 34 DS2300 Door Window Contact Power Supply DC 3V CR2032 lithium cell battery x 2 Static Current s 114A Alarm Current lt 10 5 mA Transmitting Distance lt 80 m open area no interference Radio Freguency 868MHz Housing Material ABS plastic Operating Condition Temperature 10 C 55 C Relative Humidity lt 80 non condensing Transmitter Dimensions L x W x H 72 5 x 28 x 10 mm Magnet Dimensions LxWxH 58 x 14x 9 5 mm 35 MD2300 PIR Motion Detector Power Supply DC 3V 1 5V AA battery x 2 Static Current lt 50 uA Alarm Current lt 11 MA Detection Scope 8m 110 Transmitting Distance lt 80 m open area no interference Radio Frequency 868MHz Housing Material ABS plastic Operating Condition Temperature 10 55 C Relative Humidity lt 80 non condensing Dete
6. cessories The zone mode of wireless accessory includes normal zone home mode zone or 24 H zone Normal Zone In arm or home mode status the system will alarm immediately once the sensors in normal zone is triggered Home Mode Zone In home mode status the system will not alarm once the sensor in home mode zone is triggered 24 H Zone In any condition the system will alarm immediately once the 24 H zone detector is triggered Sensor Default Zone MD2300 PIR Motion Detector Home Mode Zone DS2300 Door Window Contact Normal Zone Note The default zone setting of smoke de beam sensors are 24 H zone 29 ector gas detector or outdoor Entry and Exit Delay f you do not want to take the remote control entry and exit delay time can be set Press the connect button twice delaying for 30 seconds Press the connect button for three times delaying for 60 seconds Press the connect button for four times disabling the function After setup if you arm the system the siren beeps once every 5 seconds until it goes to arm state If the sensors are triggered the siren will sound the alarm after the delay time Note Press the Arm button on the remote control twice The system switches to arm state immediately 30 31 Act as an Accessory Kit If user purchased our alarm system before S105 can act as an accessory kit working with the control panel af
7. ctor Dimensions LxWxH 101 5 x 59 x 37 5 mm Bracket Dimensions Lx Wx H 60 x 29 x 27 mm 36 Disclaimer smanos have reviewed this manual thoroughly in order to make it an easy to use guide for this product All statements technical information recommendations in this manual are believed reliable but the accuracy and completeness are not guaranteed or warranted The specifications and information regarding the products in this document are subject to change without notice Photocopy copy reproduction translation to any language modification storage in a retrieval system or retransmission in any form or by any means electronic mechanical or otherwise is strictly prohibited without prior written permission In no event shall smanos be liable for any indirect special incidental or consequential damages including without limitation lost profits or loss or damage to data arising out of the use or inability to use this document even if smanos has been advised of the possibility of such damages A Caution and Warnings Due to laws and regulations determined by the Euopean Parliament some wireless devices may be subject to restrictions on its use in certain European countries In some EU Member States the use of eguipment are prohibited Contact your local government for more information on these restrictions Always follow the instructions in the manual especially when it concerns devices which need to be assembled
8. it x 1 2pcs for door window Detectorx1 For PIR sensor processing technology and intelligent analysis algorithm contact 2pcs for PIR effective resolution of interfering signal and human sensor movement signal preventing false alarm It can detect o the temperature and movement of human bodies within the 8 meter cone space When detecting human movement twice in 3 minutes it switches to the power saving mode automatically After 3 minutes of no human movement it switches to the working state User Manual x 1 Quick Guide x1 On Site Alarm Panel Alarm Panel Overview Power button connect button Siren and Strobe Light Strobe light Status Siren Strobe Light Arm or Home Arm Beeps once Flashes once and then on Disarm Beeps twice Flashes twice and then off Mute Arm No beep Lights on Mute Disarm No beep Lights off Power On The siren is powered off by default Plug the siren into a power outlet Press the power button It beeps once indicating power is on Power Off After the siren is powered on press the power button once Then press and hold the power button for 6 seconds until a beep is heard indicating power is off Test and Install Accessories Accessories in this kit can work only with our control panels Remote Control RE2300 remote control is dainty and delicate easy to carry It can be attached to your key ring or ju
9. net This product is not suitable for shutter door please purchase shutter door sensor for your use 15 16 17 Test and Install the PIR Motion Detector The detector adopts digital dual core fuzzy logic control processing technology and intelligent analysis algorithm effective resolution of interfering signal and human movement signal preventing false alarm It features automatic temperature compensation and resistance to flow technology adapting to environmental and temperature change It can detect human movement within the 8 meter cone space suitable for halls hallways etc Overview Test Button Detection Double sided Lens Tape Stick Place LED Indicator Bracket Slot LED Indication Blinks continuously Self testing Blinks once Intrusion is detected Blinks twice 3 minutes testing mode is finished enters power saving mode Blinks once per 3 seconds Low battery indication please change the batteries immediately PCB Layout Tamper Switch mth poemen Infrared Sensor 947 AS L VV off LED Indicator Note When tamper switch is triggered the siren will alarm immediately Working Mode Testing Mode After self testing press the test button the detector switches to the testing mode and detects once every 10 seconds It triggers an alarm After 3 minutes the LED blinks twice and the detector switches to the power saving mode 18
10. our home under all round protection To experience this wonderful product please follow the instructions in the user manual Please read this manual carefully before using Please kindly keep this user manual for your reference when necessary Features 100 wireless configuration easy to use Compact and streamline design One button pairing Work as accessory or standalone alarm panel Built in battery for 8 hour standby Mute operation Nightlight function Support 40 wireless accessories including remote control Built in 1 000 000 RF codes combination maintains high reliability In the Box DS2300 Door Window Contact x1 The contact can be used for doors windows or other devices that can be opened or closed Once a window or door is opened the transmitter and magnet are separated thesystem will trigger an alarm RE2300 Remote Control x 2 It s convenient to carry With the remote control you can arm disarm the system set home mode perform SS1005 Alarm Panel x 1 mute arm disarm make an emergency call The alarm panel receives and processes signals from wireless accessories When the accessory is triggered the panel will alarm and the strobe light will flash to deter intruders With plug in design it is powered by AC 100 240V by plugging it into a wall outlet q S MD2300 PIR Motion Detector x 1 2 The detector adopts digital dual core fuzzy logic control Double sided Tape x 4 Bracket for PIR Screw K
11. paired before 26 Pairing the Door Window Contact Press the connect button on the siren Press the connect button on the siren it beeps once 3 seconds ater it beeps once again and the strobe flashes indicating the siren is ready for pairing Separate the transmitter and magnet 27 ake sure the triangle marks close to each other and within the range of 1cm and then separate them with the space more than 2 cm The siren beeps once indicates successful pairing gt 2m 3 Note If the siren beeps twice it indicates the door window contact has been paired before Pairing the PIR Motion Detector Press the connect button on the siren Press the connect button on the siren it beeps once 3 seconds ater it beeps once again and the strobe flashes indicating the siren is ready for pairing Press the test button on the PIR motion detector Press the test button at the back of the PIR motion detector The siren beeps once indicating successful pairing Note If the siren beeps twice it indicates the PIR motion detector has been paired before Deleting Accessories Deleting accessories is to disconnect accessories from the siren After that the siren cannot receive signals from accessories nor trigger alarms Press and hold the connect button on the siren for 6 seconds the siren beeps once and the strobe flashes twice indicating all the accessories are deleted 28 Zone Mode of Wireless Ac
12. separated or the tamper switch is pressed the system will trigger an alarm Overview LED Indicator Tamper Switch Transmitter J nes Magnet Front side Back side LED Indication Blinks once Intruder is detected Blinks once per 3 seconds after triggered Low battery Replace the battery as soon as possible 13 PCB Layout Tamper Switch Test the Door Window Contact CR2032 Lithium Cell Battery This is to test whether the contact can work properly 1 Remove the insulating strip The contact works immediately 14 2 Pay attention to the direction Install the Door Window Contact Make sure the triangle marks on the side of the transmitter and magnet are There are triangle marks on the side of the transmitter and magnet Make sure g 9 close to each other and within the range of 1 cm when installing the triangle marks is close to each other and within the range of 1 cm 9 3 Secure the contact with double sided tapes Secure the transmitter and magnet on the desired locations with double sided tapes 3 Test the door window contact Press the Arm 8 button The system switches to the arm state Separate the transmitter and magnet with the space more than 2 cm The LED on the transmitter blinks once then the siren alarms This means the contact works properly Note If this product is installed on gt 2cm gt metal door place spacers under the transmitter and mag
13. smanos 5105 On Site Alarm System O e User Manual Printed in China 2014 smanos All rights reserved PA OI S105 EN 1404 V1 0 Table of Contents Working Mode Product Introduction Led Test the PIR Motion Detector Install the PIR Motion Detector Foreword S 7 Installation Notices Features In the Box Connecting and Deleting Accessories 26 28 Pairing the Remote Control On Site Alarm Panel 5 6 9 Pairing the Door Window Contact Alarm Panel Overview Pairing the PIR Motion Detector Power On Deleting Accessories Power Off n A Zone Setting For Wireless Accessories 29 Test and Install Accessories Feds Entry and Exit Delay 30 Remote Control Act as an Accessories Kit sla3Z Overview Arm Away Arm Pairing the Siren to the Control Panel Dii Pairing Other Wireless Detector to the Control Panel Home Mode Part Arm Deleting the Siren from the Control Panel sos Deleting Accessories from the Control Panel Mute Operation oa A st Specifications 33 36 Nightlight On Off Test and Install the Door Window Contact Disclaimer 37 Overview S i A Caution and Warnings 38 Test the Door Window Contact Install the Door Window Contact Terms of Warranty 39 Test and Install the PIR Motion Detector Notes 40 Overview Product Introduction Foreword Dear Customers Thank you for purchasing S105 This product is a totally plug amp play wireless home security solution It features automatic pairing to various accessories putting y
14. st put into your pockets or purses When you are about to exit or entry the house you can use it to arm or disarm the system In case of any emergency just press the SOS button the alarm will be activated immediately Overview LED Indicator Guide Point For ANTI nooo The Blind Metal Ring LED Indication LED blinks once Armed or in home mode LED blinks once Disarmed x LEDs blinks once SOS Arm Away Arm n arm state the system will trigger an alarm when detecting intrusion Press the Arm button The siren beeps once indicating the system is in he arm state ote If you do not want to take the remote control entry and exit delay time can be set For related definition and setting please refer to page 29 Disarm y In disarm state the detectors except those accessories in the 24 hour zone will not trigger an alarm when detecting intrusion Press the Disarm button The siren beeps twice indicating the system is in disarm state Note If entry and exit delay is set you can enter your home directly in the arm state then disarm the system within the delay time No alarm will be triggered in this case If you disarm the system after the delay time the system will trigger an alarm Home Mode Part Arm In home mode detectors that set in home zone are in disarm state the other detectors are still in arm state That is you can move freely in
15. t ED fall RS MA 210X142mm 80S 105X142mm I 2 141347 44P PA OI 05S EN 1404 V1 0 it MB NEE
16. ter successful pairing Pairing the Siren to the Control Panel Press the connect button on the siren Press the connect button on the siren it beeps once 3 seconds ater it beeps once again and the strobe flashes indicating the siren is ready for pairing Press the Arm or SOS button on the control Panel Press the Arm or SOS button on the control panel the siren beeps once indicating successful pairing Exit the pairing status Press the connect button on the siren it beeps once exiting the pairing status Test whether the siren has been paired Press the Arm button on the remote control If the siren and control panel both beep once it indicates the pairing succeeds If not please pair them again Pairing Other Wireless Detectors to the Control Panel After control panel enters its pairing status please refer to its user manual trigger the wireless detector the control panel beeps once to indicate successfully pairing Deleting the Siren from the Control Panel Press and hold the connect button on the siren for 6 seconds The siren beeps once and the strobe flashes twice the siren is deleted from the control panel Deleting Accessories from the Control Panel Please refer to the manual of control panel 32 Specifications SS1005 On Site Alarm Panel Mini Strobe Siren Power Supply AC 100V 240V 50 60 Hz Volume 90dB Backup Battery 3 7V 600mAh lithium battery Static Current s 13m
17. the home zone however the rest areas are still being protected Press the Stay 8 button 3 seconds later the siren beeps once indicating he system is in home mode state Note The PIR detector is set in home zone by default That is the PIR detector will not trigger an alarm after you press the Stay button The zones include home zone normal zone 24 hour zone For details of each zone please refer to page 30 SOS 505 In case of emergency you can press the SOS button Whenever you press the SOS button on the remote control the siren will alarm immediately 10 11 Mute Operation 000 You can arm and disarm the system silently Press and hold the Stay button for 1 second and then press the Arm J button within 3 seconds The system is armed silently Press and hold the Stay 8 button for 1 second and then press the Disarm button within 3 seconds The system is disarmed silently Nightlight On Off 9 Press the Stay button twice the siren switches to home mode silently and the nightlight is on Press the Disarm button the siren disarms and switches off the nightlight 1 2 Test and Install the Door Window Contact The contact contains a transmitter and a magnet which can be mounted on a door window or any object that can be opened or closed When the transmitter and magnet are