1. In the event of an alarm the external siren is not set off for internally armed set to 0 The state is internally armed therefore triggering of the external siren for externally armed is not possible set to f a smoke detector is triggered no alarm is effected via the external siren set to 0 Ifasabotage contact is triggered no alarm is effected via the external siren set to 0 In the event of an attack no alarm is effected via the external siren set to 0 Table containing the factory settings for the externally armed state Externally armed state Alarm when Alarm when Alarm rita Alarm upon Alarm upon int armed ext armed Smoke sabotage attack detection The state is externally armed therefore triggering of the external siren for internally armed is not possible set to In the event of an alarm the external siren is set off for externally armed set to 1 If a smoke detector is triggered the alarm is effected via the external siren set to 1 Ifa sabotage contact is triggered the alarm is effected via the external siren set to 1 In the event of an attack the alarm is effected via the external siren set to 1 RS Observe these three tables when you change the settings See the next page 85 You can change the conditions for setting off the alarm as follows You
2. buttons to select the sensors menu sensors e Confirm your selection by briefly pressing the OK button sensors add Using the 4 and buttons select the sensors name menu as shown sensors in the figure on the right name e Confirm your selection by briefly pressing the OK button contact 1 The first sensor that was registered with the alarm base station is livingr w1 displayed 102 Keep pressing the gt button until line 1 is displayed You are now in the list of all the wired alarm lines line 1 to line 4 and sabotage Select the alarm line whose name you wish to modify or enter using the 4 and buttons for example line 3 RS No name can be assigned to the sabotage line sabotage Press the OK button briefly A cursor appears on the lower line _ You can now modify or enter the name gt To enter the letters use the 2 9 buttons each of which represents several letters click through as with a mobile phone by repeatedly and quickly pressing the same button Numbers and umlauts can also be found on the buttons for instance Use the 0 button to enter a space character Special characters can be entered using the 4 and buttons You can use the Men a A button to switch between lower and upper case The cursor automatically jumps to the next position approx
3. f a smoke detector is triggered the alarm is effected via the internal siren set to 1 Ifasabotage contact is triggered the alarm is effected via the internal siren set to 1 In the event of an attack the alarm is effected via the internal siren set to 1 RS Observe these three tables when you change the settings See the next page 79 You can change the conditions for setting off the alarm as follows You must be on the main level The LCD should appear as on the right for example with the time and the date Briefly press the Menu a A button on the control unit of the FAZ 3000 Z alarm base station Use the 4 and buttons to select the int siren menu internal siren Confirm your selection by briefly pressing the OK button trigger appears at the bottom of the LCD alarm trigger Confirm your selection by briefly pressing the OK button Please note the position of the cursor _ If the cursor is located pre cisely at this position at the far right you can use the 4 and buttons to switch between the three different states disarmed inter nally armed and externally armed Here the dash and number sequences correspond to the settings in the tables on pages 78 and 79 Using the C and gt buttons you can select the required entry position cursor _ is located beneath the s
4. alarm dialler dials the programmed telephone number numbers the user dials the alarm dialler answer after X ringtones X 1 10 3 Setting on dial remote control is possible if alarm dialler dials the programmed telephone number numbers the user cannot call the alarm dialler remote control only during alarm dialling To set proceed as follows You must be on the main level The LCD should appear as on the right for example with the time and the date Briefly press the Menu a A button on the control unit of the FAZ 3000 Z alarm base station Use the 4 and buttons to select the al dialer menu Confirm your selection by briefly pressing the OK button Select the remote menu using the 4 and Y buttons remote con trol Confirm your selection by briefly pressing the OK button In the figure on the right the remote control is switched off off Now the various settings can be carried out using the 4 and Y buttons see above of fF Remote control is switched off L ringtone 10 ringtone Answer after X ringtones X 1 10 on dial Remote control only during alarm dialling Pressing the OK button applies the setting Exit the menu by pressing the C button twice This returns you to the normal display mode main level 96 disarm 18 10 23 02
5. buttons and proceed as described above press the OK button to enter the telephone number Otherwise you can exit the menu by pressing the C button twice This returns you to the normal display mode main level disarm 12 10 18 02 troubles al dialer al dialer trigger al dialer number 1 01234 56789 9876_ al dialer number 1 al dialer number 2 disarm 12 20 18 02 93 4 Dialout number The alarm dialler can also of course be connected to a telephone system s extension Depending on the telephone system used it may be necessary to first dial a 0 for the dialout number This can be set in the alarm base station RS Some telephone systems allow a so called automatic dialout number to be programmed For this check the telephone system s user manual Activate the dialout number either on the alarm base station or the telephone system The dialout number using the FAZ 3000 2 alarm base station is only possible using the prefix 0 zero If for example your telephone system requires a 1 or 2 etc then this should be programmed as a telephone number with a subsequent pause See page 93 To set the dialout number proceed as follows You must be on the main level The LCD should appear as on the right disarm for example with the time and the date 15 22 23 02 Briefly pres
6. ccceeeeeeeeeee 104 DiSCIAIMED ATETEA TT TT TTT ITAIT 106 Information on the range s sssssssssssusssunssennnnnnnnunnnnnnnnunnnnnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnne 107 SNDNS POS aliysctas es iseni aee a aeo iae ee tee cee atic tematic ods aeii aa st eS 108 a General information aera ianea Mane kiana a e a aad 108 b Battery and rechargeable battery disposal c cceccceceeeeeeeeeeeeeeeeeeeeeeeneeeesaees 108 acd APS Ge a oL EE E A AE A A T TAT 109 Technical specifications ssssssssssensssnssnnnnsnnnnnnnennnnnnnnnnnnnnnnennnnnnnnnnnnnnnnennnnnnnnnnnn na 111 a FAZ 3000 Z alarm base station 111 b FAZ 3000 FB 2 remote control we 111 c FAZ 3000 TF 2 door window detector 111 d FAZ 3000 PIR 2 PIR motion detector cceeeeeeceeeeceeeeeeeeeeeeeeeeseeeeneeeeareereeees 111 Brief iNStructiONns oo cece eceeceeeceseceeseeeesessceesceeseesscessceeseesseessoesssessneseonesseseees 112 a Registering a new sensor device with the alarm base station 0 112 b Replacing the batteries of a sensor device ceeeecceeeeeeeteeeeeeeeteeeeeeeeeeteneeeteaeees 112 c Replacing the alarm base station s batteries ceeeceeeeeeeeeeeeeteeeeeeeeeeeeeeeaes 112 d Changing the FAZ 3000 FB 2 remote Control s code ccceeeteeeeeteeeeeeeeeeee 113 e Using the FAZ 3000 FB 2 remote control to set off an attack alarm 113
7. int int FAZRM child 1 kitchen ext FAZ TF ext FAZ TF Figure 10 RS The assignment int internal FAZ 3000 Z menu setting Intern Y or ext external setting Intern N is explained on pages 18 and 46 For safety reasons the FAZ3000 Z alarm base station has been installed in the utility room To protect the exterior of the building internally armed all windows and exterior doors have been protected using a FAZ 3000TF 2 door window detector assignment external setting Intern N closure group for the sensors on the entrance door For increased security during periods of absence externally armed each room is equipped with a PIR motion detector assignment internal menu setting Intern Y The garage has been protected using a PIR motion detector and the summer house has been protected using a door window detector assignment external in each case menu setting Intern N The system is armed using the FAZ 3000 FB 2 remote control used for the garage from inside the car for example or using the FAZ 3000 SE 2 wireless activation switch directly at the entrance door A FAZ 3000 RM smoke detector has been installed in the kitchen Asiren witha flashing light which is mounted to the exterior of the house
8. Alarm triggering Normal operation with external power supply Onnan 12 15 1 61 In the event of a power outage back up op oa TY ry E E E eration using 8 AA batteries I t S E E X ALARMZENTRALE w n Sabotage contact alarm when casing is E u opened TT J gee a Figure 1 b FAZ 3000 FB 2 wireless remote control e Arming disarming the alarm base station Integrated panic function thus also suitable as an emergency call transmitter for endangered persons for example cashiers petrol station attendants etc In the event of an attack the alarm can be set off regardless of the location Due to its compact size it can be attached to a key chain Battery operation 1 x CR2016 button cell Dimensions 40mm x 52mm x 11mm W x H x D Figure 2 13 c FAZ 3000 TF 2 wireless door window detector e Monitoring of doors and windows via the supplied magnets can be mounted to the left or to the right of the detector Can be mounted to a door or a window for example e Monitoring of objects that need to be protected against unau thorised removal pictures works of art and so on e Option to connect additional external magnet sensors NC contact normally closed Option to connect glass break sensor NO contact NO nor mally open this is always active irrespective of the disarmed internally armed or externally armed setting of the alarm base station e
9. Declaration of conformity DOC ccceccesseeeseeeeseeeeeeeeeeeeeeeeeeeeseeeeeseeeeeeeeeeeeneeees 114 1 Prescribed use The FAZ 3000 wireless alarm system and its numerous different components see pages 13 to 16 serve to protect your property for example your apartment house garage weekend house and so on Actuarially we are talking here about small risks The FAZ 3000 wireless alarm system is not suitable for the kind of mid sized and higher risks that arise in commercial protection for example commercial premises industrial plants The alarm base station signals unauthorised entry by switching outputs to which you can connect optical acoustic or silent signal transmitters The product should only be used in closed indoor rooms Please note all the further features and characteristics of the product which are described in this user manual See pages 13 to 20 for example Any use other than the one described above is not permitted and may damage the product This can also increase the risk of short circuit fire electric shock etc No part of the product may be modified or adapted Please observe all the safety instructions in this user manual 2 Scope of delivery a FAZ 3000 Z wireless alarm base station item no 75 03 31 Alarm base station e Power supply e Assembly material e User manual b Wireless alarm base station complete set item no 75 03 30 e FAZ
10. Insert 3 AA batteries with the correct polarity into the three battery e o compartments See figure 34 The sensor contacts the alarm base station by sending a radio signal The sensor s LED lights up briefly and the base station emits a short signal tone to confirm reception RS The sensor will not be recognised by the alarm base sta tion if you inadvertently inserted batteries during the instal lation In this case remove the batteries wait a few seconds and re insert the batteries with the correct polarity The alarm base station should now recognise the sensor Figure 34 Replace the battery compartment cover Finally clip the PIR motion detector into the holder Do not use force when doing this e Return to the alarm base station The LCD s display has changed See motion 2 the figure on the right The number 2 is the consecutive sensor number and not the second PIR motion detector for instance e Usethe buttons on the alarm base station to enter the name of the sensor motion 2 garage in the example on the right garage_ 50 gt To enter the letters use the 2 9 buttons each of which represents several letters click through as with a mobile phone by repeatedly and quickly pressing the same button gt Numbers and umlauts can also be found on the buttons for ins
11. For safety reasons if a sabotage contact is triggered the alarm is also set off via the internal siren for the disarmed state set to 1 e Forsafety reasons during an attack the alarm is also set off via the internal siren for the disarmed state set to 1 78 Table containing the factory settings for the internally armed state Internally armed state Alarm when Alarm when Alarm upon Alarm upon Alarm upon int armed ext armed detocion sabotage attack ae In the event of an alarm the internal siren is set off for internally armed set to 1 State is internally armed therefore triggering is not possible for externally armed set to If a smoke detector is triggered the alarm is effected via the internal siren set to 1 Ifasabotage contact is triggered the alarm is effected via the internal siren set to 1 In the case of an attack the alarm is effected via the internal siren set to 1 Table containing the factory settings for the externally armed state Externally armed state Alarm when Alarm when Alarm upori Alarm upon Alarm upon int armed ext armed detection sabotage attack State is externally armed therefore triggering is not possible for internally armed set to In the event of an alarm the internal siren is set off for externally armed set to 1
12. ccccceeeeeeeeeeeeeeeeeeeeseeeseneeeeneeeeeaeeess 13 c FAZ 3000 TF 2 wireless door window detector s eesesseseiesrierersrriesrreerrseres 14 d FAZ 3000 PIR 2 wireless PIR motion detector cccececeeceeeeeeeeeeeeeeeeeeseneeeeenees 14 e FAZ 3000 RM wireless smoke detector cceccccceeeeeeeeeeeeeeeeeeeeeeeeeseeeeeseneeeseaees 15 f FAZ 3000 SI 2 wireless siren control eccceeeseeceeeeeeeeeeseeeeeeeeeeeeeseeeeeseneeeeaees 15 g FAZ 3000 SE 2 wireless activation SWItCH sssssssesressriesrreerrssrreerrsrrrnsrrnesnnes 15 h FAZ 3000 AW 3 wireless alarm dialler cc cceecceeeseceeeeeeeeeeeeeeeeseeeeeeneeeeseeess 16 i FAZ 3000 PC 2 wireless PC interface cccceeeseeeeeeeeeeneeeeeeeeeaeeeseneeeeneeessaeeess 16 j FAZ 3000 DCF DCF receiver eeeceeceeceeseeneeneeeesereeeeeeeeaesaeeaeeeeereeeeseeeaeeanenteanes 16 7 8 Planning the installation cccccssceessceeseeeeeeeeeeeeeeeeseeeeeseeeeeeaeeesaeeeeeaeeseeeeeeeeeeeeeeee 21 a General notes On planning ccceecceeeeeeceeeeeeeeeeeeeeeceeeeseeeeeseaeeseeaeeseaeeeseeeeseneeeeeaees 21 b Example for the protection of a bungalow cecceeeceeteneeeeeeeeeaeeeeeaeeteneeeeeaeeees 22 9 4 Installation coivs ec S Avie eaa ae haved wv cies adena aa aaea iaaa Sa dh eTa aan dadan 23 a Installing the FAZ 3000 2 wireless alarm base station 1 Notes on selecting the i
13. see the example on the right Briefly press the OK button Afterwards the name can be modified or entered gt To enter the letters use the 2 9 buttons each of which represents several letters click through as with a mobile phone by repeatedly and quickly pressing the same button gt Numbers and umlauts can also be found on the buttons for instance A gt Use the 0 button to enter a space character gt Special characters can be entered using the 4 and buttons gt You can use the Meni a A button to switch between lower and upper case gt The cursor automatically jumps to the next position approx one second after the last button was pressed gt You can use the C button to delete a character you entered by mistake Once you have entered the name you require press the OK button Afterwards you return to the sensor list You can now select another sensor to modify You can exit the name modification entry function by pressing the C button three times This returns you to the normal display mode main level 68 disarm 13 25 05 02 troubles sensors sensors add sensors name contact 1 livingr w1 smoke 3 chilD Dana smoke 3 child_ smoke 3 child Dana disarm 14 01 05 02 4 Modifying checking sensor attributes The sensor attributes internal sensor yes n
14. Confirm your selection by briefly pressing the OK button Select the DCF setup menu using the 4 and Y buttons See the figure on the right Confirm your selection by briefly pressing the OK button If synchronous appears on the lower line then the DCF time has been received correctly and the time and the date are automatically set per DCF A blinking square on the upper line indicates a received DCF signal The DCF receiver can be switched on or off using the 4 and buttons DCF active DCF receiver is switched on once switched on DCF signal is searched for it must be re synchronised first DCF off DCF receiver is switched off Pressing the OK button applies the setting Exit the menu by pressing the C button twice This returns you to the normal display mode main level disarm 17 25 05 02 troubles setup setup set time setup DCF setup DCF active J synchronous DCF off not synchr disarm 17 27 05 02 73 3 Setting the exit delay for externally armed Arming only becomes active after a set amount of time basic setting is 30 seconds but can be set to a value between 10 to 250 seconds This gives you enough time to leave your house without triggering the alarm once you have armed the alarm system to externally armed This adjustable time is the ti
15. Exit the menu by pressing the C button twice This returns you to the normal display mode main level disarm 12 10 18 02 troubles PC interf PC interf trigger PC interf silent al silent al no silent al yes PC interf silent al disarm 12 12 18 02 101 k The wired alarm lines The FAZ 3000 Z alarm base station has a total of five inputs that are available for connecting wired sensors and alarm lines e 4 wired alarm lines 1 wired sabotage line RS The wired alarm lines are immediately active and do not need to be registered The following settings are possible e Name Enter a name for each alarm line Attributes Allocation to a closure group set to yes or no Setting as an internal or external sensor intern Y internal sensor intern N external sensor 1 Enter or modify the names of the wired alarm lines The names of the wired alarm lines can be entered or modified retrospectively at any time as in the case of the wireless sensors names To enter the name proceed as follows e You must be on the main level The LCD should appear as on the right disarm for example with the time and the date 13 40 05 02 Briefly press the Mend a A button on the control unit of the FAZ 3000 troubles Z alarm base station e Use the 4 and
16. button to select the value you require Pressing the OK button allows you to register the next sensor for example another door window detector or PIR motion detector In order to register the remote control please turn to page 52 Press the C button three times to exit the alarm base station s reg istration mode This returns you to the normal display mode main level close N intern N close N intern Y close N intern N sensit 3 sensor 3 clear disarm 16 52 14 12 51 5 Registering the remote control The remote control must be registered during the last stage of the complete set s programming RS Up to four remote controls with different security codes can be registered with the FAZ 3000 2 alarm base station If you require further remote controls then you have to set them with one of the already available security codes This allows you to use as many remote controls as you require Please carry out the following steps Prepare the alarm base station as described on page 47 The LCD appears sensor x as shown on the right clear The same display appears if you have already registered another sensor for example the door window detector or the PIR motion detector from the complete set and you have not yet exited the registration mode by pressing the C button three times RS Here X in the upper r
17. code code ext code 123 code ext code 0000 setup code extern disarm 20 27 08 02 77 f Run test The run test menu is described in detail in section 12 b on pages 56 to 57 g Settings for the internal siren The following settings can be programmed for the FAZ 3000 2 alarm base station s internal built in siren alarm transmitter Conditions for setting off the alarm Duration e Signal duration when internal arming is confirmed e Signal duration when external arming is confirmed 1 Conditions for setting off the alarm changing the settings The conditions for triggering the built in siren in the alarm base station can be set in detail and dependent on the disarmed internally armed and externally armed states Useful settings are already preset in the factory however you can change these settings to suit your own personal requirements Table containing the factory settings for the disarmed state Disarmed state Alarm when Alarm when Alarm upon Alarm upon Alarm upon int armed ext armed ian ee attack e Itis not possible to trigger the internal siren for internally armed and externally armed because of the current disarmed state each set to For safety reasons if a smoke detector is triggered the alarm is also set off via the internal siren for the disarmed state set to 1
18. exclude specific routes from the detection area in a hall for instance Selecta suitable installation location for the PIR motion detector in the room thatis to be monitored Pull the wall ceiling bracket marked grey in figure 26 upwards in the direction of the arrow and off the base device of the PIR motion detector Figure 26 The bracket is only clipped on See figure 27 Figure 27 34 The two slotted holes A are used for mounting the device to a wall The slotted holes make it particularly easy to align the bracket vertically The central hole B is used for mounting the bracket to a ceiling Figure 28 e Position the bracket at a suitable location on a wall or on the ceiling Use a sharp pencil to mark where the bracket is to be mounted through the screw holes Depending on the type of surface you may have to drill holes and insert suitable dowels When drilling or fastening screws be careful not to damage any power supply lines gas or water pipes as this could pose a life threatening danger e Now use screws to attach the bracket to the wall or to the ceiling Do not insert the batteries yet The casing should remain open at first 35 d Preparing the FAZ 3000 FB 2 remote control One FAZ 3000 FB 2 remote control is included in the set Additional remote controls may be purchased separately The remote control has a security code which must b
19. is connected operated via the FAZ 3000 SI 2 wireless siren control not in the figure The FAZ 3000 AW 3 alarm dialler which is positioned next to the telephone connection can call stored telephone numbers and transmit information in the event of an alarm The alarm system can be conveniently configured using the FAZ 3000 PC 2 PC interface 22 9 Installation _ a Installing the FAZ 3000 2 wireless alarm base station Notes on selecting the installation location The alarm base station and the power supply should be installed and operated in a dry indoor area not in a damp cellar or a bathroom for example Ensure there is sufficient ventilation Choose a secure area so that intruders cannot quickly tamper with the device Installing the device in a lockable storeroom would be ideal The installation location should neither be immediately visible from outside the house nor from within the house After all not everyone needs to know where the alarm base station is installed Do not install the alarm base station on or near large metal objects radiators mirrors rein forced concrete walls metal doors as this can reduce the wireless range A socket 230V 50Hz must be located close to the installation location for the alarm base station s power supply If you wish to connect wired alarm lines to the alarm base station you should lay their cables up to the installation location of the alarm ba
20. one second after the last button was pressed You can use the C button to delete a character you entered by mistake Once you have entered the name you require press the OK button Afterwards you return to the alarm line list You can select a further alarm line whose name you wish to enter or modify using the 4 and Y buttons You can exit the name modification entry function by pressing the C button three times This returns you to the normal display mode main level line 1 line 3 line 3 line 3 cellarDoor_ line 3 CcellarDoor disarm 13 50 05 02 103 2 Set or modify the attributes of the wired alarm lines As in the case of the wireless sensors you can also set the sensor attributes internal sensor yes no and closure group yes no for the wired alarm lines or you can check the settings To set or check the attributes proceed as follows I You must be on the main level The LCD should appear as on the right for example with the time and the date Briefly press the Men a A button on the control unit of the FAZ 3000 Z alarm base station Use the 4 and buttons to select the Sensors menu as shown in the figure on the right Confirm your selection by briefly pressing the OK button Use the 4 and v buttons to select the sensor attributes menu C
21. set to 0 89 Table containing the factory settings for the internally armed state Internally armed state Alarm when Alarm when Alarm dpon Alarm upon Alarm upon int armed ext armed detection sabotage attack In the event of an alarm the alarm dialler is not set off for internally armed set to 0 The state is internally armed therefore triggering of the alarm dialler for externally armed is not possible set to Ifa smoke detector is triggered no alarm is effected via the alarm dialler set to 0 Ifa sabotage contact is triggered no alarm is effected via the alarm dialler set to 0 e In the event of an attack no alarm is effected via the alarm dialler set to 0 Table containing the factory settings for the externally armed state Externally armed state Alarm when Alarm when Aarm upon Alarm upon Alarm upon int armed ext armed detection sabotage attack The state is externally armed therefore triggering of the alarm dialler for internally armed is not possible set to In the event of an alarm the alarm dialler is set off for externally armed set to 1 Ifa smoke detector is triggered the alarm is effected via the alarm dialler set to 1 Ifa sabotage contact is triggered the alarm is effected via the alarm dialler set to 1 In the event of an attack th
22. voltage yet KL1 KL2 KL3 KL4 KL5 KL6 Sele VeEDSclOW S gt ap ap ap a SI2 BU1 E e Terminal strips KL1 to KLG KL1 KL2 KL3 KL4 KL5 KL6 opening BU2 im Figure 13 Power supply for wired alarm lines for example PIR detector or similar 12V max 315mA left plus right minus Difference line for sabotage Difference line for wired alarm line 1 Difference line for wired alarm line 2 Difference line for wired alarm line 3 Difference line for wired alarm line 4 BU1 connection for external power supply Round socket for external power supply 12V 500mA plus contact inside on the pin Western socket for external DCF receiver Fuse SI1 Fuse for FAZ 3000 2 power supply via BU1 250V 500mA slow blow Fuse S12 Fuse for KL1 250V 315mA slow blow BU connection for external DCF receiver 25 The four difference lines can be fitted with NC and or NO contacts Switching examples can be found on the right in figures 14 15 and 16 NC normally closed NO normally open This may involve magnet or glass break sensors safety shut off mats and so on A10kOhm resistor must be fitted at the end of the cable as a terminating resistor The total resistance of the alarm loop no alarm may lie within the 6 13 8kKOhm range In the event of an alarm th
23. Battery ien atek dey 1 x CR2016 Frequency 868 35MHz Range 2 4 sie eee Dimensions W x H x D Up to 300m free field 40mm x 52mm x 11mm c FAZ 3000 TF 2 door window detector Batteries arta a n a 3 x AAA batteries Additional when glass break detectors are used 3 x LR44 External Sensors cccccceeeeseeeeeees NC contact normally closed NO contact normally open Freq eNGy a ais eieaa a a aai 868 35MHz Range 2zssecieesintiiintes Dimensions W x H x D Up to 300m free field EE POIR 53mm x 163mm x 24mm d FAZ 3000 PIR 2 PIR motion detector Sensor characteristics 0 e Adjustable range up to 10m 90 with creep zone protection Batteries zisent ninna 3 x AA batteries Frequency 868 35MHz R ngei is ari ase Up to 300m free field Dimensions dia x H a se 55mm x 132mm 111 20 Brief instructions a Registering a new sensor device with the alarm base station These registration instructions naturally apply to normal sensors door window detector PIR motion detector or smoke detector as well as to all the other components in the FAZ 3000 wireless alarm system such as a remote control or an alarm dialler Install the sensor but do not insert the batteries yet Set the alarm base station to the sensor search mode see page 47 If you intend to register a FAZ 3000 FB 2 remote control a FAZ 3
24. Enter the access code as follows You must be on the main level The LCD should appear as on the right for example with the time and the date Briefly press the Mend a A button on the control unit of the FAZ Z alarm base station Use the 4 and buttons to select the al dialer menu Confirm your selection by briefly pressing the OK button Select the access code menu using the 4 and buttons Confirm your selection by briefly pressing the OK button The LCD shows code You can now use the number buttons to enter any four digit code for example 1234 or 9876 and so on You can use the C button to correct any incorrect entry you have made Pressing the OK button applies the setting Exit the menu by pressing the C button twice This returns you to the normal display mode main level disarm 18 10 23 02 troubles al dialer al dialer trigger al dialer access code remote code remote code 123 al dialer access code disarm 18 10 23 02 95 6 Enabling of remote control configuration of automatic call acceptance You can carry out three different settings in this menu 1 Setting of F Remote control is switched off 2 Setting 1 ringtone to 10 ringtone remote control is possible if
25. N on the upper line is now underlined Using the gt button you can select whether the door window detector belongs to the closure group Y or not N For further information see pages 20 and 46 Pressing the OK button allows you to register the next sensor for example a PIR motion detector see the next page Press the C button three times to exit the alarm base station s regis tration mode You are in the normal display mode again main level contact 1 contact 1 livingr w1 close N intern N close N intern Y close N intern Y sensor 2 clear disarm 16 45 14 12 49 4 Registering the FAZ 3000 PIR 2 PIR motion detector e Prepare the alarm base station as described on page 47 The LCD appears sensor x as shown on the right clear The same display appears if you have already registered another sensor for example the door window detector from the complete set and you have not yet exited the registration mode this is possible by pressing the button C three times RS Here X is the number of already registered sensors plus one Go to the PIR motion detector that you intend to register with the alarm base station After installing the PIR motion detector as described in section 9 c pages 32 to 35 the casing is open and the batteries have not yet been inserted
26. Setting the duration of the signal tone for when the intern scharf internal arm button is pressed If you switch from the disarmed state to the internally armed state or vice versa a signal tone confirms the switch this applies when the button is pressed on the alarm base station or remote control The duration of this tone is factory set to 1 0 seconds however you can set it to a value between 0 and 5 seconds in increments of 0 2 seconds 200ms EJ It can make sense to set the duration to 0 seconds if the alarm base station is armed in the evening and sleeping children are not to be woken up by the signal tone To set the signal tone proceed as follows You must be on the main level The LCD should appear as on the right disarm for example with the time and the date 21 47 08 02 Briefly press the Men a A button on the control unit of the FAZ 3000 troubles Z alarm base station e Use the 4 and v buttons to select the int siren internal siren int siren Confirm your selection by briefly pressing the OK button int siren trigger e Select the int conf menu using the 4 and buttons internal int siren arming confirmation See the figure on the right int conf Confirm your selection by briefly pressing the OK button int conf The signal duration that is
27. The number 1 is the consecutive sensor number and not the first door window detector for instance Use the buttons on the alarm base station to enter the name of the sensor for example livingr wT for Living room Window 1 gt To enter the letters use the 2 9 buttons each of which represents several letters click through as with a mobile phone by repeatedly and quickly pressing the same button gt Numbers and umlauts can also be found on the buttons for instance gt Use the 0 button to enter a space character gt Special characters can be entered using the 4 and buttons gt You can use the Men a A button to switch between lower and upper case gt The cursor automatically jumps to the next position approx one second after the last button was pressed gt You can use the C button to delete a character you entered by mistake Once you have entered the name you require press the OK button Use the gt button to set the door window detector as an internal sensor intern Y or an external sensor intern N jntern N External sensor alarm is set off for internally armed and externally armed jntern Y Internal sensor alarm is only set off for externally armed For more detailed information see page 46 By pressing the 4 button you can access the closure group settings the
28. again Briefly press the unscharf disarm button 4 once The alarm base station emits a signal tone and switches from the internally armed state to the disarmed state Briefly press the ext button 1 once The alarm base station emits a signal tone and switches from the disarmed state to the ex ternally armed state EJ The externally armed function serves to monitor a house when it is unoccupied which means the interior rooms are also monitored for example via PIR motion detectors If there is a trouble for example the alarm base station s batteries are empty or not inserted or if a magnetic contact is not closed for example a window is open then the arming is refused on the first press of the ext button 1 Only pressing the ext button 1 for a second time forces a switch to externally armed It is possible to close the magnetic contact later on without any problem The alarm is set off only when it is opened again Briefly press the unscharf disarm button 4 once The alarm base station switches to the disarmed state 55 b Testing the sensors To test the sensors the FAZ 3000 Z alarm base station uses the run test menu EJ In this menu the function of the individual sensors can be tested directly via the alarm base station s LCD without triggering an alarm or sabotage alarm If for example you open the c
29. currently set appears on the LCD factory set 1 0 sec to 1 0 seconds e Use the 4 and buttons to select the required signal duration You int conf can set this to a value between 0 and 5 seconds in increments of 0 2 0 4 sec seconds To make a quick setting keep the 4 or button pressed for a few seconds Pressing the OK button applies the setting int siren int conf Exit the menu by pressing the C button twice This returns you to the disarm normal display mode main level 21 55 08 02 82 4 Setting the duration of the signal tone for when the extern scharf external arm button is pressed If you switch from the disarmed state to the externally armed state or vice versa a signal tone confirms the switch this applies when the button is pressed on the alarm base station or remote control The duration of this tone is factory set to 1 0 seconds however you can set it to a value between 0 and 5 seconds in increments of 0 2 seconds 200ms After arming the alarm system the signal tone should still be audible from outside after you have left the house Therefore it may sometimes make sense to extend the duration of the signal tone To set the signal tone proceed as follows You must be on the main level The LCD should appear as on the right disarm for example with the time and the date 21 47 08 02 Briefly press the Ment a A but
30. detector is registered then registration is now com plete The alarm base station is ready to register the next sensor If there are no further sensors to register you can exit the registration proce dure by pressing the C button three times The alarm base station then returns to the main level in the normal operating mode See the figure on the right Fora PIR motion detector the display illustrated here on the right appears on the LCD for setting the response sensitivity The response sensitivity of the PIR motion detector can be set to a value between 1 and 4 whereby 4 represents the highest sensitivity The response sensitivity is factory set to 3 Use the 4 or button to select the value you require Pressing the OK button allows you to register the next sensor X is the number of the next free sensor Other sensors are registered with the alarm base station as described above If all the sensors are registered you can exit the alarm base station s registration mode by pressing the C button three times You now return to the normal display mode main level 66 sensor x clear disarm 10 25 05 02 sensit 3 sensor x clear disarm 10 35 05 02 2 Delete sensors Sensors that are no longer available for example sensors that are not required must be deleted Otherwise the alarm base station considers the lack of se
31. diallers access code for remote control via a telephone Remote control Enabling of remote control configuration of automatic call acceptance Entry of a service number SN for connecting to an emergency call centre 1 Conditions for setting off the alarm changing the settings For the alarm dialler the conditions for setting off an alarm can be set in detail and dependent on the states disarmed internally armed and externally armed Useful settings are already preset in the factory however you can change these settings to suit your own personal requirements The alarm dialler is only active while you are not at home thus for externally armed The alarm dialleris not activated for internally armed and disarmed If required however this can be changed Table containing the factory settings for the disarmed state Disarmed state Alarm when Alarm when Alarm upon Alarm upon Alarm upon int armed ext armed smoke sabotage attack detection Itis not possible to trigger the alarm dialler for internally armed and externally armed because of the current disarmed state each set to f a smoke detector is triggered no alarm is effected via the alarm dialler set to 0 f a sabotage contact is triggered no alarm is effected via the alarm dialler set to 0 In the event of an attack no alarm is effected via the alarm dialler
32. for the externally armed state Externally armed state Alarm when Alarm when Alarm upon Alarm upon Alarm upon int armed ext armed eee sabotage attack The state is externally armed therefore triggering of the PC interface for internally armed is not possible set to In the event of an alarm the PC interface is not triggered for externally armed set to 0 If a smoke detector is triggered no alarm is effected via the PC interface set to 0 f a sabotage contact is triggered no alarm is effected via the PC interface set to 0 In the event of an attack no alarm is effected via the PC interface set to 0 RS Observe these three tables when you change the settings See the next page 99 You can change the conditions for setting off the alarm as follows You must be on the main level The LCD should appear as on the right for example with the time and the date Briefly press the Menu a A button on the control unit of the FAZ 3000 Z alarm base station Use the 4 and buttons to select the PC interf PC interface menu Confirm your selection by briefly pressing the OK button Confirm your selection by briefly pressing the OK button Please note the position of the cursor _ see arrow in the figure on the right When the cursor is located precisely at this position at the far rig
33. inconspicu ously by forcefully kicking against a side entrance door or using a glass cutter to cut the glass pane in a terrace door Therefore in addition to using the components in the FAZ 3000 wireless alarm system you should of course also protect your apartment or house soundly using mechanical security fixtures such as window shutters that cannot be raised from outside Police information centres and consumer advice centres can provide you with further infor mation on this or you can go to a specialist shop or consult a skilled technician 109 Asa result of the FAZ 3000 wireless alarm system s long production time and the constant improvements made by the manufacturer several versions of the individual components now exist such as for the FAZ 3000 Z alarm base station the PIR motion detector or the remote control for example Despite all the variations in the design of the casing and the design of the enclosed circuit boards there are however no known compatibility problems Your system should therefore still function properly if you combine different versions If for example you use the predecessor of the FAZ 3000 PIR 2 PIR motion detector with this version of the FAZ 3000 2 alarm base station then only the design of its casing is different along with the resulting alternative assembly it requires The registering procedure and all the other functions for this predecessor are
34. is not entered during Figure 29 these 20 seconds the LED goes out Pressing any button activates the entry mode again for 20 Q seconds o Enter the 9 digit code using the buttons O and these cor fK CHO respond with their respective numerical values Example 142142142 After the code has been entered the LED goes out and the remote foe control is ready for use s If you need to re enter the 9 digit code keep button O ext 6 externally armed pressed for approx 5 6 seconds until the LED lights up for approx 2 seconds and then goes out Then release the button Figure 30 The LED begins to blink To enter the code proceed as described above Alternatively you can also remove the battery from the remote control for at least 1 minute Theremote controlcanbe attachedtoakey chain forexample using the loophole However the buttons may be inadvertently pressed which can lead to unintentional responses within the range of the alarm system 36 10 Initial operation and programming No matter whether you bought the set alarm base station with door window detector PIR motion detector and remote control or a single alarm base station with other accessories the separate parts should already be installed Now switch on the FAZ 3000 wireless alarm system and set it to suit your own expectations and requirements Before you start to program the device please famil
35. is not used for a longer period of time for example when stored remove the inserted batteries to prevent the batteries from leaking and causing damage 11 5 Introduction In times of rising crime rates for break ins thefts and attacks it makes sense to protect your property as well as implement fire protection using smoke detectors for example Objects such as jewellery technical equipment works of art and cash which may interest burglars are present in almost every home The retrospective installation of a comprehensive protection system in a building or an apartment involves the extensive laying of connection cables when a conventional alarm system is used Wall slots holes for cables etc Often such work is not even possible as alterations on this scale may not be carried out in rented accommodation Even in modern energy saving houses that are constructed partially from timber it is often not possible to lay cables retrospectively This is where the FAZ 3000 wireless alarm system comes into its own Thanks to radio trans mission it is particularly easy to mount and install The laying of cables is almost entirely dis pensed with the FAZ 3000 can also be subsequently extended both quickly and easily IS Please note There is no absolute protection against break in attack and theft Mostly however offenders prefer to get on with their business quietly and without attracting attention A
36. must be on the main level The LCD should appear as on the right for example with the time and the date Briefly press the Menu a A button on the control unit of the FAZ 3000 Z alarm base station Use the 4 and buttons to select the ext siren menu Confirm your selection by briefly pressing the OK button The LCD dis plays trigger alarm trigger Confirm your selection by briefly pressing the OK button Please note the position of the cursor _ If the cursor is located pre cisely at this position at the far right you can use the 4 and Y buttons to switch between the three different states disarmed inter nally armed and externally armed Here the dash and number sequences correspond to the settings in the tables on pages 84 and 85 Using the C and gt buttons you can select the required entry position cursor _ is located beneath the selected position You can change the value using the 4 and buttons T External siren is triggered 0 External siren is not triggered Positions that have a cannot be changed If the cursor is located at the far right see the arrow in the figure on the right you can use the 4 and buttons to switch between the three different states disarmed internally armed and ex ternally armed Pressing the OK button a
37. possible open contacts This scan is usually used if you are at home and some windows are open As of course every open window is displayed as a trouble you can hide ignore these currently unimportant trou bles You are in the main menu The LCD displays for example the time date trouble display which is illustrated here on the right 18 06 29 12 Briefly press the Men a A button The troubles menu appears troubles on the LCD Briefly press the OK button The display on the right appears for example contact 1 window in the living room is open livingr w1 Press the unscharf disarm button The text only troubles only appears briefly on the LCD see right Open windows are then ignored troubles door window detector contacts are open Using the 4 and buttons the sensors which exhibit troubles can motion 2 be scanned separately in succession The illustrated example on the garage right shows a trouble with the PIR motion detector in a garage You can use the gt button to display the troubles for the selected sensor sabotage As you can see in the example on the right itis obvious that the PIR motion open detector s casing is open sabotage contact is open An empty battery or a lost sensor contact is also shown at this position sensor message sensor lost lost Remove the trouble if necessary che
38. rarely possible with an alarm system Thus operation during a storm can be dangerous for the alarm system and all connected devices However suitable accessories are available on the market which reduce the risk for the alarm system and other connected devices These include overvoltage pro tectors or similar lightning protection devices Such devices however do not pro vide absolute protection against overvoltages or lightning The accident prevention regulations established by the Employer s Liability Insur ance Association for electrical equipment and facilities must be adhered to in com mercial facilities Responsible supervision must be provided by trained personnel when the product is used in schools training centres do it yourself and self help workshops Using batteries also applicable to rechargeable batteries and button cells Keep batteries out of the reach of children Make sure that the polarity is correct when inserting the batteries Do not leave batteries lying around as they could be swallowed by children or pets In such case seek immediate medical care Leaking or damaged batteries may cause acid burns if they come into contact with skin Therefore please make sure you use Suitable protective gloves Make sure that batteries are not short circuited or thrown into a fire They might explode Never take batteries apart Conventional batteries must not be recharged They might explode If the device
39. station RS To register the sensors the alarm base station must first be set to receive radio signals Carry out the following steps Description of procedure You must be on the main level The LCD should appear as on the right for example with the time and the date Briefly press the Mend a A button on the operating unit of the FAZ 3000 2 alarm base station Use the 4 and buttons to select the sensors menu Confirm by briefly pressing the OK button Press the OK button again Here X is the number of sensors that have already been registered plus one if no sensor has been registered yet then X 1 Display on the LCD disarm 16 30 14 12 troubles sensors sensors add sensor x clear RS Now the FAZ 3000 2 alarm base station is ready to receive the registration of a sensor FAZ 3000 TF 2 door window detector FAZ 3000 PIR 2 PIR motion detector or FAZ 3000 RM smoke detector Before other devices can be registered for example a FAZ 3000 FB 2 remote control a FAZ 3000 AW 3 alarm dialler etc the gt button should first be pressed until the respective device type appears on the alarm base station s LCD See the displays on the right There are six different device types e sensor FAZ 3000 TF 2 door window detector FAZ 3000 PIR 2 PIR motion detecto
40. the date and time b Setting the house code 45 c Registering the sensors 46 1 General notes ue 46 2 Preparing the alarm base station c ccccceeeeeeeeeeeeeees 47 3 Registering the FAZ 3000 TF 2 door window detector 48 4 Registering the FAZ 3000 PIR 2 PIR motion detector 50 5 Registering the remote control c cceecceeeeeeeeeeeeeeeeeeceaeeeeeaeeeeeeeteaeeseeaeeseeeeees 52 12 Function test for the complete Set ccccssecessseeeeseeeeeeeeeeseeeeeeeeeeeeeeesaeeseseeeeeeenes 54 a Testing the remote CONntrol ccccccececeeeeeseeeeeeeeeeceneeeseaeeseaeeseaeeseaaeeseaeesseaeeteneeess 55 b Testing the SenSONs 2 c naw eae aa a ee a ad 56 NBO POM a a A E cade cusccesnzeasaacoceveucssacutecsczas vat ET TE 58 14 Other functions of the alarm base Station cece ecseeenseeeeeeeeseeseeneeeeeeeneneees 59 Troubles nisin ea a eel ot at ee len aren eee ng 59 1 Scanning troubles without scanning possible open contacts cee 60 2 Scanning troubles amp open contacts that prevent internally armed arming 61 3 Scanning troubles amp open contacts that prevent externally armed arming 62 B Events ihon awa sit a ale il OA ei unease we 63 GC SONSOFS weit csi eb ire eA leit bs AL a eh Sd tale etd 64 Tz AdG SENSOMS nrd itz antenna tani tannin A 64 23 Delete SENSONS aksinten ied natty ence A E aE ivi levgeaediecd
41. troubles al dialer al dialer trigger al dialer remote remote off remote 3 ringtone al dialer remote disarm 18 10 23 02 7 Entering a service number SN for connecting to an emergency call centre In this menu a service number SN can be set for connecting the FAZ 3000 2 alarm base station to an emergency call centre EJ For this a contract with the respective emergency call centre is required After com pleting the contract a service number is assigned by the emergency control centre Please also note that depending on which version of the alarm base station you have this menu item may not be available To enter the service number proceed as follows EJ You must be on the main level The LCD should appear as on the right for example with the time and the date Briefly press the Men a A button on the control unit of the FAZ 3000 Z alarm base station Select the al dialler menu using the 4 and buttons See the figure on the right Confirm your selection by briefly pressing the OK button Select the LNR menu using the 4 and buttons See the figure on the right Confirm your selection by briefly pressing the OK button A cursor _ appears on the lower display line Now enter the desired service number SN using the number buttons 0 to 9 on the alar
42. 000 SI 2 wireless siren interface a FAZ 3000 SE 2 wireless activation switch a FAZ 3000 AW 3 wireless alarm dialler or a FAZ 3000 PC 2 wireless PC interface you should select the respective sensor type using the gt button see page 47 Insert the batteries into the sensor The alarm base station should now recognise the new sensor first enter the house code with the FAZ 3000 FB 2 remote control then press a button on the remote control Enter a name for the sensor Set the attributes for the sensor depends on the type of sensor Return to the main level of the alarm base station press the C button three times b Replacing the batteries of a sensor device Set the alarm base station to the service mode see page 71 Open the sensor s casing Replace the batteries Close the sensor s casing Exit the service mode see page 71 c Replacing the alarm base station s batteries Battery appears on the top line of the alarm base station s LCD when its batteries are empty Set the alarm base station to the service mode see page 71 Open the alarm base station s casing Replace the batteries Close the alarm base station s casing Exit the service mode see page 71 112 d Changing the FAZ 3000 FB 2 remote control s code Delete the remote control from the alarm base station see page 67 Keep the ext scharf external arm button on the remote control pressed f
43. 3000 2 wireless alarm base station Alarm base station Power supply Assembly material User manual e FAZ 3000 FB 2 wireless remote control Remote control User manual e FAZ 3000 TF 2 wireless door window detector Door window detector Magnet contact Assembly material User manual e FAZ 3000 PIR 2 wireless PIR motion detector PIR motion detector with attached bracket Assembly material User manual 3 Explanation of icons The icon with a lightning flash in a triangle is used to alert you to potential personal injury hazards such as electric shock The icon with an exclamation mark in a triangle points to particular dangers asso ciated with the handling function or operation of the product The hand icon indicates special tips and operational notes 7 ABCDE Inthis user manualthis fontis used for the alarm system s built troubles in LCD both for textual messages and for the schematic display see the example on the right 4 Safety instructions The product s guarantee becomes invalid if the product is damaged as a result of the failure to observe these operating instructions We do not assume any liability for any resulting damages We do not assume liability for damage to property or personal injury caused by improper use or failure to observe the safety instructions In such cases the product s guarantee becomes invalid Dear customer the fo
44. Battery operation 3 x AAA batteries additional 3 x LR44 button cells if glass break sensor is con nected Sabotage contact e Test function e Dimensions 53mm x 163mm x 24mm W x H x D d FAZ 3000 PIR 2 wireless PIR motion detector Detects heat motion for example movement of a person or an animal in front of a static background of a different tempera ture and signals this as an alarm Adjustable sensor characteristics main sensor range of up to approx 12m detection angle 90 creep zone protection range of up to 4m detection angle approx 43 Creep zone protection e May be installed on walls or ceilings e Sensitivity setting via alarm base station Battery operation 3 x AA batteries Sabotage contact e Test function Dimensions 55mm x 132mm diameter x H 14 Figure 3 Figure 4 e FAZ 3000 RM wireless smoke detector Identical in construction to the RM 100 2 BiDi S smoke detector f Monitors rooms for smoke emission Adjustable sensitivity s Integrated siren for acoustic alarm _ Alarm is set off even when the alarm system is not armed Figure 5 Test function Battery operation 3 x AA batteries Dimensions 125mm x 45mm diameter x H f FAZ 3000 SI 2 wireless siren control Connection of a siren with without flash Sabotage contact for the device itself and for external siren flash Battery operation 4 x type C batteries 4 x AA batter
45. Exit the menu by pressing the C button twice This returns you to the normal display mode main level disarm 20 17 08 02 troubles setup setup set time setup code setup code code setup code code setup 123 code code setup 0000 setup code setup disarm 20 27 08 02 75 5 Programming an access code for internally armed To prevent the alarm system from being switched to internally armed or from internally armed to disarmed by unauthorised persons an access code can be programmed for the state change This access code is only valid for the buttons on the base station itself not for a remote control and is requested after a button is pressed The state is only changed after you have entered the correct code If switching back and forth takes place within a few seconds the code is not requested again Make a note of the code and keep it in a safe place int arm code RS You can deactivate the access code by entering 0000 as the code The access code for internally armed is programmed as follows You must be on the main level The LCD should appear as on the right for example with the time and the date Briefly press the Menu a A button on the control unit of the FAZ 3000 Z alarm base station Use the 4 and buttons to select the set
46. FAZ 3000 wireless alarm system are also well equipped with narrow band receivers and a large range What this means for you On the basis of the security considerations described above the FAZ 3000 wireless alarm system is suitable for use in private homes in self contained apartments as well as in single family houses Actuarially we are talking here about small risks The FAZ 3000 wireless alarm system is not suitable for the kind of mid sized and higher risks that arise in commercial protection for example No liability is assumed by the manufacturer if individual components fail or the complete system fails The manufacturer reserves the right to make technical changes 106 16 Information on the range Ranges and interference The components of the FAZ 3000 wireless alarm system work in the 868 MHz range which is also used by other radio services Therefore devices that operate on the same or neighbour ing frequencies may restrict both its operation and its range The specified range of up to 300m is the free field range which means the range with visual contact between the transmitter and receiver In practice however walls ceilings garages neighbouring buildings and so on between the transmitter and the receiver may affect and reduce the range accordingly Other causes of reduced ranges All types of high frequency interference Any buildings or vegetation Conductive metal parts that are lo
47. IR motion detector s response sensitivity can also be adjusted See pages 69 70 e Carry out this test on all the installed PIR motion detectors Toend the run test function and return to the main level normal operation press the C button twice 57 13 Operation Please observe the following information during your daily use of the alarm system If you use the remote control to switch between the disarmed internally armed and ex ternally armed states then the state changes immediately after you have pressed the respec tive button on the remote control When you use the button on the alarm base station to arm the system to internally armed this also occurs immediately after you have pressed the button When you use the button on the alarm base station to arm the system to externally armed there is a delay of 30 seconds adjustable which allows you to leave your house without having to rush The LCD initially shows ext arming The alarm base station emits a short signal tone after 30 seconds adjustable and switches to externally armed The LEDs go out one minute after arming and the LCD just shows the time and the date and not ext arm for instance After arming it can take a few seconds until for example an open contact is signalled as an alarm After arming the alarm base station and the sensors must first exchange information which can take a
48. J Using a flat screwdriver carefully push the 2 gt own 12 15 1 0 FaZ 23000 catches approx 1 millimetre inwards until the half YT BE ge shells separate see arrow in the figure on the Prt e ge ge right EE 2 E First press one catch inwards and pull the casing Es gee u approx 2 3 millimetres apart at this location Then a press the other catch inwards the casing now opens Figure 12 Do not straighten any of the components or additional PCBs in the alarm base station just so that it looks better Depending on the type of wall drill a hole and insert a dowel Mark the position for the drill hole using a ballpoint pen refill for example Then remove the alarm base station from the wall drill the hole 6mm and insert a dowel Afterwards hang the alarm base station on the 2 upper screws again Please note Do not tighten the third screw yet as the cabling must be carried out first Otherwise the cables cannot be fed into the alarm base station from the lower opening 24 3 Alarm base station cabling All the cable connections to the alarm base station are made from the back through the square opening see figure 13 RS When connecting the cables proceed according to the following sequence a Connect the wired alarm lines and the sabotage line b Connect the DCF receiver not supplied must be ordered separately c Connect the power supply cable caution do not connect the power supply to the supply
49. See figure Q 22 This also prevents it from being easily removed from the wall sabotage protection orn P Be careful not to damage any power supply lines _ KL1 KL2 gas or water pipes as this could pose a life threat s d f EAI enin anger g g pezi ee ai Do not insert the batteries yet The casing should remain open at first A Airs a Ifyou use the supplied magnet attach it using the enclosed double sided tape please note the recommended distances see figure 19 on page 29 Alternatively you can use 2 screws to attach the magnet Remove the magnet s casing using a flat screwdriver and screw in suitable screws Afterwards replace the casing Figure 23 31 The detection lens of the FAZ 3000 PIR 2 c Installing the FAZ 3000 PIR 2 PIR motion detector One FAZ 3000 PIR 2 passive PIR motion detector is included in the set Additional detectors may be purchased separately 1 Installation notes passive PIR motion detector has 4 detection levels with 9 upper 8 middle and 5 lower segments as well as 2 additional creep zone segments The main sensor at the front can attain a range of up to 12m at a detection angle of 90 Please be aware that the detection area is determined by the installation height of the motion dete
50. age 230V 50HZ also available there IS In order to reduce the volume of the internal alarm siren a little for example for the duration of the installation or when carrying out tests the sound outlet of the alarm inside on the alarm base station s circuit board the large round component with the opening in the middle can be covered with a strip of insulating tape for example Stick several strips over each other in order to further reduce the volume See the figure on the right Remove the strips again ifthe alarm base station is to be used in normal operation 42 Figure 31 a Setting the date and time No additional DCR receiver is supplied with the alarm base station or the set must be ordered separately Enter the date and time manually Please note You can return to the last menu or the previous selection using the C button top right of the large keypad Description of procedure You must be on the main level The LCD must resemble the one shown on the right for example Briefly press the Ment a A button on the operating unit of the FAZ 3000 2 alarm base station Use the 4 and buttons to select the setup menu Press the OK button Press the OK button again The hour display is underlined as shown in the figure on the right Set the hours using the 4 and buttons Keeping the 4 or button pressed for a few seconds act
51. alarm Insert 8 AA batteries in the battery compartment for the emergency power supply observing the correct polarity observe plus and minus The polarity can be seen in each battery compartment and there is a small inscription on the circuit board also see figure 18 RS To ensure safe operation rechargeable batteries should not be used As a result of their lower capacity and the lower voltage rechargeable battery 1 2V battery 1 5V a bridging time that is too short may occur in the event of a power outage For safety reasons you should regularly exchange the entire set of batteries 8 for new ones at least once a year Only use high quality alkaline batteries The old batteries from the alarm base station can be used up in clocks torches or radios for example Figure 18 Carefully close the casing Both catches must audibly click in clicking sound so that the sabotage contact is correctly activated 27 5 Initial operation of the alarm base station e Press and hold the 8 tuv button then connect the power supply to a socket 230V 50Hz Then release the 8 tuv button RS This procedure resets the alarm base station s internal memory all sensors and peripheral devices are deleted The alarm base station is then in a defined initial state If at a later poin
52. alarm systems can be replaced with the modern system All sensors except the smoke detectors the peripheral devices and the alarm base station itself are equipped with an integrated sabotage contact which immediately sets off the alarm when the casing is opened without authorisation The sensors are battery operated Due to the particularly low current switching design the battery life of the sensors is up to 3 years The alarm base station itself is operated using the supplied power supply To guarantee op eration during a power outage there is also an integrated emergency power supply 8 AA batteries To increase the accuracy of the alarm base station s integrated clock an external DCF receiver is also available not supplied b 868 MHz wireless technology The transmission of all the alarm and status signals from the sensors and the exchange of data with the peripheral devices takes place over an exceptionally secure bi directional radio connection that operates in the 868 MHz frequency band RS Bi directional means that the radio connection between the sensors and base station operates in both directions Unlike other systems this means that the sensor signals the alarm to the base station and the sensor then receives a form of acknowledg ment from the base station so that it knows that its alarm signal has arrived If the sensor does not receive a return signal for example in the case of short term radio inter
53. amming and operational stages that have already been described and that are sufficient for the simple operation of the alarm system the FAZ 3000 wireless alarm system has many other functions which you will come to appreciate during your daily use of the system These functions are described in the following section a Troubles The alarm base station displays any system troubles Troubles prevent the system from being armed and can be caused by the following Before attempting to arm the system you forgot to shut a window or a door also with open bolt switching contact so that one or several contacts are open The alarm base station s LCD displays cont open A sabotage contact is open for example the casing of one of the sensors is open The LCD displays trouble and the St rung trouble LED lights up The battery of one of the sensors or the alarm base station is empty or no batteries have been inserted The LCD displays battery and the Batterie battery LED lights up The wireless contact with the sensor has been lost and the sensor has not sent any signals for over a period of 90 minutes 1 5 hours The LCD displays trouble and the St rung trouble LED lights up RS There can be a variety of different troubles as you can see Therefore in order to get more information you can scan the troubles on the alarm base station 59 1 Scanning troubles without scanning
54. another remote control proceed as described above Once the remote control or all other available sensors has been reg istered the alarm base station s registration mode can be exited by pressing the C button three times This returns you to the normal display mode main level rem con 2 clear disarm 16 54 14 12 53 12 Function test for the complete set After installation and mounting is completed and you have registered the sensors with the alarm base station the complete set or a single alarm base station with separately purchased sensors and so on is ready for use with its basic functions In order to test the operational reliability whether the sensors work properly and activate in the event of an alarm and to familiarise yourself with the alarm base station you should carry out the function test that is described below IS The FAZ 3000 wireless alarm system carries out an automatic self check every 10 minutes In addition each sensor and each peripheral device for example door window detector establishes a wireless connection with the alarm base station at 10 minute intervals and informs the alarm base station of its status The base station confirms the receipt of the status signal with the sensor In this way the wireless connection is tested in both directions which guarantees a particularly secure transmission The alarm base station is also notified of the sensor
55. ansmits the alarm via the PC interface and or the alarm dialler without the intruder noticing the alarm If transmission of the alarm is not possible the internal and external sirens are activated after wards according to how they have been set EJ Please note You can find the silent alarm on off setting in the PC interface s settings and in the alarm dialler s settings Here exactly the same setting applies This means If you switch the PC interface s silent alarm on it is also au tomatically activated on the alarm dialler also see page 92 To set the silent alarm function proceed as follows You must be on the main level The LCD should appear as on the right for example with the time and the date Briefly press the Men a A button on the control unit of the FAZ 3000 Z alarm base station Use the 4 and buttons to select the PC interf menu PC interface Confirm your selection by briefly pressing the OK button Use the 4 and buttons to select the silent al menu silent alarm Confirm your selection by briefly pressing the OK button The state that is currently set appears on the LCD factory set to no Use the 4 and Y buttons to select the setting you require Silent alarm is switched on Silent alarm is switched off yes no Pressing the OK button applies the setting
56. aracter you entered by mistake Once you have entered the name you require press the OK button If a smoke detector is registered then registration is now complete and sensor x the alarm base station is ready to register the next sensor If there are clear no further sensors to register you can exit the registration procedure by pressing the C button three times The alarm base station then disarm returns to the main level in the normal operating mode See the figure 10 23 05 02 on the right e The display illustrated here on the right appears on the LCD for a door close N window detector or PIR motion detector intern N You can use the gt button to set the sensor as an internal sensor intern Y or external sensor intern N jntern N External sensor alarm is set off for internally armed and externally armed jntern Y Internal sensor alarm is only set off for externally armed For more detailed information see page 46 By pressing the 4 button you can access the closure group settings close the N on the upper line is underlined Use the 4 and buttons to change intern the entry line zz 65 Using the gt button you can select whether the sensor belongs to the closure group Y or not N You can find further information on this on page 20 or page 46 If a door window
57. arm Likewise simultaneously pressing the two ext external arm and int internal arm buttons does not trigger an attack alarm You can stop the alarm in the usual way simply press the unscharf disarm button briefly on the alarm base station or the remote control 113 21 Declaration of conformity DOC We Conrad Electronic Klaus Conrad StraRe 1 92240 Hirschau Germany hereby declare that this product complies with the fundamental requirements and other relevant regulations of direc tive 1999 5 EC IS You can find the declaration of conformity for this product at www conrad com 114 115
58. ase station has two arming options Internally armed and externally armed The internally armed function provides protection of the exterior of a building such as when you are in your house at night for instance Only sensors that are involved in protecting the exterior of the building are allowed to respond These include door window detectors in an apartmentor PIR motion detectors that are mounted externally PIR motion detectors located inside an apartment are not allowed to respond and must therefore be set to Intern Y The externally armed function is used to monitor an unoccupied building such as a house when no one is at home for instance The exterior shell of the building is monitored using door window detectors for example as well as the indoor areas provided that internal PIR motion detectors are installed All the sensors trigger the alarm irrespective of how they are assigned Closure group Allsensors that directly protect outside doors for example door window detectors or PIR motion detectors should be assigned to the closure group RS See page 20 of this user manual for an explanation of the closure group function Sensitivity only for PIR motion detectors You can set the response sensitivity of the PIR motion detector RS Sensitivity levels from 1 to 4 are available 4 is the highest sensitivity The factory setting is 3 46 2 Preparing the alarm base
59. button Press the C button twice in succession Afterwards you return to the normal display mode main level 44 16 14 28 12 00 16 14 28 12 03 16 14 28 12 205 16 14 28 12 03 setup set time setup disarm 16 28 14 12 b Setting the house code A so called house code can be set in order to ensure that the alarm systems do not interfere with each other when several alarm systems are used in the wireless range The house code can be set from 1 to 15 15 possible options EJ All you need to do is set two different house codes Description of procedure You must be on the main level The LCD should appear as on the right for example with the time and the date Briefly press the Ment a A button on the operating unit of the FAZ 3000 2 alarm base station Use the 4 and buttons to select the setup menu Confirm by briefly pressing the OK button Select the housecode menu using the 4 and buttons lower line of the LCD Press the OK button The currently selected house code appears on the LCD factory setting 1 Select the desired house code using the 4 and buttons A setting from 1 15 is possible To confirm the selected house code briefly press the OK button Press the C button twice in succession A
60. cated near the devices or within or near their transmission path for example radiators metallised insulation glass windows reinforced concrete ceilings and so on as well as metallised walls in prefabricated houses Influence on the radiation pattern of antennas due to the distance from the transmitter or receiver to conductive surfaces or objects also to human bodies or the ground Broadband interference in urban areas that reduces the signal to noise ratio the signal is no longer recognised due to this noise Interference radiation resulting from insufficiently shielded electronic devices for example operating computers or similar IS The actual attainable distance between the transmitter and the receiver in normal operation therefore greatly depends on the installation location and the surroundings As a rule when mounted in a family home for example all the components should work properly and there should be no radio reception problems 107 17 Disposal a General information When the product is no longer usable dispose of it in accordance with the applicable statutory regulations b Battery rechargeable battery disposal As the consumer you are legally obliged to return all your used batteries and rechargeable batteries Do not dispose of your used batteries via the household rubbish Batteries rechargeable batteries containing harmful substances are marked with the NF following icons which aler
61. ce e g opening the casing and replacing the batteries This function is used for replacing the batteries of the sensor device or alarm base station or for modifying the wiring of the external NO NC contacts connected to a door window detector for example During the service neither the alarm nor the sabotage alarm are triggered for example opening the casing of a sensor or device or the alarm base station immediately sets off an alarm You must be on the main level The LCD should appear as on the right for example with the time and the date Briefly press the Men a A button on the operating unit of the FAZ 3000 2 alarm base station Use the 4 and buttons to select the service menu See the figure on the right Confirm your selection by briefly pressing the OK button The first sensor that was registered with the alarm base station is displayed Use the 4 and Y buttons to select the sensor that you wish to open in order to replace the batteries for instance You can select other devices signal transmitter activation switch alarm dialler PC interface and alarm base station using the gt button Confirm your selection by briefly pressing the OK button You can now open the casing of the selected sensor without setting off a sabotage alarm in order to replace the batteries for example No data is lost and the sensor or the device does not need to be
62. ck the sensor insert new bat teries etc Return to the alarm base station and keep pressing the C button until disarm you return to the alarm base station s main menu 18 10 29 12 If disarm appears on the LCD then the trouble has been removed Otherwise check again if and which other troubles are present If there are no troubles no troubles appears when you press no the OK button in the troubles menu see above troubles 60 2 Scanning troubles amp open contacts that prevent internally armed arming You can use this scanning option to determine what it was that prevented the internally armed arming As you can see in section 13 page 58 it should be possible to arm the system to internally armed the first time you press the intern scharf internal arm button on the remote control or the alarm base station If you find that you need to press the button a second time you can now determine what the cause You are in the main menu and the LCD appears as shown on the right for example Briefly press the Men a A button The troubles menu is displayed on the LCD Briefly press the OK button The display on the right appears for example window in the living room is open Press the intern scharf internal arm button preventions int arm internal arm prevention appears briefly on the LCD Using the 4 and bu
63. command menu using the 4 and Y buttons Confirm the selection using the OK button e The LCD s display should now switch to disarm and the time and disarm date are displayed on the lower line 0 01 1 01 The colon between the hours and minutes blinks The alarm base station is now ready 28 b Installing the FAZ 3000 TF 2 door window detector One door window detector is supplied in the set Additional detectors may be pur chased separately 1 Installation notes e Magnetic sensors reed switch are located inside the FAZ 3000 TF 2 door window detec tor on the left and on the right side This means that you can mount the supplied magnet either on the left or on the right side A two sided installation of 2 magnets one on the left and one on the right of the door window detector is not possible Make absolutely sure that the lower edge of the magnetis 20mm away from the lower edge of the door window detector Mounting the magnet higher or lower A reduces the magnetic range the mag net must be installed closer to the door window detector e The horizontal distance between the max 25 mm max25 mm magnet and the door window detec Par z tor should not exceed 25mm The ideal Pa distance is approx 10 15mm Tip Before using screws to mount the device you should first check that it Y is working properly so as to avoid drilling any unattractive ho
64. ctor as well as the adjustment of the lens opening Therefore the diagram on the right is only 0 12 3 4 5 6 7 8 9 10 m intended as an example for the lens optics When mounted in a bracket the sensor can be turned approx 45 which makes it easier to adjust the detection area later on 0 1 2 3 4 5 6 7 P S40 um Figures 24 amp 25 For additional security the PIR motion detector is equipped with so called creep protection so that an intruder cannot creep under the detection area of the main lens The creep zone protection comprises an additional lens on the underside of the PIR motion detector which is directed downwards This mini dome lens with 17 segments covers an area of approx 3 75m x 3 75m when the PIR motion detector is installed at a height of 2m A larger area can of course be covered when the PIR motion detector is installed higher up In order to avoid household pets from setting off a false alarm keep them away from protected areas when possible If this is not possible try to change the detection area by adjusting the height of the circuit board in the PIR motion detector If necessary cover the creep zone protection or individual parts of the lenses To do this you can use non transparent insulating tape Bear in mind that household pets can also jump up onto cupboards or chairs for example and can thus enter the detection area and activate the motion detector Select a sui
65. e 21 57 08 02 Briefly press the Men a A button on the control unit of the FAZ 3000 troubles Z alarm base station e Use the 4 and buttons to select the ext siren menu external ext siren siren See the figure on the right Confirm your selection by briefly pressing the OK button ext siren trigger e Use the 4 and buttons to select the dur flash menu duration ext siren for the flash dur flash Confirm your selection by briefly pressing the OK button dur flash The duration that is currently set appears on the LCD factory set to 60 20 min seconds Use the 4 and buttons to select the required duration You can set dur flash this to a value between 1 and 100 minutes in increments of 1 minute 60 min To make a quick setting keep the 4 or Y button pressed for a few seconds Pressing the OK button applies the setting ext Sirene dur flash Exit the menu by pressing the C button twice This returns you to the disarm normal display mode main level 22 10 08 02 88 i Settings for the FAZ 3000 AW 3 alarm dialler The following settings can be carried out for operation of the alarm dialler Conditions for setting off the alarm e Silent alarm on off Enter telephone number 1 2 and 3 Enter dialout number Enter the alarm
66. e alarm is effected via the alarm dialler set to 1 RS Observe these three tables when you change the settings See the next page 90 You can change the conditions for setting off the alarm as follows You must be on the main level The LCD should appear as on the right for example with the time and the date Briefly press the Men a A button on the control unit of the FAZ 3000 Z alarm base station Use the 4 and buttons to select the al dialler menu alarm dialler Confirm your selection by briefly pressing the OK button Confirm your selection by briefly pressing the OK button Please note the position of the cursor _ If the cursor is located pre cisely at this position at the far right you can use the 4 and buttons to switch between the three different states disarmed inter nally armed and externally armed Here the dash and number sequences correspond to the settings in the tables on pages 89 and 90 Using the C and gt buttons you can select the required entry position cursor _ is located beneath the selected position You can change the value using the 4 and buttons T The alarm is triggered via the alarm dialler 0 No alarm is triggered via the alarm dialler Positions that have a cannot be changed If the cursor is located at the far right see the arrow i
67. e containing the factory settings for the disarmed state Disarmed state Alarm when Alarm when Alarm upon Alarm upon Alarm upon int armed ext armed smoke sabotage attack detection e Itis not possible to trigger the PC interface for internally armed and externally armed because of the current disarmed state each set to f a smoke detector is triggered no alarm is effected via the PC interface set to 0 Ifa sabotage contact is triggered no alarm is effected via the PC interface set to 0 In the event of an attack no alarm is effected via the PC interface set to 0 98 Table containing the factory settings for the internally armed state Internally armed state Alarm when Alarm when Alarm upon Alarm upon Alarm upon int armed ext armed smoke sabotage attack detection Inthe event of an alarm the PC interface is not triggered for internally armed set to 0 The state is internally armed therefore triggering of the PC interface for externally armed is not possible set to If a smoke detector is triggered no alarm is effected via the PC interface set to 0 f a sabotage contact is triggered no alarm is effected via the PC interface set to 0 In the event of an attack no alarm is effected via the PC interface set to 0 Table containing the factory settings
68. e entered once the batteries have been inserted 9 digit key sequence which is entered using 3 buttons Thus 3 19683 different codes are possible The alarm base station analyses every remote control command that it receives the alarm base station only responds if the code saved in the alarm base station from a registered remote control is the same as the received code Proceed as follows e Think of a code and make a note of it on a sheet of paper for example the code may only include the numbers 1 2 and 4 for example 142142142 You will need to enter the code again in the future when you replace the batteries IS Please note Four remote controls can be registered with the base station which must be coded differently Additional remote controls can be operated by programming the same code as an already registered remote control Use a coin to open the cover of the battery compartment on the back of the remote control Turn the cover clockwise a little in the direction of the arrow open until it can be removed Insert a CR2016 button cell observing the correct polarity The side a marked with plus has to point towards you figure 29 Replace the cover and secure it by turning it anticlockwise in the direction of the arrow close tC The LED on the front blinks for approx 20 seconds which sig nals that it is ready to receive the code If the code
69. e value of the total resistance must be clearly larger or smaller than this value so that the alarm can be set off properly In isolated instances a different terminating resistor may be required The maximum attainable wiring length of the alarm loop is greatly dependent upon the cable used and the transmission resistance of the sensors Under ideal circumstances 100m or more is possible Please note NC contacts NO contacts NC and NO contacts 2 3 S A O a 3 Figure 14 2 3 2 O g a Figure 15 S a O gt 3 Figure 16 A short circuit occurring on the sabotage line connection of both KL2 contacts always triggers the alarm regardless ofthe disarmed internally armed and externally armed setting 4 Completing the installation After all the cables have been led through the opening and connected as shown in the example in figures 17 and 18 screw in the third screw through the opening Attach the base station by screwing the third screw into the wall See figure 17 below KL1 KL2 KL3 KL4 KL5 KL6 26 SEO VODSSIDVUSS A N om a e SI2 1 BU2 Figure 17 RS Please note The resistors found in the connection clamps KL2 to KL6 each 10kOhm must be connected to the end of the alarm line See page 26 upper right Only this way can the system recognise when the cables are cut and register this as an
70. ebesbes 67 3 Modify a sensor name or assign a sensor name retrospectively 68 4 Modifying checking Sensor attributes 2 2 eee eeceeeeeeeeeeeeeeeeeeseeeeeeeeeeteeeeeeaeeees 69 d Service for example opening the casing and replacing the batteries 71 e Configuration setup menu iteM ceeeeeeeeeeeeeeeceneeeeeaeeeeeeeeseeeeseeeeseeeseeeeeteaees 72 T Setting the time ANG date cic scccecccevssescscencssccesenccacteoesotsceteabcaveerscanteavsensesteateaste 72 2 DCF setup reception CheCK naiiai aa aa eaae ad aa a ea E 73 3 Setting the exit delay for externally armed 74 4 Programming an access code for the settings 75 5 Programming an access code for internally armed 76 6 Programming an access code for externally armed ccceeeeeeeeeeeeeeeeee 77 f RUTES Gajai en ead eh eat el een ede ie 78 g Settings for the internal Sire oo eee aieiaa aad aaae 78 1 Conditions for setting off the alarm changing the settings c eeeee 78 2 Setting the duration for the internal siren cccccceeeceeeeeeeeeeeeeeeeeteteeeteeeeeeeee 81 3 Setting the duration of the signal tone for when the intern scharf internal arm button is pressed cccceceeeeceeceeeeeeeeeeeeeeeceeeeeseaeeeseaeeesseeeseaeeess 82 4 Setting the duration of the signal tone for when the extern scharf external arm button is pressed eeeceeeseeceee
71. eeeeeeeeeeeeeeeeeeseaeeseeaeeeeeeeesseeess 83 h Settings for the FAZ 3000 SI 2 external siren cee 84 1 Conditions for setting off the alarm changing the settings 84 2 Setting the duration for the external siren ee 87 3 Setting the duration for the external flash eccececeeeeeeeteeeeceeeeeeeeeeteeeteeee 88 i Settings for the FAZ 3000 AW 3 alarm dialler c ccecceeeeeeeeeeeeeeeeeeeteeeeeeeees 89 1 Conditions for setting off the alarm changing the settings 89 2 Sil ntalarm On off seevsvececoute cance ea ainaani cai deo eedetons ceases 92 3 Entering the telephone numbers cceccceeeseeceeeeeeeeeeeeeeeeteaeeeeeaeeteneeeteaeeeeaee 93 4o Dialout numbers snini ana a a anda cccbne be rae ai 94 5 Enter the alarm dialler s access code for remote control 0008 95 6 Enabling of remote control configuration of automatic call acceptance 96 7 Entering a service number SN for connecting to an emergency call centre 97 j FAZ 3000 PC 2 PC interface settings cceeeeeeereteeeeees 1 Conditions for setting off the alarm changing the settings 2 Silentalarm ON off eisi ha aa aade e aE iaaii k The wired alarm lines ccccceeceeeeeeeeeeneeeeeeeeeeeteeeeteees 102 1 Enter or modify the names of the wired alarm lines 102 2 Set or modify the attributes of the wired alarm lines
72. elected position You can change the value using the 4 and buttons T Internal siren is triggered 0 Internal siren is not triggered Positions that have a cannot be changed If the cursor is located at the far right see the arrow in the figure on the right then you can switch between the three different states disarmed internally armed and externally armed using the 4 and buttons Pressing the OK button applies the new settings Exit the menu by pressing the C button twice This returns you to the normal display mode main level 80 disarm 20 17 08 02 troubles int siren int siren trigger disarm 111_ int arm 1 111_ ext arm alata ext arm 1111 ext arm 1101 ext arm 1101_ t int siren trigger disarm 20 27 08 02 2 Setting the duration for the internal siren The duration for the internal siren is factory set to 60 seconds however you can adjust this time to a value between 10 and 300 seconds Caution The maximum duration for an acoustic alarm that sounds outside is restricted by law to 3 minutes an external flash can signal for longer This may vary at health resorts for example Therefore as a precaution check this out with your local council The duration for indoor areas is not normally affected by t
73. ference then it repeats its alarm signal until it receives an answer from the base station This considerably increases the security of the radio transmission compared with simple wireless systems 17 The use of high quality sensitive receivers results in a wireless range of up to 300m in free field RS Here the term free field stands for the ideal case in which there is direct visual contact between the transmitter and receiver as in a meadow for example In practice however walls windows doors and concrete ceilings or other objects between the sensor and the base station may reduce the range Weak batteries also reduce the range You can find further information in section 16 Information on the range page 107 The radio transmission takes place in the 868 MHz frequency band 868 0 to 868 6 MHz Thanks to the legal restriction of transmission duration in this band to a maximum 36 seconds per hour 1 duty cycle 1 hour 3600 seconds the danger of interference from other radio services is minimised RS Unlike the 433 MHz frequency band which most conventional wireless alarm sys tems use no permanent transmitters can emerge in the 868 MHz frequency band for example wireless headphones Such devices can permanently disrupt another radio transmission which makes it impossible to transmit an alarm signal c disarmed int armed and ext armed operating modes e Disarmed opera
74. fterwards you return to the normal display mode main level This feature makes it possible for your neighbour to also use the same alarm system Display on the LCD disarm 16 30 14 12 troubles setup setup set time setup housecode 1 housecode 10 setup housecode setup disarm 16 35 14 12 45 c Registering the sensors 1 General notes All the additional components of the system for example the FAZ 3000 TF 2 door window detectors passive FAZ 3000 PIR 2 PIR motion detectors etc must be registered with the alarm base station As described in section 8 page 21 you should make a plan or layout of the object to be protected for example house or apartment and then mark the sensors on the plan layout The following information is necessary for registration Name This is the name you have entered for the sensor in your layout diagram a maximum of 11 characters can be entered in the alarm base station for the sensor Example Livingr W1 for Living room Window 1 e Internal external sensor RS The response behaviour of each sensor can be determined by assigning the sensor either as an internal one or an external one Intern N External Sensor alarm is set off for internally armed and externally armed Intern Y Internal sensor alarm is only set off for externally armed The alarm b
75. g As you can see in section 13 page 58 it should be possible to arm the system to externally armed the first time you press the extern scharf external arm button on the remote control or the alarm base station If you find that you need to press the button a second time you can now determine what the cause IS You are in the main menu and the LCD appears as shown on the right for example Briefly press the Men a A button The troubles menu is displayed on the LCD Briefly press the OK button The display on the right appears for example window in the living room is open e Press the extern scharf external arm button preventions ext arm external arm prevention appears briefly on the LCD Usingthe 4 and v buttons the sensors which prevent external arming can be scanned individually and in succession In the example figure on the right the door window detector in the living room is the cause Youcanuse the gt button to display the troubles for the selected sensor As you can see in the example on the right the magnet contact is open the window is probably open however the magnet that was stuck on may also have fallen off If necessary remove the trouble for example close the window stick the magnet contact on again and so on Return to the alarm base station and keep pressing the C button until you return to the ala
76. h takes place within a few seconds the code is not requested again Make a note of the code and keep it in a safe place ext arm code RS You can deactivate the access code by entering 0000 as the code The access code for externally armed is programmed as follows You must be on the main level The LCD should appear as on the right for example with the time and the date Briefly press the Men a A button on the control unit of the FAZ 3000 Z alarm base station Use the 4 and buttons to select the setup menu Confirm your selection by briefly pressing the OK button Select the code extern menu using the 4 and buttons code for switching to externally armed Confirm your selection by briefly pressing the OK button You can now use the number buttons to enter any four digit code for example 1234 or 9876 and so on You can use the C button to correct any incorrect entry you have made If you want to switch off the access code no code request for externally armed enter 0000 as the code Pressing the OK button applies the setting Exit the menu by pressing the C button twice This returns you to the normal display mode main level disarm 20 17 08 02 troubles setup setup set time setup code extern code ext
77. he casing This product is not a toy Install the components of the wireless alarm system so that they are out of the reach of children Never connect the device to the supply voltage immediately after it has been brought from a cold room into a warm one The temperature change may cause condensation water to form which may lead to malfunction damage or an electric shock Allow the device to reach room temperature before connecting it to the supply voltage This may take several hours Make sure that the device does not get damp or wet Do not place vases or plants onor close to the product for example Liquids could seep into the interior of the casing and compromise electrical safety There is also a high risk of fire or fatal electric shock In this case immediately disconnect the device from the supply voltage switch off the current to the socket remove the power supply from the socket and do not operate the device again Take it to a skilled technician Do not leave packaging material lying around This may become a dangerous play thing in the hands of children All maintenance work programming or repairs should only be carried out by a skilled technician or professional workshop Thunderstorms can pose a danger to all electrical equipment Overvoltages on the power supply line can damage the device Whereas a television or other device for example can easily be unplugged by removing the power plug from the socket this is
78. he sensor contacts the base station by sending a radio signal The sensor s LED lights up briefly and the base station emits a short signal tone to confirm reception Ifyou want to operate additional NO contacts on KL1 then please insertthree LR44 button cells with the correct polarity into the battery compartment See figure 33 The three button cells must be inserted so that plus points upwards in each case observe the symbol on the circuit board next to the battery compartment RS Please note The KL1 connection for NO contacts is always active irrespective of the disarmed internally armed or exter nally armed setting This is ideal if glass break sensors with NO contacts are used An alarm is set off immediately when a pane of glass is smashed Close the door window detector s casing so that the two locking hooks audibly click in 48 KL1 KL2 Coes TAI D1 ee S Figure 32 KL1 KL2 Figure 33 Return to the alarm base station The LCD s display has changed See the figure on the right
79. his restriction However if an internal alarm signal is very loud and is also clearly audible outside then the legal restriction may apply here too To set the duration proceed as follows You must be on the main level The LCD should appear as on the right disarm for example with the time and the date 21 27 08 02 Briefly press the Men a A button on the control unit of the FAZ 3000 troubles Z alarm base station e Use the 4 and buttons to select the int siren menu internal int siren siren Confirm your selection by briefly pressing the OK button int siren trigger e Select the duration using the 4 and buttons See the figure sake Siran on the right duration Confirm your selection by briefly pressing the OK button duration The duration that is currently set appears on the LCD factory set to 60 60 sec seconds Use the 4 and buttons to select the required duration You can set duration the duration to a value between 10 and 300 seconds in increments of 90 sec 10 seconds To make a quick setting keep the 4 or Y button pressed for a few seconds Pressing the OK button applies the setting int siren duration Exit the menu by pressing the C button twice This returns you to the disarm normal display mode main level 21 33 08 02 81 3
80. ht you can use the 4 and buttons to switch between the three different states disarmed internally armed and ex ternally armed Here the dash and number sequences correspond to the settings in the tables on pages 98 and 99 Using the C and gt buttons you can select the required entry position cursor _ is located beneath the selected position You can change the value using the 4 and buttons T The alarm is triggered via the PC interface 0 The alarm not is triggered via the PC interface Positions that have a cannot be changed If the cursor is located at the far right see the arrow in the figure on the right you can use the 4 and buttons to switch between the three different states disarmed internally armed and ex ternally armed Pressing the OK button applies the new settings Exit the menu by pressing the C button twice This returns you to the normal display mode main level 100 disarm 21 27 25 02 troubles PC interf PC interf trigger disarm 000_ int arm 0 000_ t ext arm 0000_ ext arm 0000 ext arm 0100 ext arm 0100_ t PC interf trigger disarm 21 33 25 02 2 Silent alarm on off In the case of a silent alarm the FAZ 3000 Z alarm base station tr
81. hus the components of the FAZ 3000 wireless alarm system also offer no absolute protection in terms of hundred percent availability although their high quality lays the best foundations for long term operation The FAZ 3000 wireless alarm system uses radio transmission in the 868 MHz range to transmit signals and exchange data between the different components In addition to the simple installation which is one particular advantage you do not need to lay any cables wireless technology offers the advantage that no defective cables contact junc tions near the cables and connection clamps can lead to troubles The disadvantage of wireless technology however is that each radio transmission can be subject to interference regardless of how innovative elaborate and redundant it is Thus the radio transmission between the individual components of the FAZ 3000 wireless alarm system also presents a potential source of error whereby hundred percent availability cannot be guaranteed Unlike basic wireless alarm systems the FAZ 3000 wireless alarm system features bi direc tional transmission This means that it is not just the sensors that can send an alarm signal to the alarm base station the alarm base station can also return confirmation of the receipt of an alarm or other signal for instance Battery empty to the sensors In order to ensure a high level of transmission reliability the components of the
82. iarise yourself with the FAZ 3000 2 alarm base station s controls and displays as well as the operating structure basics by reading the complete user manual a Displays amp controls of the FAZ 3000 2 alarm base station You will find the following displays and controls on the front of the alarm base station s casing Control panel with 6 status LEDs Netz power Displays the availability of the supply voltage St rung trouble Lights up when there are any troubles such as sabotage contact open Batterie battery Lights up when the alarm base station s reserve batteries are running low unscharf disarmed The alarm system is switched to disarmed intern scharf internally armed The alarm system is switched to internally armed extern scharf externally armed The alarm system is switched to externally armed e LCD The LCD has a backlight and two lines each with 11 positions It is used for displaying status signals as well as for simple programming Keypad with number buttons and control buttons for programming The 16 buttons ordered 4x4 are for programming the base station and for querying data The number buttons 2 to 9 are labelled with the letters of the alphabet just like a telephone This is used in each menu for programming sensor names etc for example The 0 button is also a space character Keypad for arming The 3 round but
83. identical to those of the current version of the motion detector The current FAZ 3000 TF 2 door window detector in use when this user manual was issued varies from its predecessor only in the number of batteries required to operate it along with the alternative design of its circuit board RS If you find that the components in the FAZ 3000 wireless alarm system that you obtain look alittle different from those depicted in this user manual please read the user manual enclosed with the respective product when assembling or initially operating the device As already stated any differences are limited to the appearance alternative assembly and possible variations in the technical data for example battery types dimensions and so on 110 19 Technical specifications a FAZ 3000 Z wireless alarm base station Number of wireless components Max 100 sensors and peripheral devices Wired life Siccvitis satedtinecaele ane 4 alarm lines 1 sabotage 10 W difference lines Power supply for external sensors 12V 315mA Internal siren 90 dB 1m Power supply sesse 12V 500mA stabilised Emergency power battery 8X AA alkaline recommended Frequency sch rianan saei nesies 868 35MHz Ranges arsen arira aeia iaaeaie Up to 300m free field Dimensions W x H x D nesses 220mm x 230mm x 50mm b FAZ 3000 FB 2 remote control Security codes ccecceeesseeeeeeeeeeees 19683
84. ies Can also be operated using a power supply Dimensions 123mm x 240mm x 50mm W x H x D Onnao Fars Figure 6 g FAZ 3000 SE 2 wireless activation switch For arming the system via a bolt switching contact or external key switch button Sabotage contact for the device itself and for the external key switch button Option to connect 2 external LEDs status LEDs Battery operation 3 x AAA batteries Dimensions 53mm x 163mm x 24mm W x H x D Onna FAZ SE Figure 7 15 h FAZ 3000 AW 3 wireless alarm dialler In the event of an alarm dials programmable numbers maximum of 3 different numbers each comprising a maximum of 22 digits to alert your own mobile phone friends neighbours and so on for example Indication of the alarm trigger Internal external smoke attack sabo tage Querying the status of the alarm base station via a telephone Remote control of alarm base station Detection of dial tone Programmable dialout number DTMF dialling tone dialling Sabotage contact Battery operation 4 x baby C batteries Can also be operated using a power supply Dimensions 123mm x 240mm x 50mm W x H x D i FAZ 3000 PC 2 wireless PC interface Configuration of the alarm system via a computer current Windows operating system required Remote control of alarm system is possible Alarm triggering via a computer email SMS etc Sabotage contact Battery operation 4 x baby C ba
85. ight figure is the number of already registered sensors plus one in other words the next available memory slot e You select the remote control using the gt button The display shows rem con 1 rem con 1 on the upper line clear e Briefly press any button on the remote control The alarm base station rem con 1 acknowledges reception by emitting a short signal tone and the LCD on S the alarm base station switches to the display for entering the name of the remote control Usethe buttons on the alarm base station to enter the name of the remote rem con 1 control such as the name of the person who is using the remote control Peter_ gt To enter the letters use the 2 9 buttons each of which represents several letters click through as with a mobile phone by repeatedly and quickly pressing the same button gt Numbers and umlauts can also be found on the buttons for instance Use the 0 button to enter a space character Special characters can be entered using the 4 and buttons You can use the Men a A button to switch between lower and upper case gt The cursor automatically jumps to the next position approx one second after the last button was pressed gt You can use the C button to delete a character you entered by mistake Once you have entered the name you require press the OK button 52 e If you wish to register
86. ion s settings can be locked using a 4 digit access code menus are accessed using the Ment a A button so that the settings cannot be changed by any unauthorised person This access code is then requested before access to the menus is granted See the figure on the right Access to the menus is only possible after the correct code has been entered Make a note of the code and keep it in a safe place setting code RS You can deactivate the access code by entering 0000 as the code The access code is programmed as follows You must be on the main level The LCD should appear as on the right for example with the time and the date Briefly press the Men a A button on the control unit of the FAZ 3000 Z alarm base station Use the 4 and buttons to select the setup menu Confirm your selection by briefly pressing the OK button Select the code setup menu using the 4 and buttons code for access to the settings menus Confirm your selection by briefly pressing the OK button You can now use the number buttons to enter any four digit code for example 1234 or 9876 and so on You can use the C button to correct any incorrect entry you have made If you want to switch off the access code no code request before menus are accessed enter 0000 as the code Pressing the OK button applies the setting
87. ion detector this will of course also trigger an alarm and the first function notification of the first PIR motion detector is replaced by the function notification of the other PIR motion detector In this case the presence of a second person can be helpful One person can test the sensors while the other person checks the function messages directly on the alarm base station This makes sense especially when you are trying to align the detection area of the PIR motion detector correctly since the desired detection area can only be set in this way via the alarm base station there is only confirmation thatthe motion detector has activated which however provides no information on the detection area Adjusting the PIR motion detector s detection area e Openthe PIR motion detector s casing by releasing both catches on the left side of the casing see page 34 Loosen both fastening screws on the circuit board see page 35 The circuit board can be moved up and down After each movement the circuit board should be provisionally secured using a screw and the casing should be closed Afterwards pace out the desired detection area it makes sense to ask a second person to help by checking the function notification on the alarm base station Once you have found the right setting for the detection area open the PIR motion detector s casing tighten the two fastening screws of the circuit board and close the casing again The P
88. is functioning and if the alarm base station was notified of the break in livingr w1 the magnetic contact See the figure on the right I 56 If you step across the PIR motion detector s detection area whilst passing between the installation location of the door window detector and the alarm base station this will of course also trigger an alarm and the previous function notification of the door window detector disappears and is replaced by the function notification of the PIR motion detector In this case the presence of a second person can be helpful One person can test the sensors while the other person checks the function messages directly on the alarm base station e Carry out this test for all the installed mounted door window detectors e Finally check the PIR motion detector Move around in the detection area of a PIR motion detector Ifthe PIR motion detector detects you the LED on the inner right of the motion 2 detector under the lens lights up it may not be easily visible and the garage alarm base station emits a short alarm signal this may not be audible depending on how far you are from the alarm base station Finally check the alarm base station s LCD to see whether the sensor is functioning and if the movement in the detection area was recognised RS If whilst passing through the installation location of the PIR motion detector you step across the detection area of another PIR mot
89. itch in conjunction with a bolt switching contact in the door s locking plate or an external key switch FAZ 3000 AW 3 wireless alarm dialler FAZ 3000 PC 2 wireless PC interface e Alarm The FAZ 3000 wireless alarm system allows the alarm to be effected in various ways Internal siren in the FAZ 3000 2 alarm base station In the event of an alarm the alarm base station s integrated siren sound pressure 90dB issues the alarm This may be sufficient for smaller apartments or buildings e External siren flash via FAZ 3000 SI 2 siren control A siren mounted to the exterior of the house and an alarm flash can be operated via the FAZ 3000 SI 2 siren control in order to alert neighbours to the alarm FAZ 3000 AW 3 alarm dialler and FAZ 3000 PC 2 PC interface If you wish to send alarm signals over longer distances you can do so using the FAZ 3000 AW 3 alarm dialler and or the FAZ 3000 PC 2 PC interface e Silent alarm Of course you may wish to only set off a silent alarm so that the intruder is unaware of the alarm In the case of a silent alarm the alarm is not issued by the internal siren of the FAZ 3000 Z or the FAZ 3000 SI 2 siren control but only by the FAZ 3000 AW 3 alarm dialler or the FAZ 3000 PC 2 PC interface For safety reasons if the alarm dialler or the PC interface is unable to transmit the alarm the alarm is subsequent
90. ivates the quick setting Alternatively you can enter the hours using the number buttons 0 9 on the control panel Use the gt button to switch to the minutes setting use the C button to return to the hour setting Adjust the minute display using the 4 and buttons Alternatively you can enter the minutes using the number buttons 0 9 Use the gt button to switch to the date day setting You enter the day using the 4 and Vv buttons again Alternatively you can enter this using the number buttons 0 9 Use the gt button to switch to the month setting Set the month using the 4 and buttons or using the number buttons 0 9 Display on the LCD disarm 0 05 1 01 troubles setup setup set time 0 01 1 01 00 mo 16 01 6 1 01 00 mo 1 01 00 mo 1 01 00 MO 16 28 1 01 00 mo 16 28 14 01 00 mo 16 28 14 01 00 mo 16 28 14 12 00 mo 43 Use the gt button to switch to the year setting Set the year using the 4 and buttons or using the number buttons 0 9 Use the gt button to switch to the weekday setting Set the weekday using the 4 and buttons Alternatively you can set the weekday using the number buttons 1 7 assignment 1 Monday 7 Sunday e To finish confirm your entry using the OK
91. larm system settings code intern Enter security code for internal arming e code extern Enter security code for external arming e house code Enter the house code in order to operate several neighbouring FAZ 3000 wireless alarm systems 1 Setting the time and date You can find a description of how to set the time and date in section 11 a pages 43 and 44 of this user manual 72 2 DCF setup on off reception check Please note This function or the respective DCF setup menu item is only available when a DCF receiver is connected An external FAZ 3000 DCF DCF receiver can be connected to the FAZ 3000 2 alarm base station not supplied but must be ordered separately This allows the FAZ 3000 Z s internal clock and date to be set automatically and accurately Once connected the DCF receiveris automatically recognised see section 9 a page 25 activated and analysed it can take a few minutes for the DCF time date to be set You can switch the DCF receiver on or off via the DCF setup menu You can also check whether a synchronisation has taken place reception check You must be on the main level The LCD should appear as on the right for example with the time and the date Briefly press the Men a A button on the operating unit of the FAZ 3000 2 alarm base station Use the 4 and buttons to select the setup menu
92. les in the 20 mm wrong location j 3 i 20 mm Figure 19 The internal magnet contact the magnet sensor reed contact in the door window detector is normally deactivated on delivery It is activated when closed for the first time via a magnet and hereafter signals its state to the alarm base station Thus the door window detector may also be operated exclusively with external magnet sensors without the supplied magnets The internal magnet contact can only be deactivated if it has been activated once already by briefly removing the batteries replacing the batteries or by deleting and re registering the sensor 29 Inaddition to the internal magnet sensor you can attach NC contacts several external sensors to the door window detec 1 2 3 tor such as when you have a wide window bank with several windows doors These must be NC contacts normally closed which must use the KL connection See page 31 figure E Figure 20 When connecting several external NC contacts they must be connected in series figure 20 D t tierminati istors Please be sure to purchase OTOL CONN eee IETMINALUNY Tesistors connect the correct sensor type To complete the monitoring NO contacts normally open can also be used on the door window detector use connection KL1 see page 31 figure 23 NO contacts They must have a potential free currentless switch 1 2 3 ing output When connecting se
93. llowing safety instructions are intended to protect you as well as the device Please take time to read through the following points 10 If you are not sure how to assemble connect and install the device or if you have doubts about its mode of operation contact a skilled technician do not attempt the assembly connection and installation yourself For safety and licensing CE reasons any unauthorised alterations to and or modi fication of the product are not permitted The product is manufactured according to protection class 2 Only a proper socket 230V 50Hz from the public power supply system may be used as a voltage source for the power supply The product is only approved for installation and operation in dry and closed indoor rooms Ensure there is sufficient ventilation and never mount or attach the FAZ 3000 2 alarm base station to easily inflammable surfaces for example wooden walls The alarm base station s power supply should never be handled with damp or wet hands This could result in a fatal electric shock If the power supply shows signs of damage then the current to the relevant socket must be switched off before the power supply is removed from the socket for example using the relevant circuit breaker Electrical devices should be kept out of the reach of children Exercise particular caution when children are around as they could attempt to poke objects into the device through the openings in t
94. ly set off by a siren or flash 19 f Closure group All sensors which directly protect exterior doors for example door window detectors or PIR motion detectors can be assigned to the so called closure group When the alarm system is armed and in the case of an alarm the sensors in the closure group initially only trigger the internal siren of the FAZ 3000 2 alarm base station the default setting for the alarm duration is 30 seconds which you can adjust Only afterwards is the normal alarm triggered for example externally via a siren and a flash RS Advantage If you forget to disarm the alarm system when you enter your house only the internal siren is set off initially You then have 30 seconds in which you can disarm the alarm system before the external siren and the alarm dialler or PC interface for example signal the alarm outside the building Disadvantage When there is a real break in this also forewarns the intruder The intruder could then attempt to destroy the alarm system or parts of the alarm system if these devices are easily accessible and are not protected against force To avoid this problem it makes sense to use the FAZ 3000 SE 2 wireless activation switch with a bolt switching contact This device disarms the alarm system when the house door is opened properly and conse quently prevents false alarms At the same time the alarm is set off without a delay if
95. m base station gt The cursor automatically jumps to the next position after the button is pressed gt You can use the C button to delete a number you entered incor rectly by mistake The service number SN is confirmed by pressing the OK button Exit the menu by pressing the C button twice This returns you to the normal display mode main level normal telephone numbers disarm 15 10 05 03 troubles al dialer al dialer trigger al dialer LNR LNR LNR 12345_ al dialer LNR disarm 15 10 05 03 If you enter a service number this will be dialled by the alarm dialler first in the case of an alarm Only afterwards is the alarm effected via the maximum number of three 97 j FAZ 3000 PC 2 PC interface settings The following settings can be carried out for the FAZ 3000 PC 2 PC interface Conditions for setting off the alarm e Silent alarm on off 1 Conditions for setting off the alarm changing the settings For the PC interface the conditions for setting off an alarm can be set in detail and dependent on the states disarmed internally armed and externally armed The PC interface is factory set to inactive or deactivated switched off That means that no alarm triggering will activate it It is up to you to set when the PC interface should trigger an alarm Tabl
96. me that remains to disarm the alarm system after the sensors in the closure group have been triggered The delay is set as follows You must be on the main level The LCD should appear as on the right for example with the time and the date Briefly press the Menu a A button on the control unit of the FAZ 3000 Z alarm base station Use the 4 and buttons to select the setup menu Confirm your selection by briefly pressing the OK button Select the ext delay menu using the 4 and buttons delay for externally armed Confirm your selection by briefly pressing the OK button The delay that is currently set is displayed on the LCD factory setting is 30 seconds Select the desired delay using the 4 and buttons You can seta value between 10 to 250 seconds in increments of 10 seconds To make a quick setting keep the 4 or button pressed for a few seconds Pressing the OK button applies the setting Exit the menu by pressing the C button twice This returns you to the normal display mode main level 74 disarm 17 25 05 02 troubles setup setup set time setup ext delay ext delay 30 sec ext delay 60 sec setup ext delay disarm 17 27 05 02 4 Programming an access code for the settings All of the FAZ 3000 2 alarm base stat
97. meets the requirements of both current national and European guidelines In order to ensure continued fulfilment of legal requirements and safe operation of this product we kindly ask you to carefully follow the instructions in this user manual Please read the user manual completely and observe the safety and operation instructions before using the product All company and product names contained herein are trademarks of their respective owners All rights reserved Should you have any further questions please contact our technical service Germany Tel no 49 9604 40 88 80 Fax no 49 9604 40 88 48 Email tkb conrad de Mon to Thur 8 00am to 4 30pm Fri 8 00am to 2 00pm Table of contents Page 1 Prescribed USE nitsicisccsissscisssaiesttssceretisateiisdseadeatssaaedospaseinasacbeetesiacdecsensonieasassenustiaaedsotl 7 2 Scope of delV e Iia r eaea aa eaaa a Macey scates bac sncntedeciadanenssceciyanceeemendeenness 8 3 Explanation Of CON Sa a r a aa aa eaa aa aA ea aE t aa Dan raaa ar aa N cranes 9 4 Safety instruct Oms a a aea epa aa ea ear ea Naa E Aaaa EE ETEEN 10 5 INGFOAUCHION sscsescisccsentsciidencsacsauvccscosunsbivacdssolesuieracssonseuasdsdiventsbcarecedestveasvendsesasuduastesssaes 12 6 System components sinia e a aaa odee aea ease aaar A 13 a FAZ 3000 2 wireless alarm base station 0 cccecceeeeeeeeeeeeeeneeeseeeseeeeeseneeeteaees 13 b FAZ 3000 FB 2 wireless remote control
98. mplete set This section offers a detailed description of the programming procedures up to the normal operation stage with the essential functions IS These are the steps that must be carried out in order to enable the basic functions of the wireless alarm system After you have carried out the steps listed in section 9 a from page 23 onwards the alarm base station s LCD has during the initial operation the display shown here in the figure on the right for example LCD is lit up disarm 0 01 1 01 Furthermore the Netz power and unscharf internally armed LEDs light up If a different display appears or an alarm signal check the following Are the batteries inserted in the alarm base station Are the alarm base station s batteries inserted in the holders with the correct polarity Are the alarm base station s batteries empty Are the wired alarm lines connected properly Are the available sensors wired correctly Is the alarm base station s casing open Also check the small contact bow in the upper half of the casing This presses on the button for the sabotage contact If the contact bow is bent the alarm base station will not recognise if the casing is shut Isthe alarm base station properly connected to the external power supply Is the plug properly inserted in the alarm base station s socket Is the power supply connected to a proper socket Is the supply volt
99. n alarm such as an alarm siren or alarm flash causes offenders to flee and also alerts neighbours and passers by to the emergency The other protection features of the house or the apartment must also be designed so as to make things as difficult as possible for the offender The longer they need to overcome an obstacle the greater the danger of being discovered Good protection therefore includes an alarm system as well as correspondingly designed house doors door locks side entrance doors for example between the house and garage or neighbouring building lockable cellar windows and their covers and so on Having an expensive specially protected house or apartment door fitted is pointless if in order to save money you only have a basic back door or patio door Further information on this can be obtained from relevant specialist firms such as door and window manufacturers as well as from police 12 6 System components To give you an insight into the variety of components which are available as part of the FAZ 3000 wireless alarm system we will use the following pages to introduce you to the individual devices and their most important functions a FAZ 3000 2 wireless alarm base station e LCD with pixel matrix display for improved readability Remote management of a maximum of 100 sensors and peripheral devices Option to connect four additional wired alarm lines as well as a wired sabotage line
100. n in the respective sensor s user manual The sensor establishes contact with the base station by sending out a radio signal The sensor s LED briefly lights up and the base station emits a short signal tone to confirm that it has received the signal 64 Close the sensor s casing e Return to the alarm base station The sensor type for example con sens type X tact motion or smoke and the sensor number X are dis played on the LCD Use the buttons on the alarm base station to enter your chosen name smoke 3 for the sensor such as the installation location in the example on the child pana right is a smoke detector that is installed in the children s room belonging to Dana it is the third sensor to be registered by the user gt To enter the letters use the 2 9 buttons each of which represents several letters click through as with a mobile phone by repeatedly and quickly pressing the same button gt Numbers and umlauts can also be found on the buttons for instance gt Use the 0 button to enter a space character gt Special characters can be entered using the 4 and buttons gt You can use the Meni a A button to switch between lower and upper case gt The cursor automatically jumps to the next position approx one second after the last button was pressed gt You can use the C button to delete a ch
101. n the figure on the right you can use the 4 and buttons to switch between the three different states disarmed internally armed and ex ternally armed Pressing the OK button applies the new settings Exit the menu by pressing the C button twice This returns you to the normal display mode main level disarm 20 27 15 02 troubles al dialer al dialer trigger disarm 000_ int arm 0 000_ ext arm I ext arm al ext arm 1101 ext arm 1101_ t al dialer trigger disarm 15 43 09 02 91 2 Silent alarm on off In the case of a silent alarm the FAZ 3000 Z alarm base station transmits the alarm via the alarm dialler and or the PC interface without the intruder noticing the alarm If transmission of the alarm is not possible the internal and external sirens are activated after wards in line with how they have been set EJ Please note You can find the silent alarm on off setting in the alarm dialler s settings and in the PC interface s settings Here exactly the same setting applies This means If you switch the alarm dialler s silent alarm on it is also au tomatically activated on the PC interface also see page 100 To set the silent alarm function proceed as follows You must be on the main level The LCD should appear a
102. nd buttons to select the ext siren menu external siren Confirm your selection by briefly pressing the OK button Select the dur siren menu using the 4 and buttons siren duration Confirm your selection by briefly pressing the OK button The duration that is currently set appears on the LCD factory set to 60 seconds Use the 4 and Y buttons to select the required duration You can set the duration to a value between 10 and 300 seconds in increments of 10 seconds To make a quick setting keep the 4 or Y button pressed for a few seconds Pressing the OK button applies the setting Exit the menu by pressing the C button twice This returns you to the normal display mode main level disarm 21 57 08 02 troubles ext siren ext siren trigger ext siren dur siren dur siren 60 sec dur siren 90 sec ext siren dur siren disarm 22 10 08 02 87 3 Setting the duration for the external flash The duration for the external flash controlled via the FAZ SI is factory set to 20 minutes however you can adjust this to a time between 1 and 100 minutes To set the duration for the external flash proceed as follows You must be on the main level The LCD should appear as on the right disarm for example with the time and the dat
103. nsor confirmation as a trouble sensor lost I then re registered Carry out the following steps to delete a sensor You must be on the main level The LCD should appear as on the right for example with the time and the date Briefly press the Men a A button on the operating unit of the FAZ 3000 2 alarm base station Use the 4 and buttons to select the sensors menu Confirm your selection by briefly pressing the OK button Use the 4 and buttons to select the sensors delete menu Confirm your selection by briefly pressing the OK button The first sensor that was registered with the alarm base station is displayed Select the sensor that you wish to delete using the 4 and buttons or the device using the gt button in the example on the right this is the door window detector in the bedroom on window 1 which was reg istered as the fourth sensor Press the OK button briefly The deletion of the sensor must be re confirmed See the figure on the right Press the OK button Selected sensor is deleted Delete a sensor Press the C button Selected sensor is not deleted Cancel Pressing the OK or C button returns you to the sensor list and another sensor can now be deleted Once you have deleted all the sensors the alarm base station s deletion mode can be exited by pressing the C b
104. nstallation location 23 2 Installing the alarm base station 23 3 Alarm base station cabling 25 4 Completing the installation c 26 5 Initial operation of the alarm base station ccccccescceeeeeeeeeeeeeeeeeeeeeeseeeeeeee 28 b Installing the FAZ 3000 TF 2 door window detector cccceeceeeeeeeeeeeeeeeeeeeee 29 T Installation NOt6S jes ccccieastiit neds aioe dee ciasa ite nee e r ad iin 29 2 Installing the FAZ 3000 TF 2 door window detector c cecceeeeeeeeeeeeee 31 c Installing the FAZ 3000 PIR 2 PIR motion detector cccccceeeeeeeeeeeeeseeeeeteees 32 Ta Installation NOteS cc lt ccciscceeiteateus catieceeriaea Heeb ante ree e a s 32 2 Installing the FAZ 3000 PIR 2 PIR motion detector 34 d Preparing the FAZ 3000 FB 2 remote Control ccceceeeeeeeeeeeeeeeseneeeeseeseeeees 36 10 Initial operation and programming cccceeceeeeeeeeseeeeeneeeeeeeeeeeeeeeeeeeeseeeeeseeeeeeeees 37 a Displays amp controls of the FAZ 3000 2 alarm base station ceceeeeteees 37 b Operating structure of the FAZ 3000 2 0 ececeeccceeeeeeeeeeeeneeeeeeeeeeeeeeeaeeseteeeeaee 38 1 Ma inlevel saitui nun e aE dues iE aE a TNA 38 2 5 Men l vel gdire oa niaii E aE aaa es 39 11 Programming examples for the complete Set sccccsssceseeeeeeesseeeeeeeeneeeeeees 42 a Setting
105. nts of a window or an entire glass facade can be protected using a single door window detector It is also possible to connect external sensors to this detector for example magnet sensors glass break sensors safety shut off mats or similar A PIR motion detector recognises movement when an intruder does not enter a house or apartment through windows or doors for example but gains access by another means unsecured skylight cellar window and so on Using a PIR motion detector a room with a maximum length of up to approximately 10 12m can be protected Atleast one smoke detector should be installed in every room depending on the size of the room and how it is arranged The installation location of a smoke detector is dependent on the air circulation in the room not in the corners of rooms not behind curtains Do not forget that additions to the building or outbuildings such as the garage summer house or bike shed can also be protected by the alarm system Thanks to radio transmission and battery operated sensors protection is very simple sensors must not get wet or damp 21 b Example for the protection of a bungalow livingroom ext garage
106. o and closure group yes no can also be modified retrospectively or the settings can be checked You must be on the main level The LCD should appear as on the right for example with the time and the date Briefly press the Men a A button on the operating unit of the FAZ 3000 2 alarm base station Use the 4 and buttons to select the sensors menu Confirm your selection by briefly pressing the OK button Use the and buttons to select the sensor attributes menu See the figure on the right Confirm your selection by briefly pressing the OK button The first sensor that was registered with the alarm base station is displayed Use the 4 and buttons to select the sensor whose attributes you wish to modify or check Briefly press the OK button Afterwards you can change the attributes You can use the gt button to set the sensor as an internal sensor intern Y or external sensor intern N jntern N External sensor alarm is set off for internally armed and externally armed jntern Y Internal sensor alarm is only set off for externally armed For more detailed information see page 46 By pressing the 4 button you can access the closure group settings the N onthe upperlineis underlined Use the 4 and buttons to change the entry line Using the gt bu
107. of the police fire brigade or similar Instead only ever enter private numbers for example neighbours mobile phone etc Abuse of police fire brigade etc telephone numbers can lead to charges being filed To enter the numbers proceed as follows You must be on the main level The LCD should appear as on the right for example with the time and the date Briefly press the Men a A button on the control unit of the FAZ 3000 Z alarm base station Use the 4 and buttons to select the al dialer menu Confirm your selection by briefly pressing the OK button Select the telephone number that you wish to enter using the 4 and buttons telephone number 1 2 or 3 Confirm your selection by briefly pressing the OK button The cursor _ appears on the upper left of the LCD Now enter the desired telephone number using the number buttons 0 to 9 on the alarm base station gt To enter a dialling pause 1 second press the gt button A dash representing this appears on the LCD gt The cursor automatically jumps to the next position after the button is pressed gt You can use the C button to delete a number you entered incor rectly by mistake The telephone number is accepted when you press the OK button If you now wish to enter the second and or third telephone number select the desired telephone number using the 4 and
108. one of the sensors is triggered 20 8 Planning the installation a General notes on planning First of all you should use the floor plan of the building that you wish to monitor to make a plan of which doors windows rooms etc are to be protected and in which way Make a sketch and mark on it the type and position of each sensor This will also help you to assess the need for additional sensors Give the sensors names A maximum of 11 characters letters are available per sensor for later registration with the alarm base station Example Livingr W1 for Living room Window 1 Also note down any additional information next to the sensor for example the type internal external closure group This will be a useful aid later when you register the sensors with the alarm base station Advice on positioning the alarm base station and the sensors The alarm base station itself should be installed at a central location in the middle of the surveillance area so that all transmission paths are kept short A suitable location for ex ample is the hallway of an apartment or house Choosing a secured area such as a separately lockable storeroom as the installation location is even better In any case the alarm base station must be located in an area which is adequately protected by alarm sensors as otherwise an intruder could approach the alarm base station unhindered and switch it off or destroy it Several caseme
109. onfirm your selection by briefly pressing the OK button The first sensor that was registered with the alarm base station is displayed Press the gt button until line 1 is displayed If the alarm line has already been assigned a name this will be displayed on the lower display line Skylight in the example on the right You are now in the list of all the wired alarm lines line 1 to line 4 and sabotage Use the 4 and buttons to select the alarm line whose attributes you wish to modify or check for example line 3 in the figure on the right No attributes can be modified displayed for the sabotage line here there is no allocation to internal external sensor or closure group Briefly press the OK button Afterwards you can change the attributes You can use the gt button to set the sensor as an internal sensor intern Y or external sensor intern N intern N External sensor alarm is set off for internally armed and externally armed intern Y Internal sensor alarm is only set off for externally armed For more detailed information see page 46 104 disarm 17 44 19 02 troubles sensors sensors add sensors attributes contact 1 livingr w1 line 1 skylight line 3 CellarDoor close N intern N By p
110. ontact of a door window detector the sensor name is displayed To activate carry out the following steps You must be on the main level The LCD should appear as on the right disarm for example with the time and the date 16 55 14 12 e Briefly press the Meni a A button on the operating unit of the FAZ troubles 3000 2 alarm base station e Select the run test menu using the 4 and buttons run test e Confirm your selection by briefly pressing the OK button run test active Caution Wait at least 10 minutes before you test the sensors function and start the test procedure described below The alarm base station must first inform all the sensors that a function test is to be carried out status signals between the alarm base station and the sensors are transmitted approx every 10 minutes Otherwise a situation could arise where a sensor does not send a return signal to the alarm base station and you then needlessly search for the cause of the error The test procedure is carried out as follows Open the magnetic contact of a door window detector The LED on the door window detector briefly lights up and the alarm base station emits a short alarm signal this may not be audible depending on how far you are from the alarm base station The magnetic contact can be closed again Finally check the alarm base station s LCD to see whether the sensor contact 1
111. or atleast 5 6 seconds The LED lights up for approx 2 seconds and goes out Then release the button The LED starts to blink or remove the remote control s batteries for approx 1 minute Enter the code on the remote control see page 36 e Reregister the remote control with the alarm base station see pages 47 52 and 53 e Using the FAZ 3000 FB 2 remote control to set off an attack alarm Inthe event of an attack the remote control can be used to immediately set off an alarm This attack alarm can be signalled via the various components of the FAZ 3000 wireless alarm system for example using an external siren via the FAZ 3000 SI 2 siren control RS Make sure that you program the settings for the attack alarm trigger to suit your own requirements In the factory default setting only the attack alarm is activated by means of the FAZ 3000 2 alarm base station s internal siren see pages 78 79 How does the attack alarm function On the remote control two button combinations are each joined by a dashed line Button combination 1 Button ext external arm and button unscharf disarm Button combination 2 Button int internal arm and button unscharf disarm Simultaneously pressing one of these button combinations triggers the attack alarm RS Please note Simultaneously pressing all three buttons on the FAZ 3000 FB 2 remote control does not trigger an attack al
112. or external arming Enter house code when using several systems in close proximity for example in your own or a neighbour s home Run test see page 56 57 e Sensors function test e Display on the base station Int siren see from page 78 This menu allows you to adjust the internal siren s settings e Conditions for setting off the alarm Alarm Signal duration when internal arming is confirmed e Signal duration when external arming is confirmed Ext siren see from page 84 Carry out the settings for the external siren in this menu Conditions for setting off the alarm e Duration for siren e Duration for flash 40 Alarm dialler see from page 89 This menu is for configuring the alarm dialler s settings Conditions for setting off the alarm Silent alarm on off Enter telephone number 1 Enter telephone number 2 Enter telephone number 3 Entering the dialout number Entering the alarm dialler s access code for remote control via a telephone Remote control Allow use of remote control and configuration of automatic call acceptance Entering a service number SN for connecting to an emergency call centre note this function may not be available with some versions of the alarm base station PC interface see from page 98 Set the attributes for the PC interface using this menu Conditions for setting off the alarm e Silent alarm on off 41 11 Programming examples for the co
113. or peripheral device s battery level If the battery is low this is indicated as a trouble on the alarm base station s display 54 a Testing the remote control You can test the remote control by using it to operate the alarm base station Briefly press the int button 2 once The LED on the remote control 3 lights up briefly The base station emits a signal tone to acknowledge receipt and switches from the disarmed state to the internally armed state If the signal tone can be heard from outside the house this confirms that the keypress on the remote control has been received correctly EJ Figure 35 The internally armed function provides protection of the exterior of a building when you wantto protect yourself from intruders whilst you are inside your house for example at night You can move around your house freely whilst the exterior doors windows are kept under surveillance If there is a trouble for example the alarm base station s batteries are empty or not inserted or if a magnetic contact is not closed for example a window is open then the arming is refused on the first press of the int button 2 Only pressing the int button 2 for a second time forces a switch to internally armed It is possible to close the magnetic contact later on for example closing the window during the night without any problem The alarm is set off only when it is opened
114. page 59 Displays which sensors have troubles or when the alarm base station s batteries are empty for example e Possible troubles Battery empty contact open sabotage Removal of the cause of the trouble on the sensor or alarm base station if its batteries are empty Events see page 63 e Calls the last 1000 events with date time and sensor name Events are for example arming disarming alarm signals etc Sensors see from page 64 The sensors menu manages the individual sensors and consists of four sub menus Add Register sensor and assign names Delete Delete sensors Names Modify the name of the sensor Attributes Entry or modification of sensor attributes internal external closure group PIR sensitivity Service see page 71 Servicing the sensors for example replacing the batteries or adjusting the wiring without triggering a sabotage alarm Sensor information is retained when the batteries are replaced 39 Setup see from page 72 The following basic settings for the alarm base station can be carried out in this menu Settime date DCF configuration for external DCF receivers on off or reception check this setting is only available when external DCF receiver is connected Set the delay for externally armed or closure group Enter security code for alarm system settings Enter security code for internal arming e Enter security code f
115. pplies the new settings Exit the menu by pressing the C button twice This returns you to the normal display mode main level 86 disarm 15 17 09 02 troubles ext siren ext siren trigger disarm 000_ int arm 0 000_ ext arm alata ext arm 1111 ext arm 1101 ext arm 1101_ t ext siren trigger disarm 15 43 09 02 2 Setting the duration for the external siren The duration for the external siren controlled via the FAZ 3000 SI 2 is factory set to 60 seconds however you can adjust this time to a value between 10 and 300 seconds Caution The maximum duration for an acoustic alarm that sounds outside is restricted by law to 3 minutes an external flash can signal for longer This may vary at health resorts for example Therefore as a precaution check this out with your local council The duration for indoor areas is not normally affected by this restriction However if the internal alarm signal is very loud and is also clearly audible outside then the legal restriction may apply here too To set the external siren s duration proceed as follows You must be on the main level The LCD should appear as on the right for example with the time and the date Briefly press the Men a A button on the control unit of the FAZ 3000 Z alarm base station Use the 4 a
116. r or the FAZ 3000 RM wireless smoke detector e rem con FAZ 3000 FB 2 remote control e siren FAZ 3000 SI 2 wireless siren interface e rem sw FAZ 3000 SE 2 wireless activation switch e al dialer FAZ 3000 AW 3 wireless alarm dialler e PC interf FAZ 3000 PC 2 wireless PC interface sensor 1 clear rem con 1 clear siren 1 clear rem sw 1 clear al dialer clear PC interf clear 47 3 Registering the FAZ 3000 TF 2 door window detector The alarm base station should be prepared as described on the previous page 47 The LCD appears as shown on the right sensor X clear RS Here X is the number of sensors that have already been registered plus one if no sensor has been registered yet then X 1 Go to the first door window detector that you want to register with the alarm base station After installing the door window detector as described in section 9 b pages 29 to 31 the casing is open and the batteries have not yet been inserted e Ifyou wish to operate additional NC contacts on the KL2 connection see pages 30 and 31 then you should remove the wire jumper When connecting several external NC contacts they must be connected in series Insert 3 AAA batteries into the 3 battery holders making sure that the polarity is correct See figure 32 T
117. ractive holes in the wrong location 30 2 Installing the FAZ 3000 TF 2 door window detector Open the casing the 2 casing halves are secured by 2 catches A in the figure on the right Using a flat screwdriver carefully push the 2 catches approx 1 millimetre inwards First press one catch inwards and pull the casing approx 1 2 millimetres apart at this location Afterwards push in the second catch the casing can now be opened B Before installing the FAZ 3000 TF 2 door window detector at the ce desired location the cables of the external sensors NC or NO contacts if available must be inserted c There are 2 openings C on the back of the door window de tector through which the cables can be led inwards In the door window detector the cables are guided under the battery compartment for the LR44 button cells to the screw terminal strips A KL1 For external NO contacts connection is always active a i irrespective of whether disarmed internally armed or externally armed is set the alarm base station immediately triggers an alarm when the 2 screw terminals are connected Figure 22 KL2 For external NC contacts if KL2 is used the jumper in the terminal must be removed 33 Attach the door window detector using the enclosed double sided z z tape 8 8 Or you can attach it using a screw through opening B
118. ral 100 recycled paper Bleached without chlorine http www conrad com Imprint These operating instructions are published by Conrad Electronic SE Klaus Conrad Str 1 D 92240 Hirschau Germany All rights reserved No reproduction including translation is permitted in whole or part e g photocopying microfilming or storage in electronic data processing equipment without the express written consent of the publisher The operating instructions reflect the current technical specifications at the time of print We reserve the right to change the technical or physical specifications Copyright 2007 by Conrad Electronic SE Printed in Germany OPERATING INSTRUCTIONS Version 01 07 CE FAZ 3000 Z Wireless alarm base station Item no 75 03 31 Complete set FAZ 3000 2 wireless alarm base station FAZ 3000 FB 2 wireless remote control FAZ 3000 TF 2 wireless door window detector FAZ 3000 PIR 2 wireless PIR motion detector Item no 75 03 30 Consisting of This user manual belongs to this product It contains important information specific to its operation and handling Please bear this in mind when passing on the product to a third party Therefore keep this user manual for future reference A contents list can be found in the table of contents on page 3 QINRAD ELECTRONIC Introduction Dear customer Thank you for purchasing this product This product
119. registered again afterwards Once the new batteries have been inserted the sensor s LED briefly blinks once The radio connection to the alarm base station has been established and checked Instead of replacing the batteries you could also modify the wiring of a door window detector in order to connect additional external NO NC contacts for example Once you have finished replacing the batteries or made changes to the wiring close the sensor s casing again The service is completed by pressing the OK button You are now in the sensor listagain You can use the 4 and buttons to select another sensor or select a device using the gt button You can exit the service mode by pressing the C button three times This returns you to the normal display mode main level disarm 17 25 20 03 troubles service contact 1 livingr w1 contact 4 bedr w1 contact 4 service contact 4 bedr w1 disarm 17 47 20 03 71 e Configuration setup menu item The setup menu item consists of the following submenus set time Set the time and date e DCF setup DCF setup on off reception check RS This menu item is only available when a DCF receiver is connected e ext delay Set the delay for externally armed or the closure group e code setup Enter security code for a
120. ressing the 4 button you can access the settings for the closure group the N on the upper line is underlined use the 4 and buttons to change the entry line Using the gt button you can select whether the sensor belongs to the closure group Y or not N For further information see pages 20 and 46 Once you have made the settings or carried out a check briefly press the OK button This returns you to the alarm line list Use the 4 and buttons to select a further alarm line whose attributes you wish to modify or display check You can exit the attributes mode by pressing the C button three times This returns you to the normal display mode main level close N intern N close Y intern N line 3 cellarDoor line 1 skylight disarm 17 58 19 02 105 15 Disclaimer In selecting the FAZ 3000 wireless alarm system you have purchased a particularly high quality and reliable alarm system IS However even this system has its constraints which for the sake of completeness we would like to point out to you here This should enable you to form your own opinion on the reliability of the system which is as objective as possible e Internal or external parasitic induction can cause every electronic device to stop working regardless of how extravagantly equipped the device is and its security provisions T
121. rm base station s main menu If disarm appears on the LCD then the trouble has been removed Otherwise check again whether any further troubles exist and if so which troubles are present for instance another window may be open and so on If there are no troubles no troubles appears when you press the OK button in the troubles menu see above 62 cont open 18 06 29 12 troubles contact 1 livingr w1 preventions ext arm contact 1 livingr w1 contact open disarm 18 10 29 12 no troubles b Events The alarm base station s memory can store the last 1000 events When 1000 events is exceeded the oldest events are automatically deleted The events display can be very useful for example in reconstructing an alarm event with the date time sensor etc Events are Sabotage Alarm Contact open closed Attack Smoke The events can be called as follows State switching between disarmed internally armed and externally armed e You are in the main menu and the LCD appears as shown on the right disarm for example 20 06 29 12 Briefly press the Men a A button The troubles menu is displayed troubles on the LCD e Use the 4 and buttons to select the events menu events e Briefly press the OK button The last event appear
122. s also only have a short battery life You should only ever use batteries alkaline in the alarm base station itself and not recharge able batteries As a result of the alarm base station s many functions a certain amount of preparation time for initially programming and operating the device is inevitable As in the case of a video recorder DVD player or television however you only need to use many of the functions once during the initial installation If you experience any assembly installation or programming problems it may be sensible to contact a skilled technician Although you may initially have doubts about the costs associated with this remember that when installed by a skilled technician your system will offer better protection against break in and theft as a skilled technician can immediately see where and how to optimally secure your home The type of high quality house doors that are normally used in new or renovated buildings mostly offer adequate protection against break in Security locks security glass multiple locks door fall hooks or stopper dowels make it difficult for a burglar to get in here takes too long to open the door or creates a lot of noise However a few metres away side entrance doors terrace doors windows balcony doors cellar windows and even garages can be found which are normally poorly secured For example it only takes a few seconds to gain access to an apartment relatively
123. s on the LCD the sabotage example on the right displays a sabotage attempt or opening of the sensor 17 54 29 12 casing at 17 54 on the 29 December Using the 4 and buttons you can view the last 1000 events for contact example the opening of the window at 17 10 on 29 December 17 10 29 12 Button Older events Button 4 Recent events Briefly pressing the gt button displays the device or sensor that trig gered the event in the example on the right it was the door window detector in the living room on window 1 Pressing the gt button again brings you back to the list of events Check contact 1 livingr w1 contact other events using the 4 and Y buttons 17 10 29 12 To return to the normal display main level of the alarm base station disarm briefly press the C button 20 09 29 12 63 c Sensors The sensor menu item has a total of four submenus Add Register sensor and enter names Delete Delete sensors Names Modify a sensor s name Attributes Modify a sensor s attributes Internal sensor yes no Closure group yes no Furthermore the peripheral devices such as the alarm dialler PC interface siren interface second remote control etc are all managed via the sensors menu You can find the procedures for managing these devices in their respective specifications 1 Add sensors On pages 46
124. s on the right for example with the time and the date Briefly press the Men a A button on the control unit of the FAZ 3000 Z alarm base station Use the 4 and buttons to select the al dialer menu Confirm your selection by briefly pressing the OK button Use the 4 and Y buttons to select the silent al menu silent alarm Confirm your selection by briefly pressing the OK button The state that is currently set appears on the LCD factory set to no Use the 4 and Y buttons to select the setting you require Silent alarm is switched on Silent alarm is switched off yes no Pressing the OK button applies the setting Exit the menu by pressing the C button twice This returns you to the normal display mode main level Press the Mend a A button lower left The following appears 92 disarm 12 10 18 02 troubles al dialer al dialer trigger al dialer silent al silent al no silent al yes al dialer silent al disarm 12 12 18 02 3 Entering the telephone numbers Here you can enter up to three telephone numbers maximum of 22 digits that will be dialled one after the other when a silent alarm is triggered Only DTMF dialling is used multi frequency dialling tone dialling Never enter the telephone number
125. s the Ment a A button on the control unit of the FAZ 3000 troubles Z alarm base station e Use the 4 and buttons to select the al dialer menu e Confirm your selection by briefly pressing the OK button Select the prefix menu using the 4 and buttons Confirm your selection by briefly pressing the OK button The state that is currently set appears on the LCD factory set to no Use the 4 and buttons to select the setting you require yes Dialout number switched on via 0 no Dialout number switched off Pressing the OK button applies the setting Exit the menu by pressing the C button twice This returns you to the normal display mode main level 94 al dialer al dialer trigger al dialer prefix prefix no prefix yes al dialer silent al disarm 15 23 23 02 5 Enter the alarm dialler s access code for remote control The alarm base station can be controlled remotely from outside via the alarm dialler and using a telephone disarmed internally armed and externally armed switching RS An access code is required to allow this remote control operation Make a note of the code and keep it in a safe place For information on how to operate the alarm dialler please observe the alarm dialler s user manual
126. se station 2 Installing the alarm base station When mounting the alarm base station to a wall use 3 screws and dowels supplied First of all attach 2 screws horizontally and 134mm apart at the desired installation location Depending on the state of the wall you may first need to drill 2 holes 6mm and insert dowels Be careful not to accidentally damage any power sup ply lines gas or water pipes as this may pose a life threatening danger 4 Then use a suitable screwdriver to screw in the two screws Ensure Lal that the distance between the underneath of the screw head and the wall is approx 3mm See the figure on the right 3mm ne The alarm base station is hung on the screws from the two installation slots on the back Figure 11 The third screw must be screwed in from the inside through an opening in the lower part of the casing RS This means that the alarm base station cannot be removed from the wall without the casing first being opened sabotage alarm if casing is opened 23 To mark the drill hole for this screw or to tighten the screw the casing of the alarm base station must be opened All the larger casings of the FAZ system comprise a front shell and a rear shell which are connected by 2 catches on the right side A catching system on the left side of the casing which is comprised of catches on the front shell and catch slots on the rear shell serves to close the half shells i
127. t in time you need to reset the alarm base station to the delivery state for example if you first tested the components of the wireless alarm system next to each other on a table and you now wish to carry out the real installation proceed as follows gt Disconnect the power supply from the supply voltage gt Open the alarm base station deactivate the sabotage alarm using the unscharf disarm button Remove the batteries and wait a few seconds Insert the batteries again observing the correct polarity Close the casing of the alarm base station Press and hold the 8 tuv button Plug the power supply into the socket again Release the 8 tuv button vvvvvyv The alarm base station emits a short signal tone the LEDs then light up and the LCD is tested First of all the software version of the alarm base station s installed v1 3 operating system appears on the LCD for example V1 3 Afterwards Init appears briefly on the display indicating Init that the alarm base station has been reset Subsequently Sprache deutsch language German appears Sprache on the display Here you can select the language for the command deutsch menu deutsch German and english English are possible RS Please note that in the user manual it is assumed that the language for the command menu is set to english You can select the language for the
128. t you to the fact that disposal via the household rubbish ys is prohibited The identifiers for the respective heavy metals are Cd cadmium Hg mercury Pb lead identifier is on the battery rechargeable battery for example under the rubbish bin icons on the left You can return your used batteries rechargeable batteries free of charge to any authorised disposal station in your area in our stores or in any other store where batteries rechargeable batteries are sold By doing so you comply with your legal obligations and also make a contribution to environmental protection 108 18 Tips and notes You can use rechargeable batteries in the sensors However you need to bear in mind that their battery life is shorter then with conventional high quality alkaline batteries as a result of the lower capacity and the lower voltage battery 1 5V rechargeable battery 1 2V Recharge able batteries are also very sensitive to temperature This means that rechargeable batteries in external sensors a PIR motion detector in a garage for example do notfunction fora particularly long time in the winter The use of rechargeable batteries can also result in reduced ranges due to the lower output voltage In order to ensure safe operation an adequate range and a longer period of operation we therefore recommend that you use conventional batteries Make absolutely sure that these batteries are alkaline batteries Cheap zinc carbon batterie
129. table installation location according to the local conditions at a height of approx 1 8m to 2m if necessary this can also be higher or lower 32 Do not expose the PIR motion detector to direct sunlight car headlights and so on Please also refrain from installing it near a heat source such as above a radiator for example The heat source could disturb the PIR motion detector and rising environmental temperatures can also reduce its sensitivity The detection areas should be aimed at a wall or the floor but not directly towards windows heaters or other sources of heat The effectiveness of the detection depends on the temperature difference between the moving object and its respective background Detection through glass is not possible When installing the PIR motion detector make sure that you do not position it directly on or near large metal objects heaters or aluminium laminated walls such as those found in prefab ricated houses as this reduces the wireless range 33 2 Installing the FAZ 3000 PIR 2 PIR motion detector The PIR motion detector is equipped with a bracket which means that you can mount it to a wall orto a ceiling As the motion detector can be adjusted 45 degrees when itis in its bracket the detection area may be set at almost any angle from the wall and may also be subsequently adjusted Ceiling installation however allows the detector to be freely mounted in a room in order to
130. tance gt Use the 0 button to enter a space character gt Special characters can be entered using the 4 and buttons gt You can use the Meni a A button to switch between lower and upper case gt The cursor automatically jumps to the next position approx one second after the last button was pressed gt You can use the C button to delete a character you entered by mistake Once you have fully entered the name you require press the OK button Use the gt button to set the PIR motion detector as an internal sensor intern Y or an external sensor intern N jntern N External sensor alarm is set off for internally armed and externally armed jntern Y Internal sensor alarm is only set off for externally armed For more detailed information see page 46 By pressing the 4 button you can access the closure group settings the N on the upper line is now underlined Using the gt button you can select whether the PIR motion detector belongs to the closure group Y or not N For further information see pages 20 and 46 Press the OK button to access the sensitivity settings The response sensitivity of the PIR motion detector can be set to a value between 1 and 4 whereby 4 represents the highest sensitivity The response sensitivity is factory set to 3 Use the 4 or
131. ting mode In the disarmed operating mode all sensors are deactivated except for the smoke detectors which are always active You can move around your house freely without setting off the alarm RS The alarm is always set off when a smoke detector or one of the glass break sensors connected to a door window detector is triggered e Internally armed operating mode This provides protection of the exterior of a building This protects you against intruders from outside at night for example whilst you are in your house You can move around freely within your house while the exterior shell of the house doors windows etc is monitored e Externally armed operating mode This operating mode serves to monitor a house whilst it is unoccupied The indoor rooms are also monitored for example via PIR motion detectors RS external sensor assignment setting the sensor attribute in the alarm base station s Intern N menu Sensor is triggered for internally armed and externally armed internal sensor assignment setting the sensor attribute in the alarm base station s Intern Y menu Sensor is only triggered for externally armed 18 d Arming The alarm system can be armed using the following components Directly on the alarm base station with adjustable arming delay time e FAZ 3000 FB 2 wireless remote control e FAZ 3000 SE 2 wireless activation sw
132. to 53 you will find a very detailed description of the registration procedure for the initial installation of the complete set alarm base station with door window detector PIR motion detector and remote control Above all however make sure that you observe the sensor s user manual and page 47 of this user manual If you purchase a new sensor such as an additional smoke detector PIR motion detector or door window detector then this can be registered with the alarm base station as follows e You must be on the main level The LCD should appear as on the right disarm for example with the time and the date 10 20 05 02 e Briefly press the Men a A button on the operating unit of the FAZ troubles 3000 2 alarm base station Using the 4 and buttons select the sensors menu See the figure sensors on the right e Confirm your selection by briefly pressing the OK button sensors sensors add is displayed on the LCD add e Press the OK button again The symbol X stands for the number of sensor x the next free sensor X number of sensors that have been registered clear up to now 1 Now you may have to select the device type that you wish to register using the gt button See page 47 Go to the sensor that you wish to register and insert the batteries with the correct polarity in the battery compartment you will find a detailed descriptio
133. ton on the control unit of the FAZ 3000 troubles Z alarm base station e Select the int siren menu using the 4 and buttons internal int siren siren See the figure on the right Confirm your selection by briefly pressing the OK button int siren trigger e Select the ext conf menu using the 4 and buttons external int siren arming confirmation ext conf Confirm your selection by briefly pressing the OK button ext conf The signal duration that is currently set appears on the LCD factory set 1 0 sec to 1 0 seconds e Use the 4 and buttons to select the required signal duration You ext conf can set this to a value between 0 and 5 seconds in increments of 0 2 3 0 sec seconds To make a quick setting keep the 4 or Y button pressed for a few seconds Pressing the OK button applies the setting int siren ext conf Exit the menu by pressing the C button twice This returns you to the disarm normal display mode main level 21 55 08 02 83 h Settings for the FAZ 3000 SI 2 external siren The following settings can be programmed for the external siren controlled via the wireless alarm system s FAZ 3000 SI 2 wireless siren control Conditions for setting off the alarm e Duration for siren e Duration for flash 1 Conditions for se
134. tons are for arming intern scharf internally armed and extern scharf externally armed or for disarming unscharf disarmed the alarm base station 37 b Operating structure of the FAZ 3000 2 alarm base station In order to make programming simple the FAZ 3000 Z alarm base station has menu guided programming with several levels similar to a mobile phone for example Main level Menu level Sub menus amp programming Main level RS The main level is the normal display mode where no button is pressed and no function is selected Examples State disarmed disarm 23 45 15 08 Active LEDs LCD State internally armed int arm 23 45 15 08 Active LEDs LCD State externally armed ext arm 23 45 15 08 38 Active LEDs Display Netz power unscharf disarmed State time date Netz power intern scharf internally armed State time date Netz power extern scharf externally armed State time date Menu level The menu level can be called by pressing the Men a A button The following menu items can be called press 4 or button in order to select the next or previous menu item troubles events sensors service 4 setup run test int siren ext siren gt alarm dialler PC interf 9 Troubles see from
135. tteries Can also be operated using a power supply Dimensions 123mm x 240mm x 50mm W x H x D j FAZ 3000 DCF DCF receiver no figure Connao Faz AW Figure 8 Onnan FAZ PC Figure 9 Receives DCF signals transmitter close to Frankfurt am Main Germany range ofup to 1500km Automatic setting of time and date on the alarm base station 16 7 System description a Basic functions The FAZ 3000 wireless alarm system is suitable for protecting against break in and fire in apartments and private homes and is also suitable for attack and emergency alarms for en dangered persons and those requiring assistance It was developed using the latest microproc essor and wireless technology and is relatively simple to install and operate despite its multitude of features Configuration is carried out on the FAZ 3000 2 alarm base station itself or using the separately available FAZ 3000 PC PC interface A freely chosen name max 11 characters can be allocated to each sensor of the wireless alarm system In the event of an alarm the location and the sensor that triggered the alarm can consequently be identified very quickly The wireless technology makes the system very simple to install as the laborious laying of cables is almost completely dispensed with A maximum of 100 wireless sensors can be operated 4 additional wired alarm lines and a wired sabotage line are also available so that existing wired
136. tting off the alarm changing the settings For an external siren the conditions for setting off an alarm can be set in detail and dependent on the states disarmed internally armed and externally armed Useful settings are already preset in the factory however you can change these settings to suit your own personal requirements The external siren is only active when you are not at home thus for externally armed The external siren is not activated for internally armed and disarmed If required however this can be changed Table containing the factory settings for the disarmed state Disarmed state Alarm when Alarm when Alarm upon Alarm upon Alarm upon int armed ext armed donoe sabotage attack e Itis not possible to trigger the external siren for internally armed and externally armed because of the current disarmed state each set to If a smoke detector is triggered no alarm is effected via the external siren set to 0 Ifa sabotage contact is triggered no alarm is effected via the external siren set to 0 In the event of an attack no alarm is effected via the external siren set to 0 84 Table containing the factory settings for the internally armed state Internally armed state Alarm when Alarm when Alarm upon Alarm upon Alarm upon int armed ext armed smoke sabotage attack detection
137. tton you can select whether the sensor belongs to the closure group Y or not N You can find further information on this on pages 20 and 46 Once you have made the settings or carried out a check briefly press the OK button In the case of a door window detector you now return to the sensor list Another sensor can be selected using the 4 and buttons The response sensitivity setting is displayed for a PIR motion detector disarm 15 25 05 02 troubles sensors sensors add sensors attributes contact 1 livingr w1 contact 4 bedr w1 close N intern N close N intern N contact 4 bedr w1 69 The response sensitivity of the PIR motion detector can be set to a value sensit 3 between 1 and 4 whereby 4 represents the highest sensitivity The response sensitivity is factory set to 3 Use the 4 or button to select the value you require The sensitivity setting is confirmed using the OK button motion 4 Finally you return to the sensor list where you can use the 4 and garage buttons to select another sensor whose attributes you wish to modify or check Youcan exit the attributes mode by pressing the C button three times disarm This returns you to the normal display mode main level 14 10 05 02 70 d Servi
138. ttons the sensors which prevent internal arm ing can be scanned individually and in succession In the example figure on the right the door window detector in the living room is the cause You can use the gt button to display the troubles for the selected sensor As you can see in the example on the right the magnet contact is open the window is probably open however the magnet that was stuck on may also have fallen off If necessary remove the trouble for example close the window stick the magnet contact on again and so on Return to the alarm base station and keep pressing the C button until you return to the alarm base station s main menu If disarm appears on the LCD then the trouble has been removed Otherwise check again whether any further troubles exist and if so which troubles are present for instance another window may be open and so on If there are no troubles no troubles appears when you press the OK button in the troubles menu see above cont open 18 06 29 12 troubles contact 1 livingr w1 preventions int arm contact 1 livingr w1 contact open disarm 18 10 29 12 no troubles 61 3 Scanning troubles amp open contacts that prevent externally armed arming You can use this scanning option to determine what it was that prevented the externally armed armin
139. up menu Confirm your selection by briefly pressing the OK button Select the code intern menu using the 4 and buttons code for switching to internally armed Confirm your selection by briefly pressing the OK button You can now use the number buttons to enter any four digit code for example 1234 or 9876 and so on You can use the C button to correct any incorrect entry you have made If you want to switch off the access code no code request for internally armed enter 0000 as the code Pressing the OK button applies the setting Exit the menu by pressing the C button twice This returns you to the normal display mode main level 76 disarm 20 17 08 02 troubles setup setup set time setup code intern int code code int 123 code code int 0000 code code setup code intern disarm 20 27 08 02 6 Programming an access code for externally armed You can also program an access code for the state change to externally armed or from externally armed to disarmed This access code is only valid for the buttons on the base station itself not for a remote control and is requested after each button is pressed The state is only changed after you have entered the correct code If switching back and fort
140. utton three times This returns you to the normal display mode main level If you accidentally remove the sensor s batteries without previously setting the base station to the service battery change mode the sensor must also be deleted first and disarm 12 25 05 02 troubles sensors sensors add sensors delete contact 1 livingr w1 contact 4 bedr w1 delete Y 0OK Nic smoke 3 child Dana disarm 12 25 05 02 67 3 Modify a sensor name or assign a sensor name retrospectively Sensor names can of course be modified or assigned at a later stage You must be on the main level The LCD should appear as on the right for example with the time and the date Briefly press the Men a A button on the operating unit of the FAZ 3000 2 alarm base station Use the 4 and buttons to select the sensors menu Confirm your selection by briefly pressing the OK button Use the 4 and buttons to select the sensors name menu Confirm your selection by briefly pressing the OK button The first sensor that was registered with the alarm base station is displayed Use the 4 and Y buttons to select the sensor or the device using the gt button whose name you wish to modify enter for example change the capital D in the name Chi 1D to a small d
141. veral NO contacts they must be connected in parallel figure 21 Do not connect terminating resistors here either RS Please note The KL1 connection for NO contacts is always active irrespective of whether disarmed internally armed or externally armed is set This is ideal if glass break sensors with NO contacts are used An alarm is set off immediately when a pane of glass is smashed Figure 21 The maximum attainable wiring length per alarm loop greatly depends on the cable used and the transmission resistance of the magnet and or glass break sensors Under ideal circum stances 100m or more is possible The wireless range may be reduced when you install the door window detector and magnet on metal doors or windows Asarule the magnet is mounted to the moving part window door panel picture for example and the FAZ 3000 TF 2 door window detector is attached to the static part window frame door frame or wall for example Please observe the recommended distances between the magnet and the door window contact that are illustrated in figure 19 on the previous page Themagnetand the FAZ 3000 TF 2 door window detector can be attached using the enclosed double sided tape You can use suitable screws to mount both components to the surface and thus prevent them from being sabotaged However you should first check that they are working properly so as to avoid drilling any unatt
142. while In order to arm the alarm system all the doors and windows that are fitted with a door window detector should be shut If the magnetic contact of a door window detector is open the base station indicates this by displaying cont open Arming is prevented on the first press of the button on the alarm base station or remote control The same happens when there are other troubles for example ifa sensor or alarm base station s batteries are empty or not inserted Only on the second press of the button regardless of whether intern scharf internally armed or extern scharf externally armed is set is the alarm base station forced to arm despite for example an open magnetic contact It is possible however to close the open magnetic contact or to be more precise the open NC contact whilst the alarm base station is armed at any time and without any problems The alarm is triggered only on re opening e In the event of an alarm it can be stopped immediately by pressing the unscharf disarm button on the base station remote control or optional activation switch The same applies when a trouble occurs for example if the casing of one of the sensors is opened and the sabotage contact is therefore triggered Pressing the unscharf disarm button again deletes the alarm indication on the LCD alarm memory is deleted 58 14 Other functions of the base station Besides the progr