1. cleaning of the O Two Medical Demand Valve Resuscitator should be undertaken to maintain the equipment in a clean condition Face masks patient valve and diaphragm can all be cleaned using a mild soap solution and disinfected using a legally marketed commercially available disinfectant All other components should be cleaned with a mild soap solution WARNING Do not attempt to clean and sterilize any components that are designated as disposable as immersion of these items into a sterilizing solution can cause degeneration of the materials CLEANING PROCEDURE The unit must be thoroughly cleaned after each patient use 1 Operate the manual button to blow out any contaminant from the patient valve 01DV2000 only 2 Ensure that the cylinder is turned off completely clockwise 3 Bleed the remaining pressure out of the system by depressing the manual ventilation button 01DV2000 only CHAPTER 4 SERVICING 4 1 ROUTINE MAINTENANCE WARNING The O Two Medical Demand Valve Resuscitator is designed to provide respiratory support in all emergency situations Failure to follow the maintenance and inspection routine could result in incorrect operation of the resuscitator To ensure proper operation of the resuscitator regular inspection and checking of the resuscitator and accessories for correct function should be undertaken by a responsible member of staff on a regular basis and it is recommended that a service record be ma
2. MANUFACTURERS AND DISTRIBUTORS OF CPR Bio Barrier Face Shields Universal Pocket Ventilators Rescue Breather CPR Protective Barriers Demand Valve Resuscitators CAREvent Range of Automatic Transport Ventilators Oxygen Demand amp BVM Oxygen Supply Refill Valves SQ Unibody Regulators EasyGrip Bag Valve Mask Resuscitators Burn Relief Burn Kits and Dressings Genesis II IDLH Rescue Resuscitators Equinox 50 Nitrous Oxide 50 Oxygen Administration Systems Your Representative is O TWO MEDICAL TECHNOLOGIES INC Innovation in Resuscitation u C 0120 ES 7575 Kimbel Street Ken Mississauga Ontario Canada L5S 108 Tel 905 677 9410 Fax 905 677 2035 Website www otwo com E Mail resuscitation otwo com For your nearest Authorized O Two Medical Tech Distributor In North America Toll Free 1 800 387 3405 O Two al MEDICAL TECHNOLOGIES INC DEMAND VALVE 01DV3000 DEMAND VALVE RESUSCITATOR 01DV2000 USER MANUAL Made in Canada by O Two Medical Technologies Inc Part Number 17MP3136 Rev 6 Sept 2008 O TWO MEDICAL TECHNOLOGIES INC DEMAND VALVE DEMAND VALVE RESUSCITATOR REPLACEMENT PARTS amp ACCESSORIES 17MP9039 17MP1528 02FM4999 01FV4302 01CC8016 01FG6520 Non Rebreathing Valve Cap Silicone Diaphragm Universal Oronasal Resuscitation Mask 6 Replacement Hose with Fittings Softpack Clamshell Carrying Case Head Harness System 12 TABLE OF CONTENTS CHAP
3. TER _ TITLE 1 1 1 1 2 1 3 1 4 3 1 32 4 1 4 2 THE RESUSCITATOR O Two Resuscitation Systems Warranty Information Safety Precautions Performance Specification GAS SUPPLY Gas Supply Connections OPERATING PROCEDURE Manual Resuscitation 01DV2000 only Demand Breathing SERVICING Routine Maintenance Cleaning the O Two Medical Demand Valve Resuscitator PAGE n a N N CHAPTER 1 1 1 0 TWO MEDICAL DEMAND VALVE RESUSCITATOR O Two Medical Technologies oxygen powered Demand Valves and Demand Valve Resuscitators provide trained individuals with a safe and effective means of maintaining artificial ventilation during respiratory arrest or providing a 100 oxygen concentration during periods of respiratory distress O Two Medical Demand Valves and Demand Valve Resuscitators are lightweight portable and extremely durable Designed for the demands of the pre hospital environment they can be operated anywhere an oxygen cylinder or piped wall outlet is present Note Demand Valves and Demand Valve Resuscitators are considered a critical device and their components considered critical components Only those individuals trained in Cardio Pulmonary Resuscitation and operation of oxygen powered resuscitators should use this equipment Thoroughly review the instruction manual before use 1 2 WARRANTY WARRANTY O Two equipment is manufactured from the finest quality materials Each individual part is subject to strict q
4. ap solution Dry all components thoroughly Re assemble and check performance 10 1 3 SAFETY PRECAUTIONS The O Two Medical Demand Valve Resuscitator is designed to provide emergency ventilatory support to victims of respiratory and or cardiac arrest and demand breathing capability or those in respiratory distress The O Two Medical Demand Valve Resuscitator is intended for use by suitably trained and qualified personnel The following precautions should always be observed CAUTION FEDERAL LAW RESTRICTS THIS DEVICE TO SALE BY OR ON THE ORDER OF A PHYSICIAN WHEN THE UNIT IS IN USE DO NOT SMOKE OR USE NEAR OPEN FLAME EITHER DURING RESUSCITATION OR WHEN CHANGING THE CYLINDER WHEN NOT IN USE ALWAYS TURN OFF THE CYLINDER NEVER ALLOW OIL OR GREASE TO COME INTO CONTACT WITH ANY PART OF THE CYLINDER REGULATOR OR RESUSCITATOR DO NOT DISASSEMBLE ANY PART OF THE UNIT EXCEPT WHERE DESCRIBED IN THIS MANUAL AS ANY UNAUTHORIZED DISASSEMBLY WILL INVALIDATE THE WARRANTY 6 AFTER USE ALWAYS ENSURE THAT ALL COMPONENTS ARE CLEANED IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED IN THIS MANUAL 7 ALWAYS USE THE CHECK LIST TO ENSURE THAT ALL COMPONENTS ARE REASSEMBLED CORRECTLY AND THAT ALL ITEMS ARE REPLACED IN THE CARRYING CASE 8 AFTER USE ALWAYS ENSURE THAT A FULL GAS CYLINDER IS ATTACHED BEFORE RETURNING THE UNIT TO ITS NORMAL STORAGE POSITION 4 2 CLEANING THE O TWO MEDICAL DEMAND VALVE RESUSCITATOR Routine
5. intained for each unit This check is to ensure that all of the accessories and resuscitator components are present the oxygen cylinder is full and that the resuscitator is in working order MAINTENANCE Resuscitation parameters should be checked at least every six months and more frequently in high use applications Units with test pressures outside of the ranges listed in the product specifications should not be used O Two Medical products are not designed for field disassembly or service outside that indicated in this manual Any malfunctioning units should be returned to the manufacturer or an Authorized O Two Medical Technologies Dealer Unauthorized repairs will nullify the product warranty 1 4 PERFORMANCE SPECIFICATIONS Manual Flowrate 01DV2000 only 40 LPM Minimum Peak Flow rate 110 LPM 8 cm H O Exhalation Resistance 0 to 6 cmH 0 E 60 LPM Inhalation Resistance 0 to 6 cmH O 60 LPM Input Pressure ne un nee 50 PSI Max Pressure Relief Valve 01DV2000 only 60 cmH 0 Initiation Pressure ccc cece cece eee ees less than 2 cmH O Audible Over Pressure Alarm 01DV2000 only YES Operating Temp s cece eee eeeeee ene ee ene ee en O F to 122 F 18 C to 50 C Storage Temp ie 40 F to 140 F 40 C to 60 C Input Connection 220220essnenenseene rennen 9 16 DISS Patient Connec
6. sure adequate ventilation DEMAND BREATHING The O Two Medical Demand Valve Resuscitator is equipped with a Demand System enabling spontaneously breathing patients to demand oxygen An inspiratory effort by the patient will open the demand valve and oxygen will flow to the patient at a rate in line with their inspiratory effort
7. tor cece cece cence eee eeee eraus 15 22 mm Weisht ns ne gear ga re 8 2 OZ 230 grams Patient Valve Dead Space oooooocccccoconccnconccnccnonenocannns 8 ml Dimensions inches Dia 2 0 x 3 5 Approx mm Dia 52 x 90 Approx CHAPTER 2 GAS SUPPLY 2 1 GAS SUPPLY CONNECTIONS The O Two Medical Demand Valve Resuscitator is designed to operate on either compressed air or medical oxygen from either a cylinder or piped in system The inlet fitting on the O Two Medical Demand Valve Resuscitator is a standard 9 16 DISS female fitting The O Two Medical Demand Valve Resuscitator is designed to operate on an input pressure of 50 psi CHAPTER 3 OPERATING PROCEDURE MANUAL VENTILATION The O Two Medical Demand Valve Resuscitator has been fitted with a Manual Button to allow manual ventilation of the non breathing or respiratory distressed patient By using the manual button the operation of the resuscitator can be easily timed with chest compressions during CPR This will avoid the potential problem of the aspiration of stomach contents due to gastric distension which may occur if overlap of chest compression and ventilation occurs In patients that are intubated this overlap of compression and ventilation may increase cardiac output without the danger of gastric distension WARNING At all times during resuscitation the rise and fall of the patients chest should be monitored to en
8. uality control tests to ensure exceptionally high standards The manufacturer warrants to the purchaser of DEMAND VALVE RESUSCITATOR that its component parts are free from defects in material and workmanship for a period of two years from the date of purchase The manufacturer will replace and or repair all parts of the resuscitator at its option for two years from the date of purchase at no cost to the purchaser upon the notification of the defects in writing by the purchaser All shipping costs shall be borne by the purchaser The manufacturer shall be liable under this warranty only if the resuscitator and its parts have not been used and serviced in the normal manner described in the instruction manual There are no other expressed or implied warranties This warranty gives no specific legal rights You may also have other rights which may vary according to local regulations C Demand Valve Resuscitator Body B Diaphragm A Patient Valve Fig 1 11 Remove the facemask from the unit and then disconnect the unit from the regulator This is accomplished by counter clockwise turning of the connection nut at the regulator end of the hose A wrench may be required Unscrew patient valve a from the unit body being careful to ensure that the diaphragm b is retained fig 1 Wash all components thoroughly in a mild soap solution and disinfect as required The unit c can be wiped over with a soft cloth and mild so
Download Pdf Manuals
Related Search
Related Contents
Bases Administrativas ダウンロード - リビングアメニティ協会 Toshiba BDX1100KU Blu-ray Player User Manual Double Ball DISHWASHER SERVICE MANUAL SDHCメモリーカード 16GB LQ-510X - Product Information Guide Manuel d`utilisation du système de base du traitement des medidor-de-humedad-para-granos-digital-portatil-tipo Copyright © All rights reserved.