Home
USER`S MANUAL - Famedix Healthcare Solutions
Contents
1. EASYMAX SELF MONITORING BLOOD GLUCOSE SYSTEM USER S MANUAL EASYMAX MasterDriver Self Monitoring Blood Glucose System User s Manual Please read this User s Manual thoroughly Before using your blood glucose meter Dear EasyMax MasterDriver SMBG System Owner Thank you for using the EasyMax MasterDriver Self Monitoring Blood Glucose SMBG System We designed this system to be dependable easy to use compact lightweight and Portable to help you monitor your blood glucose on a regular basis Please read this manual thoroughly before you begin testing This manual provides you and your diabetes care team with important information and step by step direction to use the EasyMax MasterDriver Self Monitoring Blood Glucose System Thanks again for choosing the EasyMax MasterDriver System Intended Use The EasyMax MasterDriver Self Monitoring Blood Glucose Test System is intended for the quantitative measurement of glucose in fresh capillary whole blood samples drawn from the fingertips forearm or palm Testing is done outside the body In Vitro diagnostic use It is indicated for use at home over the counter OTC by persons with diabetes or in clinical settings by healthcare professionals as an aid to monitor the effectiveness of diabetes control A Although the EasyMax MasterDriver SMBG System is easy to use you may need to consult your healthcare professional this may be your doctor pharmac
2. Display dimension 1 93 x 0 94 49 x 24 0 mm Device dimension H x W x D mm 3 8 x 1 5 X 0 6 89 0 x 38 0 x 16 5 mm Weight 1 2 oz 34 33 grams w o batteries Principles Electrochemical biosensor technology Embedded Software Auto Run GlucoManager Data Management Software 43 Running with Your Computer 1 Plug the EasyMax MasterDriver meter into a USB port on your PC 2 The display shows PC and the GlucoManager software runs automatically For more information please read GlucoManager Data Management Software GDMS User s Manual A 1 Make sure you had exited from GlucoManager software otherwise DO NOT plug out meter 2 Do not insert strip while meter connect on PC 3 The suggested monitor for the software is 1024 x 768 dpi 44 Limitation The test strips are used for fresh capillary whole blood samples DO NOT use neonate blood sample Extreme humidity may affect the results A relative humidity greater than 90 may cause incorrect results 3 The system should be used at a temperature between 10 C 40 C 50 F 104 F Outside this range the system may get incorrect results DO NOT reuse the test strips The test strips are for single use only 5 Hematocrit The hematocrits between 30 and 55 will not significantly affect the results Hematocrit below 30 may cause higher results Hematocrit above 55 may cause lower results If y
3. between 2 C 30 C 35 6 F 86 F Do not freeze If you would like to purchase EasyMax Control Solutions please contact your local dealer 18 Running a Control Solution Test You need the meter a test strip and control solution 1 Puta test strip into the meter in the direction of the arrow 2 The meter beeps and turns on automatically The icon and JIL shows itself Press Cy to enter the Control Solution mode 8 Place the meter on a flat surface like a table 4 Remove the control solution bottle cap and wipe the tip of the bottle with a tissue 19 5 Squeeze the bottle until tiny drop forms at the tip of the bottle 6 Touch the drop to the Blood collection area at the tip of the test strip Do not put control solution on top of the test strip When you hear beeps you have enough control solution in the test strip 7 The meter starts to count down from 5 seconds the display shows and then shows the test result 8 Do not remove the test strip yet Check if the reading falls within the range printed on the test strip bottle 9 Remove the test strip and throw it away after you have compared the reading to the range printed on the test strip bottle 20 Understanding Control Solution Test Results The label on your test strip bottle shows the acceptable ranges for the Control Solutions The result you get should be inside this range Make sure you compare the result
4. it means What to do Humidified or used strip Not enough blood sample You may have a very high blood glucose level severe hypoglycemia over 630 mg dL 35 mmol L 41 Please replace with a new strip Please discard the test strip and repeat the test Please test again and if you get the same result please contact your healthcare professional immediately What it means What to You may have a very low blood glucose level severe hypoglycemia lower than 20 mgldL 1 11 mmol L Low power The meter is connecting to the computer 42 Please test again and if you get the same result please contact your healthcare professional immediately Please replace with new batteries You can start to use the embedded software Please read GlucoManager Data Management Software GDMS User s Manual for more information Chapter 6 Technical Information Specification Brand name EasyMax MasterDriver Blood Glucose Meter Range 20 630 mg dL 1 11 35 mmol L Test time 5 seconds Run with PC 10000 test results Memory sets embedded Memory 480 test results Operating Temp 10 C 40 C 60 F 104 F condition Relative Humidity RH 90 Blood sample Fresh blood from fingertip forearm or palm Hematocrit Het 30 55 Power CR2032 Lithium Cell 3V 1 piece Battery life 1000 tests
5. the meter memory or if you want to download your results to a computer 4 Insert a new battery the meter beeps and tum on automatically 2 The last 2 digits of the year flash at the center of the display Press C7 to adjust the year and press 3 to confirm the setting Wire 3 Repeat step 2 to set the date and time The flashing field is L the one you are currently setting When finishing the setting the display shows OK and the meter beeps Ltt 15 Using EasyMax Blood Glucose Test Strip Use only with EasyMax MasterDriver Blood Glucose Meter m Run a control solution test every time you open new box of test strips See Chapter 2 Control Solution Testing m Keep the test strips in their original bottle m Close the bottle tightly right away after you take a test strip out This keeps the test strip Use the test strip within three minutes after you take it out of the bottle The strip is for single use only Do not reuse it m Record the date you open the test strip bottle Be sure to check the Expiration date on the test strip bole The test strip is good for three months from the date the bottle is opened or until the expiration date on the bottle whichever comes first Store the test strip bottle and your meter in a cool dry place Store the test strips between 2 C 30 C 35 6 F 86 F Do not freeze Do not apply blood or control solution to the t
6. 2 50 942 084 1 5 mg dL 5 32 3 20 100 mg dl 2 80 12 30 0 89 Blirubin unconjugated 2 4 mg dL 252 4 05 023 Uric acid 8 mg dL 271 955 175 4 mg dL 542 164 EX 46 Device Information EasyMax MasterDriver SMBG System MasterDriver Blood Glucose Test Strips EasyMax Blood Glucose Meter Manufacturer EPS BIO TECHNOLOGY CORP No 8 R amp D RD Il Hsinchu Science Park Hsinchu Taiwan 30077 Website htip www epsbio com Boulevard Boulevard G n ral Wahis 53 B 1030 Brussels Belgium TEL 32 2 732 5954 FAX 32 2 732 6003 E mail mail obelis net PIN 718059100 Rev A02 47 CASYMAX
7. Tabie 10 Diabetes care 2011 Vol 34 Suppl 1 821 Unusual Test Results If your test result doesn t match the way you feel please follow these steps 1 Run a control solution test Chapter 2 Control Solution Testing 2 Repeat a blood glucose test Chapter 3 Testing Your Blood glucose 3 If your test results still don t reflect the way you feel call your doctor immediately A 1 Extremely high humidity may affect the test results A relative humidity greater than 90 may cause inaccurate results 2 A red blood cell count Hematocrit that is either very high above 55 or very low below 30 may not provide accurate results 3 Some studies have shown that electromagnetic fields may affect results Do not test near an operating microwave oven 33 Symptoms of High or Low Blood Glucose Being aware of the symptoms of high or low blood glucose can help you understand your test results and decide what to do if they seem unusual Here are the most common symptoms Greater than 240 mg dL 13 33 mmol L What It Means The test result is higher than reference range 70 110mg dL or 3 89 6 11mmol L Symptom creased appetite or thirst frequent urination blurred vision headache general aching or vomiting etc What to Do W f you are experiencing any of these symptoms test your blood glucose m Ifthe result displayed is greater than 240 mg dL and you have symptoms of high blood glucose contact your hea
8. est number that draws enough blood for a test Try different settings to find the one that s right for you W Please do not share your lancing device with anyone And always use a new sterile lancet Lancets are for one time use only A Used test strips and lancets are considered bio hazardous waste in accordance with local regulations and should be handled as if capable of transmitting infection The users may discuss methods for disposing of used test strips and lancets with their doctor 23 Inserting a Lancet Into The Lancing Device You must first load the lancet into the lancing de to get it ready for use 1 Unscrew the Cap 2 Insert the lancet into the lancing 3 Recap the front cap device firmly then twist off the protective cover 24 S EB 4 Select the desired 5 Pull on the sliding barrel of 6 Set the lancing device aside penetration depth the lancing device until it until later in the test clicks and then release Now the lancing device is ready A Select 1 2 for soft or thin skin 3 for average and 4 5 for thick or calloused skin 25 Running a Blood Glucose Test with Blood from Your Fingertip 1 Wash your hands with soap and warm water Rinse and dry thoroughly 2 Puta test strip into the meter in the direction of the arrow The meter beeps and tums on automatically 3 When the blood drop flashes on t
9. est strip until you insert it into the meter Do not touch the test strip with wet hands Do not bend cut or twist the test strips 16 Chapter 2 Control Solution Testing Why Run a Control Solution Test We recommend that you run the EasyMax Normal control solution test because it lets you know that your meter and test strips are working properly to give you reliable results You should run the control solution test when You use the EasyMax MasterDriver Blood Glucose Meter for the first time You open a new bottle of test strips You think the meter or test strips may be working incorrectly You drop the meter You have repeated a test and the test results are still ower or higher than expected You are practicing the test procedure A Professional users are instructed to follow federal state and local guidelines 17 About the Control Solution Use only with EasyMax test strips m Write the date you opened the bottle on the bottle label The control solution is good for three months from the date the bottle is opened or until the expiration date on the bottle whichever comes first Do not use a control solution that is past the expiration date The control solution can stain clothing If you spill it wash your clothes with soap and water Close the bottle tightly after every use Left over control solution should not be added back into the control bottle Store the bottle of control solution at room temperature
10. ficient 30 Running a Blood Glucose Test with Blood From Your Palm Optional 1 Massage the puncture area of forearm for a few seconds f 2 Press and hold the device with one clear adjustable tip against the palm 3 Press the trigger button to activate the lancing device 4 Hold the device against forearm and increase pressure until the blood sample size is sufficient Note m Check with your healthcare professional before test other sites than fingertip m Please do NOT use the first drop of blood sample Discarding Used Lancets ed 1 Unscrew and remove the cap 2 Without touching the used lancet stick the lancet tip into its protective cover 3 Pointing the lancing device toward a container for sharp or biohazard material slide the ejection button down to release the covered lancet into the container 32 Understanding Your Test Results The EasyMax Blood Glucose test strips are plasma referenced and calibrated for easier comparison to lab results The normal fasting blood glucose range for an adult without diabetes is 70 130 mg dL 3 88 7 22 mmol L Two hours after meals the blood glucose range for an adult without diabetes is less than 120 mg dL 6 66 mmol L For people with diabetes please consult your doctor for the blood glucose range appropriate for you Ratarenoe American Diabetes Associaton Standards of medical care m clabetes
11. he display using the lancing device 4 Hold the lancing device firmly against the side of your finger Press the trigger button Then remove the lancing device from your finger 26 5 Gently squeeze and or massage your fingertip until round drop of blood on your fingertip 6 Touch the blood drop at the tip of the transparent window of the test strip Do not put blood on top of the strip When you hear beeps you have enough control solution in the test strip Be sure to get enough blood in the test strip Otherwise an inaccurate reading may result 7 The meter starts to count down from seconds the display shows Ok and then shows the test result 8 Remove the test strip and the meter turns off automatically 27 Alternate Site Testing Optional Understanding Alternate Site Testing AST What is AST What is the advantage of AST Besides the fingertip you can test the You have the option of testing other places forearm or palm your body besides the fingertip Consult your health care professional before you begin using the forearm or palm for testing Blood glucose test results obtained from your forearm or palm may differ significantly from fingertip samples We strongly recommend that you Do AST ONLY in the following intervals m Inapre meal or fasting state more than 2 hours since the last meal m Two hours or more after taking insulin m Two hours or more af
12. ist or diabetes nurse educator for instructions on how to use the system Only the correct use of the system will ensure accurate results Standard Accessories Your new EasyMax MasterDriver Blood Glucose meter and accessories work together to measure the amount of glucose in your blood The system includes Carrying Case Kit Box Blood Glucose Meter User s Manual Test Strip x 10 ct Quick Reference Guide Lancet x 10 ct Test Strip Instructions Lancing device Warranty Card CR2032 Battery x 1 Optional Accesso AST Cap EasyMax Low Control Solution EasyMax Normal Control Solution EasyMax High Control Solution A EasyMax Control Solutions are available For purchase please contact your local dealer Why is it so important to test blood glucose regularly Testing your blood glucose regularly can make big difference in how you manage your diabetes every day We ve made this SMBG system as simple as possible to help you to use the meter regularly Your meter is easy to use and you can adjust the lancing device for your comfort Do you need Help If you have questions or need assistance please contact your healthcare professional or visit EasyMax Website www easymax us for diabetes management tools and product demonstrations Please complete your warranty card and it so you receive the best customer service possible and news about product update Although the EasyMa
13. lthcare professional instantly If the result does not match how you feel follow the steps under Unusual Test Results 34 Below 60 mg dL 3 33 mmol L What It Means The test result is lower than reference range 70 110mg dL or 3 89 6 11mmol L Symptom Sweating trembling blurred vision rapid heartbeat tingling or numbness around mouth or fingertips et What to Do m If you are experiencing any of these symptoms test your blood glucose m If the result displayed is below 60 mg dL and you have symptoms of low blood glucose contact your healthcare professional instantly m Ifthe result does not match how you feel follow the steps under Unusual Test Results Comparing Your Meter Result to a Lab Result common question is how the blood glucose results on your meter compare to the lab results Your blood glucose can change quickly especially after eating taking medication or exercising If you test yourself in the morning then go to the doctor s office for a blood glucose test The results will probably not match even if you are fasting This is typically not a problem with your meter it just means that time has elapsed and your blood glucose has changed If you want to compare your meter result to the lab result you must be fasting Bring your meter to the doctor s office and test yourself by fingertip within five minutes of having blood drawn from your arm by a healthcare professional Kee
14. m Your Forearm Optional 30 Running a Blood Glucose Test with Blood from Your Palm Optional 31 Discarding Used Lancets n Understanding Your Test Results 33 Unusual Test Results 33 Symptoms of High or Low Blood Glucose 34 Comparing Your Meter Result to a Lab Result 36 Chapter 4 Meter Memory Setup Memory Storing Test Result Viewing amp Deleting Test Results 37 Chapter 5 Maintenance and Troubleshooting Installing Battery Cleaning Your Meter Maintenance and Testing Cleaning Your Lancing Device Screen Messages and Troubleshooting Chapter 6 Technical Information Specifications Running with Your Computer Limitation Device Information 12 Chapter 1 1 Understanding Your Meter EasyMax MasterDriver Blood Glucose Meter Display Front Back Electrod Test Strip Slot Insert test strip here Strip Insert Direction Buttons Turn the meter on or off Select or change information Hand Hold Ara gt Confirmation Window 13 Edge to Apply Sample S ME Installing Battery 1 Open the battery door of the meter by sliping the tab in the direction of the arrow 2 Insert a battery and the meter beeps 3 Put the battery door back in place and snap it closed The meter tums on automatically 14 Setting the and Date First Time Use Setting the current time and date in your meter is important if you intend to use
15. nd go back to the total number of the stored results 5 Press for 1 second to go back to the total number of the stored results 6 Press for 3 seconds to turn off the meter or the meter turns off automatically in 90 seconds 37 Chapter 5 Maintenance and Troubleshooting Installing Battery The meter uses one CR2032 Battery Battery will normally last for more than 1000 tests Other types of CR2032 batteries also acceptable but the capacity of test times may differ Install J the battery when you first use the meter or replace with new L amp battery when the LP low power message and the low battery symbol appear on the display The meter will not turn on the first time the battery is installed Please press and hold button or insert the test strip to tum your meter on The meter will turn off automatically Or you can press and hold 9 button to turn your meter off A 1 The meter won t delete earlier records after you replace the battery 2 You should reset the time and date again after you replace the battery 3 CR2032 x 1 battery are available at most stores You may take the old battery with you for replacement 4 Remove the battery when you will not be using the meter for one month or more 38 Cleaning Your Meter Caring for your EasyMax MasterDriver system does not require special cleaning Please keep the meter free of dirt dust bloodstain and
16. or use Caution Batch code A Do not re use In vitro diagnostic medical device IV CR2032 x 1 battery only e Use by 4 Temperature limitation Manufacturer REF Catalogue number Serial number CONTROL Control z Authorized representative in Ae Sultan for ECIREP the European Community This product meets the requirements of Directive 98 79 EC in vitro diagnostic medical devices ee Go 969060 BBB JL BBE Result amount Blood apply Inserta test strip unit Date 08 90 E e fa Time Button Memory Button Battery A The unit of Blood Glucose Meter is set at mg dL Table of Contents Chapter 1 Understanding Your Meter The EasyMax MasterDriver Blood Glucose Meter 13 Installing Battery 14 Setting the Time and Date First Time Use 45 Using Blood Glucose Test Strip 16 Chapter 2 Control Solution Test Why Run a Control Solution Test ned About the Control Solutions 18 Running a Control Solution Test 19 Understanding Control Solution Test Results 2 Chapter 3 Testing Your Blood Glucose Using the Lancing Device Inserting a Lancet into the Lancing Device 24 Running a Blood Glucose Test with Blood from Your Fingertip 2 Alternate Site Testing Optional 28 Running a Blood Glucose Test with Blood fro
17. ou do not know your hematocrit level please consult with your healthcare professional 6 Up to the altitude of 3 048 meters has effect on readings Healthcare Professionals Please note these additional Limitations 7 Patients undergoing oxygen therapy may have inaccurate results 8 If the patient has the following conditions the result may fail Severe dehydration Severe hypotension low blood pressure Shock 45 state of hypoglycemic hyperosmolar state with or without ketosis 9 Lipemic samples Cholesterol level up to 500 mg dL 12 932 mmol L and triglycerides up to 1 000 mg dL 11 301 mmol L do not affect the results Grossly lipemic patient samples have not been tested and are not recommended for testing with EasyMax MasterDriver Glucose Meter 10 Critically ill patients should not be tested with home use blood glucose meters 11 DO NOT use serum or plasma sample for EasyMax MasterDriver SMBG System 12 DO NOT use anticoagulant NaF or potassium oxalate for venous sample preparation 13 Interfering Substances depend on the concentration The below substances up to the test concentration will not affect the test results Bis 8100059 Level somgaL sampat Concentrations of the interference Ascorbic Acid 4 mgl 108925 175 1555 Ibuprofen 50 mg dL 3 10 2 88 462 L Dopa 1 8 mg dl 10 5996 791 450 Sodium Salicylate 50 malat
18. p in mind that the lab could use different technology than EasyMax Master Driver blood glucose meter and that blood glucose meters for self testing generally read somewhat lower or higher than the lab result For accuracy and precision data and for important information on limitations see the instructions that come with your test strips 35 Chapter 4 Meter Memory Setup Memory Storing Test Results Your meter stores a maximum of 480 test results with the time and date of the test You can review them at any time When the memory is full the oldest result is dropped as the newest is added so it is very important to have the correct time and date set in the meter A 4 Do not change your therapy based on one individual result in memory 2 The memory is not lost when you replace the battery You do need to check that the time and date are still correct See Section Setting the time and date in Chapter 1 3 Once 480 results are in memory adding a new result causes the oldest one to deleted 36 Viewing amp Deleting Test Results 1 Press 6 to turn the meter on 2 Press 7 to enter memory mode The meter shows the total number of the stored results first and then shows the latest result 3 Press C to view the test result from latest to oldest 4 To delete a test result press C7 for 3 seconds When display shows dEL press 3o confirm the deletion Or press CF to cancel the deletion a
19. t be used for one month or more Waring for potential biohazard Healthcare professionals using this system on multiple patients should be aware that all products or objects that come in contact with human blood even after cleaning should be handled as if capable of transmitting viral disease 6 Consult with your healthcare professional before testing on your forearm or palm Do not touch the strips with wet hands Do not use expired strips the expiration date is shown on the bottle Do not bend cut or twist the strips Up to the altitude of 3 048 meters has effect on readings Health Related Information Ifyou are very dehydrated urinating frequently low blood pressure shock or hyperosmolar hyperglycemic nonketotic coma HHNKC you may get a test result that is lower than what your blood glucose really is If you think you are dehydrated call your doctor right away Ifyou have followed the steps in the user s manual but still have symptoms that don t seem to match your test results or if you have questions please talk to your doctor Please read your test strip instructions carefully for additional health related information A Warning for potential biohazard Healthcare professionals using this system on multiple patients should handle all products or objects in contact with human blood carefully to avoid transmitting viral disease even after cleaning Explanation of Symbols Consult instructions f
20. ter exercise Do NOT use AST i You think your blood glucose is low You are unaware of hypoglycemia Your AST results do not match the way you feel You are testing for hyperglycemia Your routine glucose results are often fluctuating f you are pregnant Fingertip test only If sick If blood glucose is low If blood glucose is low After exercising Two hours or less after eating When you have just taken insulin After injecting rapid acting insulin two hours or less Ifthe blood glucose test result does not match how you feel do a fingertip test to confirm the result again If you often do not notice when your blood glucose is low do a fingertip test A Talk with your healthcare professional before you test forearm NOT ignore symptoms of high or low blood glucose Fingertip samples are able to show the rapid change of glucose faster than forearm samples Do NOT change your treatment just because of a result 29 Running a Blood Glucose Test with Blood From Your Forearm Optional Please use the clear cap with the lancing device for AST testing kae pes 1 Massage the puncture area of palm or forearm for a few seconds p 2 Press and hold the device with clear adjustable A tip against the palm or forearm 3 Press the trigger button to activate the lancing device Hold the device against forearm and increase pressure until the blood sample size is suf
21. to the correct level of control When the control solution result is inside the range on the test strip bottle your test strips and your meter are working properly If your control solution result is not inside the acceptable range printed on your test strip bottle here are some things you can do to salve the problem A Control Solution values will not be included in the memory and averages 21 lt Troubleshooting Checks Was the test strip exposed to open air for a long period of time Was the test strip bottle capped tightly Was the meter functioning well Is the control solution expired contaminated Were test strips and control solutions stored in cool dry places Did you follow the testing steps properly 22 Action If yes repeat the control test with properly stored strips If no this will humidify strips inside Replace the test strips You can use control solution to verify the meter s functions Chapter 2 If yes replace with new control solution to check the performance of SMBG system If no repeat the control test with properly stored strips or control solutions Read Chapter 2 Control Solution Testing and test again Stop using the meter if you continue to obtain the inaccurate results If you have questions or need assistance please contact your healthcare professional Chapter 3 Testing Your Blood Glucose Using the Lancing Device 8 The best depth setting is the low
22. water stains Follow these guidelines carefully to help you get the best performance possible Do Do Not Make sure the meter is turned off Get any moisture in the test strip slot m Gently wipe the meter s surface with a 8 Spray any cleaning solution directly onto soft cloth slightly dampened the meter 8 Put the meter under water or liquid M Pour liquid into the meter 39 Maintenance and Testing Tag Your meter needs no maintenance with normal t use It automatically tests its own systems every time L Li 88 88 you turn it on and lets you know if something is wrong 2 See Screen Messages and what to do about them LI X Lt To make sure the display is working properly tum off the mmgl at meter Press and hold to see the complete display All the indicators should be clear and look exactly like the picture to the left If not please contact your healthcare professional Cleaning Your Lancing Device m clean the lancing device wipe it with a soft cloth dampened with water and mild detergent DO NOT places the entire device under water To disinfect the cap after cleaning place it in 70 75 rubbing alcohol for 10 minutes at least once a week Allow the cap to air dry after disinfecting 40 Screen Messages and Troubleshooting Never make treatment decisions based on an error message If you have any concerns please contact your local dealer What
23. x MasterDriver SMBG System is easy to use you may need to consult with your healthcare professional this may be your doctor pharmacist or diabetes nurse educator for instructions on how to use the system Only the correct use of the system will ensure accurate results 5 Important Information about Your New EasyMax MasterDriver EasyMax MasterDriver blood glucose meter is designed and approved for testing fresh capillary blood from fingertip forearm or palm The meter is for outside the body in vitro use It should not be used to diagnose diabetes EasyMax MasterDriver blood glucose meter can only be used with EasyMax Blood Glucose Test Strips Other test strips will give inaccurate results Testing is not valid for neonatal blood specimen Do not disassemble the meter as this may cause damage to the components resulting in incorrect reading Disassembling the meter will also void the warranty Always keep the meter clean and store it in a safe place Protect the meter from direct sunlight to ensure a longer lifespan You should not store the meter and test strips in a car or a bathroom Keep the meter test strips and lancing device away from children and pets You should not test critically ill patients with home use blood glucose meters Incorrect results may occur when performing the test If you believe you are not feeling well please contact your healthcare professional Remove batteries if the meter will no
Download Pdf Manuals
Related Search
Related Contents
1000 DI-8シリーズ アナログメガ 取扱説明書 State Industries SDV100-199 User's Manual SYNO.API.Auth Manuale di installazione Motori integrati sincroni User manual Page 1 Leggere il presente manuale di istruzioni prima di usare la TROOPER B150 D3 - CD Copyright © All rights reserved.
Failed to retrieve file