Home
        PTZCON manual
         Contents
1.  perimeter scan        Adjust camera focus       Adjust camera zoom       2  D       Close open camera iris  for non auto iris cameras        Menu Esc button for navigating setup menu  amp  key lock    Ot        Show protocol and baud rate for current PTZ ID       es          Keyboard Functions    PLEASE NOTE   Availability of some features will depend on compatibility and specification of your PTZ  camera  Some controller functions may not be supported by your PTZ camera  please  check with the product manufacturer     Function Function Camera  set keys recall keys control keys       Menu setup keys    MENU SETUP KEYS    Menu  Hold for 3s to enter setup configuration menu      2  Enter password  default 8888  See page 5 for further details        Back  Escape to previous menu exit menu        Press once during normal operation to lock keys  will not work in menu    ae Show protocol and baud rate  for current PTZ ID     FUNCTION SET KEYS   preset   To store a preset camera position   press  0 255   Preset     rater To record a predefined movement pattern  press for 3s  All camera movements will  be recorded exactly as per user input  Press again to stop recording    To set up a patrol points at preset camera positions  presets must be defined first   see Preset button      Press  Patrol   choose the first preset position  0 255  then push joystick  downwards to choose dwell time  0 255  then push joystick downwards to select  movement speed  0 99   and push the joystick downw
2. PTZLCON    PAN  TILT AND ZOOM CONTROLLER       USER MANUAL    www espuk com    Product Overview    FEATURES  e Supports up to 255 PTZ cameras  e Multiple protocols and baud rates supported across multiple PTZ cameras  e LCD display  e Control lock feature to deny unauthorised use  e Supports Pelco D  Pelco P  Samsung  Panasonic and HikVision protocols  e Supports baud rates 1200  2400  4800  9600  19200    INSTALLATION OVERVIEW    RS 485 Input Output  Transmit Receive LED  Power LED    RS485 8XPORT T R PW    pifefafs s  dr le    Ta   To  Ra  Rb  G        oo       Installation    It is highly recommended that a screened cable  is used to connect the RS485 control wires et  from PTZ controller  or interference may occur     1  Connect Ta to the RS485  on the PTZ camera s    2  Connect Tb to the RS485  on the PTZ camera s    3  Connect GND to the ground on the PTZ camera s  if applicable  4  Connect the cable screen to GND   5  Set camera protocol s  and baud rate s     RS 485 EXPORT       KEYBOARD OVERVIEW   s  Function  Define a preset camera position          Record new movement pattern  will directly mimic user input     Set up a patrol route based on preset camera positions   positions must be defined by the user     Turn auxiliary PTZ controllers on or off    Patrol    wW  c        o   gt           Select PTZ camera ID   select a PTZ ID to control the associated camera     Recall preset position          Recall pattern       Recall patrol       Set camera to auto pan mode 
3. ards to setup the next point  in the patrol     Once all points in the patrol have been set  press  Patrol          FUNCTION RECALL KEYS    To recall a specific preset camera position  press  0 255     Shot     Press to run recorded pattern   To recall a specific patrol tour  press  0 255   Patrol     Configuration menu    To enter menu press  E  for 1s then enter password  default 8888   Use the joystick up down to navigate through menu tree   Use the joystick left right to alter the current value where applicable  Press to confirm select  press  Sto escape go back    SYSTEM SETUP             ADDRESS             PTZ SETUP    Menu Item Explanation                SET PW Set 4 digit PIN to lock keypad   DEFAULT Restore factory default settings   SOUND SET Key tones on off   ID SET Set keyboard ID  when using multiple controllers   LOCK SET Toggle key lock on off   ADDRESS Sets protocol and baud rate for each PTZ camera     Push joystick left right to select camera ID then press  Push joystick up down to change between protocol baud rates   push joystick left right to alter values  Press to confirm           Key Lock Function    Key lock must be enabled from the menu  see page 5    Key lock can only be engaged if not in setup menu    Press    then enter password PIN to lock keyboard  Repeat process to unlock   To reset a lost password  please call ESP Technical Support on 01527 51 51 50     Warnings   Do not disassemble product  warranty will become void   Only for use indoors i
4. n environments  lt 95  humidity  Only use the supplied 12V PSU          Technical Specifications                   Protocol Pelco P  Pelco D  Panasonic  HikVision   Samsung  RULE  Dahua  SAE   Baud rate  bps  1200  2400  4800  9600  19200   Max camera support 255   Controllers supported 16 in total  15 auxiliary    Power supply DC 12V 10        Power consumption 6W MAX  Working temperature 0  C 50  C  Dimension 420 x 260 x 170mm          Elite Security Products Telephone  01527 515150  Unit 7  Target Park  Shawbank Rd Fax 01527 5151 43  Lakeside  Redditch B98 8YN email  info espuk com    www espuk com       
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Troubleshooting  取扱説明書  Installationsanleitung Französisch  MPR500 Motor Protection Relay User`s Guide    各種機器のデータを正確に一元管理し、リスクの低減を提案    20100104120252 - envoi 2009 catalogue_MFSC VP  かんたん操作ガイド      Copyright © All rights reserved. 
   Failed to retrieve file