Home

LYNX Touch Series Security Systems

image

Contents

1. A e f Base Command is set Off some At the Device Management screen select Advanced Tools tiemiostatswill enter Setback mode Enter the Master User Code on the displayed keypad To turn all lights On select Base Command Set On OR to turn all lights Off select Base Command Set Off Press the Home key to return to the Dashboard screen or select the 9 button to return to the previous screen Controlling Z Wave Devices Scenes are used to control a single or group of devices together turning them OFF ON ON to a preset lighting level temperature or mode or lock unlocked The LYNX Touch has 20 Scenes which may each be configured with up to 10 devices each Scenes can be manually activated or activated by a Rule or Schedule Rules are used to control Scenes by pre set Conditions and Triggers Up to 20 Rules may be programmed locally into the LYNX Touch To program Scenes and Rules refer to the LYNX Touch User Manual Devices can also be activated manually To active devices manually perform the following ACTION NOTES At the Dashboard screen select the Automation icon e The control screens vary according to the At the Automation Screen select the type of device that you wish to features of the specific ZWave device that is edit i e Switches Thermostats or Locks as applicable e T Select the device that you wish to control from the displayed list controlled vary by m
2. Honeywell LYNX Touch Series Security Systems Home Automation Guide a l 800 11309 3 12 Rev A Home Automation Z Wave Programming The LYNX Touch control features Z Wave technology that is designed to automate devices in a home control network The control allows you to easily add and control multiple devices with the press of a button Check with your installer to see if this feature is available Your control and every Z Wave device you add are linked together into a wireless network Each device in your network has a unique address assigned to it and cannot be activated by your neighbor s Z Wave controller The Z wave network supports multiple controllers allowing additional Z wave remotes to be used throughout the home Management of Z Wave devices also known as nodes includes two main operations inclusion exclusion and association or controlling Refer to the Controlling Z Wave Devices section for information regarding association This section describes how to Include add devices into your home control network edit devices and Exclude delete devices Automation and Z Wave functions are accessed via the LYNX Touch Automation icon Z Wave Device Management and Z Wave Advanced Tools screens A list of compatible Z Wave devices can be found in the Z Wave Compatibility Chart contained in this document The devices can be controlled from the LYNX Touch control or the Mobile Internet Device
3. MID or tablet Check with your Installer to see which features are available with your system Refer to the Z Wave Glossary for additional information regarding term and functions Ready To Arm Ready To Arm 12 35 October 26 2011 N f v n b Security gt u 108 S Feels Like 71 F 5 Day Forecast Automation Notices Mostly Sunny Automation ENSE Arm Away Arm Stay Message M 10 18 AM June 8 2010 LYNX Touch Dashboard Screen LYNX Touch Security Home Screen Total Connect Remote Services Enabled N Automation is intended for lifestyle convenience It should not be used for life safety or property protection U L Z Wave automation functionality is supplementary only and has not been evaluated by UL Ready To Arm Switches Provides access to the Switches Grouping Screen Provides access to the Rules Screen Rules are used to Rules automate Z Wave devices based on specified Zone Activity Alarm Status or Alarm Conditions a Switches 468 Thermostat az Schedules Scenes Thermostat Provides access to the Thermostats Grouping Screen Provides access to the Schedules Screen Schedules are Schedules used to activate Scenes based on a specified time and repeat frequency Locks Provides access to the Locks Grouping Screen Provides access to the Scenes Screen Scenes are used to control a single or group of devices together turning them Off On on to a preset
4. in zone programming You must program both Zones for each respective thermostat i e Zone 80 amp 81 for thermostat 1 Zone 82 amp 83 for thermostat 2 and Zone 84 amp 85 for thermostat 3 Home Automation View Edit and Delete Z Wave Devices View Enrolled Z Wave Devices or Controllers To View a list of the enrolled devices perform the following ACTION NOTES At the Dashboard screen select the Automation icon At the Automation Screen select Tools At the Device Management screen select Advanced Tools Enter the Master User Code on the displayed keypad At the Advanced Tools Screen select View Enrolled Devices OR View Enrolled Controllers Use the down Y arrow to scroll to the next page of options Use the A arrow to return to the previous page Press the Home key to return to the Dashboard screen or select the 9 button to return to the previous screen Edit Z Wave Device Names To Edit a device name perform the following At the Dashboard screen select the Automation icon At the Automation Screen select the type of device that you wish to edit i e Switches Thermostats or Locks as applicable Select the device that you wish to edit from the displayed list Select the edit button Enter the desired information limited to 14 characters on the displayed keypad and then select Done The system returns to the previous screen Select Back to r
5. the devices individually therefore each device will need to be Excluded before being Included into a controller At the Device Management screen select Advanced Tools Enter the Master User Code on the displayed keypad Select Reset Controller The panel displays This will delete all nodes and generate a new home ID Select Yes The panel displays All nodes deleted and new home ID generated Select OK The system returns to the previous screen Shift Primary Control After all Z Wave devices have been Included into the Primary Controller control can be shifted to a Secondary Controller To shift primary control to the secondary Z Wave controller perform the following ACTION NOTES At the Dashboard screen select the Automation icon At the Automation Screen select Tools At the Device Management screen select Advanced Tools Enter the Master User Code on the displayed keypad Select Pri Controller Shift to Secondary The panel displays Shifting Put the controller you are shifting to in learn mode Refer to the documentation provided with the controller for additional information Turn On Off all lights To turn all lights On or Off perform the following ACTION NOTES At the Dashboard screen select the Automation icon e If Base Command is set On some g thermostats will exit Setback mode At the Automation Screen select Tools
6. Advanced Tools Screen Shiftto i e a Z Wave remote control and duplicates the Z Wave Secondary network Enable Arm Stay Arm Away or Arm without Auto Stay when 2 Z Wave door lock is locked Causes the system to arm in the selected mode Away Stay or Away without Auto Stay when the Z Wave Door is Locked pere error error error rr error eee eee rr rr rr rr rr rr rr rr rr rr rr rr rr rr rr rr rr rr rr rr rr rr rr rr rr rr rr r rr rr rr r rr rr rr rr ren Includes the panel as secondary controller usually on a Z Wave remote control and duplicates the Z Wave network Devices switches and thermostats only may be Included using the Z Wave remote control and the information can be transferred to the control panel using this feature The secondary controller control panel cannot have Z Wave devices Included The Learn button is selected after Include process is started on the primary controller Required test command to turn On all switches _SetOn Note Some thermostats will exit Setback mode Base Command 2 Required test command to turn Off all switches Set Off Note Some thermostats will enter Setback mode Although both controllers can operate the Z Wave devices only the Primary can Include Exclude devices Including Z Wave Devices The functions described below should be accomplished at the LYNX Touch control Z Wave devices should be in their final location prior to incl
7. ant loss of range approximately 20 since the metal box blocks a large part of the RF signal WARNING NOT FOR USE WITH MEDICAL OR LIFE SUPPORT EQUIPMENT Z Wave enabled devices should never be used to supply power to or control the On Off status or medical and or life support equipment Additional Z Wave Information 1 Once the system has reached node number 232 the system will not allow devices to be enrolled Reset Controller needs to be performed to allow the system to enroll Z wave devices The node numbers can be viewed by selecting Automation Tools Advanced Tools View Enrolled Devices 2 The system is not aware of door locks being enabled with any temporary user shutdown feature such as Vacation Mode The system will continue to unlock a door if programmed to do so via Rules Schedules and Scenes 3 Certain door lock models with thumbturns will provide a brief time window for you to turn the thumbturn before they automatically lock on their own These types of door locks are not recommended for use in conjunction with Z Wave rules schedules and scenes SS 17 Z Wave devices are identified by the Z Wave logo and can be purchased from your local retailer Z Wave is a registered trademark Sigma Designs Inc and or its subsidiaries 2 Corporate Center Drive Suite 100 NNNM Ml oney welt eco soo une Copyright 2012 Honeywell International Inc 800 11309 3 12 Rev A www honeywell com security
8. anufacturer and you will Refer to the figures below for typical examples of the features that can need to review the user manual that was be controlled manually for the devices provided to determine capabilities of each device Home Automation Ready To Arm Ready To Arm Den Lamp Den Lamp ON 10 ON 5100 100 015 VO 5100 100 016 VO Light Control Screen Without Dimming Support Light Control Screen With Dimming Support de Fan AUTO 5100 100 017 VO 5100 100 018 VO Thermostat Control Screen Dual Setback Thermostat Control Screen Front Door Unlocked 5100 100 020 VO Lock Control Screen Z Wave Glossary Controller The Primary Controller is the main device used to set up and control your Z Wave network There can only be one primary controller and it must be used to add or delete devices A primary controller can be a portable device like a hand held remote a static controller permanently installed and never moved a Z wave enabled PC or a Z Wave enabled Ethernet router bridge A Secondary controller can not be used to add or delete devices If the secondary controller is the same brand and model as the primary it will have all of the same capabilities as the primary but can not be used to add or delete devices Event An event is something you want to happen at a specific time and day This could be every day a specific day of the week Monday through Friday Saturday and Sunday only o
9. at Press System on the ZW STAT Press and Hold the 4 or center button on the bottom row of the ZW STAT Press the first down arrow Y to change display to rf10 Press the right last up arrow A to Include the ZW STAT Refer to the Installation Instructions provided with the thermostat for Z Wave inclusion To complete inclusion press Done Press Done on the thermostat to return to normal operation After successfully including a thermostat the device s information will be added to the top of the inclusion list Once you have finished including devices press the Home key to return to the Dashboard screen or select the 5 button to return to the previous screen If you are installing another brand of thermostat folow the instructions provided with your specific device to Include properly When using Z wave thermostat control on the LYNX Touch the scheduling feature within thermostat should not be used When the HOLD button on the LYNX Touch Thermostat control screen is highlighted Z wave scenes driven by rules or schedules will not affect the thermostat operation Additionally if your system is connected to TotalConnect Service the remote 7 day schedules will also not affect the thermostat operation For threshold monitoring to be configurable on the Total Connect Remote Services LYNX TOUCH Z wave thermostat screen the respective zones will first need to be assigned with a response type
10. eturn to the Automation Screen or Press the Home key to return to the Dashboard screen Exclude Delete a Z Wave Device To Exclude a Z Wave device perform the following ACTION NOTES At the Dashboard screen select the Automation icon e Excluding a device sends a command to the At the Automation Screen select Tools Node erasing any previous network At the Device M P lect Exclude Devi 5 information that was learned into it cocos zero ab MEE e Previously deleted devices but not Excluded The panel displays Ready to Exclude device Press the function button will still need to be Excluded before they can on device Within one minute press the device s Function button or be re Included into a controller activate the switch If the module has been successfully Excluded the Excluded device s information will be added to the excluded list If a device which is not known to the panel is excluded Unknown Device Excluded will be added to the excluded list Once you have finished excluding devices press the Home key to return to the Dashboard screen or select the gt button to return to the orevious screen Home Automation Remove Delete all Z Wave Devices Reset Controller To Remove all Z Wave devices perform the following ACTION NOTES At the Dashboard screen select the Automation icon e Resetting the Controller does not Exclude At the Automation Screen select Tools
11. in Stay mode and activating output Z Wave devices via Scenes Home Automation Z Wave Compatibility Z Wave devices may vary follow the instructions provided with the specific device when including and excluding devices into the Z Wave network Refer to the list to view the compatible devices Note Not all Z wave devices have been tested and some features may produce unpredictable results Important Notes Wireless Range This device complies with the Z Wave standard of open air line of sight transmission distances of 100 feet Actual performance in a home depends on the number of walls between the controller and the destination device the type of construction and the number of Z Wave enabled devices installed in the control network Please Note Z Wave home control networks are designed to work properly alongside wireless security sensors Wi Fi Bluetooth and other wireless devices Some 900MHz wireless devices such as baby cams wireless video devices and older cordless phones may cause interference and limit Z Wave functionality Things to consider regarding RF range e Each wall or obstacle such as refrigerator big screen TV etc between the remote and the destination device will reduce the maximum range of 100 feet by approximately 25 30 e Brick tile or concrete walls block more of the RF signal than walls made of wooden studs and drywall e Wall mounted Z Wave devices installed in metal junction boxes will suffer a signific
12. lighting level temperature or mode or locked unlocked Up to 20 scenes can be programmed Tools Provides access to the Z Wave Device Management Screen 5100 100 007 VO LYNX Touch Automation Screen Scenes Ready To Arm Include Devices Exclude Devices Include Devices Enroll Z Wave Modules a eee Check INGDNOHS Check Network Perform system check of Z Wave network Advanced Tools Provides access to additional Z Wave options Advanced Tools Warning automation can only be used for life style enhancement It must not be used for personal safety or property protection 5100 100 074 VO Z Wave Device Management Screen Home Automation Ready To Arm Chime View Enrolled View Enrolled View Enrolled View Z Wave device information System Index name Devices Controllers o h Devices mi device type device ID manufacturer node number i Pri Controller Shift View Enrolled i View Controller Information Controller role Primary or Reset Controller p S econdary Controllers Secondary Home ID device type device ID node number s NAN A A nn Locking Door ee i Deletes all nodes and generates a new random Home ID Resetting the Controller does not Exclude the individual devices therefore each device will need to be Excluded Base Command Base Command Set On Set Off dd Pl Pri Controller Transfers the role of primary controller to another controller Z WaveB
13. programming that user code into the door lock User Codes must be 4 digits When programming user codes into the panel determine if the user code will have access to the Z Wave lock If so the user code will be transferred to the lock Door lock devices may vary follow the instructions provided with your specific door lock to Include properly and to program a new user code If locks will be associated with a Scene the lock s autolock feature must be disabled Due to Low Power Inclusion Mode of secure devices Include the Z Wave Lock first if not using an Inclusion Tool Remote Control The lock should be installed before including other devices Include Add a Honeywell Thermostat Install a Honeywell Thermostat according to the manufactures instructions Device should be mounted in the final location and tested before adding it to the system To Include a Honeywell Thermostat into a Z Wave network perform the following Note Some thermostats do not update temperature status automatically i e Wayne Dalton IMPORTANT Honeywell is not responsible for property damages due to improper setting of the thermostat modes ACTION NOTES At the Dashboard screen select the Automation icon At the Automation Screen screen select Tools At the Device Management screen select Include Devices The panel displays Ready to include device Press the function button on device Within one minute Include the Z Wave thermost
14. r a one time occurrence Events can be set up to control an individual device a group or a scene Exclude When a device is excluded it is removed from the LYNX Touch system Excluding the device also removes the network pairing from the device s memory Important Note A device must be excluded before it can be moved to another network or re included after a controller reset Include Including a device pairs it with the LYNX Touch so that the two can communicate It is also referred to as Adding Node Node is the technical term used to describe a Z Wave device in your home control network Please note that the terms Node Device and Light all refer to an individual Z Wave enabled device and are interchangeable within the context of these instructions Rules Rules are used to automatically perform specified functions in response to certain events which trigger scenes Scene A scene lets you control multiple functions automatically For example you can establish preset brightness levels for multiple Z wave controlled lights and then control them with one command This is ideal for mood or task lighting Scene 1 could be the family room lights set to dim for watching TV Scene 2 could have the same lights set to a different brightness level for other activities like reading or entertaining Schedules The Schedules Feature can be used to program the system to automatically perform certain functions i e automatically arming the system
15. ted and for security purposes enroll at a low power transmission range approximately 6 feet This may require enrolling the lock before it is installed in the door Assemble the Z Wave door lock if required install batteries and connect necessary cables refer to the Door Lock s Instruction Guide Enroll the door lock adjacent to the control within 6 feet and mount within the proper Z Wave range refer to the Important Notes section for further information To Include a door lock into a Z Wave network perform the following ACTION NOTES At the Dashboard screen or Security Home Screen select the Program the user code in the control panel Automation icon At the Automation Screen select Tools At the Device Management screen select Include Devices The panel displays Ready to include device Press the function button on device Within one minute press the device s Function button or activate in accordance with the manufacturer s instructions If the module has been successfully enrolled the panel displays Device Found Please Wait and then the device information is displayed After successfully including a lock the device s information will be added to the top of the inclusion list To include next device press the include button Once you have finished including devices press the Home key to return to the Dashboard screen or select the D button to return to the previous screen prior to
16. usion When Including a device it may be necessary to perform an Exclude before a successful Include can be achieved This is particularly true if the device was previously in another Z Wave network Include Add a Light Switch or Outlet Module Install the receptacle wall switch or lamp appliance module refer to the Module s Instruction Guide To Include a Light switch or outlet module into a Z Wave network perform the following ACTION NOTES At the Dashboard screen or Security Home Screen select the Z Wave light modules may vary follow the Automation icon instructions provided with your specific device j to Incl ly At the Automation Screen select Tools o Include properly At the Device Management screen select Include Devices The panel displays Ready to include device Press the function button on device Within one minute press the device s Function button or activate the switch If the module has been successfully enrolled the panel displays Device Found Please Wait and then the device information is displayed After successfully including a light switch or outlet module the device s information will be added to the top of the inclusion list Once you have finished including devices press the Home key to return to the Dashboard screen or select the D button to return to the previous screen Home Automation Include Add a Door Lock f Z Wave door locks are encryp