1. A36 cabling 8x line out recording PA IRX RG58 IRad HLN82B N HERE 3 Bi Application 1 This diagram shows a complete application for a seven channel OR 6 interpreter system Monitoring part is the Receiver IRX together with the IR Radiator IRad or HLN82B INFRACOM System Components e MSI8D Compact Transmitter e DOL7 2 Interpreter console for 2 interpreters 7 channels e Rad HLN82B High Power Radiator e IRX Receiver for up to 32 channels 19 MO INFRAQOM The next diagram Application 2 shows the extension to a 16 channel system IR Transmitter 8x analog in r 16x line out 8x analog in recording PA _ HLN82B Application 2 Two of the Compact Transmitters MSI8D are linked to one system The monitoring part consists of the Receiver IRX together with the IR Radiator IRad or HLN82B INFRACOM System Components e MSI8D Compact Transmitter e Rad HLN82B High Power Radiator e IRX Receiver for up to 32 channels 20 INFRAQOM MO Troubleshooting Error description Error solution Switching on the system produces no POWER ON condition green LAMP does not light up Error cause The main cable connector is not properly connected to the corresponding socket of the unit Connection cable defective possibly The power switch is not in the correct position C
2. avoid level change between floor sound and interpreter sound This is done by feed in a test signal to socket OR IN and listening to the corresponding sound level Other controls are not necessary for a successful event 14 INFRAQOM MO 6 OPERATION Once the INFRACOM system has been properly started up and checked there is usually no need for any further intervention from the operator Any switching involving the interpreter s microphones and or the language channels is done directly at the interpreter console DOL7 Most of the work involved with audio distribution should have been completed during the preselection of channels and system start up Some features in conjunction with the interpreter console are e Outgoing channel During the actual event the toggle key can be used to move from one preselected console channel A B or C to the other e Incoming channel monitoring For audio input the toggle switch is used to swap from the floor channel to the preselected relay channel and back again e The interpreter s microphone is operating with the microphone button A lamp integrated in the switch indicates when its microphone is active e f ever a microphone needs to be deactivated only briefly this is done by pressing the interrupt key For as long as this key is pressed and held no audio signal is fed onto the interpretation channel If a microphone is turned off with the microphone key then the floor
3. a term often used is delegate can use the microphone system to speak and what he or she says will be translated simultaneously so that other delegates will be able to listen to it in one of the languages This technique permits direct communication in several languages even at very large scale events It is a simple matter to set up the INFRACOM system in such a way that it is protected against eaves dropping from outside Since all information is transmitted in the form of light waves it is possible to use opaque material as necessary to limit the area to which it is to be transmitted Dark curtains drawn across windows for instance are enough to shield a room reliably from the outside world Although the INFRACOM system is most commonly used in combination with an interpretation system and microphone management system it is also possible to use it for other purposes During organized events for instance it is possible to use infrared light to transmit information to indi vidual participants wearing receivers without disturbing anyone else present Another example might be museums applications There it is possible to provide information on individual exhibits by means of infrared light radiated only to a limited area in front of the particular exhibit Visitors listen to the information with receivers and headphones MO INFRAQOM These particular operating instructions deal with the combination of INFRACOM systems and DOL7
4. unit is not proper installed to this user manual it may causes radio interferences Any changes or modifications not explicit approved in this manual could void your authority to operate this equipment 2 2 For customers in the United Kingdom The wires in the main lead are coloured in accordance to the following codes Green and yellow Earth Blue Neutral Brown Live If the colours of the wires in the mains lead of this unit are not corresponding with the coloured markings of the terminals in your plug so please proceed as follows The green and yellow wire must be connected to the plug terminal marked with the letter E with the safety earth symbol or with green and yellow colour The blue wire must be connected to the terminal marked with the letter N or with black colour The brown wire must be connected to the terminal marked with the letter L or with red colour The equipment must be connected to earth 2 3 Safety Check that the operating voltage of the unit is identical with the voltage of your local mains power If a voltage conversion is required consult your BRAHLER ICS dealer or qualified personnel Should any liquid or solid object fall into the cabinet unplug the unit and have it checked by qualified personnel before it will be used again Unplug the unit from the wall outlet or set the Main Power switch to OFF if it is not used for several days To disconnect the cord pull it out holding the plug Never pull t
5. 53 1 864 7070 F 353 1 864 5031 E Mail jon brahlerireland com United Kingdom BR HLER ICS UK Ltd Cambridge CB1 3LB Simon M Sainsbury Unit 2 The Business Center Church End T 44 1223 411 601 F 44 1223 411 602 E Mail rentals brahler ics co uk sales brahler ics co uk www brahler ics co uk BR HLER ICS UK Ltd 135 St Leonard s Street Edinburgh EH8 9RB Scotland UK Robert Duff T 44 131 662 1330 F 44 131 662 1331 E Mail ecosse brahler ics co uk MO INFRAQOM USA CONFERENCE SYSTEMS Inc 12910 Cloverleaf Center Drive Suite 100 Germantown MD 20874 U S A Rental Service John Kendrick Email jkendrick conferencesystems com System Sales Michael Bier Email mbier conferencesystems com Telephone 1 301 330 9090 Fax 1 301 330 6901 Homepage http www conferencesystems com Branch Offices San Bruno San Francisco Ken Wollitz kwollitz conferencesystems com Singapore BR HLER ICS Pte Ltd 1100 Lower Delta Road 03 02 EPL Building Singapore 169206 Contact Person J ames Holden Rental Service Alizah Abdul Aziz Telephone 465 6547 2042 Fax 465 6547 4178 Email info brahler sq Responsible for the following Countries Indonesia Cambodia Lao Myanmar Brunei Bangladesh INFRAQOM brahler Phone 49 2244 930 0 www braehler com BGE MSI 8D doc 06 4540 1
6. 6 Connecting A36 sockets INTERPRETER Two sockets A36 are provided for the connection to the interpreter consoles i e DOL7 2 About seven units may be connected directly to the MSI The total number depends on cable length If you have any questions don t hesitate to ask Our planning department will be glad to help you 4 7 Connecting mains power 90V 250V 50Hz 60Hz Connect the delivered cable with this socket to ensure the proper C working of the Compact Transmitter 13 MSI8D INFRAGOM 5 Starting Up The power supply is turned on via the power switch on the front side of the Compact SCH Transmitter MSI8D When you use the Compact Transmitter the first time it is necessary to adjust the provided channels This procedure will allocate the transmitter frequencies to the respective channels For adjusting this allocation refer to the following figure The scheme is enclosed with the Compact Transmitter as a separate sticker which may be adhering to the front panel ChOR Ch13 Ch14 Ch29 Ch30 Ch37 OFF OFF OFF Em KR SSNESE N N N SS AQ ON ON ON The following allocation is shown on the figure above First figure Channel 1 second figure Channel 16 third figure Channel 32 The left DIP switch will activate the corresponding channel DIP switch to ON means channel is active 5 1 Tuning input output levels Before starting a conference situation you should check the sound level in and output to
7. R plug for balanced output of the original language adjustable 14 6 dBV e00Ohm e LINE OUT 8 x XLR plug AF outputs for audio recording e IR LINK 2 x BNC socket 1 Connection for up to 10 INFRACOM Radiators IRad or HLN82B 2 Connection of up to 10 further INFRACOM Radiators IRad or HLN82B e RF LINK 1 x BNC socket for cascading RF with further MSI8D e INTERPRETER 2 x A36 socket for connection of Interpreter Consoles DOL7 Features e Green lighted mains switch for power ON indication e Red LEDs for channel ON indication e Green LEDs for audio available AF e 8 LEDs for interpreter control Transmission frequency e 55kHz 1335kHz channel 31 in 40kHz steps Intermediate frequency e 455 kHz Measurements e Distortion lt 0 2 e Signal to noise ratio gt 70dB e Channel separation gt 60dB Power Supply e Mains power 90 250 VAC 50 60 Hz e Power consumption 40VA max Housing e 19 2 HE Aluminium silver anodized e WxHxD 433 x 88 x 305 mm Weight e 4 6kg 17 MSI8D INFRAGOM 6 6 Optional accessories not included in delivery e INFRACOM Radiator IRad or HLN82B e INFRACOM Receiver IRX e INFRACOM Interpreter Unit DOL7 2 e BNC cable 50 Ohm different length available 18 INFRACOM MSI8D 7 Applications In the following you see some examples in form of a block diagram
8. adiator SOCKEL Se eo iet e ka 13 4 6 Connecting A36 EE 13 4 7 Connecting mainS DOWeF MKMA K kk TE BEER TE PIENO ka kaka 13 9 Starting ie 4 5 1 Tuning in put output levels ek k sek l ee ea 14 6 1 EED AF And ON on front slde s a t re ine 15 0 2 InitraredebtesE et EE 15 6 3 Thterpreber LED e ev eee on eter aha EE 15 654 0 V V OW N e 16 6 5 Technical Data MSIBD si i5 Melay ee elya t a Mann et f la ba ep beo Sina r Pe ee ies 17 6 6 Optional accessories i toc de etl b b yi kd kl kada lk p d be in b o kah kwa k re ka ku Yay 18 Te NI CG Troubleshooting RE Al SEENEN ee EEN 23 HEES ENEE osa AR IN Qe ka kal k OD ERO De odas cord D MO INFRAQOM 1 About this manual Symbols The following symbols and fonts are used in this manual Indicates an important note which has to be followed to guarantee that the functions of the unit the security of any data or your health are not put at risk ji Indicates additional information remarks and tips ES Describes activities that must be performed in the shown order Words in bold letters require your special attention INFRAQOM MO 2 Important remarks 2 1 For customers in the EU and in the USA Our equipment has been tested and complies with the requirement of the CE test This guarantees the protection against harmful interferences when the equipment is operating in a commercial environment If the
9. brahler INFRACOM Infrared Transmitter MSI8D band II Operating instructions V 1 4 Printed in Germany If you have questions about this manual please contact Brahler CS Konferenztechnik International Congress Service AG P O Box 32 64 D 53627 K nigswinter Wahlfelder M hle 3 D 53639 K nigswinter Tel 49 0 2244 930 0 E Mail sales braehler com You will find further information about our products on the internet at www braehler com 2008 BR HLER ICS AG K nigswinter All rights reserved especially also partly the translation reprint reproduction through copying or other similar methods BR HLER ICS reserves the right to make changes without notice INFRACOM and DIGIMIC are registered trademark Operating instructions INFRACOM May 09 INFRAQOM MO D 4I DANGER OF ELECTRIC SHOCK DO NOT OPEN DEVICES Do not open housing with mains cable connected Maintenance operations may only be executed by qualified personnel Our equipment and installations have been built and tested according to the latest state of the art Under normal conditions they do not require any special maintenance However please be aware of the following secure and stable position of the installation sufficient ventilation never operate equipment near heat sources such as heating radiators etc power connection install all power cables to avoid damaging connecting cables avoid trip tra
10. channel is auto matically switched on to the corresponding interpretation channel 6 1 LED AF and ON on front side AF ON CH AF This LED indicates a signal on this output for example line 1 ON This LED represents the ON status of the corresponding output channel Remark You should switch off not used channels to increase the IR power ON and OFF status is set with the left DIP switch 6 2 Infrared test diodes IR Three transmitting test diodes allow testing the receivers at a amp Q Q maximum distance of 3 meters between the test LEDs and the receiver 6 3 Interpreter LED 8 LEDs indicating the status of the corresponding INT interpreter channel Green LED means interpreter in 1 2 3 4 5 6 7 8 live O OO OO OO 0 15 MSIED INFRAQOM 8 LEDs for interpreter control 6 4 Overview INFRACOM DIP switch setting channel range XLR male LINE OUT f 90V 250V 50Hz 60Hz GR cease OR IN OR D LINE OUT um INTERPRETER RF LINK IR LINK e Trimmer IN Link connector OUT adjust BNC A36 connector for Radiator interpreter consoles connectors Illustration 2 16 INFRAQOM MO 6 5 Technical Data MSI8D The unit is complying with the international standard IEC914 Connections e OR IN 1 x XLR socket for input of the original language OR e OR OUT 1 x XL
11. he cord itself 2 4 Installation Allow adequate air circulation to prevent internal heat accumulation Do not place the unit on a surface rugs blankets etc that may block the ventilation holes Do not install the unit in locations near heat sources such as radiators or air ducts nor in places exposed to direct sunlight excessive dust or humidity mechanical vibration or shock To avoid condensation do not install the unit where the temperature may increase rapidly 2 5 Cleaning To keep the surface of the housing in a proper condition periodically clean it with a soft cloth Large staining may be removed with a cloth lightly dampened with a mild detergent Never use organic solvents such as thinners or abrasive cleaners since these might damage the surface MO INFRAQOM 2 6 Repacking Save the original shipping box and packing material For maximum protection re pack the unit as originally packed from the factory If not supplied with the equipment a complete transportation and storage box system is available from BRAHLER ICS We recommend using this system for long term protection and care 2 7 General Please keep this manual together with the INFRACOM Compact Transmitter MSI8D If you hand on the units to third parties please include this manual Please read the manual carefully taking special care when you see this symbol as it indicates AN important information C This product is conform to the rule
12. heck if there is no connection to the mains power Replace a new mains cable Turn on the POWER ON switch No clear IR signal at the IRX receiver 2 or more channels switched to the same frequency Check frequency setting on front panel and control signal using the test diodes No audio green LED does not light up No INT Interpreter signal from the interpreter console Check the DOL7 setting 21 INFRAQOM 22 Br hler Konferenztechnik International Congress Service AG la e E Wahlfelder M hle 2 D 53639 K nigswinter Tel 49 0 2244 930 256 Fax 49 0 2244 930 450 E Mail sales braehler com www braehler com Service form Repair details Equipment serial no code Fault description Date of first usage Date of delivery Delivery note no Invoice no Company customer Person to contact Telephone no E mail Comments Date company seal signature of customer Dear Customer Please always include this service form fully completed with any complaint or repair wish you may have Please note that only returns with the proper and complete paperwork can be dealt with in time Please contact us before you return equipment for repair in order to find the most efficient way of sending A detailed fault description will reduce cost and period of repair Transport damages have to be reported immediately to the respons
13. ible forwarding agent Remarks for Non EU customers Please add to each return a delivery note or a proforma invoice addressed to Br hler ICS AG K nigswinter with following statements H Reason for return repair or credit note exact declaration of the goods exact no of pieces article no model serial no H Price which has been invoiced by us better our invoice no with date Return shipments from Non EU countries have to be sent always by air freight to Cologne airport to the attention of Calenberg Oversea Logistics Mr Meregalli Mr Meininghaus Welser Str 8 D 51449 K ln Phone 49 0 2203 3592 838 Please do not ship with FedEx UPS DHL TNT Post etc because those services do not process returns but only imports Any return shipments by a m courier services will be rejected by Br hler ICS 23 INFRAQOM INFRAQOM MO Adresses Company and branch offices Head office Germany BR HLER ICS Konferenztechnik International Congress Service AG P O Box 3264 D 53627 K nigswinter Wahlfelder M hle 3 D 53639 K nigswinter T 49 0 2244 930 0 F 49 0 2244 930 450 www braehler com Rental service T 49 0 2244 930 200 F 49 0 2244 930 430 E Mail rental braehler com Sales T 49 0 2244 930 0 F 49 0 2244 930 450 E Mail salesQ braehler com Ireland BR HLER ICS Ireland Ltd Jon Sugden Unit 1 Finglas Business Park Tolka Valley Road IRL Dublin 11 T 3
14. or OFF With a rotating switch it is possible to assign up to 32 transmission channels Each channel can be set from OR Ch31 Eight green LED INT indicate the status of the corresponding interpreter channel green LED means interpreter is live This gives a quick overview about the occupied channels 10 INFRAQOM MO 904 250 Hz SOHz 6000000000 ci DT rrr pep a un The Compact Transmitter MSI8D contains the following sockets on the rear side OR IN XLR socket for feeding in the original channel CDS sound DIGIMIC sound a o The input is balanced via AF transformer OR OUT XLR socket for the output of the original sound The output is also balanced via AF transformer Trimming condenser for setting the volume of the original sound LINE OUT eight sockets for transmitting interpreter channels RF LINK BNC socket for cascading with other Compact Transmitter Use BNC T adaptor for more than two units IR LINE BNC sockets 1 and 2 for connecting INFRACOM radiators IRad or HLN82B Up to 10 radiators can be connected directly at each output INTERPRETER Two connecting sockets A36 for the connection of the interpreter consoles Mains power connector 11 MSIED INFRAGOM 4 Installation and starting up The Compact Transmitter has an ex works mains voltage setting of 90 250 Volts by 50 60 A Hz If there is another voltage range yo
15. ps liquids avoid penetration of liquids into the housing A HRH RR RH exclusively operate equipment via wall sockets that are connected to ground according to the relevant specifications and regulations Warning Never expose equipment to rain or humidity Please be also aware of the fact that rough handling of the equipment such as strong bumps or vibrations may result in damages Inappropriate handling and storage i e handling and storage not in conformity with the operating instructions may as well lead to equipment damages INFRAQOM INFRAQOM MO Content 1 About this manual 5 56 x oves eeu xw cases RD Evo uS arie eps cov ER pe Dn GRECE Ye die UR x aa aa aa reves Elle 6 2 Important remarks EES 2 1 For customers in the EU and in the USA a a 7 2 2 For customers in the United Kingdom EE 1 23 SOC Ve ee geren e aa I n 7 ZH ristall abl OR EE 7 ZINN Get ae a ee EB ee ee d Te Ae E 8 PEINE MEET TI TI I UNE 8 2 8 Important information i oie et a EAN 8 3 Short TEE SES Cei eT ET 9 EUMD P T UBER DECRETI CUORE 9 259 Compact transmitter EE 10 4 Installation and starting up eem nnns 12 4 1 Connecting the OR IN SOCKGE EE 12 4 2 Connecting the OR QUT socket ua a re haee c p ret dia E eats 12 4 3 Connecting t NE OUT SO CKELSA sa iy Ea eise a Z ra FOE n pb Ri 12 4 4 Connecting RF LINK Socket x sal kuy sih k kar Eae Ene pcs KE nube Faust ee en eu id 12 4 5 Connecting r
16. rs are about the size of a pack of cigarettes Headphones are plugged in to listen to their audio output Receivers can be moved at will anywhere within the area that is fully illuminated by the radiators They can be switched to receive up to 32 channels Whenever the INFRACOM system is used as a simultaneous interpretation installation it is operating in combination with one or several interpreter consoles The various languages are fed into the appropriate outgoing channels The interpreter consoles also include a number of functions that are essential to ensure the uninterrupted transmission of simultaneous translation These consoles are installed inside sound proofed interpreter booths Interpreters sit inside these booths and use headphones to listen to the original sound which is nor mally called the floor channel At the same time they speak their translation into an outgoing channel Wherever we have a combination of a Microphone system and DOL7 interpreter consoles it is INFRACOM s job to transmit several audio channels wireless to the auditorium The purpose of the DOL7 interpreter console is to feed in the various languages i e the interpreter s voice output onto the appropriate outgoing channel 3 2 Use In combination with a microphone management system such as CDS200 II AUTOMIC DIGIMIC the system can provide the best communication facilities for organized events that need several languages Each and every participant
17. s of the following European directive 89 336 EWG Council directive to the alignment of the rules of rights of all member states about the electromagnetic compatibility modified through RL 91 263 EWG 92 31 EWG and 93 68 EWG of the council Further information is available on request The warranty will expire if you cause defectives through inappropriate use or handling of the unit 2 8 Important information The unit should not be used at the maximum volume setting Adjust the volume to a more suitable level High sound pressure levels will damage your hearing INFRAQOM MO 3 Short description INFRACOM is a system for the wireless transmission of sound using infrared light By far the most important application is in simultaneous interpretation installations where it is combined with interpreter consoles of model DOL7 3 1 System function The INFRACOM system consists of several components The central component is the Compact Transmitter MSI8D The inputs are signals from several audio channels for instance several different language channels with simultaneous interpretation It con verts them into the appropriate FM signals for wireless transmission Infrared radiators transmit the information carried by the audio channels in the form of frequency modulated infrared light Within the radiator s area receivers are used to pick up the information transmitted in the form of in frared light signals These receive
18. simultaneous interpretation installations 3 3 Compact transmitter MSI8D INFRACOM brahler MSIED AF ON reo D IR Re IAE GA AA lA lA d e CH i Front View The INFRACOM Compact Transmitter MSI8D is part of the INFRACOM system which serves the wireless language distribution by means of infrared light The sound signal is thereby converted into a frequency modulated infrared signal and emitted via transmitting diodes With special INFRACOM receivers the signal is re converted into a sound signal which can be heard on a set of headphones Up to 8 channels can be transmitted simultaneously with an FM narrow band modulation The INFRACOM Compact Transmitter MSI8D is provided for modulating the sound signals on the different carrier frequencies and for signal amplification The Compact Transmitter consists of a 19 housing 2HU Mounting brackets for rack assembly are also available Seven languages and the original floor channel can be transmitted On the front right hand side of the Compact Transmitter MSI8D there is a green POWER ON showing the ON OFF status Next to this there are three infrared test diodes emitting the IR signal With the IR receiver you can listen to the outgoing channels even without IR Radiator The operating elements of the eight infrared channels are also on the front side of the console With miniature switches on the front panel the frequency band can be chosen and the channels can be switched ON
19. u must not connect this equipment In connecting the system special attention is to be paid to ensure that all cables are installed in cable ducts or that they are fixed by cable clamps or adhesive tape in such a way that there is no danger of somebody tripping over them 4 1 Connecting the OR IN socket XLR OR IN connector female socket for feeding in the original channel CDS ee sound DIGIMIC sound The level can be set via the trimming condenser The input is balanced via AF transformer OR IN 4 2 Connecting the OR OUT socket XLR OR OUT connector male socket for the output of the original sound The output is also balanced via AF transformer The output level can be set via a trimming condenser this is done in dependence with the input level XLR LINE OUT connector male All eight 4 3 Connecting LINE OUT sockets interpreter channels available for PA system or for recording purpose e e D 4 4 Connecting RF LINK socket 3 BNC socket for cascading another Compact Transmitter MSI8D To manage more In and Outputs you can extend the INFRACOM system up to 16 line and more outputs RF LINK 12 INFRAQOM MO 4 5 Connecting radiator sockets BNC 1 and BNC 2 BNC sockets for connecting INFRACOM radiators IRad or HLN82B Up to 10 radiators can be connected directly to each socket If there are more radiators needed we recommend the use of an active distributor IR LINK 4
Download Pdf Manuals
Related Search
Related Contents
FICHA TÉCNICA 1. NOMBRE DE LA ESPECIALIDAD Smeg NKT335E Instruction Manual Hardware manual DN 200/10/5 Samsung SHC-Z140S User Manual Furuno 100 Speaker User Manual Copyright © All rights reserved.
Failed to retrieve file