Home

CG800 SERIES - Citygrow Energy Systems

image

Contents

1. wiring connection again Notes Use standard UK wall box BS4662 minimum 35mm deep During installation of the wall box it is recommended to embed the wall box deeper inside the wall in order to give more room to install the product The room inside is recommended to have 50mm deep 7 Operation instruction 7 1 CG800S1 S2 S4 COVER PLATE 1 Cover BUTTON HOLDER Label LED Indicators ON OFF Buttons Programming Port Reset Button 1 Press ON OFF Button once to toggle between ON and OFF BRIGHT LED indicates that the Switch is ON DIMMED LED indicates that the Switch is OFF 7 2 CG800DM DM2 COVER PLATE 1 Cover MAIN UNIT Dim Up LED Indicator Label LED Indicator Dim Down LED Indicator Programming Port Reset Button 1 Press the Dim Up Dim Down button ONCE to Toggle between ON and OFF LED FLASHING indicates that that the Button was pressed and dimming is in progress When the LED stops flashing it indicates that the dimming is complete 2 Press and HOLD the Dim Up Dim Down button to begin dimming Release the button at desired level 10 7 3 CG800S2 CCP S4 CCP COVER PLATE 1 Cover BUTTON HOLDER LED Indicator Open Close Button Reset Button Programming Port 1 Press the Open Close Button once to control the electric curtain When the electric curtain is stopped press the OPEN button to o
2. Dimmer Dimmer Curtain Gang Switch Switch Leading Leading Control Curtain Edge Edge Switch Control Dimming Dimming Switch BA x2 2 5Ax4 600W 300W x2 5Ax2 paa 1 O Load current A Incandescent Halogen Electronic Incandescent Eeae Pe Solid State Low Voltage ELV Halogen Magnetic ACMOOF ae Mold Transformers Magnetic Iron Core Iron core Inductive Inductive Low Voltage MLV Low Voltage MLV Transformers Fluorescents Compact Transformers Fluorescents LEDs Motors Leading Edge Dimmable Fluorescents Compact Fluorescents and LEDs see remarks 3 4 l When up button is used for dimming up function the down button cannot be programmed as scene function Maximum number of devices programmed into the whole product is limited to 50 devices The maximum load requirements for fluorescent CFL and LED loads can vary greatly depending upon the specific fixture and or bulb being used When dimming transformer is connected to CG800 make sure dimmable and leading edge type is used Furthermore the dimming performance varies greatly from manufacturer to manufacturer of the bulb and the dimming transformer It is recommended to test the matching performance before mass deployment Maximum number of devices included in scene setting Remarks 1 2 Remarks Minimum dimming level setting Memory dim function 17 Power supply AC 220 240V 50Hz RF frequency 2 4G
3. CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL user to the presence of uninsulated dangerous voltage within the product s enclosure that may The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the A be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the product Oa IMPORTANT SAFETY INSTRUCTIONS READ BEFORE OPERATING EQUIPMENT This product was designed and manufactured to meet strict quality and safety standards There are however some installation and operation precautions which you should be particularly aware of a a a NN 10 11 12 13 14 Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions Do not install near any heat sources such as radiators heat registers stoves or other apparatus that produce heat Do not defeat the safety purpose of the polarized or grounding type plug If the provided plug does not fit into you
4. CityGrow Systems CG800 SERIES ZIGBEE WIRELESS SWITCH USER MANUAL CG800S1 CG800S2 CG800St4 CG800DM CG800DM2 One Gang Switch Two Gang Switch Four Gang Switch One Gang Dimmer Two Gang Dimmer CG800S2 CCP CG800S4 CCP One Gang Curtain Two Gang Curtain Control Switch Control Switch VERSION 1 1 17 JANUARY 2014 CityGrow Systems Disclaimers and Copyright Nothing contained in this publication is to be construed as granting any right by implication or otherwise for the manufacture sale or use in connection with any method apparatus or product covered by letters patent or as insuring anyone against liability for infringement of letters patent Efforts have been made to ensure the accuracy and reliability of the data contained in this publication however Citygrow Energy Systems Limited makes no representation warranty or guarantee in connection with this publication and hereby expressly disclaims any liability or responsibility for loss or damage resulting from its use or from the use of any product or methodology described herein for any violation of any federal state or municipal regulation with which this publication may conflict or for the infringement of any patent from the use of this publication Nothing contained in this publication should be viewed as an endorsement by Citygrow Energy Systems Limited of any particular manufacturer s products CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN
5. E KNANG KK AA KAANKKANKKKA KKK KKKA ANG 11 7 3 1 Setting the open and close travel distant for the curtain 12 8 Adding the product to your Home Wireless ZigBee Network ssusa 14 De TOV SIV AA AA AA AA 15 LO SPEECH CA ON tease ices eres KANAN NAA PANGA NAA GA 17 1 Introduction Thank you for buying Citygrow s product CG800 Series is both powerful and easy to use and install These products are specially designed for Home Automation application Description ie 10 11 12 13 14 ZigBee wireless remote control Based on IEEE 802 15 4 2 4GHz radio frequency CG800S1 S2 S4 DM DM2 is for lighting control CG800S2 CCP CG800S4 CCP is for control of electronic curtain or window blind LED indicator for on off status Load loads are directly driven by the build in driver Control button can be configured to become two way function Control button can be configured to become scene function Support iPhone iPad and Android mobile control if CG102BS Base station is purchased Control button graphics can be tailor made per customer requirement Mounted in a standard UK wall box No EIB Bus required Easy to install CityGrow Systems 2 Understanding of the product Frame Button panel Front view NYX Button panel bottom view Control button Connector to 4 control unit Reset button Programming port Metal clip to fix the butt
6. HZ 2 4GHZ 2 4GHZ 2 4GHZ 2 4GHZ 2 4GHZ 2 4GHZ Remote control distance 100M 100M 100M 100M 100M 100M 100M M line of sight Dimensions mm Length 87x87x39 87x87x39 87x87x39 87x87x39 87x87x39 87x87x39 87x87x39 x Width x Depth Recommended operation 0 to 40 0 to 40 0 to 40 0 to 40 0 to 40 O to 40 0 to 40 temperature degC degC degC degC degC degC degC 18
7. d possible damage to equipment WARNING Do not operate when any lamps removed or burned out replace any burned out lamps immediately use only transformers that incorporate thermal protection or fused primary windings This product is designed for residential and commercial use for indoor use only WARNING Install in accordance with all national and local electrical codes IMPORTANT Citygrow is not liable for any damage incurred with the misuse of this product IMPORTANT Pre setup can only be done by a professional worker or manufacturer agent 6 6 Installation In order to install the product correctly please follow the below steps STEP 1 IMPORTANT Turn off main power at the main switch board STEP 2 Loosen the screws of the original wall switch Remove the switch and disassemble the wiring STEP 3 Connect the main power cable to the Live and Neutral terminals and the load cable to the Load terminals at the rear cabinet of the product STEP 4 Fasten the screws of all terminals and check that the wires are properly secured Retrofit the switch into the standard switch box and mount it on the wall by fastening the two screws at the rear of the switch box Screw x 2 pcs crew x 4 pcs CG800 power unit CG800 frame CG800 button panel STEP 5 Push the ON OFF Button to test whether the wiring has been connected correctly If the ON OFF Button does not function as expected please check the
8. ireless ZigBee Network 14 STEP 1 Open the front cover you will see a 5 pin connector programming port STEP 2 Plug the CG101UT5 cable into the 5 pin socket of the product and then plug the other end of the CG101UT5 cable into the mini USB end of the CG101UTC cable STEP 3 Plug the CG101UTC cable into the USB port of a PC that is installed with Citygrow s HomeNET Planner Software STEP 4 Refer to the user manual of HomeNET Planner Software to program and set the address of the product 9 Clear Memory Clearing the memory inside of the product will result in 1 The product will no longer reply to any Panels that it had previously bound to 2 The product will no longer reply to any Remotes that it had previously bound to In order to perform the Clear Memory function please follow the below steps STEP 1 Press and HOLD anyone of the ON OFF Button STEP 2 CONTINUE holding onto the ON OFF Button Press and release the Reset Button once STEP 3 Wait until the LED Indicator begins BLINKING Release the ON OFF Button 15 STEP 4 Press and release the ON OFF Button again to stop blinking STEP 5 Press and release the Reset Button The memory inside of the product has now been cleared 16 10 Specification CG800S1 CG800S2 CG800S4 CG800DM CG800DM2 CG800S2 CG800S4 CCP CCP Description One Two Four Gang One Gang Two Gang One Gang Two Gang Gang Switch
9. on panel Control unit bottom VENN Model number plate 4 3 Load terminals gt 1 Neutral Black Live Brown Load terminal to Model number chart tani efe CG800S2 CCP One Gang Curtain Control Switch Motor 1 Motor 1 Forward Backward CG800S4 CCP Two Gang Curtain Control Switch Motor 1 Motor 1 Motor 2 Motor 2 Forward Backward Forward Backward 3 Dimensions 27 8mm i 40mm 85mm 4 Wiring CG800S1 S2 S4 DM DM2 Situation 1 Live Neutral and Load wires are ready at wall box Notes The Neutral wire of load is closely connected to the Neutral point of CG800 Load terminals See Table 4A TO HG ng amp Lamp a CG800S1 4 3 2 1 Ca Distribution panel Situation 2 Neutral wire is only ready at ceiling Notes The Neutral wire of load is closely connected to the Neutral point of CG800 Lamp Table 4A Load terminals CG800S1 One Gang Switch CG800S2 Two Gang Switch CG800S4 Four Gang Switch CG800DM One Gang Dimmer CG800DM2 Two Gang Dimmer CG800S2 CCP One Gang Curtain Motor 1 Motor 1 Control Switch Forward Backward CG800S4 CCP Two Gang Curtain Motor 1 Motor 1 Motor 2 Motor 2 Control Switch Forward Backward Forward Backward Before getting started WARNING It must be installed by a qualified electrician in accordance with all applicable regulations and building codes Improper wiring can res
10. pen the electric curtain When the electric curtain is stopped press the CLOSE button to close the electric curtain When the electric curtain is running press ANY button to stop the electric curtain 11 7 3 1 Setting the open and close travel distant for the curtain The function of the Learning Mode in the CG800S2 CCP or CG800S4 CCP is to program the duration of the curtain Opening Closing time In order to perform the Learning Mode function please follow the below steps 12 STEP 1 Press the CLOSE Button until the curtain is fully closed NOTE You may have to press the Button once or more times in order for the curtain to be fully closed STEP 2 Press and HOLD the Reset Button While still holding the Reset Button press and HOLD the Open Button STEP 3 Release the Reset Button Wait until the LED Indicators begins BLINKING Release the Open Button NOTE The curtain should be opening at this point STEP 4 Once the curtain is fully opened press and release any Button NOTE The duration of the Opening Closing time will be stored once the Button is pressed STEP 5 Use a thin object to press the Reset Button again The learning process of the CG800S2 CCP or CG800S4 CCP has now finished 13 8 Adding the product to your Home W
11. r outlet consult an electrician for replacement of the outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manufacturer Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over Unplug this apparatus during lightning storms Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Table of content l INO AA 1 2 Understanding of the product a 2 Su DIMENSION AA AA AA 3 4 Wiring CG800S1 52 S4 DM DM2 mmaaanwaawaaaaaaaaaaaanaaanaanaaa nananana nkaka 4 5 Wiring CG80052 CCP S4 CCP aa nananana wanna anna na NN NAAN KKANKKA NN KA AN KK AKN NAKAKA 6 o TA SEAINQU OMT oeeeaecintencaeeidsncasced E E E A 7 7 Operation instruction nakaasawa koala koala makes kanako sakon ieceiorseceiecsvecsiecsiecciessu 9 Zis G C1 1010 159 PR Y ES PAA AA AA AA 9 7 SY PE 8C 010 BP PAA 10 7 3 CG80052 CCP S4 CCP aa nananana naaawa manna ANN
12. ult in personal injury or damage to control units or other equipment Always turn off circuit breaker or remove main fuse from power line before doing any work To avoid overheating and possible damage to equipment WARNING Do not operate when any lamps removed or burned out replace any burned out lamps immediately use only transformers that incorporate thermal protection or fused primary windings This product is designed for residential and commercial use for indoor use only WARNING Install in accordance with all national and local electrical codes IMPORTANT Citygrow is not liable for any damage incurred with the misuse of this product IMPORTANT Pre setup can only be done by a professional worker or manufacturer agent 5 Wiring CG800S2 CCP S4 CCP Notes The Neutral wire of load is closely connected to the Neutral point of CG800 Neutral Ba e Live congue B C Curtain motor AC AAAN mer One fo a Wall box rs Distribution panel T Conduit CG80052 CCP 4 Wall box Load 3 terminals 2 1 See Table 4A NG Aa NG NN Before getting started peee gt WARNING It must be installed by a qualified electrician in accordance with all applicable regulations and building codes Improper wiring can result in personal injury or damage to control units or other equipment Always turn off circuit breaker or remove main fuse from power line before doing any work To avoid overheating an

Download Pdf Manuals

image

Related Search

Related Contents

Silicone Aquarium  L`affiche "Comment prendre correctement sa tension"  Mode d`emploi Istruzioni per l`uso Operating Instructions  Space engineering Explosive systems and devices  Pioneer Home Theater Dock  organismes - CDEC Rosemont-Petite  Scariche - Digital 2000 Srl  Dialog-Betrieb    Thème : Bactéries multi résistantes isolées des hémocultures au  