1. AAMPROBE IR 710 10 1 IR thermometer Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso Anvandarhandbok 710 10 1 IR thermometer Users Manual September 2011 Rev 1 2011 Amprobe Test Tools All rights reserved Printed in China Limited Warranty and Limitation of Liability Your Amprobe product will be free from defects in material and workmanship for 1 year from the date of purchase unless local laws require otherwise This warranty does not cover fuses disposable batteries or damage from accident neglect misuse alteration contamination or abnormal conditions of operation or handling Resellers are not authorized to extend any other warranty on Amprobe s behalf To obtain service during the warranty period return the product with proof of purchase to an authorized Amprobe Test Tools Service Center or to an Amprobe dealer or distributor See Repair Section for details THIS WARRANTY IS YOUR ONLY REMEDY ALL OTHER WARRANTIES WHETHER EXPRESS IMPLIED OR STAUTORY INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY ARE HEREBY DISCLAIMED MANUFACTURER SHALL NOT BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES ARISING FROM ANY CAUSE OR THEORY Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential d
2. are damaged or missing return the complete package to the place of purchase for an exchange FEATURES The Amprobe IR 710 a 10 1 spot to distance ratio infrared thermometer offers best in class accuracy and response time with a temperature measurement range of 0 F to 716 F or 18 C to 380 C The IR 710 is specifically designed for HVAC R electrical industrial maintenance automotive as well as quality control and fire prevention applications 10 1 Distance to Spot Ratio Temp Range of 0 F to 716 F or 18 C to 380 C Precision accuracy and rapid response time Laser pointer backlit dual LCD Display Auto display hold and MAX MIN memory HOW THE THERMOMETERS WORK Infrared thermometers measure the surface temperature of an object The thermometer s optics sense emitted reflected and transmitted energy which is collected and focused onto a detector The unit s electronics translate the signal into a temperature reading which the unit displays OPERATING THE THERMOMETER Temperature Measurement The Thermometer turns on when you press the trigger The Thermometer turns off when no activity is detected for 8 seconds To measure temperature point the thermometer at an object and pull the trigger You can use the laser pointer to help aim the thermometer Pull and hold the trigger when measuring the target surface When release the trigger the display will hold the reading for 8 seconds Be sure to cons
3. amages this limitation of liability may not apply to you Repair test tools returned for warranty or non warranty repair or for calibration should be accompanied by the following your name company s name address telephone number and proof of purchase Additionally please include a brief description of the problem or the service requested and include the test leads with the meter Non warranty repair or replacement charges should be remitted in the form of a check a money order credit card with expiration date or a purchase order made payable to Amprobe Test Tools In Warranty Repairs and Replacement All Countries Please read the warranty statement and check your battery before requesting repair During the warranty period any defective test tool can be returned to your Amprobe Test Tools distributor for an exchange for the same or like product Please check the Where to Buy section on www amprobe com for a list of distributors near you Additionally in the United States and Canada In Warranty repair and replacement units can also be sent to a Amprobe Test Tools Service Center see address next page Non Warranty Repairs and Replacement US and Canada Non warranty repairs in the United States and Canada should be sent to a Amprobe Test Tools Service Center Call Amprobe Test Tools or inquire at your point of purchase for current repair and replacement rates In USA In Canada Amprobe Test Tools Amprobe Test To
4. ider distance to spot size ratio and field of view The laser is used for aiming only and is not related to temperature measurement The thermometer features an auto off function that automatically powers down the thermometer after 8 seconds of inactivity To turn the thermometer on pull the trigger Hnn Button Description C F Toggle between Celsius and Fahrenheit MAX Toggle between MAX and MIN MIN options MAX or MIN reading is displayed on the secondary display A Turn off or on the laser 9 A Turn off or on display backlight AN AALaser To avoid injury do not point the laser directly at eye or indirectly off reflective surfaces The thermometer is equipped with a laser used for aiming purposes only The laser turns off when the trigger is released To enable or disable the laser 1 Press button to enable or disable the laser Symbol appears on the display when laser is enabled Locating a Hot or Cold Spot To find a hot or cold spot aim the Thermometer outside the target area Then slowly scan across the area with an up and down motion until you located the hot or cold spot Distance and Spot Size As the distance D from the target being measured increases the spot size S of the area measured by the instrument becomes larger The spot size indicates 90 encircled energy Locating a Hot or Cold Spot Make sure that the ta
5. ols Everett WA 98203 Mississauga 142 1X9 Tel 877 AMPROBE 267 7623 Tel 905 890 7600 Non Warranty Repairs and Replacement Europe European non warranty units can be replaced by your Amprobe amp Test Tools distributor for a nominal charge Please check the Where to Buy section on www amprobe com for a list of distributors near you European Correspondence Address Amprobe Test Tools Europe In den Engematten 14 79286 Glottertal Germany Tel 49 0 7684 8009 0 Correspondence only no repair or replacement available from this address European customers please contact your distributor IR 710 10 1 thermometer 9 IT HOLD 5 Q MAX e im Q A F FOO HB boo HOLD A scan V A d pang Laser Aperture Trigger Battery Cover Display Hold After releasing the trigger Laser Indicator Temperature Unit C F MAX MIN Temperature Display Backlight Q Low Battery Indicator Making Measurement Pulling the trigger 5 SYMBOLS dcc n 1 SAFETY INFORMATION AAA 1 UNPACKING AND INSPECTION 3 22220 3 HOW THE THERMOMETERS WORK 3 OPERATING THE 4 Tem
6. ot stare into laser beam Do not point laser directly at eye or indirectly off reflective surfaces For use by competent persons only Do not point laser directly at eye or indirectly off reflective surfaces Replace the batteries as soon as the low battery indicator appears Verify the Tester s operation by measuring on a known voltage source Do not use the thermometer if it operates abnormally Do not operate the thermometer around explosive gas vapor or dust To avoid a burn hazard or fire know that reflective objects may be much hotter than the indicated temperature reading Do not leave the thermometer on or near objects of high temperature If the thermometer is used in a manner not specified by this manual the protection provided by the thermometer may be impaired or may result in hazardous laser radiation exposure Cautions To avoid damaging the thermometer under measurement protect them from the following Do not stare into laser beam EMF electro magnetic fields from arc welders induction heaters Static electricity Thermal shock caused by large or abrupt ambient temperature changes allow 30 minutes for instrument to stabilize before use Do not leave the thermometer on or near objects of high temperature AND INSPECTION Your shipping carton should include 1 710 Thermometer 1 9V battery installed 1 Users Manual If any of the items
7. perature Measurement 224 Locating Hot or Cold Spot m Distance and Spot Size 5 Field of VIG 5er ch ree NEEN 6 ose e 7 Reminders PEPPER US 7 Kaell ul el DEE 8 4 10 TROUBLE 5 4 2 22 11 SYMBOLS Caution Refer to the explanation in this Manual A Warning Laser light Do not stare into laser beam C Celsius F Fahrenheit Battery indication C Complies with European Directives Do not dispose of this product as unsorted municipal waste Contact a qualified recycler Safety Information The instrument complies with EN 61010 1 General Safety EN 60825 1 Laser Safety EN 61326 1Electromagnetic Emissions and Susceptibility A CAUTION AVOID EXPOSURE LASER RADIATION 15 EMITTED FROM THIS APERTURE ay LASER RADIATION DO NO STARE INTO BEAM OUTPUT 1mW WAVELENGTH 630 670nm LASER CLASS 2 PRODUCT COMPLIES WITH FDA 21CFR 1040 10 1040 11 amp EN 60825 1 For use by competent persons only CAUTION AVOID EXPOSURE LASER RADIATION IS LASER RADIATION OUTPUT ImW WAVELENGTH 630 670nm E LASER CLASS 2 PRODUCT dt For use by competent persons ITED FROM THIS APERTURE NO STARE INTO e Laser aperture Warning Read Before Using Do n
8. rget is larger than the spot size The smaller the target the closer you should be to it SCAN i cco m CID Liss Emissivity Emissivity describes the energy emitting characteristics of materials Most organic materials and painted or oxidized surfaces have an emissivity of about 0 95 If possible to compensate for inaccurate readings that may result from measuring shiny metal surfaces cover the surface to be measured with masking tape or flat black paint lt 150 C 302 F and use the high emissivity setting Allow time for the tape or paint to reach the same temperatures as the surface beneath it Measure the temperature of the tape or painted surface Reminders 1 Changes of surrounding ambient temperature can result in inaccurate reading allow time for the instrument to adopt the change of ambient before use Specified accuracy applies after 30 minutes when the instrument changes to a different environment ambient 25 CI77F 35 95 Wait for 30 minutes 2 The instrument cannot measure through transparent surfaces such as glass It will measure the surface temperature of the glass instead ALI MAX w 90 3 Not recommended for use in measuring shiny or polished metal surfaces stainless steel aluminum etc See Emissivity 4 Steam dust smoke etc can prevent accura
9. ry installed MAINTENANCE Lens Cleaning Blow off loose particles using clean compressed air Gently brush remaining debris away with a camel s hair brush Carefully wipe the surface with a moist cotton swab The swab may be moistened with water or rubbing alcohol Note Do not use solvents to clean the plastic lens Case Cleaning Use soap and water on a damp sponge or soft cloth Note do not submerge the unit in water 10 TROUBLE SHOOTING Code Problem Action Select target OL Target temperature is within over range TI specifications Select target OL Target temperature is within under range take specifications Battery Check and or indication Low battery replace battery e Check and or Blank display Possible dead battery replace battery 1 Replace Laser doesn t red dead battery battery work 2 Ambient temperature 2 Use in area above 40 C 104 F with lower 11 To install or change one 9V battery see below 1 Open the handle 2 Install the battery noting its correct polarity 3 Close and lock the handle Battery 9V 6F22 alkaline battery or equivalent H Es di l ov d Ce 12 Visit www Amprobe com for Catalog Application notes Product specifications User manuals 6 Please Recycle
10. te measurement by obstructing the instrument s optics SPECIFICATION Function Range Temperature Range O F to 716 F 18 C to 380 C Accuracy With ambient operating temperature of 21 C to 25 C 70 F to 77 F 18 C to 10 C 0 4 F to 50 F 2 1 2 F or 3 C 46 F whichever is greater gt 10 C to 380 C gt 50 F to 716 F 2 or 2 C 4 F whichever is greater Repeatability 0 5 of reading or 0 5 C 1 F whichever is greater Display Resolution 0 1 C 0 1 F Spectral Response Bum to14um Laser Sighting Single point laser Laser Power Output gt 1mW Class 2 wavelength 630 to 670nm Response Time 95 500ms Distance to Spot D S 10 1 Minimum Spot Size 20mm Emissivity 0 95 Ambient Operating 0 C to 50 C Temperature 32 F to 120 F Relative Humidity 0 to 75 non condensing 20 C to 65 C Storage Temperature 4 F to 150 F Battery not installed Temperature Display C or F selectable Display Hold 8 sec MAX MIN Temperature Display Dual LCD Display LCD Backlit Low Battery Jj Indication 9V 6F22 alkaline battery or Power equivalent Battery Life 10 hours with laser and backlight on 30 hours with laser and backlight off Dimension Approx 153 x 108 x 40 mm HxLx W 6 0 x 4 3 x 1 6 in d Weight Approx 180 g 0 4 Ib Weight with batte