Home

User manual

image

Contents

1. Zone 1 Magnetic door contact Zone 2 Shock sensor e Zone 1 Magnetic door contact Zone 2 Water sensor e Zone 1 External Sensor Zone 2 Shock sensor e Zone1 Magnetic door contact Zone2 N A e Zonel External Sensor Zone2 N A e Zone1 N A Zone 2 Shock sensor e Zone1 N A Zone 2 Water sensor Neu Water sensor mode is not supported when EWD2 is used with ESIM264 alarm system In case of tamper violation the alarm is caused regardless of system being armed or disarmed There are 2 ways to detect tamper violation on EWD2 e By tamper switch EWD2 comes equipped with 2 built in tamper switches intended for enclosure supervision e one located on the front side of the PCB supervising the front cover in case it is illegally opened see Fig No 1 e the other one located on back of the PCB supervising the back side of the enclosure in case the EWD2 is illegally detached from the wall see Fig No 1 Once the enclosure of EWD2 is tampered the tamper switch will become triggered This action will be followed by alarm resulting in sending an SMS text message and or phone call to the user The SMS text message contains the violated tamper number e By wireless connection loss The wireless connection loss between EWD2 and ESIM364 system leads to alarm The system identifies this event as a tamper violation and sends alarm by SMS text message and phone call to the user s by default The SMS text message contains the violated tamper n
2. screwdriver or any other tool and push it down EWD2 Manual v 1 3 8 Screw inthe magnet to the door or window frame and ensure that the magnet is fixed at the same height as the EWD2 magnet detec tor 1 20mm max mn gt 10 Remove the plastic tab inserted between one of the battery terminals and battery slots of EWD2 9 Coverthe magnet No tools are required for this action 11 Close EWD2 enclosure using the cover No tools are required for this action 12 Bind the device to the alarm system using ELDES Configuration Tool software Open Wireless Device Management section and en ter a 8 digit wireless device ID located on the EWD2 enclosure and press Add button see Fig No 15 The device can also be bound by sending a corresponding command via SMS text message For more details please refer to the software s HELP section and ELDES alarm system installation manual less Zone Tamper Alarm Quege Wireless Device Management Device ID 58122812 A EWF1 1D 02000011 TAmper ALARMI GJ lt Back 1 5 Next gt Device Type EWF CONNECTED 5 h earc Temperature 30 C Device ID Battery Level 0 Signallevel Caz 13 Upon the successful binding process EWD2 device icon becomes visible in Wireless Device Management section as well as Battery Level and Signal Level If the attempt to bind is unsuccessful try to move EWD2 closer to
3. such as medical devices e DONOT use the system in hazardous environments e DONOT expose the system to high humidity chemical environments or mechanical impact e DONOT attempt to repair the system yourself any repairs must be carried out by fully qualified personnel only The WEEE Waste Electrical and Electronic Equipment marking on this product see left or its documentation indicates that the product must not be disposed of together with household waste To prevent possible harm to human health and or the environment the product must be disposed on in an approved and environmentally safe recycling process For further infor mation on how to dispose of this product correctly contact the system supplier or the local authority responsible for waste EE disposal in your area Copyright ELDES UAB 2013 All rights reserved It is strictly forbidden to copy and distribute information in this document or pass to a third party without an advanced written authorization from ELDES UAB ELDES UAB reserves the right to update or modify this document and or related products without a warning Hereby ELDES UAB declares that the wireless door contact shock sensor EWD2 in compli ance with the essential requirements and other relevant provisions of Directive 1999 5 EC The declaration of conformity may be consulted at www eldes It EWD2 Manual v 1 3 Made in the European Union www eldes lt
4. acis 1 2 TECHNICAL SPECIFICATIONS 2 1 Electrical and Mechanical Characteristics PIE EC TICS sop nscassceaenpascussmeacnsantdsnu atasancsnsanbansongesnsstweisesstenesndstaasamacianioteags 1 5V Alkaline AAAA type LR8 IEC standard 25A ANSI NEDA standard Number of Bat TONES an 2 Battery operation tiMe sss nende 18 months Wireless transmitter receiver frequency nnee 868 Mhz Wireless communication range au Up to 30 meters in premises up to 150 meters in open areas Range of operating temperatures nnee neen eeneneneenrenn 20 55 C Pumidity ae 0 90 RH 0 40 C non condensing EWD2 dimensions ae ae na 101x22x20 mm Magnet dimensions 47x17x10 mm Compatible with alarm systems unenenernenenenensnnenennnnenennnenenenennnne ann ELDES wireless The operation time might vary in different conditions 2 EN EWD2 Manual v 1 3 2 2 Main Unit and LED Functionality En FRONT SIDE TAMP1 DETECT BACK SIDE a DETECT Unit Description Z Zone terminal COM Common terminal TAMP1 Tamper switch Battery slots DETECT Magnet detector LED Light emitting diode for indication of parameter restoring to default RESET Button for restoring default parameters TAMP2 Tamper switch 3 INSTALLATION AH Before installing the wireless device we highly recommend to refer to RADIO SYSTEM INSTALLATION AND SIGNAL PENETRA TION manual located at www eldes lt download 1 Remo
5. he RESET button 3 Insert the battery back to EWD2 4 Hold the RESET button until LED indicator provides several short flashes 5 Release the RESET button 6 Parameters restored to default 7 ADDITIONAL INFORMATION Limited Liability The buyer must agree that the system will reduce the risk of fire theft burglary or other dangers but does not guarantee against such events ELDES UAB will not take any responsibility regarding personal or property or revenue loss while using the system ELDES UAB liability according to local laws does not exceed value of the purchased system ELDES UAB is not affiliated with any of the cellular providers therefore is not responsible for the quality of cellular service Manufacturer Warranty The system carries a 24 month warranty by the manufacturer ELDES UAB Warranty period starts from the day the system has been purchased by the end user The warranty is valid only if the system has been used as intended following all guidelines listed in the manual and within specified operating conditions Receipt must be kept as a proof of purchase date The warranty is voided if the system has been exposed to mechanical impact chemicals high humidity fluids corrosive and hazardous environment or other force majeure factors SAFETY INSTRUCTIONS Please read and follow these safety guidelines to safeguard yourself and others e DONOT use the system where it can interfere with other devices
6. oldes EWD2 eldes WIRELESS MAGNETIC DOOR CONTACT SHOCK SENSOR User manual v1 3 Compatible with e ESIM264 v7 14 03 and up EWT1 v16 18 and up e ESIM364 v02 06 05 and up e EPIR2v01 01 12 and up Main features e Built in shock sensor e 2 wireless zones e Available zone modes magnetic door contact shock sensor water sensor digital sensor e 2 built in tamper switches on the front and on the back of the PCB EWD2 is a wireless device intended to secure doors windows or any other opening clsoing mechanisms In addition the device comes equiped with a built in shock sensor for vibration detection an on board zone terminal designed for external digital sensor or water sensor connection and 2 built in tamper switches for EWD2 sabotage detection In order to start using EWD2 it has to be bound to ELDES alarm system using ELDES Configuration Toolsoftware or by sending a corresponding SMS text message to ELDES alarm system Itis possible to connect up to 16 EWD2 devices to ESIM264 and EPIR2 systems while to ESIM364 alarm system up to 32 EWD devices ata time The maximum wireless connection range is 150 meters in open areas eg For complete information on device operation with ELDES alarm system please refer to ELDES alarm system installation manual located at www eldes It download 1 CONTENTS OF PACK Item Quantity TE WUD 2 nme 1 2 MagHet na a 1 3 1 5V Alkaline AAAA type batteries 2 4 STEWS ee 4 5 USE manual sm
7. the ELDES alarm system and bind anew 14 EWD2 is ready for use AREN Ensure that EWD2 device is properly fixed to the wall and the Mounting Point B portrayed in Fig No 5 is properly screwed in Otherwise the tamper switch will NOT supervise the back side of EWD2 enclosure see also 4 EWD2 ZONES AND TAMPERS AH If you are unable to bind the wireless device please restore the parameters of the wireless device to default and try again See 6 Restoring Default Parameters for more details EWD Manual v 1 3 4 EWD2 ZONES AND TAMPERS Upon successful EWD2 magnetic door contact binding process the system adds 2 wireless Instant zones The wireless zones can be set up to operate under one of the following modes each e Zonel e Magnetic door contact Designed for causing an alarm by default if doors windows are opened when the system is armed e External sensor Designed for causing an alarm by default if the wired digital sensor connected to Z and COM terminals is triggered when the system is armed This mode does NOT operate with Water sensor mode on Zone 2 simultaneously e Zone2 e Shock sensor Designed for causing an alarm by default if the built in shock sensor is triggered e Water sensor Designed for causing an alarm by default if a water sensor connected to Z and COM terminals is triggered This mode does NOT operate with External sensor mode on Zone 1 simultaneously Possible zone mode combinations e
8. umber and a Star character indicating wireless connection loss as a tamper alarm cause eset The tamper will not operate if both wireless zones are disabled For more details on EWD2 zone and tamper configuration please refer to ELDES Configuration Tool software s HELP section 5 BATTERY REPLACEMENT 1 Open EWD2 enclosure Remove both old batteries from the battery slots 3 Insert the 2 new 1 5V Alkaline AAAA type batteries according to the appropriate battery slot positive negative terminals indicated on the PCB of EWD2 4 Batteries replaced See 3 INSTALLATION for more details eee Only 1 5V Alkaline AAAA type batteries can be used Install only new high quality and unexpired batteries Do not mix the old batteries with the new ones AREN Ne At least 1 battery must be removed if the device is not in use AREN Ne In order to avoid fire or explosion hazards the system must be used only with approved battery Special care must be taken when connecting positive and negative battery terminals Dispose old batteries only into special collection sites Do not charge disassemble heat or incinerate old batteries AREN NEO H The system sends an SMS message to a preset user phone number as soon as the battery level runs below 5 AREN The battery status can be monitored in real time using ELDES Configuration Tool software g EWD2 Manual v 1 3 6 RESTORING DEFAULT PARAMETERS 1 Remove any battery from EWD2 2 Press and hold t
9. ve the cover of EWD2 enclosure Press and hold Insert a Screwdriver or any other tool and push it down a Press and hold b Pull up the edge of the PCB gt EWD2 Manual v 1 3 3 Screw in the enclsoure to the door or window jamb MOUNTING POINT A MOUNTING POINT B Ensure to screw in properly for supervision of the back side by tamper switch 4 When installing EWD2 follow the recommendations for the installation to achieve the strongest wireless signal Wireless device 0 5mto30m _ inside the ei 0 EE m to 150 m in open areas aa EPIR2 device Never install in the following locations inside the metal cabinet closer than 20 cm from the metal surface and or power lines Recommended face the front side of the wireless device towards the front side of EPIR2 keep the distance 0 5 m to 30 m inside the building 0 5 m to 150 m in open areas 0 5 m to 30 m _inside the building 0 5 m to 150 m in open areas Wireless antenna Wireless device Recommended face the front side of the wireless device towards the antenna keep the distance 0 5 m to 30 m inside the building 0 5 m to 150 m in open areas 5 Wire up the external digital sensor if any or water sensor if any to Z and COM terminals otherwise do not perform any wiring 6 Insertthe PCB back into the enclosure 7 Remove the cover of the magnet enclosure a Insert a

Download Pdf Manuals

image

Related Search

Related Contents

Manual TA410  Untitled - Lidl Service Website    - Frank`s Hospital Workshop  Descarga el Catálogo de Penetron  Samsung YP-U1Q Uživatelská přiručka  Transcend PF 730  

Copyright © All rights reserved.