1. Blinking empty position no stored number GP Fix full position stored number 2 Pressanumberfrom 1 to 0 3 Press INVIO If in the choosed position there is already a telephone number stored it will be displayed immediately So it needs pressing dy i INVIO again during the number visualization to change it 4 Digit the telephone number Yy Digit the telephone 5 Press INVIO number 13 Monochannel telephone dialer User manual A cA 14 Repeat from the point 2 to introduce the others telephone numbers i After introducing all the telephone numbers they can be also less than 10 press PAUSA ABB one time to exit from the numbers introduction phase or two times to exit from the programming NOTE Itis possible to exit from the current phase in each moment pressing GIA 3 1 2 Message recording Digit the programming code then press the 2 key 1 Press 1 to record the message 2 Press INVIO at the end of the message recording Each message can last 24 seconds at the most after which the telephone dialer disables automatically When the recording phase is ended the dialer repeats the recorded message automatically and it returns to the point 1 If the operation is repeated the new message takes the place of that previous Press PAUSA ABB one time to exit fro
2. Monochannel telephone dialer ENGLISH USER MANUAL Monochannel telephone dialer User manual a cA Index Chapter 1 ER EN ER ON Chapter 2 Chapter 3 3 1 Introduction 4 Description of the telephone dialer EE SEKERES sense 4 Operating features Technical specifications Installation 7 En ENEE 7 Terminal board description 8 ele TEE 9 Programming 10 Programming fini EE eee 3 1 1 Telephone numbers introduction vias 3 12 Message Tecording EE 3 1 3 Pulse DTMF SENG EE GWA EE GIA Index Chapter 4 Operating 18 EE ell TEE 18 4 2 Telephone dialer enabling nennen 19 4 3 Telephone numbers visualization 20 4 4 Telephone numbers changing weal 4 5 Telephone numbers Gancellig iii en een de 22 E le EE e EE 4 7 Callings cycle repeating 4 8 Message repeating ee Re Re W 4 9 Dialer state visualization during the callings phase 26 4 10 Programming cod Changing 4 SEA EE nee 27 Chapter5 Maintenance 28 9 1 CIGAMING E 5 2 Default values setting in factory Monochannel telephone dialer User manual a A 1 Introduction Dear customer we desire thank you for buying a CIA product We recommend you to read this manual with attention because it will be very useful during the installation and use phase As CIA customer you can make use of a series of services such as the technical telephone assist
3. User manual a cA 4 Operating 4 1 Panel description Loud speaker for listening recorded messages and for the visualization during test phase Included microphone for the messages recording Numerical display Twelve keys pad RESET key MP RE GIA Operating 4 2 Dealer enabling To enable the telephone dialer it needs setting a positive 13Vcc to the clamp ON 6 that allows the dialer enabling after setting a tension of 13Vcc to the clamp A 7 the dialer starts the calling phases to the stored numbers from 1 to 0 see 3 1 1 After the enabling the telephone dialer will make the following phases 1 Connection with the telephone line E 2 telephone numbers dialing 8 d 3 Waiting CH 4 Message sending i 5 End of connection al 19 Monochannel telephone dialer User manual 4 3 Telephone numbers visualization Digit the programming code then press the 1 key 1 Press a number from 1 to 0 corresponding to the telephone number to visualize CD 2 Press INVIO to visualize the telephone number 20 3 Press PAUSA ABB one time to exit from the visualizing phase or two times to exit the programming phase N B Successively the scheme on the left ofeach paragraph will indicate to dial the programming code and then to press the number in black to startthe choice phase 4 Be Visu
4. TM81P 180x115x34mm CT81 178x115x38mm TD81 285x95x17mm TM81P GIA Installation DECLARATION OF CONFORMITY PRODUCER HiLTRON S r l ADDRESS Cire Est di Napoli compls Lemar 80026 Casoria NA Italy PRODUCT MONOCHANNEL TELEPHONE DIALER PRODUCT CODE CT81 TD81 TM81P THE DESCRIBED PRODUCTS ARE MADE ACCORDING TO THE REQUISITES OF THE FOLLOWING STANDARDS APPLYED STANDARD TITLE EN50081 1 EMISSION GENERIC STANDARD Class ofthe generic standard home commercial and light industrial EN50082 1 IMMUNITY GENERIC STANDARD Class ofthe generic standard home commercial and light industrial CONFORMITY WAS VALUED ON TESTS MADE ON SAMPLE AND WITH ORIGINAL SETUP OF THE DEVICES FUNCTIONAL CONFIGURATION OPERATING THEREFORE THE PRODUCT SATISFY THE REQUISITES OF THE 89 336 CEE DIRECTIVE VA DATE EE a A AGER 4 Marzo 1999 Fa Monochannel telephone dialer User manual A cA 2 Installation 2 1 General instructions e _ Noinstalling the telephone dialer exposed to the bad weather or to the extreme temperatures e Forastrong and safe fixing it needs making sure the wall surface is plane e _ Fixthe telephone dialer at a height that allows an easy access to the frontal panel e The telephone dialer is protected by tampering but the installation in a safe place is an additional protection e The telephone dialer must be connected with a burglary system according to CEI 79 3 Special Standards for the burglary anti in
5. 1 to listen the recorded message After listening the message press PAUSA ABB one time to exit y from the listening phase or two times to exit from the programming Operating PL Y Reprod mess 23 Monochannel telephone dialer User manual 24 4 7 Calling cycle repeating Digit the programming code then press the 4 key 1 The display visualizes the number of times the calling phase must be repeated default 2 2 Digitanumberfrom1to9to change it After setting the number of times the calling phase must be repeated in case of alarm the dialer returns to the principal men automatically then press PAUSA ABB one time to exit from the programming GIA 4 8 Message repeating ED Digitthe programming code then press the 7 key 1 The display visualizes the number of times the message must be ELE repeated for each call default 2 x 2 Digitanumberfrom 1to 9 to change it After setting the number of times the message must be repeated the dialer returns to the principal men automatically then press PAUSA ABB to exit from the programming Operating 25 Monochannel telephone dialer User manual A A 4 9 Dialling visualization during the callings ED Digitthe progra
6. alization storing number Big GA Operating 4 4 Telephone numbers variation Digitthe programming code then press the 1 key U Is visualized 1 corresponding with the 1st of 10 numbers The point in the corner on the right of the display indicates INV Blinking empty position no stored number Visualization iv it storing Fix full position stored number number Press a number from 1 to 0 corresponding to the telephonef Digit AR new Visualiz number to vary number ei Press INVIO The telephone number will be immediately displayed It needs pressing INVIO again during the telephone number visualization to overwrite it Digit the telephone number Press INVIO Press PAUSA ABB two times for exit 21 Monochannel telephone dialer User manual 22 4 5 1 2 3 Press PAUSA ABB one time to return to the point 1 or two times to Telephone numbers cancelling Digitthe programming code then press the 1 key Press the corresponding key to the number to cancel Press INVIO Press INVIO to cancel exit from the cancelling phase GIA 0 0 av NV GIA 4 6 4 1 Message listening Digit the programming code then press the 3 key Press
7. ance on CIA products 1 1 Description of the telephone dialer This device satisfy the users needing a system that in case of alarm calls them on a portable telephone or at the office or wherever a telephone is present The monochannel telephone dialer allows to send by the traditional telephone line a vocal message of 24 seconds at the most toward 10 different users The activation is made by a positive tension pulse 13V from a burglary system or for tele help service from a remote control GIA Introduction 1 2 Operating features Numeric display 10 telephone numbers storing Max capacity up to 24 digit for each telephone number Possible insertion of pauses during the telephone number Built in microphone for vocal message digital recording Maintenance of the stored message without power supply Loudspeaker for listening the recorded message and for test function monitoring Message duration up to 20 sec Decadical Pulse or multifrequency DTMF dialling selection Personal code for acces to the programming test functions Test function for message sent to a single stored telephone number Telephone line protected by transient absorption zener Monochannel telephone dialer User manual 1 3 Technical specifications Operating voltage Absorption in st by Absorption during alarm Absorption during programming Weight e Dimensions DEAN 13V 5 45mA 70mA 130mA 635g CT81 423g TD81 463g
8. m the numbers recording phase or two times to exit from the programming Programming Ben D 6 8 15 Monochannel telephone dialer User manual A A 3 1 3 Pulse DTMF setting ED Digitthe programming code then press the 5 key Nn e LI 4 1 Isvisualized 0 or 1 Press 0 to enable the decadic composition Pulse or press 1 to enable the multifrequency composition After setting the kind of composition the telephone dialer returns to 1 the principal men automatically then press PAUSA ABB one time to i exit from the programming 16 GIA 3 2 Alarm test CD Digitthe programming code then press the 0 key 1 Digit the choosed telephone number from 1 to 0 for the TEST on the telephone line Itis advisable to call to a cellular telephone 2 Press INVIO The display visualizes all the calling phases it sends the message and it sets in stato di STAND BY indicated by a fix down the display Connection with the telephone line L Telephone number dialing for the test enabled Waiting Message sending End of connection Programming I L Composition of numbers de D ma D 17 Monochannel telephone dialer
9. mming code then press the 8 key 4 4 i 4 1 Press 1 to enable the dialer state visualization during the callings G J phases or press 0 to disable it x The dialer returns to the principal men automatically then Wi RE itato press PAUSA ABB one time to exit from the programming 26 GIA 4 10 Programming code changing 1 Digitthe new code 4 digits 2 Press PAUSA ABB two times ED Digitthe programming code then press the 9 key Operating 27 Maintenance 5 Maintenance 5 1 Cleaning e Forthepanelcleaning use only a soft and humid cloth e Nousingabsolutely diluents and abrasive sponges 5 2 Default values settings in factory Digit the programming code then press the 6 key 1 Press the 8 key 2 Press the 2 key 28 GIA ED t 260DE 1 00
10. rs changing It allows the telephone numbers introduction changing visualization cancelling ER Message recording It allows the two vocal messages recording ER Message listening It allows to listen again the two recorded vocal messages B Cycles repeating It allows to set the number of callings cycles in case of alarm default 2 11 Monochannel telephone dialer User manual a cA ED Pulse DTMF It allows to set the decadic Pulse or multifrequency DTMF numbers dialing selection DB Default values restoring It allows to reset the original factory values GEB Message repeating It allows to set the number of times that the vocal message must be repeated for each call default 2 RR Numbers dialling selection visualization It allows to enable or disable the telephone number dialling visualization during the calling cycles default 1 enabled EB Code changing It allows to personalize the access code to the programming phases D TEST It allows to make a TEST by the dialing of one of the stored telephone number and the vocal message playback The phases 1 2 and 5 are necessary to enable the dialer 12 GIA Programming 3 1 1 Telephone numbers introduction ED Digitthe programming code then press the 1 key 1 Isvisualized 1 corresponding with the 1st of 10 numbers as The point in the corner on the right of the display indicates
11. trusion and anti aggression systems e The telephone dialer panel TM81P has to be installed in the upper side of a TM2 TM3 or TM4 box by the two screws in endowment It is also possible to install the telephone dialer panel togheter with a burglary centrale unit panel In that case is necessary to use the TM4C box GIA Installation 2 2 Terminal board description 12345 6 7 8 91011 1 GND Ground connection 2 3 LINE Main telephone line input 4 5 PHONE Telephone line output to connect to the phones 6 Input ON Enabling of the telephone dialer by positive 13V 7 Input A Activation of the telephone dialer by positive pulse 13V 8 9 13Vcc Power supply 13V 5 9J NEGATIVE 10 POSITIVE 10 11 TAMPER Protection tamper to connect in series to the 24h line of the burglary system Monochannel telephone dialer User manual A cA 2 3 Connections diagram telephone line BURGLARY CENTRAL UNIT In series to the 24h line of the burglary system 10 GIA Programming 3 Programming 3 1 Programming phases To enter the programming it needs dialing the access code 1 2 3 4 setted in factory or Li pressing the RESET key inside ofthe telephone dialer The display indicates the main men Fa It is possible to enter the different programming phases pressing a number from 0 to 9 ATTENTION the programming phase ends after one minute of inactivity x B Enabling numbe