User Manual Airwing Compact Dual Motor
Contents
1. Canada PH 1 7804354951 Fax 1 7804354955 daniel blueleafhealthcare com
2. Compact Lift Chair Twin Motor Operating Instructions amp Service Manual comfort INDEX Specifications Important Safety Precautions amp Set up Operating Instructions Castors amp Battery Backup Air Comfort Seating System Service amp Maintenance Warranty Service Contract MAXIMUM USER WEIGHT DIMENSIONS GROSS WEIGHT OF CHAIR CONSTRUCTION ACTUATORS CASTORS POWER SUPPLY SPECIFICATIONS Length Seated Position 820mm _ 820mm rs RE es RE ack Height eat Depth 430mm 510mm 910mm eat width 500mm 500mm l600mm eat Height 440mm 520mm 520mm 65kg Timber framework Steel Lift Mechanism Patented Air Comfort Seating System Foam amp fabric cover 18 Volt Electric 50mm black rubber swivel castors 2 locking 2 standard 100 240 V AC 50Hz IMPORTANT SAFETY PRECAUTIONS e This product has been designed and manufactured with safety and function for both the user and the operator as the utmost importance The recommended max load capacity for this product 1s 120kg e Operators must read and follow the manual to ensure all safety precautions are not compromised e For safety when lowering the product to its lowest position the operator should ensure any obstructions are removed from behind e When fully reclining the back on a twin motor mechanism the chair should be positioned a minimum of 450mm distance from a rear wall e For safety transferring a patient
3. d with a damp cloth and then wiped dry After some time lubrication of joints and pivot points can assist Common Service Concerns l The transformer is overheating and the lift and recline action is not operating This usually indicates that one of the cords inside the action has been damaged or cut Contact your dealer to arrange a repair This damage is not a covered under warranty There isn t enough air in the seat If you are unfamiliar with the Air system it may appear that there is not enough air in the air bags The air bladders work effectively when the user is sitting in the chair When seated the small amount of air will displace throughout the bladders to create a thin layer of air cushioning Do not add air to the bladders before first consulting your supplier or the manufacturer If you believe one of the air bladders has deflated un velcro the cover on the side of the seat to access and carefully remove the problem bladder Examine the bag and the valve for obvious punctures or any sign of damage particularly along the welds To test for a leak inflate the bag making sure the valve is then properly secured and leave it aside for several hours or overnight to see if it deflates of its own accord Ifthe bladder shows signs of leaking air a new bladder can be sourced through the supplier from whom the unit was purchased Should you wish to repair the air bladder onsite puncture kits are available Follow the instructions on th
4. e puncture kits for repairing the leak The seat area has collapsed Do not be alarmed when the seat settles into its natural shape The seat should look slightly concaved after some time as the foam settles This does not necessarily indicate that the air bladders are faulty Sit in the unit and you will find that the cushioning is unchanged or in fact improved If you still feel the air bladder has a leak follow the steps outlined in point 2 above WARRANTY SERVICE CONTRACT Warranty Frame Foam Air Bags Castors Fabric Workmanship 5 Years 5 Years 2 Years 2 Years Manufacturers 2 Years Conditions Apply See Warranty for further details Service contract A Hills Healthcare Technical Representative should service the product annually Please contact your place of purchase for warranty claims or service contract enquires We appreciate any feedback regarding Air Comfort products or service Supplied by Australia Hills Healthcare 128 Milperra Rd Revesby NSW 2212 PH 612 97715988 Fax 612 97743515 sales hillshealthcare com au New Zealand WS Medical 16 Heaton Grove Birkenhead Auckland New Zealand PH 64 94198371 Fax 64 94198341 don wsmedical co nz Europe Apollo Healthcare Unit 11 29 30 Horse Fair Banbury Oxfordshire OX160BW United Kingdom PH 44 7855332756 sales apollo healthcare com Canada Blueleaf Healthcare Unit 3 6104 82 Ave Edmonton Alberta
5. eg rest can be raised and the back reclined for further comfort The twin motor allows each of these functions to be operated independently or in unison e When fully reclining the back on a twin motor mechanism the chair should be positioned a minimum of 450mm distance from a rear wall Handset The diagram below identifies which button on the handset operates which function of the chair e The handset is spill resistant however avoid contact with liquids as a precaution The handset is not waterproof and must not be washed or immersed in liquid Raises Lowers backrest backrest Twin Motor Compact Lift Full Recline position Lowers footrest Lowers chair amp amp lifts chair raises footrest Lifts chair Lowers chair amp backrest amp backrest together together Twin Motor Compact Lift Full lift position CASTORS All Compact Lift Chairs are fitted with four swivel castors The two rear swivel castors are also locking To lock the castors simply push the side lever down where marked ON To unlock the castors push the same lever down on the opposite end marked OFF Swivel Locking Castor Swivel Castor BATTERY BACKUP The battery backup feature enables the lift chair to be powered to the raised position once only in the event of a power failure 2 x 9v batteries are fitted to the compartment inside the transformer The batteries must be replaced if the lift chair has been operated dur
6. ing a power failure or operated when unintentionally not plugged into AC power 2 x 9 Volt Batteries AC DC Switching Power Supply Pp Ma Vente tn SN AAT Hatha MM s ke h jn i A J 4 4 I AIR COMFORT SEATING SYSTEM The Exclusive Air Comfort Seating System is comprised of four separate air bladders providing complete head to toe pressure relief and superior comfort Each Bladder is filled with a specifically calibrated low level of air to ensure maximum pressure relief for the average user There should be no need to adjust the level of air or access the bladders unless to fulfill a specific clinical need and at the direction of a Clinician or if there appears to be a fault All Air Comfort models are extensively pressure mapped during research and development to identify the ideal air levels construction and materials Compact Lift Seat Pressure Map 30 Mins Measurement mmHg SERVICE amp MAINTENANCE Maintenance and Cleaning l Cleaning Instructions e Material Please follow specific fabric cleaning instructions located on the rear backrest cushion e Electrical components and cables The handset transformer cables and actuators should be regularly inspected cleaned and replaced if found to be damaged Failure to immediately replace damaged components can result in damage to other connected electrical components e Lift Action The steel lift action should be regularly cleane
7. on off the chair the operator must ensure that the rear castors have been locked e Never have any loose objects in the vicinity of the product when using any of the functions as these may obstruct hinder or damage the moving components of the product Always check the surrounding area and under the chair for objects that may be crushed with any movement of the product e Do not place anything over the power cords pass any power cords through the chair or drag the chair by the cords When positioning ensure all cabling is free of the mechanism Damaging the electrical cables voids the warranty e Ensure electrical plug is disconnected from the wall before moving the product e Do not use as a CPR Bed e When not in use leave the product in the upright position e Follow the maintenance instructions e Follow the cleaning instructions SET UP INSTRUCTIONS The product 1s delivered fully assembled and ready for use however inspect the product before use For protection the transformer and power cable are stored behind the backrest cushion Transformer power cord and cable can be found tucked behind the bottom of the lumbar cushion OPERATING INSTRUCTIONS Positioning The Air Comfort Compact Lift Chair Twin Motor is fitted with two electric actuators Using a handset this allows the occupant or carer to gradually lift the chair at an angle to assist the occupant to sit or alight from the chair Using the same handset the l