Astor 800/D - Astor 900/D Waterbath User`s Manual

image

Contents

1. Astor 800 D Astor 900 D Waterbath User s Manual ASTOR 900 D Distribu par LABORATOIRES HUMEAU Z A de Gesvrine 4 rue K pler B P 4125 44241 La Chapelle sur Erdre Cedex France t 33 0 2 40 93 53 53 f 33 0 2 40 93 41 00 e info humeau com D Fa w w w h u m e a u CcC 0o m Astor 800 D Astor 900 D Waterbath User s Manual WARNINGS ssaa aaa 3 GENERAL DESCRIPTIONS ia 3 ELEGIRIGALCONNEGHOM urnas 3 INSTRUCTIONS celiaca ico I Te on anne 3 FEATURES Rai alice 4 SAFE DEVIGES acacia 4 DOCUMENT VALIDITY asa 4 TECHNICAL SERVICE la 4 EXTERNAL STRUCTURE CLEANING ida 5 DISPOSER en ne ippo Donne 5 PICTURES OF TRE EQUIPMENT leo 6 CE DECLARATION OF CONFORMIT asia id 7 WARNINGS Before using the equipment read this user guide This manual is an integral part of the product and must be conserved for future consultation In it you can find important information regarding safety of use and maintenance Read carefully the instructions contained in this manual before installing operating and performing adjustments or maintenance operations Even if this device is provided with protections the use of the equipment without following the described procedures could produce a wrong working and damages on the equipment The manufacturer is not liable for damages to people or things caused by improper use of the equipment and or not respect of laws regulations and instructions described below GENERAL DES
2. CRIPTION ASTOR 800 D thermostatic unit from 5 over the room temperature up to 100 if the unit is used in a bath without a lid the maximum thermostated temperature can be up to 90 only ASTOR 900 D waterbath from 5 over the room temp erature up to 99 9 Structure in aluminium fire painted Temperature control by means of an electronic thermalregulator with digital setting and reading which shows the temperature value with a decimal unit Safety device against the over temperatures of the resistors due to the lack of water inside the bath ELECTRICAL CONNECTION Check the power voltage as stated on the platelet of the equipment it must be identical to the power supply the equipment will be connected to Verify the presence of the ground connection and be sure the power supply is protected by means of the safety devices as described in the valid European laws we suggest the use of a life saving device with a trip power supply of 0 03 Ampere IAN 0 03A The manufacturer will not be responsible of any damage to people or things due to the lack of respect of these instructions In case the equipment cannot be plugged in because of an unfitting electrical connection we suggest to substitute it with an appropriate kind of plug by qualified personnel We suggest to avoid the use of adapters multiple plugs electrical connections and additional electrical cables INSTRUCTIONS Fix the unit to the bath by
3. f the above written company hereby declares that the above mentioned goods are in compliance with the following directives 2004 108 CE ex 89 336 CEE and 2006 95 CE ex 73 23 CEE and the normatives EN 61326 1 EN 55014 1 EN 60335 1 EN 60335 2 73 Poncarale anno year 09 ASTORI TECNICA Snc Fagotti dr Giovanni pan
4. locking the knob Astor 800 D only Connect the waterbath to the socket Turn the equipment on the thermalregulator is off and the resistor does not heat whereas the liquid stirrer is working Fill the bath with deionized water till the display turns on Fill the water again as to raise the water level about 1 cm more Set the working temperature on the thermalregulator by pushing the Ul coy located on the right of the thermalregulator keep it pushed no longer than 2 seconds The SET message will appear on the display Push the key once again no longer than 2 seconds and set the required temperature by means of MI and MA keys After the temperature is set push the key and the SET message will appear push 3 once again to go back to the beginning and to visualize the real temperature value in the bath on the display Pay Attention Place the thermostatic unit correctly to avoid the contact between the resistor and the bath walls FEATURES Power supply 230V 50Hz Power absorption 1000W Range of temperatures from 5 above the room te mperature up to 100 with ASTOR 800 D from 5 above the room temperature up to 99 9T with ASTOR 900 D the maximum temperature values can be kept only when the bath lid is closed This range temperature depends on the air pressure too Accuracy better than 0 5 SAFETY DEVICES The equipment is provided with two safety devices
5. other aggressive detergents to clean the equipment DISPOSAL The symbol of the crossed garbage collector indicates that the product at the end of its useful life should be collected separately from normal garbage The user will give the equipment at the end of its Usage to centers for collection of electronic and electrotechnical garbages according to rules and laws The proper collection of the disuded equipment the recycling treatment and disposal contributes to avoid possible negative effects on the environment and human health and encourages the recycling of the materials that compose the equipment Di Main switch Fuses Thermalregulator Safety thermostat Restore key Level sensor Liquid stirrer Heating resistor Safety sensor Temperature sensor O OO J O O1 D gt Dichiarazione di conformita Declaration of conformity CE Costruttore Manufacturer ASTORI TECNICA di Fagotti Giovanni amp C S n c Via Stelle n 11 25020 Poncarale BS Italy Strumento Equipment Modello Model Astor Matricola n Serial number Anno di fabbricazione Year of manufacturing 2010 Il sottoscritto legale rappresentante della ditta Astori Tecnica Snc dichiara che i prodotti sopracitati sono conformi alle seguenti direttive 2004 108 CE ex 89 336 CEE e 2006 95 CE ex 73 23 CEE ed alle norme EN 61326 1 EN 55014 1 EN 60335 1 EN 60335 2 73 The undersigned authorized officer o
6. the level sensor which stops both the thermalregulator and the power supply of the resistor when the level of water is too low the safety sensor applied to the resistor which will act by turning the equipment off when the resistor exceeds the maximum temperature value and the safety craft does not work The sensor must be restored manually after removing the cause of the problem it is necessary to push the restore key in the front side of the equipment page 6 picture 4 by means of a pointed pin DOCUMENT VALIDITY ASTORI TECNICA reserves the right to review and modify this document without any notice any variation will not affect the respect of the directives TECHNICAL SERVICE If the equipment does not work verify that The level of water rises the safety craft The plug of the instrument has been correctly placed in the electric socket The automatic main power supply switch of the laboratory is not in OFF position An electric black out is not occurring All the keys are not wrongly activated The fuses are not broken The safety thermostat placed in the front of the equipment is not in OFF position When the Service Assistance is needed please communicate the serial number of the equipment EXTERNAL STRUCTURE CLEANING Before the cleaning operations remove the plug from the socket Use a wet towel and do not pour water on the equipment Clean the equipment with a neutral detergent Do not use alcohol or