Home

ACS350 series brochure

image

Contents

1. MREL 01 ACS350 has one relay output as standard The optional MREL 01 module offers three additional relay outputs which can be configured for different functions with parameters MTAC 01 The optional MTAC 01 module offers pulse encoder interface for speed measurement Protection and installation NEMA 1 UL Type 1 kit The NEMA 1 UL Type 1 kit includes a connection box for finger protection conduit tube installation and a hood for protection against dirt and dust Terminal cover The terminal cover is for protection of the I O connections Clamping plates The clamping plates are used for protection against electrical disturbances The clamping plates with clamps are included in the drive package as standard 3AFE68596106 REV G EN 25 8 2009 11 12 Options Software tools A separate order line and type code is required for any of these software tool options DriveWindow Light 2 DriveWindow Light 2 is an easy to use start up and maintenance tool for ACS350 drives It can be used in an offline mode which enables parameter setting at the office even before going to the actual site The parameter browser enables viewing editing and saving of parameters The parameter comparison feature makes it possible to compare parameter values between the drive and saved parameter files With the parameter subset you can create your own parameter sets Controlling of the drive is naturally one of the features in DriveWindow
2. 03X 03A5 2 ACS CHK B3 ACS CHK B3 ACS CHK C3 ACS CHK C3 ACS CHK C3 NOCH 0016 6x NOCH 0016 6x NOCH 0030 6x 03X 31A0 2 NOCH 0030 6x 03X 46A2 2 R4 NOCH 0070 6x 3 phase supply voltage 380 480 V units osxoraza Ro ACS CHKBS o osxorasa Ro ACS CHKES 6o aos oHkeBa mo acsomkes 10 ACS CHK C3 10 acs 0Hios 100 NOCH oo16 6x_ 100 nochor 10 osx 1zas 4 R3 NOCH O01G 6x 10 oaxasasa RS NOGH O016 6x 10 oaxezaa1 a Ra NocHo080 6 10 nocHoosoes 10 gt NocH 0030 6x 100 NOCH 0030 6x 100 03X 09A8 2 03X 13A3 2 03X 17A6 2 ABB Options External A separate order line and type code is required for any of these external options The ACS350 s internal EMC filter is designed to meet category C3 requirements of EN IEC 61800 3 standard External EMC filters are used to enhance the drives electromagnetic performance in conjunction with its internal filtering Maximum motor cable length depends on required electromagnetic performance according to the table below 1 phase supply voltage 200 240 V units xosa 60 am 10 30 2 3 Rena 10 30 so 30 so Rema 10 30 so 30 so forxo7as2 ma mera 10 30 so 30 so forxcoons 2 ra mera 10 30 so 20 so xoana Ro erse 10 0 2 30 foax oaas 2 Ro mers2 10 30 30 20 rrrvez 10 30 so a0 so Parvez 10 30 so 30 so rrrvez 10 30 so a0 50
3. 168 187 1 6 r2 160202 230 106 165 191 15 267 282 105 168 191 19 ma 105202 264 200 1609 195 44 J2ro o20 200 177 195 5 0_ H Height H5 Height with fastenings NEMA 1 H1 Height without fastenings and clamping plate connection box and hood H2 Height with fastenings but without clamping plate W Width H3 Height with fastenings and clamping plate D1 Standard depth H4 Height with fastenings and NEMA 1 connection box D2 Depth with MREL or MTAC option 8 3AFE68596106 REV G EN 25 8 2009 ABB Options a The options shown in the table are available within the ACS350 range The ordering code which is shown in the second column replaces the A123 in the type code above You can order as many options as required simply by extending the code as necessary s EAN a EAN CC LI CI IC CO TEEN O CIO L Panel mounting kit Panel mounting kit ACS H CP EXT CI ee Panel holder mounting kit OPMP 01 a eee f Y l wer fomo CC o fo s mos a o o C CU a A a D A Extension modules AE Speed encoder module MTAC 01 BARE Connection options C IAN ACI LL a TS AS ee EN ra pa DriveWindow Light 2 DriveWindow Light 2 IN o ce A O standard E product variant O option external not available 7 Ordering with a separate MRP code number 1 Option not available with NEMA 1 UL Type 1 2 Options only with IP2x ABB 3AFE68596106 REV G EN 25 8 2009 9 10 Options E
4. loba b Te ae Ge Ge Te Be Ge O tis id t di is ty rh ABB Options a External A separate order line and type code is required for any of these external options FlashDrop tool FlashDrop is a powerful palm sized tool for fast and ACS350 is delivered with an integrated brake chopper easy parameter selecting and setting It gives the as standard Therefore no additional space or installation possibility to hide selected parameters to protect the time is needed The brake resistor is selected using the machine Only the parameters needed in the application table below For more information about the selection of are shown The tool can copy parameters between two brake resistors see the ACS350 User s Manual drives or between a PC and a drive All the above can Brake chopper limits and resistor selection table be done without a power connection to the drive in Selection table by resistor type fact it is not even necessary to unpack the drive EE N DrivePM 160 210 260 460 660 560 time A DrivePM Drive parameter manager is a tool to create 3 1 phase supply 200 240 V units edit and copy parameter sets for FlashDrop For each xoana 70 o37 os e A parameter group the user has a possibility to hide 1X o o 75 E ae a e it which means that the drive user does not see the wre o a ste SSS parameter group at all 30 15 2 xosa 00 2
5. Light With this software tool you can monitor up to four signals simultaneously This can be done in both graphical and numerical format Any signal can be set to stop the monitoring from a predefined level Sequence programming tool DriveWindow Light 2 allows the user to visually build and manipulate sequence programming parameters that are loaded into the ACS350 The programming is done in a graphical editor which displays each sequence step as an individual block Sequence programming enables application specific programming This new and easy way to preset sequences reduces the need for an external programmable logic control PLC In simple applications an external PLC can be left out Start up wizards Start up wizards make the setting of parameters easy Simply launch the wizard select an appropriate assistant e g for setting analog outputs and all parameters related to this function are shown together with help pictures 3AFE68596106 REV G EN 25 8 2009 Highlights E Graphical sequence programming tool for ACS350 E Editing saving and downloading parameters E Graphical and numerical signal monitoring E Drive control E Start up wizards DriveWindow Light requirements E Windows NT 2000 XP Vista M Free serial port from a PC M Free control panel connector o CAS DO Too Coni Uno D page e O ecr san o E i alx BPP Gee Bis ta zi RE te gt SO ES El Egat Fssi
6. SO0iz Rated output current l n 1 5 X fon for 1 minute every 10 minutes At start 1 8 x Lon for 2 s 4 kHz 4 to 16 kHz with 4 kHz steps 0 1 1600 0 1 1600 Inbuilt brake chopper as standard 20 of motor nominal slip lt 1 s with 100 torque step lt 10ms with nominal torque 5 with nominal torque 10 to 40 C 14 to 104 F no frost allowed 50 C 122 F with 10 derating Rated current available at O to 1000 m 0 to 3281 ft reduced by 1 per 100 m 328 ft over 1000 to 2000 m 3281 to 6562 ft Lower than 95 without condensation IP20 optional NEMA 1 UL type 1 enclosure IP66 IP67 UL Type 4X as an option up to 7 5 kW IP69K available for IP66 IP67 variant with compatible cable glands NCS 1502 Y RAL 9002 PMS 420 C IEC721 3 3 No conductive dust allowed Class 1C2 chemical gases Class 182 solid particles Class 2C2 chemical gases Class 2S2 solid particles Class 3C2 chemical gases Class 382 solid particles Product compliance Low Voltage Directive 2006 95 EC Machinery Directive 2006 42 EC EMC Directive 2004 108 EC Quality assurance system ISO 9001 Environmental system ISO 14001 UL cUL CE C Tick and GOST R approvals ROHS compliant ABB Two analog inputs Voltage signal Unipolar Bipolar Current signal Unipolar Bipolar Potentiometer reference value Resolution Accuracy One analog output Auxiliary voltage Five digital inputs Input impedance One relay o
7. o1xo7as2 R2 _ 2026 ga so ULclassT Facseso orx o0n8 2 R2 2535 ge 06 ULclassT 3 phase supply voltage 200 240 V units ACS350 03X 03A5 2 gG 10 ULclassT gG 15 ULclassT Fl ga 20 ULciass T G UL class T UL class T UL class T UL class T UL class T cepet ACS350 03X 09A8 2 ACS350 03X 13A3 2 ACS350 03X 1 7A6 2 Pe og ACS350 03X 31A0 2 ACS350 03X 46A2 2 3 phase supply voltage 380 480 V units ACS350 03X 01A2 4 ACS350 03X 01A9 4 G G g g g g gG G Q eae Pus ACS350 03X 12A5 4 ACS350 03X 15A6 4 ACS350 03X 23A1 4 UL class T UL class T UL class T gG gG gG PPP Re X within the type code stands for E or U According to IEC 60269 standard If 50 overload capacity is needed use the bigger fuse alternative ABB Control connectio ns The diagram below gives an overview of ACS350 control connections and shows the default I O connections for the ABB standard macro ACS350 has seven standard macros and three user macros Please refer to the ACS350 User s Manual for more detailed description of each macro Control panel RJ 45 Modbus RTU RS 232 S da max 500 ohm Output frequency speed AO E A Output frequency reference O 10 V Fi I O 20 mA Analog input circuit common GND o ct Analog output circuit common Reference voltage 10 V DC max 10 mA Not in use by default Analog input circuit c
8. 2 0 Je 4 3 phase supply voltage 200 240 V units se aides meena oxo 70 osr os Je T T T e indows ista ee E Free serial port from a PC CA A T FlashDrop package includes Ea E FlashDrop tool a E E DrivePM software on a CD rom os M User s manual in English and in pdf format on the ARETES CD rom psp ppp E Cable OPCA 02 for connection between the PC and e E 2 FlashDro p tool 3 phase supply voltage 380 480 V units M Battery charger A A tet oto A A A A IES a A i 7 jesxaras s 70 3 N NJ k NJ Feces o 1 CEE 22 pC E COn X within the type code stands for E or U 1 Braking time Maximum allowed braking time in seconds at Permax every 120 seconds at 40 C ambient temperature Ratings by CBR V CBR V ee V pre V pe V ae V resistor type 160 210 E 60 EA ABB 3AFE68596106 REV G EN 25 8 2009 13 14 Options External A separate order line and type code is required for any of these external options Ce EEES Input choke smooths the wave shape of mains current and reduces total harmonic distortion THD Together with the input choke the ACS350 is designed to fulfill the requirements of the harmonics standard EN IEC 61000 3 12 In addition the input choke provides improved protection against mains voltage transients 1 phase supply voltage 200 240 V units oncozas 2 Ro Jom 61 45 5 80 omar ma 81 10 28 omeci 161 mo te 12
9. Catalog ABB general macninery drives ACS350 0 37 to 22 KW 0 5 to 30 hp Power and productivity Ah ED AR for a better world PA ED Lb Two ways to select your drive ES Choice 1 Simply contact your local ABB drives O B Choice 2 Build up your own ordering code using sales office see page 19 and let them know what the simple 7 step approach below Each step is you want Use page 3 as a reference section for accompanied by a reference to a page that is filled more information with useful information Type code stucture ACS350 0244 a 2 L 2 3 8 LJ An bye ene Ee Vi a Tages Construction Dimension Options Contact and web information 2 3AFE68596106 REV G EN 25 8 2009 ABB Contents E ABB general machinery drives ACS350 Con SUR WIG MC a a In Dmmensions a a eee te ee eee ee 8 Cabinet mounted CriVeS mreka raen ken ana 8 Wal MUI Arves ae ee a a ee ee eee 8 PR mnynelainmengniainanacas Snares 9 POW tO E Soera eae eee 9 WISER ILE ACES arts RAN Mia es o anh ae 10 Macame Imtenao st a po e ii Extension MOdUES e tase ee e o 11 Protection o Ta Drive window Cont 2 aee a gene tes sheath 12 asii e cen e aretCner a a 13 Brake MESSI See anea a eee ene To Mpu and Omnu CNokeS a eace ence 14 A creek cece ete ea etek he ta 15 Low leakage current filters oo ooommom o 15 ANN ADO CON ies ere ee ee eee ec 19 ABB 3AFE68596106 REV G EN 25 8 2009 3 4 ABB ge
10. J Interfaces Panel cover i The purpose of the panel cover is to protect the drive s 1 as nus s gt connection surfaces The ACS350 drive is delivered with a panel cover as standard In addition there are two alternative control panels available as options Basic control panel The basic control panel features a single line numeric display The panel can be used to control the drive set the parameter values or copy them from one drive to another Assistant control panel The assistant control panel features a multilingual 4 R e l E Basic control panel alphanumeric display for easy drive programming u l The control panel has various assistants and an inbuilt a help function to guide the user It includes a real time Ma A clock which can be used during fault logging and in Pand gover controlling the drive such as start stop The control included as standaro panel can be used for copying parameters for back up or for downloading to another drive A large graphical display and soft keys make it extremely easy to navigate The drive with IP66 IP67 enclosure has the assistant control panel as standard c A Potentiometer Assistant control panel Potentiometer Potentiometer MPOT 01 with two switches start stop and forward reverse Polarity is selected with DIP switches No external power source is needed for the potentiometer Panel mounting kits To attach the control panel to the outside of a large
11. est possible cost while the entire value chain from the moment a customer maintaining the highest quality end products One of makes the first enquiry through to disposal and ABB s key objectives is to maximize the uptime of its recycling of the drive Throughout the value chain customers processes by ensuring optimum lifetime of ABB provides training and learning technical support all ABB products in a predictable safe and low cost and contracts All of this is supported by one of the manner most extensive global drive sales and service networks Maximizing return on investment At the heart of ABB s services is its drive lifecycle precisely the timing of the part replacements plus all management model All services available for ABB low other maintenance related actions The model also voltage drives are planned according to this model For helps the customer when deciding about upgrades customers it is easy to see which services are available retrofits and replacements at which phase Professional management of the drive s lifecycle Drive specific maintenance schedules are also based maximizes the return on any investment in ABB low on this four phase model Thus a customer knows voltage drives ABB drive lifecycle management model The drive with complete lifecycle The drive with complete lifecycle services is available for purchase services is available for plant extensions kk Complete lifecycle services To ensure
12. foax oons 2 Re mersz 10 20 so 30 so foax taaa 2 ra meso 10 20 s0 30 50 foax i7as 2 Ra meso 10 30 so 20 so menos 10 30 so a0 so foax stao 2 pa meras 10 30 so 30 so foax acaz 2 pa meros 10 20 50 30 so foax oraz a mo erse 90 30 2 30 foax orae a Ro Rese 90 30 20 30 rrrvez 50 so so a0 50 Parvez 50 so so 30 so Rea 50 so so a0 50 Rea 50 so so s0 so Rea 50 so so a0 s Parvez 50 so so 30 so foax i2as a mo rras 40 40 40 30 so foaxcisas a Ra meso 40 40 lt 0 30 50 foax zaat a mo meso 40 40 40 20 50 Resa of 30 50 menos a0 20 50 meros ao 30 oso 1 Internal EMC filter must be connected with the EMC screw in the drive When the filter is not connected the C4 maximum cable lengths are allowed to be used ABB Low leakage current filters are ideal for installations where residual current devices RCD are required and leakage current needs to be below 30 mA Low leakage current filters 3 phase supply voltage 400 V units 03X 01A2 4 LRFI 31 o tar osons mo meros DIN IC DCI IN DIN to DONT IN mera tO 1 Internal EMC filter must be disconnected by removing the EMC screw from the drive EMC standards in general Category C1 Group 1 1 environment Class B unrestricted distribution Category C2 Group 1 1 environment restr
13. forxo7as 2 R2 cHK ci 168 12 16 12 oncosas 2 R2 omo 21 15 25 10 3 phase supply voltage 200 240 V units fosx o2aa 2 mo cmo as 22 42 oa joax oaas 2 Ro CHK 02 61 36 76 as Comicos 76 48 13 27 cuicos ma 72 18 27 Comicos 12 62 22 15 osxosas 2 R2 chicos 143 n 2 15 fosx isas 2 m2 cHK o4 217 14 22 lis joaxa7ae 2 R2 chicos 208 18 22 15 onoo n 27 ar oz gt josx stao 2 ma chos so s az 07 fosx a6a2 2 a cHK o6 69 ar 47 o7 3 phase supply voltage 380 480 V units fosx o1az 4 mo cmo 22 14 42 64 josx orae a Ro cmko 36 23 42 64 cmko 139 es 13 27 foox2as 4 Re omios 18 18 18 27 fooxsa6 4 Re omios 21 18 22 1s fosx 20at 4 Re omicos 009 2 22 15 cmko s2 ss ss ta eko 61 ar o7 hn Nominal input current an Nominal choke thermal current L Choke inductance 3AFE68596106 REV G EN 25 8 2009 Output choke decreases du dt on the output and filters current spikes caused by voltage spikes With an output choke it is possible to increase the motor cable length which could be otherwise limited due to a temperature increase resulting from current spikes and electromagnetic performance 1 phase supply voltage 200 240 V units 01X 02A4 2 ACS CHK B3 ACS CHK B3 ACS CHK C3 01X 07A5 2 ACS CHK C3 01X 09A8 2 ACS CHK C3 3 phase supply voltage 200 240 V units 03X 02A4 2 ACS CHK B3
14. g THD in partial loads and to comply with EN IEC 61000 3 12 External option To achieve longer motor cables 3AFE68596106 REV G EN 25 8 2009 ABB general machinery drives E ACS350 IP66 and IP66 _Acs350 02a4 2 01E High protection class drive 3 phase 200 to 240 V 10 0 37 to 4 kW 0 5 to 5 hp 3 phase 380 to 480 V 10 O87 107 5 kv 05 to 10 hip A range of ABB general machinery drives with IP66 and IP67 protection classes is designed to excel in the harshest and most demanding of conditions Designed for the food and beverage textile ceramics pulp and paper and water and waste water industries the drives are suitable for screws mixers pumps fans and conveyers especially where the machine is exposed to dust moisture and cleaning chemicals The heat sink s cooling fins are completely open from top to bottom which allows easy washing to ensure no dirt adheres to the surfaces A user control panel housed within a plastic window is designed to resist moist and dusty atmospheres Furthermore the cooling fan is located inside the drive thereby eliminating the need for an external cooling fan and the subsequent maintenance of external moving parts The drive s hygienic design and use of materials meeting current hygiene standards means that the drive traps no bacteria and can withstand frequent washing The drive is certified by NSF The drive is designed for fast installation parame
15. icted Class A distribution Category C3 Group 2 2 environment Class A unrestricted distribution Category C4 Not applicable 2 environment restricted distribution 3AFE68596106 REV G EN 25 8 2009 15 16 Technical data ACS350 is fitted with cooling fans as standard The cooling air must be free from corrosive substances and must not be above the maximum ambient temperature of 40 C 50 C with derating Heat dissipation from IP66 IP67 drive equals to the IP20 values For more specific limits see the Technical specification Environmental limits in this catalogue Cooling air flow 1 phase supply voltage 200 240 V units ACS350 03X 09A8 2 ACS350 03X 13A3 2 acsaso oax r7as2 me 180 68 62 a1 acsaso osx stao 2 R4 328 1mo 96 57 acsaso o3xasaz2 R4 488 1666 96 57 3 phase supply voltage 380 480 V units acsaso oax o1ae a Ro a 138 MESA l 3 433 24 1 Tacseso oax 12as 4 Re 161 on se o Tacsaso oax 1sa6 4 Re 204 oor se o Tacseso oaxzear a ro 001 1020 n a2 X within the type code stands for E or U Frame size RO with free convection cooling Free space requirements 3AFE68596106 REV G EN 25 8 2009 Standard fuses can be used with ABB general machinery drives For input fuse connections see table below Selection table 1 phase supply voltage 200 240 V units ACS350 01X 02A4 2 RO 10 gG 10 ULclassT racsaso
16. ldbus adapters The most common High speed communication with compact and robust fieldbusses are available fieldbus design Inbuilt EMC filter EMC filter complying with IEC EN 61800 3 as standard No extra space parts time or cost required Drive protection Motor output and I O protected against wiring faults Latest solutions to protect the drive and offer trouble Protection against unstable supply networks free use and the highest quality Coated boards included as standard 3AFE68596106 REV G EN 25 8 2009 ABB Technical specification A d AT Mains connection Programmable control connections Voltage and power range Frequency 1 phase 200 to 240 V 10 O37 102 2 KW 0 5 OS Np 3 phase 200 to 240 V 10 O 37 to 11 KV 0 5 to 15 hp 3 phase 380 to 480 V 10 0 37 to 22 kW 0 5 to 30 hp 48 to 63 Hz Motor connection Voltage Frequency Continuous loading capability constant torque at a max ambient temperature of 40 C Overload capacity at a max ambient temperature of 40 C Switching frequency Default Selectable Acceleration time Deceleration time Braking Speed control Static accuracy Dynamic accuracy Torque control Torque step rise time Non linearity Environmental limits Ambient temperature Altitude Relative humidity Degree of protection Enclosure colour Contamination levels Transportation Storage Operation 3 phase from O to Usuppiy O16
17. neral machinery drives E ABB general machinery drives ABB general machinery drives are designed for ABB general machinery drives are designed to meet machine building In serial type manufacturing the requirements of an extensive range of machinery the consumed time per unit is critical The drives applications The drives are ideal for food and are designed to be the fastest drives in terms of beverage material handling textile printing rubber installation setting parameters and commissioning and plastics and woodworking applications The basic products have been made as user friendly drives offer diverse functionality to cater for the most demanding needs E Unified height and depth E Convenient installation E Optimized interfaces for users and machines E Impressive software and compact hardware E Sequence programming E High ingress protection IP66 IP67 UL Type 4X variant as an option E FlashDrop tool for fast parameter setting FlashDrop tool Faster and easier drive set up and commissioning for Fast safe and trouble free parameter setting without the volume manufacturing and maintenance The FlashDrop need to power up the drive tool enables both downloading and uploading drive Patented parameters Software Excellent performance with exceptional flexibility Quick and intuitive commissioning Software features include application macros timed functions and fault history Fieldbuses Enclosed plug in fie
18. ommon Aux voltage output 24 V DC max 200 mA A t P o GND PROGRAMMABLE RELAY L VORIO DUE COMMON ROCOM AND DIGITAL OUTPUTS Digital input common o DCOM wl RONC Relay output gt Stop Start f mn 9 250 V AC 30 V DC 2 Arms PE ue RONO ul 9 Forward Reverse DI2 Q Oo H DOSRC S m 2 Constant speed selection r A DIS S Mg j f DOOUT Digital output PNP transistor type L D a K a 209 Constant speed selection Q DI4 jad 30 V DC max 100 mA OSE oS DOGND OSa E Acceler and a o DIS a AZE deceler selection 1 1 DI5 can also be used l as a frequency input EMC amp EMC filter grounding screw VAR amp 2 Varistor grounding screw pe Or l i 33 UT U2 LD M 3 phase power supply L2 V1 Brake chopper V2 3 JAC motor L3 AAA w1 a a W2 la Optional brake resistor Sourcing DI configuration PNP connected with external power supply Sinking DI configuration NPN connected 24 V ACS350 X1 ACS350 X1 Ramp Const Fwd Start 9 24 pair sel Speed 1 Rev Stop 17 ABB 3AFE68596106 REV G EN 25 8 2009 Services 7 Order Installation ET gt Upgrade Replacement Pre purchase P and and and f and and delivery commissioning maintenance retrofit recycling Training and learning Technical support Contracts All industries face a common goal to maximize their The services offered for ABB low voltage drives span production output at the low
19. phase supply voltage 200 240 V units 0 37 ACS350 03X 02A4 2 ACS350 03X 03A5 2 Les E ESA A y b ACS350 03X 09A8 2 13 3 ACS350 03X 13A3 2 ACS350 03X 17A6 2 zs 10 310 acsasoosxsiao 2 Ra mo 150 462 acsaso o3x46A22 Ba 3 phase supply voltage 380 480 V units ozs 19 acsssoosxoras4 RO zs 100 156 Acssso osx t5a6 4 Rs Cmo 150 21 aosasooaxasara Rs O1E within the type code shown above varies depending on the drive phase and EMC filtering Choose below the one you need 01 1 phase 03 3 phase E U EMC filter connected 50 Hz frequency EMC filter disconnected 60 Hz frequency In case the filter is required it can easily be connected B063 IP66 IP67 UL Type 4X enclosure 3 phase supply voltage 200 240 V units 0 75 phase supply volt age 380 4 2 4 ACS350 03X 02A4 2 B063 4 7 3 5 ACS350 03X 03A5 2 B063 ACS350 03X 04A7 2 B063 ACS350 03X 06A7 2 B063 ACS350 03X 07A5 2 B063 80 V units O A fy Anh gt gt Y Ta 19Y u E 3 3 ACS350 03X 01A2 4 B063 ACS350 03X 01A9 4 B063 ACS350 03X 02A4 4 B063 ACS350 03X 03A3 4 B063 ACS350 03X 04A1 4 B063 ACS350 03X 05A6 4 B063 ACS350 03X 07A3 4 B063 ACS350 03X 08A8 4 B063 X within the type code stands for E or U 3AFE68596106 REV G EN 25 8 2009 7 Dimensions El mo 169 202 230 70 161 187 12 26r 200 70
20. r enclosure two panel mounting kits are available A simple and cost efficient installation is possible with the ACS H CP EXT kit while the OPMP 01 kit provides a more user friendly solution including a panel platform that enables the panel to be removed in the same way as a drive mounted panel The panel mounting kits include all hardware required including 3 m extension cables and installation instructions ed a MTAC 01 module Panel holder mounting kit OPMP 01 3AFE68596106 REV G EN 25 8 2009 ABB Options Interfaces gt Fieldbus module NEMA 1 UL type 1 kit e Removable clip for labeling Panel connector FlashDrop connection POWER EMC filter LEDs grounding gt screw aes EMC Analog O vane Relay output one Digital inputs sere Digital output VAR Terminal cover included as standard Clamping plates included as standard ABB Machine interfaces The plug in fieldbus modules bring connectivity to major automation systems A single twisted pair cable avoids large amounts of conventional cabling thereby reducing costs and increasing system reliabilty ACS350 supports the following fieldbus options E PROFIBUS DP E CANopen E DeviceNet E Modbus RTU M Ethernet The optional FEPA 01 module provides auxiliary power for the fieldbus module in case of a mains power interruption This module is compatible with all fieldbus modules for ACS350 Extension modules
21. ter setting and commissioning and is based on ABB general machinery drives possessing the same software features and hardware connections The drive features the assistant control panel as standard The wall mounted drive can be located close to the process and the operator 3AFE68596106 REV G EN 25 8 2009 Voltage and power range Environmental limits 10 to 40 C 14 to 104 F no frost allowed Ambient temperature Product compliance Low Voltage Directive 73 23 EEC with supplements Machinery Directive 98 37 EC EMC Directive 89 336 EEC with supplements Quality assurance system ISO 9001 Environmental system ISO 14001 CE and C Tick approvals UL and cUL pending GOST R approval ROHS compliant NSF Certified DIN40050 9 IP69K ABB Ratings types voltages and construction Type code This is the unique reference number shown above and in column 4 right that clearly identifies your drive by power rating and frame size Once you have selected the type code the frame size column 5 can be used to determine the drive dimensions shown on the next page Voltages ACS350 is available in two voltage ranges 2 200 240 V 4 380 480 V Insert either 2 or 4 depending on your chosen voltage into the type code shown above 1 phase supply voltage 200 240 V units 0 37 05 24 ACS350 01X 02A4 2 A a 6 7 20 75 ACS350 01X 07A5 2 30 98 ACS350 01X 09A8 2 3
22. the availability of complete lifecycle services a drive must be in the Active or Classic phase A drive can be kept in the Active or Classic phase by upgrading retrofitting or replacing Limited y Obsolete Spare parts maintenance and a ABB cannot guarantee availability repair services are available as of lifecycle services for technical long as materials can be obtained reasons or within reasonable cost H Limited lifecycle services Caution A drive entering the Limited or Obsolete phase has limited repair options This may result in unpredictable process downtime To avoid this possibility the drive should be kept in the Active or Classic phase ABB follows a four phase model for managing drive lifecycles which brings enhanced customer support and improved efficiency Examples of lifecycle services are selection and dimensioning installation and commissioning preventive and corrective maintenance remote services spare part services training and learning technical support upgrade and retrofit replacement and recycling 18 3AFE68596106 REV G EN 25 8 2009 ABB gt w m r Contact us my 441 024 Printed matter ABBO9_00246 2009 Ud yon O Copyright 2009 ABB All rights reserved Specifications subject to change without notice 3AFE68596106 REV G EN 25 8 2009 14412 Power and productivity AL I ED for a better world PA IE uD
23. utput Type Maximum switching voltage Maximum switching current Maximum continuous current One digital output Type Maximum switching voltage Maximum switching current Frequency Resolution Accuracy 0 2 to 10 V R gt 312 kQ 10 to 10 V Ry gt 312 kQ 0 4 to 20 MA Ra 100 Q 20 to 20 mA Rn 100 Q 10 V 1 max 10 mA R lt 10 kQ 0 19 1 O 4 to 20 mA load lt 500 Q 24V DC 10 max 200 mA 12 to 24 V DC with internal or external supply PNP and NPN pulse train O to 16 kHz 2 4 KQ NO NC 250 V AC 30 V DC 0 5 A 30 V DC 5 A 230 V AC 2 Arms Transistor output SONIDO 100 mA 30 V DC short circuit protected 1010 16 KHZ Hz 0 2 Serial communication Fieldbuses Refresh rate PROFIBUS DP DeviceNet CANopen Modbus Ethernet AC input chokes AC output chokes Plug in type lt 10 ms between drive and fieldbus module 9 pin D connector Baud rate up to 12 Mbit s PROFIBUS DP and PROFIBUS DPV1 Network side based on PROF Idrive profile 5 pin screw type connector Baud rate up to 500 kbit s Network side based on ODVA AC DC drive profile 9 pin D connector Baud rate up to 1 Mbit s Network side based on CiA DS402 profile 4 pin screw type connector Baud rate up to 115 kbit s RJ 45 connector 10 Mbit s or 100 Mbit s Modbus TCP and EtherNet IP Network side based on ODVA AC DC drive profile EtherNet IP External option For reducin