Home

5 Inch Medium Speed Dome User Manual V2.0.0

image

Contents

1. lt TASK SETUP gt lt PATTERN SETUP gt BACK EXIT Figure 3 2 1 5 Inch Medium Speed Dome User Manual 3 2 1 SYSTEM PARAMETER SETUP The SYS PARAMETER SETUP menu is used for displaying the dome drive model software version available memory DIP switch information and other diagnostic information Refer to Figure 3 2 2 and Figure 3 2 3 e SOFT ADDR When the soft address is enabled the speed dome will use the soft address as shown in Figure3 2 2 with the addresses from 1 to 255 selectable When the SOFT ADDR option is set to OFF the hard address set by DIP switch is used if the address of the control device is 0 then the speed dome of any address can be controlled as well SYS PARAMETER SETUP SOFT ADDR NUM 0 SYS PARAMETER SETUP SOFT ADDR OFF lt PAN ZERO SETUP gt SOFT BAUD RATE 2400 lt DISPLAY SETUP gt SOFT BAUD OFF BROADCAST ADDRESS ON PELCO CHECKSUM ON lt TIME SETUP gt BACK EXIT en EN Figure 3 2 2 Figure 3 2 3 SOFT BAUD RATE When the SOFT BAUD option from the menu is set to ON the speed dome will use the soft baud rate as shown in Figure 3 2 2 with 2400 4800 9600 and 19200 selectable In this status it is invalid to set baud rate by DIP switch When the SOFT BAUD option is set to OFF the baud rate can be set by DIP switch Note When the soft baud rate function has been enabled and configured the dome will reboot to activate the settings and when the soft baud rate function is disabled the do
2. dome allows you to configure how labels are displayed on the monitor The following labels are available Zoom Identifies the amount of magnification Direction Displays compass direction with the format of NEXXX TXXX The XXX following NE refers to the degrees in northeast direction while the XXX following T indicates the degrees in vertical position The north direction can be set by menu E g NE235 T035 indicates the current position of the dome is in 235 degrees in northeast and 35 degrees in vertical position Time Support for time display 5 Inch Medium Speed Dome User Manual Chapter 3 Menu Operation Note The menu varies depending on camera models Menu Tree SYSPARAMETER SETUP SYS PARAMETER SETUP DISPLAY SETUP Y M D 07 01 18 SOFT ADDR NUM 0 lt PAN ZERO SETUP gt ZOOM DISPLAY SOFT ADDR OFF lt DISPLAY SETUP gt PT DISPLAY H M S 15 33 25 SOFT BAUD RATE 2400 TIME DISPLAY SOFT BAUD OFF PRESET DISPLAY DONE OPEN BROADCAST ADDRESS ON QUIT CLOSE PELCO CHECKSUM ON lt TIME SETUP gt BACK EXIT BACK EXIT BACK EXIT CAMERA SETUP CAMERA SETUP CAMERA SETUP FOCUS AF BLC WDR OFF WHITE BALANCE AUTO ZOOM LIMIT 18 BLC LEVEL NA RED 210 ZOOM SPEED HIGH AE MODE AUTO BLUE 150 SLOW SHUTTER ON IRIS 10 IMAGE FLIP OFF IRCUT FILTER AUTO SHUTTER 60 FOCUS LIMIT 30CM D N LEVEL N A GAIN 1 INIT LENS OFF SHAPNESS 9 EXPOSURE COMP 7 NOISE REDUCE N A BACK EXIT BACK EXIT BACK EXIT PTZ PARAMETER SETUP PTZ PARAMETER SETUP AUTO FLIP ON LIMITSTO
3. 5 Inch Medium Speed Dome User Manual V2 0 0 2010 01 5 Inch Medium Speed Dome User Manual Thank you for purchasing our product If there is any question or request please do not hesitate to contact dealer This manual is applicable to 5 Inch Medium Speed Dome This manual may contain several technically incorrect places or printing errors and the content is subject to change without notice The updates will be added into the new version of this manual We will readily improve or update the products or procedures described in the manual 5 Inch Medium Speed Dome User Manual Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss The precaution measure is divided into Warnings and Cautions Warnings Neglecting any of the warnings may cause serious injury or death Cautions Neglecting any of the cautions may cause injury or equipment damage Warnings Follow these safeguards to prevent serious Cautions Follow these precautions to injury or death prevent potential injury or material damage Warnings 1 In the use of the product you must be strict compliance with the electrical safety regulations of the nation and region 2 Please use the power adapter which is provided by normal company The standard of the power adapter is AC24V 3A 3 Do not connect several devices to one power adapter as adapter overload may cause over h
4. P OFF PROPORTIONAL PT ON lt LIMIT SETUP gt PARK TIME 5 lt CLEAR LIMIT gt PARK ACT NONE ELEVATION SET SCAN SPEED 30 IMAGE FREEZE OFF DOME PEED MID BACK EXIT BACK EXIT PRESET SETUP PRESET NUM lt UNDEFINED gt lt PRESET PTZ gt lt CLEAR PRESET gt MAIN MENUS DOME SETUP lt DOME SETUP gt lt SYS PARAMETER SETUP gt lt RESTORE DEFAULTS gt lt CAMERA SETUP gt lt RESTORE CAMERA gt lt PTZ PARAMETER SETUP gt BACK EXIT lt REBOOT DOME gt lt PRESET SETUP gt EXIT lt PATROL SETUP gt lt TASK SETUP gt lt PATTERN SETUP gt BACK EXIT PATROL SETUP NUM PRESET DWELL SPEED PATROL NUM 30 lt PATROL SETUP gt 30 lt PREVIEW PATROL gt 30 lt DELE PATROL gt 30 30 30 30 BACK EXIT DONE OPEN QUIT CLOSE IME ACTION STATE ONE OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF OFF TASK SETUP TASK NUM 1 TASK STATE OFF TASK ACTION NONE lt TASK TIME gt lt TASK PREVIEW gt lt TASK CLEAN gt WEEK WHOLE WEEK START lt H M gt 00 00 END lt H M gt 00 00 DONE OPEN QUIT CLOSE SS 255 308 o 9595 co 854 oococoocoococ So oococooocoo So BACK EXIT PATTERN SETUP PATTERN NUM REMAIN MEMORY 100 lt PATTERN SETUP gt DONE OPEN lt PREVIEW PATTERN gt QUIT CLOSE lt DELE PATTERN gt SPACE REMAIN BACK EXIT 5 Inch Medium Speed Dome User Manual 3 1 MAIN MENUS In PELCO P D or other PTZ protocols the main menu can be entered by calling preset 95 through DVR Keyboard or Client
5. SETUP gt DONE OPEN lt PREVIEW PATTERN gt QUIT CLOSE lt DELE PATTERN gt SPACE REMAIN BACK EXIT Figure 3 2 17 Figure 3 2 18 e PATTERN NUM The number of pattern under current operation The dome provides 4 patterns numbering from 1 to 4 PATTERN SETUP Enter the EDIT PATTERN menu as shown in Figure 3 2 18 Operate camera functions to configure the pattern The REMAIN 5 Inch Medium Speed Dome User Manual MEMORY indicates the memory available to configure the patterns When it displays 0 no patterns can be memorized any more Note When configuring and calling the pattern the auto flip will be valid and the pan tilt movement and the lens operation cannot be memorized simultaneously PREVIEW PATTERN Enter the PREVIEW menu to view the current pattern which has been defined O DELE PATTERN Enter the DELE PATTERN menu to delete the current pattern Note The deletion of the current pattern will cause its following pattern to be deleted as well e g if the pattern 2 is being deleted then pattern 3 and pattern 4 will be deleted as well 3 3 RESTORE DEFAULTS Use this function to reset all dome settings to factory default parameters including BET Exposure Comp Display of Zoom Display for 2 seconds Azimuth Elevation and Preset Label display 5 Inch Medium Speed Dome User Manual 3 4 RESTORE CAMERA Use this function to reset all camera settings to factory default parameters 3 5 REBOOT DOME Use this f
6. Software as shown in Figure 3 1 1 For instance press the PTZ button on DVR front panel to enter the PTZ control mode and then press the REC button followed by numeric 095 to access the main menu or press the SHOT numeric 095 and then the Enter button from the control keyboard to access the main menu In HIK Code protocol directly press the Menu button on DVR front panel to access the main menu Change cursor position through joystick or direction buttons on the front panel of DVR and move the cursor to the selected menu item Press IRIS to confirm 1 e operation can be done on this menu options If current menu contains sub menu enter the corresponding sub menu To perform operation on menu option the selected number behind menu item can be changed by moving joystick up and down Press IRIS to confirm and return to previous menu The same procedure is followed for the next operation for which no description is given Select Exit menu option to confirm and exit from menu operation MAIN MENUS lt DOME SETUP gt lt RESTORE DEFAULTS gt lt RESTORE CAMERA gt lt REBOOT DOME gt EXIT Figure 3 1 1 3 2 DOME SETUP Enter the DOME SETUP menu as shown in Figure 3 2 1 Note Use the Left and Right direction buttons to enter the next page and back to the previous page of the menu if available DOME SETUP lt SYS PARAMETER SETUP gt lt CAMERA SETUP gt lt PTZ PARAMETER SETUP gt lt PRESET SETUP gt lt PATROL SETUP gt
7. This feature enables the camera to perform daily lens initiation action to ensure the normal operation NOISE REDUCE The noise reduce function can be set to OFF HIGH MID and LOW The default setting is MID Note This feature varies depending on camera model 3 2 3 PTZ PARAMETER SETUP The PTZ PARAMETER SETUP menu is displayed in two pages as shown in Figure 3 2 9 and Figure 3 2 10 5 Inch Medium Speed Dome User Manual PTZ PARAMETER SETUP LIMITSTOP OFF lt LIMIT SETUP gt lt CLEAR LIMIT gt PTZ PARAMETER SETUP AUTO FLIP ON PROPORTIONALPT ON PARK TIME 5 PARK ACT NONE SCAN SPEED 30 IMAGE FREEZE OFF DOME PEED MID BACK EXIT ELEVATION SET BACK EXIT Figure 3 2 9 Figure 3 2 10 e ATUO FLIP The dome will rotate 180 degrees when the camera tilts downward and goes just beyond the vertical position When the dome rotates flips the camera starts moving upward as long as you continue to hold the joystick in the down position Once you let go of the joystick after the dome rotates joystick control returns to normal operation The auto flip feature is useful for following a person who passes directly beneath the dome This function can be realized by image center flip depending on different camera models PROPORTIONAL PT When the PROPORTIONAL PT is set to ON the dome will automatically reduce or increases the pan and tilt speeds in proportion to the amount of zoom At telephoto pan and tilt speeds will be slower for a given
8. WB This feature automatically processes the viewed image to retain color balance over a color temperature range The default setting for white balance is AUTO o Patrol The speed dome provides up to 4 patrols In each patrol user is allowed to specify the scanning track by a group of user defined presets with the scanning speed between two presets and the dwell time at the preset separately programmable o Pattern A pattern is a memorized repeating series of pan tilt zoom and preset functions that can be recalled with a command from a controller or automatically by a configured function park time task or power up By default the focus and iris are in auto status during the preset is being memorized o Power off Memory This feature allows the dome to resume its previous position or status after power is restored By default setting the dome supports the power off memory capability with the dwell time of 3 minutes Manchester Code Self test Enable the Manchester code diagnosis capability by setting the positions 4 5 and 6 of DIP Switch SW2 to ON During the use of the Manchester code diagnosis the corresponding fault code will be displayed on the screen not available during park time The detailed fault code is defined as below Cable is unconnected The cable is connected and data can be normally received but the address analysis is incorrect The cable is connected and data can be normally received but the comman
9. a limitation on the amount of telephoto zoom The settings vary depending on camera model Zoom amount optical zoomx digital zoom When the ZOOM LIMIT is set to the minimum value it indicates the digital zoom is disabled The default setting 1s in the maximum optical zoom e ZOOM SPEED Zoom speed allows the user to define the speed at which the dome will go from full wide zoom to the optical zoom with three levels selectable HIGH MID and LOW The default setting is HIGH e SLOW SHUTTER The shutter will automatically slow down to obtain clearer figure through exposure time extension under low lightening The default setting is ON eo IRCUT FILTER The IR cut filter can be set to AUTO DAY and NIGHT In auto mode the camera is capable of automatically switching Black amp White mode NIGHT and Color mode DAY with regard to environment lightening conditions In manual switch mode user can increase sensitivity in low light conditions by switching to Black amp White mode while the Color mode is preferred in normal lighting conditions The default setting is AUTO The DAY mode can be set by calling preset 39 and the NIGHT mode set by preset 40 o D N LEVEL The D N level is the light level at which the IR cut filter switches DAY or NIGHT Three levels are selectable HIGH MID and LOW The default setting is MID Note This feature varies depending on camera model SHARPNESS The sharpness function enhances picture detail by increasing the apertur
10. amount of joystick deflection than at wide zoom settings This keeps the image fast on the monitor when there is a large amount of zoom When the PROPORTIONAL PT is set to OFF it will be difficult to trace the object at low pan and tilt speeds or no movement in large amount of zoom Note This feature is enabled all the time while setting the patterns PARK TIME This feature allows the dome to begin a specified operation scan preset or pattern after a configured period of inactivity Park time can be configured from 5 to 720 seconds Note If no control signal is received for a period of time during the dome actions by calling special presets then no automatic actions will be performed PARK ACT This feature will define the activity when the dome parks The selectable park actions include presets1 8 patterns1 4 patrols1 4 pan scan tilt scan random scan frame scan panoramic scan or none SCAN SPEED Scan speed is the degrees per second of the pan scan tilt scan frame scan random scan and panoramic scan Scan speed is adjustable from to 40 degrees per second through the camera menu IMAGE FREEZE This feature freezes the scene on the monitor when going to a preset This allows for smooth transition from one preset scene to another Preset freeze frame also reduces bandwidth when used with digital network systems and guarantees that blanked areas will not be revealed when going to a preset Oo DOME SPEED The manual dome m
11. an oo am on a an 5 Inch Medium Speed Dome User Manual Appendix 4 Table of Wire Gauge Standards Bare g gt e American Wire Gaae Cross sectional Area g British Standard Wire Gauge ofBare Wire a Qu a gt Mo BO ho M Oo 03 05 Go 05 E B BR gt m on MP Go 100 M co M uj O 19 SWG
12. d E3 analysis is incorrect The cable is connected and data can be normally received but the analysis of address and command is incorrect The cable is connected but the received data does not comply with the requirements of Manchester code o Time Task A time task is a preconfigured action that can be performed automatically at a specific date and time The programmable actions include preset 1 8 pattern 1 4 patrol 1 4 pan scan tilt scan random scan frame scan panorama scan day night mode or none Compass Direction The dome will show the direction when user manually controls it to rotate The detailed display information is as below The azimuth zero indicates the north direction Oo RS 485 Failure Diagnostics In the presence of failure at the transmitting and receiving terminals of RS 485 communications the speed dome is capable of performing self test and detecting the fault results which will be displayed on the screen o Soft Baud Rate The baud rate of dome can be configured by the menu without need of DIP switch settings 5 Inch Medium Speed Dome User Manual Chapter 2 Operation Instructions 2 1 Power up Action After the power is applied the speed dome will perform self test action that begins with lens actions and then pan and tilt movement After completion of power up self test actions the interface as shown in Figure 2 1 will be displayed on screen for 120 seconds The System Information disp
13. e dome cover avoid direct contact with the dome cover because the acidic sweat of the fingers may erode the surface coating of the dome cover 7 Please use a soft and dry cloth when clean inside and outside surfaces of the dome cover not to use alkaline detergents 5 Inch Medium Speed Dome User Manual Table of Contents TADO EE OPM CIS nennen AA EA AE AAA 3 Chapter LBS A db 4 IAN A lee A T AT A 4 A a ee a a 4 13 o AA PP O O A 4 Chapter 2 OP oa II oO ee ee een en A rreake 7 Z NI Oe LO O o o A ee 1 DED TS ASIC Oe aU COINS een 7 2 3 Presets with Specia PUNCHONS ua u es occ 8 2A NAS LIS IV ss cas ie ida E 8 Mc ry ES A A tne tenc EA EA 9 3b MAIN MENOS isses irren 10 32 DOME SETUP isn tn essentielle dd sides 10 3 2 1 SYSTEN PARAMETER SETUP ista int E 11 SSA AMERA SE AAA A RO O ee 12 SL PTA PARAMETER SPA UA o oi 14 32A PRESETS ares otc eae tee ces A A AAA A A AA 16 323 PATROLS E TOUP dida 16 FCA PTOUR 2 ee e ee II A 17 32 C PATTERN SETUP ii id 18 30 RESTORE DEFAULT ES sa sun ae ante as 19 FARES TOR ECAMT A ee EE ee er 20 SE BOE DOME ve ee euer ti 20 Appendix Lihn Sure Protection le 21 Appendix 2 RS485 Bus Connection au u u u u eal ed deed eee a ea 22 Appendix 3 24VAC Wire Gauge amp Transmission Distance oooooooooooooooooooooonononnnonononnnnnonnnnnnnnono nono nono non nono nn nn ono nnnnnnnnos 25 Appendix 4 Table Of Wire Gauss Bands ici ido eiii 26 5 Inch Medium Speed Dome User Manual Chapter 1 Brief Introduc
14. e gain of the camera and sharpening the edges in the picture Levels from 1 to 16 are selectable with the default setting of level 9 o BLC WDR If a bright backlight is present the subjects in the picture may appear dark or as a silhouette Backlight compensation BLC enhances objects in the center of the picture The dome uses the center of the picture to adjust the iris If there is a bright light source outside of this area it will wash out to white The camera will adjust the iris so that the object in the sensitive area is properly exposed 5 Inch Medium Speed Dome User Manual When the Wide Dynamic Range WDR function is on the dome is able to balance the brightest and darkest sections of a scene to produce a picture that is better balanced in lighting and provides more details Note The BLC WDR feature varies depending on camera model The default setting is for BLC function o BLC LEVEL This feature is used for adjusting the backlight compensation level Note The feature varies depending on camera model o AE MODE The AE mode can be set to AUTO IRIS SHUTTER GAIN or MANUAL When it is set to AUTO the auto iris auto shutter and auto gain functions are all enabled when it is set to IRIS the iris function adopts the defined value while the auto shutter and auto gain remain to be enabled when it is set to SHUTTER the shutter function adopts the defined value while the auto iris and auto gain remain to be enabled and when it is
15. eat or fire hazard 4 Please make sure that the plug is firmly connected on the power socket 5 When the product is installed on wall or ceiling the device shall be firmly fixed 6 If smoke odors or noise rise from the device turn off the power at once and unplug the power cable and then please contact the service center 7 If the product does not work properly please contact your dealer or the nearest service center Never attempt to disassemble the camera yourself We shall not assume any responsibility for problems caused by unauthorized repair or maintenance Warnings 1 Do not drop the dome or subject it to physical shock and do not expose it to high electromagnetism radiation Avoid the equipment installation on vibrations surface or places subject to shock ignorance can cause equipment damage 2 Do not place the dome in extremely hot cold the operating temperature shall be 30 C 65 C dusty or damp locations or fire or electrical shock will occur otherwise 3 The dome cover for indoor use shall be kept from rain and moisture 4 Exposing the equipment to direct sun light low ventilation or heat source such as heater or radiator is forbidden ignorance can cause fire danger 5 Do not aim the camera at the sun or extra bright places A blooming or smear may occur otherwise which is not a malfunction however and affecting the endurance of CCD at the same time 6 Please use the provided glove when open up th
16. enu The dome provides OSD menu for setting of dome parameters o Self adaptive to Multiple Protocols The dome is compatible with PELCO D PELCO P and HIK Code protocol etc and 1s capable of being self adaptive to these protocols without need of selecting protocol by DIP switch settings Oo Keyboard Control The pan tilt movement and zoom actions of dome can be controlled by the control keyboard DVR matrix etc 5 Inch Medium Speed Dome User Manual eo Limit Stops The dome can be programmed to move within the limit stops left right up down which are configurable by the control keyboard DVR or client application software Oo Auto Scan The dome provides 5 scanning modes pan scanning tilt scanning frame scanning random scanning and panorama scanning The scanning speed can be set by OSD menu from level 1 to 40 with the corresponding speed ranging from 1 second to 40 second Preset Freeze Frame This feature freezes the scene on the monitor when going to a preset This allows for smooth transition from one preset scene to another and also guarantees that masked area will not be revealed when going to a preset Presets Each of the user definable presets can be programmed to use pan tilt camera settings and other settings When preset is called the dome will automatically move to the defined position User is allowed to add modify delete and call each preset Label Display The on screen label of the preset title azim
17. layed on the screen includes the Dome Address Protocol Version and other information The COM FORM refers to the baud rate data bit and stop bit of the dome e g 2400 8 1 indicates the dome is configured with the baud rate of 2400 8 data bits and 1 stop bit DS 2AM1 501 D280000162 2 COM FORMAT 2400 8 1 PROTOCAL SELF ADAPTIVE VERSION 2 10 BUILD DATE 09 11 17 Figure 2 1 2 2 Basic Operations The following operation shall be done with the use of control device or client software The control devices include control keyboard and DVR etc And the client refers to the client application software Examples are given here for common operation provided that the current control system supports following operation Please refer to Client Software User Manual for detail operation guide Pan and tilt movement move the joystick to the desired direction or press the Up Down Left Right buttons Zoom operation press ZOOM TELE button to make the lens closer and magnify the scene Press ZOOM WIDE button to make the lens farther and minify the scene Focus operation After FOCUS FAR button is pressed the object far away will become clearer while the object in vicinity will be ambiguous After FOCUS NEAR button is pressed the object in vicinity will become clearer while the object far away will become ambiguous In auto focus mode camera will focus automatically to maintain clear image This feature can also be achieved by manua
18. lly as well However after other operation of device camera will resume auto focus Iris operation press IRIS OPEN to enlarge the iris and increase the image brightness And by pressing IRIS CLOSE the iris will gradually shrink that decreases image brightness In auto iris mode the IRIS OPEN and IRIS CLOSE buttons are still operable However after finishing other operation by dome camera will resume auto iris action Preset operation Preset can be programmed or called through keyboard or menu The dome provides 256 presets Press the SHOT button and then the 5 Inch Medium Speed Dome User Manual numeric keys to call the programmed preset E g the callup of preset 08 can be achieved by pressing PRESET button and then the numeral 08 Please refer to Section 3 2 4 for the configuration of presets Note The callup of presets including the presets with special functions will be restricted by the limit stops if defined Callup of presets programmed out of the limit stops will be invalid 2 3 Presets with Special Functions The following presets are predefined with special functions gt w S s soes SSS O ra f p rara Sing a Fsmmansaming NINE CT A O o eee O Note In Manchester code control the presets predefined with special functions are shown as below 65 Remote reboot 67 Auto flip es resmin s es son mg 71 sannmem GENE gt a Program pattern2 Program pattern3 2 4 Label Display The
19. me will reboot as well eo BROADCAST ADDRESS When the BROADCAST ADDRESS is set to ON the control device with address 0 is capable of controlling all domes connected to it eo PELCO CHECKSUM When the dome in PELCO P and PELCO D protocol cannot be controlled user may enable this function to solve the problem e TIME SETUP The TIME SETUP allows user to set the date and time of the dome As shown in Figure 3 2 4 the message indicates the current date and time is 15 33 25 on January 18 2007 Move the joystick of the keyboard or use the Left and Right buttons on DVR front panel to select the option and move the joystick of the keyboard or use the Up and Down buttons to modify the value Y M D 07 01 18 H M S 15 33 25 DONE OPEN QUIT CLOSE Figure 3 2 4 5 Inch Medium Speed Dome User Manual e PAN ZERO SETUP North Direction Enter the PAN ZERO SETUP menu and then use the joystick of keyboard or the direction buttons on DVR front panel to define the amount of pan from zero degrees vertical and finally press the ris button to save settings and exit the current menu e DISPLAY SETUP The DISPLAY SETUP menu is displayed in Figure 3 2 5 Each item can be set with the separate display time on screen from 2sec 5sec and 10 sec selectable or set to be ON or OFF The preset display position can overlapped the display positions of azimuth elevation and zoom If both of the ZOOM DISPLAY and the PT DISPLAY are set to ON then in the preset ope
20. ndividual the resistance should be no more than 4Q the section al area of the grounding cable should be no less than 25mm For grounding instructions please refer to the Installation Manual of Speed Dome video arrester 2 E lightning rod communicate arrester porer arrester The speed dome should be in the range of 45 degrees under the lightning rod the resistance of earthing conductor should be smaller than 41 steel jacket 5 Inch Medium Speed Dome User Manual Appendix 2 RS485 Bus Connection 1 General Property of RS485 Bus According to RS485 industry bus standard RS485 is a half duplex communication bus which has 1200 characteristic impendence the maximum load ability 1s 32 payloads including controller device and controlled device 2 RS485 Bus Transmission Distance When using 0 56mm 24AWG twisted pair line according to different baud rate the max transmission distance theory table is shown as below 2400BPS 4800BPS 1200m The transmission distance will be decreased if we use the thinner cable or use this product under the strong electromagnetic interference situation or there are lots of devices are added to the bus on the contrary the transmission distance will be increased 3 Connection Method and Terminal Resistance 1 RS485 industry bus standard require daisy chain connection method between any devices both sides have to connect a 120Q terminal re
21. o be edited move the joystick up and down or Up and Down direction buttons to set values Follow the same steps to edit the other presets Use the joystick or the Right direction button to enter the next page The preset edited in the patrol can be modified or deleted as well In default setting the preset number is initialized as 0 dwell time is 6 seconds 0 30 seconds selectable and the patrol speed is level 30 level 1 40 selectable Press IRIS to save the current settings or press IRIS to cancel settings and return to the previous menu Note Different from the preset speed mentioned in section 3 2 3 the patrol speed above refers to level 1 x 1 4 with the unit of degree per second eo PREVIEW PATROL Enter the PREVIEW menu to view the current patrol if defined which enables the dome to scan among the presets as predefined O DELE PATROL Enter the DELE PATH menu to delete the current patrol 3 2 6 TASK SETUP A task is a preconfigured camera action that can be performed automatically at a specific date and time The TIME TASK settings menu is shown in Figure 3 2 14 TASK SETUP TASK NUM l TASK STATE OFF TASK ACTION NONE lt TASK TIME gt lt TASK PREVIEW gt lt TASK CLEAN gt BACK EXIT Figure 3 2 14 eo TASK NUM The number of task to be configured Move the joystick up and down or Up and Down direction buttons to select from number to8 o TASK STATE 5 Inch Medium Speed Dome User Manual Set the task f
22. ovement speed can be set to HIGH MID or LOW LIMITSTOP Limit stops are configurable stops that limit the pan and tilt range of the dome There may be left right and up down limit stops configurable to define an area When the LIMIT STOP function is set to OFF the movement of dome will not be limited despite of 5 Inch Medium Speed Dome User Manual defined limit stops eo LIMIT SETUP To set limit stops manually 1 Enter the SETTING STOPS menu 2 Follow the directions SET LEFT LIMIT displayed on the monitor and use the joystick or the direction buttons on DVR front panel to the desired location of left limit stop 3 Press the IRIS button to finish the setting of left limit stop 4 Follow the same steps to set the right up and down limit stops in sequence according to the directions displayed on the monitor The new settings of limit stops will overwrite the existed settings o CLEAR LIMIT The defined limit stops can be cleared by this menu ELEVATION SET To set elevation on tilt direction to set ON is 5 to 185 to set OFF is 0 to 180 the unit is degree 3 2 4 PRESETS The PRESETS menu is displayed as shown in Figure 3 2 11 PRESET SETUP PRESET NUM lt UNDEFINED gt lt PRESET PTZ gt lt CLEAR PRESET gt BACK EXIT Figure 3 2 11 PREST NUM The dome provides 256 presets The PRESET NUM displays the preset under current operation If the preset has been defined the corresponding number will appear while no preset i
23. ration status the preset label will be displayed all the time while in other operation status the azimuth elevation and zoom label are displayed all the time DISPLAY SETUP ZOOM DISPLAY PT DISPLAY TIME DISPLAY PRESET DISPLAY BACK EXIT Figure 3 2 5 3 2 2 CAMERA SETUP Note Different dome models are programmed with different Camera Settings menu The CAMERA menu is displayed in three pages as shown in Figure 3 2 6 Figure 3 2 7 and Figure 3 2 8 CAMERA SETUP CAMERA SETUP FOCUS AF BLC WDR OFF ZOOM LIMIT 18 BLC LEVEL N A ZOOM SPEED HIGH AE MODE AUTO SLOW SHUTTER ON IRIS 10 IRCUT FILTER AUTO SHUTTER 60 D N LEVEL N A GAIN 1 SHAPNESS 9 EXPOSURE COMP 7 BACK EXIT BACK EXIT Figure 3 2 6 Figure 3 2 7 5 Inch Medium Speed Dome User Manual CAMERA SETUP WHITE BALANCE AUTO RED 210 BLUE 150 IMAGE FLIP OFF FOCUS LIMIT 30CM INIT LENS OFF NOISE REDUCE N A BACK EXIT Figure 3 2 8 eo FOCUS The camera provides three focus modes for selection AF auto HAF half auto and MF manual In auto focus mode the camera will allow the lens to remain in focus when using pan tilt and zoom PTZ functions In manual focus mode the focus can be operated manually In half auto focus mode the camera will remain in a fixed focus position when all PTZ motions are stopped And when the PTZ motions are resumed the camera will focus automatically The default setting is AF e ZOOM LIMIT Zoom limit allows the user to define
24. s defined it will display UNDEFINED The presets which are predefined for specific functions will not be displayed and no change is allowable Please refer to page 9 for presets with specific functions PRESET PTZ Enter the PRESET PTZ menu to edit preset scene Use the joystick or direction buttons to move PTZ to the desired scene and then press the IRIS to confirm the settings and return to the previous menu or press IRIS to cancel settings Note The setting of preset scene will be restricted by the limit stops if defined CLEAR PRESET This feature is used for clearing the current preset 3 2 5 PATROL SETUP The PATROL settings menu is shown in Figure 3 2 12 PATROLS NUM The number of patrol under current operation The dome provides 4 patrols numbering from 1 to 4 5 Inch Medium Speed Dome User Manual PATROL SETUP NUM PRESET DWELL SPEED PATROL NUM 30 lt PATROL SETUP gt 30 lt PREVIEW PATROL gt 30 30 30 30 4 2 3 lt DELE PATROL gt 4 30 5 6 7 BACK EXIT DONE OPEN QUIT CLOSE Figure 3 2 12 Figure 3 2 13 PATROL SETUP The EDIT PATROL settings menu is shown in Figure 3 2 13 A patrol can be configured with 32 presets To edit a patrol l 2 3 4 5 Move the joystick up and down or Up and Down direction buttons to select the preset to be edited Move the joystick left and right or Left and Right direction buttons to select among PRESET DWELL TIME and SPEED After having selected the item t
25. set to GAIN or MANUAL the gain value can be adjusted or the iris gain and shutter values are all adjustable The default setting is AUTO Note The Gain or Manual feature varies depending on camera model IRIS The iris is the lens function that opens and closes the iris in response to changing light conditions with the numeric values from 0 to 17 selectable SHUTTER The Shutter is the duration of the electronic shutter User can set the shutter speed to 1 2 4 8 15 30 60 125 180 250 500 1000 2000 4000 or 10000 The numeric value of X indicates the shutter speed 1s 1 X second o GAIN The Gain indicates the amplification degree of the original image signal with the numeric values from 0 to 15 selectable e EXPOSURE COMP The exposure compensation effect can be adjusted through exposure volume adjustment The numeric values from 0 to 14 are selectable with the default setting of 7 eo WHITE BALANCE This feature automatically processes the viewed image to retain color balance over a color temperature range The dome provides 5 modes for selection AUTO INDOOR OUTDOOR SELFDEF self defined and ATW When the SELFDEF is selected set the value of RED and BLUE O IMAGE FLIP This feature allows the video image to be mirrored on the screen eo FOCUS LIMIT The focus limit can be set to ICM 30CM 1M or 3M The feature allows the camera to perform auto focus out of the focus limit The default setting 1s 1M e INIT LENS
26. sistance show as Diagram 1 the simplified connection method is shown as diagram 2 but the distance of D should not be too long 1 2 3 AH 32H Diagram 2 2 Connection of 120Q terminal resistor The 120Q terminal resistor can be connected through the DIP switch on the communications board as shown in Figure3 For a new dome the 120Q matching resistor is defaulted as unconnected switch on the eighth bit of SW2 it will be connected Conversely switch off the eighth bit of SW2 it will be unconnected 5 Inch Medium Speed Dome User Manual LER EEE EM EM DER EBE EG SW1 i 2 3 4 7 7 3 SW 2 1 i en Sn 6 7 E DIP ON DIP ON t Figure 3 4 Problems in the Practical Application Normally users adopt star shape connection method in construction under this situation the terminal resistors must be connected between two farthest devices as Figure 4 1 and 15 but this connection method is not satisfy the requirement of the RS485 industry standard so that it will lead to some problems such as signal reflection anti jamming ability decline when the devices are faraway At this time the dome will be uncontrollable or self running etc Figure 4 For such case the best way is adding a RS485 distributor This product can effectively change the star shape connection to which satisfies the requirement of RS485 industry standard in order to avoid those problems and improve the communication reliability Sho
27. tion 1 1 Description Adopting the high performance integral dome drive with auto iris auto white balance and other capabilities the medium speed dome is integrated with the built in pan tilt unit and the digital receiver The dome provides Manchester code and wiring failure diagnosis with precise drive it features high reaction sensitivity and reliable running ensuring superior image stability it also provides 3D intelligent positioning capability during the use of client application software The medium speed dome has become a high tech security product in the surveillance field depending on its outstanding performance and full integral functions The dome is designed with power capabilities including preset and pan patrol tilt frame random panorama pattern scanning it also features manual limit stops auto flip backlight compensation etc The dome supports PELCO D PELCO P and HIK Code protocols being self adaptive to different protocols For ease of operation the dome address can be assigned either by DIP switch settings or software OSD menu allows user to program dome settings preset settings pattern settings etc The medium speed dome can be widely applied to various monitoring scenes such as the river forest road railway airport harbor oil field sentry plaza park scenic spot street station stadium etc 1 2 Outline Back Box Dome Drive Bubble 5 Inch Medium Speed Dome 1 3 Functions o OSD M
28. to Focus The auto focus enables the camera to focus automatically to maintain clear video images O IR Cut Filter The IR cut filter can be set to Auto Day and Night In auto mode the camera is capable of automatically switching Black amp White mode Night and Color mode Day with regard to environment lightening conditions In manual switch mode user can increase sensitivity in low light conditions by switching to Black amp White mode while the Color mode is preferred in normal lighting conditions o Low Light Electronic Shutter The shutter speed will automatically slow down in low illumination conditions to maintain clear video images by extending the exposure time The feature can be enabled disabled by the menu Backlight Compensation BLC If a bright backlight is present the subjects in the picture may appear dark or as a silhouette Backlight compensation BLC enhances objects in the center of the picture The dome uses the center of the picture to adjust the iris If there is a bright light source outside of this area it will wash out to white The camera will adjust the iris so that the object in the sensitive area is properly exposed eo Wide Dynamic Range WDR 5 Inch Medium Speed Dome User Manual When the Wide Dynamic Range WDR function is on the dome is able to balance the brightest and darkest sections of a scene to produce a picture that is better balanced in lighting and provides more details o White Balance
29. unction to be ON or OFF o TASK ACTION This feature defines the activity the dome will perform at the specific time The selectable actions include presets1 8 patterns 1 4 patrols 1 4 pan scan tilt scan random scan frame scan panoramic scan day mode night mode or none o TASK TIME Refer to Figure 3 2 15 for time task settings TIME ACTION STATE NONE OFF NONE OFF NONE OFF NONE OFF NONE OFF NONE OFF NONE OFF NONE OFF WEEK WHOLE WEEK START lt H M gt 00 00 END lt H M gt 00 00 DONE OPEN QUIT CLOSE oO SO PR DN m gt O rar er SO ii SS CS gt O o Ca SS OS OD gt O DO SS O Figure 3 2 15 Figure 3 2 16 Use the joystick or Left and Right buttons to position the cursor beside WEEK START H M or END H M and then use the joystick or Up and Down buttons to select the specific day or time The weekday can be set to be from Monday to Sunday or Whole Week o TASK PREVIEW Enter the TASK PREVIEW menu to view the time action and state of the current task defined Refer to Figure 3 2 16 o TASK CLEAN Enter the TASK CLEAN menu to delete the time and action of the current task 3 2 7 PATTERN SETUP A pattern is a memorized repeating series of pan tilt zoom and preset functions that can be recalled with a command from a controller or automatically by a configured function park time task or power up Refer to Figure 3 2 17 for the PATTERNS settings menu PATTERN SETUP PATTERN NUM REMAIN MEMORY lt PATTERN
30. unction to reboot the system 5 Inch Medium Speed Dome User Manual Appendix 1 Lightning amp Surge Protection This product adopts TVS plate lightning protection technology to avoid damage caused by pulse signal that is below 3000W like instantaneous lighting surging etc According to the actual situation outdoors necessary protection measures must be taken to secure the electrical safety 1 The distance between signal transmission line and High voltage equipment or high voltage cable is at least 50m 2 Outdoor wiring should better be along the eaves as much as possible 3 In the open field wiring should be buried underground in sealed steel pipe and the steel pipe should be one point grounding Overhead routing method is forbidden 4 In strong thunderstorm area or high induction voltage areas such as high voltage transformer substation high power lightning protection apparatus and lightning conductor are necessary to be appended 5 The design for installation and wiring with lightning protection and grounding in mind should be combined with the lightning protection consideration of the building and conform to the related national standards and industry standards 6 The system should be equipotentially grounded and the grounding equipment must satisfy double request of system anti jamming and electric safety and it must not appear short circuit and open circuit with the zero conductor of strong grid When the system is grounding i
31. uth elevation zoom and other operations can be programmed by menu and displayed on the monitor O Auto Flip In manual tracking mode when a target object goes directly beneath the dome the dome will automatically rotate 180 degrees in horizontal direction to maintain continuity of tracking When the dome rotates flips the camera starts moving upward as long as you continue to hold the joystick in the down position This function can be realized by image center flip depending on different camera models The feature can be enabled disabled through the menu eo 3D Intelligent Positioning The speed dome can be controlled with the 2 buttons and scroll of mouse can be used under HIK Code protocols with devices and client software Click on a certain area and the device will move to the scene with corresponding point as the center When a rectangular area is selected by left clicking the mouse device will move to its center and enlarge it With right clicking the lens will zoom in and the scroll can easily make the lens zooming and mouse operation automatically incorporates zooming effect o Proportional Pan Proportional pan automatically reduces or increases the pan and tilt speeds in proportion to the amount of zoom At telephoto zoom settings the pan and tilt speeds will be slower for a given amount of joystick deflection than at wide zoom settings This keeps the image from moving too fast on the monitor when there is a large amount of zoom O Au
32. w as figure 5 5 Inch Medium Speed Dome User Manual RS485 Distributor Figure 5 1 FAQ of RS485 Bus Fault Phenomenon Probable Cause The speed 1 The address or Baud Rate is not matched dome do the between Host and the Speed Dome self check but 2 R5485 are connected incorrectly can not be 3 Wiring drops controlled 4 R5485 wire broke The speed 1 loose contact of K5485 dome can be 2 one R5485 wire broke controlled but 3 Host and speed dome are too far awaye not smoothly 4 Too many speed domes are connected Solutions 1 Adjust the address or Baud Rate of Host or Speed Dome to make a match 2 Change the R5485 and R5485 wires 3 fastening the wirer 4 Change R5485 wires 1 fastening R5485 wire 2 Change R5485 wires 3 Add terminal matched resistances 4 Add R5485 distributore 5 Inch Medium Speed Dome User Manual Appendix 3 24VAC Wire Gauge amp Transmission Distance The following table has described the recommended max distance adopted for the certain wire gauge when the 24VAC voltage loss rate is less than 10 For the AC driven device the maximum voltage loss rate allowable is 10 For example for a device with the rating power of 80VA which is installed at a distance of 35 feet 10m away from the transformer then the minimum wire gauge required is 0 8000mm Distance ___feet m Power vay 0 8000 1 000 250 Pres 000 e 451 137 716 218 Ca