Home
MAXMIN User Manual
Contents
1. To define the prefix name for the backing files created in this run Optional FILES fname Parameters FILES keyword fname prefix name for any backing files created by this run Alphanumeric 4 characters first character must be alphabetic Note fname is used as a prefix for all files created during the current run The four characters are appended with two digits in the range 12 to 35 to create each individual file Example FILES BILL A 6 TITLE Command To define a title for this run Recommended Contains proprietary and confidential information of ANSYS Inc and its subsidiaries and affiliates Page A 4 MAXMIN User Manual Preliminary Data Deck for MAXMIN TITLE title Parameters TITLE keyword title this line of text will be printed out at the top of each page of ASAS output Alphanumeric up to 74 characters Example TITLE THIS IS AN EXAMPLE OF A TITLE LINE A 7 TEXT Command To define a line of text to be printed once only at the beginning of the output Several TEXT lines may be defined to give a fuller description of the current analysis on the printed output TEXT text Parameters TEXT keyword text this line of text will be printed once at the beginning of the output Alphanumeric up to 75 characters Example EX THIS EXAMPLE OF THE TEXT EX COMMAND IS SPREAD EX OVER THREE LINES A 8 S
2. The data for MAXMIN is entered in up to 4 distinct blocks as shown below Of these only the LOAD and STOP commands are compulsory Contains proprietary and confidential information of ANSYS Inc and its subsidiaries and affiliates Data Formats Page 2 2 MAXMIN User Manual 2 4 LOADCASE Selection Commands STRUCTURE sname MAXMIN sname COMPONENT sname tree LOAD END case ar ema ELEMENT END elno a Caen GROUP __ END A Es Poo groups eA OUTPUT END Icno ea STOP Data Formats Each LOAD command contains a list of loadcase numbers The final LOAD command must carry the word END between the word LOAD and the first loadcase number 4 STRUCTURE sname MAXMIN _ Shame HW COMPONENT sname tree LOAD END C case 5 Parameters Contains proprietary and confidential information of ANSYS Inc and its subsidiaries and affiliates Page 2 3 MAXMIN User Manual Data Formats STRUCTURE keyword to denote that loadcases from a different structure are to be utilised For a substructured analysis this command may be followed by a COMPONENT command MAXMIN keyword to denote that loadcases from a previous MAXMIN run are to be utilised For a substructured analysis this command may be followed by a COMPONENT command COMPONENT k
3. and its subsidiaries and affiliates Page A 7 MAXMIN User Manual Preliminary Data Deck for MAXMIN NEWSTRUCTURE STR2 A 11 OPTIONS Command To define the control options for this run Optional OPTIONS g option ee Parameters OPTIONS keyword option 4 character option name or list of option names Valid options are DATA Performs data checking only NOBLDo not print the MAXMIN title pages PRNO Suppress printing of the input data BOTH Reguests that for all axial elements i e FLA2 FLA3 GRIL BM2D BM3D BEAM CURB GCB3 FAX3 TCBM TUBE and BAX3 the maximum and minimum values are to be computed for each end of the element Note that if this option is set then any subseguent MAXMIN run to access this run must also include the BOTH option Similarly if the initial MAXMIN run did not include a BOTH option no subseguent MAXMIN run may include it Example OPTIONS DATA END A 12 SAVE Command To specify that results of this MAXMIN run are to be saved in a file for further enveloping in subseguent MAXMIN runs SAVE LOCO FILES Parameters Contains proprietary and confidential information of ANSYS Inc and its subsidiaries and affiliates Page A 8 MAXMIN User Manual Preliminary Data Deck for MAXMIN SAVE keyword LOCO keyword to indicate files to be saved for further MAXMIN processing FILES Keyword Note The use of LOCO does not imply that the files created by this run may be
4. ATA AREA 350000 PROJECT BHAA JOB POST FILES BHST TITLE EXAMPLE OF COMPONENTS IN MAXMIN STRUCTURE STRU NEWSTRUCTURE STNW OMPONEN STRU BLVW RHS2 OMPONENT STSL BRNP RHLS vs C a C A f n ly 9 G S2 BRNP RHLS O ga O Z E U N n n G S C L S COMPONENT STRU BLVW R L S cC L S J o rJ Contains proprietary and confidential information of ANSYS Inc and its subsidiaries and affiliates Page 3 4 MAXMIN User Manual Preliminary Data Deck for MAXMIN Appendix A Preliminary Data Deck for MAXMIN A l Introduction The preliminary data is the first block of the MAXMIN information It defines the size of the job and the structure component that will be processed during the course of the analysis SYSTEM DATA AREA memory PROJECT pname JOB _ POST FILES fname _ TITLE title TEXT text STRUCTURE sname COMPONENT sname tree NEWS TRUCTURE nsname OPTIONS option 5 SAVE LOCO FILES END The preliminary data must commence with the SYSTEM command and terminate with END Within these bounds the other commands may be given in any order It is suggested however that the order given above is adopted AD SYSTEM Command To defi
5. MAXMIN Run This run combines the information from the original analysis Project and File Names GD12 with the previous MAXMIN run File Name YZLO Contains proprietary and confidential information of ANSYS Inc and its subsidiaries and affiliates Page 3 2 MAXMIN User Manual Examples SYSTEM DATA AREA 320000 PROJECT GD12 JOB POST FILES ZZLl TITLE SUBSEQUENT USAGE OF MAXMIN ON GD12 YZLO STRUCTURE GD12 NEWSTRUCTURE ZZLl OPTIONS END END LOAD MAXMIN YZLO LOAD END 1 STOP 3 4 Example 4 Substructured Usage of MAXMIN This example demonstrates the use of MAXMIN with the substructure facility The tree structure is as follows Project Name BHAA Structure STRU Structure STSL Assembled component Assembled component name BLVW name BRNP Assembled component Assembled component name RHS2 name RHLS The stress values are drawn from component RHS2 of structure STRU and component RHLS of structure STSL Components RHS2 and RHLS are both usages of the same master component and of course all the structures and components have been run under the same project name BHAA Components BLVW and BRNP are intermediate components between the ones used and their structures New files created will be identified by BHST Contains proprietary and confidential information of ANSYS Inc and its subsidiaries and affiliates Page 3 3 MAXMIN User Manual Examples SYSTEM D
6. MAXMIN User Manual Version 12 ANSYS Inc Southpointe 275 Technology Drive Canonsburg PA 15317 ansysinfo ansys com http www ansys com T 724 746 3304 F 724 514 9494 Copyright 2009 Century Dynamics Limited All Rights Reserved Century Dynamics is a subsidiary of ANSYS Inc Unauthorised use distribution or duplication is prohibited ANSYS Inc is certified to ISO 9001 2008 Revision Information The information in this guide applies to all ANSYS Inc products released on or after this date until superseded by a newer version of this guide This guide replaces individual product installation guides from previous releases Copyright and Trademark Information 2009 SAS IP Inc All rights reserved Unauthorized use distribution or duplication is prohibited ANSYS ANSYS Workbench AUTODYN CFX FLUENT and any and all ANSYS Inc brand product service and feature names logos and slogans are registered trademarks or trademarks of ANSYS Inc or its subsidiaries located in the United States or other countries CEM CFD is a trademark used by ANSYS Inc under license All other brand product service and feature names or trademarks are the property of their respective owners Disclaimer Notice THIS ANSYS SOFTWARE PRODUCT AND PROGRAM DOCUMENTATION INCLUDE TRADE SECRETS AND ARE CONFIDENTIAL AND PROPRIETARY PRODUCTS OF ANSYS INC ITS SUBSIDIARIES OR LICENSORS The software products and documentation are f
7. TRUCTURE Command To define the name of an existing structure within the current project that is to be processed in this run Contains proprietary and confidential information of ANSYS Inc and its subsidiaries and affiliates Page A 5 MAXMIN User Manual Preliminary Data Deck for MAXMIN STRUCTURE sname Parameters STRUCTURE keyword sname structure name identifying which existing structure is to be accessed from the project defined on the PROJECT command Alphanumeric 4 characters the first character must be alphabetic Note The loadcase information to be processed may be drawn from more than one structure and this is achieved by respecifying a STRUCTURE command within the MAXMIN data see Section 2 3 The structure defined in the preliminary data is adopted until a new STRUCTURE command is encountered See also A 9 COMPONENT command Example STRUCTURE SHIP AY COMPONENT Command To define the component tree for a substructure MAXMIN run Not valid for a non substructured analysis COMPONENT sname tree Parameters COMPONENT keyword sname structure name as defined on the previous STRUCTURE command Alphanumeric 4 characters the first character must be alphabetic tree this is the path down the component tree from the given structure in Sname to the component which is being used for the MAXMIN stress processing Contains proprietary and confidential information of ANSYS Inc and
8. accessed by LOCO The format for backing files from MAXMIN is only readable by subseguent MAXMIN runs Example To save files necessary for further load enveloping SAVE LOCO FILES A 13 END Command To terminate the preliminary data Compulsory END Parameters END compulsory keyword Contains proprietary and confidential information of ANSYS Inc and its subsidiaries and affiliates Page A 9 MAXMIN User Manual Running MAXMIN Appendix B Running MAXMIN B 1 ASAS Files Required by MAXMIN MAXMIN operates on the files produced by the preceding ASAS LOCO and or MAXMIN runs and hence these must physically be present in the user s disc space for the program to be run successfully In all cases there will be the project file which contains information about all other files in the current set of analyses The name of this file is derived from the four character Project Name defined on all the PROJECT commands in the set For example if the Project Name is PRKZ the Project File will be PRKZ10 For each ASAS LOCO or MAXMIN analysis preceding this run with a SAVE LOCO FILES command in its preliminary data there will be a physical file containing the stress information from that analysis Again the physical file names are derived from the four character name defined on the FILES command Typically if the names used were STVK SOSY and TBSS then the physical files would be STVK35 SOSY35 and TBSS35 The information sto
9. component From structure STR2 and component CMP9 it is required to include all loadcases LOAD 1 2 3 LOAD 6 STRUCTURE STR2 Contains proprietary and confidential information of ANSYS Inc and its subsidiaries and affiliates Page 2 4 MAXMIN User Manual Data Formats COMPONENT STR2 CMP9 LOAD END 2 5 ELEMENT Selection Command A subset of the total number of elements within the run can be selected to be output using this command Each ELEMENT command contains a list of user element numbers The final ELEMENT command must carry the word END between the word ELEMENT and the user element number U ELEMENT END C elno 5 a Parameters ELEMENT keyword to denote the start of element selection END keyword last command of element set only elno list of element numbers Integer Notes The program default is that all elements are output if no ELEMENT command is present in the data 2 6 GROUP Selection Command A subset of the total number of groups within the run can be selected using this command Each GROUP command contains a list of group numbers The final group command must carry the word END between the word GROUP and the group number GROUP END groups cans CN aaa Parameters GROUP keyword to denote the start of group selection END keyword last command of group set only groups list of element numbers Integer Contains proprietary and confidential i
10. er the same Project Name GHPJ the three identifiers used on the runs being GD02 GD22 and GD12 SYSTEM DATA AREA 30000 PROJECT GHPJ FILES LOC1 JOB POST TITLE MAXMIN EXAMPLE 3 STRUCTURES CONTRIBUTING STRUCTURE GDO2 Contains proprietary and confidential information of ANSYS Inc and its subsidiaries and affiliates Page 3 1 MAXMIN User Manual Examples EWSTRUCTURE LOC1 PTIONS END ND o z tr ENT END 10 PUT END 2 RE GDO2 o D W H UO C ao ni E GD22 O D o Hg C Q ye E GD12 DTI O D oO tj Z Uro PE Ga TT GO SEP ae ye c Oo C ye o TE 3 3 Example 3 Multiple Use of MAXMIN for Simple ASAS Analyses This example illustrates the use of MAXMIN to process files of stress information from previous uses of MAXMIN itself 3 3 1 Original MAXMIN Run This run takes the files from an ASAS analysis Project Name GD12 and backing file name GD12 the user either gave the file name as GD12 or left it blank and hence it defaulted to the Project Name A NEWSTRUCTURE called YZLO is being created and the files will be saved SYSTEM DATA AREA 320000 PROJECT GD12 FILES YZLO JOB POST TITLE FIRST USAGE OF MAXMIN ON GD12 STRUCTURE STRUCTURE GD12 NEWSTRUCTURE YZLO OPTIONS END S AVE LOCO FILES END LOAD 5 OAD END 4 STOP 3 3 2 Second
11. eseressseessresseesseeeseeeessees 3 3 2 Second MAXMIN RUN ce NE i 3 4 Example 4 Substructured Usage of MAXMIN ee eeecceeeeececeeeeeeeeeeeeeteeeeneeeenes Appendix A Preliminary Data Deck for MAXMIN ssseeesesseeseeesersrrsesressrsrresresseseresresss Pecks APOC MC LLO i na a i LA Ru GU du uo A2 SYSTEM Command o aaa E Rd NC CG a aoe renee une Ar PROIECFCGmmdand ce GA n a aasien uch JOB Command a yd Ga od chi aetna oe Ne land AS EILES Commands ces eu asu TF Td ydd YNG Gyd FRI NCF Cd yR GYN CF yd O DF SUR AG LVEEF Command Gi n EG i AT FLOC Oman dae E Odd eU i CRY owe AS STRUCTURE IC Canned ss ss Ga Y Yf seed case O dn dn A 9 COMPONENT Command inesse Uyw yy E GR GAR eee Fd A 10 NEWSTRUCTURE Comniand 1954 i 45349157 Fr Sd dodd FARC HOSAN GYNAN SN Y CY ML Fd ATL OPTIONS Command ce GA YD DY E r NES Ale AN BC OMIM ANG ee Y Yd NN Y A13 END Command uei eadw GY YA YN le draccatenceedasceseaedsounaddessdseueasscceatasdusaceaspaccaes Appendix B Running MAXMIN 0 ec ceeccccssccecssececssececnsececnsccesssccesssceeessceessceseseeesneees B 1 ASAS Files Required by MAX MIN Y Y O yT RYG CF MOYN CO OG B 2 Saving Files Produced by MAXMIN ccssssssssscesssccsensscsensccscsaseecsecceeneseesneesees B 3 Running Instructions for MAXMIN oe eeeeeeseecssecneeeeseeeeseecaeceseesseeesaeecnaeenes Contains proprietary and confidential information of ANSYS Inc and its subsidiaries and affiliates MAXMIN User Manual Introducti
12. eyword to denote that loads from a different component are to be utilised This command is only used for substructure analyses but see below sname structure name identifying which existing structure is to be accessed from the project defined in the preliminary data for subsequent loadcases tree this is the path down the component tree from the given structure in Sname to the recovered component being used for the MAXMIN processing If processing a global structure run from a multilevel analysis and the component tree is not required use the STRUCTURE or MAXMIN command instead See example Section 3 4 LOAD compulsory keyword END keyword last command of loadcase set only case List of loadcase numbers Integer Notes 1 If no loadcase numbers are specified on a load command then the program defaults to include all loadcases 2 If results are drawn from more than one structure or MAXMIN run and use is made of the STRUCTURE MAXMIN or COMPONENT commands loadcase information is drawn from the currently defined structure or component until another STRUCTURE MAXMIN or COMPONENT command is defined However for clarity in such cases it is recommended that these commands should precede each LOAD command as appropriate See Example 2 Section 3 2 Example Suppose MAXMIN has so far been dealing with structure STR1 and component CMP7 as defined in the preliminary deck and that loadcases 1 2 3 and 6 are taken from this
13. its subsidiaries and affiliates Page A 6 MAXMIN User Manual Preliminary Data Deck for MAXMIN Notes 1 If the user is processing the global structure run in a substructure analysis use only the STRUCTURE command A 8 2 The loadcase information to be processed may be drawn from more than one component and this is achieved by respecifying a COMPONENT command within the MAXMIN data see Section 2 3 The component defined in the preliminary data is adopted until a new COMPONENT command is encountered Example COMPONENT SHIP PORT BULK A 10 NEWSTRUCTURE Command To define a new structure name associated with the results created by the current run NEWSTRUCTURE nsname Parameters NEWSTRUCTURE keyword nsname structure name associated with the results being created by the current run in order to identify these results from others in the project nsname must be unigue for this project Alphanumeric 4 characters Note If a component is being processed the resultant structure will be identified as nsname tree where tree is the existing path down the component tree from the original structure name to the component which is being processed e g If the original component is given by STRU CMP1 CMP2 and the new structure is STR2 then the new component results will be identified by STR2 CMP1 CMP2 Example eo reewwewewel en we oo y Contains proprietary and confidential information of ANSYS Inc
14. may differ with regard to the suppressions and loadcases It is important to note that each structure from which stresses are extracted must have been run under the same Project name MAXMIN reguires an ASAS style preliminary data block which is fully described in Appendix A The remaining data refer to the structure s component s original loadcases and previous MAXMIN analyses These data are all entered in an entirely free format style and are described fully in Section 2 Contains proprietary and confidential information of ANSYS Inc and its subsidiaries and affiliates Page 1 2 sogerjpgye pue sorrerpisgns SI pue OUJ SA SNV JO uoneuriogur epuopiguoo pue Amejouidoid sure uoc Sed Files Produced at Various Stages Fail Safe Runs i A First ASAS Basic Defective Run Project File Structure Structure eg ASJB10 1st ASAS RUN 2nd ASAS RUN 3rd ASAS RUN 4th ASAS RUN eg RUN135 eg RUN235 eg RUN335 eg RUN435 1st MXMN RUN 2nd MXMN RU 3rd MXMN RUN 4th MXMN RU eg MMR112 E eg MMR212 eg MMR312 eg MMR412 5th MXMN RUN eg MMR512 8th MXMN RUN eg MMR812 6th MXMN RUN eg MMR612 9th MXMN RUN eg MMR912 7th MXMN RUN eg MMR712 Figure 1 Flow Chart for MAXMIN Runs Tenue N 9SN NINXVIN uononpo nuJ MAXMIN User Manual Data Formats 2 Data Formats 2 1 General Principles The input data for MAXMIN are specified according to syntax diagrams similar to that shown below The conve
15. ment maxima and minima or the values related to each end of the element It must be noted that if comparison runs are conducted using axial elements the both ends option must be set consistently between runs MAXMIN prints the maximum and minimum stress levels for the elements reguested plus the loadcase which generates these stresses and the structure and component if multi level analysis on which the load is applied MAXMIN automatically prints the maximum and minimum stresses and their associated loadcases The user can however reguest up to the next 9 critical loadcases i e those loadcases which generate the next largest or smallest stress levels The percentage of the maximum and minimum stress values is printed out with each loadcase 1 1 Program Description The MAXMIN program operates on the files saved from one or more ASAS and or LOCO analyses and or previous MAXMIN runs These files are saved by adding a SAVE LOCO FILES command to the preliminary data block s of the original ASAS LOCO or MAXMIN runs The files contain the stresses together with various information about the original runs necessary for post processing Contains proprietary and confidential information of ANSYS Inc and its subsidiaries and affiliates Page 1 1 MAXMIN User Manual Introduction Results from one or more ASAS analyses may be selected providing that the structures or components under consideration have unigue user element numbers They
16. ne the amount of memory used for data by this run Optional Contains proprietary and confidential information of ANSYS Inc and its subsidiaries and affiliates Page A 2 MAXMIN User Manual Preliminary Data Deck for MAXMIN SYSTEM DATA AREA memory Parameters SYSTEM keyword DATA AREA keyword memory amount of memory in 4 byte words to be used by this run Typical values are between 30000 and 1000000 If the SYSTEM command is omitted a default value of 1000000 is used Examples SYSTEM DATA AREA 80000 A 3 PROJECT Command To define the project name for the current run Optional PROJECT pname Parameters PROJECT keyword pname project name for current run Alphanumeric 4 characters first character must be alphabetic Note All runs with the same project name access the same data base A project data base consists of one project file with a file name consisting of the 4 characters of pname with the number 10 appended which acts as an index to other files created under this project together with those other files Example PROJECT HIJK A 4 JOB Command To define the type of analysis being performed Compulsory Contains proprietary and confidential information of ANSYS Inc and its subsidiaries and affiliates Page A 3 MAXMIN User Manual Preliminary Data Deck for MAXMIN JOB POST Parameters JOB keyword POST keyword Example JOB POST A 5 FILES Command
17. nformation of ANSYS Inc and its subsidiaries and affiliates Page 2 5 MAXMIN User Manual Data Formats Notes The program default is that all groups are output if no GROUP command is present in the data 2 7 OUTPUT Selection Command The program calculates the maximum and minimum stresses plus the 9 next most critical loadcases for each stress This command allows a given subset of the stresses for 10 cases to be output As only one OUTPUT command is reguired this command must carry the word END between the word OUTPUT and the number of output cases reguested OUTPUT END ncrit Parameters OUTPUT keyword to denote that the user wishes to define the number of critical cases for output END compulsory keyword ncrit number of cases to be output Number of cases reguested must be less than or egual to 10 Integer Note If no OUTPUT command is present the program outputs only the single maximum and minimum cases If more cases are requested than exist in the preceding analyses values of minus or plus 10 will appear in the maxima and minima respectively for the non existent cases 2 8 STOP Command The final command of the MAXMIN data must always be the STOP command STOP Parameters STOP compulsory keyword Contains proprietary and confidential information of ANSYS Inc and its subsidiaries and affiliates Page 2 6 MAXMIN User Manual Examples 3 Examples 3 1 Example 1 Simple ASAS Analysis Thi
18. ntions adopted are described in the following pages KEYWORD alpha integer real The sequence of the input data follows the vertical line down the left hand side of the page Each horizontal branch represents a possible input instruction Input instructions are composed of keywords shown in upper case numerical values or alphanumerics shown in lower case characters and special symbols Each item in the list is separated from each other by a comma or one or more blank spaces An input line must not be longer than 80 characters Numerical values have to be given in one of two forms i If an integer is required a decimal point must not be supplied ii Ifa real number is required the decimal point may be omitted if the value is a whole number Exponent formats may be used where real numbers are required For example 0 004 4 0E 3 4 0D 3 are equivalent similarly 410 0 410 4 10E2 are the same Alphanumerics must begin with an alpha character A Z The letters A Z may be supplied in either upper or lower case but no distinction is made between the upper and lower case form Hence A is assumed identical with a B with b and so on For example CASE are all permissible alphanumeric strings STRI END also COMB are all identical strings Comb comb Contains proprietary and confidential information of ANSYS Inc and its subsidiaries and affiliates Page 2 1 MAXMIN User Man
19. on MAXMIN Find Maximum and Minimum Element Stress Levels 1 Introduction The MAXMIN program permits users to access the stress output files from ASAS or the identically formatted files from LOCO and determine the maximum and minimum stress levels in the structure for those loadcases reguested by the user which may be a subset of the total loadcases in the ASAS or LOCO analysis The facility exists to save the backing file used by MAXMIN for further use The user can output a selected subset of the elements within the structure or select given groups to be output Additionally the user can compare successive runs on a structure by reading the stress file for the later analysis and comparing the values with the MAXMIN filed values from a preceding analysis Included within this is the feature to do fail safe comparison analyses If an initial run is conducted with a complete structure and a MAXMIN file produced then the subseguent comparison runs may have elements omitted If this option is exercised then the structure and defective derivatives thereof must have unigue user element numbers defined in the element topology data of the ASAS analyses There is no theoretical restriction on the number of times MAXMIN may be run on a structure or its derivatives An example of the possibilities is shown in Figure 1 Another user option included is the ability to produce output for the axial elements with either the overall ele
20. red in each file will depend on the form of the run producing the output The stresses may relate to a single step analysis of a structure or to the results associated with elements at any level in a substructured analysis Provided that the user has the reguisite files on disc the program will handle them in a transparent manner B 2 Saving Files Produced by MAXMIN MAXMIN uses files in the same way as ASAS and a new physical file of the maximum and minimum stresses will be produced For example this file will be named YYYY35 where YYYY is the four character identifier on the FILES command in the MAXMIN preliminary data This physical file may be saved and hence used for further post processing by including a SAVE command in the preliminary data of the MAXMIN run If this command is absent then the file will not be saved B 3 Running Instructions for MAXMIN See the appendices in the ASAS User Manual for details on how to run any of the programs in the ASAS suite Contains proprietary and confidential information of ANSYS Inc and its subsidiaries and affiliates Page B 1
21. s and affiliates MAXMIN User Manual Update Sheet for Version 12 April 2009 Modifications The following modifications have been incorporated Section Page s Update Addition Explanation All All Update Conversion to Microsoft Word format Contains proprietary and confidential information of ANSYS Inc and its subsidiaries and affiliates MAXMIN User Manual Contents TABLE OF CONTENTS T gt JnfroductiOll censere LS eas CYFR FN BO CW DU Dn FEN OAN Fo FFF CYN FF dd 1 4 Program Description ri ee wu dd dw FF Fedr GN CY On gon GN S dd 25 Data POrmats es Ga Ru Yn aoa oa CN ws 21s General Principles aeiee enis a adu Y GU nan YD GR AY 2 1 1 SDecIal Symbols ce GYF O YNA ROF OFF 2 2 Preliminary Data Y Y GN FFRANC US CG Na FF 23 MAAM N PVA Me veins VA tated i RR A GA 2 4 LOADCASE sclccouonComnands es a y Gr yD o GN wdd 2 5 ELEMENT Selection Comnmand 55 v 61415 55g ea YN FA F GO WN Y LD GAN CY SNRO A NN GFTN 2 6 GROUP Selection oma sc i id Ydd y y YF edu A 2 OUTPUT Selection Command eni a FY Od Dia TORF Command ee Y Y DF 3s Examples uan ie dd ga Md drdd Fe gasses dd GG Fydden 3 1 Example 1 Simple ASAS Analysis 000 0 ceecccesecesssceceeccesssececsscceessccessceeensceesnes 3 2 Example 2 Comparison of Loadcases from Three Individual Analyses 3 3 Example 3 Multiple Use of MAXMIN for Simple ASAS Analyses 3 3 1 Original MAXMIN Run s ssssssssssessssssesssesssseesssressersser
22. s example illustrates the usage of MAXMIN to select three loadcases from an ASAS run and to compute the maximum and minimum stresses for all elements and all groups in the structure Only one set of ASAS files is accessed The Project Name for both the ASAS and MAXMIN runs is JACK The four character backing file name of the ASAS run was JAC1 The MAXMIN run produces new files with the identifier JAC2 Note that in this instance a single ASAS analysis the STRUCTURE name is also taken as the four character backing file identifier JAC1 The NEWSTRUCTURE name becomes JAC2 The files used in this run are reguired for further post processing and hence a SAVE card is included SYSTEM DATA AREA 30000 PROJECT JACK JOB POST FILES JAC2 TITLE AIRPLANE LANDING CASES STRUCTURE JACI NEWSTRUCTURE JAC2 SAVE LOCO FILES OPTIONS END OAD END 1 2 3 3 2 Example 2 Comparison of Loadcases from Three Individual Analyses This example takes three loadcases one each from three different analyses and computes the maximum and minimum stresses for the 2 most critical loadcases for user element number 10 Note that the first loadcase is taken from structure GDO2 as defined in the preliminary deck The Project Name is GHPJ and the files used in this MAXMIN analysis are identified by LOC1 As there is no SAVE card no further post processing will be possible Note that all three structures must have been run und
23. ual However 3BMD are examples of inadmissible alphanumeric strings 5BL Alphanumeric strings must not include any special symbols see below Zoli Special Symbols The following is a list of characters which have a special significance to the MAXMIN input An asterisk is used to define the beginning of a comment whatever follows on the line will not be interpreted It may appear anywhere on the line any preceding data will be processed as normal For example THIS IS A COMMENT FOR THE WHOLE LINE ELEMENT 5 10 THIS IS A COMMENT FOR PART OF A LINE single guotes are used to enclose some text strings which could contain otherwise inadmissible characters The guotes are placed at each end of the string They may also be used to provide in line comments between data items on a given line For example STRUCTURE As used for design study STRU A comma or a blank will act as a delimiter between items in the line For example 5 10 15 isthesameas 5 10 15 Note that two commas together signify that an item has been omitted This may be permissible for certain data blocks For example yg LS Unless otherwise stated in the section describing the data block omitted numerical values are Zero 2 2 Preliminary Data This data block at the head of the MAXMIN data contains the JOB TITLE TEXT SAVE OPTIONS etc commands and is fully described in Appendix A 2 3 MAXMIN Data
24. urnished by ANSYS Inc its subsidiaries or affiliates under a software license agreement that contains provisions concerning non disclosure copying length and nature of use compliance with exporting laws warranties disclaimers limitations of liability and remedies and other provisions The software products and documentation may be used disclosed transferred or copied only in accordance with the terms and conditions of that software license agreement ANSYS Inc is certified to ISO 9001 2008 U S Government Rights For U S Government users except as specifically granted by the ANSYS Inc software license agreement the use duplication or disclosure by the United States Government is subject to restrictions stated in the ANSYS Inc software license agreement and FAR 12 212 for non DOD licenses Third Party Software The products described in this document contain the following licensed software that requires reproduction of the following notices Formula One is a trademark of Visual Components Inc The product contains Formula One from Visual Components Inc Copyright 1994 1995 All rights reserved See the legal information in the product help files for the complete Legal Notice for ANSYS proprietary software and third party software If you are unable to access the Legal Notice please contact ANSYS Inc Published in the U S A Contains proprietary and confidential information of ANSYS Inc and its subsidiarie